input
stringclasses
1 value
instruction
stringlengths
222
3.65k
output
stringlengths
193
367
category
stringclasses
1 value
index
stringclasses
1 value
fileName
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "基板搬送確認6", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "4.ジグステーションを取り外し を押しながら④を押す", "1. を押しながら①を押す", "2. ②を押す", "3.ノズルを取り外し を押しながら③を押す", "正常に終了すること", "WERP-F013-105" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "エラー無き事", "Method": "目視", "RecordMethod": "WERP-F013-105", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "2㎜", "ToolOther": "81cN・m", "WorkName": "チャートマークブロック取付", "WorkItems": [ "1. ①をBOLT で取付け" ], "WorkPoints": [ "前後に軽量16ノズルヘッドV3Aがある場合はそれぞれ取付のこと", "面取りが右側" ], "Tolks": [ "締付トルク 81cN・m" ], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "81cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "有線ハンディスキャナ確認1", "WorkItems": [ "1. 有線ハンディスキャナの確認を行う" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "設備の電源をOFFにし、有線ハンディスキャナを接続し電源をONする。", "サービスマンかエンジニアモードに切り替えた後、マシン調整を押す" ] }
{ "QualityItem": "画面操作", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "作業指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "有線ハンディスキャナ確認2", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "WERP-F013-103", "InspectionItems": [ "検査表①:①動作確認" ], "WorkTypes": [], "Words": [ "下記画面表示後、有線ハンディスキャナで組立/調整(オプション)検査表の『CHECK OK』バーコードを読み取る。", "読み取り後、下記画面『CHECK OK』が表示される事を確認する。", "再度有線ハンディスキャナで検査表『CHECK NG』バーコードを読み取り、下記画面『CHECK NG』が表示される事を確認する。", "入力確認のアドレス0003を表示させ、有線ハンディスキャナで『CHECK OK』を読み込んだ時、 ビット2がONする事を確認する。R側も同様に確認する事。", "製品検査表 組立/調整(オプション) WHSに記入(1のオプション設定はーで消す)", "検査表①:②I/O MAP スキャナーリクエスト", "WERP-F013-103" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "作業指示通り出来ている事", "Method": "目視", "RecordMethod": "WERP-F013-103", "Other": "有線ハンディスキャナオプション", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "有線ハンディスキャナ確認2", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "下記画面表示後、有線ハンディスキャナで組立/調整(オプション)検査表の『CHECK OK』バーコードを読み取る。", "読み取り後、下記画面『CHECK OK』が表示される事を確認する。", "再度有線ハンディスキャナで検査表『CHECK NG』バーコードを読み取り、下記画面『CHECK NG』が表示される事を確認する。", "入力確認のアドレス0003を表示させ、有線ハンディスキャナで『CHECK OK』を読み込んだ時、 ビット2がONする事を確認する。R側も同様に確認する事。", "製品検査表 組立/調整(オプション) WHSに記入(1のオプション設定はーで消す)", "検査表①:①動作確認", "検査表①:②I/O MAP スキャナーリクエスト", "WERP-F013-056" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "作業指示通り出来ている事", "Method": "目視", "RecordMethod": "WERP-F013-056", "Other": "有線ハンディスキャナオプション", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "エージング動作1", "WorkItems": [ "1. 規定時間のエージング動作を行う" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "押す", "エンジニアモードより(サービスマン、オペレーターでも可)", "押す", "押す", "稼動情報のデータをクリアする", "押す", "押す", "エージングデータをSDカードより読み込む", "押す", "押す", "データ次項、前項操作", "押す", "本画面は12-12のデータですが他の仕様も操作内容は同じです。(仕様と合ったデータを選択する)", "N_AGING", "フロントヘッドタイプ16、8、2", "リアヘッドタイプ16、8、2", "エージングデータ名の意味", "N-" ] }
{ "QualityItem": "画面操作", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "作業指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "エージング動作2", "WorkItems": [ "1. ①『生産』を押す", "2. ②『調整用ソフトスイッチ』を押す", "3. ③『装着・幅調整・吸着・基板認識・部品認識』をON、 それ以外を全てOFFにする", "1. ①『生産』を押す", "2. 操作パネルの を押しながら を押し 生産を開始する", "3. ③認識率の警告が表示されるので 『はい』を押す" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "START SW", "ENABLING SW", "-段取り替え(データロード)-", "-エージング開始-" ] }
{ "QualityItem": "画面操作", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "作業指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "エージング動作3", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "STOP SWを押しエージング動作を停止させる", "押す", "押す", "押してSDカードに記録させプリントアウトし帳票に貼付ける。", "-設定変更(認識OK率リセット)-", "3. ⑧確認画面が出るので 『はい』 を押す", "1. ①『マシン』 →②『設定』 →③『マルチ認識カメラ』 →④『動作パラメータ』 →⑤『判定』 →⑥『認識OK率』 の項目No の順番にボタンを押す", "2. ⑦『リセット』 を押す" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "エラー無き事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "マルチ2Dノズル認識高さ変更仕様設定", "WorkItems": [ "1. サービスマンモードから下記の手順でソフトスイッチ設定画面を開く", "2. マルチ2Dノズル認識高さ変更仕様を『ON』にする", "3. 設定を保存し、キャリブレーションを実施する" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:2.ソフトSWの設定確認" ], "WorkTypes": [], "Words": [ "削除", "WDQB-F013-104" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りに設定されている事", "Method": "目視(画面表示)", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション(OP)設定「自動下受けピン」", "WorkItems": [ "1.オプション設定画面にて、下受けピン自動交換を『ON』にする" ], "WorkPoints": [ "※治具ステーション前に設定を実施ていないと、自動下受けピン時のキャリブレーションが実施されないので注意すること" ], "Tolks": [], "InspectionNo": "WDQB-F013-103", "InspectionItems": [ "検査表①:SPAC 2、ソフトスイッチの確認" ], "WorkTypes": [], "Words": [ "WDQB-F013-103" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りに設定されている事", "Method": "目視(画面表示)", "RecordMethod": "WDQB-F013-103", "Other": "オプション仕様", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション高速化設定", "WorkItems": [ "1. サービスマンモードから下記の手順でソフトスイッチ設定画面を開く", "2. キャリブレーションXY軸速度UPを『ON』にする", "3. ホームに戻り、キャリブレーションを実施する" ], "WorkPoints": [ "キャリブレーション終了後に設定を『OFF』すること。または、マシン電源OFF⇒ONする。(初期値『OFF』に戻る)" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "削除" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りに設定されている事", "Method": "目視(画面表示)", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP1『ヘッドカメラXY原点』", "WorkItems": [ "3. を押しながら④を押す", "1. ①②を押す", "2. を押しながら③を押す", "4. ⑤を押す", "5. ⑥を押す", "6. を押しながら⑦を押す", "7. R側も2~6の手順で実施する" ], "WorkPoints": [ "OK:画面切替時に「データを保存しますか?」を表示→次の計測を行う", "NG:画面切替時に「リミット値を超えていますので保存できません」を表示→計測条件(ティーチ)条件の見直し 再度計測(ティーチ)を行う", "規格値カメラ角度:±0.2°XY原点:±2.0㎜ カメラスケール:0.0096~0.0104" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "カメラ角度±0.2°以内", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP1『ヘッドカメラXY原点』", "WorkItems": [ "3. を押しながら④を押す", "1. ①②を押す", "2. を押しながら③を押す", "4. ⑤を押す", "5. ⑥を押す", "6. を押しながら⑦を押す", "7. R側も2~6の手順で実施する" ], "WorkPoints": [ "OK:画面切替時に「データを保存しますか?」を表示→次の計測を行う", "NG:画面切替時に「リミット値を超えていますので保存できません」を表示→計測条件(ティーチ)条件の見直し 再度計測(ティーチ)を行う", "規格値カメラ角度:±0.2°XY原点:±2.0㎜ カメラスケール:0.0096~0.0104" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "検査表①:キャリブレーション", "WDQB-F013-104" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "XY原点±20㎜以内", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP1『ヘッドカメラXY原点』", "WorkItems": [ "3. を押しながら④を押す", "1. ①②を押す", "2. を押しながら③を押す", "4. ⑤を押す", "5. ⑥を押す", "6. を押しながら⑦を押す", "7. R側も2~6の手順で実施する" ], "WorkPoints": [ "OK:画面切替時に「データを保存しますか?」を表示→次の計測を行う", "NG:画面切替時に「リミット値を超えていますので保存できません」を表示→計測条件(ティーチ)条件の見直し 再度計測(ティーチ)を行う", "規格値カメラ角度:±0.2°XY原点:±2.0㎜ カメラスケール:0.0096~0.0104" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "検査表①:キャリブレーション", "WDQB-F013-104" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "カメラスケール規格0.0096~0.0104", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "面補正治具", "Size": "", "ToolOther": "N610124226AB", "WorkName": "キャリブレーション:STEP1『面補正XY1』", "WorkItems": [ "4. 右側終了後、面補正治具左側へ設置する", "2. 面補正治具を設置する", "6. ⑤を押す", "4. 右側終了後、面補正治具左側へ設置する", "2. 面補正治具を設置する", "6. ⑤を押す" ], "WorkPoints": [ "面補正治具の右端面を基準穴の中心にあわせる面補正治具を固定レールに押し当てる", "面補正治具の左端面を基準穴の中心にあわせる面補正治具を固定レールに押し当てる", "面補正治具の右端面を基準穴の中心にあわせる面補正治具を固定レールに押し当てる", "面補正治具の左端面を基準穴の中心にあわせる面補正治具を固定レールに押し当てる" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "拡大", "押し当て", "押し当て", "拡大", "拡大", "押し当て", "押し当て", "拡大" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "エラー無き事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "面補正治具", "Size": "", "ToolOther": "N610124226AA", "WorkName": "キャリブレーション:STEP1『面補正XY2』", "WorkItems": [ "8. 『ガラス基板を取り除いてください』の表示がでたら、 面補正治具を取り出す", "9. を押しながら⑦を押す", "7. ⑥を押す" ], "WorkPoints": [ "画像はデュアルコンベア仕様時の表示", "規格値 面補正XY:±0.5㎜", "画像はデュアルコンベア仕様時のみ実施" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "面補正XY:±0.5㎜", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP2『ヘッド/面補正Z1』", "WorkItems": [ "2. ヘッドにノズルを取付ける", "3. を押しながら②を押す", "4. を押しながら③を押す", "5. を押しながら④を押す", "1. を押しながら①を押す" ], "WorkPoints": [ "使用ノズル16・12ノズル:230CSN 8ノズル:230CN 3ノズル:1002N", "ヘッド仕様に合わせて取付けの事", "全てOKになっている事を確認する", "5番ノズルポジションにノズルがある事を確認する" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "画像は16ノズルヘッド", "規格値16&12ノズル:±0.5㎜ 8ノズル:-1.85㎜~5.85㎜ 3ノズル: 0㎜~12㎜", "WDQB-F013-104" ] }
{ "QualityItem": "高さ確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "・12/16ノズル±0.5㎜・8ノズル-1.85~5.85㎜・3ノズル0~12㎜", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP2『ヘッド/面補正Z1』", "WorkItems": [ "2. ヘッドにノズルを取付ける", "3. を押しながら②を押す", "4. を押しながら③を押す", "5. を押しながら④を押す", "1. を押しながら①を押す" ], "WorkPoints": [ "使用ノズル16・12ノズル:230CSN 8ノズル:230CN 3ノズル:1002N", "ヘッド仕様に合わせて取付けの事", "全てOKになっている事を確認する", "5番ノズルポジションにノズルがある事を確認する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "画像は16ノズルヘッド", "検査表①:キャリブレーション", "規格値16&12ノズル:±0.5㎜ 8ノズル:-1.85㎜~5.85㎜ 3ノズル: 0㎜~12㎜", "WDQB-F013-104" ] }
{ "QualityItem": "高さ確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "・12/16ノズル±0.5㎜・8ノズル-1.85~5.85㎜・3ノズル0~12㎜", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP2『ヘッド/面補正Z2』", "WorkItems": [ "6. を押しながら⑤を押す", "7. ⑥を押す", "8. ⑦を押す", "9. ⑧を押す", "7. R側も1~9の手順で実施する" ], "WorkPoints": [ "規格値 全ノズル:±0.5㎜" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション", "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "面補正Z規格±0.5㎜", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP2『実装位置/コンベア1』", "WorkItems": [ "1. ①を押し、 を押しながら②を押す", "3. を押しながら④を押す", "4. を押しながら⑤を押す", "2. 画面指示従って治具を取付け、③を押す", "5. ⑥を押す" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "-", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "エラー無き事(正常停止)", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP2『実装位置/コンベア2』", "WorkItems": [ "6. ⑦を押す", "7. ⑧を押す" ], "WorkPoints": [ "規格値 停止位置:±0.5㎜ 高さ:±1.0㎜" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "停止位置規格±0.5㎜", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP2『実装位置/コンベア2』", "WorkItems": [ "6. ⑦を押す", "7. ⑧を押す" ], "WorkPoints": [ "規格値 停止位置:±0.5㎜ 高さ:±1.0㎜" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "検査表①:キャリブレーション", "WDQB-F013-104" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "高さ規格±1.0㎜", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ロードセル(荷重測定治具)", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP2『搭載荷重測定1』(3ノズルヘッドのみ)", "WorkItems": [ "1. を押しながら①を押す", "2. を押しながら②を押す", "3. 各治具を設置する" ], "WorkPoints": [ "基板クランプ端面に合わせる", "基板クランプ端面に合わせる", "右 → 左流れ", "左 → 右流れ", "共 通", "配線が干渉しない様引き回しを行う", "配線が干渉しない様引き回しを行う", "※台車を設備に接続し、実施すること" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "電源接続", "削除" ] }
{ "QualityItem": "設置確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "配線が干渉しない用にセットされている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル荷重測定治具", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP2『搭載荷重測定2』(3ノズルヘッドのみ)", "WorkItems": [ "4. を押しながら③を押す", "5. ④を押しキャリブレーションを行うヘッドを選択する", "6. を押しながら⑤を押す", "7. 測定を行うヘッドにノズルを取付け、 を押しながら⑥を押す", "8. を押しながら⑦を押す" ], "WorkPoints": [ "ロードセルメーターは、MAX値では正確な測定ができないため、現在値で測定する事", "計測中、荷重測定治具の表示部を確認しておく" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "削除" ] }
{ "QualityItem": "荷重計測", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "表示部の数値を記録する", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル荷重測定治具", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP2『搭載荷重測定3』(3ノズルヘッドのみ)", "WorkItems": [ "11. を押しながら⑨を押す", "9. ⑧を押す", "10. 治具にて読み取った数値を入力する", "12. ⑩を押す", "13. 治具にて読み取った数値を入力する", "14. を押しながら⑪を押す" ], "WorkPoints": [ "計測中、荷重測定治具の表示部を確認しておく", "計測中、荷重測定治具の表示部を確認しておく" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "削除" ] }
{ "QualityItem": "荷重計測", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "表示部の数値を記録する", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル荷重測定治具", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP2『搭載荷重測定4』(3ノズルヘッドのみ)", "WorkItems": [ "15. ⑫を押す", "16. 治具にて読み取った数値を入力する", "18. ⑭を押す", "17. ⑬を押し、14~16の手順を実施する", "19. ⑮を押しキャリブレーションを行うヘッドを選択し、6~18の手順で実施する", "20. ⑯を押す" ], "WorkPoints": [ "計測中、荷重測定治具の表示部を確認しておく", "計測中、荷重測定治具の表示部を確認しておく", "入力値が0.5 N以下の場合:手順17へ入力値が0.5 N以上の場合:手順18へ" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "入力設定", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りに入力されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル荷重測定治具", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP2『搭載荷重測定5』(3ノズルヘッドのみ)", "WorkItems": [ "21. ⑰を押す", "24. 治具を取り外し、 を押しながら⑳を押す", "23. ノズルを取り外し、 を押しながら⑲を押す", "22. を押しながら⑱を押す", "25. R側も1~23の手順で実施する" ], "WorkPoints": [ "計測中、荷重測定治具の表示部を確認しておく", "規格値 A:4.5 ~ 5.5 B:1 ~ 10", "R側を続けて行う場合は、取り外さなくてもよい" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "削除", "WDQB-F013-104" ] }
{ "QualityItem": "荷重計測", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "A:4.5~5.5B:1~10", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ラインカメラ治具(高速ヘッド)", "Size": "", "ToolOther": "N610071657AA", "WorkName": "キャリブレーション:STEP3『マルチ認識カメラ1』", "WorkItems": [ "1. ①を押し、 を押しながら②を押す", "2. 画面指示従って治具を取付け、 を押しながら③を押す", "3. を押しながら④を押す", "4. 画面指示従って治具を取付け、 を押しながら⑤を押す", "5. 画面指示従って治具を取付け、 を押しながら⑥を押す" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "画面指示通りに取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ラインカメラ治具(多機能ヘッド)", "Size": "", "ToolOther": "N610004070AB", "WorkName": "キャリブレーション:STEP3『マルチ認識カメラ1』", "WorkItems": [ "1. ①を押し、 を押しながら②を押す", "2. 画面指示従って治具を取付け、 を押しながら③を押す", "3. を押しながら④を押す", "4. 画面指示従って治具を取付け、 を押しながら⑤を押す", "5. 画面指示従って治具を取付け、 を押しながら⑥を押す" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "画面指示通りに取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ラインカメラ治具(高速ヘッド)", "Size": "", "ToolOther": "N610071657AA", "WorkName": "キャリブレーション:STEP3『マルチ認識カメラ2』", "WorkItems": [ "10. ⑪を押す", "7. を押しながら⑧を押す", "9. ⑩を押す", "11. R側も1~10の手順で実施する", "8. 画面指示従って治具を取付け、 を押しながら⑨を押す", "6. を押しながら⑦を押す" ], "WorkPoints": [ "規格値 ヘッドθ原点:-180°~180° カメラオフセット:X/Y=±0.8㎜ θ=±0.2°" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション", "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "規格確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "ヘッドθ原点-180°~180°", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ラインカメラ治具(多機能ヘッド)", "Size": "", "ToolOther": "N610004070AB", "WorkName": "キャリブレーション:STEP3『マルチ認識カメラ2』", "WorkItems": [ "10. ⑪を押す", "7. を押しながら⑧を押す", "9. ⑩を押す", "11. R側も1~10の手順で実施する", "8. 画面指示従って治具を取付け、 を押しながら⑨を押す", "6. を押しながら⑦を押す" ], "WorkPoints": [ "規格値 ヘッドθ原点:-180°~180° カメラオフセット:X/Y=±0.8㎜ θ=±0.2°" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション", "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "規格確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "カメラオフセットX・Y=±0.8㎜", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3『マルチ認識カメラ2』", "WorkItems": [ "10. ⑪を押す", "7. を押しながら⑧を押す", "9. ⑩を押す", "11. R側も1~10の手順で実施する", "8. 画面指示従って治具を取付け、 を押しながら⑨を押す", "6. を押しながら⑦を押す" ], "WorkPoints": [ "規格値 ヘッドθ原点:-180°~180° カメラオフセット:X/Y=±0.8㎜ θ=±0.2°" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "検査表①:キャリブレーション", "検査表①:キャリブレーション", "WDQB-F013-104" ] }
{ "QualityItem": "規格確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "カメラオフセットθ=±0.2°", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "キャリブレーション治具(16/12/8N用)キャリブレーション治具(3N用)", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3『ビルドアップ1』", "WorkItems": [ "3. 画面指示従って治具を取付け、 を押しながら④を押す", "1. ①を押し、 を押しながら②を押す", "2. 画面指示従って治具を取付け、 を押しながら③を押す", "4. を押しながら⑤を押す", "5. 下記メッセージが表示がされるので、表示に従う" ], "WorkPoints": [ "キャリブレーション継続中なので、電源は落とさ無い事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "画面指示通りに取付出来ている事エラー無き事(正常停止)", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズルジグノズルジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3『ビルドアップ1』", "WorkItems": [ "3. 画面指示従って治具を取付け、 を押しながら④を押す", "1. ①を押し、 を押しながら②を押す", "2. 画面指示従って治具を取付け、 を押しながら③を押す", "4. を押しながら⑤を押す", "5. 下記メッセージが表示がされるので、表示に従う" ], "WorkPoints": [ "キャリブレーション継続中なので、電源は落とさ無い事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "画面指示通りに取付出来ている事エラー無き事(正常停止)", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "キャリブレーションキャリブレーション照明輝度ジグ", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3『ビルドアップ2』", "WorkItems": [ "6. 下記表示を確認し、支持通りの手順を押す", "7. R側も1~6の手順で実施する", "9. 治具を取り外した後、 を押しながら⑨を押す", "8. を押しながら⑧を押す", "10. ⑩を押す", "11. SDを抜いて、素早く再起動を行う" ], "WorkPoints": [ "R側:ビルドアップキャリブがある場合は⑥を押し手順7へ", "R側:ビルドアップキャリブがない場合は⑦を押し手順8へ", "R側:ビルドアップキャリブがない場合のみ表示する" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "エラー無き事(正常停止)", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズルジグノズルジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3『ビルドアップ2』", "WorkItems": [ "6. 下記表示を確認し、支持通りの手順を押す", "7. R側も1~6の手順で実施する", "9. 治具を取り外した後、 を押しながら⑨を押す", "8. を押しながら⑧を押す", "10. ⑩を押す", "11. SDを抜いて、素早く再起動を行う" ], "WorkPoints": [ "R側:ビルドアップキャリブがある場合は⑥を押し手順7へ", "R側:ビルドアップキャリブがない場合は⑦を押し手順8へ", "R側:ビルドアップキャリブがない場合のみ表示する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "検査表①:キャリブレーション", "WDQB-F013-104" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "エラー無き事(正常停止)", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグステーション照明輝度ジグジグ部品", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3『ジグステーション1』", "WorkItems": [ "1. ①を押し、 を押しながら②を押す", "3. ジグステーションを設置する", "4. を押しながら④を押す", "5. を押しながら⑤を押す", "2. を押しながら③を押す", "6. 画面指示従ってノズルを取付け、⑥を押す" ], "WorkPoints": [ "ジグステーション端面をガイドのマークセンターに合わせる", "右 → 左流れ", "左 → 右流れ" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "SWをONする" ] }
{ "QualityItem": "設置確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りの位置にセットされている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズルジグノズルジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3『ジグステーション1』", "WorkItems": [ "1. ①を押し、 を押しながら②を押す", "3. ジグステーションを設置する", "4. を押しながら④を押す", "5. を押しながら⑤を押す", "2. を押しながら③を押す", "6. 画面指示従ってノズルを取付け、⑥を押す" ], "WorkPoints": [ "ジグステーション端面をガイドのマークセンターに合わせる", "右 → 左流れ", "左 → 右流れ" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "SWをONする" ] }
{ "QualityItem": "設置確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りの位置にセットされている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグステーションPIP照明輝度ジグジグ部品", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3『ジグステーション1』(PIP照明仕様)", "WorkItems": [ "1. ①を押し、 を押しながら②を押す", "3. ジグステーションを設置する", "4. を押しながら④を押す", "5. を押しながら⑤を押す", "2. を押しながら③を押す", "6. 画面指示従ってノズルを取付け、⑥を押す" ], "WorkPoints": [ "ジグステーション端面をガイドのマークセンターに合わせる", "右 → 左流れ", "左 → 右流れ" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "SWをONする", "3ノズルヘッド限定仕様" ] }
{ "QualityItem": "設置確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りの位置にセットされている事", "Method": "目視", "RecordMethod": "-", "Other": "PIPオプション", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3『ジグステーション1』(PIP照明仕様)", "WorkItems": [ "1. ①を押し、 を押しながら②を押す", "3. ジグステーションを設置する", "4. を押しながら④を押す", "5. を押しながら⑤を押す", "2. を押しながら③を押す", "6. 画面指示従ってノズルを取付け、⑥を押す" ], "WorkPoints": [ "ジグステーション端面をガイドのマークセンターに合わせる", "右 → 左流れ", "左 → 右流れ" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "SWをONする", "3ノズルヘッド限定仕様" ] }
{ "QualityItem": "設置確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りの位置にセットされている事", "Method": "目視", "RecordMethod": "-", "Other": "PIPオプション", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグステーション照明輝度ジグジグ部品ジグノズルジグノズルジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3『ジグステーション2』", "WorkItems": [ "7. を押しながら⑦を押す", "8. ⑧を押す", "9. ⑨を押す", "10. ノズルをチェンジャーから取り外したら⑩を押す", "11. ジグステーションを取り外してから⑪を押す", "8. R側も1~11の手順で実施する" ], "WorkPoints": [ "規格値 スキャン位置:(標準) ±5㎜ (ノズル) ±0.1㎜ チェンジャ高さ:±0.5㎜ 角度毎/角度毎認識毎オフセット:±0.1㎜ 装着/認識/計測回転中心:±0.2㎜ マルチ認識カメラオフセット:-60~-20 マルチ認識カメラゲイン:0~4 ヘッドカメラオフセット:-15~15 ヘッドカメラゲイン:0~3", "R側を続けて実施する場合は取り外し不要" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション", "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "スキャン位置", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "スキャン位置:(標準)±5㎜(ノズル)±0.1㎜", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグステーション照明輝度ジグジグ部品ジグノズルジグノズルジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3『ジグステーション2』", "WorkItems": [ "7. を押しながら⑦を押す", "8. ⑧を押す", "9. ⑨を押す", "10. ノズルをチェンジャーから取り外したら⑩を押す", "11. ジグステーションを取り外してから⑪を押す", "8. R側も1~11の手順で実施する" ], "WorkPoints": [ "規格値 スキャン位置:(標準) ±5㎜ (ノズル) ±0.1㎜ チェンジャ高さ:±0.5㎜ 角度毎/角度毎認識毎オフセット:±0.1㎜ 装着/認識/計測回転中心:±0.2㎜ マルチ認識カメラオフセット:-60~-20 マルチ認識カメラゲイン:0~4 ヘッドカメラオフセット:-15~15 ヘッドカメラゲイン:0~3", "R側を続けて実施する場合は取り外し不要" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション", "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "チェンジャ高さ", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "チェンジャ高さ:±0.5㎜", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグステーション照明輝度ジグジグ部品ジグノズルジグノズルジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3『ジグステーション2』", "WorkItems": [ "7. を押しながら⑦を押す", "8. ⑧を押す", "9. ⑨を押す", "10. ノズルをチェンジャーから取り外したら⑩を押す", "11. ジグステーションを取り外してから⑪を押す", "8. R側も1~11の手順で実施する" ], "WorkPoints": [ "規格値 スキャン位置:(標準) ±5㎜ (ノズル) ±0.1㎜ チェンジャ高さ:±0.5㎜ 角度毎/角度毎認識毎オフセット:±0.1㎜ 装着/認識/計測回転中心:±0.2㎜ マルチ認識カメラオフセット:-60~-20 マルチ認識カメラゲイン:0~4 ヘッドカメラオフセット:-15~15 ヘッドカメラゲイン:0~3", "R側を続けて実施する場合は取り外し不要" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "検査表①:キャリブレーション", "検査表①:キャリブレーション", "WDQB-F013-104" ] }
{ "QualityItem": "規格確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "チェンジャ高さ:±0.5㎜", "Method": "目視(画面表示)", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグステーション照明輝度ジグジグ部品ジグノズルジグノズルジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3『ジグステーション2』", "WorkItems": [ "7. を押しながら⑦を押す", "8. ⑧を押す", "9. ⑨を押す", "10. ノズルをチェンジャーから取り外したら⑩を押す", "11. ジグステーションを取り外してから⑪を押す", "8. R側も1~11の手順で実施する" ], "WorkPoints": [ "規格値 スキャン位置:(標準) ±5㎜ (ノズル) ±0.1㎜ チェンジャ高さ:±0.5㎜ 角度毎/角度毎認識毎オフセット:±0.1㎜ 装着/認識/計測回転中心:±0.2㎜ マルチ認識カメラオフセット:-60~-20 マルチ認識カメラゲイン:0~4 ヘッドカメラオフセット:-15~15 ヘッドカメラゲイン:0~3", "R側を続けて実施する場合は取り外し不要" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "検査表①:キャリブレーション", "検査表①:キャリブレーション", "WDQB-F013-104" ] }
{ "QualityItem": "規格確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "チェンジャ高さ:±0.5㎜", "Method": "目視(画面表示)", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ラインカメラ治具(多機能ヘッド)", "Size": "", "ToolOther": "N610004070AB", "WorkName": "キャリブレーション:STEP3『分割認識1』(3ノズルヘッドのみ)", "WorkItems": [ "1. ①を押し、 を押しながら②を押す", "2. 画面指示従って治具を取付け、 を押しながら③を押す", "3. ④を押す", "5. 画面指示従って治具を取付け、 を押しながら⑥を押す", "4. を押しながら⑤を押す" ], "WorkPoints": [ "分割数は「2分割」が選択されていること" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "画面指示通りに取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ラインカメラ治具(多機能ヘッド)", "Size": "", "ToolOther": "N610004070AB", "WorkName": "キャリブレーション:STEP3『分割認識2』(3ノズルヘッドのみ)", "WorkItems": [ "6. ⑦を押す", "7. を押しながら⑧を押す", "8. 画面指示従って治具を取付け、 を押しながら⑨を押す", "9. ⑩を押す", "10. ⑪を押す", "11. 治具を取り外してから、⑫を押す" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "画面指示通りに取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ラインカメラ治具(多機能ヘッド)", "Size": "", "ToolOther": "N610004070AB", "WorkName": "キャリブレーション:STEP3『分割認識3』(3ノズルヘッドのみ)", "WorkItems": [ "12. R側も1~11の手順で実施する" ], "WorkPoints": [ "規格値 位置(プラス、マイナス) 方向(正スキャン、逆スキャン) X/Y:±0.5㎜ 速度(低速、中速)" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "規格確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "・位置(プラス、マイナス)・方向(正スキャン、逆スキャン)・速度(低速、中速)X/Y:±0.5㎜", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ラインカメラ治具(多機能ヘッド)", "Size": "", "ToolOther": "N610004070AB", "WorkName": "キャリブレーション:STEP3『分割認識3』(3ノズルヘッドのみ)", "WorkItems": [ "12. R側も1~11の手順で実施する" ], "WorkPoints": [ "規格値 位置(プラス、マイナス) 方向(正スキャン、逆スキャン) X/Y:±0.5㎜ 速度(低速、中速)" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "検査表①:キャリブレーション", "WDQB-F013-104" ] }
{ "QualityItem": "規格確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "・位置(プラス、マイナス)・方向(正スキャン、逆スキャン)・速度(低速、中速)X/Y:±0.5㎜", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3「3分割認識」①※選択OP", "WorkItems": [ "1. 大型重量部品対応のライセンスの確認", "2. 設備オプション設定を実施" ], "WorkPoints": [ "装着速度退避動作をON" ], "Tolks": [], "InspectionNo": "WDQB-F013-103", "InspectionItems": [ "検査表①:オプションライセンス登録確認" ], "WorkTypes": [], "Words": [ "検査表①:設備オプション設定", "WDQB-F013-103" ] }
{ "QualityItem": "ライセンス確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りに登録出来ている事", "Method": "目視", "RecordMethod": "WDQB-F013-103", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP3「3分割認識」①※選択OP", "WorkItems": [ "1. 大型重量部品対応のライセンスの確認", "2. 設備オプション設定を実施" ], "WorkPoints": [ "装着速度退避動作をON" ], "Tolks": [], "InspectionNo": "WDQB-F013-103", "InspectionItems": [ "検査表①:設備オプション設定" ], "WorkTypes": [], "Words": [ "検査表①:オプションライセンス登録確認", "WDQB-F013-103" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りに設定出来ている事", "Method": "目視", "RecordMethod": "WDQB-F013-103", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ビルドアップキャリブレーション治具", "Size": "", "ToolOther": "N610168316AA", "WorkName": "キャリブレーション:STEP3「3分割認識」②※選択OP", "WorkItems": [ "1. 分割数を3分割にして計測スタートを押す", "2. 正常終了を確認後ホームボタンを押す", "3. ティーチ終了後、データを保存し、治具を取り外す", "4. パラメータの確認" ], "WorkPoints": [ "前後に3Nヘッドがある場合は、それぞれ実施する", "「位置」、「方向」を押下して、下記の組合せPos2へ入力されている事を確認" ], "Tolks": [], "InspectionNo": "WDQB-F013-103", "InspectionItems": [ "検査表①:キャリブレーション ステップ3" ], "WorkTypes": [], "Words": [ "ジグを「Pos2」に取付け、「実行」ボタンを押下します。", "ビルドアップキャリブレーション治具", "WDQB-F013-103" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りに設定出来ている事", "Method": "目視", "RecordMethod": "WDQB-F013-103", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "吸着位置高さティーチ治具", "Size": "", "ToolOther": "FM-3254", "WorkName": "キャリブレーション:STEP4『吸着位置1』", "WorkItems": [ "4. 2番スロットに吸着位置高さセンサ治具をセットする" ], "WorkPoints": [ "※台車を設備に接続し、実施すること" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "設置確認", "ToolManageNo": "FM-3254", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示ヵ所にセットされている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズルジグノズルジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP4『吸着位置1』", "WorkItems": [ "1. を押しながら①を押す", "2. 画面指示従ってノズルを取付け、 を押しながら②を押す", "3. を押しながら③を押す", "4. 2番スロットに吸着位置高さセンサ治具をセットする", "5. を押しながら④を押す" ], "WorkPoints": [ "※台車を設備に接続し、実施すること" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "画面指示通りに取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "高さティーチ治具ジグノズル", "Size": "", "ToolOther": "FM-32541002N", "WorkName": "キャリブレーション:STEP4『吸着位置2』", "WorkItems": [ "6. 15番スロットに吸着位置高さセンサ治具をセットする", "7. を押しながら⑤を押す", "8. 29番スロットに吸着位置高さセンサ治具をセットする", "9. を押しながら⑥を押す", "10. ⑦を押す", "11. ⑧を押す" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "表示確認", "ToolManageNo": "FM-32541002N", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "画面指示通りに取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP4『吸着位置3』", "WorkItems": [ "12. ノズルを取り外した後、⑨を押す", "13. R側も1~12の手順で実施する" ], "WorkPoints": [ "規格値 X/Y:±1.5㎜" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "吸着位置", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "規格値:X/Y:±1.5㎜", "Method": "目視(画面表示)", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "吸着位置高さティーチ治具", "Size": "", "ToolOther": "FM-3254", "WorkName": "キャリブレーション:STEP4『吸着位置1』(シングルトレイ仕様時)", "WorkItems": [ "2. 画面指示従ってノルを取付け、 を押しながら②を押す", "4. 19番スロットに吸着位置高さセンサ治具をセットする" ], "WorkPoints": [ "※キャリブレーションの対象は13連供給部にて実施" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "設置確認", "ToolManageNo": "FM-3254", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示ヵ所にセットされている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP4『吸着位置1』(シングルトレイ仕様時)", "WorkItems": [ "1. を押しながら①を押す", "2. 画面指示従ってノルを取付け、 を押しながら②を押す", "3. を押しながら③を押す", "4. 19番スロットに吸着位置高さセンサ治具をセットする", "5. を押しながら④を押す" ], "WorkPoints": [ "※キャリブレーションの対象は13連供給部にて実施" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "画面指示通りに取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "吸着位置高さティーチ治具", "Size": "", "ToolOther": "FM-3254", "WorkName": "キャリブレーション:STEP4『吸着位置2』(シングルトレイ仕様時)", "WorkItems": [ "6. 24番スロットに吸着位置高さセンサ治具をセットする", "7. を押しながら⑤を押す", "8. 29番スロットに吸着位置高さセンサ治具をセットする", "9. を押しながら⑥を押す", "6. 24番スロットに吸着位置高さセンサ治具をセットする", "7. を押しながら⑤を押す", "8. 29番スロットに吸着位置高さセンサ治具をセットする", "9. を押しながら⑥を押す" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "設置確認", "ToolManageNo": "FM-3254", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示ヵ所にセットされている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP4『吸着位置3』(シングルトレイ仕様時)", "WorkItems": [ "12. ノズルを取り外した後、⑨を押す" ], "WorkPoints": [ "規格値 X/Y:±1.5㎜" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "吸着位置", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "規格値:X/Y:±1.5㎜", "Method": "目視(画面表示)", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP4『トレイ1』", "WorkItems": [ "1. を押しながら①を押す", "2. 画面指示従って ノル ノズルを配置し、 を押しながら②を押す", "3. を押しながら③を押す", "4. 『認識エラー』が表示されたら④を押す", "5. ⑤を押す" ], "WorkPoints": [ "エラー表示がない場合は、手順9から実施" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "画面指示通りに出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP4『トレイ2』", "WorkItems": [ "6. ⑥を押て移動距離を替える", "7. インチングをして、マークをセンターにする", "8. を押しながら⑦を押す", "9. を押しながら⑧を押す", "10. 『認識エラー』が表示されたら⑨を押す" ], "WorkPoints": [ "エラー表示がない場合は、手順15から実施", "ダイレクト → 1 → 0.1 → 0.01の順番に切り替わる" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "ここを押すとマークが上に移動", "ここを押すとマークが下に移動", "ここを押すとマークが右に移動", "ここを押すとマークが左に移動" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "画面指示通りに出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP4『トレイ3』", "WorkItems": [ "14. を押しながら⑫を押す", "11. ⑩を押す", "12. ⑪を押して移動距離を替える", "13. インチングをして、マークをセンターにする", "15. ⑬を押す", "16. ⑭を押す" ], "WorkPoints": [ "ダイレクト → 1 → 0.1 → 0.01の順番に切り替わる" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "ここを押すとマークが上に移動", "ここを押すとマークが下に移動", "ここを押すとマークが右に移動", "ここを押すとマークが左に移動" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "画面指示通りに出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP4『トレイ4』", "WorkItems": [ "19. ツイントレイ仕様時は、トレイAを選択し手順1~17を実施する", "17. を押しながら⑮を押す", "18. チェンジャーからノズルを取り外す", "20. トレイBを選択し手順1~17を実施する" ], "WorkPoints": [ "規格値 吸着高さ:±2.0㎜ 吸着位置A:X=±7.0㎜ Y=±5.0㎜ 吸着位置B:X=±7.0㎜ Y=±5.0㎜", "規格値 吸着高さ:±2.0㎜ 吸着位置A:X=±7.0㎜ Y=±5.0㎜" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション", "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "吸着高さ(吸着位置)", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "・規格値吸着高さ:±2.0㎜", "Method": "目視(画面表示)", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP4『トレイ4』", "WorkItems": [ "19. ツイントレイ仕様時は、トレイAを選択し手順1~17を実施する", "17. を押しながら⑮を押す", "18. チェンジャーからノズルを取り外す", "20. トレイBを選択し手順1~17を実施する" ], "WorkPoints": [ "規格値 吸着高さ:±2.0㎜ 吸着位置A:X=±7.0㎜ Y=±5.0㎜ 吸着位置B:X=±7.0㎜ Y=±5.0㎜", "規格値 吸着高さ:±2.0㎜ 吸着位置A:X=±7.0㎜ Y=±5.0㎜" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション", "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "吸着位置", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "吸着位置A:X=±7.0㎜Y=±5.0㎜", "Method": "目視(画面表示)", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP4『トレイ4』", "WorkItems": [ "19. ツイントレイ仕様時は、トレイAを選択し手順1~17を実施する", "17. を押しながら⑮を押す", "18. チェンジャーからノズルを取り外す", "20. トレイBを選択し手順1~17を実施する" ], "WorkPoints": [ "規格値 吸着高さ:±2.0㎜ 吸着位置A:X=±7.0㎜ Y=±5.0㎜ 吸着位置B:X=±7.0㎜ Y=±5.0㎜", "規格値 吸着高さ:±2.0㎜ 吸着位置A:X=±7.0㎜ Y=±5.0㎜" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "検査表①:キャリブレーション", "検査表①:キャリブレーション", "WDQB-F013-104" ] }
{ "QualityItem": "吸着位置", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "吸着位置B:X=±7.0㎜Y=±5.0㎜", "Method": "目視(画面表示)", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP4『トレイ4』", "WorkItems": [ "19. ツイントレイ仕様時は、トレイAを選択し手順1~17を実施する", "17. を押しながら⑮を押す", "18. チェンジャーからノズルを取り外す", "20. トレイBを選択し手順1~17を実施する" ], "WorkPoints": [ "規格値 吸着高さ:±2.0㎜ 吸着位置A:X=±7.0㎜ Y=±5.0㎜ 吸着位置B:X=±7.0㎜ Y=±5.0㎜", "規格値 吸着高さ:±2.0㎜ 吸着位置A:X=±7.0㎜ Y=±5.0㎜" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "検査表①:キャリブレーション", "検査表①:キャリブレーション" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "画面指示通りに出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP5『搭載荷重測定1』(3ノズルヘッドのみ)", "WorkItems": [ "2. 『装着荷重』を押す", "4. を押しながら『実行』を押す", "1. キャリブレーション STEP5の画面を開く", "3. を押しながら『ジグ取付け』を押す" ], "WorkPoints": [ "一括交換台車をセットしておく事", "押す前に基板プレートにピンが無いことを確認する事", "実施する側が青色になっていることを確認する(違う場合は、押して青色に変更する)" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "画面操作", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "作業指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ロードセル", "Size": "", "ToolOther": "N610084605AB", "WorkName": "キャリブレーション:STEP5『搭載荷重測定2』(3ノズルヘッドのみ)", "WorkItems": [ "5. ロードセルを設置し、付属のケーブルを接続後、引き回す" ], "WorkPoints": [ "基板クランプ端面に合わせる", "基板クランプ端面に合わせる", "基板の流れ方向で設置場所を変える事", "左→右流れ", "右→左流れ", "ロードセル設置位置", "右 → 左流れ", "左 → 右流れ" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "基板クランプ", "基板クランプ", "ロードセル", "ロードセル", "FRONT" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "作業指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "LOADCELLMETERVER3", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP5『搭載荷重測定2』(3ノズルヘッドのみ)", "WorkItems": [ "5. ロードセルを設置し、付属のケーブルを接続後、引き回す", "6. ロードセルメーターを設置し、ロードセルからの配線を接続する", "7. ロードセルメーターの電源コードを交換台車の電源供給部のいずれかに接続する" ], "WorkPoints": [ "基板クランプ端面に合わせる", "基板クランプ端面に合わせる", "配線が干渉しない様引き回しを行う", "配線が干渉しない様引き回しを行う", "基板の流れ方向で設置場所を変える事", "左→右流れ", "右→左流れ", "ロードセル設置位置", "右 → 左流れ", "左 → 右流れ" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "基板クランプ", "基板クランプ", "ロードセルからの配線の接続端子", "電源供給部", "電源コード", "交換台車", "ロードセル", "ロードセルメーター", "ロードセル", "FRONT", "ロードセルの接続端子" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "作業指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "1003ノズル", "Size": "", "ToolOther": "KXFX037UA00", "WorkName": "キャリブレーション:STEP5『搭載荷重測定3』(3ノズルヘッドのみ)", "WorkItems": [ "12. を押しながら『荷重計測(F1)』を押す", "9. 指示に従いチェンジャにノズルを配置する", "11. ヘッドNoが\"1\"であることを確認する", "8. を押しながら『実行』を押す", "10. を押しながら『実行』を押す" ], "WorkPoints": [ "チェンジャF11番に1003ノズルを配置する", "ロードセルメーターはMAX値では正確な測定ができない為、 現在値で測定する事", "計測スタートするので、ロードセルメータ表示部の計測値を確認する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "荷重計測", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "表示部の数値を記録する", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP5『搭載荷重測定4』(3ノズルヘッドのみ)", "WorkItems": [ "13. 計測が完了したことを確認し、操作パネルの数値部を押す", "14. ロードセルメーターで読み取った数値を入力する", "15. を押しながら『荷重計測(F2)』を押す", "16. 計測が完了したことを確認し、操作パネルの数値部を押す" ], "WorkPoints": [ "数値を入力後、『ENT』を押す", "ロードセルメーターはMAX値では正確な測定ができない為、 現在値で測定する事", "計測スタートするので、ロードセルメータ表示部の計測値を確認する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "荷重計測", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "表示部の数値を記録する", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP5『搭載荷重測定5』(3ノズルヘッドのみ)", "WorkItems": [ "22. を押しながら『確認』を押す", "18. を押しながら『最小荷重確認』を押す", "17. 治具にて読み取った数値を入力する", "19. 計測が完了したことを確認し、操作パネルの数値部を押す", "20. 治具にて読み取った数値を入力する", "21. 『確認』を押し、18~20の手順を実施する" ], "WorkPoints": [ "入力値が0.5 N以下の場合:手順21へ入力値が0.5 N以上の場合:手順22へ", "数値を入力後、『ENT』を押す", "ロードセルメーターはMAX値では正確な測定ができない為、現在値で測定する事", "計測スタートするので、ロードセルメータ表示部の計測値を確認する", "数値を入力後、『ENT』を押す" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "荷重計測", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "表示部の数値を記録する", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP5『搭載荷重測定6』(3ノズルヘッドのみ)", "WorkItems": [ "25. 『はい』を押す", "23. ヘッドNoを押し他のヘッドも同様に実施する", "24. 全て完了したら『R』を押す", "26. を押しながら『実行』を押す" ], "WorkPoints": [ "荷重係数規格値:A:4.5~5.5、B:1~10", "Rear側を実施している場合は、『F』を押す" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "WDQB-F013-104" ] }
{ "QualityItem": "規格確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "荷重係数:A:4.4~5.5B:1~10", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP5『搭載荷重測定7』(3ノズルヘッドのみ)", "WorkItems": [ "27 ノズルチェンジャからノズルを取り外す", "28.     を押しながら㉘を押す", "29 ロードセル、ロードセルメーターを取り外す", "30.     を押しながら㉚を押す" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "画面操作", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "作業指示通り出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "高さセンサ治具", "Size": "", "ToolOther": "FM-2990", "WorkName": "キャリブレーション:STEP5『高さセンサ1』(オプション)", "WorkItems": [ "2. 治具をコンベアにセットする", "4. 指示に従い、ノズルを置く", "5. を押しながら『実行』を押す", "7. 正常に終了したことを確認し、『R』を押す" ], "WorkPoints": [ "右 → 左流れ", "左 → 右流れ", "高さセンサ用ジグ基板端面をガイドのマーク位置に合わせる" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "16/12ノズル8ノズル 3ノズル", ":230CSN:230CN:1002N" ] }
{ "QualityItem": "設置確認", "ToolManageNo": "FM-2990", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通りの位置にセットされている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP5『高さセンサ1』(オプション)", "WorkItems": [ "1. 高さセンサの画面を開き、 を押しながら『ジグ取付け』を押す", "3. を押しながら『実行』を押す", "2. 治具をコンベアにセットする", "4. 指示に従い、ノズルを置く", "5. を押しながら『実行』を押す", "6. を押しながら『高さ計測』を押す", "7. 正常に終了したことを確認し、『R』を押す" ], "WorkPoints": [ "右 → 左流れ", "左 → 右流れ", "高さセンサ用ジグ基板端面をガイドのマーク位置に合わせる" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "マシンが自動で計測を始める", "16/12ノズル8ノズル 3ノズル", ":230CSN:230CN:1002N" ] }
{ "QualityItem": "高さ測定", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りに入力されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "高さセンサ治具", "Size": "", "ToolOther": "FM-2990", "WorkName": "キャリブレーション:STEP5『高さセンサ2』(オプション)", "WorkItems": [ "8. 『はい』を押す", "9. を押しながら『はい』を押す", "10. ノズルチェンジャからノズルを取り外す", "12. ジグ基板を取り外す", "11. を押しながら『実行』を押す", "13. を押しながら『実行』を押す", "14. Rearも同様の手順で実施する" ], "WorkPoints": [ "計測(ティーチ)の値がNGであれば、タッチパネルの画面を変える時に \"リミット値を超えていますので保存でいません\" と表示される", "NGの場合、計測(ティーチ)の条件を見直し、 再度計測(ティーチ)を行う", "規格値X/Y:±3.0㎜ 傾き1,2:1±0.2 切片1,2:±1.0㎜ Z:±1.5㎜" ], "Tolks": [], "InspectionNo": "WDQB-F013-103", "InspectionItems": [ "検査表①:オプション" ], "WorkTypes": [], "Words": [ "治具基板とりはずし", "WDQB-F013-103" ] }
{ "QualityItem": "高さセンサ", "ToolManageNo": "FM-2990", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "X[㎜]:±3.0Y[㎜]:±3.0傾き1,2:1±0.2切片1,2[㎜]:±1.0Z[㎜]:±1.5", "Method": "目視", "RecordMethod": "WDQB-F013-103", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズル", "Size": "", "ToolOther": "", "WorkName": "キャリブレーション:STEP5『高さセンサ2』(オプション)", "WorkItems": [ "8. 『はい』を押す", "9. を押しながら『はい』を押す", "10. ノズルチェンジャからノズルを取り外す", "12. ジグ基板を取り外す", "11. を押しながら『実行』を押す", "13. を押しながら『実行』を押す", "14. Rearも同様の手順で実施する" ], "WorkPoints": [ "計測(ティーチ)の値がNGであれば、タッチパネルの画面を変える時に \"リミット値を超えていますので保存でいません\" と表示される", "NGの場合、計測(ティーチ)の条件を見直し、 再度計測(ティーチ)を行う", "規格値X/Y:±3.0㎜ 傾き1,2:1±0.2 切片1,2:±1.0㎜ Z:±1.5㎜" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "検査表①:オプション", "治具基板とりはずし", "WDQB-F013-103" ] }
{ "QualityItem": "高さセンサ", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "X[㎜]:±3.0Y[㎜]:±3.0傾き1,2:1±0.2切片1,2[㎜]:±1.0Z[㎜]:±1.5", "Method": "目視", "RecordMethod": "WDQB-F013-103", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズルジグノズルジグノズルジグノズル", "Size": "", "ToolOther": "", "WorkName": "ノズル交換動作テスト1", "WorkItems": [ "3. ステージ選択後、 を押しながら④を押す", "1. ①を押す", "2. ②を押す", "4. ノズルをチェンジャーにセットする", "5. ノズルセット後、 を押しながら⑤を押す" ], "WorkPoints": [ "ヘッド仕様に合ったノズルをセットする" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "本画面以降は12ノズルヘッドの画像ですが16,8,3ノズルの操作内容も同じ", "41,4231,3221,2211,12にセットする", "8ノズルヘッド仕様時のセット位置", "本画面以降はフロント側の画像ですがリア側も操作内容は同じです", "41,42,43,4431,32,33,3421,22,23,2411,12,13,14にセットする", "16ノズルヘッド仕様時セット位置", "41,42,4331,32,3321,22,2311,12,13にセットする", "12ノズルヘッド仕様時セット位置", "11,12,13にセットする", "3ノズルヘッド仕様時のセット位置" ] }
{ "QualityItem": "設置確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示ヵ所にセットされている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ノズル交換動作テスト2", "WorkItems": [ "6. を押しながら⑥を押す", "7. 回数が4以上になったらSTOPボタンを押す", "8. 動作停止後、回数が5以上になっているか確認する", "9. ⑦を押し画像をSDカードに保存する", "10. を押しながら⑧を押す", "11. ノズル取り出し後、 を押しながら⑨を押す", "7. R側も1~11の手順で実施する" ], "WorkPoints": [ "回数表示", "テスト動作開始", "回数表示", "エラー無きこと", "チェンジャーからノズルを取り出す", "エラー無きこと" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション", "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "STOPボタン", "WDQB-F013-104" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "エラー無き事(交換テスト/5サイクル以上実施)", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "本体設定確認①(装着荷重)", "WorkItems": [ "1. 装着ヘッド 調整/キャリブ完了確認", "2. 装着荷重計測ユニットの取付け設定", "3. 装着荷重計測ユニットの有効設定" ], "WorkPoints": [ "装着ヘッドの調整/キャリブが完了していること", "サービスマンモードにて下記設定を行ない、設定後設備再起動のこと", "サービスマンモードにて下記設定を行なうこと", "⑤⑥の設定は仕様を確認のこと" ], "Tolks": [], "InspectionNo": "WDQB-F013-103", "InspectionItems": [ "検査表①:装着ヘッド 調整/キャリブ確認" ], "WorkTypes": [], "Words": [ "検査表①:装着荷重計測ユニットの取付け設定", "①ホーム②サービスマン③動作パラメータ④オプション⑤No.63 荷重チェッカー(F)⇒前側搭載時、『ON』に設定変更のこと。⑥No.64 荷重チェッカー(R) ⇒後側搭載時、『ON』に設定変更のこと。", "検査表①:装着荷重計測ユニットの有効設定", "①マシン②設定③荷重チェッカー④オプション⑤一時中止⑥No.1 装着荷重計測 ⇒『ON』に設定変更のこと。", "WDQB-F013-103" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "画面指示通りに出来ている事", "Method": "目視", "RecordMethod": "WDQB-F013-103", "Other": "装着荷重チェッカー", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ジグノズルジグノズル", "Size": "", "ToolOther": "", "WorkName": "本体設定確認②(装着荷重)", "WorkItems": [ "1. 装着荷重計測ユニットのキャリブレーション" ], "WorkPoints": [ "エンジニアモードまたはサービスマンモードにて下記手順にて実施すること" ], "Tolks": [], "InspectionNo": "WDQB-F013-103", "InspectionItems": [ "検査表①:装着荷重計測ユニットのキャリブレーション" ], "WorkTypes": [], "Words": [ "①ホーム②キャリブレーション③第4工程④荷重チェッカー⑤荷重チェッカー位置測定", "各ヘッド毎の使用ノズルLW16NH :230CS12NH :230CSLW8NH :230C", "WDQB-F013-103" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "画面指示通りに出来ている事", "Method": "目視", "RecordMethod": "WDQB-F013-103", "Other": "装着荷重チェッカー", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "装着荷重計測(装着荷重)", "WorkItems": [ "1. 装着荷重計測ユニット 調整/キャリブ完了確認", "2. 装着荷重計測ユニットの動作確認", "3. ヘッド載せ変え確認" ], "WorkPoints": [ "装着荷重計測ユニットの調整/キャリブが完了していること", "エンジニアモードまたはサービスマンモードにて下記手順にて実施すること(後側も同様に行うこと)", "規格値:±40%以下", "※仕様を確認し装着荷重計測ユニットが搭載されている場合のみ実施のこと。", "検査ヘッドまたは塗布ヘッド搭載機の場合、仮搭載した軽量16ノズルヘッドを出荷のヘッド構成に変更すること。※検査ヘッドまたは塗布ヘッド搭載機のみ実施。", "仕様確認の事" ], "Tolks": [], "InspectionNo": "WDQB-F013-103", "InspectionItems": [ "検査表①:装着荷重計測ユニット 調整/キャリブ確認" ], "WorkTypes": [], "Words": [ "検査表①:装着荷重計測ユニットの動作確認", "①TBL1 or TBL2 ②メンテナンス③メンテナンス動作④ヘッド⑤装着荷重計測⑥計測スタート計測結果を検査表へ記入※ノズル本数分記載", "各ヘッド毎の使用ノズルLW16NH :230CS12NH :230CSLW8NH :230C", "検査表①:装着ヘッド載せ変え", "WDQB-F013-103" ] }
{ "QualityItem": "設定確認荷重測定", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "±40%以下", "Method": "目視", "RecordMethod": "WDQB-F013-103", "Other": "装着荷重チェッカー", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "装着荷重計測(装着荷重)", "WorkItems": [ "1. 装着荷重計測ユニット 調整/キャリブ完了確認", "2. 装着荷重計測ユニットの動作確認", "3. ヘッド載せ変え確認" ], "WorkPoints": [ "装着荷重計測ユニットの調整/キャリブが完了していること", "エンジニアモードまたはサービスマンモードにて下記手順にて実施すること(後側も同様に行うこと)", "規格値:±40%以下", "※仕様を確認し装着荷重計測ユニットが搭載されている場合のみ実施のこと。", "検査ヘッドまたは塗布ヘッド搭載機の場合、仮搭載した軽量16ノズルヘッドを出荷のヘッド構成に変更すること。※検査ヘッドまたは塗布ヘッド搭載機のみ実施。", "仕様確認の事" ], "Tolks": [], "InspectionNo": "WDQB-F013-103", "InspectionItems": [ "検査表①:装着荷重計測ユニットの動作確認" ], "WorkTypes": [], "Words": [ "検査表①:装着荷重計測ユニット 調整/キャリブ確認", "①TBL1 or TBL2 ②メンテナンス③メンテナンス動作④ヘッド⑤装着荷重計測⑥計測スタート計測結果を検査表へ記入※ノズル本数分記載", "各ヘッド毎の使用ノズルLW16NH :230CS12NH :230CSLW8NH :230C", "検査表①:装着ヘッド載せ変え", "WDQB-F013-103" ] }
{ "QualityItem": "作業確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "作業指示通り完了している事", "Method": "目視", "RecordMethod": "WDQB-F013-103", "Other": "検査ヘッド、塗布ヘッド仕様", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "ラインSW-BoxSDカード", "Size": "", "ToolOther": "FM-2460―", "WorkName": "基板搬送確認1", "WorkItems": [ "1. ラインSW BOXを接続する", "2. ①を押す", "3. ②を押す", "4. ③を押す", "4. SDカードをマシンに挿入する" ], "WorkPoints": [ "仕様により接続位置が違うので注意する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "[本体] [SWBOX] XL - XS", "■右→左流れ時", "[本体] [SWBOX] XR - XS", "■左→右流れ時" ] }
{ "QualityItem": "接続確認", "ToolManageNo": "FM-2460―", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "仕様にあった接続が出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "基板搬送確認2", "WorkItems": [ "5. ④を押す", "6. ⑤を押し、搬送データを検索する", "9. ⑧を押した後、レーン2も6~8の手順を実施する", "10. ⑨を押す", "7. 基板サイズに合ったデータを選択し、⑥を押す", "8. ⑦を押す" ], "WorkPoints": [ "シングルコンベア仕様時 HANSOU-SINGLE-550 (750×550) HANSOU-MIN (50×50)デュアルコンベア仕様時 HANSOU-DUAL-S-510 (750×550) HANSOU-DUAL-D-260 (750×260) HANSOU-MIN (50×50)", "シングルコンベア仕様時は、手順10へデュアルコンベア仕様時は、手順9へ" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "仕様にあった手順が出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "基板搬送確認3", "WorkItems": [ "11. ⑩を押し『ON』にした後、⑪を押す", "12. 『10』と入力しENTを押す", "15. ⑭を押した後、レーン2も11~14の手順を実施する", "16. ⑮を押す", "13. ⑫を押す", "14. ⑬を押す" ], "WorkPoints": [ "シングルコンベア仕様時は、手順16へデュアルコンベア仕様時は、手順15へ" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "仕様にあった手順が出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "基板搬送確認4", "WorkItems": [ "21. を押しながらSTART SWを押す", "17. ⑯を押す", "18. ⑰を押す", "20. ⑲を押す", "19. ⑱を押した後、レーン2も17~18の手順を実施する" ], "WorkPoints": [ "シングルコンベア仕様時は、手順20へデュアルコンベア仕様時は、手順19へ", "生産が開始される" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "仕様にあった手順が出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "搬送確認基板", "Size": "", "ToolOther": "FM-2142FM-2998FM-3072FM-3073", "WorkName": "基板搬送確認5", "WorkItems": [ "22. 搬入待ちになったら基板を搬入する" ], "WorkPoints": [ "搬入方法(シングルモードの場合)", "搬入方法(デュアルモードの場合)" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "工程待ちになったら基板を搬入する", "レーン1側の基板が実装ステージに到着する", "レーン2側の基板が実装ステージに到着する", "押すと搬送状況が見える画面になる", "基板が実装ステージに到着する", "工程待ちになったらレーン1側に基板を搬入する", "レーン2側も同様に基板を搬入する" ] }
{ "QualityItem": "搬送確認", "ToolManageNo": "FM-2142FM-2998FM-3072FM-3073", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "仕様にあった手順で、あること", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "基板搬送確認6", "WorkItems": [ "23. 搬出待ちになったら基板を搬出する" ], "WorkPoints": [ "搬出方法(シングルモードの場合)", "搬出方法(デュアルモードの場合)" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "搬出待ちになったらMR.RDYをONする", "搬出待ちになったらMR.RDYをONする", "基板が完全に搬出されたらMR.RDYをOFFする", "排出後、搬入程待ちになるので、10枚流すまで、搬入、搬出を繰り返す", "レーン1が搬出待ちになったらMR.RDYをONする", "レーン2が搬出待ちになったらSR.RDYをONする", "搬出後、搬入待ちになるので、10枚流すまで、搬入、搬出を繰り返す(レーン1・2共に)", "レーン1の基板が完全に搬出されたらMR.RDYをOFFする", "レーン2の基板が完全に搬出されたらSR.RDYをOFFする" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "基板搬入・搬出が正常な事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "基板搬送確認7", "WorkItems": [ "24. 10枚搬送完了後、SDカードに保存しフォーマットファイルに貼付けプリントアウトする", "25. 各基板を、1~25の手順で実施する" ], "WorkPoints": [ "デュアルモードの場合", "基板データ保存", "レーン1稼動情報保存", "レーン2稼動情報保存", "シングルモードの場合", "基板データ保存", "稼動情報保存", "基板が正常に搬送すること", "基板が正常に搬送すること" ], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:基板搬送動作", "検査表①:基板搬送動作" ], "WorkTypes": [], "Words": [ "押す", "押してSDに記録する基板データは、レーン1の画像の事", "押してSDに記録する", "押してSDに記録する", "押す", "押す", "押す", "押してSDに記録する", "押す", "押してSDに記録する", "プリンタアイコンが出てない場合はココ", "WDQB-F013-104" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "仕様にあった手順で、あること", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "アワーメータ設定確認", "WorkItems": [ "1. アワーメータを設定する" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "WDQB-F013-104", "InspectionItems": [ "検査表①:キャリブレーション" ], "WorkTypes": [], "Words": [ "サービスマンモードで変更", "押す", "押す", "押す", "押す", "押す", "アワーメータが表示されているか確認する", "押す", "削除マシンソフト(V10.02.04以降対応)", "WDQB-F013-104" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "アワメータ設定OFF→ONON→OFF", "Method": "目視", "RecordMethod": "WDQB-F013-104", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "2㎜", "ToolOther": "81cN・m", "WorkName": "チャートマークブロック取付", "WorkItems": [ "1. 軽量16ノズルヘッドV3Aに①をBOLT で取付" ], "WorkPoints": [ "面取りが右側", "前後に軽量16ノズルヘッドV3Aがある場合はそれぞれ取付のこと" ], "Tolks": [ "締付トルク 81cN・m" ], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "81cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "SDカード", "Size": "", "ToolOther": "", "WorkName": "エージング動作1", "WorkItems": [ "1. ①『段取り』を押す", "2. ②『ファイル操作』を押す", "3. ③マシンデータが入ったSDカードをセットする", "4. ④『確認』を押す", "5. ⑤『SD』を押し、読み込み元をSDに切り替える", "8. ⑧『はい』を押す", "9. ⑨データが読み込まれたか、確認する", "10. ⑩『TBL2』を押し、レーン2も6~9を行う", "7. ⑦『SD⇒マシン』を押し、データのロードを行う", "2. ②『稼働情報』を押す", "3. ③『クリア』を押す", "4. ④『はい』を押す", "5. 生産情報等の各項目が『0』になっている事を 確認する", "1. ①『生産管理』を押す" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "-生産準備(生産管理情報クリア)-", "1. ①『マシン』 を押す", "2. ②『設定』 を押す", "3. ③『マルチ認識カメラ』 を押す", "4. ④『動作パラメータ』 を押す", "5. ⑤『判定』 を押す", "6. ⑥『認識OK率』 の設定値を押す", "7. ⑦ 「9」 と入力し 『ENT』 を押す", "-設定変更(認識OK率変更)-" ] }
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "仕様にあった手順が出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "エージング動作2", "WorkItems": [ "1. ①『生産』を押す", "2. ②『調整用ソフトスイッチ』を押す", "3. ③『装着・幅調整・吸着・基板認識・部品認識』をON、 それ以外を全てOFFにする", "1. ①『生産』を押す", "2. 操作パネルの を押しながら を押し 生産を開始する", "3. ③認識率の警告が表示されるので 『はい』を押す" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "-段取り替え(データロード)-", "-エージング開始-" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "正常な事エラー停止無き事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "エージング動作3", "WorkItems": [ "1. 規定時間のエージング動作を行う" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "調整用ソフトスイッチの設定を行う", "①押す", "② をおしながら『はい』を押す", "STOP SWを押しエージング動作を停止させる", "-設定変更(認識OK率リセット)-", "3. ⑧確認画面が出るので 『はい』 を押す", "1. ①『マシン』 →②『設定』 →③『マルチ認識カメラ』 →④『動作パラメータ』 →⑤『判定』 →⑥『認識OK率』 の項目No の順番にボタンを押す", "2. ⑦『リセット』 を押す" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "正常な事エラー停止無き事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "スケール", "Size": "150㎜", "ToolOther": "", "WorkName": "フィーダテーブルカバー組立1", "WorkItems": [ "2. COVER にTAPE を貼付", "1. TAPE を指定の長さにカットする", "2. COVER にTAPE を貼付", "1. TAPE を指定の長さにカットする" ], "WorkPoints": [ "46㎜", "COVER 脱脂後TAPE を貼付ける", "46㎜", "COVER 脱脂後TAPE を貼付ける" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "50㎜", "この作業では同じものを4個製作", "50㎜", "この作業では同じものを4個製作" ] }
{ "QualityItem": "寸法確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示寸法各±0.5㎜", "Method": "スケール", "RecordMethod": "-", "Other": "-", "ProcessNames": [] }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "安全SW組立", "WorkItems": [ "■1. SWITCH の型式確認しロットNo.を記録", "3. ①に2完成品をBOLT WASHER で取付", "2. BRACKET にSWITCH をBOLT で取付" ], "WorkPoints": [ "ロットNo.", "型式", "ロットNo.", "型式", "フィーダカバー用", "開閉カバー用", "▲印の方向に注意", "矢印方向に当てつけ", "この工程ではフィーダカバー用SWのみ使用開閉カバー用SWは開閉カバー組立で使用", "F側とR側に区別をしておくこと", "貼付け位置", "検査書記載後㉘マスキングテープに型式とロットNoを記載し①に貼付け", "開閉カバー F側とR側のロット№を合わせること", "矢印方向に当てつけ", "2SET製作" ], "Tolks": [ "締付トルク 100cN・m", "締付トルク 194cN・m" ], "InspectionNo": "WETE-G002-C14", "InspectionItems": [ "検査表①:2.安全SWの型式とロットNoを記録" ], "WorkTypes": [], "Words": [ "取付け方向に注意!この部品には方向性があります", "WETE-G002-C14" ] }
{ "QualityItem": "型式確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "型式が一致する事ロット№転記", "Method": "目視", "RecordMethod": "WETE-G002-C14", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "3㎜", "ToolOther": "100cN・m", "WorkName": "安全SW組立", "WorkItems": [ "■1. SWITCH の型式確認しロットNo.を記録", "3. ①に2完成品をBOLT WASHER で取付", "2. BRACKET にSWITCH をBOLT で取付" ], "WorkPoints": [ "ロットNo.", "型式", "ロットNo.", "型式", "フィーダカバー用", "矢印方向に当てつけ", "この工程ではフィーダカバー用SWのみ使用開閉カバー用SWは開閉カバー組立で使用" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "取付け方向に注意!この部品には方向性があります", "■安全作業" ] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "100cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "T20", "ToolOther": "194cN・m", "WorkName": "安全SW組立", "WorkItems": [ "■1. SWITCH の型式確認しロットNo.を記録", "3. ①に2完成品をBOLT WASHER で取付", "2. BRACKET にSWITCH をBOLT で取付" ], "WorkPoints": [ "ロットNo.", "型式", "ロットNo.", "型式", "フィーダカバー用", "矢印方向に当てつけ", "この工程ではフィーダカバー用SWのみ使用開閉カバー用SWは開閉カバー組立で使用" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "WorkTypes": [], "Words": [ "取付け方向に注意!この部品には方向性があります", "■安全作業" ] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "194cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessNames": [ "安全工程" ] }
information_extraction
0
null