input stringclasses 1 value | instruction stringlengths 228 3.39k | output stringlengths 287 3.32k | category stringclasses 1 value | index stringclasses 1 value | fileName null |
|---|---|---|---|---|---|
{
"UnitName": "本体組込検査表_(H2H3工程)(001-134)",
"WorkName": "カバー安全SW動作確認",
"Words": [
"AM",
"P1",
"P2",
"AM",
"TCP"
],
"WorkItems": [
"■1. 各カバー(扉)を開けて全軸原点復帰動作をさせ安全SWの動作を確認する"
],
"WorkPoints": [
"カバー(扉)を開け状態では安全SWが働きマシンが動作しないこと",
"A_前面LR扉2枚(安全SW_2箇所)",
"M_前面LR扉2枚(安全SW_2箇所)",
"P1_前面LR扉2枚(安全SW_2箇所)",
"P2_前面LR扉2枚(安全SW_2箇所)",
"M_背面 供給部切替用扉2枚(安全SW_1箇所)",
"M_背面 IC供給後上下扉2枚(安全SW_2箇所)",
"TCP供給部:扉3枚(安全SW_3箇所)"
],
"Tolks": [],
"InspectionItems": [
"検査表①:カバー安全SW動作確認"
],
"InspectionNos": [
"WWYJ-5500-006"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "カバー安全SW動作確認",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "カバーを開け状態ではマシンが動作しないこと",
"Method": "目視",
"RecordMethod": "WWYJ-5500-006",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体組込検査表_(H2H3工程)(001-134)",
"WorkName": "PLラベル貼付検査",
"Words": [],
"WorkItems": [
"■1. PL警告ラベル貼付検査表に基き検査を行う"
],
"WorkPoints": [
"文書番号:WWYJ-4900-001を参照(下記参考)"
],
"Tolks": [],
"InspectionItems": [
"検査表①:PLラベル貼付検査"
],
"InspectionNos": [
"WWYJ-5500-006"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "PLラベル貼付検査",
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示位置に貼付けている事",
"Method": "スケール",
"RecordMethod": "WWYJ-5500-006",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体組込検査表_(H2H3工程)(001-134)",
"WorkName": "絶縁・耐圧・PE結合試験",
"Words": [],
"WorkItems": [
"■1. 安全工程試験検査表に基き検査を行う"
],
"WorkPoints": [
"※直送の場合は工程検査で実施するため省略可",
"文書番号:WWYJ-5500-003を参照"
],
"Tolks": [],
"InspectionItems": [
"検査表①:絶縁・耐圧・PE結合試験"
],
"InspectionNos": [
"WWYJ-5500-006"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "絶縁・耐圧・PE結合試験",
"QualityItem": "安全確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-006",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "本体レベル高さ出しAM(連結)",
"Words": [
"架台高さ 605mm",
"参考:パネル受渡高さ"
],
"WorkItems": [
"1. 床面よりAM架台の高さを調整する。",
"2. 架台のレベルを調整する"
],
"WorkPoints": [
"規格:605mm±5mm以内",
"規格:0.06mm以内"
],
"Tolks": [],
"InspectionItems": [
"検査表①:本体レベル高さ出し"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "スケール",
"Size": "1000㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "コンベックス",
"Size": "3m",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "スパナ",
"Size": "46㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.29",
"ToolName": "水準器",
"Size": "0.02㎜/目盛",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.28,29",
"使用治工具No.26,27"
]
} | [
{
"WorkName": "本体レベル高さ出しAM(連結)",
"QualityItem": "寸法確認",
"ToolManageNo": "-",
"ToolName": "スケール",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "架台上面高さ605㎜±5㎜",
"Method": "スケール",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"-"
]
},
{
"WorkName": "本体レベル高さ出しAM(連結)",
"QualityItem": "寸法確認",
"ToolManageNo": "-",
"ToolName": "コンベックス",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示の寸法である事",
"Method": "コンベックス",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"-"
]
},
{
"WorkName": "本体レベル高さ出しAM(連結)",
"QualityItem": "水準確認",
"ToolManageNo": "-",
"ToolName": "水準器",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "XY=0.06㎜以下",
"Method": "水準器",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"-"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "本体レベル高さ出しP1(連結)",
"Words": [
"P1架台水準器設置個所",
"AM",
"P1",
"スライディングペーパー",
"AM",
"P1",
"AM",
"P1",
"P1",
"AM"
],
"WorkItems": [
"1. AM架台にP1架台を近づけ仮レベル調整を行う。(架台の高さはAMに合わせる)",
"2. アジャストボルトにスライディングペーパーを敷きP1架台をAM架台に寄せる。",
"3.P1架台のレベル調整を行いながら連結ブッロクでAMPの連結を行う。"
],
"WorkPoints": [
"連結ブロック間に隙間が無い事",
"架台水準_規格:0.06mm以内",
"架台の高さ※AM架台と合わせる"
],
"Tolks": [],
"InspectionItems": [
"検査表①:本体レベル高さ出し"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "スケール",
"Size": "1000㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "スケール",
"Size": "150㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "スパナ",
"Size": "46㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.29",
"ToolName": "水準器",
"Size": "0.02㎜/目盛",
"Other": "-"
},
{
"JiguNo": "使用治工具No.30",
"ToolName": "スライディングペーパー",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.29",
"使用治工具No.26,28,29",
"使用治工具No.27,28,29,30"
]
} | [
{
"WorkName": "本体レベル高さ出しP1(連結)",
"QualityItem": "寸法確認",
"ToolManageNo": "-",
"ToolName": "スケール",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "架台高さAM架台と合わせる",
"Method": "スケール",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"-"
]
},
{
"WorkName": "本体レベル高さ出しP1(連結)",
"QualityItem": "寸法確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "連結ブロックに隙間無い事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"-"
]
},
{
"WorkName": "本体レベル高さ出しP1(連結)",
"QualityItem": "水準確認",
"ToolManageNo": "-",
"ToolName": "水準器",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "XY=0.06㎜以下",
"Method": "水準器",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"-"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "本体レベル高さ出しP2(連結)",
"Words": [
"AM",
"P1",
"P2",
"AM",
"P1",
"P2",
"P2架台水準器設置個所",
"スライディングペーパー",
"AM",
"P1",
"P1",
"AM",
"P2"
],
"WorkItems": [
"1. AM架台にP1架台を近づけ仮レベル調整を行う。(架台の高さはAMに合わせる)",
"2. アジャストボルトにスライディングペーパーを敷きP2架台をP1架台に寄せる。",
"3.P2架台のレベル調整を行いながら連結ブッロクでP1との連結を行う。"
],
"WorkPoints": [
"連結ブロック間に隙間が無い事",
"架台水準_規格:0.06mm以内",
"架台の高さ※P1架台と合わせる"
],
"Tolks": [],
"InspectionItems": [
"検査表①:本体レベル高さ出し"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "スケール",
"Size": "1000㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "スケール",
"Size": "150㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "スパナ",
"Size": "46㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.29",
"ToolName": "水準器",
"Size": "0.02㎜/目盛",
"Other": "-"
},
{
"JiguNo": "使用治工具No.30",
"ToolName": "スライディングペーパー",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26,28,29",
"使用治工具No.30",
"使用治工具No.27,28,29,30"
]
} | [
{
"WorkName": "本体レベル高さ出しP2(連結)",
"QualityItem": "寸法確認",
"ToolManageNo": "-",
"ToolName": "スケール",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "架台高さP1架台と合わせる",
"Method": "スケール",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"-"
]
},
{
"WorkName": "本体レベル高さ出しP2(連結)",
"QualityItem": "寸法確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "連結ブロックに隙間無い事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"-"
]
},
{
"WorkName": "本体レベル高さ出しP2(連結)",
"QualityItem": "水準確認",
"ToolManageNo": "-",
"ToolName": "水準器",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "XY=0.06㎜以下",
"Method": "水準器",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"-"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "本体連結(配線、配管)①",
"Words": [
"AM前面",
"P1前面",
"①CPUーBOX",
"②AM connecter bracket",
"③P1 RING負荷(K3011)",
"P2",
"①",
"②",
"③",
"P1からの配管接続"
],
"WorkItems": [
"1. AM-P1間の配線、配管を接続する。(架台側面の抜き穴を通す)"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "本体連結(配線、配管)①",
"QualityItem": "接続確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り接続出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"-"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "本体連結(配線、配管)②",
"Words": [
"P2",
"①",
"②",
"③",
"P1背面",
"P1前面",
"①P1背面RING負荷K3003",
"② 連結コネクタブラケット",
"③ P1 RING負荷(K300A)",
"P2前面",
"P2からの配管接続",
"P1(背面)"
],
"WorkItems": [
"1. P1-P2間の配線、配管を接続する。(架台側面の抜き穴を通す)"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "本体連結(配線、配管)②",
"QualityItem": "接続確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り接続出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"-"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "電源接続確認",
"Words": [
"※締付トルク:電源線(赤・白・黒) 250cN・m アース線 180cN・m"
],
"WorkItems": [
"1. 設備後面電源カバーを外す",
"■2. 電源カバー上面の丸穴より電源ケーブルを入れ込み端子台の所定位置へ接続",
"3. 設備側にエアーホース/真空ホースを接続する",
"4. 真空ポンプの電源ON",
"5. 工場側にエアーホース/電源ケーブルを接続する",
"6. 設備のエアーコックON",
"7. 設備の電源ON"
],
"WorkPoints": [],
"Tolks": [
"締付トルク 250cN・m",
"締付トルク 180cN・m"
],
"InspectionItems": [
"検査表①:電源接続確認"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業",
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "+ドライバー",
"Size": "No.2",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "トルクドライバー",
"Size": "No.2",
"Other": "250cN・m"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "トルクドライバー",
"Size": "No.2",
"Other": "180cN・m"
}
],
"Jigus": [
"使用治工具No.26",
"使用治工具No.26,27,28"
]
} | [
{
"WorkName": "電源接続確認",
"QualityItem": "接続確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り接続出来ている事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
},
{
"WorkName": "電源接続確認",
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolName": "トルクドライバー",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "250cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
},
{
"WorkName": "電源接続確認",
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolName": "トルクドライバー",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "180cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "メインエアー/メイン真空圧設定",
"Words": [
"センサー表示を参照しながら調整",
"メイン真空レギュレータ真空1真空2",
"センサー表示を参照しながら調整",
"メインエアーレギュレータ"
],
"WorkItems": [
"1. カバーを外し、メインエアー圧の設定を行う(正圧)",
"2. メイン真空圧設定を行う(負圧)"
],
"WorkPoints": [
"設備メインエアーを投入し,レギュレータで設定になるよう調整する",
"規格:0.45MPa±0.03MPa",
"設備メイン真空を投入し、レギュレータで設定になるよう調整する(真空1/真空2)",
"規格:-80KPa以下"
],
"Tolks": [],
"InspectionItems": [
"検査表①:メインエアー/メイン真空圧設定",
"検査表①:メインエアー/メイン真空圧設定"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "+ドライバー",
"Size": "No.2",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26"
]
} | [
{
"WorkName": "メインエアー/メイン真空圧設定",
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "メインエア(正圧)0.45MPa±0.03",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
},
{
"WorkName": "メインエアー/メイン真空圧設定",
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "メイン真空(負圧)-80kPa以下",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "付属品確認",
"Words": [
"付属品リスト一覧(表紙) (本体)",
"●付属品明細(A)FPX005CG 標準部",
"●付属品明細(B)FPX005CG オプション部",
"●付属品明細(C)機種切替部品",
"●(D)FPX005CG 標準工具セット",
"●(F)制御オプション部"
],
"WorkItems": [
"1. 付属品リストを基に付属品の有無確認を実施する"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:付属品確認"
],
"InspectionNos": [],
"WorkTypes": [
"●クリーン作業",
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "付属品確認",
"QualityItem": "物品確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "リストの物がある事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "個別仕様/選択仕様確認",
"Words": [],
"WorkItems": [
"1. 仕様チェックリストを基に仕様確認を行う(集約仕様書を参照の上、仕様確認)"
],
"WorkPoints": [
"お客様個別に設備仕様が異なるので工事機番を間違えないよう集約仕様書を基に確認を行う事"
],
"Tolks": [],
"InspectionItems": [
"検査表①:個別仕様選択仕様確認"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "個別仕様/選択仕様確認",
"QualityItem": "仕様確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "リスト通りの仕様である事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "絶縁・耐圧・PE結合試験",
"Words": [],
"WorkItems": [
"■1. 絶縁・耐圧・PE結合試験を行う"
],
"WorkPoints": [
"安全工程試験検査表に基き検査を行う"
],
"Tolks": [],
"InspectionItems": [
"検査表①:絶縁・耐圧・PE結合試験"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "絶縁・耐圧・PE結合試験",
"QualityItem": "電気試験確認",
"ToolManageNo": "-",
"ToolName": "PE結合試験機",
"ToolCycle": "1回/年",
"ToolRecord": "PE結合試験機台帳",
"StdVal": "試験機判定",
"Method": "PE結合試験機",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
},
{
"WorkName": "絶縁・耐圧・PE結合試験",
"QualityItem": "電気試験確認",
"ToolManageNo": "-",
"ToolName": "絶縁耐圧試験機",
"ToolCycle": "1回/年",
"ToolRecord": "絶縁耐圧試験台帳",
"StdVal": "試験機判定",
"Method": "絶縁耐圧試験機",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "ACF貼付部圧力測定1",
"Words": [
"①ロードセルとアンプ接続②メジャーSWに設定③セットボタンを長押し、F-1を表示④再度、セットボタンを長押し、ゼロボタンを押し、 小数点が下3桁目にくるようにゼロボタンで設定 設定後、セットボタン長押し⑤ピークホールドボタンを押して F-3を表示させる⑥セットボタン長押し、ロードセルのひずみ値( mV/V) の数字をゼロボタン・ピークホールドボタンで入力後、セットボタン長押し⑦ロードセルの定格荷重(N)を入力後、セットボタン長押し⑧荷重の小数点の位置をゼロボタンで設定後、セットボタン長押し⑨ゼロボタンを長押し、LEDを点灯させたら完了",
"圧力治具",
"ロードセルアンプ",
"200Nロードセル",
"ヒータ温度は制御停止で測定する事",
"アンプ設定方法"
],
"WorkItems": [
"2. 【データ管理メニュー】-【マシンデータ編集】-【プロセスデータ荷重】-【プロセス確認荷重】-【A】-【ユーザー設定プロセス条件】-軸関係の退避を行う",
"1. ロードセルとアンプを接続しアンプの設定を行う(治具取付け)",
"3. ACFバックアップステージの取外し治具をセットする",
"4. 【荷重確認時間】:2s、【繰り返し回数】:3回、【ヘッドL荷重】:20、90、160Nの3条件を設定し、レギュレータを左下数値に設定"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:ACF貼付部圧力測定"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "ロードセル",
"Size": "-",
"Other": "200N"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "ロードセルアンプ",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "ACF圧力測定治具",
"Size": "-",
"Other": "FM-3269"
}
],
"Jigus": [
"使用治工具No.26,27,28"
]
} | [
{
"WorkName": "ACF貼付部圧力測定1",
"QualityItem": "動作確認",
"ToolManageNo": "FM-3269",
"ToolName": "ACF圧力測定治具",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "ACF圧力測定治具",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
},
{
"WorkName": "ACF貼付部圧力測定1",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "ロードセル",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "正常な事",
"Method": "ロードセル",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
},
{
"WorkName": "ACF貼付部圧力測定1",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "ロードセルアンプ",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "正常な事",
"Method": "ロードセルアンプ",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "ACF貼付部圧力測定2",
"Words": [
"※計算値を結果登録し、再度、③荷重計測をする"
],
"WorkItems": [
"5. 【計測開始】を押す",
"6. 前ページの測定ポイント計測後、【換算定数自動計算】を押し、表の値を入力し、【計算実行】を押す",
"8. R側ヘッドも同様に測定を行い事前データを完成させる",
"7. 結果登録後、再度20、90、160Nを測定し事前データへ記入する"
],
"WorkPoints": [
"規格:入力値が50N未満は±5N、50N以上は±10%"
],
"Tolks": [],
"InspectionItems": [
"検査表①:ACF貼付部圧力測定"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "ACF貼付部圧力測定2",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "入力値の±5Nもしくは±10%の大きい方",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "仮圧着部圧力測定1",
"Words": [
"①ロードセルとアンプ接続②メジャーSWに設定③セットボタンを長押し、F-1を表示④再度、セットボタンを長押し、ゼロボタンを押し、 小数点が下3桁目にくるようにゼロボタンで設定 設定後、セットボタン長押し⑤ピークホールドボタンを押して F-3を表示させる⑥セットボタン長押し、ロードセルのひずみ値( mV/V) の数字をゼロボタン・ピークホールドボタンで入力後、セットボタン長押し⑦ロードセルの定格荷重(N)を入力後、セットボタン長押し⑧荷重の小数点の位置をゼロボタンで設定後、セットボタン長押し⑨ゼロボタンを長押し、LEDを点灯させたら完了",
"5. 治具厚み計測を行う:【押込み量】:0.2mm、【荷重確認時間】:2s、【繰り返し回数】:3回、 【ヘッド荷重】:50N、レギュレータを左下数値に設定後、【治具厚み計測】を押す",
"ロードセルアンプ",
"200Nロードセル",
"ヒータ温度は制御停止で測定する事",
"2. 【データ管理メニュー】-【マシンデータ編集】-【プロセスデータ荷重】-【プロセス確認荷重】-【M】-【ユーザー設定プロセス条件】-軸関係の退避を行う",
"圧力治具",
"①-1 「部品データ」⇒「設備動作」⇒「仮圧ヘッド゙動作」 仮圧着速度:20mm/s①-2 「マシンデータ」⇒「〔M〕仮圧着」⇒「仮圧ヘッド」 仮圧着速度距離:0.5mm",
"アンプ設定方法"
],
"WorkItems": [
"1. ロードセルとアンプを接続しアンプの設定を行う(治具取付け)",
"4. パラメータ確認",
"3. 仮圧バックアップステージに治具をセットする"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:仮圧着部圧力測定"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "ロードセル",
"Size": "-",
"Other": "200N"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "ロードセルアンプ",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "仮圧圧力測定治具",
"Size": "-",
"Other": "FM-3567"
}
],
"Jigus": [
"使用治工具No.26,27,28"
]
} | [
{
"WorkName": "仮圧着部圧力測定1",
"QualityItem": "動作確認",
"ToolManageNo": "FM-3567",
"ToolName": "仮圧圧力測定治具",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "仮圧圧力測定治具",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
},
{
"WorkName": "仮圧着部圧力測定1",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "ロードセル",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "正常な事",
"Method": "ロードセル",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
},
{
"WorkName": "仮圧着部圧力測定1",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "ロードセルアンプ",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "正常な事",
"Method": "ロードセルアンプ",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "仮圧着部圧力測定2",
"Words": [
"①",
"②",
"③",
"⑤",
"⑥",
"⑦",
"④",
"6. ①【ヘッド原点位置移動】-②【隙間量移動】-③【はい】-④ロードセルをセット、⑤【微調整ボタンで】⑥【ヘッド下降上昇】で5N出力する高さをティーチ ⑦【結果登録】で治具厚み計測完了",
"7. 【ヘッド荷重】:10、30、50, 75 ,100Nの3条件を 設定し 【計測開始】",
"8. 前ページの測定ポイント計測後、【換算定数自動計算】を押し、 表の値を入力し、【計算実行】を押す"
],
"WorkItems": [
"9. 結果登録後、再度10、30、50、75、100Nを測定し事前データへ記入する"
],
"WorkPoints": [
"規格:入力値±10%"
],
"Tolks": [],
"InspectionItems": [
"検査表①:仮圧着部圧力測定"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "仮圧着部圧力測定2",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "入力値の±10%以下",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "本圧着部[P1][P2]圧力測定1",
"Words": [
"①ロードセルとアンプ接続②メジャーSWに設定③セットボタンを長押し、F-1を表示④再度、セットボタンを長押し、ゼロボタンを押し、 小数点が下3桁目にくるようにゼロボタンで設定 設定後、セットボタン長押し⑤ピークホールドボタンを押して F-3を表示させる⑥セットボタン長押し、ロードセルのひずみ値( mV/V) の数字をゼロボタン・ピークホールドボタンで入力後、セットボタン長押し⑦ロードセルの定格荷重(N)を入力後、セットボタン長押し⑧荷重の小数点の位置をゼロボタンで設定後、セットボタン長押し⑨ゼロボタンを長押し、LEDを点灯させたら完了",
"圧力治具",
"ロードセルアンプ",
"500Nロードセル",
"ヒータ温度は制御停止で測定する事",
"アンプ設定方法",
"5. 治具厚み計測を行う:【押込み量】:0.2mm、【荷重確認時間】:2s、【繰り返し回数】:3回、 【待機荷重】:50N設定、【ヘッド荷重】:50N【治具厚み計測】を押す",
"①-1 「品種データ」⇒「本圧着情報」⇒「本圧着条件」 本圧着速度:20mm/s①-2 「マシンデータ」⇒「本圧着部[P1]/[P2]」⇒「本圧ヘッド」 本圧着速度距離:1.0mm"
],
"WorkItems": [
"1. ロードセルとアンプを接続しアンプの設定を行う(治具取付け)",
"3. 本圧バックアップステージに治具をセットする",
"4. パラメータ確認",
"2. 【データ管理メニュー】-【マシンデータ編集】-【プロセスデータ荷重】-【プロセス確認荷重】-【P1】/【P2】-【ユーザー設定プロセス条件】-軸関係の退避を行う"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:本圧着部[P1]圧力測定"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "ロードセル",
"Size": "-",
"Other": "2kN"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "ロードセルアンプ",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "本圧圧力測定治具",
"Size": "-",
"Other": "FM-3796"
}
],
"Jigus": [
"使用治工具No.26,27,28"
]
} | [
{
"WorkName": "本圧着部[P1][P2]圧力測定1",
"QualityItem": "動作確認",
"ToolManageNo": "FM-3796",
"ToolName": "本圧圧力測定治具",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "本圧圧力測定治具",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
},
{
"WorkName": "本圧着部[P1][P2]圧力測定1",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "ロードセル",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "正常な事",
"Method": "ロードセル",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
},
{
"WorkName": "本圧着部[P1][P2]圧力測定1",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "ロードセルアンプ",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "正常な事",
"Method": "ロードセルアンプ",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "本圧着部[P1][P2]圧力測定2",
"Words": [
"①",
"②",
"③",
"⑤",
"⑥",
"⑦",
"④",
"6. ①【ヘッド原点位置移動】-②【隙間量移動】-③【はい】-④ロードセルをセット、 ⑤【微調整ボタンで】⑥【ヘッド下降上昇】で5N出力する高さをティーチ⑦【結果登録】で治具厚み計測完了",
"7. 【ヘッド荷重】:30、500、1000Nの 3条件を設定し【計測開始】",
"8. 前ページの測定ポイント計測後、【換算定数自動計算】を押し、 表の値を入力し、【計算実行】を押す",
"9. 結果登録後、再度30、500、1000Nを測定し事前データへ記入する"
],
"WorkItems": [],
"WorkPoints": [
"規格:入力値が100N未満は±10N、100N以上は±10%"
],
"Tolks": [],
"InspectionItems": [
"検査表①:本圧着部[P1]圧力測定"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "本圧着部[P1][P2]圧力測定2",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "入力値の±10Nもしくは±10%の大きい方",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "昇温確認",
"Words": [
"温度の上昇を確認",
"①【品種情報表示】を押す",
"③ACF貼付け情報画面(条件)",
"④仮圧着情報画面(条件)・・・部品データ内に有り",
"①メイン画面【メンテナンスメニュー】",
"⑤本圧着情報画面(条件)",
"③【貼付/仮圧着温度】・・・選択し制御開始を押す",
"②各工程条件確認",
"④【本圧着温度/バックアップステージ】・・・選択し制御開始を押す",
"※プログラム名:17-IC-ACC-P1P2(本圧ヘッド本数)",
"※プログラム名:17-TCP-ACC-P1P2(本圧ヘッド本数)",
"IC仕様",
"TCP仕様",
"②【プロセスチェック】"
],
"WorkItems": [
"1. TEGプログラムを選択",
"2. プログラム内のデータ確認(上記データ選択後)",
"3. 各ヒータの昇温確認",
"4. 各工程の昇温確認ができれば完了"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:昇温確認"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "昇温確認",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "昇温する事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "最終平面確認",
"Words": [
"③荷重:130N 時間:0.1s",
"④ヘッド選択",
"⑤計測開始",
"①プロセス確認メニュー",
"②平行度確認",
"感圧紙=3L",
"感圧紙=3L",
"感圧紙=2L保護シート:カプトンシート(t80μm)",
"調整ボルト×4箇所",
"調整ボルト固定用セットビスを緩める事",
"調整ボルト×4箇所",
"調整ボルト固定用セットビスを緩める事",
"調整ボルト×2箇所",
"IC仕様",
"TCP仕様",
"ACF貼付け",
"仮圧",
"本圧",
"ACF貼付け ≪ヘッド先端部≫",
"仮圧 ≪ヘッド先端部≫",
"本圧 ≪ヘッドくさび≫"
],
"WorkItems": [
"1. 平面測定方法①【プロセス確認メニュー】-②【平行度確認】-③【【各工程を選択し下記条件を確認する】】-④【ヘッド選択】-⑤【計測開始】",
"3. 計測開始【規格:全面均一発色】",
"4. 調整方法・・・感圧紙の状態を確認し褐色状態が悪い(平面が出ていない)場合は下記を参照の上、調整を行う",
"2. 各工程条件"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:最終平面確認"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "最終平面確認",
"QualityItem": "平面度確認",
"ToolManageNo": "-",
"ToolName": "感圧紙",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "全面均一発色",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "ACF終端検出センサ調整",
"Words": [],
"WorkItems": [
"1. ACF終端検出センサー設定方法",
"2. ACF終端検出センサー調整方法"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:ACF終端検出センサ調整"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "ACF終端検出センサ調整",
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り設定されている事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "カッタ切込量調整",
"Words": [
"ACFが切れない方向",
"ACFが切れる方向",
"調整方法",
"①【ACF操作】を押す",
"②【ヘッド選択】-③【ACFフィード量】 -④【捨打ち】-⑤【ACF初期化】"
],
"WorkItems": [
"1. 操作方法",
"2. 切込み調整",
"3. 工具顕微鏡で確認する"
],
"WorkPoints": [
"切込量確認:ベーステープ厚み1/3の切込"
],
"Tolks": [],
"InspectionItems": [
"検査表①:カッタ切込量調整"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "工具顕微鏡",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26"
]
} | [
{
"WorkName": "カッタ切込量調整",
"QualityItem": "寸法確認",
"ToolManageNo": "-",
"ToolName": "工具顕微鏡",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "ベーステープ厚み1/3の切込",
"Method": "工具顕微鏡",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "踏残し量確認",
"Words": [
"ACF操作で捨打ちプレートへACFを貼付ける",
"カッター端面",
"ヘッドツール端面",
"10.85mm",
"①【ACF操作】を押す",
"※上記踏残量になるように調整を行う",
"①【データ管理メニュー】を押す",
"②【マシンデータ編集】を押す",
"③【[A]ACF貼付部】を選択し【貼付ヘッド】のL/Rを選択",
"④下図:ACFカッター基準位置L/Rの設定10.850mmの数値変更で踏残量を調整する"
],
"WorkItems": [
"1. 操作方法",
"2. 踏残し量を工具顕微鏡で確認",
"3. 調整方法"
],
"WorkPoints": [
"踏残し量:0.3~0.5mm",
"10.85mmより数値を下げた場合 ⇒ACF踏残量は増える10.85mmより数値を上げた場合 ⇒ACF踏残量は減る"
],
"Tolks": [],
"InspectionItems": [
"検査表①:踏残し量確認"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "工具顕微鏡",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26"
]
} | [
{
"WorkName": "踏残し量確認",
"QualityItem": "寸法確認",
"ToolManageNo": "-",
"ToolName": "工具顕微鏡",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "踏残し量0.3~0.5㎜",
"Method": "工具顕微鏡",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "ACF貼付け精度",
"Words": [
"下限センサONの事",
"X方向NG",
"精度NGの場合",
"①ヘッドとバックアップステージの間にパネルを挟み込む",
"条件は手投入で手取出しモード(ACF貼付けのみ)",
"②この時上図のように下限センサーがONするように調整",
"貼付条件(IC仕様) ・貼付長さ: 28.6mm(1ヶ所) 短辺側のみ ・温度: 120℃設定 ・荷重: 70N ・時間: 0.5s",
"貼付条件(TCP仕様) ・貼付長さ: 42mm(1ヶ所) 短辺側のみ ・温度: 120℃設定 ・荷重: 60N ・時間: 0.5s",
"①【生産モード設定】を押す",
"②【貼付項目】のみチェックする",
"①実際に実装したパネルを顕微鏡にて測定",
"②貼付け位置変更がなければ事前データに従い、指定の枚数のACF実装精度を測定する",
"※パネル、ACF、ICに起因する(誤差要因は含まない)",
"Y方向NG",
"ACFガイドローラの幅を再調整する"
],
"WorkItems": [
"1. ACF実装前設定",
"3. ACF実装確認",
"2. 設備をスタートしパネル投入のメッセージ に従い、パネルを投入する"
],
"WorkPoints": [
"ACF貼付け精度:X=±0.2mm/3σ Y=±0.1mm/3σ",
"※再調整が完了したら再度1)から作業をやり直しACF精度測定を実施する"
],
"Tolks": [],
"InspectionItems": [
"検査表①:ACF貼付け精度"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "2次元計測器",
"Size": "-",
"Other": "NIKON NEXIV"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "パネル",
"Size": "17インチTEG",
"Other": "TEG-17/1.1"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "ACF(IC仕様)",
"Size": "1.5㎜",
"Other": "AC-805A"
},
{
"JiguNo": "使用治工具No.29",
"ToolName": "ACF(TCP仕様)",
"Size": "1.5㎜",
"Other": "AC-11800RY-10"
}
],
"Jigus": [
"使用治工具No.26",
"使用治工具No.27,28",
"使用治工具No.27,29"
]
} | [
{
"WorkName": "ACF貼付け精度",
"QualityItem": "精度確認",
"ToolManageNo": "-",
"ToolName": "工具顕微鏡",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "X±0.2㎜/3σY±0.1㎜/3σ",
"Method": "工具顕微鏡",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "TCP操作盤説明",
"Words": [
"①",
"②",
"③",
"④",
"⑤",
"⑥",
"⑦",
"⑧",
"⑨",
"⑩",
"⑪",
"⑫",
"⑬",
"⑭",
"⑮",
"⑯",
"⑰",
"①OPERATION ENABLED 供給部操作盤有効SW②BUSY 点灯時、動作中③PART FEED〈FWD〉 1部品分正回転送り⑤PITCH FEED〈FWD〉 パーフォレーション1個分正回転送り⑥PITCH FEED〈REV〉 パーフォレーション1個分逆回転送り⑦SHORT FEED〈FWD〉 微小正回転送り⑧SHORT FEED〈REV〉 微小逆回転送り⑨POWER RESTORATION サーボONSW",
"⑩ERR RESET エラー解除SW⑪REEL〈UNREEL〉 供給側段差ローラ巻取り⑫REEL〈WIND〉 巻取側段差ローラ巻取り⑬TAPE HEAD SEARCH TCP頭出しSW⑭SCAN FEED TCPを打ち抜き位置まで送る⑮PUNCH CHECK 打ち抜き動作⑯TAPE PUSHER〈LOW〉 テープ下降高さへ移動⑰MOLD〈VAC/BLOW〉 金型吸着ON⇔OFF"
],
"WorkItems": [
"1. TCP供給部操作盤の説明は下記に記載"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "TCP操作盤説明",
"QualityItem": "操作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "TCP引き回し事前準備",
"Words": [
"①ストッパー×3個",
"②巻き取りリール×1個",
"③スペーサ×2個",
"④金型×1個",
"⑤TCPリール×2個",
"①③⑤",
"①③⑤",
"②",
"④",
"TCP供給部",
"③スペーサ",
"⑤TCPリール",
"①ストッパー",
"A",
"A"
],
"WorkItems": [
"1. 以下のTEG用ワークを用意する",
"2. 下記のようにTEG用ワークをセットする"
],
"WorkPoints": [
"A断面 詳細"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "TCP引き回し事前準備",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "TCP引き回し",
"Words": [
"供給側段差ローラ",
"巻取側段差ローラ",
"TCP",
"金型",
"4. 打ち抜く部品と金型の打ち抜き位置を大体合わせる",
"5. 微小送りで金型下ピンにパーフォレーションが合うようにする",
"3. 黄丸の段差ローラ部にて下限のセンサを切らないようにする",
"6. 調整後目視にてTCPの打ち抜き位置を確認",
"テープ下降時ピンが挿入していること"
],
"WorkItems": [
"1. OPERATION ENABLEDを押し操作盤を有効にする",
"2. TCPを下記のように引き回す"
],
"WorkPoints": [
"赤線:TCPの引き回し経路",
"青丸部金型周辺の詳細",
"操作盤の③④⑤⑥にて操作",
"操作盤⑪⑫にて巻き取り動作を行う",
"操作盤の⑦⑧にて微小送り ⑯にてテープ下降させ目視確認を行う",
"青線:保護テープの引き回し経路",
"ズレている場合操は作盤の③④⑤⑥にて位置を合わす。"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "TCP引き回し",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "TCP頭出しとバットマークセンサ調整",
"Words": [
"15回分巻き戻すとバットマークセンサ付近まで戻る",
"バッドマーク2",
"バッドマーク1",
"TEG用TCPにはICがない赤丸部の位置に当たる様に併せる",
"TCPのIC部にテープを貼る※センサを遮光するため",
"バッドマーク2が14.4mm頭出しセンサが99.9mmになるようにスケールを調整する",
"5mm",
"85.5mm"
],
"WorkItems": [
"1. 操作盤④を15回押す(TCPが15個分巻き戻す)",
"2. バッドマークセンサ2の位置をICのセンタに合わせる",
"3. 頭出しセンサをバッドマークセンサ1の位置を合わせる",
"4. スケールの位置を調整する。",
"5. アンプの設定を行う 下記参照",
"6. TCPにテープを貼る",
"7. 頭出し動作と送り動作を確認する",
"8. バッドマーク2のアンプ設定を行う"
],
"WorkPoints": [
"操作盤③でテープを貼ったTCPを頭出しセンサより後ろに戻す",
"操作盤⑬で頭出し動作開始",
"テープを貼ったTCPが頭出しセンサ位置にくればOK",
"操作盤⑭で送り動作開始",
"テープを貼ったTCPが打ち抜き位置にくればOK",
"打ち抜き位置が合わせた状態で実施すること",
"TCPを裏から見ている写真",
"バッドマーク2から頭出しセンサの位置85.5mm",
"バッドマーク2からバッドマークセンサの位置5mm",
"D on → L on"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "TCP頭出しとバットマークセンサ調整",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
},
{
"WorkName": "TCP頭出しとバットマークセンサ調整",
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り動作している事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "TCP打ち抜き精度確認",
"Words": [
"1. 打ち抜き精度を測定",
"キャッチャー",
"X1",
"X2",
"Y2",
"Y1"
],
"WorkItems": [],
"WorkPoints": [
"キャッチャーを入れる",
"操作盤⑮にて打ち抜き動作を行う",
"測定箇所",
"事前データに入力する",
"測定数:20枚",
"規格:X/Y=0.05mm/3σ"
],
"Tolks": [],
"InspectionItems": [
"検査表①:TCP打抜き精度確認"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "2次元計測器",
"Size": "-",
"Other": "NIKON NEXIV"
}
],
"Jigus": [
"使用治工具No.26"
]
} | [
{
"WorkName": "TCP打ち抜き精度確認",
"QualityItem": "精度確認",
"ToolManageNo": "-",
"ToolName": "工具顕微鏡",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "X0.05㎜/3σY0.05㎜/3σ",
"Method": "工具顕微鏡",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "IC仮圧着実装精度",
"Words": [
"2. 設備をスタートしパネル投入のメッセージ に従い、パネルを投入する",
"①【生産モード設定】を押す",
"②【貼付項目と仮圧着】にチェックする",
"条件は手投入で手取出しモード(ACF貼付けと仮圧着のみ)",
"※仮圧着オフセットはすべて「0」で実施",
"※パネル、ACF、ICに起因する(誤差要因は含まない)",
"実装条件 ・実装数: 1IC/パネル ・温度: 95℃設定 ・荷重: 50N ・時間: 0.1s",
"①実際に実装したパネルをNEXIVにて測定",
"②実装位置に変更がなければ事前データに従い 指定の枚数の仮圧着実装精度を測定する"
],
"WorkItems": [
"1. 仮圧実装前設定",
"3. 仮圧着実装確認"
],
"WorkPoints": [
"仮圧着実装精度X=2μm(レンジ)Y=2μm(レンジ)"
],
"Tolks": [],
"InspectionItems": [
"検査表①:仮圧着実装確認 IC実装"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "2次元計測器",
"Size": "-",
"Other": "NIKON NEXIV"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "パネル",
"Size": "17インチTEG",
"Other": "TEG-17/1.1"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "ACF",
"Size": "1.5㎜",
"Other": "AC-805A"
},
{
"JiguNo": "使用治工具No.29",
"ToolName": "IC",
"Size": "29.79x0.75",
"Other": "PSFS0001-CHIP(TBEX-C-0001)"
}
],
"Jigus": [
"使用治工具No.26",
"使用治工具No.27,28,29"
]
} | [
{
"WorkName": "IC仮圧着実装精度",
"QualityItem": "精度確認",
"ToolManageNo": "-",
"ToolName": "工具顕微鏡",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "X2μm(レンジ)Y2μm(レンジ)",
"Method": "工具顕微鏡",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "TCP仮圧着実装精度",
"Words": [
"2. 設備をスタートしパネル投入のメッセージ に従い、パネルを投入する",
"①【生産モード設定】を押す",
"②【貼付項目と仮圧着】にチェックする",
"条件は手投入で手取出しモード(ACF貼付けと仮圧着のみ)",
"※仮圧着オフセットはすべて「0」で実施",
"※パネル、ACF、ICに起因する(誤差要因は含まない)",
"実装条件 ・実装数: 1TCP/パネル ・温度: 90℃設定 ・荷重: 50N ・時間: 0.2s",
"①実際に実装したパネルをNEXIVにて測定",
"②実装位置に変更がなければ事前データに従い 指定の枚数の仮圧着実装精度を測定する"
],
"WorkItems": [
"1. 仮圧実装前設定",
"3. 仮圧着実装確認"
],
"WorkPoints": [
"仮圧着実装精度X=3μm(レンジ)Y=3μm(レンジ)"
],
"Tolks": [],
"InspectionItems": [
"検査表①:仮圧着実装確認 IC実装"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "2次元計測器",
"Size": "-",
"Other": "NIKON NEXIV"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "パネル",
"Size": "17インチTEG",
"Other": "TEG-17/1.1"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "ACF",
"Size": "1.5㎜",
"Other": "AC-11800RY-10"
},
{
"JiguNo": "使用治工具No.29",
"ToolName": "TCP",
"Size": "40 x 20",
"Other": "PFSC-48mm(1160104)"
}
],
"Jigus": [
"使用治工具No.26",
"使用治工具No.27,28,29"
]
} | [
{
"WorkName": "TCP仮圧着実装精度",
"QualityItem": "精度確認",
"ToolManageNo": "-",
"ToolName": "工具顕微鏡",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "X3μm(レンジ)Y3μm(レンジ)",
"Method": "工具顕微鏡",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "IC本圧着踏み位置調整",
"Words": [
"パネルマーク",
"水性マーカー",
"0.25mm",
"①17インチパネルに水性マジックで実装ラインにマーカー",
"②【生産モード設定】で本圧踏み位置用設定に変更",
"③【アドミニ拡張メニュー】-【ドライ運転カスタマイズ】設定",
"④【ドライ運転カスタマイズ】を最小化し消さない",
"①【通常通り設備スタート】を押す",
"②踏み位置確認実施",
"③【オフセット】を入力(基準値に踏み位置がくるように調整)"
],
"WorkItems": [
"1. 踏み位置確認前準備",
"2. 踏み位置確認実施"
],
"WorkPoints": [
"ツール汚れを保護する為必ず本圧着にテフロンシートをセットすること",
"本圧着ヘッド 踏み位置ヘッド間相対ずれ量(Y)=0.1mm以内"
],
"Tolks": [],
"InspectionItems": [
"検査表①:本圧着実装精度 IC実装"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "工具顕微鏡",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "パネル",
"Size": "17インチ",
"Other": "TEG-17/1.1"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "本圧着テフロン",
"Size": "-",
"Other": "50μm厚"
},
{
"JiguNo": "使用治工具No.29",
"ToolName": "黒マジック",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26",
"使用治工具No.27,28,29"
]
} | [
{
"WorkName": "IC本圧着踏み位置調整",
"QualityItem": "精度確認",
"ToolManageNo": "-",
"ToolName": "工具顕微鏡",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "ヘッド間相対ずれ量Y0.1㎜以内",
"Method": "工具顕微鏡",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "IC本圧着実装精度",
"Words": [
"2. 設備をスタートしパネル投入のメッセージ に従い、パネルを投入する",
"本圧着実装精度X=±3μm/3σY=±3μm/3σ",
"①【生産モード設定】を押す",
"②【貼付、仮圧着、本圧着】にチェックする",
"条件は手投入で手取出しモード(ACF貼付けと仮圧着と本圧着のみ)",
"※パネル、ACF、ICに起因する(誤差要因は含まない)",
"実装条件 ・実装数: 1IC/パネル ・温度: ガラスバックアップ 260℃設定 SUSバックアップ 310℃設定 ・荷重: 350N ・時間: 5.0s",
"IC Mark Center",
"Panel Mark Center",
"IC Mark",
"Panel Mark",
"IC Mark Center",
"Panel Mark Center",
"IC Mark",
"Panel Mark",
"①実際に実装したパネルをNEXIVにて測定",
"②実装位置に変更がなければ事前データに従い 指定の枚数の本圧着実装精度を測定する"
],
"WorkItems": [
"3. 本圧着実装確認",
"1. 本圧実装前設定"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:本圧着実装精度 IC実装"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "2次元計測器",
"Size": "-",
"Other": "NIKON NEXIV"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "パネル",
"Size": "17インチTEG",
"Other": "TEG-17/1.1"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "ACF",
"Size": "1.5㎜",
"Other": "AC-805A"
},
{
"JiguNo": "使用治工具No.29",
"ToolName": "IC",
"Size": "29.79×0.75×0.17t",
"Other": "PSFS0001-CHIP"
},
{
"JiguNo": "使用治工具No.30",
"ToolName": "本圧着テフロン",
"Size": "-",
"Other": "50μm厚"
}
],
"Jigus": [
"使用治工具No.26",
"使用治工具No.27,28,29,30"
]
} | [
{
"WorkName": "IC本圧着実装精度",
"QualityItem": "精度確認",
"ToolManageNo": "-",
"ToolName": "工具顕微鏡",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "X3μm/3σY3μm/3σ",
"Method": "工具顕微鏡",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "TCP本圧着踏み位置調整",
"Words": [
"パネルマーク",
"水性マーカー",
"0.25mm",
"①17インチパネルに水性マジックで実装ラインにマーカー",
"②【生産モード設定】で本圧踏み位置用設定に変更",
"③【アドミニ拡張メニュー】-【ドライ運転カスタマイズ】設定",
"④【ドライ運転カスタマイズ】を最小化し消さない",
"①【通常通り設備スタート】を押す",
"②踏み位置確認実施",
"③【オフセット】を入力(基準値に踏み位置がくるように調整)"
],
"WorkItems": [
"1. 踏み位置確認前準備",
"2. 踏み位置確認実施"
],
"WorkPoints": [
"ツール汚れを保護する為必ず本圧着にテフロンシートをセットすること",
"本圧着ヘッド 踏み位置ヘッド間相対ずれ量(Y)=0.1mm以内"
],
"Tolks": [],
"InspectionItems": [
"検査表①:本圧着実装精度 TCP実装"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "工具顕微鏡",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "パネル",
"Size": "17インチ",
"Other": "TEG-17/1.1"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "本圧着テフロン",
"Size": "-",
"Other": "50μm厚"
},
{
"JiguNo": "使用治工具No.29",
"ToolName": "黒マジック",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26",
"使用治工具No.27,28,29"
]
} | [
{
"WorkName": "TCP本圧着踏み位置調整",
"QualityItem": "精度確認",
"ToolManageNo": "-",
"ToolName": "工具顕微鏡",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "ヘッド間相対ずれ量Y0.1㎜以内",
"Method": "工具顕微鏡",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "TCP本圧着実装精度",
"Words": [
"2. 設備をスタートしパネル投入のメッセージ に従い、パネルを投入する",
"本圧着実装精度X=±5μm/3σY=±5μm/3σ",
"①【生産モード設定】を押す",
"②【貼付、仮圧着、本圧着】にチェックする",
"条件は手投入で手取出しモード(ACF貼付けと仮圧着と本圧着のみ)",
"※パネル、ACF、ICに起因する(誤差要因は含まない)",
"実装条件 ・実装数: 1TCP/パネル ・本圧着ツール温度: ガラスバックアップ 230℃設定 SUSバックアップ 290℃設定 ・荷重: 180N ・時間: 5.0s",
"IC Mark Center",
"Panel Mark Center",
"IC Mark",
"Panel Mark",
"IC Mark Center",
"Panel Mark Center",
"IC Mark",
"Panel Mark",
"①実際に実装したパネルをNEXIVにて測定",
"②実装位置に変更がなければ事前データに従い 指定の枚数の本圧着実装精度を測定する"
],
"WorkItems": [
"3. 本圧着実装確認",
"1. 本圧実装前設定"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:本圧着実装精度 TCP実装"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "2次元計測器",
"Size": "-",
"Other": "NIKON NEXIV"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "パネル",
"Size": "17インチTEG",
"Other": "TEG-17/1.1"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "ACF",
"Size": "1.5㎜",
"Other": "AC-11800RY-10"
},
{
"JiguNo": "使用治工具No.29",
"ToolName": "TCP",
"Size": "40×20×0.05t",
"Other": "PABD-48mm"
},
{
"JiguNo": "使用治工具No.30",
"ToolName": "本圧着テフロン",
"Size": "-",
"Other": "50μm厚"
}
],
"Jigus": [
"使用治工具No.26",
"使用治工具No.27,28,29,30"
]
} | [
{
"WorkName": "TCP本圧着実装精度",
"QualityItem": "精度確認",
"ToolManageNo": "-",
"ToolName": "工具顕微鏡",
"ToolCycle": "1回/年",
"ToolRecord": "校正成績書",
"StdVal": "X5μm/3σY5μm/3σ",
"Method": "工具顕微鏡",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "搬送確認",
"Words": [
"生産管理内データを搬送確認する前に一旦初期化を行う",
"事前データ取りデータ数:20枚",
"クリック後、指示に従いデータを添付",
"①生産モード設定でチェックをずべて外し、『手投入・手取出し』のパネル搬送モードにする",
"②生産管理情報内のエラーログを全消去する",
"③搬送枚数指定を行う【品種切替】 - 【生産予定数】 - 【【20枚】】に設定する",
"④事前データに記入(英語画面に変更)",
"⑤言語切替:【メンテナンス】 - 【言語切替】 - 【英語】",
"⑥データ添付方法1【下記部をハードコピー】する",
"⑦データ添付方2【下記部をハードコピー】する",
"⑧事前データへ添付する",
"※上記画面をSDカードへハードコピーする",
"※上記画面をSDカードへハードコピーする",
"※④の指示従いデータを添付する"
],
"WorkItems": [
"1. 搬送確認をする"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:搬送確認(20枚)"
],
"InspectionNos": [
"WWYJ-5500-002"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "パネル",
"Size": "17インチTEG",
"Other": "TEG-17/1.1"
}
],
"Jigus": [
"使用治工具No.26"
]
} | [
{
"WorkName": "搬送確認",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "タクト測定",
"Words": [
"設備平均値を入力",
"4IC2辺実装時\u000b IC実装 7.5s/サイクル TCP実装 7.5s/サイクル",
"①ドライ運転モード選択",
"【メンテナンス】-【ドライ運転;カスタマイズ】【ACF貼付動作L】【ACF貼付動作R】:自動",
"②【ACTIVATION SW】 + 【START SW】 を押し、OKで運転開始",
"③言語切替:【メンテナンス】 - 【言語切替】 - 【英語】",
"④データ採取【生産管理】-【サイクルタイム履歴】",
"⑤【サイクルタイム履歴】をハードコピーする",
"⑥事前データに添付する"
],
"WorkItems": [
"1. タクト測定をする"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:タクト測定"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "タクト測定",
"QualityItem": "時間確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "7.5s/サイクル",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "非常停止SW動作確認",
"Words": [
"①非常停止SWを押し、警告が発生すること",
"参考(正流れ)前面",
"参考(正流れ)背面",
"②\"非常停止中\"警告を画面上で確認する",
"③非常停止SWを解除後設備が復旧すること"
],
"WorkItems": [
"■1. 各非常停止スイッチの動作確認をする"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:非常停止SW動作確認"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業",
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "非常停止SW動作確認",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "カバーロック動作確認(本体部AM)",
"Words": [
"マシン動作中にカバーを開けようとすると、シリンダロックがかかって開かないこと安全スイッチインターロックが働いてマシンが停止しないこと"
],
"WorkItems": [
"■1. カバーロックスイッチの動作確認をする"
],
"WorkPoints": [
"全ての開閉カバーで実施する"
],
"Tolks": [],
"InspectionItems": [
"検査表①:カバーロック動作確認"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業",
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "カバーロック動作確認(本体部AM)",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "カバーロック動作確認(TCP供給部)",
"Words": [
"マシン動作中にカバーを開けようとすると、シリンダロックがかかって開かないこと安全スイッチインターロックが働いてマシンが停止しないこと",
"背面カバーロック"
],
"WorkItems": [
"■1. カバーロックスイッチの動作確認をする"
],
"WorkPoints": [
"全ての開閉カバーで実施する"
],
"Tolks": [],
"InspectionItems": [
"検査表①:カバーロック動作確認"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業",
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "カバーロック動作確認(TCP供給部)",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "カバーロック動作確認(本体部P1P2)",
"Words": [
"マシン動作中にカバーを開けようとすると、シリンダロックがかかって開かないこと安全スイッチインターロックが働いてマシンが停止しないこと"
],
"WorkItems": [
"■1. カバーロックスイッチの動作確認をする"
],
"WorkPoints": [
"全ての開閉カバーで実施する"
],
"Tolks": [],
"InspectionItems": [
"検査表①:カバーロック動作確認"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業",
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "カバーロック動作確認(本体部P1P2)",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "カバー安全SW動作確認",
"Words": [
"AM",
"P1",
"P2",
"AM",
"TCP"
],
"WorkItems": [
"■1. 各カバー(扉)を開けて全軸原点復帰動作をさせ安全SWの動作を確認する"
],
"WorkPoints": [
"カバー(扉)を開け状態では安全SWが働きマシンが動作しないこと",
"A_前面LR扉2枚(安全SW_2箇所)",
"M_前面LR扉2枚(安全SW_2箇所)",
"P1_前面LR扉2枚(安全SW_2箇所)",
"P2_前面LR扉2枚(安全SW_2箇所)",
"M_背面 供給部切替用扉2枚(安全SW_1箇所)",
"M_背面 IC供給後上下扉2枚(安全SW_2箇所)",
"TCP供給部:扉3枚(安全SW_3箇所)"
],
"Tolks": [],
"InspectionItems": [
"検査表①:カバー安全SW動作確認"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "カバー安全SW動作確認",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "連結動作確認",
"Words": [
"コネクタ名称 DIREMGR(6PIN):上下流非常停止 DIRSFR(6PIN):上下流カバー",
"コネクタを抜く → LED点滅コネクタを挿入し『POWER RESTTATION』を押す → LED点灯(パワー復帰)",
"治具ショートコネクタ",
"治具ケーブル(※上流/下流と2種類あるので注意すること)",
"接続するケーブル上流側:CNF下流側:CNB",
"接続するケーブル上流側:COVUOR下流側:COVDOR",
"正流れ",
"逆流れ",
"MR前面カバー開閉時、ON/OFF",
"下流前面カバー開閉時、ON/OFF",
"AM前面カバー開閉時、ON/OFF",
"上流前面カバー開閉時、ON/OFF",
"非常停止ON/OFF、ON/OFF",
"非常停止ON/OFF、ON/OFF"
],
"WorkItems": [
"■1. 上下流装置⇒自設備への信号確認",
"1. 治具ショートコネクタを上下流連結コネクタに接続する",
"2. 治具ショートコネクタの非常停止及びカバーのコネクタをそれぞれ抜き差し信号確認を行う",
"■2. 自設備⇒上下流装置への信号確認",
"1. 治具ケーブルを上下流連結コネクタに接続する",
"3.非常停止を押す/前面カバーを開け閉めを行い連結信号の確認を行う"
],
"WorkPoints": [
"すべてのカバーSW&非常停止SWを閉にし、パワー復帰を行い、パワー復帰ランプが「点灯」している状態で以下の作業を行うこと",
"実際に検査してみて必要があれば差し替え"
],
"Tolks": [],
"InspectionItems": [
"検査表①:連結動作確認",
"検査表①:連結動作確認"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業",
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "連結動作確認",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "事前データ確認",
"Words": [
"~",
"①事前データの最終まとめを行う",
"※仕様欄の記入モレや空欄無い事",
"②お客様要望対応",
"お客様特殊仕様でデータの追加がある場合は営業/技術含めフォーマットを作成し事前データに添付する"
],
"WorkItems": [
"1. 事前データの確認をする"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:事前確認"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "事前データ確認",
"QualityItem": "確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "設備エージング設定",
"Words": [
"選択データ:「040.ドライ運転動作選択」を\"供給部特殊\"に設定",
"「IH」軸が表示されていればOKです",
"出荷用エージングIC動作(TCP時のみ有効):有",
"★このエージング手順はIC/TCPの両供給部を動作させるモードです。基本はこの手順に沿ってエージング行ってください。\u000bやむを得ない場合((IC供給用移載ヘッドが付いている・併設機でない)は通常のTEG実装用データにてエージングをかけてください。\u000b但し、必ずどちらの供給部も最低10hは動作させること。"
],
"WorkItems": [
"1. TCP供給部で動作可能な状態にする",
"2. システムパラメータを変更する",
"3. オペレーション OFF ⇒ ON して再起動する",
"4. ドライ運転カスタマイズ画面でIC供給部エージングを有効にします"
],
"WorkPoints": [
"※終了せず、\"最小化\"します。終了すると、設定が解除されます"
],
"Tolks": [],
"InspectionItems": [
"検査表①:設備エージング"
],
"InspectionNos": [],
"WorkTypes": [
"★静電対策作業",
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "設備エージング設定",
"QualityItem": "操作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "設備エージング",
"Words": [
"※出荷に必要なエージング時間:30H以上(製造元含めて30H以上)※エラー無き事",
"①ドライ運転モード選択",
"②【ACTIVATION SW】 + 【START SW)を押し、OKで運転開始",
"③エージング時間の確認",
"【メンテナンスメニュー】 ⇒ 【アワーメーター表示】",
"動作概要: 通常のTCP生産動作+TEG IC/トレイのデータによる、ITX軸、ITY軸、 ITV軸、IH軸の生産動作を行います。 ※TEG IC/トレイのデータ、供給部情報は表示されません。",
"<終了後の手順>",
"①ドライ運転カスタマイズ画面を終了する",
"②システムパラメータを元の値(搭載指示書の値)に戻す",
"③オペレーション OFF ⇒ ON して再起動する",
"④出荷エージング設定が解除されていることを確認する 「IH」軸が表示されていなければOKです"
],
"WorkItems": [
"1. 設備のエージングを行う"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:設備エージング"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "設備エージング",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "30H以上エラーなし",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "出荷認定(自主検査書確認)",
"Words": [
"①自主検査書確認",
"※自主検査書を基に設備確認を行う",
"②出荷認定",
"工程品質:出荷認定者による出荷認定を実施"
],
"WorkItems": [
"1. 出荷認定を行う"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:製造チェックリスト確認"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "出荷認定(自主検査書確認)",
"QualityItem": "確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造チェックリスト",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "ソフトウェア搭載指示書設定・確認",
"Words": [
"①ソフトウェア搭載指示書を基に設備設定・確認を行う",
"※搭載指示書は技術発行",
"②設備設定・確認【データ管理メニュー】-【システム設定】",
"③下記青マーク内に搭載指示書設定する箇所有り",
"④ソフトウェア搭載指示書の設定と確認が完了したら搭載指示書をPDFで所定の出荷フォルダに保管する事"
],
"WorkItems": [
"1. ソフトウェア搭載指示書通りに設定・確認をする"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:ソフトウェア搭載指示書設定・確認"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "ソフトウェア搭載指示書設定・確認",
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-002",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "銘板シール貼付け①(定格銘板、真空シール、RoHSシール、CEシール、シリアルNo.)",
"Words": [
"TCP供給部背面",
"本圧着部背面",
"※正流れ",
"※逆流れ",
"※TCP供給ありの場合のみ",
"※P2ありの場合のみ",
"正流れ",
"逆流れ",
"15mm",
"5mm",
"10mm",
"13.5mm",
"13.5mm",
"【シール貼付け寸法_正逆共通】",
"70㎜"
],
"WorkItems": [
"■1. 設備後部、定格銘板貼付確認の実施"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"本体検査表①:銘板シール貼付け",
"定格銘板キット検査表②:貼付位置確認 (正逆)"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業",
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "銘板シール貼付け①(定格銘板、真空シール、RoHSシール、CEシール、シリアルNo.)",
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolName": "スケール",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "寸法の位置に貼付けている事",
"Method": "スケール",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
},
{
"WorkName": "銘板シール貼付け①(定格銘板、真空シール、RoHSシール、CEシール、シリアルNo.)",
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolName": "スケール",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "寸法の位置に貼付けている事",
"Method": "スケール",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "本体検査(001-048)",
"WorkName": "銘板シール貼付け②(トランスタップ設定表示ラベル)",
"Words": [
"正流れ",
"逆流れ",
"85㎜",
"15mm",
"※お客様工場電源の仕様確認後、貼付け",
"85㎜",
"15mm"
],
"WorkItems": [
"■1. 設備後部、定格銘板貼付確認"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"本体検査表①:銘板シール貼付け",
"定格銘板キット検査表②:貼付位置確認 (正逆)"
],
"InspectionNos": [],
"WorkTypes": [
"■安全作業",
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "銘板シール貼付け②(トランスタップ設定表示ラベル)",
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolName": "スケール",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "寸法の位置に貼付けている事",
"Method": "スケール",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
},
{
"WorkName": "銘板シール貼付け②(トランスタップ設定表示ラベル)",
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolName": "スケール",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "寸法の位置に貼付けている事",
"Method": "スケール",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "設備エージング",
"Words": [
"※出荷に必要なエージング時間:30H以上(製造元含めて30H以上)※エラー無き事",
"FPX007CG/FP",
"FPX007CG/FP",
"FPX007CG/FP",
"FPX007CG/FP",
"操作画面①",
"操作画面②",
"操作画面③",
"操作画面④",
"操作画面⑤"
],
"WorkItems": [
"1. 設備のエージング確認"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:エージング確認"
],
"InspectionNos": [
"WWYJ-5500-004"
],
"WorkTypes": [],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "設備エージング",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事エージング時間:30時間以上",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "ソフトウェア搭載指示書設定・確認",
"Words": [
"FPX007CG/FP",
"FPX007CG/FP",
"確認画面表示操作①",
"確認画面表示操作①"
],
"WorkItems": [
"1. ソフトウェア搭載指示書通りに設定・確認をする"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:ソフト搭載指示書確認"
],
"InspectionNos": [
"WWYJ-5500-004"
],
"WorkTypes": [],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "ソフトウェア搭載指示書設定・確認",
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "最終のソフト搭載指示書にて確認、指示通り設定されている事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "個別仕様/選択仕様確認",
"Words": [],
"WorkItems": [
"1. 仕様チェックリストを基に仕様確認を行う(集約仕様書を参照の上、仕様確認)"
],
"WorkPoints": [
"※お客様個別に設備仕様が異なるので工事機番を間違えないよう集約仕様書を基に確認を行う事"
],
"Tolks": [],
"InspectionItems": [
"検査表①:設備仕様書確認"
],
"InspectionNos": [
"WWYJ-5500-004"
],
"WorkTypes": [],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "個別仕様/選択仕様確認",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "仕様書を基に、実機が最終の仕様通りになっている事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "工程検査書の最終確認",
"Words": [],
"WorkItems": [
"1. 工程検査書の完了を確認する"
],
"WorkPoints": [
"総合判定にNGが無きこと",
"未記入が無きこと"
],
"Tolks": [],
"InspectionItems": [
"検査表①:工程検査書の最終確認"
],
"InspectionNos": [
"WWYJ-5500-004"
],
"WorkTypes": [],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "工程検査書の最終確認",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "検査項目にモレがなく工程検査表が完了している事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "成績書の確認実施",
"Words": [],
"WorkItems": [
"1. 事前データが完了したら下図の資料:成績書を作成する"
],
"WorkPoints": [
"機種を選択する",
"仕様書に書かれている正式なお客様名を記入",
"全角入力のこと",
"月日の記入にてスペースを2つ入れ、十の桁で0は使わない",
"○:良 2012.9.3 ×:悪 2012.09.03",
"全角入力のこと",
"全角入力のこと※月日の記入にてスペースを1つ入れ、十の桁で0は使わない",
"★作成後、担当に印を押す ※PSFS:担当者 ※製作先:PSFSより認定書を発行されている作業者★上記、担当印を押したら、検印者へ渡し検印をもらう"
],
"Tolks": [],
"InspectionItems": [
"検査表①:成績書の確認実施"
],
"InspectionNos": [
"WWYJ-5500-004"
],
"WorkTypes": [
"★静電対策作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "成績書の確認実施",
"QualityItem": "操作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "成績書が作成されている事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
},
{
"WorkName": "成績書の確認実施",
"QualityItem": "操作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "成績書が検印者へ提出されている事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "工程カルテ確認",
"Words": [
"機種 FPX007CG/FP"
],
"WorkItems": [
"1. 工程カルテにて工程検査者からの引継ぎを確認すると共に完了の確認も行う"
],
"WorkPoints": [
"※完了していない場合は、残件の作業を行い、完了に担当印を押す",
"★最後に右上に印を押す",
"①すべての項目が完了しているか確認し、終わっていなければ作業実施し完了させる②作業完了後は作業者の印を押す"
],
"Tolks": [],
"InspectionItems": [
"検査表①:工程カルテ確認"
],
"InspectionNos": [
"WWYJ-5500-004"
],
"WorkTypes": [
"★静電対策作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "工程カルテ確認",
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "工程カルテ記載内容が完了している事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "出荷認定(自主検査書確認)",
"Words": [
"【製造出荷用】FPX007CG/FP自主検査チェック表"
],
"WorkItems": [
"1. 自主検査書を基に設備確認を行う",
"2. 出荷認定を行う"
],
"WorkPoints": [
"工程品質:出荷認定者による出荷認定を実施"
],
"Tolks": [],
"InspectionItems": [
"検査表①:出荷認定"
],
"InspectionNos": [
"WWYJ-5500-004"
],
"WorkTypes": [],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "出荷認定(自主検査書確認)",
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "出荷認定に必要な書類が完了している事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "電源OFF前(付属品撤去)",
"Words": [
"※お客様ワーク時個数管理しているので、廃棄せず、個数分を返却する事(返却はお客様管理室へ)",
"①トレイの撤去",
"②本圧着保護シートの撤去",
"③テープ廃棄BOX内の清掃",
"④ACF取外し"
],
"WorkItems": [
"1. 設備内の付属品を撤去する"
],
"WorkPoints": [
"※供給部トレイはすべて撤去",
"※BOX内を清掃",
"※ACFユニットのACFを取り外す"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "電源OFF前(付属品撤去)",
"QualityItem": "外観確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "付属品が設備から撤去されている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "バックアップステージガラス有無確認(欠け確認)",
"Words": [
"<本圧着フレーム部前面>",
"本圧着バックアップベース",
"ACF工程部バックアップガラス確認",
"仮圧着工程部バックアップガラス確認",
"本圧着工程部バックアップガラス確認",
"※写真:標準SUSバックアップ",
"※写真:標準SUSバックアップ"
],
"WorkItems": [
"1. 各工程バックアップステージのガラス仕様の確認",
"2. ガラスの欠け確認をする"
],
"WorkPoints": [
"※欠けがあった場合は速やかに部品交換を実施する(出荷に間に合わない場合は関連部署に連絡の上、手配)"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "バックアップステージガラス有無確認(欠け確認)",
"QualityItem": "外観確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "バックアップガラスの欠け無き事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "SDへのデータ保存",
"Words": [
"SDラベル",
"①【データ管理メニュ】 - 【バックアップリストア】",
"②【保存ドライブ】 - 【フォルダ作成】 - 【Ser№】 - 【バックアップ開始】",
"③保存が完了したらXドライブへ格納",
"FPX007CG/FP",
"FPX007CG/FP"
],
"WorkItems": [
"1. 付属品のSDカードに設備データを保存する",
"2. SDカードにラベルを貼付ける"
],
"WorkPoints": [
"※SDカード書込みLOCKをする事!!"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "SDへのデータ保存",
"QualityItem": "操作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "環境切替の設定",
"Words": [
"操作①",
"FPX007CG/FP",
"操作②",
"操作③",
"操作④"
],
"WorkItems": [
"1. 環境切替の設定を実施 (アドミニ設定 → 操作レベル0へ)"
],
"WorkPoints": [
"※上記設定後、一度PAWER OFFし、 設定が指示通り完了しているか確認 (解除方法は、上記の右項目:アドミニレベル設定へ)"
],
"Tolks": [],
"InspectionItems": [
"検査表①:環境切替の設定"
],
"InspectionNos": [
"WWYJ-5500-004"
],
"WorkTypes": [],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "環境切替の設定",
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "操作レベル0に設定されている事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "1次検印者へ検印依頼/言語の設定",
"Words": [
"①",
"②",
"FPX007CG/FP"
],
"WorkItems": [
"1. 1次検印者への依頼",
"2. 仕様書に基づき言語を設定する"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:1次検印者へ検印依頼",
"検査表①:1次検印者へ検印依頼"
],
"InspectionNos": [
"WWYJ-5500-004"
],
"WorkTypes": [],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "1次検印者へ検印依頼/言語の設定",
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "検印依頼が実施されている事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
},
{
"WorkName": "1次検印者へ検印依頼/言語の設定",
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "仕様書通りの言語設定がされている事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "インターロックSW確認/シュートピンの排除確認",
"Words": [],
"WorkItems": [
"1. 上下流のインターロックショートピンを取り外す"
],
"WorkPoints": [
"R側を取り外す",
"L側を取り外す"
],
"Tolks": [],
"InspectionItems": [
"検査表①:インターロックSW確認"
],
"InspectionNos": [
"WWYJ-5500-004"
],
"WorkTypes": [],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "インターロックSW確認/シュートピンの排除確認",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "インターロック信号等がショートされてい無い事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "HEPAファン動作確認",
"Words": [],
"WorkItems": [
"1. 設備上面HEPAファンのダイヤル設定する",
"2. SWを\"RUN\"にする事でHEPAが回転することを確認する"
],
"WorkPoints": [
"ダイヤル\"10\"に設定する",
"回転が確認できたらフィルター汚れ防止の為 \"STOP\" にする事",
"STOP"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "HEPAファン動作確認",
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "正常な事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "タップ切替",
"Words": [
"専用のマイナスドライバーを使用"
],
"WorkItems": [
"1. 電源OFF前に設備 \"原点復帰\" を行う",
"2. 一次側電源ケーブルを抜く",
"3. 設備後面電源カバーを+ドライバーにてビスを外しカバーを取る",
"4. 電源カバー端子台電源ケーブルを外し上面の丸穴より電源ケーブルを抜き所定位置へ返却",
"5. カバーを元に戻す",
"■6. 設備前カバー外しトランス内のタップ切替を行う"
],
"WorkPoints": [
"※通電中は絶対にタップに触れないこと",
"※一次側電源ケーブルを抜く",
"※通電中表示が無いことを確認する",
"※タップ切替時の電圧指定は集約仕様書を参照し間違えないように注意する"
],
"Tolks": [],
"InspectionItems": [
"検査表①:トランスタップ切替",
"検査表①:電源OFF前設備原点復帰",
"検査表①:電源OFF電圧タップ切り替え確認"
],
"InspectionNos": [
"WWYJ-5500-004"
],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "タップ切替",
"QualityItem": "原点確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "原点位置である事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
},
{
"WorkName": "タップ切替",
"QualityItem": "操作確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "1次電源が取り外されている事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
},
{
"WorkName": "タップ切替",
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "集約仕様書の出荷先仕様電圧を確認する事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"静電対策工程"
]
},
{
"WorkName": "タップ切替",
"QualityItem": "配線確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り配線されている事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "電圧切替シール貼付",
"Words": [
"NOCONNECTION",
"※タップ切替時の電圧指定は集約仕様書を参照し間違えないように注意をする"
],
"WorkItems": [
"■1. タップ電圧シール貼付け",
"2. 作業終了後、必ず第3者チェックをする事"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:電圧切替シール貼付",
"検査表①:電圧切替シール貼付"
],
"InspectionNos": [
"WWYJ-5500-004"
],
"WorkTypes": [
"■安全作業",
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "電圧切替シール貼付",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "梱包準備",
"Words": [],
"WorkItems": [
"1. 設備内のゴミ、指紋を取る",
"2. 上流/下流機の連結バラシ",
"3. 梱包台車を設備横まで持ってくる"
],
"WorkPoints": [
"※SUSのブラケットやカバーなどは指紋が目立つので必ずふきとる事",
"※設備内にTCP等お客様の部材は絶対無い事"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "梱包準備",
"QualityItem": "外観確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "汚れ・キズ・設備内部材無い事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "HDD取外し",
"Words": [
"①作業者のリストストラップ着用",
"②本体アース板(左前)にリストストラップを取付ける(工場アース)",
"③FAパソコン前面カバーを取外す",
"④HDDを取外し、メーカー専用ケースで梱包する(付属品)"
],
"WorkItems": [
"★1. 設備前面下カバーを外し、本体よりHDDを取外し梱包する"
],
"WorkPoints": [
"リストラップは日常点検で確認していること(800kΩ以上9MΩ以内)",
"※ハードディスクは2個あるので写真○の箇所にL,Rを記載"
],
"Tolks": [],
"InspectionItems": [
"検査表①:HDD取外し"
],
"InspectionNos": [
"WWYJ-5500-004"
],
"WorkTypes": [
"★静電対策作業",
"★静電対策作業",
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "リストストラップ",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26"
]
} | [
{
"WorkName": "HDD取外し",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "リストストラップ",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "指示通り取り外し出来ている事",
"Method": "目視",
"RecordMethod": "WWYJ-5500-004",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "HEPAファン設定確認",
"Words": [
"①強弱ダイヤル確認",
"②運転SW確認"
],
"WorkItems": [
"1. 設備上面HEPAファンの設定を確認する"
],
"WorkPoints": [
"ダイヤル\"10\"",
"RUN"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "HEPAファン設定確認",
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り設定されている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "本圧着部P1、P2架台切り離し①(AM-P1連結ケーブル、配管)",
"Words": [
"AM",
"P1",
"P2",
"AM前面",
"P1前面",
"①CPUーBOX",
"②AM 連結コネクタブラケット",
"③P1 RING負荷(K3011)",
"P2",
"①",
"②",
"③",
"P1からの配管接続",
"※正流れ連結"
],
"WorkItems": [
"1. 前面カバーを開けAM-P1間の連結ケーブル、配管をすべて取り外す",
"2.取り外した連結ケーブル、配管はエアーマットで 保護する(P1架台)"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "本圧着部P1、P2架台切り離し①(AM-P1連結ケーブル、配管)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り切り離し出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "本圧着部P1、P2架台切り離し②(P1-P2連結ケーブル、配管)",
"Words": [
"AM",
"P1",
"P2",
"P2",
"①",
"②",
"③",
"P1背面",
"P1前面",
"①P1背面RING負荷K3003",
"② P1連結コネクタブラケット",
"③ P1 RING負荷(K300A)",
"P2前面",
"P2からの配管",
"P1(背面)",
"※正流れ連結"
],
"WorkItems": [
"1. 前面、背面カバーを開けP1-P2間の連結ケーブル、配管をすべて取り外す",
"2.取り外した連結ケーブル、配管はエアーマットで 保護する(P2架台)"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "本圧着部P1、P2架台切り離し②(P1-P2連結ケーブル、配管)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り切り離し出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "本圧着部P1、P2架台切り離し③(連結ブロック、パネル搬送部)",
"Words": [
"AM",
"P1",
"P2",
"架台上面図"
],
"WorkItems": [
"1.AM-P1間 P1-P2間の連結ブロックを切り離す",
"2.パネル搬送部固定ねじ取外し(架台間をまたいで連結している箇所)"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "レンチ",
"Size": "4㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "レンチ",
"Size": "3㎜",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26",
"使用治工具No.27"
]
} | [
{
"WorkName": "本圧着部P1、P2架台切り離し③(連結ブロック、パネル搬送部)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り切り離し出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "本圧着部P1、P2架台切り離し④(架台)",
"Words": [
"P1",
"AM",
"P2",
"P1",
"AM",
"P2"
],
"WorkItems": [
"1.P2架台側面にミックを差込み、架台を持ち上げてP2架台を切り離す。",
"1.P1架台側面にミックを差込み、架台を持ち上げてP1架台を切り離す。"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "ミック",
"Size": "3t",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26",
"使用治工具No.26"
]
} | [
{
"WorkName": "本圧着部P1、P2架台切り離し④(架台)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り切り離し出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "TCP供給部切り離し",
"Words": [
"連結ボルト取付け",
"連結ボルト取付け",
"本体内で固定する"
],
"WorkItems": [
"1. 連結ボルトを外し連結を外す",
"2. TCPを切り離す",
"3. 連結ケーブル/配管を外す",
"4. 連結ケーブル/配管を本体へ格納する"
],
"WorkPoints": [
"1、TCP供給部のアジャストボルトにスライディングペーパーを敷く2、50㎜以上離す(規正ピンをかわすまで)3、アジャストボルトを下げ、ローラを接地させる4、TCP供給部を十分に離す5、外した連結ボルトを本体へ取付ける",
"1、ケーブル、配管を外す ※光ケーブルを損傷させないように注意すること2、ケーブル/配管の先端をエアマットで保護する",
"1、本体へ格納し、固定する"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "レンチ",
"Size": "8㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "スパナ",
"Size": "46㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "+ドライバー",
"Size": "No.2",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26",
"使用治工具No.28",
"使用治工具No.27"
]
} | [
{
"WorkName": "TCP供給部切り離し",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り切り離し出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定①(上流仮置き部/下流仮置き部)",
"Words": [
"上流仮置き部",
"下流仮置き部",
"①上流仮置き部:【USZ軸】②パネル規正",
"③下流仮置き部:【DSZ軸】"
],
"WorkItems": [
"1. 付属の固定金具で各軸を固定する"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "レンチ",
"Size": "2.5㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "レンチ",
"Size": "3㎜",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26,27"
]
} | [
{
"WorkName": "軸固定①(上流仮置き部/下流仮置き部)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定②(ACF貼付部、ACF可動部)",
"Words": [
"ACF貼付け駆動部",
"①ACF 貼付部【AHLX軸、AHRX軸】",
"②テンションローラおもり",
"ACFヘッド部"
],
"WorkItems": [
"1. 付属の固定金具で各軸を固定する"
],
"WorkPoints": [
"AL",
"AR"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "レンチ",
"Size": "2.5㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "レンチ",
"Size": "3㎜",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26,27"
]
} | [
{
"WorkName": "軸固定②(ACF貼付部、ACF可動部)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定③(仮圧着ユニット部)",
"Words": [
"③仮圧着本認識カメラ部",
"④仮圧着移載部",
"①仮圧着ヘッド部:【MH軸】",
"④仮圧着移載部:【MTY軸:TTX軸】",
"②選択OP)仮圧着部品認識カメラ部:【MTC】",
"IC仕様",
"TCP仕様",
"③仮圧着本認識カメラ部:【MCY軸】",
"①仮圧着ヘッド部",
"②仮圧着部品認識カメラ部"
],
"WorkItems": [
"1. 付属の固定金具で各軸を固定する"
],
"WorkPoints": [
"MH軸",
"MTC",
"※上から固定",
"※下から固定",
"TTX軸",
"MTY軸",
"MCY軸"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "レンチ",
"Size": "2.5㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "レンチ",
"Size": "3㎜",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26,27"
]
} | [
{
"WorkName": "軸固定③(仮圧着ユニット部)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定④(本圧着部)",
"Words": [
"①本圧着ヘッド部",
"①本圧着ヘッド部:【P1H軸、P2H軸】"
],
"WorkItems": [
"1. 付属の固定金具で各軸を固定する"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "レンチ",
"Size": "3㎜",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26"
]
} | [
{
"WorkName": "軸固定④(本圧着部)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定⑤(ACF/仮圧着/本圧着ユニットテーブル部)",
"Words": [
"①テーブル部",
"①ACF、仮圧着、本圧着 テーブル部:【X軸、Y軸】"
],
"WorkItems": [
"1. 付属の固定金具で各軸を固定する"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "レンチ",
"Size": "3㎜",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26"
]
} | [
{
"WorkName": "軸固定⑤(ACF/仮圧着/本圧着ユニットテーブル部)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定⑥(パネル搬送部)",
"Words": [
"①AMパネル搬送部:【SUX軸、SMX軸】②P1パネル搬送部:【SP1X軸】※P2有の場合",
"AM設備",
"P1設備",
"P2設備",
"①SUX軸",
"搬送2",
"搬送3",
"搬送4",
"搬送5",
"①SMX軸",
"②SP1X軸",
"③SP2X軸",
"③DSX軸",
"③P2パネル搬送部:【SP2X軸、DSX軸】",
"上面図",
"上面図"
],
"WorkItems": [
"1. 付属の固定金具で各軸を固定する",
"正流れ",
"逆流れ",
"正・逆流れ",
"■ ②SP1X軸 ③SP2X軸 リニアカバー取付け"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "レンチ",
"Size": "3㎜",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26"
]
} | [
{
"WorkName": "軸固定⑥(パネル搬送部)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定⑦(TCP供給部)",
"Words": [
"①TCP供給部後面:【TS軸】",
"TCP供給部",
"②TCP供給部後部後面:【THY軸】",
"③TCP供給部R側:【TPH(R):金型ホルダ】",
"⑤TCP供給部L側:【TPH(L):金型ホルダ】",
"⑤TCP供給部L側:【送りローラー】",
"④TCP供給部R側:【送りローラー】",
"【TDR:段差ローラー】",
"【TDR:段差ローラー】"
],
"WorkItems": [
"1. 付属の固定金具で各軸を固定する"
],
"WorkPoints": [
"TPH(R)",
"TS軸",
"後面",
"L側",
"R側",
"THY軸",
"TPH(L)",
"TDR",
"TDR",
"エアーマット・インシュロッグで固定",
"エアーマット・インシュロックで固定"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "レンチ",
"Size": "3㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "レンチ",
"Size": "4㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "エアーマット",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.29",
"ToolName": "インシュロック",
"Size": "200㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.30",
"ToolName": "ニッパー",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.31",
"ToolName": "ハサミ",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26,27,28,29,30,31"
]
} | [
{
"WorkName": "軸固定⑦(TCP供給部)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定⑧(IC供給部)",
"Words": [
"①ICトレイステージ部:【ITV軸】",
"ICトレイステージ部",
"②ICトレイステージXY軸部:【ITX軸】",
"上面図",
"上面図",
"ICトレイステージXY軸部"
],
"WorkItems": [
"1. 付属の固定金具で各軸を固定する"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "レンチ",
"Size": "3㎜",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26"
]
} | [
{
"WorkName": "軸固定⑧(IC供給部)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定⑨(FAパソコン固定)",
"Words": [
"FAパソコン",
"①FAパソコン固定部",
"※AM正流れ"
],
"WorkItems": [
"1. 付属の固定金具で各軸を固定する"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "レンチ",
"Size": "3㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "プラスドライバー",
"Size": "2",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26,27"
]
} | [
{
"WorkName": "軸固定⑨(FAパソコン固定)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "メンテナンスカバー取付確認",
"Words": [
"1.設備メンテナンスカバー取付確認",
"2.TCP供給部メンテナンスカバー取付確認・・・3ヶ所",
"TCP供給部左側(打抜き下部)",
"TCP供給部右側(本体連結部)",
"P1、P2設備後面(本圧保護シート排出部)",
"TCP供給部右側(打抜き下部)"
],
"WorkItems": [],
"WorkPoints": [
"供給部単体立上時実施(個別仕様)"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "メンテナンスカバー取付確認",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定⑩(テープ固定/エアーマット固定)",
"Words": [
"AM",
"P1(P2)",
"①仮圧着部:【本認識カメラ】",
"③パトライト部",
"パトライト部",
"仮圧着部",
"本圧着部",
"ファン部",
"パトライト部",
"ファン部",
"④ファン部",
"②本圧着部:【シートカセット、カメラ】"
],
"WorkItems": [
"1. 付属の固定金具で各軸を固定する"
],
"WorkPoints": [
"※エアーマットにて本認識カメラを保護する",
"※パトライトをエアーマットにて包んで本体の 天井にテープにて固定する",
"すべてのファンをエアマットで塞ぐ※供給部含む",
"※シートカセットをインシュロックで固定し、 ノブをテープで固定する",
"※エアーマットにてカメラを保護する"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "テープ",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "エアーマット",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "インシュロック",
"Size": "200㎜",
"Other": "-"
},
{
"JiguNo": "使用治工具No.29",
"ToolName": "ニッパー",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.30",
"ToolName": "ハサミ",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26,27,28,29,30"
]
} | [
{
"WorkName": "軸固定⑩(テープ固定/エアーマット固定)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定⑪(HDD固定)",
"Words": [
"AM",
"①HDD部"
],
"WorkItems": [
"1. 付属の固定金具で各軸を固定する"
],
"WorkPoints": [
"※HDDケースをFAパソコン横にPPバンド で固定する"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "テープ",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "エアーマット",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "ハサミ",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.29",
"ToolName": "PPバンド",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26.27.28.29"
]
} | [
{
"WorkName": "軸固定⑪(HDD固定)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定⑫(前面、背面カバー、モニター、パトライト固定・保護)",
"Words": [
"AM",
"P1(P2)",
"①モニタ",
"①モニタ",
"②AM前面カバー",
"③P前面カバー",
"①AM、Pモニター",
"②AM前面カバー",
"③P前面カバー",
"⑤上:IC供給カバー 下:メンテナンスカバー",
"④Mメンテナンスカバー",
"AM",
"④Mメンテナンスカバー",
"⑤上:IC供給カバー 下:メンテナンスカバー"
],
"WorkItems": [
"1. 設備を保護する"
],
"WorkPoints": [
"※タッチパネルをエアーマットで保護しテープで固定",
"各カバーをテープにてドアを固定する",
"各カバーをテープにてドアを固定する",
"各カバーをテープにてドアを固定する",
"各カバーをテープにてドアを固定する"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "テープ",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "エアーマット",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "ハサミ",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26,27,28"
]
} | [
{
"WorkName": "軸固定⑫(前面、背面カバー、モニター、パトライト固定・保護)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定⑬(本体部背面、側面部外装固定・保護)AM",
"Words": [
"④上流側面開口部",
"①本体背面開口部(TCP供給連結部)",
"③主電源、空圧部",
"⑤上流連結部",
"②ファン",
"⑥下流側開口部",
"⑦下流開口部(連結ケーブル)"
],
"WorkItems": [
"1. 設備を保護する"
],
"WorkPoints": [
"※下記7か所をエアーマットで保護しテープで固定①本体背面開口部(TCP供給連結部)②ファン③主電源、空圧部④上流側面開口部⑤上流連結部⑥下流側開口部⑦下流開口部(連結ケーブル)"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "テープ",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "エアーマット",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "ハサミ",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26,27,28"
]
} | [
{
"WorkName": "軸固定⑬(本体部背面、側面部外装固定・保護)AM",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定⑭(本体部背面、側面部外装固定・保護)P1",
"Words": [
"①上流側面開口部",
"⑤下流側面開口部",
"③パネル搬送部",
"④上流開口部(連結ケーブル)",
"⑦下流開口部(連結ケーブル)",
"②ファン",
"⑥下流側面開口部(架台)"
],
"WorkItems": [
"1. 設備を保護する"
],
"WorkPoints": [
"※下記7か所をエアーマットで保護しテープで固定①上流側面開口部②ファン③パネル搬送部④上流開口部(連結ケーブル)⑤下流側面開口部⑥下流側面開口部(架台)⑦下流開口部(連結ケーブル)"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "テープ",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "エアーマット",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "ハサミ",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26,27,28"
]
} | [
{
"WorkName": "軸固定⑭(本体部背面、側面部外装固定・保護)P1",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定⑮(本体部背面、側面部外装固定・保護)P2",
"Words": [
"②ファン",
"④上流開口部(連結ケーブル)",
"①上流側面開口部",
"③パネル搬送部",
"⑤下流側面開口部",
"⑥下流連結部"
],
"WorkItems": [
"1. 設備を保護する"
],
"WorkPoints": [
"※下記6か所をエアーマットで保護しテープで固定①上流側面開口部②ファン③パネル搬送部④上流開口部(連結ケーブル)⑤下流側面開口部⑥下流連結部"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "テープ",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "エアーマット",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "ハサミ",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26,27,28"
]
} | [
{
"WorkName": "軸固定⑮(本体部背面、側面部外装固定・保護)P2",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "軸固定⑯(TCP供給部外装固定・保護)",
"Words": [
"背面扉",
"①本体連結部 開口部",
"②操作盤部R側",
"④非常停止、部品交換SW",
"⑤ファン",
"⑥操作盤部R側",
"L側扉テープ固定",
"R側扉テープ固定",
"L側扉テープ固定",
"アイボルト",
"③開口部(オプション時)",
"R側扉テープ固定",
"アイボルト"
],
"WorkItems": [
"1. 設備を保護する",
"2.開閉扉を固定する",
"3.アイボルト取付け"
],
"WorkPoints": [
"LR扉、背面扉をテープで固定",
"※下記6か所をエアーマットで保護しテープで固定①本体連結部 開口部②操作盤部R側③開口部(オプション時)④非常停止、部品交換SW⑤ファン⑥操作盤部R側",
"※カバーからの飛び出し部分をエアーマットで保護し固定",
"運送会社の指示がある場合、アイボルトを取付ける。"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "テープ",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "エアーマット",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "ハサミ",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26,27,28"
]
} | [
{
"WorkName": "軸固定⑯(TCP供給部外装固定・保護)",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "押せ、押すなシール貼付け①(AM本体部)",
"Words": [
"②設備正面右側",
"④設備後面左側",
"Mカバー右",
"Mカバー左",
"タッチパネル",
"右側面",
"上流仮置きカバー",
"Aカバー左",
"Aカバー右",
"左側面",
"上流仮置きカバー",
"Aカバー後",
"Aメンテナンスカバー",
"Mカバー後",
"M開口部",
"IC供給カバー",
"ICメンテナンスカバー",
"ICカバー後",
"①設備正面右側",
"③設備後面右側"
],
"WorkItems": [
"1. 梱包配善BOX内:押せ・押すなシールの確認",
"2. 設備シール貼付け【押せシール】",
"3. 設備シール貼付け【押すなシール】"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "押せ、押すなシール貼付け①(AM本体部)",
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指定の位置に指示通り貼付け出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "押せ、押すなシール貼付け②(P1本体部)",
"Words": [
"①設備正面左側",
"②設備正面右側",
"④設備後面左側",
"③設備後面右側",
"タッチパネル",
"右側面",
"P1カバー左",
"P1カバー右",
"P1メンテナンスカバー",
"P1カバー後",
"パネル搬送部",
"左側面"
],
"WorkItems": [
"1. 梱包配善BOX内:押せ・押すなシールの確認",
"2. 設備シール貼付け【押せシール】",
"3. 設備シール貼付け【押すなシール】"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "押せ、押すなシール貼付け②(P1本体部)",
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指定の位置に指示通り貼付け出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "押せ、押すなシール貼付け③(P2本体部)",
"Words": [
"①設備正面左側",
"②設備正面右側",
"④設備後面左側",
"③設備後面右側",
"右側面",
"P2カバー左",
"P2カバー右",
"下流仮置きカバー前",
"左側面",
"下流仮置きカバー後",
"P2メンテナンスカバー",
"P2カバー後",
"パネル搬送部"
],
"WorkItems": [
"1. 梱包配善BOX内:押せ・押すなシールの確認",
"2. 設備シール貼付け【押せシール】",
"3. 設備シール貼付け【押すなシール】"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "押せ、押すなシール貼付け③(P2本体部)",
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指定の位置に指示通り貼付け出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "押せ、押すなシール貼付け④(TCP供給部)",
"Words": [
"①TCP供給部後面側",
"①TCP供給部後面側",
"②本体部連結側"
],
"WorkItems": [
"3. 設備シール貼付け【押すなシール】",
"1. 梱包配善BOX内:押せ・押すなシールの確認",
"2. 設備シール貼付け【押せシール】"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [],
"Jigus": []
} | [
{
"WorkName": "押せ、押すなシール貼付け④(TCP供給部)",
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指定の位置に指示通り貼付け出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "カバーボルト固定実施①(増締め確認/ガムテープ固定)",
"Words": [
"P1",
"AM",
"P2",
"(TCP供給)"
],
"WorkItems": [
"2. カバーボルトトルク確認後、ガムテープにて落下防止を実施",
"1. カバーボルトの増締め確認をする。 AM(TCP供給)、P1、P2"
],
"WorkPoints": [
"カバーすべて増し締めのこと",
"設備正面/側面/背面のすべてのカバー",
"設備正面/側面/背面のすべてのカバー"
],
"Tolks": [
"締付トルク 160cN・m"
],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "トルクドライバー",
"Size": "No.2",
"Other": "160cN・m"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "テープ",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26",
"使用治工具No.27"
]
} | [
{
"WorkName": "カバーボルト固定実施①(増締め確認/ガムテープ固定)",
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolName": "トルクドライバー",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "160cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "安全パンフレット・据付結果連絡書・シリアル管理票貼付",
"Words": [
"シリアル管理票",
"据付結果連絡書",
"安全パンフレット",
"出荷明細基本ベースは上記指定フォルダ内を参照",
"チェック項目内容の資料を準備",
"レポート表紙",
"<AM>"
],
"WorkItems": [
"4. レポート原紙を付属品ダンボールに格納し封印",
"3. レポート完成後、一式をPDFに変換し出荷フォルダ内のレポートフォルダに格納する",
"2. 2)レポート:出荷明細を作成する",
"1. シリアル管理票、安全パンフレットと据付結果連絡書を設備に貼付ける"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "テープ",
"Size": "-",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26"
]
} | [
{
"WorkName": "安全パンフレット・据付結果連絡書・シリアル管理票貼付",
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolName": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "銘板確認・RoHSシール貼付",
"Words": [
"TCP供給部背面",
"正流れ",
"逆流れ",
"本圧着部背面",
"※正流れ",
"※逆流れ",
"※TCP供給ありの場合のみ",
"※P2ありの場合のみ"
],
"WorkItems": [
"■1. 銘板,RoHSシールの貼付確認をする"
],
"WorkPoints": [],
"Tolks": [],
"InspectionItems": [
"検査表①:銘板確認,RoHSシール貼付け"
],
"InspectionNos": [
"WWYJ-5500-004"
],
"WorkTypes": [
"■安全作業",
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "スケール",
"Size": "150",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26"
]
} | [
{
"WorkName": "銘板確認・RoHSシール貼付",
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolName": "スケール",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "指定の位置に指示通り貼付け出来ている事",
"Method": "スケール",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null | |
{
"UnitName": "検査梱包(本体検査)(001-055)",
"WorkName": "本体ラッピング①(AM)",
"Words": [
"梱包袋",
"ラップフィルム",
"50㎜",
"50㎜",
"リサイクルシール",
"A",
"B",
"明細用袋"
],
"WorkItems": [
"1. 上面より梱包袋を被せる",
"2. 下部にラッピングを行う",
"4. リサイクルシールを貼付ける",
"3. 明細用袋貼付"
],
"WorkPoints": [
"※ガムテープの固定方法"
],
"Tolks": [],
"InspectionItems": [],
"InspectionNos": [],
"WorkTypes": [
"■安全作業"
],
"ToolPartsModels": [
{
"JiguNo": "使用治工具No.26",
"ToolName": "梱包袋",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.27",
"ToolName": "ラップフィルム",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.28",
"ToolName": "明細用袋",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.29",
"ToolName": "テープ",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.30",
"ToolName": "リサイクルシール",
"Size": "-",
"Other": "-"
},
{
"JiguNo": "使用治工具No.31",
"ToolName": "スケール",
"Size": "150㎜",
"Other": "-"
}
],
"Jigus": [
"使用治工具No.26",
"使用治工具No.27",
"使用治工具No.28,29",
"使用治工具No.30,31"
]
} | [
{
"WorkName": "本体ラッピング①(AM)",
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolName": "スケール",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "指定の位置に指示通り貼付け出来ている事",
"Method": "スケール",
"RecordMethod": "-",
"Others": "-",
"ProcessNames": [
"安全工程"
]
}
] | information_extraction | 0 | null |