Dataset Preview
Duplicate
The full dataset viewer is not available (click to read why). Only showing a preview of the rows.
The dataset generation failed
Error code:   DatasetGenerationError
Exception:    ArrowInvalid
Message:      Float value 3.143000 was truncated converting to int64
Traceback:    Traceback (most recent call last):
                File "/usr/local/lib/python3.14/site-packages/datasets/builder.py", line 1856, in _prepare_split_single
                  writer.write_table(table)
                  ~~~~~~~~~~~~~~~~~~^^^^^^^
                File "/usr/local/lib/python3.14/site-packages/datasets/arrow_writer.py", line 811, in write_table
                  self._write_table(pa_table, writer_batch_size=writer_batch_size)
                  ~~~~~~~~~~~~~~~~~^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
                File "/usr/local/lib/python3.14/site-packages/datasets/arrow_writer.py", line 822, in _write_table
                  pa_table = table_cast(pa_table, self._schema)
                File "/usr/local/lib/python3.14/site-packages/datasets/table.py", line 2394, in table_cast
                  return cast_table_to_schema(table, schema)
                File "/usr/local/lib/python3.14/site-packages/datasets/table.py", line 2328, in cast_table_to_schema
                  cast_array_to_feature(
                  ~~~~~~~~~~~~~~~~~~~~~^
                      table[name] if name in table_column_names else pa.array([None] * len(table), type=schema.field(name).type),
                      ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
                      feature,
                      ^^^^^^^^
                  )
                  ^
                File "/usr/local/lib/python3.14/site-packages/datasets/table.py", line 1870, in wrapper
                  return pa.chunked_array([func(chunk, *args, **kwargs) for chunk in array.chunks])
                                           ~~~~^^^^^^^^^^^^^^^^^^^^^^^^
                File "/usr/local/lib/python3.14/site-packages/datasets/table.py", line 2164, in cast_array_to_feature
                  return array_cast(
                      array,
                  ...<2 lines>...
                      allow_decimal_to_str=allow_decimal_to_str,
                  )
                File "/usr/local/lib/python3.14/site-packages/datasets/table.py", line 1872, in wrapper
                  return func(array, *args, **kwargs)
                File "/usr/local/lib/python3.14/site-packages/datasets/table.py", line 2024, in array_cast
                  return array.cast(pa_type)
                         ~~~~~~~~~~^^^^^^^^^
                File "pyarrow/array.pxi", line 1217, in pyarrow.lib.Array.cast
                File "/usr/local/lib/python3.14/site-packages/pyarrow/compute.py", line 415, in cast
                  return call_function("cast", [arr], options, memory_pool)
                File "pyarrow/_compute.pyx", line 610, in pyarrow._compute.call_function
                File "pyarrow/_compute.pyx", line 405, in pyarrow._compute.Function.call
                  result = GetResultValue(
                File "pyarrow/error.pxi", line 155, in pyarrow.lib.pyarrow_internal_check_status
                File "pyarrow/error.pxi", line 92, in pyarrow.lib.check_status
                  raise convert_status(status)
              pyarrow.lib.ArrowInvalid: Float value 3.143000 was truncated converting to int64
              
              The above exception was the direct cause of the following exception:
              
              Traceback (most recent call last):
                File "/src/services/worker/src/worker/job_runners/config/parquet_and_info.py", line 1379, in compute_config_parquet_and_info_response
                  parquet_operations, partial, estimated_dataset_info = stream_convert_to_parquet(
                                                                        ~~~~~~~~~~~~~~~~~~~~~~~~~^
                      builder, max_dataset_size_bytes=max_dataset_size_bytes
                      ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
                  )
                  ^
                File "/src/services/worker/src/worker/job_runners/config/parquet_and_info.py", line 956, in stream_convert_to_parquet
                  builder._prepare_split(split_generator=splits_generators[split], file_format="parquet")
                  ~~~~~~~~~~~~~~~~~~~~~~^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
                File "/usr/local/lib/python3.14/site-packages/datasets/builder.py", line 1702, in _prepare_split
                  for job_id, done, content in self._prepare_split_single(
                                               ~~~~~~~~~~~~~~~~~~~~~~~~~~^
                      gen_kwargs=gen_kwargs, job_id=job_id, **_prepare_split_args
                      ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
                  ):
                  ^
                File "/usr/local/lib/python3.14/site-packages/datasets/builder.py", line 1887, in _prepare_split_single
                  raise DatasetGenerationError("An error occurred while generating the dataset") from e
              datasets.exceptions.DatasetGenerationError: An error occurred while generating the dataset

Need help to make the dataset viewer work? Make sure to review how to configure the dataset viewer, and open a discussion for direct support.

ts
string
mac
string
source
string
temp_c
float64
rh_pct
float64
press_pa
null
battery
int64
rssi
int64
n
int64
2026-08-28T02:05:00Z
sensor-02
h5075
25.3
50.1
null
91
-53
2
2026-08-28T02:06:00Z
sensor-01
h5075
25.5
49.5
null
100
-57
2
2026-08-28T02:06:00Z
sensor-03
h5075
25.3
49.9
null
93
-50
2
2026-08-28T02:20:00Z
sensor-01
h5075
25.2
50.9
null
100
-59
4
2026-08-28T02:20:00Z
sensor-03
h5075
25.3
50.85
null
93
-61
8
2026-08-28T02:21:00Z
sensor-01
h5075
25.3
50.7
null
100
-52
6
2026-08-28T02:21:00Z
sensor-03
h5075
25.2
50.5
null
93
-60
6
2026-08-28T02:21:00Z
sensor-02
h5075
24.9
51.6
null
91
-56
8
2026-08-28T02:22:00Z
sensor-01
h5075
25.2
50.7
null
100
-57
12
2026-08-28T02:22:00Z
sensor-03
h5075
25.2
50.5
null
93
-58
4
2026-08-28T02:22:00Z
sensor-02
h5075
24.8
51.8
null
91
-63
6
2026-08-28T02:23:00Z
sensor-01
h5075
25.2
50.65
null
100
-53
8
2026-08-28T02:23:00Z
sensor-03
h5075
25.2
50.6
null
93
-58
6
2026-08-28T02:23:00Z
sensor-02
h5075
24.9
51.75
null
90
-54
8
2026-08-28T02:24:00Z
sensor-01
h5075
25.2
50.8
null
100
-45
2
2026-08-28T02:24:00Z
sensor-03
h5075
25.2
50.6
null
93
-59
8
2026-08-28T02:24:00Z
sensor-02
h5075
24.8
51.9
null
90
-54
10
2026-08-28T02:25:00Z
sensor-01
h5075
25.2
50.8
null
100
-68
5
2026-08-28T02:25:00Z
sensor-03
h5075
25.2
50.6
null
93
-53
3
2026-08-28T02:25:00Z
sensor-02
h5075
24.8
51.8
null
91
-53
8
2026-08-28T02:26:00Z
sensor-01
h5075
25.2
50.8
null
100
-61
6
2026-08-28T02:26:00Z
sensor-03
h5075
25.2
50.6
null
93
-53
10
2026-08-28T02:26:00Z
sensor-02
h5075
24.8
51.85
null
91
-53
4
2026-08-28T02:27:00Z
sensor-01
h5075
25.2
50.75
null
100
-54
8
2026-08-28T02:27:00Z
sensor-03
h5075
25.2
50.5
null
93
-57
2
2026-08-28T02:27:00Z
sensor-02
h5075
24.8
51.9
null
91
-52
10
2026-08-28T02:28:00Z
sensor-01
h5075
25.15
50.65
null
100
-60
4
2026-08-28T02:28:00Z
sensor-03
h5075
25.2
50.6
null
93
-53
10
2026-08-28T02:28:00Z
sensor-02
h5075
24.8
51.85
null
91
-53
8
2026-08-28T02:29:00Z
sensor-01
h5075
25.1
50.8
null
100
-63
7
2026-08-28T02:29:00Z
sensor-03
h5075
25.2
50.5
null
93
-55
10
2026-08-28T02:29:00Z
sensor-02
h5075
24.8
51.9
null
91
-55
4
2026-08-28T02:30:00Z
sensor-01
h5075
25.1
50.8
null
100
-60
6
2026-08-28T02:30:00Z
sensor-03
h5075
25.2
50.6
null
93
-53
4
2026-08-28T02:30:00Z
sensor-02
h5075
24.8
51.9
null
91
-55
6
2026-08-28T02:31:00Z
sensor-01
h5075
25.1
51.05
null
100
-60
12
2026-08-28T02:31:00Z
sensor-03
h5075
25.2
50.85
null
93
-56
4
2026-08-28T02:31:00Z
sensor-02
h5075
24.8
52.1
null
91
-54
12
2026-08-28T02:32:00Z
sensor-01
h5075
25.1
50.95
null
100
-55
8
2026-08-28T02:32:00Z
sensor-03
h5075
25.2
50.7
null
93
-56
12
2026-08-28T02:32:00Z
sensor-02
h5075
24.8
52.1
null
91
-54
6
2026-08-28T02:33:00Z
sensor-01
h5075
25.1
50.9
null
100
-57
4
2026-08-28T02:33:00Z
sensor-03
h5075
25.2
50.6
null
93
-56
2
2026-08-28T02:33:00Z
sensor-02
h5075
24.7
52.2
null
91
-53
6
2026-08-28T02:34:00Z
sensor-01
h5075
25.1
50.95
null
100
-55
8
2026-08-28T02:34:00Z
sensor-03
h5075
25.2
50.6
null
93
-53
6
2026-08-28T02:34:00Z
sensor-02
h5075
24.8
52.15
null
91
-57
4
2026-08-28T02:35:00Z
sensor-01
h5075
25.1
50.95
null
100
-62
4
2026-08-28T02:35:00Z
sensor-03
h5075
25.2
50.65
null
93
-57
4
2026-08-28T02:35:00Z
sensor-02
h5075
24.8
52.1
null
91
-55
2
2026-08-28T02:36:00Z
sensor-01
h5075
25.1
51
null
100
-54
6
2026-08-28T02:36:00Z
sensor-03
h5075
25.2
50.6
null
93
-55
6
2026-08-28T02:36:00Z
sensor-02
h5075
24.7
52.1
null
91
-53
7
2026-08-28T02:37:00Z
sensor-01
h5075
25.05
51
null
100
-59
8
2026-08-28T02:37:00Z
sensor-03
h5075
25.2
50.6
null
93
-51
3
2026-08-28T02:37:00Z
sensor-02
h5075
24.7
52.15
null
91
-53
4
2026-08-28T02:38:00Z
sensor-01
h5075
25.1
51
null
100
-53
6
2026-08-28T02:38:00Z
sensor-03
h5075
25.2
50.7
null
93
-53
8
2026-08-28T02:38:00Z
sensor-02
h5075
24.7
52.25
null
91
-55
4
2026-08-28T02:39:00Z
sensor-01
h5075
25
51.2
null
100
-65
8
2026-08-28T02:39:00Z
sensor-03
h5075
25.2
50.7
null
93
-52
6
2026-08-28T02:39:00Z
sensor-02
h5075
24.7
52.3
null
91
-54
10
2026-08-28T02:40:00Z
sensor-01
h5075
25
51.1
null
100
-60
3
2026-08-28T02:40:00Z
sensor-03
h5075
25.2
50.7
null
93
-54
8
2026-08-28T02:40:00Z
sensor-02
h5075
24.7
52.35
null
91
-59
4
2026-08-28T02:41:00Z
sensor-01
h5075
25
51.1
null
100
-56
10
2026-08-28T02:41:00Z
sensor-03
h5075
25.2
50.7
null
93
-54
4
2026-08-28T02:41:00Z
sensor-02
h5075
24.7
52.4
null
91
-52
12
2026-08-28T02:42:00Z
sensor-01
h5075
25
51.2
null
100
-55
4
2026-08-28T02:42:00Z
sensor-03
h5075
25.2
50.8
null
93
-54
10
2026-08-28T02:42:00Z
sensor-02
h5075
24.65
52.4
null
91
-52
4
2026-08-28T02:43:00Z
sensor-01
h5075
25
51.3
null
100
-57
4
2026-08-28T02:43:00Z
sensor-03
h5075
25.2
50.9
null
93
-51
8
2026-08-28T02:43:00Z
sensor-02
h5075
24.7
52.5
null
91
-57
6
2026-08-28T02:44:00Z
sensor-01
h5075
25
51.45
null
100
-57
8
2026-08-28T02:44:00Z
sensor-03
h5075
25.15
50.95
null
93
-47
4
2026-08-28T02:44:00Z
sensor-02
h5075
24.7
52.4
null
91
-52
4
2026-08-28T02:45:00Z
sensor-01
h5075
25
51.4
null
100
-58
8
2026-08-28T02:45:00Z
sensor-03
h5075
25.1
50.9
null
93
-50
6
2026-08-28T02:45:00Z
sensor-02
h5075
24.65
52.5
null
91
-58
8
2026-08-28T02:46:00Z
sensor-01
h5075
25
51.4
null
100
-58
10
2026-08-28T02:46:00Z
sensor-03
h5075
25.1
51
null
93
-51
10
2026-08-28T02:46:00Z
sensor-02
h5075
24.6
52.5
null
91
-53
14
2026-08-28T02:47:00Z
sensor-01
h5075
25
51.5
null
100
-53
3
2026-08-28T02:47:00Z
sensor-03
h5075
25.1
51
null
93
-49
6
2026-08-28T02:47:00Z
sensor-02
h5075
24.6
52.55
null
91
-55
8
2026-08-28T02:48:00Z
sensor-01
h5075
24.9
51.55
null
100
-54
12
2026-08-28T02:48:00Z
sensor-03
h5075
25.1
51.1
null
93
-55
6
2026-08-28T02:48:00Z
sensor-02
h5075
24.6
52.5
null
91
-53
8
2026-08-28T02:49:00Z
sensor-01
h5075
24.9
51.65
null
100
-54
12
2026-08-28T02:49:00Z
sensor-03
h5075
25
51.1
null
93
-127
1
2026-08-28T02:49:00Z
sensor-02
h5075
24.6
52.7
null
91
-49
6
2026-08-28T02:50:00Z
sensor-01
h5075
24.9
51.7
null
100
-61
10
2026-08-28T02:50:00Z
sensor-03
h5075
25
51.3
null
93
-52
8
2026-08-28T02:50:00Z
sensor-02
h5075
24.6
52.7
null
91
-44
8
2026-08-28T02:51:00Z
sensor-01
h5075
24.9
51.75
null
100
-50
8
2026-08-28T02:51:00Z
sensor-03
h5075
25
51.25
null
93
-57
4
2026-08-28T02:51:00Z
sensor-02
h5075
24.6
52.7
null
91
-47
12
2026-08-28T02:52:00Z
sensor-01
h5075
24.9
51.9
null
100
-58
2
2026-08-28T02:52:00Z
sensor-03
h5075
25
51.45
null
93
-50
4
End of preview.

Homeostat telemetry

1 Hz thermal / fan / load telemetry from a Google Coral Dev Board (NXP i.MX 8MQ + Edge TPU, binary GPIO fan, in an enclosure) whose accelerator is learning to manage its own body β€” starting with the fan/thermal policy. The project's code, experiment reports and regime log live at https://github.com/bshepp/homeostat (private at the time of writing; this card is meant to be sufficient on its own).

Layout

  • vultureman/ β€” the board. All files rotate on UTC days and carry a header row.
    • tlm-YYYYMMDD.csv β€” 1 Hz state, from 2026-08-03. Columns: ts (ISO-8601 UTC), uptime_s, cpu_temp_mC (1 degC granularity), tpu_temp_mC, fan (0/1), load0..load3 (% busy per core), cpu_khz, apex_open. From 2026-09-21T19:25:08Z six columns are appended: tpu_owned (0/1, the TPU's own ownership flag), tpu_irq_delta (TPU interrupts/s β€” inferring vs. merely held), trip_mC and hyst_mC (the live fan trip and hysteresis), boot_id, ntp_synced. An empty field means that read failed that second. A file renamed -v1 holds the rows written under the older header on the changeover day.
    • sessions.csv (sessions-v1.csv before the changeover) β€” ground-truth log of the induced CPU load sessions (type, cores, start/end, status).
    • tpuex-YYYYMMDD.csv β€” from 2026-09-21: the Edge TPU exerciser's intent log (released / held / burst, schedule block ids). It followed a seeded, pre-registered schedule and was the only TPU user until 2026-10-31.
    • ble-YYYYMMDD.csv β€” from 2026-09-21: ambient sensors heard on the board's own Bluetooth radio, 60 s medians. Columns: ts, mac (pseudonym), source, temp_c, rh_pct, press_pa, battery, rssi, n.
    • shadow-YYYYMMDD.csv (2026-09-06 β†’ 2026-09-14) and policy-YYYYMMDD.csv (from 2026-10-31) β€” a learned fan policy running on the Edge TPU: ts, would_be (the fan state it would choose), score_q (int8 output), actual_fan, agree, latency_ms, and from 2026-11-26T03:02Z mode (shadow or control), cmd (the fan state it commanded) and override (1 while a non-learned rule holds the fan on above 65 degC). policy-inputs-YYYYMMDD.csv holds the features it saw. A -v1 file is the part of a day written before a column was added. The policy is read-only wherever mode is shadow or absent, and the fan is then the kernel governor's. It commands the fan only in rows marked control. Those begin on 2026-11-26: a ten-minute fail-safe test at 03:02Z, then a first hold of about a day from 03:27Z. Later holds are not listed here; trust the column.
    • supervisor-YYYYMMDD.csv β€” from 2026-11-26: the event log of the non-learned supervisor that returns the fan to the kernel governor when something is wrong: ts, event (start, stop, heartbeat, revert, stock-violation), reason, t_cpu_mC, trip_mC, hyst_mC.
  • ambient/ β€” amb-YYYYMMDD.csv: the same sensors and columns as ble-*, heard by a second receiver elsewhere in the room.
  • archives/ β€” frozen, SHA256-manifested dataset versions cited by the system-identification reports (immutable).

Sensor MACs are replaced by stable pseudonyms (sensor-01, ...); one physical sensor keeps one pseudonym across ble-*, amb-* and the archives.

Things to know before using the data

  • Fan regimes. Stock kernel governor (fan on at 65 degC, 10 degC hysteresis) until 2026-08-12T03:56Z, again 2026-09-13T11:58Z β†’ 2026-09-21T19:25Z, and again from 2026-11-20T06:34Z; otherwise an excitation regime with the trip lowered to 57 degC. Two short test windows contain hand-commanded fan switching: 2026-11-20T06:34Z β†’ 07:03Z and 2026-11-26T03:00Z β†’ 03:13Z. The second also has a reboot and four emulated cpu_temp_mC samples of 66000 (03:09:16Z β†’ 03:09:19Z) that are not real temperatures. While the policy holds the fan it does so by moving the same trip: trip_mC reads 20000 (fan commanded on) or 65000 with hyst_mC 0 (commanded off; the kernel still turns the fan on at 65 degC). From 2026-09-21T19:25:08Z the trip is logged per row (trip_mC, hyst_mC) β€” trust the columns over this summary. The governor releases the fan only once the die is below trip βˆ’ hysteresis.
  • Obstructed airflow, 2026-09-02T06:00Z β†’ 2026-09-24T06:25Z. An ambient sensor (sensor-04) sat inside the enclosure against the fan and heatsink for 22 days, costing about 1.8x fan duty for the same die temperature, and it shifted over time. Thermal data from that window describes a different plant; sensor-04's readings in it are enclosure-interior, not room, temperatures.
  • Who holds the Edge TPU is a thermal input. A shadow daemon held it 2026-09-06T13:57Z β†’ 2026-09-14T06:24Z; the exerciser drove it on schedule from 2026-09-21; the policy daemon has held it since 2026-10-31T03:30:18Z, apart from a few seconds at each restart on 2026-11-26 (03:01Z β†’ 03:13Z). Before 2026-09-21 use the dates here; after it, use tpu_owned and tpu_irq_delta.
  • Clean system-identification window: 2026-09-25 β†’ 2026-10-12 (18 days: unobstructed, driven TPU, on-board ambient). The plant model the project froze was fitted and cross-validated on these days.
  • Die temperature has 1 degC resolution; the fan is on/off only. The board has no power telemetry.

Updates

Updated daily (the current day's files grow; closed UTC days never change).

Provenance & license

One person's bench instrument, collected with Claude as co-author. CC0 β€” use it for anything; attribution appreciated but not required.

Downloads last month
1,085