Dataset Viewer
Auto-converted to Parquet Duplicate
pwsid
string
collection_date
string
sample_id
string
pws_size
string
facility_water_type
string
state
string
epa_region
int64
prior_ucmr3_pfoa_pfos_detect
float64
prior_ucmr3_max_pfoa_pfos
float64
pfas_tested_before
string
pfas_treatment_before
string
potential_pfas_sources
string
potential_source_types
string
treatment_information
string
collection_year
int64
any_pfoa_pfos
int64
AR0000027
2023-01-03
100047P
S
SW
AR
6
null
null
NO
null
YES
AO;CW;MF;PS;UT
CON;CWL;SSF
2,023
0
AZ0407025
2023-01-03
2022100479
L
SW
AZ
9
0
0.04
YES
NMT
YES
PS
BIO;CON;PSD
2,023
0
CO0134150
2023-01-03
COLLEGEMESAWATERTREATMENT
L
SW
CO
8
0
0.04
YES
NMT
NO
null
CON;CWL;PSD
2,023
0
FL5364048
2023-01-03
810-49436-1
L
GW
FL
4
0
0.04
YES
NMT
NO
null
CWL;SFN;SSF
2,023
0
NY5110526
2023-01-03
200913463
L
GW
NY
2
1
0.53
YES
NMT
NO
null
NTU
2,023
0
WI2410563
2023-01-03
CB00061-01
L
SW
WI
5
0
0.04
DK
null
NO
null
NTU
2,023
0
WI4050468
2023-01-03
EP001
L
MX
WI
5
0
0.04
NO
null
NO
null
NTU
2,023
0
AR0000144
2023-01-04
100049P
S
SW
AR
6
null
null
YES
NMT
YES
CW;FP;MF;OG;PS;UT;WM
BIO;CON;CWL
2,023
0
AR0000193
2023-01-04
100050P
S
SW
AR
6
null
null
NO
null
YES
AO;CW;PS
CON;CWL;MFL;SSF
2,023
0
AR0000195
2023-01-04
O204933-533
L
SW
AR
6
0
0.04
YES
NMT
YES
AO;CW;OG;PC;UT
CON
2,023
0
AR0000488
2023-01-04
100053P
S
SW
AR
6
null
null
NO
null
YES
PC
CON;CWL;PAC;POB
2,023
0
AR0000504
2023-01-04
100054P
S
SW
AR
6
null
null
NO
null
YES
CW;UT
CON
2,023
0
AR0000725
2023-01-04
O204819-533
L
SW
AR
6
null
null
YES
NMT
YES
AO;CW;OG;PC;UT
CON
2,023
0
IA7717032
2023-01-04
100203P
S
SW
IA
7
null
null
NO
null
NO
null
CON;CWL;IEX;PAC;PSD;RBF;SFN
2,023
0
MD0220004
2023-01-04
GA00691-01
L
GW
MD
3
0
0.04
YES
NMT
YES
CW;MF;PS
CWA
2,023
1
MI0000130
2023-01-04
35770339001SE1
L
SW
MI
5
0
0.04
YES
NMT
NO
null
CON
2,023
0
MN1400013
2023-01-04
100343P
S
GW
MN
5
null
null
NO
null
DK
null
CON;OTH
2,023
0
VT0005016
2023-01-04
CB00124-01
L
SW
VT
1
0
0.04
YES
NMT
YES
MF
CON
2,023
0
KS2004503
2023-01-06
810-49474-1
L
SW
KS
7
0
0.04
YES
NMT
NO
null
CWL;PAC;PSD;SFN
2,023
0
AK2298103
2023-01-08
100002P
S
GW
AK
10
null
null
NO
null
NO
null
NTU
2,023
0
063503109
2023-01-09
100007P
S
GW
06
6
null
null
NO
null
NO
null
GWD
2,023
0
AL0000013
2023-01-09
100005P
S
SW
AL
4
null
null
DK
null
DK
null
NTU
2,023
1
AL0000702
2023-01-09
100036P
S
GW
AL
4
null
null
NO
null
NO
null
GWD
2,023
0
AZ0409029
2023-01-09
100058P
S
GW
AZ
9
null
null
YES
NMT
NO
null
CWL;GWD
2,023
0
AZ0413024
2023-01-09
100066P
S
GW
AZ
9
null
null
NO
null
DK
null
INF;OTH;POB
2,023
0
CA3310017
2023-01-09
100093P
S
GW
CA
9
null
null
NO
null
NO
null
GWD
2,023
0
CA3600152
2023-01-09
100108P
S
GW
CA
9
null
null
YES
NMT
NO
null
NTU
2,023
0
CO0119233
2023-01-09
100132P
S
SW
CO
8
null
null
YES
NMT
NO
null
CON;CWL;PSD
2,023
0
CO0144020
2023-01-09
100140P
S
GW
CO
8
null
null
DK
null
NO
null
GWD
2,023
0
FL3050834
2023-01-09
100153P
S
GW
FL
4
null
null
NO
null
NO
null
SFN
2,023
1
FL6080318
2023-01-09
100156P
S
GW
FL
4
null
null
NO
null
NO
null
MFL
2,023
0
FL6511311
2023-01-09
100161P
S
GW
FL
4
null
null
YES
NMT
NO
null
GWD
2,023
1
GA0570002
2023-01-09
35771527001SE1
L
SW
GA
4
0
0.04
YES
NMT
NO
null
CON;CWL;PSD
2,023
0
IA1970051
2023-01-09
100195P
S
GW
IA
7
null
null
NO
null
NO
null
NTU
2,023
0
IA6803010
2023-01-09
100202P
S
SW
IA
7
null
null
DK
null
DK
null
NTU
2,023
0
IA8400733
2023-01-09
100204P
S
GW
IA
7
null
null
NO
null
NO
null
CON;POB
2,023
0
IA8816089
2023-01-09
100205P
S
SW
IA
7
null
null
YES
NMT
NO
null
CON;CWL;GAC;MFL
2,023
0
IL0210500
2023-01-09
100210P
S
SW
IL
5
null
null
YES
NMT
NO
null
CON;CWL;PAC
2,023
0
IL0970840
2023-01-09
100215P
S
SW
IL
5
null
null
YES
NMT
NO
null
BIO;CON;CWL
2,023
0
IL1195210
2023-01-09
100221P
S
SW
IL
5
null
null
YES
NMT
DK
null
CON;CWL;PAC
2,023
0
IL1275050
2023-01-09
100846P
S
GW
IL
5
null
null
DK
null
NO
null
DKN
2,023
0
IL1630850
2023-01-09
100224P
S
SW
IL
5
null
null
NO
null
NO
null
NTU
2,023
0
IN5215009
2023-01-09
100236P
S
GW
IN
5
null
null
YES
NMT
NO
null
CON
2,023
0
IN5269001
2023-01-09
100241P
S
SW
IN
5
null
null
NO
null
NO
null
CON;CWL;GAC;PAC;POB
2,023
0
IN5279020
2023-01-09
61485801
L
GW
IN
5
0
0.04
YES
NMT
DK
null
CWA;DFL;POB
2,023
0
KY0300467
2023-01-09
100266P
S
GW
KY
4
null
null
YES
NMT
NO
null
NTU
2,023
1
KY0670466
2023-01-09
100271P
S
SW
KY
4
null
null
DK
null
DK
null
CON
2,023
0
KY0890304
2023-01-09
100274P
S
SW
KY
4
null
null
NO
null
DK
null
CON;CWL;PAC
2,023
0
KY0960499
2023-01-09
100275P
S
SW
KY
4
1
0.05853
NO
null
NO
null
NTU
2,023
0
LA1005035
2023-01-09
100282P
S
SW
LA
6
0
0.04
NO
null
NO
null
CON;CWL;SSF
2,023
0
LA1009004
2023-01-09
100283P
S
GW
LA
6
null
null
NO
null
NO
null
GWD
2,023
0
LA1079009
2023-01-09
100286P
S
GW
LA
6
null
null
DK
null
NO
null
ADS;OTH
2,023
0
LA1085059
2023-01-09
100288P
S
GW
LA
6
null
null
DK
null
DK
null
GAC
2,023
0
MA2343000
2023-01-09
100306P
S
SW
MA
1
null
null
YES
NMT
NO
null
DKN
2,023
0
MA3155000
2023-01-09
35771853001SE1
L
SW
MA
1
0
0.04
YES
NMT
NO
null
OTH;UTR
2,023
0
MA3308000
2023-01-09
35772143001SE1
L
SW
MA
1
0
0.04
YES
NMT
NO
null
OTH;UTR
2,023
0
MA3333000
2023-01-09
35771840001SE1
L
SW
MA
1
0
0.04
YES
NMT
NO
null
OTH;UTR
2,023
0
MA4036001
2023-01-09
100310P
S
GW
MA
1
null
null
YES
NMT
NO
null
NTU
2,023
0
MD0010005
2023-01-09
100318P
S
SW
MD
3
null
null
DK
null
NO
null
DKN
2,023
0
MD0100005
2023-01-09
100319P
S
SW
MD
3
null
null
YES
NMT
NO
null
CON;CWL;PAC
2,023
0
MN1560023
2023-01-09
100346P
S
GW
MN
5
null
null
YES
NMT
DK
null
OTH
2,023
0
MN1570003
2023-01-09
100348P
S
SW
MN
5
null
null
YES
NMT
DK
null
CON;OTH;PAC;SFN
2,023
0
MT0004790
2023-01-09
EP502
L
SW
MT
8
null
null
YES
NMT
NO
null
MFL
2,023
0
NC0144015
2023-01-09
100394P
S
SW
NC
4
null
null
NO
null
DK
null
CON;CWL;DFL;SSF
2,023
0
NC0197030
2023-01-09
100402P
S
SW
NC
4
null
null
NO
null
NO
null
CON
2,023
0
NC0230010
2023-01-09
100403P
S
SW
NC
4
null
null
YES
NMT
DK
null
CON;CWL;DFL;GAC;PAC
2,023
0
NC0459010
2023-01-09
100411P
S
GW
NC
4
null
null
NO
null
NO
null
GWD
2,023
0
NC0466110
2023-01-09
100416P
S
SW
NC
4
null
null
NO
null
NO
null
NTU
2,023
1
ND2700990
2023-01-09
100422P
S
SW
ND
8
null
null
YES
NMT
NO
null
CON;CWL;PAC;SFN
2,023
0
ND5301012
2023-01-09
61871801
L
SW
ND
8
0
0.04
YES
NMT
NO
null
CWL;PAC;SFN
2,023
0
NE3103904
2023-01-09
100424P
S
GW
NE
7
null
null
NO
null
NO
null
CWL;POB
2,023
0
NH1861010
2023-01-09
100436P
S
GW
NH
1
null
null
YES
NMT
NO
null
OTH
2,023
0
NJ1518005
2023-01-09
810-49670-1
L
GW
NJ
2
0
0.04
YES
NMT
YES
AO;FT;MB;WM
INF
2,023
0
NV0000168
2023-01-09
100469P
S
GW
NV
9
null
null
DK
null
NO
null
NTU
2,023
0
NV0002216
2023-01-09
100476P
S
GW
NV
9
null
null
DK
null
DK
null
GWD
2,023
0
OH4301511
2023-01-09
810-49614-1
L
SW
OH
5
0
0.04
DK
null
NO
null
CON
2,023
0
OK1010314
2023-01-09
100510P
S
SW
OK
6
null
null
DK
null
DK
null
CON
2,023
0
OK1011502
2023-01-09
100511P
S
SW
OK
6
null
null
NO
null
DK
null
CWL
2,023
0
OK1020418
2023-01-09
FA09017-01
L
SW
OK
6
0
0.04
YES
NMT
NO
null
CON;CWL;POB;PSD
2,023
0
OK3002603
2023-01-09
100522P
S
GW
OK
6
null
null
NO
null
NO
null
GWD
2,023
0
OK3005401
2023-01-09
100524P
S
SW
OK
6
null
null
NO
null
NO
null
NTU
2,023
0
OR4100549
2023-01-09
100529P
S
SW
OR
10
null
null
YES
NMT
DK
null
CON
2,023
0
OR4100550
2023-01-09
100530P
S
SW
OR
10
null
null
NO
null
NO
null
CWL;MFL
2,023
0
OR4100914
2023-01-09
100535P
S
GW
OR
10
null
null
NO
null
NO
null
GWD
2,023
0
SC0220004
2023-01-09
100586P
S
GW
SC
4
null
null
DK
null
NO
null
NTU
2,023
0
TN0000393
2023-01-09
35771528001SE1
L
SW
TN
4
0
0.04
NO
null
NO
null
CON;GAC
2,023
0
TX1010022
2023-01-09
100674P
S
SW
TX
6
null
null
NO
null
NO
null
GWD
2,023
0
TX1010210
2023-01-09
100676P
S
GW
TX
6
null
null
NO
null
NO
null
GWD
2,023
0
TX1010509
2023-01-09
100679P
S
SW
TX
6
null
null
NO
null
NO
null
CWL
2,023
0
TX1010897
2023-01-09
100684P
S
GW
TX
6
null
null
NO
null
NO
null
GWD
2,023
0
TX1011642
2023-01-09
100685P
S
GW
TX
6
null
null
NO
null
NO
null
GWD
2,023
0
TX1012392
2023-01-09
100688P
S
GW
TX
6
null
null
NO
null
NO
null
GWD
2,023
0
TX1013289
2023-01-09
100690P
S
GW
TX
6
null
null
NO
null
NO
null
GWD
2,023
0
TX1160015
2023-01-09
100698P
S
SW
TX
6
null
null
DK
null
NO
null
NTU
2,023
0
043740039
2023-01-10
100006P
S
SW
04
4
null
null
NO
null
NO
null
CON;CWL;POB
2,023
0
AL0000091
2023-01-10
100019P
S
GW
AL
4
null
null
NO
null
DK
null
GWD
2,023
0
AL0000125
2023-01-10
100024P
S
GW
AL
4
null
null
YES
NMT
NO
null
GWD
2,023
0
AL0000406
2023-01-10
100031P
S
GW
AL
4
null
null
YES
NMT
NO
null
CON;CWL;DFL;OTH;POB
2,023
0
AL0000594
2023-01-10
100032P
S
SW
AL
4
null
null
YES
NMT
NO
null
CWL;IEX;SSF
2,023
0
AL0001363
2023-01-10
100039P
S
GW
AL
4
null
null
NO
null
NO
null
GWD
2,023
0
End of preview. Expand in Data Studio

Dataset Factory · v-4a630108a6e75a6b

Dataset website · GitHub release · Hugging Face · Catalogue

Artifact: 1bf9c8af47a3cd62f65faa7f22efd3fd66ddc1f8ba0fbb0762b391cf6fb04a10

Will a public water system's first UCMR 5 entry-point sample contain PFOA or PFOS at or above the reporting level?

For a U.S. public water system subject to UCMR 5, will its first entry-point sample contain PFOA or PFOS at or above the UCMR 5 minimum reporting level?

Derived from U.S. Environmental Protection Agency (EPA). This is not its official product.

Prediction time: Immediately before the first UCMR 5 entry-point sample is collected, recorded as CollectionDate; current-sample result fields are excluded. System attributes and prior UCMR 3 results are treated as pre-sample. Self-reported additional-data elements are attached only when the additional-data row matches the exact available system, facility, sample point, and sample event key, or the exact system, facility, and sample point key when no event code exists; unmatched rows remain missing and no system-level or cross-event fallback is used. The additional-data responses are undated self-reports, so their availability at the decision instant is assumed, not verified.

Evaluation scope: retrospective_research. Public validation is development data. The downloadable labeled holdout is public; it is not cryptographically sealed. No final holdout benchmark score is claimed.

Measured baseline

The existing runner was used unchanged on public validation. See evaluation.json for rows, controls, per-year results and limitations.

{
  "full_model": {
    "auc": 0.7856421356421357,
    "brier": 0.06860848158758656
  },
  "majority_prior": {
    "auc": 0.5,
    "brier": 0.0766306076535297
  },
  "calendar_identity": {
    "auc": 0.5,
    "brier": 0.0766306076535297
  },
  "persistence": {
    "auc": 0.4525491493644361,
    "brier": 0.08101381885983604
  }
}

Limitations

  • UCMR 5 is occurrence monitoring at entry points, not compliance monitoring; a result at or above the MRL is not a violation or a determination that the system exceeds an MCL.
  • The first sample is a single snapshot at one entry point; systems with multiple facilities or sample points can have heterogeneous PFOA/PFOS results, so the label is sample-level, not a system-wide contamination determination.
  • The final UCMR 5 dataset was released in 2026; system size is as of February 1, 2021, prior UCMR 3 files were revised in 2024, and self-reported additional data elements may have been updated after sampling. This is current-vintage retrospective research, not proof of historical operational availability.
  • Results below the UCMR 5 MRL are censored (null), so the label captures detection at the reporting threshold, not concentration magnitude or low-level exposure.
  • First-sample collection dates are determined by monitoring schedules rather than random assignment; chronological splits can reflect rollout differences by system size, state, and laboratory capacity.
  • UCMR 5 covered community water systems and non-transient non-community water systems, not transient non-community systems, and small-system participation was a nationally representative sample rather than a census.
  • EPA's public-domain designation is a U.S. domestic basis; reusers outside the United States must assess local rights. Any CC0 release of the derived table applies only to that contribution and does not alter EPA's upstream designation.
  • This is a predictive association task, not a causal analysis of source-water contamination or treatment effectiveness.
  • The final UCMR 5 file includes samples collected through mid-2026, beyond the January 2023 through December 2025 monitoring-cycle text on the occurrence page; the frozen holdout window follows the observed data through 2026-06-30.
  • UCMR 5 is occurrence monitoring at entry points, not compliance monitoring; a result at or above the minimum reporting level is not a violation or an MCL determination.
  • The label is sample-level at one entry point; systems with multiple facilities or sample points can have heterogeneous PFOA or PFOS results.
  • The final UCMR 5 dataset was released in 2026; system size reflects a 2021 vintage, UCMR 3 files were revised, and self-reported additional data elements may have been edited after sampling. This is current-vintage retrospective research, not proof of historical operational availability.
  • Results below the UCMR 5 minimum reporting level are censored, so the label captures detection at the reporting threshold, not concentration magnitude.
  • First-sample collection dates follow monitoring schedules rather than random assignment, so chronological splits can reflect rollout differences by system size, state, and laboratory capacity. First samples whose dates fall in the December embargo or outside the windows are excluded by the fixed first-sample selection and are counted in a source check, so a system whose earliest sample falls there is not represented even if a later in-window sample exists.
  • Samples with a blank CollectionDate are excluded and counted before first-sample selection; they are not assigned to any split.
  • UCMR 5 covered community water systems and non-transient non-community water systems, not transient non-community systems, and small-system participation was a representative sample rather than a census.
  • Additional data element concepts are stored as rows in the AdditionalDataElement field rather than as header columns. The builder filters documented values and attaches Response values only through the exact available system, facility, sample point, and sample event key, or the exact system, facility, and sample point key when no event code exists. It never falls back to a system-only join. Unmatched rows remain missing. The additional-data responses are undated self-reports, so pre-sample availability is assumed rather than proven.
  • For UCMR 3 systems with only non-detect PFOA or PFOS rows, the prior maximum uses the maximum reported MRL as a sourced censoring bound, not an observed concentration and not zero. The prior maximum is missing only when the system has no UCMR 3 PFOA or PFOS row.
  • The occurrence text file carries a non-UTF-8 micro sign byte in the concentration unit text; the builder decodes publisher text with the Windows-1252 codec and checks UCMR 5 and UCMR 3 units.
  • The label check uses an independent csv-module pass over the occurrence text and compares the written labels, source signs, source values, units, and MRLs; it does not rely on the in-memory pandas label expression.
  • collection_year is constant within the train and eval windows and is a split tag, not a transferable feature.
  • No uncertainty interval; observed differences do not establish universal headroom

Loading and reproduction

Verify all downloaded files with verify_dataset.py. CSV splits live under extract/; meta.json declares the target and identifiers. MANIFEST.json binds data, source snapshot, code and measured evidence.

To reconstruct without network source drift, extract source-snapshot.tar.gz into a new cache directory, install reproduction/requirements.txt in an isolated Python environment, then run python reproduction/dataset_run.py --output NEW_EMPTY_DIRECTORY --source-cache CACHE_DIRECTORY. Compare the qualification artifact digest with this manifest. This performs full validation and baseline evaluation and may need worker resources.

See LICENSE.md for source terms and preserved attribution.

Downloads last month
174