| # Stimulus description
|
| In Eyewire2 stimuli were chirp, moving bar (MB) and mouse camera movies (MCs).
|
|
|
| The original QDSpy stimulator scripts for [chirp](./QDSpy/Chirp.py), [MB](./QDSpy//DS.py)
|
| and [MCs](./QDSpy/MouseCam_Right.py) are included in this folder.
|
|
|
| ## Chirp
|
| The chirp had a spot with a diameter of 1000 µm and otherwise follows previous publications.
|
| [Chirp PDF](./global_chirp/chirp1000_setup3.pdf)
|
|
|
| ## Moving bar
|
| The moving bar directions in the script were (0, 180, 45, 225, 90, 270, 135, 315) degrees.
|
| In the setup chamber this resulted in the following directions of the moving bar (↓, ↑, ↙, ↗, ←, →, ↖, ↘), where e.g. "↓" means back to front.
|
| The bar width (the dimension that is orthogonal to the direction of motion) was 300 µm, the speed 1000 µm/s, and the length 1000 µm.
|
| [Moving Bar PDF](./moving_bar/DS_setup3.pdf)
|
|
|
| ### Retina orientation
|
| The retina was from the right eye. Ventral was in the back of the setup chamber.
|
| So this is the orientation of the retina in the setup chamber:
|
| ```
|
| ----- Ventral ----
|
| Nasal ---- Temporal
|
| ----- Dorsal -----
|
| ```
|
| For the MB, 0° therefore means ventral to dorsal motion.
|
| 90° means temporal to nasal motion.
|
|
|
| In the manuscript the retina is depicted as (i.e. with a 180° rotation compared to the setup chamber):
|
| ```
|
| ------ Dorsal -----
|
| Temporal ---- Nasal
|
| ------ Ventral ----
|
| ```
|
| In this projection (0, 180, 45, 225, 90, 270, 135, 315) corresponds to (↑, ↓, ↗, ↙, →, ←, ↘, ↖).
|
|
|
| ## Mouse camera movies
|
| MCs were similar as in [Höfling et al. 2024](https://elifesciences.org/articles/86860) which were derived from recordings by [Qiu et al. 2021](https://www.cell.com/current-biology/fulltext/S0960-9822(21)00676-X).
|
| There are different MC stimuli, e.g. MC-16 and MC-20, that are all based on the same 113 five-second movie clips.
|
| Each MC stimulus MC-X is described by a sequence [test/train1-X/test/train2-X/test](https://iiif.elifesciences.org/lax:86860%2Felife-86860-fig1-v1.tif/full/1500,/0/default.jpg),
|
| where:
|
| - the test sequence, consisting of five movie clips, is the same for all MC versions and is shown three times (the beginning, the middle and the end),
|
| - and the train sequences train1-X and train2-X consist of 54 movie clips, each, that are differently ordered for each MC stimuli MC-X.
|
|
|
| Each MC therefore consists of a sequence of 123 five-second movie clips, with 123 corresponding triggertimes.
|
| The order of the train sequences is stored in [RandomSequences.txt]().
|
| With [mc_to_numpy.py]() you can generate numpy arrays that correspond to the MC stimuli.
|
| With [mc_arrays/load_mc_array.ipynb]() you can display them as they would appear in QDSpy.
|
| In the setup chamber the movies were rotated by 90 degrees counter-clockwise.
|
|
|