Clip ID
stringlengths
3
3
Show
stringclasses
6 values
Premiere Year
int64
2k
2.03k
Scene Start
stringlengths
5
5
Scene End
stringlengths
5
5
Season
stringclasses
13 values
Episode
stringclasses
25 values
Summary
stringlengths
62
703
Efficiency
stringlengths
15
240
⌀
Ethical Violations
stringlengths
48
378
⌀
Breach of Standards of Care
stringlengths
41
528
⌀
Patient Outcome
stringlengths
8
332
⌀
301
The Resident
2,018
00:45
02:32
2
5
Doctors makin deals with medical device ceo and accepting generous stipends and pushing medical devices to all the surgical patients and moving away from tested devices which have shown good pt outcomes, unethical to obtain or make deals with medical device ceos.
null
Conflict of interest between surgeons and medical device companies. Prioritizing financial gains.
Moving away from tested devices and evidence-based surgical standards with established long-term outcomes due to financial gains. Inadequate disclosure of financial relationships and conflicts of interest.
deal finalized with 25% discount on devices and luxury perks for the ceo.
302
The Resident
2,018
05:00
06:00
2
5
Medicine doctor seeing pediatric patient. Unethical and could be dangerous.
null
Potentially unethical scope-of-practice concerns if physicians work outside their primary expertise without appropriate supervision or consultation.
Failure to prioritize pediatric specialty evaluation when clinically indicated;
not shown, pt later showed in pediatric unit.
303
The Resident
2,018
26:55
27:30
2
8
IM doctor doing code blue for 1 hr without proper code blue team. Only had 1 nurse doing ambu bag, and only one other compressor. pt declared dead after 1 hr of cpr.
No proper code blue team, leading to poor quality resuscitation can lead to poor patient outcomes including anoxic brain injury, to death.
null
Medical futility not recognized and extended CPR performed out of emotional sentiments, without proper staff and code team.
Pt declared dead
304
The Resident
2,018
30:00
31:00
2
8
Ceo of the hospital/chief of surgery having family meeting for a treatment option for epilepsy with a novel VNS device which only has FDA certification but no data available for peds population. As ceo has cut a deal with the device company to push for their devices in the patient population.
Recommending a medical device which is not FDA approved to a pediatric patient without proper clinical trials in children puts them at risk of worse clinical outcomes including death.
null
Medical devices or medicine with evidence based and good clinical trial data, with established safety and side effects should be recommended by the physicians to the patients. Endorsing out of financial commitments and financial gains is a conflict of interest and ethically wrong and can be harmful to the patient.
Pt had VNS malfunctions causing cardiac arrest, but survived.
305
House M.D.
2,004
11:30
12:45
3
1
pt complaint of SOB, without doing xray concerned about pleural effusion, takes a syringe and going to do thoracentesis but then looks at the JVD and stabs the patient in the chest with the long needle and aspirates pericardial effusion.
No imaging done
null
no imaging done, no echo done, intervention without sterile technique, pt should be manged in either cath lab or IR should have done the procedure. again later in the scene pt now intubated and pericardiocentesis done blindly by the bedside.
shortness of breath improved
306
House M.D.
2,004
36:10
37:12
3
4
dr. House making diagnosis of cocciodes imitis infection in a patient shown to have milky white tears and loss of inhibitions (hypersexuality towards the Dr. House) in a young female. And hand a prescription based on these two symptoms 
null
null
Not a symptom of coccoides imitis infection, wrong diagnosis wrong symptoms. 
patient was given presciption based on clinical decision made based on symptoms that are not typical for the disease. likely wrong diagnosis and treatment.