"video": "video/laparoscopic_sample_001_intracorporeal.mp4",
"status": "visual review by Claude (AI); reviewed and approved by the contributing physician on 2026-11-17",
"method": "One thumbnail every 4 s over the whole video (overview_sheets/), plus frame-by-frame review of source frames 17350-17398 for the end boundary. Segment boundaries are therefore accurate to about +/-4 s unless stated.",
"vocabulary_note": "Descriptions name only what is visible. No procedure name, anatomy name, pathology or device model is asserted. A surgeon must map these scene segments onto a procedure-specific phase/step ontology before they are used as phase labels.",
"instrument_appearance_classes": {
"fenestrated_grasper": "jawed instrument with an open-window jaw on a dark shaft",
"white_insulated_jawed": "jawed instrument with cream/white insulation behind the jaws",
"dark_rod": "dark cylindrical rod without visible jaws"
},
"segments": [
{"id": 1, "start_s": 0, "end_s": 48, "label": "wide_view_manipulation",
"description": "Wide view of a smooth rounded surface carrying pale adherent material. A fenestrated grasper and a dark rod move tissue around a dark, bleeding spot below the pale material.",
"instruments_seen": ["fenestrated_grasper", "dark_rod"], "gauze_visible": "from about 28 s, lower-left edge", "confidence": "medium"},
{"id": 2, "start_s": 48, "end_s": 70, "label": "gauze_placement",
"description": "A fresh white gauze with a blue marker thread is brought into the field and positioned with the grasper and the rod.",
"instruments_seen": ["fenestrated_grasper", "dark_rod"], "gauze_visible": "yes", "confidence": "high"},
{"id": 3, "start_s": 70, "end_s": 132, "label": "instrument_change_and_alternating_views",
"description": "A white-insulated jawed instrument is now in use with the rod. The camera alternates between the upper site with pale material and a lower field of yellow fatty lobules. The gauze becomes blood-stained.",
"instruments_seen": ["white_insulated_jawed", "dark_rod"], "gauze_visible": "most of the segment", "confidence": "medium"},
{"id": 4, "start_s": 132, "end_s": 200, "label": "close_work_lower_field",
"description": "Close work among yellow fatty lobules. The white-insulated instrument opens, closes and spreads tissue while the rod holds tissue aside. Stained gauze sits at the left edge.",
"instruments_seen": ["white_insulated_jawed", "dark_rod"], "gauze_visible": "yes", "confidence": "medium"},
{"id": 5, "start_s": 200, "end_s": 244, "label": "oozing_surface_view",
"description": "View moves to a smooth pale surface with diffuse oozing; pooled blood fills much of the frame around 228-236 s. Instrument shafts pass close to the lens.",
"instruments_seen": ["white_insulated_jawed", "dark_rod"], "gauze_visible": "intermittent", "confidence": "medium"},
{"id": 6, "start_s": 244, "end_s": 300, "label": "return_to_lower_field",
"description": "Back in the fatty-lobule field. Gauze is repositioned (whiter gauze visible about 270-276 s). About 280-288 s is a close view of a bleeding surface with one instrument tip.",
"instruments_seen": ["white_insulated_jawed", "dark_rod"], "gauze_visible": "yes", "confidence": "medium"},
{"id": 7, "start_s": 300, "end_s": 412, "label": "sustained_work_single_site",
"description": "Sustained work at one site: the white-insulated jaws are applied repeatedly to tissue at the base of a yellow lobule with the rod alongside. Dark blood pools at the left and the gauze is soaked. The camera is nearly static from about 360 s.",
"instruments_seen": ["white_insulated_jawed", "dark_rod"], "gauze_visible": "yes", "confidence": "medium"},
{"id": 8, "start_s": 412, "end_s": 428, "label": "haze_episode",
"description": "The instrument tip looks charred at about 412 s and the view is hazy at about 416-424 s.",
"instruments_seen": ["white_insulated_jawed", "dark_rod"], "gauze_visible": "partly", "confidence": "medium"},
{"id": 9, "start_s": 428, "end_s": 470, "label": "upper_site_pale_material",
"description": "Return to the upper site. Instruments handle and lift the pale adherent material; from about 440 s the field is mostly free of instruments, with haze around 448-452 s.",
"instruments_seen": ["white_insulated_jawed", "dark_rod"], "gauze_visible": "no", "confidence": "medium"},
{"id": 10, "start_s": 470, "end_s": 490, "label": "close_view_darkened_tissue",
"description": "Close view of a dark, charred-looking tissue area with the white-insulated instrument next to it.",
"instruments_seen": ["white_insulated_jawed", "dark_rod"], "gauze_visible": "no", "confidence": "medium"},
{"id": 11, "start_s": 490, "end_s": 600, "label": "lower_field_near_lens_instrument",
"description": "Lower field again. A near-lens instrument shaft often fills a large part of the frame (for example about 500, 504, 564, 572, 584, 596 s). Work continues on dark purplish tissue beside a yellow lobule; gauze is soaked.",
"instruments_seen": ["white_insulated_jawed", "dark_rod"], "gauze_visible": "yes", "confidence": "medium"},
{"id": 12, "start_s": 600, "end_s": 694.8, "label": "continued_work_same_site",
"description": "Continued work at the same site with small yellow nodular fragments visible. A fenestrated jaw appears about 648 s. Ends just before the camera leaves the field.",
"instruments_seen": ["white_insulated_jawed", "dark_rod", "fenestrated_grasper (about 648 s)"], "gauze_visible": "intermittent", "confidence": "medium",
"end_boundary_precision": "frame-accurate (source frame 17370)"}
],
"point_events": [
{"t_s": 50, "event": "fresh_gauze_enters_field", "precision_s": 4},
{"t_s": 70, "event": "white_insulated_instrument_first_seen", "precision_s": 4},
{"t_s": 412, "event": "instrument_tip_looks_charred", "precision_s": 4},
{"t_s": 420, "event": "haze_in_view", "precision_s": 4},
{"t_s": 450, "event": "haze_in_view", "precision_s": 4},
{"t_s": 694.96, "event": "camera_starts_leaving_field (source frame 17374; removed from the pack video)", "precision_s": 0.08}
],
"removed_from_pack": {"source_frames": "17370-17928", "source_seconds": "694.80-717.16",
"reason": "camera withdrawal through the port, then operating-room view (drapes, floor, equipment). In an 18-frame-step review of this span no face or readable text was seen; not every frame was inspected."}
}