File size: 7,811 Bytes
68d32d3
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
{
  "name": "first-drop",
  "title": "Initial PCB-based Experimental Device Sample Recordings",
  "id": "c40f94d8-46bb-4f93-8ed6-5f5e28c8132b",
  "description": "Pilot dataset from an integrated experimental device used for multi-channel process monitoring at miniature scales. Includes synchronized telemetry from laboratory instruments, connection mapping, quality-control annotations, image metadata, and run logs. The run represents a multi-day automated process trial using standard test materials.",
  "keywords": ["telemetry", "multichannel", "timeseries"],
  "licenses": [
    {
      "name": "CC-BY-4.0",
      "path": "https://creativecommons.org/licenses/by/4.0/"
    }
  ],
  "contributors": [
    {
      "title": "Iku Bio",
      "role": "maintainer"
    }
  ],
  "created": "2025-09-25T00:00:00Z",
  "modified": "2025-10-03T00:00:00Z",
  "version": "0.1.0",
  "language": "en",
  "sources": [
    {
      "title": "Instrument telemetry (DMM, LCR meter, oscilloscope, pump controller)",
      "path": "dataset-001/runs/run-0001/timeseries/"
    },
    {
      "title": "Experimental protocols and SOPs",
      "path": "dataset-001/protocols/"
    }
  ],
  "resources": [
    {
      "name": "connection_map",
      "path": "devices/connection_map.csv",
      "format": "csv",
      "mediatype": "text/csv",
      "description": "Mapping between devices, sensors, and instruments.",
      "schema": {
        "fields": [
          {"name": "connection_tag", "type": "string", "description": "Short identifier for connection"},
          {"name": "connection_uuid", "type": "string", "description": "UUID for connection", "constraints": {"required": false}},
          {"name": "device_tag", "type": "string", "description": "Device tag"},
          {"name": "sensor_tag", "type": "string", "description": "Sensor tag", "constraints": {"required": false}},
          {"name": "instrument_tag", "type": "string", "description": "Instrument tag"},
          {"name": "connection_type", "type": "string", "description": "Type of linkage or channel between modules."},
          {"name": "unit", "type": "string", "description": "Unit of measurement", "constraints": {"required": false}},
          {"name": "notes", "type": "string", "description": "Free-text notes", "constraints": {"required": false}}
        ]
      }
    },
    {
      "name": "qc_flags",
      "path": "runs/run-0001/qc_flags.csv",
      "format": "csv",
      "mediatype": "text/csv",
      "description": "Quality control annotations (operator notes, instrument events, environment changes).",
      "schema": {
        "fields": [
          {"name": "flag_tag", "type": "string"},
          {"name": "flag_uuid", "type": "string", "constraints": {"required": false}},
          {"name": "time_ns", "type": "integer", "description": "Epoch nanoseconds", "constraints": {"required": false}},
          {"name": "time_utc_iso8601", "type": "datetime"},
          {"name": "flag_type", "type": "string"},
          {"name": "severity", "type": "string", "constraints": {"enum": ["INFO","WARNING","CRITICAL"]}},
          {"name": "sensor_tag", "type": "string", "constraints": {"required": false}},
          {"name": "instrument_tag", "type": "string", "constraints": {"required": false}},
          {"name": "value_state", "type": "string", "constraints": {"enum": ["VALID","INVALID","MISSING","NA"]}},
          {"name": "details", "type": "string"},
          {"name": "reviewer", "type": "string"}
        ]
      }
    },
    {
      "name": "images",
      "path": "runs/run-0001/images.csv",
      "format": "csv",
      "mediatype": "text/csv",
      "description": "Image metadata linked to run and sample. Images are representative and do not depict device architecture.",
      "schema": {
        "fields": [
          {"name": "image_uuid", "type": "string", "constraints": {"required": false}},
          {"name": "file_name", "type": "string"},
          {"name": "file_hash", "type": "string", "description": "Hexadecimal SHA-256 digest of file contents", "constraints": {"required": false}},
          {"name": "time_ns", "type": "integer", "constraints": {"required": false}},
          {"name": "time_utc_iso8601", "type": "datetime"},
          {"name": "run_tag", "type": "string"},
          {"name": "sample_tag", "type": "string"},
          {"name": "instrument_tag", "type": "string"},
          {"name": "notes", "type": "string", "constraints": {"required": false}}
        ]
      }
    },
    {
      "name": "dmm_01",
      "path": "runs/run-0001/timeseries/dmm-01.csv",
      "format": "csv",
      "mediatype": "text/csv",
      "description": "Voltage or resistance readings from standard laboratory instrumentation.",
      "schema": {
        "fields": [
          {"name": "time_ns", "type": "integer"},
          {"name": "recorder_time_s", "type": "number"},
          {"name": "instrument_tag", "type": "string"},
          {"name": "sensor_tag", "type": "string"},
          {"name": "func", "type": "string"},
          {"name": "value", "type": "number"},
          {"name": "value_state", "type": "string", "constraints": {"enum": ["VALID","INVALID","MISSING","NA"]}},
          {"name": "unit", "type": "string"}
        ]
      }
    },
    {
      "name": "oscope_01",
      "path": "runs/run-0001/timeseries/oscope-01.csv",
      "format": "csv",
      "mediatype": "text/csv",
      "description": "High-frequency analog measurement channel recorded via oscilloscope.",
      "schema": {
        "fields": [
          {"name": "time_ns", "type": "integer"},
          {"name": "recorder_time_s", "type": "number"},
          {"name": "instrument_tag", "type": "string"},
          {"name": "device_tag", "type": "string"},
          {"name": "channel", "type": "integer"},
          {"name": "meas", "type": "string"},
          {"name": "value", "type": "number"},
          {"name": "value_state", "type": "string", "constraints": {"enum": ["VALID","INVALID","MISSING","NA"]}},
          {"name": "unit", "type": "string"}
        ]
      }
    },
    {
      "name": "lcr_meter_01",
      "path": "runs/run-0001/timeseries/lcr-meter-01.csv",
      "format": "csv",
      "mediatype": "text/csv",
      "description": "Frequency-swept instrument data captured from an experimental device.",
      "schema": {
        "fields": [
          {"name": "time_ns", "type": "integer"},
          {"name": "recorder_time_s", "type": "number"},
          {"name": "instrument_tag", "type": "string"},
          {"name": "sensor_tag", "type": "string"},
          {"name": "frequency_hz", "type": "string"},
          {"name": "primary", "type": "number"},
          {"name": "secondary", "type": "number"},
          {"name": "comp", "type": "integer", "constraints": {"required": false}},
          {"name": "value_state", "type": "string", "constraints": {"enum": ["VALID","INVALID","MISSING","NA"]}},
          {"name": "unit", "type": "string", "constraints": {"required": false}}
        ]
      }
    },
    {
      "name": "pump_controller_01",
      "path": "runs/run-0001/timeseries/pump-controller-01.csv",
      "format": "csv",
      "mediatype": "text/csv",
      "description": "Actuator control telemetry (setpoint and feedback).",
      "schema": {
        "fields": [
          {"name": "time_ns", "type": "integer"},
          {"name": "recorder_time_s", "type": "number"},
          {"name": "instrument_tag", "type": "string"},
          {"name": "device_tag", "type": "string"},
          {"name": "parameter", "type": "string"},
          {"name": "value", "type": "number"},
          {"name": "value_state", "type": "string", "constraints": {"enum": ["VALID","INVALID","MISSING","NA"]}},
          {"name": "unit", "type": "string"}
        ]
      }
    }
  ]
}