id stringlengths 14 14 | text stringlengths 3 7k | source stringclasses 1
value |
|---|---|---|
6ad148c5db78-1 | CANNOT BE ACCESSED.
Reason:
The flagged variables within the PL/I program were unreferenced.
Action:
Informational only. The flagged variables cannot be viewed online.
SYMP115W
THE FOLLOWING LINE CONTAINS "%NOPRINT" WHICH COULD PREVENT PROPER RESOLUTION OF SOME
VARIABLES. input compiler record
1784 | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
369e233499d4-0 | InterTest™ and SymDump ® 11.0
Reason:
Use of the compiler option %NOPRINT may cause the suppression of information needed to resolve variables properly.
Action:
Ensure that %NOPRINT does not suppress the printing of:
•
•PROCEDURE or ENTRY statements containing parameter lists.
•
•Declarations of redefined variables usi... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
4d644afc4d24-0 | InterTest™ and SymDump ® 11.0
•
•Selection of an incorrect variable
•
•Incorrect attributes for a variable
•
•Incorrect resolution of parameters
•
•System errors not apparently related to these variables
•
Action:
Assign unique names.
SYMP119W
NO AUTOMATIC VARIABLES FOUND FOR PROCEDURE procnamePARAMETER parameter CANNO... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
4d644afc4d24-1 | THE FOLLOWING VARIABLES CAN ONLY BE ACCESSED THROUGH CA INTERTEST BATCH.
Reason:
The flagged variables within the PL/I program are not supported.
Action :
Informational only. The flagged variables cannot be viewed online.
1786 | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
b7e021e10ccc-0 | InterTest™ and SymDump ® 11.0
SYMP123W
THE FOLLOWING EXTERNAL VARIABLES CANNOT BE ACCESSED THROUGH CA INTERTEST BATCH DUE TO
THE RENT OPTION.
Reason:
The flagged variables within the PL/I program are not supported.
Action:
Informational only. The flagged variables cannot be viewed with the use of the RENT option.
SYMP1... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
b7e021e10ccc-1 | USED.PARAMETER parameter CANNOT BE RESOLVEDDRC = n.
Reason:
The compiler generated times stamp cannot be found in the //SYSPRINT listing used as input. This may occur because
SymDump for CICS failed to find the date/time record. The date and time of the postprocessor's execution is used in lieu
of the compiler timest... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
f868297fec64-0 | InterTest™ and SymDump ® 11.0
Note: For messages SYMP500 to SYMP599: You are advised to contact Broadcom Support . Provide the message
number, text, and DRC code (if available). Also provide the IN25SYMP version ID and compile date and time (see
message SYMP001I) and the release number of the PL/I compiler you are usi... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
f868297fec64-1 | Action:
Call Broadcom Support .
SYMP503E
WARNING — THE FOLLOWING LINE ASSUMED TO BE PART OF COMPILER INFORMATORY MESSAGE AND
IGNORED: input compiler recordDRC = n.
Reason:
The specified compiler input record was ignored.
Action:
Call Broadcom Support .
SYMP503E0
WARNING — THE FOLLOWING LINE ASSUMED TO BE A REPETITIO... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
841beb2745c2-0 | InterTest™ and SymDump ® 11.0
Call Broadcom Support .
SYMP503E1
WARNING — THE FOLLOWING LINE ASSUMED TO IDENTIFY COMPILER DIAGNOSTIC MESSAGES SECTION:
input compiler recordDRC = n.
Reason:
The specified compiler input record was assumed to identify the compiler's diagnostic messages section.
Action:
Call Broadcom Sup... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
4a3a95d1a457-0 | InterTest™ and SymDump ® 11.0
Action:
Call Broadcom Support .
SYMP508E
SEARCH FAILED FOR: variableDRC = n
Reason:
The specified variable could not be found.
Action:
Call Technical Support.
SYMP509E
INCLUDE OF USER FILES THROUGH INTEGRATED PREPROCESSOR NOT SUPPORTED. USE SEPARATE
PREPROCESSOR STEP
Reason:
The integrated... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
4a3a95d1a457-1 | Reason:
The specified variable is already resolved.
1790 | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
e172b0b7a85d-0 | InterTest™ and SymDump ® 11.0
Action:
Call Broadcom Support and provide the information in the message.
SYMP599E3
AGGREGATE NAME NOT MATCHED aggregate name DRC = n.
Reason:
The specified aggregate name was not found.
Action:
Call Broadcom Support and provide the information in the message.
SYMP599E4
FORWARD SCAN FAI... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
e172b0b7a85d-1 | table, programs with over 9,999 statements cannot be supported completely. This message is usually accompanied by
other error messages. Online debugging is affected significantly.
Action:
None.
1791 | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
3efd9b88f784-0 | InterTest™ and SymDump ® 11.0
SYMP901S
THE PL/I COMPILER OPTIONS LISTED ABOVE WERE NOT SPECIFIED AND HAVE CAUSED IN25SYMP TO
TERMINATE
Reason:
One or more SYMP107W message(s) were issued.
Action:
Ensure that the following options were specified to the PL/I compiler:
AGGREGATE
OPTIONS
ATTRIBUTES(FULL)
SOURCE
MAP
STATEME... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
3efd9b88f784-1 | IN25ASMP FUNCTION FAILED. FUNCTION CODE= n DRC = n.
Reason:
The routine that does I/O to the PROTSYM file returned with a nonzero return code.
Action:
Check the error messages from IN25ASMP and take appropriate action, and then rerun the job. This error normally
indicates a problem with the PROTSYM file. If this is the... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
20d4b25f10ca-0 | InterTest™ and SymDump ® 11.0
NOTE
Function code 8 usually means the file is full.
SYMP905S
ERROR ENCOUNTERED ON FILE INPUTT, ERROR CODE = nnnnDRC = n.
Reason:
An error has occurred trying to open the INPUTT file.
Action:
Ensure that the ddNAME/DLBL INPUTT points to a file that contains the output listing of the PL/I c... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
20d4b25f10ca-1 | terminated or terminated with a return code greater than 8. Check for these conditions and if they occur, correct and rerun
the job. If neither has occurred, contact Broadcom Support with the dump.
SYMP910S
SUBSCRIPT OVERFLOW IN TABLE T6DRC = n.
Reason:
An internal table used to keep track of information about stateme... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
6e59c60094fb-0 | InterTest™ and SymDump ® 11.0
This can also occur if the PL/I preprocessor command %NOPRINT was specified. In this case, remove the %NOPRINT
command.
SYMP911S
SUBSCRIPT OVERFLOW IN TABLE T6ADRC = n.
Reason:
An internal table used to keep track of information about statements has overflowed.
Action:
This occurs under se... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
6e59c60094fb-1 | Reason:
For VSE only. Probably, a control card is either missing or invalid. Or, there may be a problem with the Symbolic File or
with the JCL for the "MESSAGE" file.
Action:
Correct the control card, Symbolic File, or JCL.
SYMP919S
END OF FILE ENCOUNTERED FOR "INPUTT" DURING PHASE 1 OF PREPROCESSORDRC = n.
Reason:
An ... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
c0f0b3caed52-0 | InterTest™ and SymDump ® 11.0
SYMP920S
"CDLOAD" FAILED FOR "IN25ASMP". RETURN CODE = nnnn
Reason:
VSE only. The VSAM I/O routine, IN25ASMP, could not be dynamically loaded. Possible causes include incorrect
installation or partition/JCL that does not allow sufficient storage for loading this phase.
Action:
Check that t... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
c0f0b3caed52-1 | support is limited to programs with less than 10,000 statements, this situation is unlikely to occur.
Action:
Call Broadcom Support and provide the information in the message.
SYMP924S
SUBSCRIPT OVERFLOW IN TABLE T7
Reason:
The internal table used to keep track of variable displacements has exceeded its limits.
Action... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
5cc1599159f6-0 | InterTest™ and SymDump ® 11.0
SYMP925S
SUBSCRIPT OVERFLOW IN TABLE T10
Reason:
The internal table used to keep track of the pseudo register information for controlled variables has exceeded its limits.
Action:
This error is usually caused when the Attribute and Cross Reference section of the compile output could not be... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
5cc1599159f6-1 | Reserved
Action:
None, this is an informational message.
WD02
Reason:
The TWA size for the transaction ICDB is less than 1536.
1796 | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
df301c4af082-0 | InterTest™ and SymDump ® 11.0
Action:
Increase the TWA size for the ICDB transaction to 1536 or more.
WD03
Reason:
Reserved
Action:
None, this is an informational message.
WD09
Reason:
InterTest for CICS communication failure.
Action:
Ensure that the workstation GUI interface was not disconnected from the CICS region. ... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
df301c4af082-1 | transaction dump, and any relevant messages sent to the terminal or the systems console. For assistance, contact
Broadcom Support .
WD14
Reason:
Could not load the InterTest for CICS IN25CUI9 message block module.
Action:
Ensure that the InterTest for CICS load module library in the CICS DFHRPL contains IN25CUI9. If th... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
59e0fd37d64d-0 | InterTest™ and SymDump ® 11.0
WD15
Reason:
Could not load the InterTest for CICS IN25PGM2 module.
Action:
Ensure that InterTest for CICS has been successfully started. If InterTest for CICS was successfully started, then
activate the CICS auxiliary trace. Retry the sequence of events that caused the error. Then collect... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
59e0fd37d64d-1 | WD22
Reason:
The ICDB transaction was not initiated by the graphical user interface PC user.
Action:
Ensure that ICDB transaction was started by the InterTest for CICS PC user. Otherwise, activate the CICS auxiliary trace.
Then issue the InterTest for CICS CNTL=ITTRACE_ON and the ICDB TRACE_ON commands. Retry the seque... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
41d9473e1ddb-0 | InterTest™ and SymDump ® 11.0
Issue the InterTest for CICS CNTL=ITTRACE_ON command and the ICDB TRACE_ON command. Retry the sequence
of events that caused the error. Then collect the auxiliary trace, the transaction dump, and any relevant messages sent to
the terminal. For assistance, contact Broadcom Support .
WD45
Re... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
41d9473e1ddb-1 | WD49
Reason:
An internal TCP/IP macro failure; RECEIVE failure.
Action:
Activate the CICS auxiliary trace. Then issue the InterTest for CICS CNTL=ITTRACE_ON and ICDB TRACE_ON
commands. Retry the sequence of events that caused the error. Then collect the auxiliary trace, the transaction dump,
and any relevant messages s... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
479fd6a55292-0 | InterTest™ and SymDump ® 11.0
Activate the CICS auxiliary trace. Then issue the InterTest for CICS CNTL=ITTRACE_ON and ICDB TRACE_ON
commands. Retry the sequence of events that caused the error. Then collect the auxiliary trace, the transaction dump,
and any relevant messages sent to the terminal or the systems console... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
479fd6a55292-1 | WD62
Reason:
InterTest for CICS internal logic error; security authorization failure on an execution of an EXEC CICS command.
Action:
Activate the CICS auxiliary trace. Then issue the InterTest for CICS CNTL=ITTRACE_ON and ICDB TRACE_ON
commands. Retry the sequence of events that caused the error. Then collect the auxi... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
3258bb76ad26-0 | InterTest™ and SymDump ® 11.0
InterTest for CICS internal error; invalid TWA length.
Action:
The TWA size for the transaction must be equal to or greater than 1536 bytes. If it is equal to or greater than 1536 then
activate the CICS auxiliary trace.
Activate the CICS auxiliary trace. Then issue the InterTest for CICS C... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
3258bb76ad26-1 | Action:
None, this is an informational message.
CAWD121I
CA InterTest for CICS INTERNAL TRACE SET <OFF>
1801 | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
96c225761397-0 | InterTest™ and SymDump ® 11.0
Reason:
InterTest for CICS ICDB TRACE_ON command has been deactivated.
Action:
None, this is an informational message.
CAWD090W
CA InterTest for CICS PHASE <1> ABEND EXIT CALL <EXIT>
Reason:
InterTest for CICS graphical user interface abend processing has completed.
Action:
No action is re... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
96c225761397-1 | Broadcom Support .
CAWD018E
CA InterTest for CICS INTERNAL ERROR: INVALID_TWA_FUNC_REQUEST
Reason:
1802 | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
aa5eabfb992d-0 | InterTest™ and SymDump ® 11.0
Internal logic error: unknown TWA function request.
Action:
Activate the CICS auxiliary trace. Then issue the InterTest for CICS CNTL=ITTRACE_ON and the ICDB TRACE_ON
commands. Retry the sequence of events that caused the error. Then collect the auxiliary trace, the transaction dump,
and a... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
aa5eabfb992d-1 | CA InterTest for CICS INTERNAL ERROR: INVALID_TERMINAL_DATA
Reason:
The ICDB transaction was entered from a terminal with invalid data.
Action:
Retry the ICDB transaction with valid data. Otherwise, activate the CICS auxiliary trace. Then issue the InterTest for CICS
CNTL=ITTRACE_ON and the ICDB TRACE_ON commands. Retr... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
b7d4b2fe4b08-0 | InterTest™ and SymDump ® 11.0
Activate the CICS auxiliary trace. Then issue the InterTest for CICS CNTL=ITTRACE_ON and the ICDB TRACE_ON
commands. Retry the sequence of events that caused the error. Then collect the auxiliary trace, the transaction dump,
and any relevant messages sent to the terminal or the systems con... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
da0e2f7a0533-0 | InterTest™ and SymDump ® 11.0
UTIL005
XXXXXXXX RELOADED TO SYMBOLIC FILE
Reason:
Program XXXXXXXX was reloaded to the InterTest for CICS Symbolic File.
Action:
None.
UTIL006
XXXXXXXX RELOADED TO SYMBOLIC FILE AND HAS BEEN RENAMED TO YYYYYYYY
Reason:
Program XXXXXXXX was reloaded to the InterTest for CICS Symbolic File ... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
725d887ffa20-0 | InterTest™ and SymDump ® 11.0
Reason:
All requested functions have been performed and the InterTest for CICS Symbolic File was updated successfully.
Action:
None.
UTIL012
RELOAD PROCESSING STARTED FOR PROGRAM XXXXXXXX
Reason:
The RELOAD function began for program XXXXXXXX.
Action:
None.
UTIL047
XXXXXXXX MUST BE DELETED... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
dc6dd968a6c3-0 | InterTest™ and SymDump ® 11.0
The function requested requires a PASSWORD= parameter card. Only this request is ignored.
Action:
Add a PASSWORD= parameter card as the first parameter card in the job stream and resubmit the job.
UTIL051
PASSWORD INCORRECT
Reason:
The password provided on the PASSWORD= parameter card does... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
dc6dd968a6c3-1 | 11.
12.Resubmit the original job.
13.
Or:
1.
2.Using the UTILITY job, run a PURGE= request to free up space.
3.
1807 | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
43104b499441-0 | InterTest™ and SymDump ® 11.0
4.Resubmit the original job.
5.
UTIL054
PURGE INTERVAL INVALID OR MISSING — REQUEST NOT PROCESSED
Reason:
The PURGE= request either did not specify a number of days or the number of days specified was not within the range of
1 through 365. This request is ignored.
Action:
Correct the PURGE... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
8fdbffd720d6-0 | InterTest™ and SymDump ® 11.0
None.
UTIL060
REQUEST FOR VIRTUAL STORAGE FAILED
Reason:
The request for GETMAIN or GETVIS storage failed. The job is terminated.
Action:
Resubmit the entire job stream, using a bigger region size or run the job in a larger partition.
UTIL061
OPEN FAILURE FOR UNLOAD DEVICE
Reason:
The open... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
8fdbffd720d6-1 | empty. This request is ignored.
Action:
If a bad JCL caused the error, correct the JCL and resubmit the request; otherwise, the problem is not correctable.
1809 | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
16d3aec0b899-0 | InterTest™ and SymDump ® 11.0
UTIL066
XXXXXXXX ALREADY EXISTS IN FILE: RELOAD FOR THIS PROGRAM IGNORED
Reason:
The program to be reloaded already exists on the file. This request is ignored.
Action:
Delete the program, using a DELETE= request, and resubmit the RELOAD= request.
UTIL067
xxxxxxx yyyy ERROR R15 = X'rr' ERR... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
c6f2d0ff58f4-0 | InterTest™ and SymDump ® 11.0
UTIL072
ERROR OCCURRED WHILE READING RELOAD DEVICE (DOS)
Reason:
The system detected an error condition while reading a record from the device pointed to by SYS005. The job is
terminated.
Action:
Determine the cause of the error, correct the problem, and resubmit the entire job stream.
UTI... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
c6f2d0ff58f4-1 | BATCH UTILITY RUN UNSUCCESSFUL — ALL UPDATES HAVE BEEN BACKEDOUT
Reason:
This message is produced on any error condition that terminates the job. If this message is produced, all requested
functions, even if they were correct, are backed out.
Action:
After the error condition is corrected, the entire job stream must be... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
508c8304731c-0 | InterTest™ and SymDump ® 11.0
UTIL078
INTERTEST BATCH UTILITY RUN UNSUCCESSFULUPDATES HAVE NOT BEEN BACKED-OUT
Reason:
This message is produced when an error condition, which is not serious, has occurred. If this message is produced, only
the requests that were in error are ignored and all valid requests were performed... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
508c8304731c-1 | 2.Resubmit the original job.
UTIL101
INVALID RECORD ON FILE. UNLOAD AND RELOAD OF FILE RECOMMENDED
Reason:
1812 | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
1771e90ee0d8-0 | InterTest™ and SymDump ® 11.0
An invalid DATE/TIME field is found in a Program Master Index Record.
Action:
Unload and Reload of the PROTSYM file is recommended.
UTIL102
x22 CANCEL, ABEND PERCOLATED
Reason:
A system cancel event occurred while IN25UTIL was executing.
Action:
Capture the dump if needed.
UTIL103
RECOVERY... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
1771e90ee0d8-1 | UTIL106
MONTH CONTAINS NON NUMERIC DATA - REQUEST IGNORED
Reason:
1813 | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
9efc7bbf26f8-0 | InterTest™ and SymDump ® 11.0
The month specified for a DATETIME, BEFOREDATETIME, or AFTERDATETIME parameter contains a value which is not
numeric.
Action:
Correct the value and resubmit the request.
UTIL107
DAY CONTAINS NON NUMERIC DATA - REQUEST IGNORED
Reason:
The day specified for a DATETIME, BEFOREDATETIME, or AFT... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
6bbfa55f1b8e-0 | InterTest™ and SymDump ® 11.0
UTIL112
SECOND EXCEEDS MAXIMUM VALUE - REQUEST IGNORED
Reason:
The second specified for a DATETIME, BEFOREDATETIME, or AFTERDATETIME parameter contains a value which is
greater than or equal to 60.
Action:
Correct the value and resubmit the request.
UTIL113
SECOND CONTAINS NON NUMERIC DATA... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
993f9dce1c79-0 | InterTest™ and SymDump ® 11.0
UTIL119
INVALID DATA ENTERED - USEDSPACEMSG HAS BEEN SET TO 0.
Reason:
The valid value range for USEDSPACEMSG is 0-99.
UTIL120
FUNCTION NOT SUPPORTED IN THE VERSION OF PROTSYM.
Reason:
You used a function that is not supported in the current version of PROTSYM.
Action:
None.
UTIL121
INVALI... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
f24a4ebcb676-0 | InterTest™ and SymDump ® 11.0
UTIL200
EXTERNAL SECURITY IS <ON | OFF>
Reason:
The external security option in CAVHCONF is either ON or OFF.
Action:
None.
UTIL201
EXTERNAL SECURITY API IS MISSING
Reason:
The external security API, CAVHBAPI, cannot be loaded.
Action:
Add the load library that contains CAVHBAPI to the LIN... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
dc36f3248678-0 | InterTest™ and SymDump ® 11.0
Correct the CUTPRINT= option and resubmit your job stream.
SYM004
SYMBOLIC INFORMATION HAS BEEN SET AS NONPURGABLE
Reason:
The NOPURGE option was specified on the parameter statement.
Action:
None.
SYM005
PARAMETER OPTIONS INVALID, SYMBOLIC STEP NOT RUN
Reason:
An option was specified on t... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
7183ee7b1610-0 | InterTest™ and SymDump ® 11.0
SYM010
PROCESSING HAS BEGUN FOR PROGRAM NAME — XXXXXXXX
Reason:
Program XXXXXXXX is being processed and its output will reside on the InterTest for CICS Symbolic File.
Action:
None.
SYM011
SEQUENCE NUMBERS ARE NOT IN ASCENDING SEQUENCE. JOB WILL BE TERMINATED — CONTACT
Technical Support
Re... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
12b57a181ee1-0 | InterTest™ and SymDump ® 11.0
SYM016
ENQ ERROR — CODE = X'YY'
Reason:
In VSE, an error occurred when an SVC 63 (ENQ) was issued. This is normally caused by a NOT FOUND condition for
the InterTest for CICS Symbolic file.
Action:
Check the JCL and correct. Contact Broadcom Support if the JCL is correct.
SYM017
UTILITY I... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
7d8e9f1cba6e-0 | InterTest™ and SymDump ® 11.0
SYM022
YYYY TOTAL RECORDS INSERTED INTO SYMBOLIC FILE
Reason:
On a successful completion, the total number of records added to the InterTest for CICS Symbolic File, YYYY, displays.
Action:
None.
SYM023
POSTPROCESSOR TERMINATED
Reason:
The InterTest for CICS postprocessor program has ended.... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
5b2ccde5a2ad-0 | InterTest™ and SymDump ® 11.0
Reason:
Area XXXXX could not be found in the COBOL listing. For Working Storage, at least one data item must be declared.
Action:
Correct COBOL compiler options or add a Working Storage data item to produce the required area and resubmit the job
stream.
SYM029
XXXXX NOT REQUESTED — PROCESS... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
b71df12bb324-0 | InterTest™ and SymDump ® 11.0
SYM034
OPEN FOR CARDS FAILED
Reason:
The CARDS file could not be opened. Check the printed output for additional error messages that may have been
produced by the operating system.
Action:
Correct the JCL and resubmit the job stream.
SYM035
NO CROSSREFERENCE FOUND — SYMBOLIC NAMES CANNOT B... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
8ed82e6c5ce5-0 | InterTest™ and SymDump ® 11.0
SYM040
THE FOLLOWING OPTIONS WERE NOT SPECIFIED
Reason:
The list of options following this message was not specified. Without these options, some InterTest for CICS facilities may
not function.
Action:
Correct the JCL and resubmit the job stream.
SYM042
NO STATEMENT INFORMATION WAS FOUND I... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
8ed82e6c5ce5-1 | linkageeditor step or the linkage editor PARM=MAP is not in effect.
Action:
Correct the JCL and resubmit the job stream.
1824 | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
113cf4d2d5ac-0 | InterTest™ and SymDump ® 11.0
SYM045
INVALID POWER PARAMETER FORMAT
Reason:
The POWER= parameter was specified incorrectly.
Action:
Correct the parameter card and resubmit the job stream.
SYM046
INVALID POWER CLASS SPECIFIED (NOT A — Z)
Reason:
The POWER LST class specified on the parameter card was not an alphabetic c... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
f87b24884455-0 | InterTest™ and SymDump ® 11.0
Reason:
The POWER= parameter was specified incorrectly.
Action:
Correct the parameter card and resubmit the job stream.
SYM051
SYNTAX ERROR IN WH= OPTION
Reason:
A syntax error was found in the Realia Workbench Host Option parameter.
Action:
Correct the parameter card and resubmit the job ... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
6eac4ff0431b-0 | InterTest™ and SymDump ® 11.0
SYM057
CSECT NAME 'XXXXXXXX' IS GT 8 BYTES. CSECT IGNORED
Reason:
CSECT name is greater than 8 bytes.
Action:
Correct and resubmit the job.
SYM058
HLASM OPTION "LIST(133|MAX)" IS NOT SUPPORTED. USE OPTION "LIST(121)".
Reason:
HLASM option "LIST(133|MAX) is not supported.
Action:
Correct th... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
9ec7aec0bcb1-0 | InterTest™ and SymDump ® 11.0
SYM095
DIRECTORY RECORD IS CORRUPTED
SYM097
MISMATCH ON AVAILABLE FREE RECORDS IN ONE SAM
SYM099
MAXPGMVER WAS REACHED - OLDEST VERSION HAS BEEN DELETED TO PROCESS CURRENT REQUEST.
SYM960
MAX SAM RECS EXCEEDED. PROTSYM FILE MAY BE CORRUPTED
SYM961
MAX DIR RECS EXCEEDED. PROTSYM FILE MAY BE... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
00f4c2078629-0 | InterTest™ and SymDump ® 11.0
CAVH102E
CAVH102E
ERROR COPYING TOMCAT FILES
Reason:
Unable to copy Tomcat files.
Action:
Ensure you have access rights to the directories, that the directories exist, and that enough space is available in the target
directory.
CAVH103E
CAVH103E
ERROR COPYING FILE CAVHSVRX
Reason:
Th... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
d7e5448d6fa4-0 | InterTest™ and SymDump ® 11.0
Additional Resources
Includes educational resources, product references, and support information.
This article provides product resources, including education, webcasts, support, and maintenance, to help optimize your
product experience.
Education and Training
Use the following links to le... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
aacc628c599b-0 | InterTest™ and SymDump ® 11.0
Documentation Legal Notice
This Documentation, which includes embedded help systems and electronically distributed materials, (hereinafter referred
to as the “Documentation”) is for your informational purposes only and is subject to change or withdrawal by Broadcom
at any time. This Docume... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
aacc628c599b-1 | The use of any software product referenced in the Documentation is governed by the applicable license agreement and
such license agreement is not modified in any way by the terms of this notice.
The manufacturer of this Documentation is Broadcom Inc.
Provided with “Restricted Rights.” Use, duplication or disclosure by ... | /Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.