Current
... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 34 |
8752fe9c-44bf-4bd5-b5e0-04c4682d0764 | TEM transmission line grounded at both ends with a voltage maximum and a current
minimum located at the center of the spoke, figure 2.2 [65]. The 345 MHz eigenmode is
also referred to as the pi-mode, since the relative phase of the electric field differs by n
radians in adjacent gaps [13, 14]. A snapshot of the P = ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 34 |
e6e15af7-5df1-49c3-9e27-b130df1c11ba | where q is the particle charge, Ez(0,0,z) is the axial electric field, to is the angular
frequency of the electromagnetic field (=2 -nf), < / > is the phase of the electric field relative
to its peak accelerating magnitude at t = 0, the z-axis is chosen to lie along the beam path,
and the field profile was assumed... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 35 |
69f76f0c-1a34-4b0c-8467-2990283b2494 | Notice that the energy gain is maximized for an ion traveling at P = 0.5 for the TSR and
at p = 0.4 for the DSR. These values are defined as the geometric P of the cavity, pg e 0 m ,
and correspond to the particle velocity with the maximum voltage gain.
The cavity accelerating gradient, Eacc, is defined as:
VE = -S S... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 35 |
06935582-d57d-492c-a67d-41f8ac3526f0 | length of the proposed International Linear Collider (ILC) 1.3 GHz (p = 1) nine-
elliptical-cell cavity is 9-1-X72 = 103.8 cm [76]. Some references, primarily older, use the
exterior or interior physical length of the cavity. For example, the interior length of a
quarter-wave coaxial-line resonator (n = 1) discussed ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 35 |
fe508c3c-5727-4244-a854-4a9b18c132de | I t I # '» •6.9e6
6.03e6
5.17eG
4.31eG
3.45e6
Z.59e6
1 .7Ze6
861937w
* ■ * 4 t i V > »
-‘ .ovtaSl^L
; > ^ - 5 V ; 4 a~v^a - • *
*»«■»» * % % ' %
•» «* « > H B l % ^ ♦11Z15
5607-
« * * % »
Figure 2.3: Snapshots of the P = 0.5 TSR 345 MHz mode electric (top) and magnetic
(bottom) field. The figure was g... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 36 |
9dd8fa08-f11b-4d5b-8e1d-546806c97f40 | Axial Electric F ield (M V /m ) Axial Electric F ield < M V/m)6
Cavity S tored
E nergy = 1 J
-2 - -
p = 0.4 DSR
' 1 ■ 1 ■ 1 ' 1 1 1-
0 10 20 30 40 50
D istance Along Beam Axis (cm)
Cavity
S tored E nergy = 1 J
-2 - -P = 0.5 TSR
8 0 4 0 6 0 o 20
Distance Along Beam Axis(cm)
Figure 2.4: Axial elect... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 37 |
08e00a74-837c-4980-a285-cc06302a1f9e | Voltage G ain (M V ) Voltage G ain (MV)
due t o Axial Electric F ield due t o Axial Electric Field1.2
1 . 0 P = 0.4 DSR
0.8 —
0.6 —
0.2 —
Cavity Stored Energy = 1 J
o.o
-0.2 - -
-0.4
0.8 1.0 0.0 0.2 0.4 0.6
1.2
1.0-- p = 0.5 TSR
0.8 —
0.6 —
0.4 —
0.2 - -Cavity
S to red E nergy = 1 J
-0.2 - -
-0.4
1.0 0... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 38 |
277e0968-58e4-486c-b5ca-940e7d8347fb | 2.4 Electromagnetic and Mechanical Mode Interactions
2.4.1 Introduction
This section introduces the physics which describe the coupling process between the
RF field and the mechanical eigenmodes. This is necessary because the walls of a
superconducting cavity are not infinitely rigid. Consequently, the mechanical str... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 39 |
615a9ebd-44c6-4ff1-802d-a502d820195e | electromagnetic field. It will show that the changing in frequency is linear in the
displacement of the cavity surface. Hence, changes in the cavity frequency must obey the
same differential equation which describes the mechanical eigenmodes. It is the transfer
functions of the linear equation of motion which are ex... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 39 |
c17a7365-a795-4664-b2b7-9c2926f7fb9f | the parameter X . If X does not change much over a period of the motion, T:
T* — « A 2.5
dt
Then, according to the Boltzmann-Ehrenfest theorem, the ratio of the parameter X and the
stored energy, U , is a constant to as many orders in the rate of change of X as X has
continuous derivatives [44], This constant is re... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 39 |
9496d8c0-2e85-4479-b798-02809f6997cb | eigenfrequency of one of the electromagnetic eigenmodes in a loss-free resonant cavity
with eigenfrequency c o and stored energy U .
Applying the Boltzmann-Ehrenfest theorem to the case of a resonant cavity and using
the notation of Schulze in the limit where [45]:
2k dco---------- « (t) 2.6c o dt
yields:
( i i \ ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 40 |
3d3bf1b3-fdc2-4699-b620-e7900d16eff3 | where h is the inward unit normal vector at all points on the cavity RF surface. The work
done on the system is found by integrating the dot-product between the force density and
the surface displacement, u(x,t) , over the resonator surface, S:
A= ^[F(x,t)*u{x,t))da 2.10
s
The electromagnetic energy is given by the ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 40 |
a1a5dc6d-a8d7-4aaf-81d7-27b0fec50017 | f( ^ E(x, t) •E (x,t)-~ - H{x, t) • H(x, ol«(3c, t) • w(x, t) da
— = -— ------------ 1 j 2.12
® j j j £(x, 0 • E(x, t) + ^ (x, 0 • tf(x, 0 J t/3 J c
This is also called Slater’s formula [78, 79]. As a result when the surface of the resonator
is deformed inward in a region where the surface field is predom... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 41 |
20d7fa3e-713b-43df-8fc4-4d85502e80ad | The P = 0.5 triple-spoke-loaded cavity is a complex mechanical system. Simpler
equations are obtained by expressing the deflections and the force density in the basis of
the mechanical eigenmodes, < j > a{x,t), as was done by Karliner, Shapiro, Schulze, and
Delayen [45, 47, 80-82]. Let the inward normal vector on t... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 41 |
dc07ee41-000a-411d-8f70-db2de6266561 | •*=£*■.•«« 2-'*a
The Lagrange equation of motion for the ( X th mechanical mode is:
d
dtdL d K
M a ) dqa dqa
With the assumption, that the mechanical power loss, □, is small relative to the
reactive power. Expanding the potential energy, the kinetic energy, and the power loss in
terms of the generalized coordinates... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 42 |
dcf5c0c0-bc14-4674-bf00-5390148548ea | to the displacement of the cavity wall which, in turn, is proportional to the generalized
coordinate of motion. It follows that:
* ^ ..Aco oc — a 2.24# j j 'la
As a result the total eigenfrequency shift, Ato, can be expressed as the sum of the
frequency shifts due to the contributions of each individual mechanical... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 42 |
e4220f51-1328-423a-bf97-51716585b112 | Substituting 2.24 into equation 2.23 gives:
d r Q . dt c.U
This equation has an important experimental consequence, in that Ato and AtOa can easily
be measured experimentally, whereas the mechanical eigenmodes are extremely difficult
to measure and characterize [45].
2.5 Experimental Methods
2.5.1 Introduction
This ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 43 |
26ef2040-0beb-4640-a99c-d9b2c822c50a | the accelerating gradient.
2) The methodology used to characterize microphonic-noise will be discussed. This
will focus on the hardware and methods used to measure cavity RF frequency
deviation relative to an external oscillator.
3) The methodology used to measure cavity detuning due to the Lorentz force will
be dis... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 43 |
fa2ebf64-32c1-407e-a39c-3d0f3c6e62bc | 2.5.2 The Lumped Parameter Approximation
Circuits can be divided into two classes: circuits which are composed of lumped-
elements, or distributed circuits. Lumped-element circuits combine discrete resistors,
inductors, and capacitors which have dimensions that are much smaller than the
electromagnetic wavelength; w... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 44 |
0390179c-1710-4b46-a722-0cbec0253f1c | distributed cavity resonators can be quantitatively approximated by lumped-element
parallel RLC circuits. This is called the lumped-parameter approximation. Analytically
it is convenient to approximate the distributed circuit with a lumped-parameter model.
Refer to figure 2.6 for a block diagram of the lumped parame... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 44 |
ee8f7589-48f7-4d94-b680-964154fc1a8a | respectively. The power delivered to the resonator is:
,50 £ 2C a v ity
.2C L « C „ 5 0 Q L in e
In p u t C o u p le r1:m
Pick-up C oupler
Figure 2.6: The lumped parameter approximation to a cavity coupled to an
external generator and a pick-up probe.
31
Reproduced with permission of the copyright owner. Further repr... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 44 |
df60349e-a47f-4360-80cd-5100ca29d8d7 | For a fixed cavity voltage the power delivered to the resonator is a minimum when:
61= , 1 r = co 2.29
Va a
As a result, on resonance the stored energy, intrinsic cavity Q, and dissipated power are:
C0-IffC0 = - ° - 1 1 2.300 2
a = - ^ = — 2.3i
® 0 ' ^0 ^^0
\v\ 2Pn — 2.32
2 R o
where A(Oo is the intrinsic bandw... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 45 |
7b0e16e8-d1c2-43c8-a0f6-ab49fdb7a31c | and an input power coupler. This has the effect of damping the overall Q of the system.
The damped Q is referred to as the loaded-cavity Q, Ql. Now the total power required to
operate the cavity (P) is equal to the sum of the power dissipated in the cavity (Pc ), the
power coupled out of the cavity by the pick-up coup... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 45 |
2bdfd56f-1c99-4968-a99e-dfa9b571c01b | Physically, the coupling factor is related to the reflection coefficient, P, for a wave
propagating toward the cavity:
T = ] - P - 2.36
1 + jS
The coupling strength of the pick-up coupler is chosen to be much less than 1, /? « 1, to
avoid damping the intrinsic cavity Q. The pick-up used in the experiments describ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 46 |
fc806de7-9c96-4b23-bc7f-1511dc994580 | varied over the range 2 x 108 < Qext < 3 x 101 0 and the P = 0.5 TSR variable power
coupler Qext could be varied over the range 5 x 106 < < 5 x 109 , these measurements
are accurate to 3%.
Now when the RF power is turned off the RF stored energy will decay in a time
defined as the loaded decay time, tc
Ql = 0 ) tl... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 46 |
94382086-4c6d-459a-9f87-a8465270779e | power at the cavity/coupler interface is the measured power value multiplied (divided) by
the attenuation factor of the transmission lines, input coupler, and dual-directional
coupler. The relative error for the forward and reflected power is given by:
AP\ 2
measured
P\ measured /2.40
where A is the attenuation fac... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 47 |
19b01d0e-abda-46f2-b7e6-54043d532085 | respectively. The relative errors of the Q and accelerating gradient at high field levels are
given by:
(mY fAt/V (a* * '2
• ; +U r J +
/a c/n 2
u2.42
2.43
For the experiments discussed here the relative error is approximately 5% for the Q and
4% for Eacc. No statistical errors are analyzed.
2.5.3 Qo versus Eacc Me... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 47 |
649272c8-1f4d-4d6a-becb-df8e886c2d29 | A gilent 8644B
Sign al Generator
a m f m
Low Frequency
Amplifier
Low P a s s
FilterCirculator
200-5000 W
Amplifier
Limiting
Amplifier Oscilloscope
*
IF
Mixer LO
rf36 0 °Phase
Shifter+25dB
/ ^ \ Limiting
Amplifier
/w (v \ 0-132dB
Step Attenuator
Cavity pick-up
signalL i I fI I ,
P-,rs « g> ? e , :L
Fig... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 48 |
6d43f6cb-7e64-48bc-ac02-94b4ca023114 | with the voltage. To circumvent this error growth the signal amplitudes measured with
the oscilloscope are kept constant with a step attenuator and a limiting amplifier. The
actual signal amplitude is then equal to the product of the calibration value and the
attenuation of the step attenuator.
The cavity Q as a fun... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 48 |
6d81678a-afa2-470c-b441-542d32652061 | — •— 4.5 K Data
— * — 2.0 K Data
No 4.5 K Data
1 E 1 0 - -
»
1 E 9 - -
12 10 4 6 8 0 2
Ea c c (MV/m)
4.5 K Data
4.2 K Data
2.0 K Data 1E10
1 E 9 - -
12 10 6 8 2 4 0
Ea c c (MV/m)
Figure 2.8: Q curves for the P = 0.4 DSR (top) and the P = 0.5 TSR (bottom).
36
Reproduced with permission of the copyright owner. Furt... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 49 |
d20d6fcc-1f67-401a-9fa4-1c952824a3ca | f / t f0
HYBRID
QUAD1
9 0 °
Y(t)XAgilent 8644B
Signal Generator
|Sp/ifter[-
P h a se
Shinerf2(t)
X(t)
+ X(t)m i
dt
Figure 2.9: Block diagram of the cavity resonance monitor. The device used to
experimentally measure the frequency difference between the cavity RF field and an
external stable oscillator.
2.5.4 RF Fr... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 50 |
1675b8ef-2e60-4a0e-833a-89d18a997b4b | signals:
fi t ) = A s\n{o\t + 0l) 2.45
f i t ) = A sm io if + < / > 2) 2.46
First, fi(t) is split into two components with a relative phase difference of 90°, and
/2(f) is split into two in phase components:
fit)= > f° \t) = ^ s m ic o lt + 0l) ■
f i it) => f t it) = - sin(<y2 r + < j > 2)/, it) = ■= = smi... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 50 |
0aadf302-0947-4236-9416-e84184fe01cb | Second, two doubly balanced mixers form the product of two of the split signals and
the mixer outputs are each filtered with a low-pass filter. Generating the signals:
where f o u t(t) is the output of the CRM, the frequency deviation signal, which is
proportional to the frequency difference between the two input si... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 51 |
45bf7bfd-058a-4838-b371-7cfef7913df0 | the results are displayed in figure 2.10. The probability density (histogram) of the
reference oscillator’s phase-noise is graphed on top. The horizontal axis is the RF
frequency deviation signal and the vertical axis is the product of 20 and the logarithm of
the ratio of the number of counts in the histogram bin to... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 51 |
f57317ab-8c5b-471f-8838-27cfbdec490c | dt 162.52
v ,.d X (t) . A 4 2/* , ,.Y(t) — — = A ct)— cos (A<» ■ t + A0)
dt 162.53
f o u i(t) = -A a > ~
102.54
Num ber o f Counts in the Bin
ttcounlsTotal # o f Data Po int s2.55
horizontal axis is the FFT frequency in hertz of the time domain data and the vertical axis
38
Reproduced with permission of the copy... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 51 |
0ce13f87-4678-4b71-a06b-7533814dfcf6 | -2 0 - -
- 4 0 --
| - 6 0 --c t = 0.33 Hz
rm s
C OT J
-8 0 --
-100 - -To LABView
DAQ
S ig 1 S ig 2CRM
A gilent 8644B
S ign al G enerator
R F „
A gilent 8644B
S ign al G enerator
- 1 2 0 - 1 --------- l - 4 - l --------- 1--------- 1--------- 1--------- 1--------- 1--------- 1--------- 1--------- 1--------- 1-... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 52 |
9b0728e3-0005-44bc-a87c-499735a92b8d | is the amplitude of the RF frequency deviation. The axes scales were chosen to coincide
with the scales used in chapters 4 and 5 of this dissertation. Notice that at low FFT
frequencies the output of the HP8644B is stable and the rms frequency deviation of two
reference oscillators is 0.33 Hz.
2.5.4.2 Determination ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 53 |
278d497e-168f-4087-9b2d-35f9536f60c8 | AM FM
To LABView
DAQLow P a s s
FilterLow F req u e n c y
Amplifier[>C irculator
200-5000 W
Amplifier
Limiting
AmplifierOscilloscope
IF
M ixer LO
rf360° P h a s e
Shifter+25dB
Limiting
Amplifier
M v \ 0-132dB
S te p A tte n u a to r
? o r
Limiting
1-3dB '< ■ >
A g ile n t 8644B
S ig n a l G en e r a t... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 53 |
0da4d6e8-4705-48bd-bc75-6f83c466c362 | 2.5.5 Lorentz Transfer Function Measurement
The Lorentz transfer function will be covered in detail in chapter 3. To measure the
Lorentz transfer function sinusoidal modulations of the cavity RF frequency, sinusoidal
modulations of the cavity RF field amplitude, and the relative phase between these
modulations must ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 54 |
3e3bb69e-60f1-45cb-91bb-3c3d19769439 | rfOscilloscope
3 6 0 ° P h a s e
Shifter+25dB
Limiting
Amplifier
a a|w 0-132dB
S te p A tte n u a to r
3dB Splitter
-20dB
Directional
Coupler
____________________ RF A m plitude
D etecto r
Figure 2.12: Block diagram of the Lorentz transfer function measurement, chapter 3.
First, the cavity Qo is typically 109 o... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 54 |
02030437-418b-4f25-9a1f-55465e3ad39a | Finally, the frequency modulation signal is measured with the lock-in amplifier which
measures both the amplitude of the RF frequency modulation and its relative phase to the
forward power modulation. The cavity RF field amplitude is monitored with an RF
amplitude detector which outputs a voltage proportional to the... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 55 |
3e96115a-e5a1-4a4c-a0c5-a915f3f231a3 | frequency modulation (figure 2.13).
2) The mechanical fast tuner is used to damp the microphonic-noise induced RF
frequency variations (figure 2.14).
3) The mechanical fast tuner is used to phase lock the cavity RF field to an external
reference oscillator (figure 2.15).
2.5.6.1 Coupled Fast Tuner/Cavity Transfer Fun... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 55 |
a7a56ef2-3224-4a7e-8a0b-662cc7e10568 | fast mechanical timer. This results in a sinusoidal modulation of the cavity RF
frequency.
3) The cavity RF frequency deviation from an external oscillator is measured with a
CRM. The cavity RF frequency deviation amplitude and phase relative to the
signal driving the fast mechanical tuner are measured with the lock... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 55 |
a81079c4-2fae-4363-ad90-8b42998dd4d1 | Agilent 8644B
Signal Generator
FM RFCirculator
I Low Frequency A Amplifier
Limiting
Amplifier200-5000 W
Amplifier
To LABView
DAQ Oscilloscope
Low Pass+25dB
^ Limiting
Amplifier360° Phase
ShifterM V i 0-132dB
Step Attenuator Stanford R esearch
System s SR830
Lock-In AmplifieiMixer LO
Limiting
Amplifier ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 56 |
af074503-5ec6-4e47-8581-d3f7dadceb17 | Amplifier
Low Pass
FilterA gilent 8644B
S ig n a l G enerator
A M FMTuner Driver
AmplifierR F , ,
Figure 2.14: Negative frequency feedback system for damping RF frequency variations with a
mechanical tuner.
43
Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 56 |
9ce1f163-bb03-4951-a5bf-c46d5045ba4c | 2.5.6.2 Fast Tuner Microphonic-Noise Damping
To damp the microphonic-noise of a spoke-loaded cavity the fast mechanical tuner is
driven by the instantaneous frequency difference between the cavity and the external
oscillator (figure 2.14). These experiments are discussed in chapter 5.
1) An external reference oscill... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 57 |
14918dde-858b-43b7-b2b7-61986657ed49 | Argonne National Laboratory [88]. A block diagram of the experimental layout is shown
in figure 2.15. The phase controller performs two functions.
1) The amplitude of the cavity pick-up signal is measured with an amplitude
detector. The amplitude controller compares the amplitude of the cavity pick-up
signal to a DC... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 57 |
708abea9-9dbc-4a1e-982d-568b8038a141 | Reproduced w ith permission o f th e copyright owner. Further reproduction prohibited without permission.
To LABView
DAQPhase
Controller
A gilent 8644B
S ign al Generator
a m FM
CRM
Difference
Sig 1 Sig 2
r JPhase Error
Signal
Phase
ControllerAmplitudo
Controller
Precision P hase
DetectorX.
f j] Amplitude
DeLe... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 58 |
2cf4fe8f-7f27-4212-9b78-a247ebcdb541 | Chapter 3
Lorentz Force Detuning
3.1 Introduction
Two distinguishable sources of cavity mechanical deformations which couple to the
cavity RF field are microphonics and the Lorentz force [43, 45-47]. This chapter will
present experimental results which characterize the coupling between the electromagnetic
eigenmode ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 59 |
27b99d5c-4729-4017-a34b-de06d11fe31e | detuning in superconducting cavities when the detuning is driven by the Lorentz force.
Chapter 3 is separated into 4 parts.
1) Lorentz force detuning is discussed.
2) The Lorentz transfer function is defined and the experimentally measured Lorentz
transfer function of the (3 = 0.5 TSR is presented.
3) One of the two ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 59 |
a23fbdaa-0add-4aa6-9bc8-83630e638318 | gradient or the precision of the amplitude and phase control in beam-loaded accelerator
cavities is not a new problem. Lorentz detuning was first noticed in a normal-conducting
25 MHz cavity at the Novosibirsk electron-positron storage ring VEPP-2 in 1966 [80,
81]. The loaded bandwidths of the superconducting cavit... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 59 |
f1747741-c509-4133-af1a-d2d79ffee50f | to the beam bunches in the presence of both Lorentz force and microphonic induced RF
frequency variations. At that time, researchers developed tuners and control systems
capable of counteracting the detuning and controlling the RF field phase and amplitude in
the presence of both microphonic and Lorentz force induce... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 60 |
39546cea-46a7-48fb-875e-c3c5bc325afb | peak surface field magnitudes are approximately 30 MV/m and 800 G, which correspond
to pressures of 15 torr and 10 torr respectively. This deforms the cavity wall and shifts
the resonant frequency by hundreds of hertz as the cavity RF field pulses [89].
Another consequence of operating at the gradients necessary to i... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 60 |
ef92a977-6d28-4d41-8abf-e7de67702357 | cavities in order to develop the control systems necessary to control the RF field
amplitude and phase.
3.3 The Lorentz Transfer Function
To characterize the coupling between the cavity RF field and the mechanical
eigenmodes driven by the Lorentz force, a transfer function is experimentally measured.
The transfer fu... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 60 |
baddf1b5-2b33-4b0c-8eca-f51cf768a471 | and the total RF frequency shift of the excited electromagnetic eigenmode is:
A < y = £A6>„ 3.2
a
The electric and magnetic field components of the resonator electromagnetic eigenmodes
are not independent but are related through Maxwell’s equations. Both the magnitude of
the electromagnetic force acting on the cavit... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 61 |
6e1240bb-1ef3-44b3-a29c-e04f8168fef5 | measurable quantity and that it contains all of the physics of the interactions between the
electromagnetic eigenmodes and the mechanical eigenmodes. The Lorentz transfer
function correlates an RF field amplitude modulation with the consequent Lorentz forceSubstituting equations 3.3 and 3.4 into equation 3.1 gives:
... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 61 |
2a34fb2d-2a83-40c7-8a6f-0b9ee400a1b7 | induced RF frequency modulation. Measuring the Lorentz transfer function yields all of
the information necessary to calculate the RF frequency variations due to changes in the
RF field amplitude and this is done without directly characterizing every mechanical
eigenmode of the coupled cavity/cryomodule mechanical sy... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 62 |
5c26980b-0aee-44b5-b423-f1d00fbe35c5 | are input into the oscilloscope allowing for the RF field modulation amplitude, the
resulting frequency modulation, and their relative phase shift to be measured as a
function of the amplitude modulation frequency. This method is use to measure the
Lorentz transfer function at amplitude modulation frequencies within... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 62 |
43ada566-5751-4666-b143-530127ba207e | figure 3.1 [89]. The horizontal axis is the amplitude modulation frequency, referred to as
the vibration frequency. The top half of the plot is the amplitude of the cavity RF
frequency modulation divided by:
AE2=E2 - E 2 . 3.9acc,max acc, mm
where E 2acc>max and E 2acc,min are the maximum and the minimum of the a... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 62 |
bd405312-a89b-42c5-ad0f-b32cf313cba0 | io n o f the copyright ow ner. Further reproduction prohibited without p erm ission.
1000
1 0 0 r rE \ \
52
■ nx
< u■ o
S
3 .
E<10
1 ir
0.1
o o . :
$
g» -45--
o
# -90 - -T Ofo.-135 - -
-180
700 800 900 1000 1100 1200 1300 1400 1500 200 300 400 500 600 0 100
V ibration F re q u e n c y (Hz)
Figure 3.1: The meas... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 63 |
dd9f7ff9-b9e0-4d4c-9ee3-b4060bebe2a8 | 3.4 Pulsed Cavity Detuning
Pulsed operation is characterized by a cyclic rapid excitation of the cavity RF field
using a pulsed RF power source, the rapid excitation of the cavity being followed by a
similarly rapid decay when the power is turned off. In general, pulsed operation offers
two features which may be adv... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 64 |
90a701a7-929e-4a9d-957e-e1d0788e96c1 | fit) = £ * ( f l) • E 2 a c c {Cl) • dQ. 3.10
Hence, the convolution of the Lorentz transfer function and the second power of the
accelerating gradient yield the time-domain response.
The predicted and the measured response to a pulsed cavity field are graphed in figure
3.2 for several different pulse durations an... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 64 |
339e1c95-402b-42c7-a3f6-69ae651db186 | not continuous on the top plot. This was done to show the predicted and measured
response after two uninterrupted pulses.
51
Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 64 |
ed33fc34-11a8-4131-abaf-3aeadcf229db | Reproduced w ith permission o f th e copyright owner. Further reproduction prohibited without permission.
M e a s u re d
P re d ic te d
£ 1 5- -
0 30 50 1 0 2 0 40
T im e (m s) M e a su re d
P re d ic te d
T im e (m s)
M e a s u re d
P re d ic te d
o 30 5 0 1 0 2 0 40
T im e (m s)7 - i s o - .
i io ..
Figure... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 65 |
d8e2b6f7-4f29-41bd-bd9c-4215b8d3cd99 | -1 0 0 - -
Measured
Predicted- 1 5 0 - -
-200
1 6 - -
6--
30 0 1 0 2 0 40 990 1000 1020 1040 1010 1030
Time (ms)
>100-1 — Measured
Predicted
-iso - -
u.
-200
£ 15--
5 - -
1 0 30 80 100 0 2 0 40 50 60 70 90
Time (ms)
Figure 3.3: The RF frequency deviation of the p = 0.5 TSR from an external oscillator due
to rep... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 66 |
3f3a577d-fbd3-44f4-ab5c-ffd471a94d91 | 3.5 Discussion of the Lorentz Transfer Function
Sections 3.3 and 3.4 demonstrated a powerful method for studying and analyzing
dynamic Lorentz detuning in superconducting cavities. It was shown that the Lorentz
transfer function completely characterized the coupling between the cavity RF field and
the Lorentz force ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 67 |
359e498d-501c-436c-92cc-6f7b71dbd1bf | and the P = 0.4 DSR (figure 3.4) offer insights into the mechanical structure of multi
spoke loaded cavities which would otherwise required the characterization of the cavity
mechanical eigenmodes. The Lorentz transfer function of both the P = 0.5 TSR and the P
= 0.4 DSR show that the cavity RF fields do not couple ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 67 |
63782ad8-f17c-453b-b50a-4127576f7ce5 | low-frequency mechanical vibrations and as a result microphonic-noise can drive
mechanical eigenmodes.
Finally, a 5 kW peak pulsed power 345 MHz RF amplifier was available for the
experiments presented in section 3.4. To pulse the p = 0.5 TSR to 10.5 MV/m in 1.5 ms
at 10 Hz, operating parameters for the proposed Fer... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 67 |
f4a75556-c64d-4546-a4af-f1c979206202 | bandwidth. This corresponds to a 25% increase in the RF power required to phase-
stabilize the cavity with overcoupling alone.
54
Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 67 |
06db3084-bf15-4425-a04f-490d6cd0b4da | E
5
2
NXIiplitude
a)TJ3+ ■ *
Q.
E
<1 0 0
Phase-100
200 600 400
V ibration F requency (Hz)800 1000
Figure 3.4: The Lorentz transfer function of a P = 0.4 double-spoke-loaded
cavity.
360
10.0-- -- 315
A m plitude -- 270
< N
-- 225 £55-- 180 N
XI
a >" O3
C L
E<-- 135
-- 90
Phase -- 45
0 120 180 240 300 360 60 420
Vibrati... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 68 |
d0df37b4-38bf-4f0f-a650-7ce9a20b0165 | Accelerating
Beam© .200 - -
100
20-
0 1 2 3 4 5
Time (ms)
Figure 3.6: The (3 = 0.5 TSR Lorentz transfer function prediction for a 1.5 ms 10 Hz
10.5 MV/m pulse train. These are the operating parameters for the FNAL 8 GeV proton driver
linac, one future accelerator which includes spoke-loaded cavities in the proposal... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 69 |
4c29098d-1eba-46b1-9fea-49bc98f8be09 | Chapter 4
Microphonic Induced RF Frequency Variations
4.1 Introduction
This chapter presents the experimental results used to characterize the
microphonic-noise induced RF frequency variations of a P = 0.4 DSR and a P = 0.5 TSR.
The chapter is separated into four parts.
1) A general discussion of continuous-wave oper... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 70 |
1efaf8c3-7449-4828-8c6f-9d69b087e463 | discussed.
4) Chapter 4 will conclude with a discussion of the results.
4.2 Continuous-Wave Operation
The mode of accelerator operation in which the cavity RF field amplitude is constant
is referred to as continuous-wave operation. Continuous-wave operation is often possible
only with superconducting cavities, becaus... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 70 |
9b053217-0646-4feb-b0ad-38da22403e03 | • The peak current in a continuous wave accelerator is typically 1% or less than
found in a pulsed accelerator operating at the same average current [13].
• Smaller peak beam currents result in smaller peak event rates. Hence,
experimental detectors may be made more sensitive and not saturate.
57
Reproduced with permis... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 70 |
72626e2b-8703-4b7e-bb84-7d6f0e8bab56 | • Transient heating of high-power targets is eliminated [94].
• Time-dependent Lorentz detuning of the cavities is not a problem.
It is the subset of cavity RF frequency variations which are a large fraction of the
loaded bandwidth that are a concern for continuous-wave accelerators, referred to as
microphonic-noise ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 71 |
fd37ed82-06c6-4c5b-b8c5-73b6e3952fe1 | the cavity at a fixed gradient in the presence of microphonic-noise [46],
• Determine and eliminate the sources of the microphonic-noise [89].
• Change the mechanical design of the cavity to decrease the coupling
between the cavity RF field and the mechanical vibrations driven by the
microphonics [89, 96, 97]. This i... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 71 |
b13a1bcf-0f76-4773-aa91-2c60b86f65e8 | external pressure by reinforcing the cavity end walls [96, 97], Each of the cavity end
walls was reinforced with 12 support gussets. This reduces the deflection of the rigid end
walls and, hence, reduces the microphonic-noise. The effect of adiabatic pressure
changes on the cavity RF frequency (A/7Ap) was measured t... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 71 |
d43bd668-e63b-4d4b-94ac-6b25fc244bf3 | The P = 0.42 DSR microphonic-noise was measured at 4.2 K and at several cavity
field levels: at 1 MV/m, requiring a 0.3 watt RF input and at 7 MV/m, requiring 16 W of
RF input [95]. The microphonic-noise at both of the input power levels is graphed in
figures 4.1, 4.2, and 4.3.
Figure 4.1 graphs the time-domain mic... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 72 |
3ffce486-74a1-4778-878f-a86ca4f19780 | total# o f observations J
The solid points are the experimental data while the solid lines are the results of a least
-25.16 Wrf 7 MV/m Microphonics (arm s = 5).3 Hz)
0.3 Wrf 1 MV/m Microphonics ( a rmK = 3.1 Hz)
■ I ■ I ' I ■ I i I ■ I ■ I ■ I ■ I ■
10 20 30 70 80 90 100 40 50 60
Time (s)
Figure 4... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 72 |
f5eab576-49cf-45f9-af70-9edd472352dc | 7 MV/m (16 Wrf a =5.3 Hz)' rf rms '
1MV/m(0.3Wrfa =3.1 Hz)' rf rms 1-10
-20
-30
-40
-50
g-60
o f -70
-80
-90
-100
-110
-120
-25 -10 0 15 20 25 -20 -15 -5 5 10
Frequency Deviation (Hz)
Figure 4.2: The probability density of the (5 = 0.42 double-spoke cavity microphonic
induced RF frequency variation with the input p... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 73 |
8bee0478-3f54-41b1-938f-ae622d5d5ec7 | mechanical vibration frequency and the y-axis is the peak cavity RF frequency deviation
amplitude. For reference, a line corresponding to the peak frequency deviation required
to drive a ±0.3° phase precession is added to the graph; ±0.3° is the design goal for the
cavities in the proposed AEBL driver linac [98, 99... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 73 |
d41bed86-b2e1-4abf-b65d-560b3770bc7a | 10 i i i i i i i 1 1 i i i i i i i 1 1 i i i i i i i.
7 MV/m (16 W J a =5.3 Hz' rf' rms
1 MV/m (0.3 W J a =3.1 Hz' rf' rm s
1 10 100 1000
Vibration Frequency (Hz)
Figure 4.3: The vibration spectrum of the P = 0.42 double-spoke cavity microphonic induced RF
frequency variation with the input power = 16 W (Ea c c = 7... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 74 |
c1090b9f-843c-4690-9d37-ab88464b9f40 | were correlated [100], A pressure measurement system with a resolution of 1 mtorr was
installed to measure the vapor pressure of the liquid helium bath. The P = 0.4 DSR RF
frequency deviation from an external stable oscillator and the external pressure deviation
from atmospheric pressure were simultaneously measure... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 74 |
e690c514-9d83-45aa-8509-f48129ac1c27 | Helium Pressure Deviation
Double Spoke Frequency Deviation111111111itV1111Y i
10 ±3
fl-0 .2
10 ^
-10
-20 S'
=--10
■ i r - 2 0
4 5 6Time (sec)
Figure 4.4: The p = 0.42 DSR RF frequency variations plotted as a function of time with the variations of
the helium coolant vapor pressure superimposed. The three plots corr... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 75 |
fd9611da-824d-404c-b3b7-1916bc46e9a1 | Figure 4.5 shows the probability density of the pressure and frequency variations for
the three input power levels. The microphonic-noise probability density is on top and the
external pressure fluctuation probability density is the lower graph. The vertical axes
both follow equation 4.1. The x-axis of the top graph... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 75 |
1ffb16ce-4855-4301-99f1-c127c3241ffa | Figure 4.6 graphs the vibration spectrum of the microphonic-noise and pressure
deviations for the three input power levels. The top graph is the vibration spectrum of
microphonic-noise and the lower graph is the vibration spectrum of the helium vapor
pressure deviation. The x-axis is the Fourier transform frequency ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 76 |
5acae75c-fcb7-4718-8007-29356f45a43f | microphonic vibrations below 5 Hz is very similar to that of the low frequency helium
pressure deviation.
Figure 4.7 shows the cross-correlation between the P = 0.42 DSR RF frequency
variations and the helium vapor pressure for the three input power levels. The cross
correlation at the lag time t between the RF freq... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 76 |
f7f4258a-5a1a-411e-9f3d-5701c94c1241 | The denominator in equation 4.3 was chosen to normalize the cross-correlation
function to ±1. If the cross-correlation function equals 0 there is no correlation between
the data, and if the cross-correlation function equals 1 the data is highly correlated. A
large negative cross-correlation corresponds to a large c... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 76 |
aa09de08-cd7e-4cc1-b0a2-1270c4b05fb7 | This data has two consequences:
• The p = 0.47 DSR RF frequency deviation from a reference oscillator is highly
correlated with changes in the helium vapor pressure.
• The RF power dissipated in the cavity appears to be driving both the variations in
the P = 0.42 RF frequency and the helium vapor pressure.
4.3.3 The ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 77 |
440c9fc4-f4d1-4c9d-9368-616df70ee90f | beam loaded cavity bandwidth is:
Figure 4.3 puts a lower limit on the range of microphonic-noise at 50 Hz (this is a
generous estimate since the design gradient input power = 22 W not 16 W as shown in
this figure). An estimate of the RF power required to overcoupling to the P = 0.4 DSR
and drive the cavity at a fixe... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 77 |
5f9cdd76-66e5-4241-8365-b927bf2f389c | may decrease the cavity thermal conductivity. Alternative options are developed and are
presented in the following sections of chapter 4 and in chapter 5. The following sections
of chapter 4 discuss how design changes, which decouple the cavity RF field from
adiabatic pressure changes, reduce the microphonic-noise o... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 77 |
2d3411af-9ba5-4ef4-aecb-64a409285258 | = 5 W
= 14 W
= 22 W-10--
-20--
-4 0 --
-5 0 --
-60
-30 -20 -10 0 20 10 30
Frequency Deviation (Hz)
= 5 W
= 14 W
= 22 W-10--
-20--
-4 0 --
-50 - -
-60
-0.3 -0.2 0.0 0.2 -0.1 0.1 0.3
Pressure Deviation (torr)
Figure 4.5: The probability density of RF frequency and pressure variations of the P = 0.4 DSR
operating at ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 78 |
503c9448-fdbd-4699-b2da-f6e9c29ccdd2 | 1 10 100
Vibration Frequency (Hz)
10 I i i ----1 i i — i — i i-| ------------ 1------ 1 — i — i—i — i — i i
Vibration Frequency (Hz)
Figure 4.6: The spectrum of RF frequency and pressure variations of the p = 0.4 DSR
operating at input powers equal to 5 W, 14 W, and 22W.
66
Reproduced with permission of the copy... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 79 |
46a9de62-e3d1-42b4-a5a4-494b187ec429 | 1.0
0.5
0.0
-0.5
a
.2-1.0
2 l.O
£ 0.5
3 0.0IM * - £ -0 .5
O-i.o
1.0
0.5= 22 Win
= 14 W
-0.5= 5 Win
-1.0
-10 -8 6 -4 2 0 2 4 6 8 10Lag Time (sec)
Figure 4.7: The cross-correlation functions between the RF frequency variation and the helium vapor
pressure variation of the P = 0.4 DSR operating at input powers equal to... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 80 |
436c359f-0746-4e48-87c6-d74bb47c4497 | of predominantly magnetic surface field with those due to the regions of predominantly
electric surface field. Refer to equation 2.12 for the cavity frequency shift [78, 79]:
jf//|tf(x )|2 - e \ E ( x f ^ i a
------------------------------- 4.5
f Stored Energy
The 3 = 0.5 TSR was constructed with mechanical support ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 80 |
b64d41a5-323b-4287-a4e8-a38873a9be97 | reduce the deformation of the walls due to changes in the helium bath pressure but are not
intended to make the cavity infinitely rigid. Instead the support gussets balance the
magnetic and the electric field contributions to the cavity RF frequency shift.
For a 1 atmosphere pressure increase between the cavity exte... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 81 |
ffd944fc-54d6-4c2f-a065-ff48dab93386 | Initially, several of the reinforcing ribs were intentionally oversized, leaving a
residual A/7Ap of -12.4 Hz/torr; the design guiding the rib placement predicted a shift of -
10.5 Hz/torr. The residual A/7Ap was kept to allow for a fine tuning of A/7Ap by cutting
away sections of the oversized support gussets after ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 81 |
69e2eda6-3571-4308-b11d-81c37c86151a | [52, 89]. The microphonic-noise for input powers of 20 W and 100W are shown in
figures 4.8 and 4.9.
Figure 4.8 graphs both the microphonic-noise in the time domain and the Fourier
transform of the data. There are four separate graphs in this figure. On the left, the time-
domain data is graphed with the horizontal a... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 81 |
a2b9cf35-1efe-4de0-83a2-4a60ae1b7532 | Figure 4.9 graphs the probability density of the cavity RF frequency variations at each
input power level. The horizontal axis is the RF frequency deviation and the vertical axis
follow equation 4.1. Notice two features of these graphs:
1) The rms frequency deviation does not change as the power is increased.
2) The ... | d:\Zotero\sync\storage\ZGQ8M6VR\Conway - 2007 - Electro-Mechanical Interactions in Superconducting Spoke -Loaded Cavities.pdf | 82 |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.