id
stringlengths
36
36
text
stringlengths
1
1k
source
stringlengths
42
191
page
int64
0
1.03k
4a632b09-b91c-429a-ae9b-e4b5cbcfa352
OPTICS MODELLING CHALLENGES FOR THE HL-LHC R. De Maria∗, P. Bestmann, G. Dima, L. Fiscarelli, C. Petrone, V. Rude, K. Skoufaris, European Organization for Nuclear Research, Geneva, Switzerland Abstract The HL-LHC will operate with very low 𝛽∗and tight alignment constraints around the upgraded ATLAS and CMS experiments...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
0
fa1144b7-6774-4110-85db-7d2feaf27369
tionsandquadrupolefringefieldsinopticsmodels,andtheir expectedimpactonresidualorbiterrorandoptics-correction convergence speed during commissioning. INTRODUCTION HL-LHC optics around the interaction regions at the end ofluminositylevelinghavelarge 𝛽-functionstoproducea very smallbeam spot atthe interaction point. Then...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
0
357ba990-c16d-4b0a-a8fd-362aa689ca0b
ing an as-built operational model in Run 4 instead of a nom- inal one1and discusses the expected advantages. MAGNETIC AXIS DEVIATIONS Deviationsofthemagneticaxisgenerate1)unwantedorbit errors proportional to the transverse offsets of the magnetic axis(thepositionatwhichthemagneticfieldiszero)rela- tive to the ideal mac...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
0
2df1ee4e-bd01-4109-9d85-39f568824869
thattransverseoffsetscanbeupto 0.5mmandrolloffsets below1mrad. Orbit correctors can compensate for offset deviationstotheextentthattheerrorsarebelow 0.5mm[8]. ∗riccardo.de.maria@cern.ch 1Inthe past,magnetic measurements could not be reconciled with optics measurements[ 6] Figure 1: Expected magnetic-axis misalignment i...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
0
f5b5f0f7-c62b-4109-bc12-114cb1740496
andglobalcouplingcorrectors;however,relyingonglobal correctorsimplieseitherhavingcouplingattheIP,whichre- ducesluminosity,orcouplinginthetriplets,whichenhances nonlinearcouplingeffects. Inaddition,startingcommission- ingwithstrongcouplinginevitablyincreasescommissioning time. Given these premises, the best strategy is ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
0
639707cf-de08-4940-9646-38082a128d0d
theslopes,wouldresultinexcessiveoffsetsinthebellows. Acompromisesolution[ 12],compensatingonlyfortheaver- age axis correction, shows almost negligible orbit error and orbit-corrector usage while preserving the bellows range. Measured roll deviations reached 2.5mrad[7]. Uncom- pensated, they wouldrequireabout half the a...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
0
58b4335d-9185-49ae-9010-ecccf6f2372d
Figure 2: Expected trajectory and orbit-corrector powering in the IT string before (top) and after correction (bottom). Orange bars show corrector kicks in percent of available strength, using the right axis; grey boxes show the triplet- gradient locations. Figure3: Fringe-fieldapproximationusedforopticscalcu- lation. ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
1
ba48927e-c74f-496a-b1a9-a69e307d912b
is used in the following estimates; b) Magnetic-length devi- ationscanbeestimatedfromthemeasurementsofthefirst quadrupoles; see Fig. 4and Table 1. The values show a relativespread of about 6⋅10−4forboth magnet types and a systematically longer length for the MQXFB. c) Transfer- functiondeviationscanbeestimatedfromtheme...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
1
c7b77e1e-0b6c-4883-86a4-97efd6066c23
Gradient [T/m] 132.6 133.1+0.2 −0.3 Gradient slope [mT/(Am)] 8.17 7.59+0.01 −0.02 Int. gradient [T] 558.6 560.9+0.8 −1.3 Int. gradient slope [mT/A] 34.4 32.98+0.06 −0.08 MQXB Nominal Measurement Magnetic length [m] 7.172 7.179+0.005 −0.003 Gradient [T/m] 132.6 132.5+0.2 −0.2 Gradient slope [mT/(Am)] 8.17 7.55+0.03 −0.0...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
1
d13976cc-afc0-4987-9c98-e849ca5bd564
unstable optics. Imperfection a [%] b [%] c [%] Fringe fields 17 0.01 0.005 Magnetic length systematic 28 0.04 0.017 Magnetic length spread 2 0.01 0.007 Transfer-function spread unst. 0.12 0.12 Longitudinal misalignment 8 0.004 0.005 smaller relative deviation of 17 ⋅ 10−4when considering the integrated field. d) Longi...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
1
03e9b479-f4c6-44ae-b1fc-4c2f7271648f
Atthesametime,thetripletmagnetsandQ4haveenough degrees of freedom to restore the nominal optics trans- port between the IP and Q4. If we include the Q1A trim, which today is limited to performing k-modulation mea- surements [ 16], the triplet system has enough degrees of freedom to restore the optics transport within t...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
1
63c1d805-b637-442e-8305-3809df90c74f
Figure 4: Magnetic-length measurements for the MQXFA and MQXFB magnets as a function of current. Nominal values are used in nominal optics models. Figure5: Transfer-functionmeasurementsoftheMQXFA and MQXFB magnets: deviation between the integrated 𝐵2 componentmeasuredatthereferenceradiusof 50mmand the nominal linear f...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
2
a4feacde-6653-4ee3-9406-8f0c400a3f50
theshorterthetimeitwilltaketoconvergetothenominal optics [18]. It is interesting to compare the uncorrected and fully cor- rected optics errors for the different imperfections men- tioned above to understand their relative importance, as summarisedin Table 2. Thetransfer-functionspread isthe dominantimperfection,follow...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
2
6629ab9d-305e-4800-8898-91288b855d48
expectedmeasurementerrors. ThethirdcolumnshowstheerrorattheIPifthenominalmodelistakenasareference forcorrection. Theseerrorsarealsoverysmallandaccept- able for any correction strategy. The implication is that a well-correctedmachinewillhavenosignificantbeta-beating residualseitherattheIPorinthetripletregion,evenifthe n...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
2
556b7383-9d87-47a5-be77-b2cd071bc5fd
tionsisessentialtopre-alignthemagneticaxisandenable commissioning with a well-corrected orbit and coupling. Theuncertaintyonthemagnetic-axisdeviationsshouldbe well below the deviations observed in the initial production. An uncompensated installation wouldlikelyrequirecorrec- tor strengths beyond the acceptable limits....
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
2
e33ae597-b679-4405-805c-038358d10bea
cludes the imperfections that would otherwise need to be corrected; however, this is not sufficient to eliminate the need for corrections given the observed sensitivity to devia- tionsandtheuncertaintiesinthemagneticmeasurements(in particular,onthetransferfunction). Oncetheidealcorrec- tionisperformed, therealisticmode...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
2
910ff7d7-3c05-4358-ba8b-82edb68e0896
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP1015 90 MC1.A01: Hadron CollidersMOP1015 Monday: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, publi...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
2
33884092-f5e0-44d4-a171-e58658e1d505
REFERENCES [1]S.Fartoukh,F.Cerutti,M.Hostettler,andS.Kostoglou,“LHC machineconfigurationevolutionoverRun3formaximised performanceandinnertripletlifetime”,presentedatIPAC’26, Deauville,France,May2026,paperMOP1057,thisconfer- ence, [2]J.Gray,K.Skoufaris,R.D.Maria,R.Tomas,andY.Angelis, “Design challenges and solutions for...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
3
dfeb3505-c9d9-4436-b7f4-934539418728
this conference, [5]“High-Luminosity Large Hadron Collider (HL-LHC): Tech- nical Design Report V. 0.1”, CERN, CERN-2017-007-M, 2017. doi:1/zero.alt4.23731/CYRM-2/zero.alt417-/zero.alt4/zero.alt44 [6]T. Persson et al., “LHC optics commissioning: a journey towards1%opticscontrol”, Phys.Rev.Accel.Beams ,vol.20, no. 6, p. ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
3
28a213ed-5127-4c99-bbd2-1277309961d7
[9]M. Domínguez et al., “Field quality of the series of short orbit nested corrector magnets for hl-lhc”, IEEE Trans. Appl. Supercond. , vol. 36, no. 3, pp. 1–5, 2026. doi:1/zero.alt4.11/zero.alt49/TASC.2/zero.alt425.3624733[10]V.Ilardietal.,“Fabricationandtestofthefourthprototype of the d2 orbit corrector dipole for h...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
3
ccb2d42e-4adc-48c1-84b8-6ad526329142
//indico.cern.ch/event/1525688/contributions/ 6418/zero.alt474/ , [13]S.I.Bermudez,“Roxie3Dfieldmap”,Privatecommunica- tion, 2012, [14]B. J. Holzer et al., “Study of the Impact of Fringe Fields of the Large Aperture Triplets on the Linear Optics of the HL-LHC”, in Proc. IPAC’13 , Shanghai, China, May 2013, paperWEPEA05...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
3
61a8a9fd-80c4-4c0f-8896-bbe68bbeebba
doi:1/zero.alt4.11/zero.alt43/PhysRevAccelBeams.2/zero.alt4./zero.alt4548/zero.alt41 [17]J.CoellodePortugal,R.Tomás,andM.Hofer,“Newlocal optics measurements and correction techniques for the lhc anditsluminosityupgrade”, Phys.Rev.Accel.Beams ,vol.23, no. 4, p. 041001, Apr. 2020. doi:1/zero.alt4.11/zero.alt43/PhysRevAcc...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1015.pdf
3
54ecc770-b2ef-4ec8-bde1-256061fab20a
SIMULATIONS AND MEASUREMENTS OF INJECTION BACKGROUNDS AT SuperKEKB∗ G. Nigrelli1,2,3†, M. Boscolo2, G. Broggi3, R. Bruce3, Y. Funakoshi4, N. Iida4, H. Kaji4, H. Koiso4, M. Li5,6, Q. Liu7, H. Nakayama4, T. Nemoto8, Y. Ohnishi4, K. Oide3, S. Redaelli3, J. P. T. Salvesen3, T. Mori4 1Sapienza Univ. Rome, Italy,2INFN-LNF, F...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
0
afde73aa-c1fe-41ea-8487-9f0a9b0c89fe
duringdatatakingthatreducethedetectorefficiency. Toim- provetheunderstandingoftheseissues,theinjectionprocess at SuperKEKB has been simulated using the Xsuite simula- tionframework,includingdetailedmulti-turntrackingand particle-matterinteractionsinthecollimators. Theresults ofthese simulations havebeen usedas inputfor...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
0
4a4e2324-9df3-4c82-9829-147b9b6209e0
positronLowEnergyRing(LER)anda7GeVelectronHigh EnergyRing(HER)[ 1–3]. Itdelivershigh-luminositycol- lisions to the Belle II experiment for precision studies of 𝐵-meson decays and searches for physics beyond the stan- dardmodel[ 4]. Theacceleratorcomplexalsoincludesan injector linac and a positron damping ring. Due to ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
0
d9664b49-33af-4955-8862-a92b8db6f5bc
increases with beam intensity, understanding and mitigating these losses is essential for future luminosity improvements. ∗Workpartiallyfunded bythe EAJADEproject. †giulia.nigrelli@cern.ch Figure 1: SuperKEKB collider layout with collimator loca- tion as of 2025. Courtesy of T.Ishibashi and S. Terui. Thispaperpresentsa...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
0
bf5deae1-227d-46b5-b267-546726cb6772
outusingtheXcollmodule[ 10],includingdetailedaperture models and loss localization identification. Beam–matter interactions within the collimators weresimulated through theXsuite-BDSIMcoupling[ 11,12]. Thisworkprovidesan importantbenchmarkofthenewtools. ThefullSuperKEKB lattice2025cwasconvertedfromSADtoXsuiteusingthe S...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
0
2928c473-de1e-4c96-ade8-77afb61af824
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP1016 92 MC1.A02: Lepton Circular CollidersMOP1016 Monday: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the wo...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
0
c1dba065-51bd-4c67-9085-9185b5e17294
tracked over multiple turns. The outputs are spatial and temporal loss distributions along the ring and at the colli- mators. Particles lost within ±4mof the interaction point werethenusedasinputtotheBelleIIdetectorsimulation framework,namelybasf2[ 16],aGeant4-basedenvironment with detailed IR and detector geometry. ME...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
1
61d85f49-70a3-4bc3-ba69-53e7d1de56c0
upwardtoscanthebottomjawandthendownwardtoscan the top jaw. The alignment was performed on two LER ver- tical collimators, D02V1 and D03V4 (see Fig. 1), using a detunedopticsconfiguration with 𝛽∗𝑦= 8mm. Toenhance thelifetimevariation,anorbitbumpwasappliedatthecolli- mator location. The beam current was maintained at 3...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
1
4e4690d6-2e1c-4da3-bc60-dac6fdf66fcb
performed,resultinginasystematicscanofinjectionback- grounds, as shown in Fig. 2. Injection background was monitoredusingtheBelle IIdiamonddetector system[ 18], consisting of 28 detectors installed around the beam pipe in the IR to measure radiation dose rates. A subset of these detectorswasinstrumentedwithanoscillosco...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
1
97e15c54-a3ab-4788-a1c0-62d8b305e004
These two independent observables provide complemen- tary information and are used forquantitativecomparison with simulations. ANALYSIS The analysis was performed using only the D02V1 align- ment scan data, as the CLAWS detectors were not operating reliably during the D03V4 alignment. Only the bottom-jaw scan was consi...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
1
a818c193-3474-4261-96b9-6bdda142067e
afterwards. Theresultingparticlelossesalongtheringwere used to construct observables comparable to the measure- ments. For both measured observables, an uncertainty of ±8𝜇𝑚onthejawpositionwasconsidered,originatingfrom the jaw offset estimated during the alignment procedure. CLAWS Data For comparison with the CLAWS de...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
1
309b45c5-8191-4d9c-9a7d-35f790feb798
ments corresponding to identical collimator offsets were averaged, and uncertainties were taken as the standard devi- ation of the mean. Since no calibration factor is available to correlate the CLAWS signal into lost positrons on the collimator,simulatedandmeasureddatasetswerecompared after normalization to their resp...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
1
7b522fe4-08a3-45ed-9b5e-3c573aacc22c
be2.75×104mRad/sand signals below the threshold were discarded. Measurements at identical offsets were averaged17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP1016 MC1.A02: Lepton Circular Colliders 93Monday: ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
1
ac0003e3-4d0a-4f56-8f29-d3244e8e9128
Figure3: Comparisonbetweennormalizedsimulatedlosses at D02V1 and normalized CLAWS measurements as a func- tion of the bottom jaw offset with respect to initial position. anduncertaintiesassignedasthestandarddeviationofthe mean. Although an absolute comparison is in principle pos- sible,simulateddoseratesareapproximatel...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
2
77ac0ac8-7a83-4379-9e75-8e0c74d334f2
thenormalizedlossesatthecollimatorandondetectorback- grounds as a function of the collimator position. Figure 3 shows the comparison between the normalized simulated losses at D02V1 and the normalized CLAWS signal mea- suredatthesamelocation. ThelossrateatD02V1increases as the bottom jaw approaches the beam orbit. Simu...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
2
c7e80c1d-c7a4-4729-9f59-57a43362d5ee
used during the alignment, which results in a reduced injec- tion background and consequently less clean measurements. Furthermore, even in simulation, only 1%of the particles lost in the IR produce a hit in the detector. Nevertheless, Figure4: Comparisonbetweennormalizedsimulateddose rates at QCS-FW-225 and normalized...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
2
f854ea0f-0f89-485a-ab5e-9f2e7375b596
dominantroleininterceptinginjection-inducedbackground, in agreement with simulations. CONCLUSION Injection-inducedbackgroundsrepresentasignificantlim- itation to achievable luminosity at SuperKEKB due to their impact on detector performance. In this work, a detailed simulationchainbasedonXsuitewasdevelopedtomodel injec...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
2
1adceafe-b68b-4d9a-bee6-0d9048858cba
measures confirms the capability of the simulation chain to describebothlocalinjectionlossesandinjectionbackground far from the beam loss source in the Belle II detector. Future work will focus on improving the model and opti- mizingcollimatorsettingstofurtherreducedetectorback- grounds during injection.17th Internatio...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
2
9dab6944-9596-484c-80cc-51f6c724ef69
REFERENCES [1]K.Akai,K.Furukawa,andH.Koiso,“SuperKEKBCollider”, Nucl. Instrum. Methods Phys. Res. A , vol. 907, pp. 188–199, 2018. doi:1/zero.alt4.1/zero.alt416/j.nima.2/zero.alt418./zero.alt48./zero.alt417 [2]Y.Ohnishi etal.,“AcceleratorDesignatSuperKEKB”, Prog. Theor. Exp. Phys. , vol. 2013, no. 3, p. 03A011, 2013. d...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
3
695dcc09-e09c-4e31-9cde-5406c505bd8f
II in 2020”, in Proc. IPAC’21 , Campinas, Brazil, May 2021, pp. 2532–2535. doi:1/zero.alt4.18429/JACoW-IPAC2/zero.alt421-WEXA/zero.alt47 [7]N.Iidaetal.,“BeaminjectionissuesatSuperKEKB”,in Proc. IPAC’23, Venice, Italy, May 2023, pp. 832–835. doi:1/zero.alt4.18429/JACoW-IPAC2/zero.alt423-MOPL12/zero.alt4 [8]SAD Home Page...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
3
39eabd91-39d7-4d9d-82fb-d5fdc73229a7
J. Instrum. , vol. 19, p. T02004, 2024. doi:1/zero.alt4.1/zero.alt488/1748-/zero.alt4221/19//zero.alt42/T/zero.alt42/zero.alt4/zero.alt44 [12]L.J.Nevay etal.,“BDSIM:AnAcceleratorTrackingCode with Particle-Matter Interactions”, Comput. Phys. Commun. , vol.252, 2020. doi:1/zero.alt4.1/zero.alt416/j.cpc.2/zero.alt42/zero....
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
3
c4d0e27a-7dbb-47eb-a758-6af84042f879
doi:1/zero.alt4.1/zero.alt488/1748-/zero.alt4221/19//zero.alt42/T/zero.alt42/zero.alt4/zero.alt43 [16]T. Kuhr, C. Pulvermacher, M. Ritter, T. Hauth, and N. Braun, “TheBelleIICoreSoftware”, Comput.Softw.BigSci. ,vol.3, no. 1, 2018. doi:1/zero.alt4.1/zero.alt4/zero.alt47/s41781-/zero.alt418-/zero.alt4/zero.alt417-9 [17]T...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
3
4b7b1020-e563-4422-b621-f688851d62e7
[19]K. Yoshihara et al., “Development and implementation of advancedbeamdiagnosticandabortsystemsinSuperKEKB”, Nucl.Instrum.MethodsPhys.Res.A ,vol.1072,p.170117, 2025. doi:1/zero.alt4.1/zero.alt416/j.nima.2/zero.alt424.17/zero.alt411717th International Particle Accelerator Conference, Deauville, France JACoW Publishing...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1016.pdf
3
dc852631-b6e9-4f20-844d-fcdf543b01a2
LHC MAGNETIC MODEL REVISITED: BEAM-BASEDMEASUREMENTS AND MACHINE REPRODUCIBILITY AT INJECTION J. Wańczyk∗, J. F. Esteban Müller, L. Fiscarelli, M. Hostettler, D. Jacquet, M. Solfaroli Camillocci, G. Trad, J. Wenninger, European Organization for Nuclear Research, Geneva, Switzerland Abstract TheharmoniccomponentsoftheLH...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
0
8d572541-92c2-4d2c-acbb-4cd8aea40081
LHC run are used to update the FiDeL tune decay model parameters at 450GeV. The fill-to-fill reproducibility of the machineat injectionisassessedthroughthe distributionof residual manual tune and chromaticity corrections, which yield𝜎𝑄= 0.003–0.004tune units and 𝜎𝑄′= 2.0–2.7 chromaticity units respectively. For fil...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
0
2a624005-793a-4756-b86f-970a6f6d1994
ticdriftsofthemagnetic-fieldmultipolesduringtheinjection plateau. Thisfielddecayaffectstheallowedmultipoles,such asthesextupolecomponent(b3)inthedipoles,whichdrives chromaticitychanges,andthemaincomponent(b2)inthe quadrupoles, which drives tune changes. The phenomenon hasbeena knownoperationalchallengesinceits discover...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
0
fce6604d-9761-4265-8c12-284e4b12cdc8
constants of 200–300s, beam-based measurements revealed timeconstantsof1000–4000sandtunedecayof ∼0.04units, far exceeding pre-operational expectations [ 4]. Since 2011, dynamic corrections for tune and chromatic- itydecayhavebeen applied operationallyusing beam-based parameters;themostrecentupdate priorto the2025runis ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
0
fda271e3-6fba-44ba-bcb3-8221a6fa2232
correction term 𝐻FB(𝑡FB)for the tune. Full details of the analysis are reported in [ 5]. UPDATED DECAY MODEL PARAMETERS The FiDeL tune decay model parameters — decay am- plitude𝛿𝑄, mixing factor 𝑑, and time constant 𝜏— were updated from dedicated beam measurements performed dur- ing 2025 commissioning at 450GeV, ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
0
c90552f6-5a6c-4153-b413-f4be7272c890
were performed simultaneously on all available fills. Figure1: Fill-to-fillnon-reproducibilityofthetunedecayon theinjectionplateauforfivePREfills. Threecommissioning fills (pink) and two April 2025 fills (red, blue); grey line shows the simultaneous fit to all five. For precycle fills, a free simultaneous fit to all fi...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
0
51803a06-5a2a-449f-870e-150945592cc2
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP1019 96 MC1.A01: Hadron CollidersMOP1019 Monday: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, publi...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
0
9751f2c5-11fa-4ce2-b5aa-b7a85a386b72
the large parameter space of the powering history makes systematic sampling impractical within a single commis- sioning period. To guard against a large parameter shift driven by limited statistics, the adopted model is taken as theaverageofthenewfreefitandtheRun2baseline. The horizontal-plane flat-top history scaling ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
1
833f04e3-80ec-473f-be4a-91c9e57a64a7
chromaticity model parameters are carried over from Run 2 unchanged. MACHINE REPRODUCIBILITY AND CORRELATION ANALYSIS Thewidthofthemanualcorrectiondistributionsprovides a direct measure of fill-to-fill machine reproducibility at injection: anarrowerdistributionindicatesthattheFiDeL feed-forwardmoreaccuratelypre-compens...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
1
c456da9a-1ced-4cbf-b47c-89148d1b84ec
allplanes( 𝜎 = 2.0–2.7units),withaflat-topoffsetwhose sign is opposite in the horizontal and vertical planes, con- sistentwithpartialbutimperfectabsorptionoftheflat-top history in the chromaticity model. A dedicated update of the chromaticity 𝐻FTscaling from beam measurements is recommended for a future run. Table1: ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
1
5549ef19-f43e-4930-ab7b-058aadefe1bc
Pearson correlation coefficients between the residual correc- tions (after subtracting the precycle fill median per plane) andasetofcandidatevariableswerecomputedseparatelyfor precycleandflat-topfillsub-samples. Twovariablesshow statistically significant correlations with the tune correction in flat-top fills. Flat-bot...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
1
deb38f02-4051-459c-a8f7-f81a5678f565
significant correlation in the vertical planes, with individual arcs reaching 𝑟 ≈ 0.56 for B2V. The correction spread is also larger at lower bath temperatures. This correlation is identified as a candidate for future model improvement but is not yet incorporated operationally. For precycle fills, no variable reaches ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
1
5c5c8c4f-30be-4a9e-a610-c740cc4550ad
erational model. The correction follows the functional form ofΔPHin [3], normalised at a fixed reference time 𝑡FB,ref= 600s chosen to match the typical flat-bottom dura- tionof precyclefills. However,since thedata donot neces- sarily cross unity at this reference point, an additional scale parameter 𝛿2is introduced, ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
1
b97dd74e-2425-4a2e-b12a-c8b49f0ec532
anchor points added at short and long 𝑡FBto stabilise the extrapolation. Fittedparameters are listedin Table 2. Atthetypicalflat-topfillflat-bottomdurationof ∼800s, the𝐻FBfactor is 0.99–1.01 in the horizontal planes and17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
1
9311ea55-ff34-4cea-9d76-15d3e76cc256
Figure2: Manualtunecorrectionsofall2025nominalphysicsfillsvs.flat-bottomduration 𝑡FBforallfourbeam-planes (precycle fills: blue, flat-top fills: orange). Dashed lines: per-category median with shaded 1𝜎bands. Pearson 𝑟and𝑝 annotated per panel. Table2: Best-fit 𝐻FBparameters(Eq. 1)withfixedreference 𝑡FB,ref= 600s....
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
2
21ec01ca-096b-4bc7-9cb0-759a6a396a42
fillsof3–5×10−3tuneunits,confirmingthat 𝑡FBaccounts for a significant fraction of that shift. Applying the correction significantly reduces the residual dependence: the Pearson |𝑟|drops below 0.2 for all beam- planes(from > 0.5beforecorrection). Aresidualcorrelation remains, reflecting the limitation of the fixed ref...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
2
31295e6b-ce4d-4abd-a672-bc9d59ee776d
icated 2025 beam measurements. Analysis of manual cor- rection distributions from the 2025 physics run quantifies Figure 3: Distributions of manual tune corrections for all nominal physics 2025 fills for the example of B1H. Orange: originalFTcorrections;green: residualsafterapplying 𝐻FB. fill-to-fill reproducibility a...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
2
d80c0b1f-82a4-4adc-8bc0-275981122f46
and arc average helium bath temperature (up to 𝑟 ≈ 0.56) is identifiedandrecommendedforfurtherinvestigation. For precycle fills the source of residual scatter remains unidenti- fied;onepossibleexplanationisthattheprecycle,performed atreducedcurrent,doesnotfullyerasethemagnetpowering history,leavingresidualeffectsnotca...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
2
c79d1bb0-5a9a-4d94-a13a-14bc59f0e36d
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP1019 98 MC1.A01: Hadron CollidersMOP1019 Monday: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, publi...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
2
7e78c4d7-a38f-4e4d-9f7d-3f7f26398247
magnets,” Phys. Rev. Spec. Top. Accel. Beams , vol. 9, no. 1, Jan. 2006, doi:1/zero.alt4.11/zero.alt43/physrevstab.9./zero.alt4124/zero.alt42 . [3]M. Solfaroli Camillocci et al., “Feed-Forward Corrections for Tune and Chromaticity Injection Decay During 2015 LHC Operation,” in Proc. IPAC’16 , Busan, Korea, May 2016, pp...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
3
a5ef1e1e-37ec-445e-b8a0-5b728bb81cdb
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP1019 MC1.A01: Hadron Colliders 99Monday: Poster session MOP1019 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, publi...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1019.pdf
3
e5ebaec4-f7c9-4acc-919f-e95457fb16ed
STUDY OF THE IMPACT OF BFPP LOSSES IN THE LHCb INSERTION R. Calà∗, R. Bruce, R. Cai, F. Cerutti, CERN, Geneva, Switzerland Abstract Besidesitsproton–protonphysicsprogramme,theLHC operates with208Pb82+ion beams colliding in its four exper- iments. At the interaction point, bound-free pair production (BFPP), occurring wh...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
0
60f1fe93-d676-45bc-8034-1ef4bb602014
ingmagnets, and theATLAS andCMS ones,where BFPP lossescanbedisplacedbyanorbitbumpintoanemptycryo- stat, the LHCb insertion optics only allows for orbit bumps broadeningtheBFPPlossdistribution,soastoreducethe peak power load on the concerned magnets. This study investigates the resulting power density in the magnet coil...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
0
0c18c0bb-1642-4950-b015-fc354a3f2968
experiments[2]. Furtherheavy-ionrunsarescheduledfor 2026andareexpectedtocontinuefromRun-4onwards[3,4]. Although beam intensity and luminosity are considerably lower than in proton-proton runs, heavy-ion operation intro- duces unique machine protection challenges arising from specific interaction processes. A concern of...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
0
67ce59a4-9051-4398-be8e-c3c9d2e9ab1d
rise to a narrow secondary beam, whose orbit exceeds the mechanicalapertureinthedispersionsuppressor(DS)ofthe ∗roberto.cala’@cern.ch Figure1: HorizontaltrajectoryoftheBFPPsecondarybeam ontherightsideofLHCbinthe2025configuration,com- puted with (red envelope) and without (orange envelope) a horizontal orbit bump. The ho...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
0
cc389078-678e-4ac9-9328-5cd214a84654
the BFPP beam impact from a superconducting dipole to an empty connection cryostat by means of a horizontal orbit bump around the impact location [6,9,11]. In contrast, the solution for ALICE involved the installation of a DS collimator (TCLD) in the connection cryostat to intercept theBFPPlossesdeflectedbyahorizontalo...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
0
a04c561c-e6fb-4322-b5d4-906ba4b58cc8
powerdeposition. Theeffectivenessofthismeasurewaspre- liminarily investigated at 6.37 𝑍TeV for various transverse emittances by meansof a combinedSixTrack andFLUKA simulations [12]. The present work focuses on the study of the orbit bump actually deployed in IR8 for the 2023–2025 Pb-Pb runs and is based on the combine...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
0
49966198-abd3-4ced-8021-297442c55775
Figure 2: FLUKA model of the LHC IR8 DS region impacted by BFPP losses (top view). SIMULATION FRAMEWORK Thetrackingof208Pb81+ionsfromtheInteractionPoint8 (IP8) to either IR8 side (left and right) was performed using Xsuite,amultiplatformPythontoolkitforbeamdynamics simulations[13]. Toaccountforthepresenceofthebound ele...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
1
69a590c6-728c-4f49-bcd5-2c591e7f567f
MB.C12L8.B2, whose center is located at 490.1 m and -467.7 m from IP8, respectively). The three momentum components and two spatial transverse coordinates of the 208Pb81+ionswererecordedattheIP-sideentranceofthis dipoleandusedasinputforFLUKA,amulti-purposeMonte Carloparticlesimulationpackage[14 –19]. Thesecondstage oft...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
1
981ceeea-2b6b-4ff3-8a02-1c9409c6dec2
length of 14.3 m. The variation of the machine configu- Figure3: SimulatedBFPPlossdistributionontheleftside of LHCb for different operational years as a function of the distance from IP8. The irregular shape of the curves, which are normalized to one secondary ion, is due to the approximationofthetoroidalshapeofthebeam...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
1
ec603720-22da-43a3-9150-1299a38856d8
dump if pre-defined safety limits are exceeded. An accurate BLM model has been implemented in FLUKA and repli- cated in the LHC geometry model according to the actual BLMlayout,soastocalculatethedosedepositedwithinthe17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-9545...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
1
ca7eda23-b078-4019-8806-d31d4d7c9259
425 450 475 500 525 550 575 |s| [m]104 103 102 101 100101102103Dose [Gy] B1 (right) - BLM data 2023 B1 (right) - FLUKA 2023 optics B2 (left) - BLM data 2023 B2 (left) - FLUKA 2023 opticsFigure 4: Measured and simulated BLM dose patterns in half-cells 11to 13 on bothsides of IR8. Measured data are integratedovertheent...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
2
7e8a1377-3f62-45b8-9e40-5142c965da68
of the particle shower they induce. Figure 4 displays the absolutecomparisonbetweensimulatedandmeasuredBLM signalsforthe2023Pb-Pbrun. Whileanexcellentagreement (within20%forallconcernedBLMs)isachievedontheleft sideofIR8, anunderestimationupto afactorof4 isfound ontherightside. Inviewoftheconsistencyofthegeometry modeli...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
2
59f93cf4-786a-4ac1-ab0f-b288581605ee
main dipole and the following main quadrupole in half-cell 12ontheleftofIR8. Thecurvesnaturallyreflectthedifferent impactpatternsofFig.3, dependingontheoperationalyear, anddonotexceed5mW/cm3attheinstantaneousluminosity deployed by leveling in LHCb during the 2025 Pb-Pb run. The latter value offers a sizeable margin wit...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
2
e4551087-91bd-44a7-a53b-5c0467b8f790
raise of the LHCb luminosity threshold. 480.0 477.5 475.0 472.5 470.0 467.5 465.0 462.5 460.0 Distance from IP8 [m]012345Peak power density [mW / cm3] MB.C12L8 MQ.12L8 BFPP B2 - 2023 BFPP B2 - 2024 BFPP B2 - 2025Figure 5: FLUKA-simulated longitudinal profile of radially- averagedpeakpowerdensityinthecoilsoftheM...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
2
8646e55d-e53e-46e0-8f53-a1a24ea98018
implemented in IR8, so as to spread out BFPP losses while shiftingtheirimpactfromhalf-cell10to12. Thisallowed forlevelingat 1.5×1027cm−2s−1inLHCbduringthe2025 run. A detailed study was conducted for both sides of IR8 us- ingthedifferentionopticsimplementedduringRun-3. This work used both Xsuite and FLUKA, for tracking2...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
2
8a425c7e-fc90-407f-ac14-1a6bbc329b0f
expected quench limit. If the BLM underestimation, where occurring,istheresultofanunpredicteddisplacementofthe impactdistributionandtheactualspreadofthelatterdoes not get markedly reduced, a non-negligible margin for an instantaneous luminosity increase would be available. This calls for pursuing further investigations...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
2
33f62b84-350c-49e9-acfd-aacb6ac3c9cb
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP1020 102 MC1.A01: Hadron CollidersMOP1020 Monday: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, publ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
2
efc4a6b7-5a10-4272-a0da-4a3ae12a1956
[3]R.Bruceet al.,“HL-LHCoperationalscenarioforPb-Pband p-Pb operation”, CERN Report No. CERN-ACC-2020-0011, 2020.https://cds.cern.ch/record/2722753 [4]R. Bruceet al., “Performance and luminosity models for heavy-ion operation at the CERN Large Hadron Collider”, Eur. Phys. J. Plus, vol. 136, p. 745, 2021. doi:10.1140/ep...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
3
b4e05206-f2d1-44c2-9f78-640f241c660f
and nuclear excitation in heavy ion colliders”,Nucl. Instrum. Methods Phys. Res. A, vol. 459, pp. 51–57, 2001. doi:10.1016/S0168-9002(00)00995-5 [8]R.Bruceet al.,“ObservationsofBeamLossesDuetoBound- Free Pair Production in a Heavy-Ion Collider”,Phys. Rev. Lett., vol. 99, no. 14, p. 144801, 2007. doi:10.1103/PhysRevLett...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
3
9e990c50-9806-46aa-9e65-e98bf8fcc9d8
doi:10.18429/JACoW-IPAC2016-TUPMW006 [12]A. Frascaet al., “Optimizing Pb beam losses at the LHCb for maximum luminosity”,J. Phys. Conf. Ser., vol. 2687, p. 022002, 2024. doi:10.1088/1742-6596/2687/2/022002[13]G. Iadarolaet al., “Xsuite: An Integrated Beam Physics Sim- ulationFramework”,inProc. HB’23,Geneva,Switzerland,...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
3
d33f91e4-ebf3-49d9-bf0e-69d960bee53b
riences with the Advanced Interface for FLUKA and other Monte Carlo codes”,EPJ Web Conf., vol. 302, p. 11005, 2024. doi:10.1051/epjconf/202430211005 [19]A. Mereghettiet al., “The FLUKA LineBuilder and Element Database”,inProc. IPAC’12,NewOrleans,LA,USA,May 2012, pp. 2687–2689 [20]E. B. Holzeret al., “Beam loss monitori...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
3
86e7c2c2-7f12-4a2f-a29b-d6b1510f37ce
p. 071003, 2019. doi:10.1103/PhysRevAccelBeams.22.071003 [23]J.Jowettet al., “Bound-FreePairProductioninLHCPb-Pb Operationat6.37ZTeVperBeam”,inProc. IPAC’16,Busan, Korea, May 2016. doi:10.18429/JACoW-IPAC2016-TUPMW02817th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-9545...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1020.pdf
3
40bfe5ce-be2f-4ec9-89e4-e523069fb690
STUDY OF THE TOUSCHEK EFFECT IN THE FCC-ee G. Broggi∗1,2,3, M. Boscolo3, R. Bruce2, G. Iadarola2, L. Pauwels2, S. Redaelli2 1Sapienza University of Rome, Rome, Italy 2CERN, Meyrin, Switzerland 3INFN-LNF, Frascati, Italy Abstract The Future Circular electron-positron Collider (FCC- ee) is a design study for a 90.7 km ci...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1021.pdf
0
b2aeebfa-5d8d-406e-beec-757a093b3a9e
lifetime-limiting processes. This paper presents a study of the Touschek effect in the FCC-ee, performed using a MonteCarloTouschek-scattering simulationroutine newly implementedintheXsuiteframework. Theresultsinclude Touschek-lifetimeestimatesfortheFCC-eeandanevalua- tionofthearisingbeamlosspatterns. Theperformanceof ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1021.pdf
0
0f587ec0-79ba-433f-94f8-fface1d3f6d7
canconverttransversemomentumintolongitudinalmomen- tum. Iftheresultingmomentumdeviationexceedsthemo- mentumacceptanceofthemachine,oriftheresultingclosed- orbitorbetatronoscillationsexceedthephysicalordynamic aperture, particles are lost from the beam. The Touschek effect is typicallythe primary beam lifetimelimiting ef...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1021.pdf
0
e7b647d1-7405-46f5-9c52-5d3327c499b4
This paper introduces the Touschek scattering simulation routine recently implemented in the Xsuite framework (full details can be found in Ref. [ 4]), and presents the results of its application to the FCC-ee 𝑍operation mode. This representsthemostcriticalcasefortheTouschekeffect,as ∗giacomo.broggi@cern.chit correspo...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1021.pdf
0
2acb18da-95ec-4625-8869-09ee3d58c53e
ing rate for particles with momentum deviation |𝛿| > 𝛿𝑚is evaluated via Monte Carlo integration as [ 6]: 𝑅MC=𝑉 𝑁𝑀 ∑ 𝑖=1[𝑣∗ 𝛾2𝑑𝜎∗ 𝑑Ω∗sinΘ∗𝜌( ⃗ 𝑥1)𝜌( ⃗ 𝑥2)] 𝑖=𝑀 ∑ 𝑖=1𝑟𝑖,(1) where𝑉is the sampled phase-space volume, 𝑁the total numberofsimulated scattering events,and 𝑀thenumber of scattered particle...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1021.pdf
0
e18e0738-c7f7-4cb0-acff-63f960191b13
scattering particles are sampled from a six-dimensional Gaussian phase-space distribution at the given lattice lo- cation,usingthelocalopticalfunctions. Thepolarandaz- imuthalscatteringangles Θ∗andΨ∗inthecenter-of-mass frame are also sampled, and the post-scattering momenta are obtained via a relativistic Lorentz boost...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1021.pdf
0
8d7931ec-20ec-44db-af87-a3dc34d27a3c
the current and the preceding TouschekScattering ele- ment. The Touscheklifetimeis then 𝜏𝑇=𝑁𝑏 ∑lost𝑅𝑖, (3)17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP1021 104 MC1.A02: Lepton Circular CollidersMOP102...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1021.pdf
0
e5b8fb8e-a190-45f8-ac66-d615943a3932
Figure 1: Local momentum acceptance profile forthe FCC-ee (LCC V106.2) 𝑍operation mode. where𝑁𝑏is the bunch population and the sum runs over all lost macroparticles. A speed-up strategy is applied by retainingonlythehighest-weightparticlesthataccountfor afixedfraction(e.g.,99%)ofthetotalsimulatedrateasin Ref. [6]. T...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1021.pdf
1
aa2b4376-bbf9-4832-859f-d1e97de5dc11
tions against experimental data, yielding very good agree- ment [4,19]. Local Momentum Acceptance A prerequisite for the Touschek simulation is an accurate profile of the local momentum acceptance (LMA) 𝛿𝑎(𝑠) along the ring. This is obtained by tracking on-closed-orbit test particles with varying momentum deviations...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1021.pdf
1
ca64a7c4-38ab-4b2a-be4f-a4d2c96e0b4b
positronbeam(Beam1)atabeamenergyof45.6GeV,corre- spondingtothe 𝑍operationmodewiththeLocalChromatic Correction(LCC)opticsV106.2[ 20],usingthethenominal colliding-beam parameters in Table 1. Atotalof1214Touschekscatteringcenterswereplaced non-uniformlyalongthe90.7kmring,withdensersampling inregionswheretheopticsvarymore...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1021.pdf
1
fa2a264c-71a4-413e-9e58-b5e135296de9
collision scheme, a detailed aperture model, and the full collimation system. Beam–collimator interactions were modeled using BDSIM/Geant4 via the Xsuite–BDSIM cou- pling [17,21] provided within Xcoll. Synchrotron radiation effects—including damping, energy recovery in the RF cav- ities,andmagneticlatticetapering—werei...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1021.pdf
1
991dc2bf-fc07-420f-8233-baf434814647
shadow of other beam loss mechanisms, in particular ra- diative Bhabha scattering (RBS) at the interaction points, which dominates the beam lifetime with 𝜏RBS≈ 20min- utes[22]. ThisconfirmsthatTouschekscatteringdoesnot posealimitationonthebeamlifetimeintheFCC-ee. Given that the Touschek loss rate is suppressed with in...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP1021.pdf
1