00b87e25-13eb-40c8-a530-912be23c3c59 | copper. The latter was obtained via fitting the displacement
curves of the initial simulations and experimental measure-
ments conducted. These coefficients were subsequently in-corporated into refine d numerical simulations to obtain a
more accurate representation of the stress –strain state
within the sealing regi... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 0 |
df544ffe-2efb-43d3-b93d-c7e2758b6830 | During this transition, the metal foil absorbs a certain portion of the beam, thereby altering its characteristics.
The AREAL linear electron accelerator at the CANDLE
Synchrotron Research Institute [1- 6] is equipped with two
output windows, each consisting of two flanges, a 50 μm thick Grade 2 titanium foil, and ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 0 |
28dff4ca-955c-49b1-a8cc-037799b1973a | able joints, vacuum brazing or welding is applied. These can also be classified into two types: brazing using molten filler material and diffusion bonding using specially de-
signed foil -type filler materials. A summary of these ap-
proaches is illustrated in Fig. 2.
Figure 2: Methods of output window fabrication... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 0 |
c108e0eb-9e02-40a5-a4cb-777cac7d789d | investigate not only Grade 2 but also Grade 5 titanium foils.
The stability of the foil in the assembly depends on its
diameter. In the AREAL linear electron accelerator, one side of the output window uses a DN35CF –DN40CF
flange [12], while the other side uses an ATLAS flange [13]. In both cases, the foil is fixe... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 0 |
d20f3b96-56c8-42a2-9b78-b2a3ce6cf235 | accelerator output windows is primarily subjected to atmospheric pressure. As a result, it experiences
deformation during each vacuum pumping cycle. Under
identical thickness conditions, Grade 2 and Grade 5 titanium foils exhibit different mechanical behaviors [14-
15]. Table 1 a comparison of these materials shows... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 0 |
9a7e3c86-8c96-49d9-a926-28a351b72a4b | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP7088
742 MC7.T14: Vacuum TechnologyMOP7088 Monday: Poster session
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, pub... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 0 |
53dd68e3-56c8-4ee3-a4cd-9861cbea62c7 | Thus , it is essential to conduct a detailed comparative
analysis of Grade 2 and Grade 5 titanium foils to determine
their suitability and preferred application in accelerator
technology.
INITIAL DATA OF SIMULATION
The process was simulated using the SIMULIA
ABAQUS 2019 environment. The initial geometric
param... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 1 |
c7468f1d-1956-4806-b178-9b1d4ddd50c8 | 1 atm was applied. The pressure on the UHV side was
assumed to be 0 atm, as vacuum levels of 10⁻⁸ –10⁻¹⁰ Torr,
commonly achieved in accelerator systems, do not induce significant mechanical effects.
The plastic behavior of the flange and foil materials was
defined using the stress –strain curve s, adopted from [ ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 1 |
5af25f15-b05e-4469-a328-9651c7f8147e | deviation was 0.2 μm. Meanwhile, the preliminary
simulation was conducted with the friction coefficients
from the literature [7]: stainless steel (SS) 304L with
titanium – 0.48, SS304L with oxygen- free high
conductivity (OFHC) copper – 0.15, and titanium with
OFHC copper – 0.62. The deflections of the referenc... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 1 |
6f76babb-c8ab-4a8c-a420-d30925e54baa | phase – tightening phase, and second phase – vacuum
pumping phase. This allowed us to investigate the stress
state of the output windows more efficiently.
According to simulations conducted the stress intensity
distribution s (Von Mises stresses ), and displacement
(deflection) in the direction of the y -axi... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 1 |
6ecadc58-1974-4b65-89fd-00ee37d905d1 | To evaluate the stress -strain state in the sealing region,
two contact interfaces were analyzed: the knife edge– foil
interface (upper flange in Fig . 4) and the knife edge –gasket
interface (lower flange in Fig . 4). At the initial stage, both
interfaces demonstrate similar stress distributions and
comparable ma... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 1 |
72945872-e865-486a-87ec-773d32d78945 | respective thicknesses, indicating stress relaxation during
vacuum pumping. Conversely, in the knife edge –foil
interface (upper flange, Fig s. 4a, b ), the corresponding
peak stresses are approximately 607.3 MPa and
544.2 MPa. For t he 40 μm foil, the highest stress is
observed at the knife edge –foil interface... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 1 |
c182d16a-0b71-43d5-9ba7-beb7b6803af0 | Figure 5 illustrates the Von Mises stress distribution
zones of the output window with titanium Gr -5 foil after
the second phase .
For the titanium Gr -5 output windows, during the initial
stage, both interfaces also exhibit comparable stress
distributions and magnitudes. The peak stresses –
approximately 630.... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 2 |
d74fdcb1-cf60-4dba-9baa-aa4b32bcf315 | (c).
In the subsequent stage, however, both the stress
distribution and magnitude differ between the two
interfaces. In the knife edge– gasket contact zone (bottom
flange, Fig. 5a, b, c ), the maximum stress at the knife -edge
tip decreases to approximately 535.98, 614.2, and
591.9 MPa for the respective thickn... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 2 |
2ac6ac4c-6788-415d-8339-5e6c0d5a29c5 | interaction zone. For other two thicknesses, the higher stress concentration is at the tip in the knife edge –foil
interface. The explanation of that phenomenon at this stage
is quite hard and requires further research. The Von Mises stress distribution curves in the cent er
nodes of the foils are demonstrated in t... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 2 |
b4a74962-8b12-452d-9a8e-125b0738838a | stress state in the foil exceeded 300 –320 MPa. Thus, the
titanium Gr -5 foil with δ = 30 μm thickness still has a
minimum 50 MPa stress gap, and it is more or less stable.
The deflection curves of the foils for the same center
region are illustrated in Fig. 7. From Fig. 7, it is noteworthy
that the curves for t... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 2 |
eefab00f-83f8-4e26-97c7-d6dcfcb3923e | CONCLUSION
Investigation of the accelerator output windows with ti-
tanium Gr -2 and Gr -5 foils was carried out using the exper-
imental correction of the friction coefficients for the more
precise stress state simulations. According to the research
conducted, from the mechanical perspective (without the
thermal ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 2 |
c3b51aff-ba59-497f-ad2b-eed9bce03358 | REFERENCES
[1] G. Zanyan et al ., “Low emittance booster design for CAN-
DLE storage ring” , in Proc . I PAC ’11, San Sebastian, Spain,
Sep. 2011, paper THPC137, pp. 3209 -3211.
[2] V . M. Tsakanov et al., “AREAL test facility for advanced ac-
celerator and radiation source concepts”, Nucl . Instrum .
Methods ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 3 |
e9e6e833-5cb1-48e1-a83d-f5a1e9ce64a1 | [5] B. Grigoryan et al. , “Status of AREAL RF Photogun Test Fa-
cility ”, in Proc . I PA C ’14, Dresden, Germany , Jun. 2014,
pp. 620-623.
doi:10.18429/JACoW- IPAC2014- MOPRI017
[6] A. Gevorgyan et al. , “Design and performance of ultimate
vacuum system for the AREAL test facility ”, in Proc .
I PA C ’14, Dresde... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 3 |
6ecd458d-59ff-470f-a501-1d8d6ba3018d | doi:10.53297/18293387- 2024.1-9
[9] H. Isunts et al. , “Overview of accelerator output windows,
their parts and preferred materials ”, J. Instrum. , vol. 20,
no. 9, p. T09002 , Sep. 2025.
doi: 10.1088/1748- 0221/20/09/T09002
[10] H. Isunts et al. , “Deformed state’s simulation of the first -
grade titanium foil... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 3 |
8648718e-814f-4219-9b44-aa9827ab6fd4 | [13] https://www.atlasuhv.com/part/fwfss- 0275
[14] https://asm.matweb.com/search/Specific-
Material.asp?bassnum=mtu021
[15] https://asm.matweb.com/search/specific-material.asp?bassnum=mtp641
[16] C. N. Elias et al., “Mechanical properties, surface
morphology and stability of a modified commercially pure
high ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7088.pdf | 3 |
b3e675c1-01d4-436f-9251-9b030e9dd5b9 | SEY REDUCTION USING ULTRATHIN T iN/NbN MULTILAYERS FOR
ACCELERATOR APPLICATIONS
G. Sattonnay‡, Y. Pisi†, D. Longuevergne, Université Paris- Saclay, CNRS/IN2P3, IJCLab, Orsay,
France
E. Blanquet , A. Mantoux, Science et Ingénierie des Matériaux et Procédés, Saint -Martin -d'Hères,
France
Abstract
Multipacting a... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7089.pdf | 0 |
c13e4634-f395-4b5c-9420-7dd9ab1d685d | systems. Reducing the secondary electron yield (SEY) of vacuu m-facing surfaces is therefore a key strategy to miti-
gate these effects. To mitigate these effects, several strate-gies have been proposed, in particular the deposition of
thin films designed to reduce the secondary electron yield
(SEY) of the relevant s... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7089.pdf | 0 |
e02b9b8c-448b-4ac3-8a48-e37afef75702 | ration achieves a significantly redu ced SEY , reaching 0.98
after conditioning.
INTRODUCTION
Particle accelerators such as the Large Hadron Collider
(LHC) are limited by secondary electron emission, which can trigger electron cloud formation through multipacting
(secondary electron yield ( SEY ) > 1), leading ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7089.pdf | 0 |
1b2346a8-65f4-43df-aa15-33f4fcd1b5a2 | create potential barriers (~0.2 eV) that reduce electron
transmission and promote confinement, especially for low -
energy secondary electrons. Increasing the number of interfaces enhances energy dissipation and lowers effective
S E Y. TiN and NbN are particularly suitable due to their low
SEY , structural compati... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7089.pdf | 0 |
f010a7d6-7698-4964-989d-f6b970e50a0d | sputtering from TiN and Nb targets, with optimized condi-
tions (0.3 Pa, 40 sccm Ar, 200 mA) to ensure slow, uni-
form growth. Individual layer thicknesses (~2 –3 nm) were
controlled via depos ition time (1 min 30 s per layer), and
various architectures were explored by adjusting the num-
ber of layers and the top... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7089.pdf | 0 |
937276ed-0175-429e-a2da-5ff8a41949b1 | 500 eV argon ion beam with an abrasion spot size of 400
µm. A total of 200 sputtering steps were carried out, each
lasting 5 s. After each step, a survey spectrum was rec-
orded, along with high -resolution spectra for the elements
of interest (C, N, Nb, and Ti). The XPS depth profile
(Fig. 1) shows the elemental ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7089.pdf | 0 |
769e472c-3ebc-4208-8d0d-b6dab3b5d817 | Ti-rich layers. This may result from partial interdiffusion
during deposition. It may also reflect an intrinsic limita tion
of XPS: its information depth (~5 –10 nm) exceeds the in-
dividual layer thickness (~3 nm), leading to signal contri-
butions from adjacent layers. ________________________________ ___________... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7089.pdf | 0 |
1649a5eb-8daa-4469-a1a6-2c300bb2b156 | Figure 1: Depth distribution of C, O, N, Ti, Nb, and Si ele-
ments in a five -stack NbN/TiN/NbN/TiN/NbN/Si multi-
layer structure.
Figure 2: XPS spectra of a NbN/TiN/NbN/TiN/NbN/Si
multilayer deposited by PVD: Ti 2p₃⁄₂ peak (top) and Nb
3d₅⁄₂ peak (bottom) .
Finally, the multilayer architecture was confirme... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7089.pdf | 1 |
dabb5d0d-c4ab-465c-a930-7743fa5cf86a | Figure 3: STEM study of the five -layer
NbN/TiN/NbN/TiN/NbN/Si multilayer deposited by PVD: (top left) STEM image, (top right) STEM -EDX map of Ti,
(bottom left) STEM -EDX map of Nb, and (bottom right)
STEM -EDX map of Nb and O.
Secondary Electron Yield Measurements
Secondary electron yield (SEY) measurements w... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7089.pdf | 1 |
6538d9ac-8bc0-4363-893e-098d56d1174f | [1], except for the five -layer stack, where δₘₐₓ decreases to
1.08. For multilayers with NbN as the topmost layer, the
SEY of the NbN/TiN/NbN/Si trilayer approaches that of
single NbN films. Notably, a δₘₐₓ value of 0.99 is obtained
for the five -layer NbN/TiN/NbN/TiN/NbN/Si multilayer .
These results are partic... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7089.pdf | 1 |
98161399-b9e8-469e-b4a5-37ad2bc2b543 | 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP7089
MC7.T14: Vacuum Technology 747Monday: Poster session MOP7089
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distr... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7089.pdf | 1 |
290b88cf-40af-47bd-a22c-40455ad5ad01 | Figure 4: Fully conditioned SEY curves of: (top) multi-
layers with TiN as the surface layer, and (bottom) multi-
layers with NbN as the surface layer. CONCLUSION
TiN/NbN thin -film multilayers show significant poten-
tial for reducing the secondary electron yield (SEY) of sur-
faces. The most promising results are o... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7089.pdf | 2 |
03d505cc-3151-4911-811b-f091725f2b8e | “The continuing story of secondary electron yield measure-
ments from TiN coating and TiZrV getter film”, SLAC,
Menlo Park, CA, USA, Rep. SLAC -TN-04-046/LCC-0146,
Aug. 2004.
[2] R. Valizadeh, O. B. Malyshev, S. Wang, S. A. Zolotovskaya, W. Allan Gillespie, and A. Abdolvand, “Low secondary elec-
tron yield engineer... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7089.pdf | 2 |
c594fa5b-99d6-4347-8484-3742aad72dbe | BEAM MEASUREMENTS WITH CRYOINSERTS IN SIS18
L.H.J. Bozyk∗1, P.J. Spiller1
1GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
Abstract
Inoder to increase themaximum achievableintensity of
mediumchargestateheavyionbeamsinSIS18atGSIfor
FAIR-operation, the installation of cryoinserts is foreseen.
These cryo... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 0 |
38443247-2a6a-4df4-8ddd-aae8bb7c31f8 | areductionofthestaticpressureextendingseveralmeters
after cooldown was observed.
In 2025 the first beam experiments with medium charged
Uranium beams and the cryoinserts took place to observe
their influence. The charge exchange could be measured,
showing a significant decrease due to the cryoinserts and
alsoaslightinf... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 0 |
8f4da236-784b-44dc-b31a-c168a2ef7799 | chargelimittohighernumberofparticles. Unfortunatelythe
probability of charge exchange in collisions with residual
gas particles for such ions is much higher, than for higher
charge states like U73+. As charge exchanged ions have a
differentmagneticrigiditythanthereferenceion,theyget
separatedfromthecirculatingbeam. Whe... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 0 |
85b32751-3da1-425f-90a7-2d3198693695 | There are several technical measures to shift this limit,
like lowering the static gas density or the installation of low
desorbing surfaces, which is applied in the ion catchers, see
[1]. The intensity of SIS18 could be increased significantly
[1,2],buttheFAIR-intensitiesarenotyetreached. However,
simulationsusingcryo... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 0 |
853035b4-70db-41ba-a20b-338a660c03a3 | much higher than on NEG surfaces.
A prototype with cryogenic inserts has been set up and
tested. Itisdescribedin[ 4,5]. Itcontainsgold-coatedcopper
surfaces,whicharecooledbyacommerciallyavailablecold
head. Thiscoldheadcanberemovedwithoutbreakingthe
beam vacuum for the vacuum-bakeout. It has been installed
in SIS18 and ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 0 |
a3b69c49-35d8-4bae-a5fb-b25e4812680f | tothesecycles,highintensitybeamswith 2−3⋅1010injected
particles were stored to measure collimator currents. Be-
foreandaftercooldownrespectively,theintensitydependent
transmission for different ramping rates was measured.
Figure1showspressureevolutionduringacooldownin
Section01, wherethe cryoinsertsarelocated. The cryo... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 0 |
3faf489e-af45-426f-b47a-f6d32bfbc6fa | beam life time. Nevertheless, moving the gate valve next to
thecryoinsertsinducesapressurebump,whosedecreasecan
beinvestigatedbylifetimemeasurements. Figure 2shows
lifetime evolution at three different temperatures. The lower17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: 97... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 0 |
b9327b7d-e3e9-4563-aed6-14fc9110bc33 | 0 5 10 15 20 25 30 35 40
Time in Minutes024681012Lifetime in s
16 K
80 K
200 KFigure 2: Lifetime evolution at three different temperatures
before and after valve movement next to the cryoinserts.
0123456
Time in s00.20.40.60.811.2Normalized Intensity Evolution
50100150200250
Figure 3: Evolution of normalized intensity ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 1 |
b7aded90-fe95-4b4a-bb7b-ae700ed86f89 | The blackline represents a typical cycleof a previous mea-
surementwithcomparableintensitybeforetheinstallation
ofthecryoinserts. Nevertheless,thestoredintensityisabove
thecapabilitiesofthevacuumsystem,resultinginthefast
intensity drop within the first second.
Collimator Currents
The most explicit result is the measure... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 1 |
4b49c9cf-b9f9-426e-b4e9-06d59f6bcaab | S07 S08 S09 S11 S12Figure5: Evolutionofcollimatorcurrentdynamicasafunc-
tion of the cryoinserts’ temperature.
0 50 100 150 200 250
Tem pearture in K102030405060708090100Collimator Current Inside / OutsideS01 S02 S03 S04 S05
S07 S08 S09 S11 S12
Figure 6: Evolution of current ratio between inside and
outside as a functio... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 1 |
c5a04e11-0509-463e-9ded-2cbdc4020d51 | remain constant, in S02 the dynamics constantly decrease
withdecreasingtemperatureinS01. Itisremarkable,thatno
stepoccurswithfallingtemperature,asintheresidualgas
densityshowninFig. 1. Thisstepiscausedbytheemerging
of Hydrogen-pumping. But as the charge exchange cross
sections for Hydrogen are by more than a factor 10 ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 1 |
49c97c42-2e4f-48a2-bbe7-004b77422baf | the cryoinserts changes the gas composition from high to
low ratio.
Variation of Intensity and Ramping Rate
Beforeandaftereachcooldown,i.e. atwarmandcoldcry-
oinserts,theintensitydependenttransmissionfordifferent
rampingratesofnormalproductioncyclesweremeasured.
Due to increasing chargeexchange rates and self amplifica... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 1 |
f4093b4c-77c2-4757-a99c-21ad626dd1a1 | 0 5 10 15 20 25 30910×
Injected Intensit y051015202530910×Extracted Intensity9 T/s, warm
9 T/s, cold
1 T/s, warm
1 T/s, coldFigure7: Extractedbeamintensityasfunctionofinjected
beamintensityfordifferentrampingratesaswellasforwarm
and cold cryoinserts.
123456789 1 0
Ram pingrate in T/s181920212223242526910×Number of Extr... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 2 |
5167856f-5009-4826-8e23-a01ce8643b21 | higher extraction intensities at high injected intensities. As
the available intensity during 2025’s machine development
beam time was limited to 3 ⋅ 1010injected particles, for
high ramping rates no saturation is visible yet. Neverthe-
less,thedatawithcoldcryoinsertsexceeddatawithwarm
cryoinserts.
In Fig.8the dependen... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 2 |
8cfcd6c5-9778-407b-9218-c10b0a596d14 | warm and cold cryoinserts are compared. Injection loss,
Rf-capture-lossandlossesduringinjectionplateauareun-
affectedbythecryoinsert’stemperature. Butasexpcected,
the losses during acceleration ramp decrease with cooled
cryoinserts.
SIMULATION
As the StrahlSim code [ 9] was used to predict improve-
ments by cryogenic s... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 2 |
09b3a879-3bf4-4207-9051-57ed8078b6e2 | oinserts decrease the amount of beam loss.
which serves as a basis for the simulations. Aging effects of
NEG-surfacesaswellasincreasedoutgassingareasdueto
different installations or leaks have to be considered to re-
produce a measured pressure profile consisting of 29 points
along the ring. Pressure gauges show a Nitr... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 2 |
64db395f-daa4-4e70-ba39-6596e97d608b | measurementsinastaticvacuumcanbereproduced. Increas-
ing the intensity and going to dynamic vacuum requires all
available parameter within the simulation, which also in-
cludes the “history” of a vacuum system, i.e. the number of
cycles in continuous operation. Results of such simulations
areshowninFig. 8. Theagreement... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 2 |
d507273c-d89f-491b-a503-5fbc9fc9a992 | In the next steps, the cryoinserts design gets optimized
for a series production. The copper sheets not necessarily
havetoberound,whichisdifficulttomanufacture. There-
fore, they will have ten edges in future. Also the areas of
thermal contact betweencomponents were revisedin order
toachieverhighersurfacepressureandsuc... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 2 |
c8dcab0b-b744-4f94-8f9e-ca8f799c05b2 | REFERENCES
[1]P.J.Spiller,L.H.J.Bozyk,andP.Puppel,“SIS18–Intensity
Recordwith Intermediate Charge State HeavyIons”, in Proc.
IPAC’11,SanSebastian,Spain,Sep.2011,paperWEPS003,
pp. 2484–2486.
[2]L.BozykandP.Spiller,“SIS18OperationwithU28+”,inProc.
IPAC’24, Nashville, TN, USA, May 2024, pp. 1661–1664.
doi:1/zero.alt4.1842... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 3 |
31192fcf-c82b-4660-b882-b4b5bebf8de3 | [5]L. Bozyk, S. Aumüller, and P. Spiller, “Cryogenic surfaces
inaroomtemperatureSIS18ioncatcher”,in Proc.IPAC’23 ,
Venice, Italy, May 2023, pp. 4283–4286.
doi:1/zero.alt4.18429/JACoW-IPAC2/zero.alt423-THPA139[6]L.BozykandP.Spiller,“Cryogenicinsertsintheroomtem-
perature synchrotron SIS18 at GSI”, in Proc. IPAC’25 , Tai... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 3 |
31546b9b-6fdf-4716-bf8a-e676fa959fd5 | Sect. B, vol.372, pp.102-108, 2016.
doi:1/zero.alt4.1/zero.alt416/j.nimb.2/zero.alt416./zero.alt41./zero.alt447
[9]P.Puppel, “Orts- und zeitaufgelöste Simulation strahlin-
duzierter dynamischer Vakuumeffekte in Schwerionen-
synchrotrons”, Ph.D. thesis, Physics Department, Goethe
UniversitätFrankfurt, Frankfurt, Germany... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7091.pdf | 3 |
fe4636a4-1589-4f77-9761-353613eb509d | PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF
TUNNEL∗
G. Ciovati†, D. Hamlette, D. Heck, J. Jordan, A. Wildeson,
Thomas Jefferson National Accelerator Facility, Newport News, United States
B. Busetto, L. Caruso, E. Maccallini, P. Manini, D. Nicolosi, F. Siviero,
SAES Getters S.p.A., Lainate, Italy
S. Wulfsberg... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 0 |
f665c69f-f4c7-46f3-ba5a-2fa56266fb66 | highradiationduringbeamoperation. Theparticulatecount
fromtwoNEGpumpsbasedon ZAO®getteralloywasmea-
sured with a particle counter in a clean-room. The pumps
were assembled onto a hermetically sealed setup which was
placed in the CEBAF tunnel. The setup was exposed to
24 h beam operation for ∼ 230days. The total gamma-r... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 0 |
bcfa4c4d-b11c-4dde-bfd6-6e864dec1b9a | beconsistentwiththatofanon-irradiatedone,corroborat-
ing the absence of significant damage to the ZAO®NEG
material due to irradiation.
INTRODUCTION
Non-evaporablegetter(NEG)pumpsarebeinginstalled
in the pump drops of both the warm girders and the cry-
omodulesthatareinstalledintheContinuousElectronBeam
AcceleratorFacil... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 0 |
f0b924c9-340b-4358-9f6f-5d2ddc48a6a0 | surface [2–4]. The NEG pumps from SAES Getters have
low particulate emission and they have been qualified for
use in the vacuum system of SRF cavities [ 5–7]. They have
∗This material is based upon work supported by the U.S. Department
of Energy, Office of Science, Office of Nuclear Physics under contract
DE-AC05-06OR2... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 0 |
3e1196bd-03ee-4167-b374-042a0b25733e | this study. Both pumps are made of the ZAO®alloy. The
CapaciTorrHV200isthesamemodelastheoneusedinthe
pump-dropsofrefurbishedcryomodulesandwarmgirders.
The HV 200 and Z 400 pumps have a nominal hydrogen
pumping speed of 200 l/s and 400 l/s, respectively.
The NEG cartridges were cleaned in isopropyl alcohol
with ultrason... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 0 |
380f6d8d-d229-4c0e-aaeb-4f8ced5f641a | sealednylonbag,thenassembledwiththeNEGpumpsas
shown in Fig 2.
Figure1: NEGpumpsCapaciTorrHV200(a)andZ400(b)
in the clean room.
Each NEG pump was cleaned with ionized nitrogen on
abovea particle counter (Lighthouse Solair 3100) inside the17th International Particle Accelerator Conference, Deauville, France JACoW Publish... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 0 |
adfb97c2-7b7c-4085-b0f9-1ec8738700c3 | Figure 2: Schematic of the vacuum setup with the two NEG
pumps.
cleanroomuntilzeroparticleswerecounted. Theparticle
counter samples a volume of 4814 cm3every 10 s. After
particulate blow-down, the pump was inserted in a vacuum
manifold,evacuated,helium leakcheckedand activatedby
heating it for 1 h at ∼ 550 °C with a NE... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 1 |
94699f61-bb9c-4af9-946a-85bb31dfbbdc | isactivatedonelasttime,afterevacuationandheliumleak
check with a cart equipped with a turbo-molecular pump,
a full-range cold-cathode gauge (CCG) and a residual gas
analyzer (RGA). Afterwards, the right-angle valve (RAV) at
the end of the 4-way cross was closed. The pressure mea-
suredbytheCCGontheturbo-pumpcartbeforec... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 1 |
37e930bd-3e09-4f78-a352-b5e9b523c66e | anopportunitytodeliverahighradiationdoseinashorter
time. Four pairs of opti-chromic dosimeter rods were taped
to the nylon bag enclosing the pumps. Figure 3shows a
picture of the placement of the vacuum setup in the CEBAF
tunnel. Beam operation in CEBAF for experimental nuclear
physics occurred between September 11, 20... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 1 |
3fd85013-e1a9-422f-857b-bde2be8196d7 | NDXdetector,integratedovertheperiodsofbeamoperation,
was150kradof 𝛾-raysradiationdoseand11kradofneutron
radiation dose.
The vacuum setup with the pumps was transferred to the
chemical room in the Test Lab. The nylon bag broke into
pieces as a result of the radiation exposure. The vacuum
setupwaswipedcleanwithisopropan... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 1 |
582ea8f3-c2a8-403b-a538-d206b6017fe3 | nitrogen before installation on the 4-way cross before and
after removing them from the 4-way cross, after one final
activation.
Figure 4 shows plots summarizing the total particulate
countsaftereachoperation,listedinthex-axis. TheHV200
pump had significantlyhigher particulate counts compared
to the Z 400 pump after th... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 1 |
1d86ec1d-6332-48c1-b9c7-ad9119664f1f | theblowingwithnitrogenafterthethirdactivationandthe
blowing after irradiation. Both pumps remained cleaned
afterlong-termstorageintheclean-roomandtheparticulate
countwasthelowestafterthefinalactivation. Therefore,the
data suggests no permanent damage was done to the pumps17th International Particle Accelerator Conferen... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 1 |
afa6f602-649d-4647-a5db-3efdf43813b1 | asaresultof 𝛾-raysandneutronradiationdose,whichmight
have resulted in an excess of loose particulate.
Figure 4: Total particulate count from the NEG pumps mea-
suredintheISO4cleanroomaftereachpreparationstep: (a)
particulatesizerangingbetween 3µm-10µm,(b)particulate
sizerangingbetween 0.3µm-1µm. Emptysymbolsarefor
the... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 2 |
15f54fdc-33d1-42e0-b160-8dbba260fffd | at room temperature.
Thepumpingspeedcurvecomparisonbetweenabrand-
newpumpandtheirradiatedpumpisreportedinFig. 5. The
longexposureatahighdoselevelhasamarginaleffecton
thepumpingspeedfeaturedbythe CapaciTorr®HV200
pumpforboth H2andCO.Moreinterestingly,the sorption
capacity slope for CO barely changes, indicating that the... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 2 |
659ec8e9-bf84-48ca-ac72-eb0718287cc2 | frombeamoperationintheCEBAFtunneldidnotresultina
significantincreaseoflooseparticulate,whichcouldimpact
the cleanliness of the beamline, nor in a significant reduc-
tion of the pumping speed. Such results do confirm that the
ZAO®material is well suited for usability in radiation hard
environmentsforprolongedtime, allow... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 2 |
129b33c4-02b5-485d-8c9c-ad4df872c0fc | doi:1/zero.alt4.11/zero.alt43/PhysRevAccelBeams.27./zero.alt4848/zero.alt42
[2]J. Benesch, “Field Emission in CEBAF’s Superconducting
RF Cavities and Implications for Future Accelerators”, 2007,
doi:1/zero.alt4.4855/zero.alt4/arXiv.physics//zero.alt46/zero.alt46141 ,
[3]G. Geng, “Hydrogen Condensed on to Cold Cavity Su... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 2 |
e1cfc74f-cdac-4aba-88bc-676a516a6fc7 | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP7095
MC7.T14: Vacuum Technology 755Monday: Poster session MOP7095
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, pub... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 2 |
11d8f075-b94d-4a58-ac2d-ba280e7ef7ef | [5]G.Ciovati,R.Geng,Y.Lushtak,P.Manini,E.Maccallini,and
M.Stutzman,“Operationofahigh-gradientsuperconducting
radio-frequencycavitywithanon-evaporablegetterpump”,
Nucl. Instrum. Methods Phys. Res. A , vol. 842, pp. 92–95,
2017. doi:1/zero.alt4.1/zero.alt416/j.nima.2/zero.alt416.1/zero.alt4./zero.alt448
[6]S. Lederer, L.... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 3 |
f1c073b0-4ea0-4c48-95aa-6323d24ef7ac | 2023. doi:1/zero.alt4.18429/JACoW-IPAC2/zero.alt423-THPA15/zero.alt4
[8]T.T.Arkan etal.,“LCLS-II CryomodulesProduction Expe-
rience and Lessons Learned TowardsLCLS-II-HE Project”,
inProc.SRF’21 ,EastLansing, MI, USA,p. 832, Oct.2022.
doi:1/zero.alt4.18429/JACoW-SRF2/zero.alt421-THPTEV/zero.alt4/zero.alt43
[9]SAESGetter... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7095.pdf | 3 |
e610e94c-9753-450e-9161-69887141ab06 | ALBAII VACUUM SYSTEM: DESIGN EVOLUTION AND PROTOTYPING *
R. Parise†,1, B. Francisco1, L. Carvajal1, J. Álvarez1, O. Traver1, G. Peña1, L. Ribo1, P. Salmerón1,
M. Llonch1, M. Quispe1, N. Gonzalez1, J. Casas1, F. Perez1, K. Blümer2, R. Schwertfeger2,
H. Henninger2, C. Colldelram1
1ALBA Synchrotron, Cerdanyola del Va... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 0 |
cd6e63d9-d583-4090-ba68-a5bd76d9c61f | ometry providing a 22 mm horizontal aperture, 1. 25 mm
wall thickness and clearances of 1 mm to the magnet poles.
Its structural response shows 13 MPa maximum stress with
deformations of 3 µm. A short bellows is foreseen between
each pair of BPM blocks to absorb chamber displacements from alignment tolerances and ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 0 |
a9dba4a3-6446-48b0-828a-9690869190df | generation diffraction- limited synchrotron light source [1].
The compact lattice imposes strong constraints on the vac-uum system, including magnet aperture, synchrotron radi-
ation power, conductance, impedance, and injection- effi-
ciency requirements. To satisfy these constraints, the
chamber design has evolved... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 0 |
d87456d0-d9cf-4116-8edc-e182a0eaedd6 | Each arc forms one vacuum section delimited by two gate
valves , with NEG -coated chambers activated ex -situ be-
fore installation .
A typical arc includes five copper -alloy dipole chambers ,
five pumping locations, and five crotch absorbers, while part of the synchrotron radiation is distributed directly onto th... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 0 |
853ba7a0-0389-41cd-984c-43c7c71c1730 | blocks, and crotch absorbers at selected locations. Com-
pact MO -type flanges are used where space is critical,
while adapted CF ones are kept where required .
DESIGN EVOLUTION
The initial vacuum chamber concept was based on a 16
mm circular internal cross -section. Further lattice and in-
jection studies showed... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 0 |
f0e864c9-744b-4017-b6fe-7d37e5405775 | clearance of 1 mm to the chamber wall had to be main-
tained, the available external envelope imposed a strong
geometrical constraint. Figure 1 shows the resulting avail-
able area obtained from the superpo sition of the surround-
ing magnet pole profiles. The boundary corresponds to a 1 mm offset from the nearest mag... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 0 |
a7bf5b06-e27a-4270-9b30-92141485098e | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP7096
MC7.T14: Vacuum Technology 757Monday: Poster session MOP7096
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, pub... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 0 |
f90b6461-6abd-4a83-a3e9-2bbc34b7711f | Within this constrained envelope, the chamber geometry
was optimized to increase the horizontal aperture while
limiting mechanical stress and deformation. Vacuum con-
ductance, transverse beam impedance, and manufactura-bility were also considered, with the internal cross -sec-
tional area maximized where possible an... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 1 |
043aa76c-4a99-4c4e-bcc7-42e0099914e6 | Corner diame ters 1.4 14
Wall thickness 0.8 1.5
Horizontal aperture 20 22
Rhombic chamber geometries were parameterized using
wall thickness, horizontal aperture, vertical aperture, and
the two internal corner diameters as the main variables. An
elliptical profile was also analysed for comparison. The main ge... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 1 |
6aad6749-2f3d-4bd6-b8fe-5f3542d33096 | rogate model generation, and adaptive refinement of the
optimization front. The resulting solutions provide candi-
date geometries with their corresponding stress, defor-
mation, and parameter sensitivity . An example of the re-
sulting equivalent -stress distribution for a rhombic cham-
ber cross -section is shown in... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 1 |
47cbdf93-2098-4572-9cd3-4b82df412051 | 𝐴𝐴12∙𝑃𝑃1
𝑃𝑃2
where 𝐶𝐶1 corresponds to the 16 mm circular reference and
𝐶𝐶2 to the analysed geometry. To estimate the pressure im-
pact, the gas load was assumed proportional to the internal
wall area and therefore to the perimeter [6]. Since 𝑝𝑝∝
𝑄𝑄𝐶𝐶⁄, the relative pressure scales as:
𝑝𝑝2
𝑝�... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 1 |
ed93bb8d-227e-4727-9123-08d995e136af | geometry form factor, the transverse impedance scales ap-proximately with the inverse cube of this distance , so:
𝑍𝑍
⊥,2
𝑍𝑍⊥,1≈�𝑑𝑑1
𝑑𝑑2�3
.
This estimate is used only as a comparative indicator,
since the real impedance depends on the full chamber shape, material, coating, and frequency spectrum [7].
Manu... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 1 |
c3b7c877-1035-4fc6-aab6-8a882af60313 | atmospheric pressure.
Horizontal apertureVertical aperture
17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP7096
758 MC7.T14: Vacuum TechnologyMOP7096 Monday: Poster session
Content from this work may be used... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 1 |
a1a299ca-4214-4b82-b60d-d5dd75c2de53 | RESULT S AND DISCUSSION
After hundreds of cases, t he optimization showed that
wall thickness is the dominant parameter in the trade -off
between mechanical robustness and vacuum performance.
Within the fixed external envelope, increasing wall thick-
ness reduces stress and deformation, but also reduces the intern... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 2 |
d1e88623-60b8-4395-9275-af3fdf8f434a | the magnet poles, increasing the horizontal aperture con-
strains the internal corner diameters, affecting the mechan-
ical response. It also improves the shadowing of down-
stream components, since the conical absorber tip remains fixed w ith respect to the beam centre while the chamber
wall moves outward, increasing... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 2 |
2cefc948-3bf0-4982-b481-e49c14241344 | only 9.8 mm, well below the 13.1 mm limit associated with
the transverse impedance cri terion
Among the evaluated cases, the selected geometry pro-
vides the largest horizontal aperture considered while
keeping stress, deformation, conductance loss, and the ge-
ometric pressure penalty within acceptable limits. The... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 2 |
eb688f5b-86bd-42ed-bba6-01cc5e1c6749 | crease in the transverse impedance indicator. The conduct-
ance is reduced by only 0.3%, while the geometric pressure
indicator increases by about 10%. Structurally, the maxi-
mum stress is 13 MPa, below the 15 MPa design limit, and the maximum deformation is approximately 3 µm .
PROTOTYPING PROGRAM STATUS
The ALBA... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 2 |
ce21b898-600a-46af-9285-7a20628585cf | integration with the magnet lattice.
Fabrication has progressed, although several manufac-
turing issues have affected the schedule. The QDS1 photon
absorber initially failed to achieve leak -tightness during
brazing, most likely due to a raw material issue in the Glid-cop®. After unsuccessful re -brazing attempts... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 2 |
5205ec04-42f9-4e04-b8fb-0edceddb42e6 | discharge machining, while the QD1 chamber was affected
by a critical electron beam weldi ng issue. These issues led
to delays and required additional process development be-
fore continuing with final fabrication.
The current status is more advanced. For QD1, all indi-
vidual chamber bodies have been delivered and... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 2 |
a676304a-a24f-4732-b3d4-3c8d6ea696ee | checked by CMM. The first chamber section has been
brazed and successfully He- leak tested, while preparation
of the second section for brazing is ongoing. The next op-
erations include brazing of the second section, flange ma-
chining and welding, and the final brazing step of the com-
plete chamber. If the remainin... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 2 |
0f92872e-cd13-4b88-b603-a6e65f95cae6 | date.
CONCLUSION
The ALBA II vacuum chamber design has evolved from
the previously planned 16 mm circular profile to a rhombic
cross- section driven by injection- efficiency requirements
and constrained by the magnet aperture. The selected ge-
ometry provides a 22 mm horizonta l aperture with accepta-
ble mechanic... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 2 |
3387a681-63d0-4810-bf2c-534cd20ee18b | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP7096
MC7.T14: Vacuum Technology 759Monday: Poster session MOP7096
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, pub... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 2 |
d699a0ac-e9a8-4897-b01b-7908c3d093bc | REFERENCES
[1] F. Perez, “ALBA II Accelerator Upgrade Project Status ”,
presented at IPAC’26, Deauville, France, May. 2026, paper
THP2009, this conference.
[2] G, Benedetti el al. , “Status of lattice studies for ALBA -II”,
presented at IPAC’26, Deauville, France, May. 2026, paper
WEP5034, this conference.
[3... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 3 |
aa315e0f-298c-4a77-ab64-52a05ae34b93 | chrotron light source”, in Proc. 12th Int. Conf. Mech. Eng.
Design Synchrotron Radiat. Equip. Instrum. (MEDSI'23) ,
Beijing, China, Nov. 2023, pp. 363-367.
doi:10.18429/JACoW -MEDSI2023 -FROAM02 .
[6] A. Mathewson , “Vacuum System Design ”, presented at
CERN Accelerator School: Vacuum Technology, Geneva, Switzerl... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 3 |
915fde28-e1da-4edd-90f2-73237a0bc5e0 | Mar. 2017, unpublished.
[9] R. Parise et al., “Prototyping for the ALBA II vacuum sys-
tem”, in Proc. MEDSI'25 , Lund , Sweden , Sep. 2025,
pp. 405-408.
doi:10.18429/JACoW- MEDSI2025- THP58 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: 978-3-95450-252-3 ISSN: 2673-535... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7096.pdf | 3 |
d19b40ee-a449-4af0-a0ef-38c1742b8268 | THE BEAM STOPS FOR THE ESS SUPERCONDUCTING LINAC
Elena Donegani∗, Artur Gevorgyan, Anders Olsson
European Spallation Source (ESS), Lund, Sweden
Abstract
For the ESS superconducting linac in Sweden, two types
ofinsertablebeamstopsweremanufacturedinsteadofbulky
beam dumps. The beam stops dump protons either up to
100MeV ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP7098.pdf | 0 |