id
stringlengths
36
36
text
stringlengths
1
1k
source
stringlengths
42
191
page
int64
0
1.03k
7f19e44b-3026-4feb-b92d-e1ef37719f0b
the observed matter-antimatter imbalance in the Universe, known as baryon asymmetry, is one of the most com- pelling[1]. Theunderlyingmechanism,calledbaryogenesis, isanasymmetricprocessthatrequiresCPviolation[ 2]. The baryon asymmetry is quantified by the baryon-to-photon density ratio 𝜂[3]. While the SM predictions a...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
0
4ce65bba-c25a-474a-933e-b7d4cd0dcaad
particlewithrespecttothespinorientation. IntheSMthe EDMs are predicted to be extremely small, but many SM extensionspredictsignificantlylargerEDMsthatcouldbe within or closer to the reach of current and future experi- ments [6]. Since direct measurements of the EDM are ex- perimentallychallengingbecauseofitstinymagnitu...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
0
ee75b3a2-2bfb-4ad9-a562-d4256305edae
electric field. This polarization build-up can be measured usingapolarimeter,asshowninFig. 1. Thespintuneand the Spin Coherence Time (SCT) are two fundamental quan- tities in the EDM investigations using storage rings. The single-particlespintuneisthenumberofspinprecessions around the vertical axis per revolution and i...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
0
af88b4cb-c71a-4baf-bd8d-89dca781a226
thebeampolarizationdecreasesto1/eofitsinitialvalue[ 9]. It must be maximised, within the limits set by the beam lifetimeandthemachineoperation, becauseitdetermines how long the EDM signal can accumulate. To obtain a long SCT, it is necessary to minimise the spin tune spread and, thus, to accurately track the single-par...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
0
9c2ee4c2-e5db-4f97-b054-7876a96b04da
the spin tune spread and, thus, maximise the SCT. In this contribution, the model is applied to the hybrid storage ring, anew-generationdeviceforEDMinvestigationsthatcom- bines electrostaticdeflectors for confinement and magnetic quadrupoles for focusing.17th International Particle Accelerator Conference, Deauville, Fr...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
0
475760ae-8b95-4b32-b9f4-021a9820c8d5
HYBRID STORAGE RING Hybrid[10,11]meansthatitcombineselectricbending elements and magnetic focusing elements. It is a 24-fold symmetric ring with an 800 m circumference, composed of FODO cells, each alternating between straight and bending sections. Each straight section hosts a quadrupole mag- net for focusing, while e...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
1
a06a1ebf-6039-44af-8b13-2813bfa9c0f6
the absence of dipole fields, which can mimic the EDM sig- nal,andthesimultaneouscirculationoftwocounter-rotating particle beams which help control systematic effects. More- over,theelectricfieldprovidedbytheconfinementsystem directly contributes to the EDM signal. Figure 2: Layoutof the hybrid ring lattice. SPIN TUNE ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
1
f10b1f61-08c8-40ff-bcfd-90938ab2458b
tribution are encoded in the first-order coefficients 𝑤𝑖. This term accounts for the effects of the quadrupole fields due to the particle being offset from the reference orbit. On the other hand, 𝜉𝑘accounts for the second-order corrections to thesecontributionsthroughsextupolefields. Thesearethe latticeopticalprope...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
1
476ebb44-2318-4596-a857-df383551bd51
the coupling strengths among them. If the phase-spaces are completelydecoupled,the off-diagonal termsare expected to be negligibly small. Derivation Thestartingpointforthederivationofthespintunemodel is Eq. (1). A more general expression can be obtained from the Thomas–BMT equation at first-order [ 13]: 𝜈𝑠,0= 𝐺𝛾−𝑟...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
1
9c585848-018f-424f-8a0c-c373f3152bed
thisexpressionreferstothereferenceparticle,definedasthe particlethatexactlyfollowsthedesignorbit. Inarealstor- agering,particlesaredistributedinphase-spaceanddeviate fromthereferencetrajectory. Therefore,itisconvenientto introduce therelativespin tune, defined as the deviationof thespintuneofanoff-momentumparticlewithr...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
1
60984b27-24bd-4487-8685-cbdfba5ec975
tupole fields, introduced to correct chromatic aberrations, induce a further dependence through the transverse chro- maticities. This contribution is also linear to first-order, yielding: Δ𝜈𝑠= 𝜎0𝛿+ℎ𝑖𝜖𝑖+𝐻𝑖𝑘𝜖𝑖𝜉𝑘. (6) Uptothispoint,therelativespintunehasbeenconsideredat afixedmomentumoffset. However,inthepre...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
1
efef97b6-83e0-4d4e-8ab5-0be97f5efe2c
where⟨𝛿⟩is the steady-state momentum offset, 𝛿𝑎is the os- cillationamplitude, 𝜔𝐿isthesynchrotronangularfrequency and𝜙𝐿,0istheinitialsynchrotronphase. SubstitutingEq.( 7) intoEq.( 6)andusingtheconstraintimposedbythelongi- tudinalfocusing( ⟨Δ𝑡/𝑡⟩ = 0 ),thesteady-statemomentum offsetaveragestozero. Furthermore,un...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
2
4e4d9dd1-68c0-4734-a9a0-d802a5fc419f
be written as: ⟨Δ𝜈𝑠⟩ = 𝜖𝑖(𝑤𝑖+𝑊𝑖𝑘𝜉𝑘). (8) Thespintunespreadisthereforegovernedbythedependence onthephase-spacevariablesencodedintheterminparen- theses. Tominimisethespread,thesteady-staterelativespin tune must become independent of the phase-space variables to first-order. This condition corresponds to imposi...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
2
8a8c8fdc-7d17-44e2-afd0-02f4516ef96f
lattices providing a third sextupole family. Simulations Thespintunemodelwasfirstusedtodeterminethemodel coefficients. Each coefficient was extracted by isolating the correspondingterminEq.( 2)andsettingtherelevantphase- spacevariable,while keepingallotherdegrees offreedom fixed to zero. Owing to the linear dependence ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
2
83edc45f-b19f-447d-b555-2c9a1593d25f
simulateddata,andcalculatedvalues,obtainedusingEq.( 2). Finally, the residuals, defined as the difference between thesimulated and calculated values, were evaluated to assess thereliabilityofthemodel. SCToptimisationconditionwas validated by tracking a beam of approximately 103particles over106turns in the optimised la...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
2
39c26582-1185-4078-a1af-69ced7ad82f9
bias. Figure 4shows the polarization vector magnitude as a function of time, yielding 𝜏 = (90.6±1.4) s. Figure3: Histogramoftheresidualstocomparesimulated and model-predicted steady-state relative spin tune values. Figure 4: Plot of the polarization vector magnitude as a function of time to evaluate the SCT. CONCLUSIO...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
2
9b23fcd4-d34c-4f75-bced-6d9ada0fb35f
families. Lookingahead,thespintunemodelrepresentsa significant advancement in EDM studies via storage rings.17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-THP4083 MC4.A24: Hadron accelerators: Accelerators and S...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
2
313ce933-6745-4168-9f77-c4cc47d493d2
REFERENCES [1]A.RiottoandM.Trodden,“Recentprogressinbaryogenesis”, Annu. Rev. Nucl. Part. Sci. , vol. 49, no. 1, pp. 35–75, 1999. doi:1/zero.alt4.1146/annurev.nucl.49.1.35 [2]A.D.Sakharov,“ViolationofCPinvariance,Casymmetry, and baryon asymmetry of the Universe”, Uspekhi Fiz. Nauk , vol. 161, pp. 61–64, 1991. [3]E.W.Ko...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
3
bb3f7c0c-56ea-40d7-a76d-8e18bbf78bd9
no. 1, p. 015001, 2019. doi:1/zero.alt4.11/zero.alt43/revmodphys.91./zero.alt415/zero.alt4/zero.alt41 [6]J. Engelet al., “Electric dipole moments of nucleons, nuclei, andatoms:theStandardModelandbeyond”, Prog.Part.Nucl. Phys., vol. 71, p. 21, 2013. doi:1/zero.alt4.1/zero.alt416/j.ppnp.2/zero.alt413./zero.alt43./zero.al...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
3
7cfefd26-6ad1-4b16-a652-1c3750b29f56
Rev. Spec. Top. Accel. Beams , vol. 16, p. 114001, 2013. doi:1/zero.alt4.11/zero.alt43/physrevstab.16.114/zero.alt4/zero.alt41 [10]J. Alexander et al., “The storage ring proton EDM experi- ment”,arXiv, 2022. doi:1/zero.alt4.4855/zero.alt4/arXiv.22/zero.alt45./zero.alt4/zero.alt483/zero.alt4 [11]Z. Omarov et al., “Compr...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
3
db2d4309-e0f7-4b8a-ae8c-53ba676699ae
Rev. Lett., vol. 2, p. 435, 1959. doi:1/zero.alt4.11/zero.alt43/physrevlett.2.43517th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-THP4083 3484 MC4.A24: Hadron accelerators: Accelerators and Storage Rings, OtherTHP...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4083.pdf
3
f92969af-6479-49fe-8488-74ed32be3a52
EVALUATION OF LASER -ASSISTED CHARGE -EXCHANGE INJECTION INTO THE ESSNUSB+ PROTON ACCUMULATOR * A. Opanasenko†,1, N. Milas2, M. Olvegård1 1Uppsala University , Uppsala, Sweden 2European Spallation Source, Lund, Sweden Abstract Laser -based H⁻ charge -exchange injection offers an at- tractive alternative to con...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
0
42788a21-2fba-4a2d-a491-23b92012e61c
lutions of the Schrödinger equation for a two- level model describing the interaction of a relativistic hydrogen atom with a Gaussian pulsed laser beam. INTRODUCTION Laser -based H⁻ charge -exchange injection offers an at- tractive alternative to conventional carbon- foil stripping for injection into multi -mega...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
0
40bb336e-3a14-471b-982f-2084572aa3df
Spallation Source neutrino Super Beam) proton accumula- tor [3]. A THREE- STEP SCHEM E We consider a three -step laser -assisted H⁻ charge ex- change injection into a proton ring without stripping foils [1,2]. The scheme of the beam – laser interaction is shown in Fig.1. It consists of : i) a first magnet -neutra...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
0
285a566f-99cc-4458-a9d7-e5629182ace1
of the atom. Elliptic Gaussian L aser Beam We consider a linearly polarized elliptical Gaussian laser beam that crosses the H0 beam axis at an angle α as shown in Fig.1. T he interaction point (IP) is located at a distance 𝑧𝑧𝐿𝐿 from the laser waist . The vertical component of the elec- tric field , 𝐸𝐸...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
0
9320407a-dd94-44d2-8b56-ce1613f2b64b
angle between the laser and the H0 beam as shown in Fig.1; 𝜎𝜎𝑥𝑥,𝑦𝑦=𝑤𝑤0𝑥𝑥,𝑦𝑦 √2�1 +�𝑧𝑧 𝑧𝑧0𝑥𝑥,𝑦𝑦⁄�2 is the transvers e size of the laser beam at the IP (𝑧𝑧=𝑧𝑧𝐿𝐿); P is the power of the laser micropulse , 𝑤𝑤0𝑥𝑥,𝑦𝑦, 𝑧𝑧0𝑥𝑥,𝑦𝑦, and 𝜃𝜃0𝑥𝑥,𝑦𝑦 is the waist, Rayleigh range, and ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
0
577de116-ba80-43eb-b64b-972add477839
and un correlated) from 𝜔𝜔0 and 𝛽𝛽0 of the reference particle 𝜔𝜔=𝜔𝜔0+Δ𝜔𝜔, 𝛽𝛽=𝛽𝛽0−𝐷𝐷′𝑥𝑥∆𝑐𝑐 𝑐𝑐02𝑐𝑐0+∆𝛽𝛽𝑢𝑢𝑐𝑐 𝑐𝑐𝑢𝑢 𝑢𝑢 . ( 3) ________________________________ ____________ * Work supported by the European Union, P roject 101094628 † anatoliy.opanasenko@physics.uu.se . 17th Int...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
0
140eb893-5825-4707-96b2-42e72f637f08
This leads to the appearance of the Doppler broadening of the absorption linewidth ∆ω′, so that Eq. (2) can be given ω′=ω0+∆ω′, ( 4) where ω0=ωγ0(1 +β0cosα0) is the resonant frequency in the rest frame , ∆ω′ in the linear approximation is ∆𝜔𝜔′≈ 𝜔𝜔 [𝛽𝛽0+𝛽𝛽 𝛽𝛽𝑠𝑠𝛽𝛽0+𝐷𝐷′ 𝑥𝑥𝑠𝑠𝑠𝑠𝑠𝑠𝛽𝛽0]...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
1
7f916a5f-99f6-4039-b53f-eb841ec1eb27
with the initial conditions : 𝛽𝛽1(𝑡𝑡=−∞)= 1, 𝛽𝛽3(𝑡𝑡= −∞)= 0. Here 𝛽𝛽1(𝑡𝑡′) and 𝛽𝛽3(𝑡𝑡′) are the probability ampli- tudes of being in the 1s or 3p state , respectively; Ω𝑅𝑅= 𝜇𝜇1,3 ℏ�2𝑃𝑃 𝜋𝜋𝜎𝜎𝑦𝑦𝜎𝜎𝑥𝑥𝑐𝑐𝜖𝜖0𝜔𝜔0(1 +𝛽𝛽0𝛽𝛽𝛽𝛽𝑠𝑠𝛽𝛽 ) i s the Rabi frequency , 𝜇𝜇1,3=�3 4�3𝑒𝑒𝑎𝑎0 ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
1
d824bf15-976f-42fa-8a78-768e405b2ce0
is the empirical coefficient found from numerical calcula- tion of Eqs. (6, 7). From Eq s. (8, 9) and Rabi frequency definition, we can obtain the power of the laser micropulse in a more general form , compared to the similar one obtained in [ 2] 𝑃𝑃=𝜖𝜖0�ℏ𝑐𝑐 𝜇𝜇1,3�2χ 𝜂𝜂∞𝑙𝑙𝑠𝑠�1 1−𝜂𝜂∞�𝜎𝜎𝑦𝑦𝜎�...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
1
84814c12-32e8-43a8-8fb5-09b48d61d6d4
. (12) Using the obtained analytical relation Eq. (12), for the selected beam sizes at the IP, 𝜎𝜎𝑥𝑥= 1 𝑚𝑚𝑚𝑚 , 𝜎𝜎𝑦𝑦= 0.7 𝑚𝑚𝑚𝑚, we can obtain a family of curves of the efficiency as a func- tion of the power at different valu es of the beam emittance (see the Fig.2). It can be seen that an excita...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
1
9fd92354-1cb5-4b74-8807-16a1c353f07f
to velocity debunching and space -charge forces. This re- quires very high laser energy and prohibitively high aver- age laser power. To avoid this drawback of the long drift space, the “crab -crossing” scheme (CCS) was proposed in [4] (see Fig. 3). Figure 3: Geometry of the crab -crossing collision. The angl...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
1
855b4aa1-1dee-4391-b0a5-8871b63275d7
The dispersion function at the interaction point (IP) can be expressed in terms of the longitudinal position Δ𝑧𝑧 of a particle within the bunch and its relative momentum devi- ation 𝛿𝛿𝑝𝑝𝑧𝑧as 𝐷𝐷𝑥𝑥𝛿𝛿𝑝𝑝𝑧𝑧≈∆𝑧𝑧𝑡𝑡𝑡𝑡𝜑𝜑0. (14) The CCS allows the laser micropulse duration (FWHM) to be reduce ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
2
f3318dbb-a5e0-49d8-817d-58e0fcc851ea
𝑐𝑐02𝜎𝜎𝐸𝐸(0)2+�𝑔𝑔(𝐿𝐿)�������2 𝜎𝜎𝐸𝐸(0)2+𝑔𝑔(𝐿𝐿)������𝑔𝑔(𝐿𝐿)𝑡𝑡𝑡𝑡𝜑𝜑0, (16) where 𝑡𝑡(𝐿𝐿)=�𝜎𝜎𝐸𝐸2(𝐿𝐿)−𝜎𝜎𝐸𝐸2(0), 𝑡𝑡(𝐿𝐿)������=1 𝐿𝐿∫𝑡𝑡(𝑠𝑠′)𝑑𝑑𝑠𝑠′𝐿𝐿 0, 𝜎𝜎𝐸𝐸 is the rms energy spread of the bunch. Figure 4: Energy spread along the L2R line with four cav- ities ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
2
cbe663e0-7c5c-4b9c-af25-5a0f682b2bf6
(13, 14) and achieving 𝐷𝐷𝑥𝑥′=−𝛽𝛽𝑡𝑡𝑡𝑡𝜑𝜑0 to eliminat e the Dop- pler broadening due to the energy spread, we have evalu- ated parameters required for the laser-assisted injection into the ESSnuSB+ accumulator which are summarised in Table 1. It should be noted, the p arameters shown in green indicate ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
2
cdd19b60-002e-4c89-b2c9-3e240e4ec943
𝜎𝜎𝐸𝐸 (MeV) 0.6 2.7 2.7 rms duration, 𝜎𝜎𝑏𝑏,𝑡𝑡 (ps) 27.7 44* 44* rms size, 𝜎𝜎𝑥𝑥/ 𝜎𝜎𝑦𝑦 (mm) 1.0/0.7 1.0/0.7 1.0/0.7 𝜀𝜀𝑐𝑐𝑥𝑥/𝜀𝜀𝑐𝑐𝑦𝑦 (μm∙rad) 0.7/0.33 0.7/0.33 0.33/0.33 𝐷𝐷𝑥𝑥/𝐷𝐷𝑥𝑥′ (m /) 0 / -1.546 9.2/-1.546 9.2 / -1.546 rotation angle 𝜑𝜑0 (deg) 0 32.9 32.9 Laser ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
2
83cc49ab-1b24-4635-87c9-2abf3570634c
power and pulse energy required to estimate the H0 beam and laser parameters suitable for laser -assisted charge- ex- change injection. ACKNOWLEDGMENTS The authors are thankful to Dr. Peter Sal én for fruitful discussions. This project Funded by the European Union, Project 101094628. Funded by the European Unio...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
2
88d12b8e-0c7d-4a72-a9f6-42b0decc9237
with a narrow -band laser” , Phys. Rev. Spec. Top. Accel . Beams , vol. 6, p p. 053501-10 , 2003. doi:10.1103/physrevstab.6.053501 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-THP4084 MC4.A24: Hadron acc...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
2
4634c5d6-a51c-4989-8822-d496d8e97d20
[3] A. Alekou et al. , “The European Spallation Source neutrino super -beam conceptual design report ”, Eur. Phys. J. Spec. Top. vol. 231, pp. 3779–3955 , 2022. doi:10.1140/epjs/s11734 -022-00664-w [4] A. V. Aleksandrov et al. , “A crab -crossing scheme for laser - ion beam applications” , in Proc. NAP AC'19 , ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4084.pdf
3
f10e00d0-7b8a-4ed1-8b60-88073d99aafb
STATUS OF AISHA ION SOURCE AT CNAO S. Marangoni†,1, S. Alpegiani1, E. Bressi1, G. Castro2, L. Celona2, G. Costanzo2, L. Falbo1, S. Gammino2, L. Lanzavecchia1, O. Leonardi2, A. Malinverni1, M. Manzini1, P. Meliga1, R. Monferrato1, C. Priano1, F. Russo2, D. Siliato2, M. Spairani1, G. Venchi1, F. Zanoli1 1Fondazione ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
0
fa928a65-5f4d-4b11-a1cb-d3aada894660
INFN -LNS laboratory, has been installed in order to pro- duce new species that will be interesting both for clinical and R&D purposes. This paper shows the most important results along with the issues occurred and the solutions found during the first phase of the commissioning of the source with helium ions beams....
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
0
92898fac-4015-46b7-93c9-a04f5f7bd442
and carbon ions for daily tr eatments . To generate new ion species, a third ion source called AISHa- CNAO has been installed. This system is based on the design developed at INFN -LNS [1 -2], but it includes several enhancements in- tended to allow continuous operation for several months without requiring mainten...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
0
67a63781-7de1-44ec-a53e-354cd9124aab
approval to generate Helium, Ca rbon, and Oxygen as gas beams, as well as Lithium and Iron as metallic beams. Since AISHa was installed at CNAO, it has primarily been used to produce Helium —commissioning of which is still underway [ 4]—so that Helium beams can eventually be used in CNAO's treatment rooms for pat...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
0
3e90d692-921a-4fa4-bab1-8a165954cd67
trode is used to protect the plasma lens . A DC -bias elec- trode is positioned inside the plasma chamber to increase the plasma density and stabilize the beam extracted current. CNAO is the first centre that experienced a long -term op- eration with AISHa source. For this reason there was not a precise main tenance ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
0
558d1cf9-3df8-46b6-b0d4-c5ea4580f1cb
klystron if the overcurrent lasts for more than 2 seconds. After one month of operations, we observed that the warn- ing occurred more frequently day by day and that some- times the interlock was triggered. Since it was not possible to service the source we tried a cleaning procedure with a high-pressure oxygen flu...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
0
3a07d08c-6869-4eb2-b4b7-632a8f1798d2
________________________________ ___________ † stefano.marangoni@cnao.it 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-THP4087 MC4.T01: Hadron accelerators: Proton and Ion Sources 3489THP: Poster session TH...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
0
ac6b25f8-029b-4966-8958-456a8f626d3b
operation s. Considering that the DC- bias was made of Ti- tanium, a simulation study was performed exploiting SRIM (Stopping and Range of Ions in Matter) software [5] in order to find the best material for the electrode. Consid- ering that the DC- bias voltage is 60 V, simulations were performed with a beam of 0.1...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
1
309b1091-0507-4216-8424-ba3cbab39694
• Titanium Sputtering Yield = 0.0338 (0.1266) at 0.12 keV (0.3 keV). • Tantalum Sputtering Yield = 0 (0.00015) at 0.12 keV (0.3 keV). • Tungsten Sputtering Yield = 0 (0.00001) at 0.12 keV (0.3 keV). A market search was performed for a firm able to pro- duce a DC -bias in Tantalum or Tungsten. All the firms ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
1
cd732099-76ef-46e5-b932-92c656a30779
sent the conditions of injection and extraction during a rapid opening in December 2025. The chamber was clean, but some marks we re still present on the extraction insula- tor. The extraction electrode support has been slightly ad- justed to provide better shielding and further reduce these spots. Figure 2: Th...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
1
2e17838c-2ca5-4423-b6e0-be24c3ccb875
Figure 3: The detail of the AM made Tantalum DC -BIAS (left) and of the plasma chamber (right). Figure 4: The extraction electrode (left) and the movable system of the repeller and ground electrode (right) . The primary drawbacks observed after implementing the new DC -bias were the appearance of oxygen in the...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
1
6e237b65-9444-4e0f-9afa-9dd7e6cf0203
technique or potential errors during plasma chamber clean- ing. Further clarification is expected following the upcom- ing replacement of the DC -bias. SOURCE PARAMETERS The AISHa -CNAO source requires careful adjustment of several parameters to optimise beam current and beam emittance. The extraction system emplo...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
1
efb4e9d8-18ba-47ef-9880-f9eb8b4a1146
ground electrodes that are fixed relative to each other but may be moved longitudinally to modify their distance from the plasma electrode. Fig ure 6 illustrates the impact of var- ying the separation between the plasma and extraction electrodes on both horizontal and vertical emittances, as well as the He2+ curre...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
2
67dd14d9-b6d2-4909-bd3f-382068b8e08c
tom graph) in O3- 008 for different puller positions (on X- axis) at three different solenoid currents. Puller position and solenoid current were set to balance beam current and emittance in both planes. Despite this, transverse beam emittances remained high, causing losses in the LEBT due to space charge effects. T...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
2
9c5ffe2c-b30b-4d40-a0bf-1c87bb5b288a
and without slit s scraping (refer to Fig. 7). Table 1: Beam Parameters Beam Parameter Total With Slits Scraping 𝜖𝜖𝑟𝑟𝑟𝑟𝑟𝑟 ,𝑥𝑥 [𝜋𝜋∙mm·mrad ] 56 54.77 𝜖𝜖𝑟𝑟𝑟𝑟𝑟𝑟 ,𝑦𝑦 [𝜋𝜋∙mm·mrad ] 123 15.66 Current O3 -008 [µA] 3500 1440 Current O3 -016 [µA] 1600 1090 Figure 7: Horizontal (left) and ve...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
2
3756fcf8-948c-4473-8ff1-136834be6f17
lists the typical settings of AISHa -CNAO source. Table 3: Summary of AISHa -CNAO Settings Property Value Injection Pressure [mbar] 2.5∙10-7 Extraction Pressure [mbar] 4.3∙10-8 Cryogenic Magnet s Currents [A] 118/114/111/107 RF Output Power [ W] 400 RF Reflected Power [ W] 16 RF frequency [GHz ] 17.812 ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
2
08a81608-4d1d-45e7-b8ab-d9aee88be9c9
characterization to begin in vitro biological tests. ACKNOWLEDGEMENTS The authors would like to thank the DIAM workgroup of INFN Padua Division for providing the Tantalum DC - bias and also A. Galatà for the useful discussions. 17th International Particle Accelerator Conference, Deauville, France JACoW Publishi...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
2
a1016ec5-fc34-43dd-89cc-cd08bf7ed3c7
REFERENCES [1] L. Celona et al., “Experimental characterization of the AISHa ion source “ Rev. Sci. Instrum ., vol. 90, no. 11, p. 113316 , 2019. doi:10.1063/1.5128631 [2] G. Castro et al. , “Experimental characterization of gaseous ion beams produced with the advanced ion source for hadron- therapy (AISHa) a...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
3
c8d645da-29bd-4d2e-bdea-1cb8cd750b2e
[6] P. Rebesan , “Laser powder bed fusion of refractory materials: A new way to produce components and devices for nuclear physics”, SIF Congress 2022, Il Nuovo Cimento 46 C, article 74, 2023 . doi:10.1393/ncc/i2023- 23074-1 [7] A. Girotto et al. , “Additively manufactured tantalum cathode for FEBIAD type ion sou...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4087.pdf
3
932d53e7-12cf-4435-a492-67f230a79505
RF-KO EXTRACTION AT CNAO FOR CLINICAL BEAMS S. Marangoni , S. Alpegiani , E. Bressi , G. Debernardi , L. Falbo , P. Meliga , C. Priano, G. Venchi , F. Zanoli Fondazione CNAO , Pavia, Italy Abstract CNAO is one of the few hadron therapy centres all around the world that produce both proton and carbon ions bea...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
0
74bcb4a3-2ed3-42c8-b1bd-fc45fb8b0403
present extraction method with the betatron core one. INTRODUCTION The National Centre for Oncological Hadrontherapy (CNAO) in Pavia is one of the few centres worldwide that provides clinical treatments for oncological pathologies with both proton and carbon ions beams. The beam parti- cles are accelerated by a...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
0
94102178-4bde-4754-a014-f5b79c75e8ff
in order to deliver the dose to the patients in a controlled and measurable way. For this purpose a third order reso- nance excited by a sext upolar field can be used: after ac- celeration, beam particles are brought out of the stable re- gion, they become unstable in the horizontal t ransverse phase space until th...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
0
2ee5b461-c3d7-4c74-b285-c68864d03b56
in a multiacceleration regime. Indeed in multiacceleration regimes, after the delivery of beam at a given energy , the remaining beam in the ring is accelerated to a higher energy but the trapping process to pass from coasting to bunched beams is very inefficient . Since CNAO plans to implement multiacceleration,...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
0
77d684ae-fe56-4315-afd6-b3be6e46a077
CNAO clinical requirements. Since 11 th May 2024 proton treatments are performed by RF -KO extraction and since 21st June 2025 also carbon tre atments are performed by RF-KO. This paper will summ arize CNAO RF -KO char- acteristics, a part of which have been already presented in [5], and then it will illustrate bea...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
0
ccb51864-a1d6-4a37-91de-9bb3d261562a
nal must be also AM modulated to match the spread in be- tatron amplitudes, but a purely analytical approach for the voltage ramp [5] is not sufficient to guarantee a uniform distribution of extracted particles over time. It has been implemented a feedback system (“Voltage feedback”) on the RF -KO voltage: at...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
0
79784c1b-85e6-4000-8dd3-76f7dc0787d9
(500 W). The voltage feedback guarantee s a perfect control of beam extracted intensity on the time scale of the voltage feedback; however looking at the spill structure at a 10 kHz frequency a ripple appears due to the synchrotron power supplies ripple. To smooth time spill structure an additional feedback has ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
0
b1bded01-de2e-43e2-bd78-3876202f6308
mental importance for beam extraction. This aspect needed a specific study in using RFKO extraction in real treat-ments due to the way beam is delivered to the patients in CNAO. 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 d...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
0
189150b8-bd9c-4b35-b1a0-b19c1e662280
The tumour irradiation is performed dividing the tumour in spots that are irradiated changing beam energy and the current of two fast kickers (scanning magnets). Figure 1 shows the CNAO HEBT (High Energy Beam Transfer) line that is made up of a first part and five lines: three horizontal lines for treatments ( ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
1
776e54c4-b91c-430c-bf01-2f259ff5532d
first part and indicated in the figure as “chopper magnets”. They can create a closed orbit bump that allows the beam to overpass a dump positioned on the trajectory created by the three dipoles among which the chopper magnets are po-sitioned. For each energy, when the dose delivery system measures that all the nee...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
1
db7178b3-1479-405f-aee0-06bcb53d451c
extraction on the HEBT dump. In other words, when chopper is switched off during beam extraction, RF -KO must "pause" its two feedbacks and manage properly voltage and air -core current . For this reason the commands that PIS sends to chopper power sup-plies are sent also to the RF -KO system. Several solutions ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
1
ddb7aa75-b6f0-4661-bef1-0926f894d6aa
on, if voltage or air -core current were put to zero, there is the possibility to initially increase them linearly to their pre extraction interruption average values before turning on the feedbacks. Beam behaviour has been studied in the cases obtained mixing these strategies for voltage and air core current. T...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
1
5db8bfa0-8754-42e3-93d4-4db5e518a0be
pending on the energy and then increases linearly the volt- age to the previous value in 250 µs. After other 2.75 ms the voltage feedback is turned on. Regarding the air -core cur- rent feedback, it is reactivated immediately after the chop-per c urrent has reached its setpoint. CARBON IONS AND PROTONS BEAM CO...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
1
f7b00493-2423-4a0b-9715-cb11f9bfe817
imum) changes with the energy and it was set between 22 mm and 16 mm for protons and between 12 mm and 4 mm for carbon ions; particular attention has been dedi- cated to the shift of beam barycenter and FWHM during the extraction in the same spill. For both species , RF-KO gave an extraction efficiency always h...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
1
c00f4261-3597-40e9-97e0-0b7f05a2d9dc
RF-KO most of the dose is delivered with 50% inten sity limiting the o ther intensities to few spills. As it is shown in Fig. 2, the improvement in the precision of the extraction intensity delivered is very significant comparing the beta- tron core and RF -KO extraction methods for both protons and carbon ions....
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
1
e95ed4a0-6993-4b67-abc0-84b99e425177
beams at 100 µs but when integrating the intensity profil e at greater times, RF -KO has an evident advantage. Figure 3 shows the comparison of Max/Mean at 10 kHz between betatron core and RF -KO extraction for protons beam at 2⋅109 protons/s and for carbon ions beam at 4⋅107 ions/s. 17th International Part...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
1
06d78f95-ea9d-404b-9ff3-43ddde64d6d5
Figure 2: Measured beam intensities for protons and car- bon ions with betatron core and RF -KO extraction. Figure 3: Comparison of proton and carbon ions beams spill inten -sity uniformity for betatron core and RF -KO ex- traction. PROTON FOR OCULAR TREATMENTS COMMISSIONING A specific tumour that CNAO treat...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
2
498e7869-cb18-4aa5-a8f9-222a7e110615
delivery lasts as little as possible: as a consequence partic- ular attention must be devoted to extraction effi ciency and beam intensity . The electronics of the dose delivery chambers has a sat- uration limit of 20 counts/ µs that gives strong constraints to the maximum number of counts and therefore to beam ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
2
525f2e31-68d9-471a-a9f7-e9acc66d1ad3
missioning has been performed for beam protons in the range 62 .7–89.8 MeV dedicated to ocular treatments. After an optimization of synchrot ron tune, RF -KO frequency and air core current feedback parameters , the maximum inten- sity obtained was a compromise between the highest feasi- ble intensity thanks to th...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
2
797f9bb6-ac22-40ea-8f7c-436b74fd3913
tracted with betatron core and RF -KO. Figure 5: Spill uniformity comparison between betatron core ex -traction and RF -KO extraction protons for ocular treat-ments. CONCLUSION RF-KO extraction has been successfully commissioned at CNAO and beams have been clinically qualified making RF-KO the leading extrac...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
2
52fe472e-7ed7-4953-8773-3da5a89abdb5
doi:10.1016/j.ejmp.2015.03.001 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-THP4088 MC4.T12: Hadron accelerators: Beam Injection/Extraction and Transport 3495THP: Poster session THP4088 Content from this work...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
2
ca14803f-4a58-4789-b561-63c1d746947e
[2] S. Marangoni et al. , “Commissioning of Helium Beams at CNAO”, presented at IPAC’26, Deauvill e, France, May 2026 paper THP4100, this conference [3] L. Falbo , E. Bressi, S. Foglio, C. Priano , “Betatron Core Slow Extraction at CNAO ”, CNAO Foundation, Pavia, Italy . doi:10.18429/JACoW- IPAC2018- TUZGBF3 [4]...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
3
07d38695-c421-40e3-96c4-959fcee9692c
[6] M. Ciocca et al. , “Design and commissioning of the non-ded- icated scanning proton beamline for ocular treatment at the synchrotron-based CNAO facility”, Med Phys ., 2019, vol. 46, no. 4, pp. 1852- 1862. doi:10.1002/mp.133890 17th International Particle Accelerator Conference, Deauville, France JACoW Publishin...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4088.pdf
3
ebb1e7d4-4b05-4882-8414-92a2c3070e8e
IMPLEMENTATION OF MULTI-ENERGY EXTRACTION CONFIGURATIONS AT MEDAUSTRON K. Holzfeind∗, E. Renner, TU Wien, Vienna, Austria F. Plassard, EBG MedAustron GmbH, Wiener Neustadt, Austria Abstract Moving from extracting one single energy per cycle to multipleenergiespromisesimprovementsintimeandpower budgets of medical synchr...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
0
f2d29a26-751f-4b0c-b0c3-9cf58e5b3360
withoneresonantsextupoleandoff-momentumoperation, and differ in how the working point is shifted during the energychangeregardingthetimingofelementrampsand off-momentum contributions. INTRODUCTION The synchrotron-basedion beam treatment andresearch center MedAustron, based on the Proton Ion Medical Ma- chine Study (PIM...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
0
6d8170a6-2caa-47b6-9526-885c5dbd74d0
ionbeammustbeadapted. Nominally,synchrotronopera- tionforpatienttreatmentfollowsthesubsequentworkflow: Multiturn injection and acceleration to the energy speci- fied in the treatment plan, followed by betatron core-driven 3rd-order resonant slow extraction [3] until the prescribed dose is delivered. The process conclud...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
0
bf2714a0-aa2a-4d8c-86cb-29a9ba675097
onecycleofthesynchrotronbyre-accelerationordeceler- ationofthebeamaftereachextractionphase. MEEcould shortenthedurationofpatienttreatmentsignificantlyandre- ducepowerconsumption. Thisproceedingwillreportonthe ∗katrin.holzfeind@tuwien.ac.atcurrentprogressoffirstexperimentaltestsofRFKOMEEat MedAustron. The ongoing studie...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
0
43c79620-2192-424f-a957-2f4b14001808
magnetgradient 𝑘2. Theresonanceseparatesthephasespace inregions,whereparticleperformstableorunstablemotion. The area of the stable region, 𝐴=48√ 3𝜋2 𝑆2(𝛿𝑄)2,(2) isdirectlyproportionaltothesquareoftunedistancefrom theresonance, 𝛿𝑄=𝑄 particle−𝑄resonance,andinverselypro- portional to the square of the normalized...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
0
6ae32cf6-efd0-4be5-bd5a-175b46989fcf
to50mswillbeaddedtotheenergychangedurationasthey are needed for the full resonant sextupole ramp. However, theresonancecanalsobeweakenedinsteadofcompletely turnedoff. Anexampleforonesuchimplementation: When increasing the energy, Δ𝐸 >0, and thus the magnetic rigid- ity𝐵𝜌, while delaying the gradient ramp of the reso...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
0
31702cd6-4343-4a02-aab3-3ebee210b1ce
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-THP4090 MC4.T12: Hadron accelerators: Beam Injection/Extraction and Transport 3497THP: Poster session THP4090 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
0
166c6a49-28bd-4053-b973-6bc0796abde2
of the bending dipoles compared to the ramp of the optic magnets, can be used. While an optics change (b) can easily be implemented, these ramps would require additional time and might cause hysteresiseffectsforcurrentcontrolledquadrupoles,asin- stalledatMedAustron. Method(c)canbeusedtoincrease 𝛿𝑄throughashiftinthebe...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
1
ccd5adbd-cc01-48ec-9871-08e74d3f5c47
ramp simultaneously with the red quadrupole curve. The measurementwillbediscussedfurtherinthesectionMea- surements. Below,weinvestigateoption(d)inmoredetail, i.e. increasingthesizeofthestableareaduringtheenergy changebyintroducingadelaybetweentherampofthedipole and quadrupole magnets. A detailed merit analysis of the o...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
1
180bb088-0e19-4444-80a0-e34fb07f84e5
forallcombinationsofsettingsconcerningthetunedistance 𝛿𝑄≷0andenergy steps Δ𝐸≷0. Whilemostaccelerator components are ramped without delay, i.e. together with thebendingdipoles(Fig.1(a))changingthestartingpoint of the gradient ramp of the focusing quadrupoles (Fig. 3), ensuresanincreaseofthestableareabetweentheextract...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
1
ec1ca7b9-ac1a-4f59-9c0e-49314ab6cc0e
210MeVu−1; red dashed line: 𝐸kin=210-200MeVu−1 for12C6+-ions in a modified PIMMS lattice. In the real machine thelinear rampof theresonant sextupoleincludes round-offs, which are currently not present in the Xsuite model. Figure 2: Integrated field for the bending dipoles and one quadrupole family for an energy change...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
1
9c513ed1-02ca-4510-9205-face71b36dc1
tupole𝑘2=8.5 m−3. Furthermore,thebeamwasinitialized asamatched,bunchedbeamwithinanRFbucketwiththe momentumoffset 𝛿=−2.8×10−3,voltage𝑉=2650 V and RF frequency 𝑓RF=(1−𝜂𝛿)×𝑓 0=2.26 MHz , where𝜂 is the slippage factor and 𝑓0the on-momentum revolution frequency. The simulation used time-dependent settings, withthed...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
1
04bd7726-f538-4b5e-9025-6feab483934e
Figure3: Evolutionoffocusingquadrupolestrength 𝑘1,fdue to(a)delayedor(b)advancedgradientramps;modifiedto ensure an increase of the stable area for combinations of positive and negative tune distances Δ𝑄and energy steps Δ𝐸. The corresponding𝐵𝜌-ramps are shown above. Figure4: Comparisonofparticledistributioninnormal...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
2
147b1204-b312-476a-81a6-62b1cb377465
Kobayashi-Hamiltonian [9,10] is used to calculate the sepa- ratrixes,indicatingthesizeofthestablearea. Thedifference in the stable area from before the ramp (blue) to the high- est tune distance (in red) is clearly visible. At the highest diversionof𝑘1(★inFig.3(b))fromthematchedextraction settings the tunes are shifte...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
2
12114e04-70fd-478a-9ca1-0d827efdba8d
gradientand 𝐵𝜌-rampof𝐵𝜌(𝑡+Δ𝑡) 𝐵𝜌(𝑡)=1.0016. Equation (4) showsgoodagreementbetweenestimationandtrackingand canthusbeusedtocalculatetheneededdelay/timeadvance Δ𝑡for the desired tune change. Measurements In a first measurement campaign three energy steps of Δ𝐸=4 MeV u−1wereperformedforcarbonionbeamsstart- ing ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
2
6ea802a7-c303-4efb-b063-3158a6115c51
in Fig. 2 for the first energy step. While further analysis and measurements are needed, tune measurements with a Schottkymonitor[11],indicatethatthetunereturnstothe initialvalueafterthefullramp. Duringtheenergychange, specificallybeforethebendingdipolesstarttheirramp,as shown in Fig. 5, a tune shift of Δ𝑄𝑥≈1.1−1.2×1...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
2
054f82e8-ba49-4c1d-a1cb-04f029c1a9b8
energychangesformulti-energyextractioninionbeamther- apy. We present a proposed workflow, validated through Xsuite simulations, along with initial measurements at MedAustron. Over the next year, we plan to expand this approach and integrate it with RFKO extraction of bunched beams.17th International Particle Accelerato...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
2
c0fb4913-c122-483a-8556-661f12162626
ACKNOWLEDGMENTS The financial support of the Austrian Ministry of Educa- tion,Science,andResearchisgratefullyacknowledgedfor providingbeamtimeandresearchinfrastructureatMedAus- tron. Furthermore,IwouldliketothanktheTBU,NCR,and OPS departments at MedAustron, as well as the accelerator group at TU Wien for their support ...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
3
43352099-798a-40e7-b4c3-ea1655c51c0c
2846932 [4]K. Nodaet al., “Slow beam extraction by a transverse RF fieldwithAMandFM”,Nucl. Instrum. Methods Phys. Res., Sect. A, vol. 374, no. 2, pp. 269–277, 1996. doi:10.1016/0168-9002(96)00096-4[5]A. D. Francoet al., “Slow Extraction Optimization at the MedAustronIonTherapyCenter:ImplementationofFront End Accelerati...
D:\Daily_ihep\Conferences\IPAC2026\THP\THP4090.pdf
3