id
stringlengths
36
36
text
stringlengths
1
1k
source
stringlengths
42
191
page
int64
0
1.03k
d2ed1e17-191b-4e61-899e-d3f2fe5e4feb
space manipulation, beam -loading dynamics, and plasma density tapering to meet these specifications while main-taining stable operation. Recent experimental and simula- tion research for high-quality electron beams with energies around 500 MeV indicates that plasma densities between (2–5) × 10¹⁸ cm⁻³ offer an opti...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
1
a21dc88d-a8de-4b06-8a31-5715a2a0d49b
crucial control parameter that influences both the injection threshold and beam -loading strength . It was demonstrated experimentally that shock -front injection, combined with laser self -evolution effects, actively leverages beam load- ing to optimise the final phase -space distribution, allowing the acceleration...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
1
d9a790a6-f2b6-4cbe-aba6-e6fe617aac60
to Phase -1 include: development of robust gas-jet and gas - cell waveguide/capillary technologies for cm -scale plasma channels; demonstration of acceleration stability and re- producibility at 100 Hz; preservation of sub -0.5 mm·mrad emittance during long -channel acceleration and plasma- to- vacuum extraction; a...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
1
c25c3830-be86-46ab-b516-ce6141bceec5
R&D challenges. The ReMPI scheme promises excep- tional beam quality in simulations —with normalised emit- tances well below 0.35 mm·mrad and slice energy spreads at the 10⁻3 level — with a bunch charge of 10 pC and a 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-9...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
1
053a66d6-14cf-4fc3-8ee1-ca0de4990da2
bunch duration of 350 as , but requires experimental vali- dation of the resonant multi -pulse driver and synchronisa- tion of the ionisation pulse. Continued optimisation and ex- perimental campaigns will determine which approach best balances beam quality, stability, and operational comp lex- ity for the EuPRAXIA -E...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
2
2b92ae7f-40f9-4f2b-a2a5-e1b60ce4bd84
block employs a permanent -magnet quadrupole (PMQ) tri- plet placed immediately after the plasma exit to intercept the divergent beam before emittance blow -up [13]. The large projected energy spread (at the per cent level) induces strong chromatic aberration, leading to significant beam halo formation and a resulting...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
2
636df16a-3974-49f1-ac0d-f1d3aae96902
distinct FEL physics, a bunch- decompression chicane was propose d to stretch the bunch longitudinally, converting correlated energy spread into bunch length and thereby re- ducing the slice energy spread at the cost of reduced peak current [17]. To align the electron beam properties with the undulator's focusing ...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
2
9278e745-927c-42f1-89ed-f7beffffc5d9
spatial resolution [20]. Normalised emittance can be meas- ured using single -shot “incoherent OTR” screen tech- niques at dedicated diagnostic stations before and after the chicane, as well as with an electron -beam spectrometer. Timing diagnostics preserve the sub -femtosecond intrinsic synchronisation between ...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
2
6e5341ae-80bc-49e0-ae3e-347072f984c1
using a single -shot approach [21]. Undulator L ine The EuPRAXIA -ELI ERIC facility adopts hybrid per- manent -magnet undulator (HPMU) technology for both Phase -0 (EUV) and Phase -1 (soft X -ray) FEL operations, leveraging the proven performance and field quality demonstrated by the Swiss -FEL program [2 2]. For...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
2
39f9c1d2-8a29-42bf-a036-e6b46533d96f
shimming, and pole tuning during fabrication and commis- sioning [22]. The undulator line employs permanent -mag- net phase shifters between segments to maintain longitudi- nal phase coherence across the operating gap range, with magnetic shielding to prevent crosstalk between adjacent devices, as well as a single ...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
2
cd4624a3-265d-4561-8b11-3915411674ae
ERIC FEL is designed following the proven architecture of the FLASH facility at DESY [23], adapted to the specific requirements of laser -plasma accelerator (LPA) driven FEL operation in the EUV (Phase -0) and soft X -ray (Phase -1) regimes. The beamline layout follows the canonical FLASH arrangement: undulator exi...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
2
7f4b2d40-6733-4f85-a249-55ccd1f878b1
monochromator (PGM) for EUV wavelengths, while Phase -1 requires a time -delay -compensated double -grating monochromator design to preserve femtosecond pulse du- ration across the water -window range [25]. For Phase -0 commissi oning (2028 -2029 ), the facility will deploy one primary beamline serving the 30 -40 n...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
2
b1fda288-520c-4e8b-b410-b01b42f600e6
The beamline design prioritises mitigation of radiation damage through grazing -incidence optics, gas attenuators for pulse -energy control, and distributed diagnostics for measuring pulse energy, wavelength, wavefront, and arri-val time [26]. 17th International Particle Accelerator Conference, Deauville, France JAC...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
2
df8eb790-de96-4012-a965-39c60b3ff9fa
SECONDARY SOURCES FOR ULTR A- FAST SCIENCE Betatron Radiation Source Betatron X -ray emission arises when relativistic elec- trons trapped in the laser -driven plasma wakefield (blow- out regime) undergo transverse betatron oscillations within the plasma bubble and radiate broadband, synchrotron -like photons [...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
3
6c0e16c7-8dbd-4250-9531-e4aa6c0d6e63
of ~ a few fs to sub -100 fs [30]. The beam is forward -di- rected with mrad -scale divergence [27] and exhibits partial spatial coherence sufficient for propagation -based phase - contrast imaging [31]. In the case of the 1 GeV electron beam energy , hard X -rays (cut-off energy of ~50–100 keV) enable dense matt...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
3
6300f820-4081-4ca9-9fd0-e7fc979215cb
pact, high -repetition -rate positron source that exploits la- ser-wakefield acceleration (LWFA) of electrons to tens of M e V, followed by Bethe –Heitler (BH) pair production in a thin, high -Z solid converter [32]. This approach combines the ultrashort pulse structure and high peak brightness of laser-plasma so...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
3
e7f418f9-c675-4646-b51c-30b75d7ec972
mising converter thickness, material composition, and multi -layer approaches to maximise yield and beam qual- ity [33], as well as designing dedicated beamlines to guide and select positron beam parameters for specific applica- tions. As high -repetition -rate LWFA technology matures and average laser power increa...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
3
65164be3-3ab2-47c0-95a9-84fe84dbd7ed
kHz laser -driven positron source at EuPRAXIA -ELI ERIC represents a significant step toward compact, high -repeti- tion-rate secondary sources for material science and funda- mental physics. CONCLUSION The EuPRAXIA -ELI program leverages ELI Beamlines' established infrastructure, operational experience with la- se...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
3
b7be1138-8494-4e59-9805-3d2cc30733f1
and structural biology that remain challenging for conven-tional large -scale facilities . The EUV LPA -based FEL setup at ELI Beamlines is expected to be commissioned in 2028 -2029 . The soft X -ray water -window LPA -based FE L setup should be commissioned by 2031. The betatron setup at ELI Beamlines, based on t...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
3
343723e2-78ae-4b11-8ef6-22fd19aa0ca0
SWISSELITE, grant number 8K2501) financed by the Swiss -Czech Cooperation Programme. REFERENCES [1] E. Prat et al ., "A compact and cost -effective hard X -ray free - electron laser driven by a high- brightness and low -energy electron beam," Nature Photonics , vol. 14, pp. 748–754, 2020. doi:10.1038/s41566- ...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
3
31c2e6ff-c0aa-474f-89c2-2c245773aa83
linear colliders," Phys . Review Spec. Top. Accel . Beams , vol. 13, p. 101301, 2010. doi:10.1103/PhysRevSTAB.13.101301 [5] W. Wang et al., "Free -electron lasing at 27 nanometres based on a laser wakefield accelerator," Nature , vol. 595, pp. 516– 520, 2021. doi:10.1038/s41586- 021-03678-x [6] S. K. Barber...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
3
ba2ca861-3224-46cf-91e0-94648123c5e8
[7] Z. Jin et al., “Optimized laser wakefield acceleration: Gen- erating stable, high-energy, monoenergetic electron beams and demonstrating extreme -ultraviolet free -electron lasers”, Phys . Rev. Res. vol. 8, p. 013207 , 2026. doi:10.1103/qvg7- ng8n [8] C. Labat et al., “Seeded free- electron laser driven by a c...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
4
0e58b8c5-3187-4ad5-8fd4-7a9b78fa7240
AIP Conf. Proc. , vol. 1228, pp. 11–32, 2010. doi:10.1063/1.3426041 [12] A. Molodozhentsev et al., "Laser plasma accelerator -based soft X -ray FEL development at ELI -Beamlines," in Proc. I PA C ’23, Venice, Italy, May 2023, pp. 1831 -1834. doi:10.18429/JACoW- IPAC2023- TUPL032 [13] M. Migliorati et al ., “...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
4
9073a69f-750c-455a-9ce6-bac34f537695
doi:10.1038/s41598- 025-24672-7 [16] R. Pompili et al., “Experimental characterization of active plasma lensing for electron beams”, Appl . Phys . Lett., vol. 110, p. 104101, 2017. doi:10.1063/1.4977894 [17] A. R. Maier et al ., “Demonstration scheme for a laser - plasma -driven free -electron laser”, Phys . Rev....
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
4
1c273c29-5572-42cf-bcd6-ff3de2246be4
accelerators”, Rev. Mod. Phys ., vol. 90, 2018. doi:10.1103/RevModPhys.90.035002 [21] K. Jiang et al., “Measurement of electron beam transverse slice emittance using a focusing beamline”, High Power La- ser Sci . Eng., (2023), vol . 11, no. e36, 2023 . doi:10.1017/hpl.2023.9 [22] C. J. Milne et al., “SwissFEL: t...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
4
1cfd9784-7d31-48a0-a8a7-17d3a91857f3
[25] N. Gerasimova and V . Dziarzhytski, "The monochromator beamline at FLASH: performance, capabilities and upgrade plans," J. Mod. Opt., vol. 58, no. 16, pp. 1480–1485, 2011. doi:10.1080/09500340.2011.588344 [26] B. Keitel et al. , "Hartmann wavefront sensors and their ap- plication at FLASH," J. Synchrotron...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
4
c611f96c-215d-4023-abb8-b197c685ed80
ultrafast hard X -ray Science”, Photonics , vol. 9, no. 11, p. 853, 2022. doi:10.3390/photonics9110853 [30] A. Rousse et al. , "Production of a keV X -ray beam from synchrotron radiation in relativistic laser -plasma interac- tion," Eur. Phys. J. D , vol. 45, no. 2, pp. 391– 398, Nov. 2007. doi:10.1140/EPJD/E2...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
4
5ffd6e1f-fdd1-46d1-87a9-4c592d22ab45
yields using multi -layer targets irradiated by laser -induced energetic electrons ,” Front . Phys ., vol. 10, p. 1038416 , 2022. doi:10.3389/fphy.2022.1038416 [34] M. J. V. Streeter et al., “Narrow bandwidth, low -emittance positron beams from a laser -wakefield accelerator”, Sci. Rep., vol. 14, no. 6001, 2024...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M02.pdf
4
61793522-6095-400e-9cd0-f61047862368
CLARA COMMISSIONING AND FIRST FRIENDLY USER EXPERIMENTS D. Angal-Kalinin∗1,2, M.A. Johnson1,2, J.K. Jones1,2, and T. Pacey1,2, on behalf of the CLARA Team 1ASTeC, STFC Daresbury Laboratory, Sci-Tech Daresbury, Warrington, UK 2The Cockcroft Institute, Sci-Tech Daresbury, Warrington, UK Abstract TheCLARAfacilityatDaresbu...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
0
6457426f-876d-4c86-a3b8-cf416064e989
including: advanced diagnostics measurements using coher- enttransitionradiation(CTR)andopticaltransitionradia- tion (OTR) stations; Very High Energy Electron (VHEE) cancer-therapy studies; beam-driven plasma wakefield ac- celerationstudiesrelatedtonextgenerationcolliders. These experiments exploited the full capabilit...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
0
329942c4-4981-4457-92ee-90c5bfacf9f8
Applications(CLARA)isahigh-brightnesselectronbeam test facility at STFC Daresbury Laboratory. The layout of the accelerator facility is shown in Fig. 1. The CLARA front end, comprising a 2.5-cell S-band 10Hzgun followed bya2mS-bandlinac,wasmadeavailableforusersintwo dedicated experimental runs from 2018 until 2022 [ 1]...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
0
60ea1c67-a971-4378-add0-94c0736dfcc5
final beam dump in October 2025. Beam commissioning progressed alongside technicalsystemscommissioning, and included the testing and deployment of many high-level softwareapplicationsforsettingandcharacterisingthebeam parameters. Table 1summarisesdesignbeamparameters ∗deepa.angal-kalinin@stfc.ac.ukTable 1: Design CLARA...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
0
2dd834a5-4199-42fb-b9b5-83f9d1cdb4ad
laborationwithusers. Beamwassuccessfullydeliveredto multipleexperimentsfromJanuarytoApril2026. Thispa- perdescribestheupgradeofCLARA,highlightsfrombeam commissioning, and a brief description of beam delivery to the five user experiments. CLARA UPGRADE The swap of photoinjector gun; installation of three ad- ditional4mS...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
0
55d9ede3-1db5-4509-ab3f-c599f28791b7
separately-shielded enclosure where the majority of user ex- periments take place [ 2]. Installation of the FEBE beamline was completed in parallel with beam commissioning activi- ties in the main accelerator hall. The installation and Site AcceptanceTest(SAT)ofthe 120TWlaserwerecompleted in November 2025 with the lase...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
0
e4f23ed2-4de2-4d35-9a44-1fcf80a0b0ab
beamdumpinApril2025;furthertransportthroughFEBEto thefinalbeamdumpfollowedinOctober2025. Theexisting17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUO2M05 1128 MC2.A08: Photon sources: Linear AcceleratorsTUO2M05...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
0
021bdb3b-d1eb-4e2c-8c73-48681a5723d8
Figure1: SchematicoftheCLARAlinearacceleratortestfacility,includingtheFEBEbeamline,andshieldedFEBEhutch. The 120TW laser systemis situated abovethe FEBE Hutch. CucathodewasreplacedwithaCs 2TecathodeinSeptember 2025,followingadedicatedin-houseR&Dprogramme. This newcathodedeliversthedesignbunchchargeof 250pCat arepetitio...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
1
f85cdb56-b007-4c44-b1bd-768de3beee5a
andafterRFconditioningupto 1.25µspulselengthandgra- dientsof∼95MV/m ,both cathodes demonstratedeffective QEsof∼10%–12%. Thefirstcathodewasremoveddue to significant visible ‘spotting’ on the surface [ 9], though later studies showed similar spotting on the current cathode. However, significant QE degradation has not bee...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
1
a3d87d86-2ca3-4a87-b9ff-aa0f7f36ae21
techniqueisusedforhigh-resolutionmeasurementsofthe beam’s transverse phase space [ 11]. A normalised emit- tanceof< 1µmistypicallymeasuredforthe 35MeVbeam produced by the CLARA front end. The emittance of the full-energy ( 250MeV) CLARA beam can vary significantly dependingonthebeamparametersrequiredbyusers. Foran unco...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
1
b39545ca-60e1-4ba8-8a94-6fc835abb07d
space; howeverthe 4HC is currentlyundergoingRF condi- tioningafterwaveguidevacuumissues, andwasunavailable for first experiments. The FEBE arc is non-isochronous, with a nominal 𝑅56of+7.7mm; for maximum compres- sion in FEBE, the VBC must therefore operate in an over- compression regime. Bunch length diagnostics inclu...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
1
3c7c957e-6b31-4832-ab76-6ee27802fe69
that appears as a variation in energy density in the bunch, and can be tuned by varying the compression ratio. The origin of this effect is poorly understood and will be a focus of the upcoming machine development period on CLARA. Software Development AcornerstoneoftheHigh-LevelSoftware(HLS)develop- mentonCLARAhasbeent...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
1
27d2e56a-0206-41ec-8adb-801ef4bd62cf
PUMBAextendsthis furtherbyautomating multi-steppro- cedures, data collection and alert handling. Applications builtonthesecomponentsrangefromtheeveryday(opening valves,crestingRFcavities)toadvanceduserexperiments (robust dose delivery, and performing multi-dimensional parameter scans with multi-diagnostic acquisition)....
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
1
28667743-4807-4f13-9d3a-e7830b4ec9ae
CombiningCATAP,LAURA,andPUMBAwithastart- to-end simulations framework [ 16] (SIMBA) and a soft- IOC generator (SARABI) results in an integrated digital shadow[17,18],asteptowardsafulldigitaltwinthatreflects thephysicalmachine,allowingadvancedoptimisationand HLS development without impacting machine operations. CLARA ha...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
2
b687ef83-f769-419b-9cf0-3486aa3e9015
were picked on the criteria of: stakeholder engagement; the needtodevelopexpertisein settingupvariedandcomplex experiments. Five different experiments (two of these in- cludingadditionalsub-experiments)werechosencovering advanced diagnostics, medical applications and novel ac- celeration. All seven experiments were hig...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
2
64adc953-1383-4791-a976-a2f26f7d4dc3
measurements were benchmarked against quadrupole scans usingCLARA YAGscreens. The capturedimagesof spa- tially coherent OTR demonstrated a minimum beam size of less than 30µm at 250MeVand 250pC. Coherent Transition Radiation (CTR) DESY Anexperimenttooptimisethecompressionoflowcharge beams on CLARA and to demonstrate <1...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
2
1446284c-0154-4636-b7a4-3406dd2a0bc9
wasobservedonthecamera,andthephotodiodesresolved sections of the CTR spectrum; the results suggest bunch structure at < 5fs. VHEE - Scattering CERN/University of Oxford/John Adams Institute Dual scattering foilswere designed and installed in the sec-ondFEBEexperimentalchamber(in-air)togeneratelarge (∼1cmRMS), uniform b...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
2
0a5e34c5-9d0b-4c74-b59e-a7e4080ce2f8
Firstly, dose measurements using Gafchromic films were taken at several depths within a water phantom and com- pared with Monte Carlo simulations based on the measured ICT bunch charge and transverse beam profile measured on a YAG. Secondly, lung cancer cells were irradiated in Eppendorf tubes. Conventional dose was de...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
2
9b0db864-1db0-4dcd-b9e4-6e42a644dfef
plasma(using 16kVHVwithargon,cellpressure ≈10mbar, continuous gas flow) was successfully demonstrated. A highly compressed 250MeV drive beam wasused to gener- ate and sample decelerating gradients up to 1GV/m. Sec- ondly, studies into non-linear plasma lensing (Ar and He) withthissetupwerealsoperformed,whichwillbecruci...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
2
2b2e4527-344e-4ea1-a929-79c9c7734ba8
team at Daresbury Laboratory and we thank them all for their work on the design, installation, beam commissioning and software development for CLARA.We would like to thankourfriendlyusersfortheircollaborativeworktosetup and commission their experiments with CLARA beam.17th International Particle Accelerator Conference,...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
2
ac18113b-5a83-4c93-a0c0-ace8675be850
REFERENCES [1]D. Angal-Kalinin et al., ”Design, Specifications, and First Beam Measurementsof the Compact Linear Acceleratorfor Research and Applications Front End”, Phys. Rev. Accel. Beams,23, 044801, 2020. doi:1/zero.alt4.11/zero.alt43/PhysRevAccelBeams.23./zero.alt4448/zero.alt41 [2]E.W.Snedden etal.,”Specificationa...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
3
d18448ce-4d32-4e39-8f88-8e45375a518f
Deauville,France,May2026,paperWEP6104,thisconfer- ence. [5]M. Kinget al., ”Automated RF Conditioning on CLARA”, presented at IPAC’26, Deauville, France, May2026, paper WEP6171, this conference. [6]T. Paceyet al., “Commissioning of the CLARA facility: sta- tusupdateanddiagnosticsperformance”,in Proc.IBIC’25 , Liverpool,...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
3
0d4168ff-1665-4f23-8312-6454132156c5
odestotheCLARAAcceleratoratDaresburyLaboratory”, presented at IPAC’26, Deauville, France, May2026, paper THP2143, this conference. [9]A. Pollard et al., ”Evidence for RF Breakdowns Causing Sur- faceAnomalieson CaesiumTelluride Cathodeat CLARA”,presented at IPAC’26, Deauville, France, May2026, paper TUP3075, this confer...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
3
9f22033d-ff39-4549-8605-977c37bd0f52
[12]M.A.Johnson etal.,”TransversePhaseSpaceTomography at CLARA Using Generative Machine Learning”, presented at IPAC’26, Deauville, France, May 2026, paper WEP6092, this conference. [13]J.K. Jones et al., ”Compression and Linearisation Studies on CLARA”, presented at IPAC’26, Deauville, France, May 2026, paper THP2100,...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
3
4498ab12-b2fc-4e4a-b943-630798d8fa35
Framework for Particle Accelerators Based on a Compre- hensive Lattice Description”, arXiv Preprint , 2026 doi:1/zero.alt4.4855/zero.alt4/arXiv.26/zero.alt44.191/zero.alt43 [17]A.Brynes etal.,”MoonlightontheSerengeti: Casting(Digi- tal) Shadows with NALA, SIMBA, PUMBAA and Friends”, presented at IPAC’26, Deauville, Fra...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
3
cc8430b1-9a7e-4091-8175-fa5cb5060e4a
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUO2M05 MC2.A08: Photon sources: Linear Accelerators 1131: MC2 : Photon Sources and Electron Accelerators TUO2M05 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribu...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M05.pdf
3
742cf4eb-1316-4eeb-882f-943233274f62
SLS 2.0 COMMISSIONING PROGRESS M. Aiba, PSI Center for Accelerator Science and Engineering, Villigen, Switzerland on behalf of SLS 2.0 Team Abstract Commissioning of SLS 2.0, the first light-source storage ring employing a substantial number of permanent mag- nets, began in January 2025. The nominal beam current of 400...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
0
0dcd694c-ac3e-485b-a512-ac817fd4a947
lessonslearned,andexperiencegainedduringtheinitialuser operation. INTRODUCTION The new storage ring at the Swiss Light Source (SLS), known as SLS 2.0, was successfully commissioned in 2025. Itisthefirstlight-sourcestorageringtoemployasubstantial numberofpermanentmagnets torealize acompact multi- bend achromat lattice: ...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
0
99527b9d-23f1-4fbb-9685-4d533baa6cfb
external users. This paper highlights major commissioning progress achieved after the first three months, together with early user operation experience. The key parameters of SLS 2.0 are summarized in Table 1for reference. Table 1: KeyParametersof the NewSLS StorageRing Parameters Values Beam energy 2.7 GeV Circumferen...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
0
7b7f97b3-28da-4d39-bc36-0e4e0030bebd
implemented in the control system. Characterization of the installed IDs is ongoing [ 4], and additional feed-forward tables are being developed to mitigate optics distortions. Thefirst light at each beamline was typically achieved within one day, allowing the subsequent mandatory radia- tion survey in the optical and/...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
0
99a668de-310d-4e94-a363-5eee817ce5db
isplanned. Weencounteredaseriousvacuumpressureissue with a 2-meter-long APPLE-type undulator with a 9-mm inner-diameter vacuum chamber. Due to the proximity of theundulatorpermanentmagnets,theNEGcoatingofthe chambercouldnotbeactivatedin-situ,andwereliedonlyon beam vacuum conditioning for this short chamber. Vacuum cond...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
0
1fa3bf7f-5b06-47a7-9a2c-3babe91c2b78
orbit feedback system [ 6] was taken into operation. The feedbackisimplementedintheFPGA(programmablelogic) part of a Multiprocessor System-On-Chip (MPSoC) that receivesbeampositionmonitor(BPM)dataviadedicated multi-gigabitfiberopticlinks,usinganin-houselow-latency protocol. The same protocol and fiber links are used by...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
0
906f3a90-19a4-4c09-ab56-6703af2f0cf8
Regarding beam stability, stabilization of the RF voltage and phase is also essential, and the digital low-level RF system[7]playsakeyrole. Theparametersoftheinternal feedback loops were optimized to minimize RF voltage and17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
0
1ca9b1fa-8eac-485b-a7c8-f299328043a3
Figure1: Frequencyspectrumofbeamjitteratareferenceout-of-loopBPM.Integratedvaluesupto40kHzarealsoshown. The two prominent peaks correspond to 50-Hz mains and 90-Hz girder eigenfrequency. Stability estimated using all BPMs was 144 nm and 91 nm in the horizontal and vertical planes, respectively. phasejitters,aswellasorb...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
1
aa1192aa-18b2-48a8-a73d-1868ed14f5aa
potentially requiring mitigation measures. Tune feedback system is, so far, not required; the tunes remainessentiallyconstantwithinastablerangeoverseveral days,andoccasionalmanualadjustmentsaresufficient. This medium-term tune stability is attributed to the fact that both the closed orbit and the linear optics are prim...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
1
87628c73-cd30-46f9-9b60-7cc48da56bf6
realignmentcampaignwaslaterrequiredasdiscussedearlier. The girders are motorized, allowing remote alignment in theverticalplane. Wethereforealignedallgirdersvertically to the reference mid-plane ( 𝑦 = 0). The storage ring and beamlineswillthuslieonacommonreferenceplaneonce the beamlines are aligned accordingly. In the...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
1
0b0d2eb1-89a2-4fd8-8fad-85b4220cf301
cations around the ring [ 3]. The source of the dipole errors responsible for this effect could not be identified; therefore, theissuewasaddressedbyshiftingcombined-functionmag- nets to introduce a compensating dipole component. The orbitcanbefullycorrected, afterthealignment,withinthe dipole corrector capacity up to 6...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
1
5cdb5e78-80dc-4b4c-b1db-ef07f274494d
cause serious damage. Our primary concern is the very thinvacuumchamberwalls(0.5–1.0mm),whichcouldbe punctured and lead to a vacuumleak in the worstcase [ 10]. To avoid such critical failures, a dedicated beam dump kickerandaninternalbeamdumpareinstalled[ 11]. Thema- chineprotectionsystem,integratedintotheinterlocksyst...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
2
7ec0fec5-9b88-47d7-8138-8128e216aa1b
injection septa and kickers. A high injection efficiency of >90% is routinelyachieved, despite the limited acceptance, owing to the thin septum (1 mm blade) [ 12] and the emit- tanceexchangein the booster[ 13]. The beam loss monitor system [14] proved highly useful for injection tuning. Since the pulsed magnets are ope...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
2
36992f37-31b3-480e-bd35-6dbdcfdd73ea
tothe storedbeam. However,it iswellknownthat thecon- ventionalinjectionschemeusing bumpkickersis notideal, sincetheclosed orbitbump cannotbe perfectlyrealized in practice. This is further discussed in the nextsection. The linear optics is corrected within the quad corrector capacityupto70%. Thenonlinearopticsisoptimize...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
2
474bebe8-c9cd-4d52-8c16-8e72da9c3fc3
sign, whichassumed aconstantpressure of 10−9mbardom- inated entirely by carbon monoxide molecules: the actual residual gas composition indicates a significant contribu- tionfromlighterspecies,andtheaveragepressurecanreach below10−9mbar. Empiricaloptimizationofthenonlinear opticsmayalsocontributetotheimprovedlifetime. A...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
2
ff651262-7d06-46dc-aa5b-56f01fa63e3c
Two-week pilot operation with friendly users was carried outinsummer2025,whilethefirstnormaluseroperation was conducted in November–December 2025, during which twelvebeamlineswereoperational. Gratifyingoperational statistics were obtained, as summarized in Table 2. More detailsoftheinitialuseroperationcanbefoundinRef.[...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
2
a125cdcb-99c7-494a-92cd-499963d413cb
(Dec. 2025–Mar. 2026), which can generate a vari- able, high peak magnetic field to provide high-energy photonsfordipolebeamlines. However,themagnetsdidnot passthesiteacceptancetest,asnotallconductorsreached thesuperconductingstate. Asaresult,theinstallationhadto be postponed to late 2026. After intensive investigation...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
2
77a917e1-eb77-4119-bfb4-16cc63aff35d
improved by applying ex-situ bake-out, installation under neongasatmosphereandfurtheraweek-longin-situNEG activationwithhotwater. Thisprocedureprovedeffective, smoothly recovering the beam lifetime. Duringtheshutdown,aprototypefastinjectionkicker[ 21] wasalso installed. It wasonce installedinESRF-EBS stor- age ring and...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
2
e37e75dd-5561-4641-8cec-9b85a3945c16
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUO2M06 1134 MC2.A04: Photon sources: Circular AcceleratorsTUO2M06 : MC2 : Photon Sources and Electron Accelerators Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attri...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
2
30a311ae-5ac4-4ee3-9b43-2a68ce391b60
Figure2: (Left)Superconductingsuperbendonatestbench. (Right)Dipolefieldprofileofsuperconductingsuperbend, measured vs. simulated field. A peak field of 5.4 T is achievedwith a field profile matchingthe simulation. Figure 3: (Left) Set up of infrared (IR) camera calibration with a heater and temperature sensors. The pyr...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
3
8019613f-3dc2-4d40-b5db-cf5e3e21fb35
issues and schedule updates. The newly constructed ring is the firstlight-source storagering to employa substantial numberofpermanentmagnets torealize acompact multi- bendachromatlattice: thebeamorbitandlinearopticsalong the achromat arc are realized entirelywith permanent mag- nets. Thecommissioningresultsdemonstratet...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
3
4e0b0c10-5332-4782-910e-579a97bef388
doi:1/zero.alt4.11/zero.alt43/PhysRevAccelBeams.26./zero.alt4916/zero.alt41 [3]M. Böge, “SLS2.0 Storage Ring Commissioning”, in Proc. IPAC’25 , Taipei, Taiwan, Jun. 2025, pp. 1714–1717. doi:1/zero.alt4.18429/JACoW-IPAC2/zero.alt425-WECN117th International Particle Accelerator Conference, Deauville, France JACoW Publish...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
3
c7c2f53c-4619-4709-952f-3b048e6a1943
[4]S. Bettoni et al., “Insertion Devices Characterization at the SLS 2.0”, presented at IPAC’26, Deauville, France, May 2026, paper THP2051, this conference. [5]N. Kirchgeorg et al., “Swiss Light Source 2.0 vacuum sys- tem conditioning and first year of operation”, presented at IPAC’26, Deauville, France, May 2026, pap...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
4
85f985bf-df7d-4c95-b6d0-2b67ac8c6501
ch/event/12911/contributions/38354 [8]E. Weihreter, “Status of the European HOM damped nor- mal conducting cavity”, in Proc. EPAC’08 , Genoa, Italy, Jun. 2008, paper THXM03, pp. 2932–2936. [9]M. Böge et al., “Vertical alignment of the SLS 2.0 storage ring”, presented at IPAC’26, Deauville, France, May2026, paper THP201...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
4
165d2d52-3bbf-4624-bb4a-e0027ace7470
boostersynchrotronbycouplingresonancecrossing”, Phys. Rev. Accel. Beams , vol. 23, pp. 020701, 2020. doi:1/zero.alt4.11/zero.alt43/PhysRevAcce-Beams.23./zero.alt42/zero.alt47/zero.alt41 [14]C. Ozkan Loch et al., “Diagnostic contribution to the com- missioning of SLS 2.0”, in Proc. IBIC’25 , Liverpool, UK, Sep. 2025, pp...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
4
88b8e65d-7789-458c-b298-9c9525e8e48e
ments at SLS”, in Proc. IPAC’23 , Venice, Italy, May 2023, pp. 4814–4816. doi:1/zero.alt4.18429/JACoW-IPAC2/zero.alt423-THPL148 [18]F. Armborst et al., “Initial user operation of SLS 2.0”, pre- sented at IPAC’26), Deauville, France, May 2026, paper THP2014, this conference. [19]A.Lüdeke etal.,“Commonoperationmetricsfor...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
4
e9611026-4859-4bee-9a66-6e79c94f16b2
[21]M.Paraliev etal., “Developmentof fastand super-fastkicker systemforSLS2.0injection”,in Proc.IPAC’21 ,Campinas, SP, Brazil, May 2021, pp. 2889–2892. doi:1/zero.alt4.18429/JACoW-IPAC2/zero.alt421-WEPAB12217th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISS...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO2M06.pdf
4
b20e3c32-e5ba-40ff-be41-9d5c660d9da4
ANALYSIS OF LCLS-SC COMMISSIONING AND OPERATIONAL QUENCHES∗ N. R. Neveu†, S. Aderhold, L. E. Alsberg, L. Alston, D. Gonnella, J. T. Maniscalco, H. A. Marts, J. Nelson, R. D. Porter, L. Zacarias SLAC National Accelerator Laboratory, Menlo Park, CA, United States Abstract LCLS-SC achieved first light in 2023 and continue...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
0
394dc08d-fed9-4c05-bfa9-527b407903ca
quench rates in all cavities in the linac are identified and compared to operational quench rates and gradient limits. INTRODUCTION The Linac Coherent Light Source facility consists of two linear electron linacs, one normal conducting (NC) and one superconducting(SC)bothinstalledinthe existingSLAC 3 km tunnel. The NC l...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
0
e2fd600b-bb77-4d21-8609-68aa99eb98a8
increaseinbeamenergyfromtheLCLS-II-HEproject. Start- inginDecember2025,LCLS-SCwasshutdownforplanned constructionofLCLS-II-HE,anotherupgradeprojectthat willaddanadditional23cryomodulestotheLCLS-SClinac (L4). This will increase the operational energy from 4 GeV to8GeVstartingin2027. Afterthenewcryomodulesare commiossiton...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
0
b4fa3882-b7c5-482b-ab01-10df0943f855
milab. In this work, we review all commissioning and oper- ational quenches during the 2022-2025 run of LCLS-SC. In ∗WorksupportedbytheU.S.DepartmentofEnergyundercontractDE- AC02-76SF00515. †nneveu@slac.stanford.eduSection,wereviewthecurrentquenchclassificationmethod at SLAC and typical SRF cavity decay and quench wave...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
0
6a3df831-7d49-4a3d-b2dc-95f2974fc460
conducting, heat is dissipated throughout the cavity and it is no longer able to hold the operating gradient. These quenches are not as violent as SC magnet quenches, and oncethecavitycoolsdownagain,itcanresumeoperation. Typically,ifcaughtfastenough,turningoffthecavitypre- vents serious impact to the accelerator, and t...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
0
7f376a6f-0887-4c91-a814-b6d6b934268d
there is also the potential for trapped magnetic flux in the cavity after a quench. This is a persistent negative effect ofquenches,whichreducesthequalityfactorofthecavity (𝑄) [2]. Trapped magnetic flux can be purged with a fast cooldownofthecavity,butthatisnotaroutineoperation. Allattemptsaremadetoreducethenumberofwa...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
0
dbbef0bb-4439-474d-97e0-9d0eae8365d8
for a variety of reasons, including tunnel access, equipment health, or beam tuning in targetedareas. When the interlock sees this drop in power, it is loggedas a quench. To reduce the number of quench waveforms flagged for human review, aclassificationfunctionandwatcherprocesswerewritten to reset LCLS-SC cavities when...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
0
ea48f451-3442-4fc2-9f19-09d524f667a1
Figure 1: LCLS-SC facility layout. L4 is currently being installed under the LCLS-II-HE project, with commissioning expected in 2027. Figure2: Realquenchandnormaldecaywaveforms. Data taken from cryomodule 31, cavity 8 in L3. done by looking at the decay waveform saved after the inter- lockistriggered. Anexampleofaquenc...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
1
8c2e0eb1-9b04-437a-b9bc-39f32579aff5
decay, and (3) comparing the stored Q-value for that cavity (𝑄𝑠)tothenewlycalculated 𝑄𝐿. In(3)athresholdisusedto determine if the newly calculated 𝑄𝐿is labeled real or false. For step (2), an exponential form can be assumed for the amplitude of a normal cavity decay [ 2]: 𝐴(𝑡) = 𝐴 0⋅𝑒−𝜋𝑓𝑡 𝑄𝐿 (1) where𝐴0...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
1
faf5f1ab-4277-4c23-b8bb-f0a189807dc4
the decay was linearized. Wecan nowsolvefor 𝑄𝐿: 𝑄𝐿=𝜋𝑓 𝑥𝑒(3) Then, tocalculatethethreshold, whichistheminimum acceptable 𝑄𝐿before a quench is considered real, the saved 𝑄𝑠extracted from the quench file is multiplied by 0.6, for a threshold of 60%. Cavities that have interlock quench eventsflaggedasfalsearequ...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
1
7da40cf5-cb44-48f5-9240-df3bc0ef443e
threshold is sufficiently conservative. For further analysis false quench events were filtered out of the dataset and high count outliers (i.e. CM20/34/35) were investigated. The cryomoduleswithelevatedquenchlevelscomparedtothe machineaveragehad multipacting (MP) processing on one ormoreoccasions. MPprocessingisdonebef...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
1
f8dddf29-03cb-4f75-af67-0740cafdd12c
magnetic flux can be purged. In the case of the outliers CM34andCM35,bothhadRFpulsedprocessingapplied. InsteadofoperatingCW,shortRFpulsesareappliedinrapid successionwiththegoalofdisruptingtheconditionsatfield emitting sites in the cavity. This has been shown to increase theusablegradientduetofieldemissionincavitiesatse...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
1
1c41c38f-1078-4ced-a9c9-4b57ca746dbc
Figure 3: Percentageof real and falsequenchesoverthe 2022-2025 period. Figure4: Distribution ofquencheventsineachcavity. Only real quenches are shown here, false events and multipacting processing days are filtered out.Next,todistinguishbetweenintentionalandunintentional quenchevents,allprocessingeventswerefilteredout....
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
2
90c0b374-3219-44ae-af5d-88eb42f0b2a9
rate per cavity per day is below one. Some cavities have notquenchedorhaveonlyquenchedveryrarely(whiskers nearzero). ThisconclusivelyindicatestheLCLS-SClinac is operating stably with very low quench rates. CONCLUSION LCLS-SChasbeenoperatingsuccessfullyfrom2022to 2025. The current quench interlock and classification met...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
2
ac05e898-0a32-4fcd-8b45-dfc630032d30
ongoing works in the community [ 5–9] ACKNOWLEDGMENTS ThisworkusedtheresourcesoftheSLACSharedScience Data Facility (S3DF) at SLAC National Accelerator Lab- oratory. S3DF is a shared High-Performance Computing facility,operatedbySLAC,thatsupportsthescientificand data-intensivecomputingneedsofallexperimentalfacilities an...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
2
d1e36719-fea0-40d5-bd23-7673caa3c622
DepartmentofEnergy’sOfficeofScience. Thisworkwas funded under DOE Contract No. DE-AC02-76SF00515. REFERENCES [1]B. Auneet al., “Superconducting tesla cavities”, Physical Re- view Special Topics - Accelerators and Beams , vol. 3, no. 9, 2000. doi:1/zero.alt4.11/zero.alt43/physrevstab.3./zero.alt492/zero.alt4/zero.alt41 ...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
3
eacbead9-8b78-4818-a602-534c5bb7c3e5
celerators”, Frontiers in Physics , vol. 13, May 2025. doi:1/zero.alt4.3389/fphy.2/zero.alt425.1553993[6]A.Bellandi etal.,“Onlinedetuningcomputationandquench detection for superconducting resonators”, IEEE Transactions on NuclearScience , vol. 68, no. 4, pp. 385–393, Apr. 2021. doi:1/zero.alt4.11/zero.alt49/tns.2/zero....
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
3
1b449b96-9f23-4725-a0e4-c42337fbdefc
[9]M.M.Rahman,A.Carpenter,K.Iftekharuddin,andC.Ten- nant,“Acceleratingcavityfaultpredictionusingdeeplearning at jefferson laboratory”, Machine Learning: Science and Tech- nology, vol. 5, no. 3, p. 035078, 2024. doi:1/zero.alt4.1/zero.alt488/2632-2153/ad7ad617th International Particle Accelerator Conference, Deauville, ...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO7T03.pdf
3
1a7dc8b0-2575-43df-b538-65f0bca83ee8
FIRST MIXED HE/C ION BEAMS IN A CLINICAL FACILITY: TWO YEARS FROM CONCEPT TO FIRST ION IMAGING EXPERIMENTS E. Renner∗, K. Holzfeind, F. Ulrich-Pur, TU Wien, Vienna, Austria N. Gambino, L. Grevillot, M. Kausel, L. Kelleter, D. Prokopovich, C. Schmitzer, MedAustron, Wiener Neustadt, Austria H. Fuchs, Medical University o...
D:\Daily_ihep\Conferences\IPAC2026\TUO\TUO8T01.pdf
0