id
stringlengths
36
36
text
stringlengths
1
1k
source
stringlengths
42
191
page
int64
0
1.03k
e5931e92-20df-41d6-b33b-03d6656fcd61
Figure 3: The patterns of RF voltage amplitude (left), synchronous phase (center), momentum filling factor (right) obtained from the tracking simulation for various acceleration times in the case of ℎ = 5for acceleration. Figure 4: The patterns of RF voltage amplitude (left), synchronous phase (center), momentum fillin...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4644.pdf
2
5d50ccaf-b2d2-4d43-983d-c9eab310c45b
repeated until the maximum MFF reaches close to 0.8. Figures3and4showthepatternsofRFvoltageamplitude, synchronousphase,andmomentumfillingfactorobtained fromthetrackingsimulationforvariousaccelerationtimesin thecaseof ℎ = 5andℎ = 11,respectively,foracceleration. Forℎ = 5, acceleration with maximum RF voltage below 100 k...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4644.pdf
2
de4f9ff8-9e9a-4873-bc0d-62659a23f02c
high-power RF system, but additional cost is required to produceandinstallthem. BecausetheavailablespaceintheMR for installing cavities is limited, the types and numbers of cavities need to be studied. Forℎ = 11with existing RF cavities, the existing RF systemcanbeused,minimizingadditionalcost. Ontheother hand,becauset...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4644.pdf
2
9c7c151d-719c-4707-81b9-2bbe58394fa7
ions in the J-PARC MR are estimated from calculations andlongitudinalbeamdynamicssimulationswithvarious harmonicnumbersandaccelerationtimes. Withtheaccel- erationtimelargerthan3s,theaccelerationofAu79+ions can be achieved with the maximum RF voltage less than 100kV.Furtherworkwillfocusonestimatingtherequired specificat...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4644.pdf
2
a4437240-7197-48a3-9b7e-10328b5d928e
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP4644 2264 MC4.A17: Hadron accelerators: High Intensity AcceleratorsWEP4644 WEP: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the auth...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4644.pdf
2
dc762049-2c47-42fc-b7a8-3ff23bc6838b
REFERENCES [1]T. Koseki et al., “Beam commissioning and operation of the J-PARC main ring synchrotron”, Prog. Theor. Exp. Phys. , vol. 2012, no. 1, p. 2B004, 2012. doi:1/zero.alt4.1/zero.alt493/ptep/pts/zero.alt471 [2]S. Nagamiya, “Introduction to J-PARC”, Prog. Theor. Exp. Phys., vol. 2012, no. 1, p. 2B001, 2012. doi:...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4644.pdf
3
1d02c9c8-cca5-4514-88ac-1195d3ca13e4
[5]K. Aokiet al., “Proposal for dielectron measurements in heavy-ion collisions at J-PARC with E16 upgrades”. https://j-parc.jp/researcher/Hadron/en/pac_21/zero.alt47/ pdf/P87_2/zero.alt421-13.pdf [6]H. Harada, P. K. Saha, and M. Kinsho, “Simulation Study of Heavy Ion Acceleration in J-PARC”, Mar. 2021. doi:1/zero.alt4...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4644.pdf
3
5dde3c8e-c827-4f39-a762-ce66ecdf040b
Switzerland, Rep. CERN-2011-004, 2011. doi:1/zero.alt4.517/zero.alt4/CERN-2/zero.alt411-/zero.alt4/zero.alt44 [10]J. Coupard et al., “LHC Injectors Upgrade, Technical De- sign Report vol. II: Ions”, CERN, Geneva, Switzerland, Rep. CERN-ACC-2016-0041, Apr. 2016. doi:1/zero.alt4.17181/CERN.L6VM.UOMS17th International Par...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4644.pdf
3
d1bd66e3-1c41-44e7-8ed5-b5c6ba9f12b6
CONCEPTUALDESIGNOF A 2.45 GHzECR ION SOURCEFORPROTON THERAPY R.C.Qin1,2, X.X.Huang∗3, C.Yu3, P.Wang3, Y.X.Lu3, Y.S.Guo3, Y.F.Lan1,2, D.H.Su1,2, W.C.Fang†3, Z.T.Zhao3 1Shanghai Institute of Applied Physics,Shanghai, China 2University of Chinese Academy of Sciences, Beijing, China 3Shanghai Advanced Research Institute, S...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4646.pdf
0
08912581-7e5d-4670-a816-956a07828754
INTRODUCTION Iontherapyhasreceivedgrowingattentioninrecentyears as an advanced radiotherapy modality. Owing to the Bragg- peak behavior, ion therapy enables highly conformal tumor irradiationwhilereducingthedosetosurroundinghealthy tissues[1]. Protonsandcarbonionsarethetwomostcom- monly used particles in ion therapy, w...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4646.pdf
0
bb2fab81-7d1d-4e6e-9de8-643bdd2b9b0f
facilities,inwhichareliablehigh-currentprotonsourceis an essential front-end component. Electron cyclotron resonance ion source (ECRIS) is a typeofcathode-freeplasmasourceinwhichelectronsare resonantly heated by microwaves under a suitable magnetic fieldconfiguration. Theheatedelectronssubsequentlyionize the working ga...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4646.pdf
0
d819fb33-6d02-4f25-9b70-696c22bd3901
wellsuitedforthefrontendsofmedicalprotonaccelerator systems. ∗huangxx@sari.ac.cn †fangwc@sari.ac.cnAt Shanghai Synchrotron Radiation Facility (SSRF), a full-linac proton therapy facility has been proposed as a compact and cost-effective solution for future FLASH treat- ment[5]. Asakeycomponentoftheinjector,theRFQhas be...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4646.pdf
0
f1b11922-693d-45dd-8811-6fa92bfb3c09
tem. Based on this configuration, the following sections describe the detailed design of the magnetic confinement system,themicrowavesystemandthe beam extractionsys- tem. Figure 1: Layoutof the 2.45 GHz ECR proton source. Magnetic Confinement System In this prototype, electromagnets were adopted instead ofpermanentmagn...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4646.pdf
0
ed6aadb6-aca9-4e49-a077-ce0aea8255e2
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP4646 2266 MC4.T01: Hadron accelerators: Proton and Ion SourcesWEP4646 WEP: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s)...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4646.pdf
0
ac9ed263-bea9-45b4-9b37-7322b88731fd
tion. The model used in Opera is shown in Fig. 2. The three-solenoidconfigurationoffersmoreflexibilityinmag- netic field tuning. Different field configurations could be tested just by tuning the current of the central solenoid. The simulation is performed using Opera [ 7]. As an example (Fig.3),threeECRresonancepointsa...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4646.pdf
1
a6892bb7-b18e-4718-83c7-c2fd09b3df3a
hancement, which facilitates plasma ignition and stable dis- charge. The ridged waveguide is designed and optimized with CST [ 8] and the model used in CST is shown in Fig. 4. Calculatedresultof S11isshownFig.5. Theresultindicates that the microwave can be transmitted with low reflection over a wide frequency range cen...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4646.pdf
1
e270ed4b-6aaf-4b51-9aaa-8b0211de77bd
frombeingacceleratedintotheplasmachamber. APierce- typeelectrodegeometrywithanangleof 67.5∘isadoptedto providepreliminaryelectrostaticfocusing. Theextraction systemisdesignedusingIBSimu[ 9],andsimulatedbeam extractionresult isshowninFig.6. Theradiusof thethree electrodesare3mm,4mm, 4mm,respectively. Byoptimiz- ingthepo...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4646.pdf
1
2ef23d5a-eea3-4084-a907-bc8ed4d017bf
tive position of the electrodes will be adjusted to control the convergence or divergence of the beam. CONCLUSION The conceptual design of a 2.45 GHz ECR proton source prototype has been presented in this paper. Main subsys- temsincludingthemagneticconfinementsystem,microwave systemandbeamextractionsystemweredesignedan...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4646.pdf
2
40ddaa61-9279-4918-a3bd-f5c182896ca5
tion of China(No.12505171 and No.12405178). REFERENCES [1]M. Durante, R. Orecchia, and J. S. Loeffler, “Charged-particle therapyincancer:clinicalusesandfutureperspectives”, Nat. Rev. Clin. Oncol. , vol. 14, no. 8, pp. 483–495, 2017. doi:1/zero.alt4.1/zero.alt438/nrclinonc.2/zero.alt417.3/zero.alt4[2]A. Mairani et al., ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4646.pdf
2
55b2f097-9265-43b0-829f-301dd983bd23
2010. doi:1/zero.alt4.1/zero.alt463/1.3266145 [5]W.-C.Fangetal.,“Protonlinac-basedtherapyfacilityforultra- highdose-rate(FLASH)treatment”, Nucl.Sci.Tech. ,vol.32, no. 4, p. 34, 2021. doi:1/zero.alt4.1/zero.alt4/zero.alt47/s41365-/zero.alt421-/zero.alt4/zero.alt4872-4 [6]Y.-X. Lu, W. -C. Fang, Y. -S. Guo, and Z. -T. Zha...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4646.pdf
2
2a105105-b75e-4441-b235-9ad5abfb9264
[9]T. Kalvas, O. Tarvainen, T. Ropponen, O. Steczkiewicz, J. Ärje, and H. Clark, “IBSimu: A three-dimensional simulation softwareforchargedparticleoptics”, Rev.Sci.Instrum. ,vol.81, no. 2, 02B703, 2010. doi:1/zero.alt4.1/zero.alt463/1.32586/zero.alt4817th International Particle Accelerator Conference, Deauville, France...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4646.pdf
2
9caba54f-4c25-4c20-be44-bb541a63585f
DEVELOPMENT OF A GAS -TARGET LASER ION SOURCE TEST SYSTEM FOR THE LAPRIS CONCEPT S. Matsui†, T. Yorita, Y. Matsuda, H. Kanda, M. Fukuda, T. Tsujisaka, Y. Iwashita The University of Osaka, Osaka, Japan T. Nakamura , High Energy Accelerator Research Organization R. Hajima, K. Kawase, National Institute...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
0
a0a01232-6729-4ee1-8f64-dc3380a7ecb3
erated by strong -field ionization in a gas target. Time -of- flight measurements using an MCP detector showed laser - correlated ion signals and their dependence on the extra c- tion voltage. These results provide a preliminary demon- stration of laser -induced ion extraction relevant to future LaPRIS development. ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
0
1c956162-5aa4-46ca-bf02-5c8d45e6ea07
beam resolution. While the transverse emittance can be improved by beam slits, improvement of the longitudinal beam quality requires the phase slit of the cyclotron. To obtain high energy resolution, the injected beam must be confined within a narrow RF phase width. However, since the ECR ion source produces a ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
0
381f52f6-0c1f-489c-81f8-7f1530cdb268
is a pulsed ion source that generates localized plasma in a gas jet using a focused ultrashort -pulse laser and extracts ions by an RF electric field. Since the laser pulse duration is on the sub- picosecond scale, the generated ion bunch is expected to have an intrinsically ultrashort bunch duration . Therefore...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
0
ab4c585e-901e-43af-8b92-d319afa7a6e5
W/cm² used in this experiment, the ionization yields are estimated to be about 50 ions/shot for N₂ and about 10 ions/shot for H₂. As a step toward the development of LaPRIS for practical application in precision nuclear physics experiments, we constructed a laser -induced ion extraction test system using DC hi gh...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
0
09a3c987-8ea4-4d4a-8fdd-d1eec9f39d55
pressure was 5×10⁻⁴ Pa without gas injection and 1×10⁻² Pa during pulsed gas injection with an average flow rate of 1 sccm. For gas injection, we used the same piezoelectric pulsed gas valve as in the previous LaPRIS study [1]. The valve was operated with a pulse width of 1 ms and a repetition rate of 10 Hz. For ti...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
0
b571864b-6211-4124-9b9a-16eb7dfe3377
timing signal. This signal was frequency- divided by a DG645 delay generator and sent to the piezoelectric valve control system through an optical fiber. Air was used as the target gas in this experiment. A Yb fiber femtosecond laser with a pulse duration of 340 fs, a repetition rate of 50 kHz, and a pulse energy...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
1
f4dcfcd0-af0e-4688-87dd-cf7edfd3e076
a DC high vol tage of 3 –5 kV and detected by an MCP lo- cated about 6 cm downstream of the extraction electrodes. For signal acquisition, the time of flight (TOF) from the laser focal region to the MCP detector was measured. The TOF time origin was defined as the rising edge of the pho- todiode signal detecting lea...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
1
b6ebe19d-9512-46e8-b083-7a77f5772704
position directly affects the ion generation efficiency, alignment was performed using a dedicated jig. Fig. 3 shows an observation image during the alignment proce- dure and the measured laser focal spot profile. First, the optical axes of the focusing lens and the achro- matic imaging lens were aligned. Then, a j...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
1
a4197d63-5f1c-4db3-ae2f-5bc1c68881bc
matic imaging lens with f = 80 mm, and the lens position was adjusted to obtain the sharpest image on the CCD cam- era. Using the known drill tip diameter of 40 µm as a ref- erence, the magnification of the imaging optics was esti- mated to be about 11. Under this condition, the depth of field was about 30 µm, as shown...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
1
394554da-410a-4c1e-9838-4d40611f9e1f
Figure 4 shows the TOF distributions of the MCP signals measured at extraction electro de voltages of 3 kV , 4 kV , and 5 kV . The TOF histograms were constructed with a bin width of 20 ns. For each voltage condition, 100 MCP -trig- gered waveforms were accumulated. The numbers of peak candidates were 48, 47, and 5...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
1
43eb2e83-11a1-4ebc-967f-177dcc365ba3
accelerated by the extraction field. The pre -trigger region, where laser -induced ions cannot physically arrive, was used to estimate the background level. The total number of MCP peak candidates observed after the laser timing was significantly higher than that expected from the pre -trigger background, indicat...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
1
5c0b36b9-b03d-4440-ac24-0161e21be462
DISCUSSION As shown in the Introduction and Fig. 1, the MO -ADK- based estimates gave ionization yields of about 50 ions/shot for N₂ and about 10 ions/shot for H₂ under the present experimental conditions at a peak intensity of 1×10¹⁴ W/cm². These values represent the estimated num- ber of ions generated near the...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
2
7647a945-9eb8-4b5c-8576-72c903bc8d5c
As an order -of-magnitude estimate, the pressure- scaled stopping power of protons from the PSTAR database gives an estimated distance of about 3 m for a 1% energy loss of 1 keV protons at a chamber pressure of 1×10⁻² Pa [5]. This distance is much longer tha n the flight length in this exper- iment, about 6 cm, indi...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
2
0ba31626-bf85-428c-a4f0-fd4fca506d9a
alization of LaPRIS, we constructed a laser -induced ion ex- traction test system using a DC extraction field and per- formed an initial operation test based on TOF measure- ments. MO -ADK- based estimates gav e ionization yields of about 50 ions/shot for N₂ and about 10 ions/shot for H₂ un- der the present experiment...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
2
26e24d0d-dc93-4507-bac1-f2a870219b70
MCP peak candidates were distributed over several hun- dred nanoseconds. In future work, a laser with a higher peak intensity and a purified gas target with higher density will be introduced to advance the demonstration of LaPRIS using gases such as H₂. ACKNOWLEDGEMENT S This work was supported by JST SPRING, Gran...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
2
6eb3f498-81fa-4492-9a72-aa415fa9553b
[2] X. M. Tong, Z. X. Zhao, and C. D. Lin, “Theory of molecular tunneling ionization,” Phys. Rev. A, vol. 66, p. 033402, Sept. 2002.doi:10.1103/PhysRevA.66.033402 [3] S.-F. Zhao, C. Jin, A.-T. Le, T. F. Jiang, and C. D. Lin, “De- termination of structure parameters in strong -field tunneling ionization theory of...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
2
253d01fd-161e-4750-b706-1da0ecfb79ec
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP4647 MC4.T01: Hadron accelerators: Proton and Ion Sources 2271WEP: Poster session WEP4647 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s)...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4647.pdf
2
5207ce45-8ef6-44b1-9218-c0d2fead8a49
EMPIRICAL ORBIT CORRECTION FOR 3-GeV PROTON BEAM TRANSPORT IN FRINGE FIELD FROM FRONT SOLENOID OF SECONDARY BEAMLINE Y. Yamaguchi∗, S. Meigo, Japan Atomic Energy Agency, Tokai, Japan T. Yamazaki, High Energy Accelerator Research Organization, Tsukuba, Japan Abstract A3-GeVprotonbeamfromarapidcyclingsynchrotron (RCS)isp...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
0
59f450ae-e916-4d8e-b829-04902970d3d9
on the neutron production target, the beam position was measuredasfunctionofexcitationcurrentsforthecoilsofthe solenoid. Inthispaper,wereportresultsofthemeasurement analysis and the orbit correction based on the empirical analysis. INTRODUCTION The 3-GeV proton beam transport from a rapid cycling synchrotron(RCS)toaneu...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
0
bdee38c5-1bad-4db9-934d-bb4638f781c6
HS1 Y22 Y23 Figure 1: Plan view of 3NBT line between targets. The pro- tonbeamcomesfromtheleftsideofthefigureandpenetrates themuonproductiontarget. Thefourbeamlinessurround- ingthetargetextendtoexperimentalareas. Atthefrontof theH-line, alarge-aperturecapturesolenoid HS1isplaced. Between the targets, two vertical steer...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
0
2d5100cc-a1cc-4b3e-9d12-156878e48b3e
with a wide range of momenta. The first beam to the H-line was extracted in 2022 [ 5]. After the H-line operation was started, a proton beam position change in vertical direction was observed at the most downstream profile monitor placed 2mupstream of theneutrontarget. Thebeampositionchangefromthecenter position result...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
0
a528d2e4-4c31-41f5-b04b-1902420e1a11
steering magnets Y22 and Y23 shownin Fig. 1. Excitation currents of the Y22 and Y23 are tuned based on orbit calcu- lation using stragetic accelerator design (SAD) code shown inFig.2andexcitationcurrentsoftheHS1-1,HS1-2,and HS1-3. In the previous correction method, Y22 and Y23 currentsweredeterminedontheassumptionthata...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
0
7a685764-7578-4c29-93e7-56fa54effe42
combination. Thepurposeofthepresentstudyistoreveal therelationbetweenthebeampositionchangeandthecoil currents. We present the relation and results of empirical orbit correction based on the relation. INVESTIGATION OF RELATION BETWEEN BEAM POSITION AND COIL CURRENTS The measurement of the proton beam position was per- f...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
0
1fe889cf-d6e7-4081-9a9f-07eaef96ab5c
0.273 ,0.098 ,0.058 mradTotal HS1-1 HS1-2HS1-3 0.429 Measuring positionY23 Y22 Quadrupole magnetsMuon production target[m]y[mm]~~Figure 2: Proton beam orbit calculation for orbit correction by vertical steering magnets Y22 and Y23 using strategic accelerator design (SAD) code. The horizontal and vertical axesarelongi...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
1
8ad74ec1-6d93-42b7-beeb-42bd88ec2ed8
wire profile monitor (MWPM) approximately 2mupstream of the neutron production target. The MWPM has fourteen siliconcarbidewireswith7-mmpitchforconstantlymoni- toring vertical beam position and width. The vertical beam position was extracted by Gaussian fitting. Figure3showstheprotonbeampositionchangeinvertical directi...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
1
f734cac2-8152-48f2-be79-a7ccf74a7bc9
Δ𝑦 = −0.410𝐼1−2, (2) where𝐼1−2istheHS1-2excitationcurrent. FortheHS1-3, thelinearexpressionwasobtainedusingtheHS1-3excitation current𝐼1−3as Δ𝑦 = −0.242𝐼1−3. (3) The non-linear expression of Eq. (1)indicates that the as- sumption of proportionality between the deflection angle duetothefringefieldandexcitationcurre...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
1
d4a4be79-5253-4e1c-a2fc-20ce11164ffb
the figure, observed Δ𝑦is shown as function of 𝐼1−2at 𝐼1−1= 0.625and1.25kAtogether with that calculated by linearlysumming Δ𝑦forsingle-coiloperationinFig. 3. The calculated Δ𝑦underestimates the observed one. The dis- crepancybetweenthecalculatedandobserved Δ𝑦tendsto become large at high current for both the HS1-1...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
1
39c802f9-f48f-4b33-8bef-a1f66f8d3984
behaviorduetotheHS1-1. Theorbitcorrectionsystemcon- trolstheexcitationcurrentofY22andY23bymonitoring thecurrentsofHS1-1,HS1-2,andHS1-3. Figure 5shows trends of the vertical beam position in increasing the coil currents. The trend with linear correction shown by dashed step line displays a hump-shaped curve in increasin...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
1
81376ba2-feac-4385-a0b4-75180b6eb1b0
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP4648 MC4.T12: Hadron accelerators: Beam Injection/Extraction and Transport 2273WEP: Poster session WEP4648 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
1
45a43148-7ae2-4050-a505-a7da92aceae2
-3.5-3-2.5-2-1.5-1-0.5 0 0 0.5 1 1.5 2 2.5I1-1 = 0.625 kA I1-1 = 1.25 kA∆y [mm] Excitation current of HS1-2 [kA]Observed Linear sumFigure 4: Proton beam position change in vertical direction asfunctionofHS1-2excitationcurrentinHS1-1andHS1-2 operation. The excitation currents of the HS1-1 are 0.625 and1.25kA. Blue...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
2
f6b6b8f0-2f60-4573-b594-f19e07583591
andHS1-3areshownwithblue,cyan,andpurplelines,re- spectively. as functions of 𝐼1−2and𝐼1−3 Δ𝑦 = 𝑎2(𝐼1−2,𝐼1−3)𝐼2 1−1+𝑎1(𝐼1−2,𝐼1−3)𝐼1−1.(4) The coefficients 𝑎1(𝐼1−2,𝐼1−3)and𝑎2(𝐼1−2,𝐼1−3)were ex- pressed with quadratic functions based on fitting results for Eq. (1) as 𝑎1(𝐼1−2,𝐼1−3) = −0.071𝐼2 1−2−0.134�...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
2
55e85853-e0ea-42d8-9e21-cb3ea26d6f9c
out the correction are shown as function of 𝐼1−1at𝐼1−2= 2.5kAand𝐼1−3=1kA. The corrected Δ𝑦shows an ap- proximatelyconstanttrend, whilethe Δ𝑦withoutcorrection reaches−5.5mm overtheallowablelimit. Thecorrected Δ𝑦 trenddemonstratesthatthe protonorbit changeis wellcor- rected in multiple-coil operation as well as in ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
2
f140013d-c2be-4b90-a007-d89ab2fbecee
erations should provide valuable information for improving the orbit correction method. -6-5-4-3-2-1 0 0 0.5 1 1.5 2With correction Without correctionI1-2 = 2.5 kA I1-3 = 1 kA∆y [mm] Excitation current of HS1-1 [kA] Figure 6: Proton beam position change in vertical direction asfunctionofHS1-1excitationcurrentinthr...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
2
9a24d240-6516-48ed-88e1-baefdd6a4ef7
introducedtothebeamorbitcorrection. Theempiricalorbit correctionmethodwiththeexpressionswasdemonstratedto workovertheentireHS1operationrangeinthepresentbeam optics of the 3-GeV proton beam transport line. In future studies, validity of the present method in different beam optics and the non-linear mechanism will be inv...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
2
28044d1f-c2ad-4380-b34d-5136ca2e920f
REFERENCES [1]S.Sakamoto etal., “Advanceddesign of high-intensity beam transport line in J-PARC”, Nucl. Instrum. Methods Phys. Res. A, vol.562, no. 2, pp. 638–641, Jun. 2006. doi:1/zero.alt4.1/zero.alt416/j.nima.2/zero.alt4/zero.alt46./zero.alt42./zero.alt476 [2]S.Meigo,M.Ooi,andH.Fujimori,“Two-parametermodelfor optimi...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
3
e8dfed01-0149-450e-ad8a-681bbdbf496a
[4]N. Kawamura et al., “New concept for a large-acceptance general-purpose muon beamline”, Prog. Theor. Exp. Phys. , vol. 2018, no. 11, p. 113G01, Nov. 2018. doi:1/zero.alt4.1/zero.alt493/ptep/pty116 [5]T. Yamazaki et al., “New beamlines and future prospects of theJ-PARCmuonfacility”, EPJWebConf. ,vol.282,p.01016, Apr....
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4648.pdf
3
94134a08-523c-42d4-9ac0-c2cbd9e6db28
SIMULATION-BASED OPTIMIZATION OF A BENT SILICON CRYSTAL FOR BEAM LOSS REDUCTION IN THE J-PARC MAIN RING SLOW EXTRACTION R. Muto∗, T. Asami, T. Kimura, A. Matsumura, S. Murasugi, K. Numai, K. Okamura, Y. Shirakabe, M. Tomizawa, E. Yanaoka High Energy Accelerator Research Organization, Tsukuba, Japan K. Itahashi, Y. Sait...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
0
26a14e88-0117-484d-874a-648af4407622
angularacceptanceaccommodatesthesubstantialvertical beamsizeandrelaxestightcrystaltorsionconstraints. Fur- thermore,weevaluatedtheimpactofanticlasticdeformation ondeflectionefficiencyforboththe (110)and(111)crystal- lographicplanes. Althoughthe (111)planeismoresuscepti- bletoperformancedegradationfromanticlasticdeforma...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
0
216fe061-515b-43bc-b74c-e28b88a6fc07
Experimental Facility [ 2]. Protons accelerated to 30GeV are extracted over a period of ∼2seconds . The most critical beamqualitiesrequiredforthisslowextractionbeamarehigh beamintensityandtemporalflatnessduringtheextraction period. The performance of the slow extraction at the J-PARC MR has gradually improved since the...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
0
628b0d0c-56eb-4874-bc6c-643aabf04901
theHadronExperimentalFacility,anewrotatingtargetfor acceptingover 150kWbeampowerisunderdevelopment, ∗ryotaro.muto@kek.jp Figure1: Trendplotsofthebeampowerandspilldutyfactor for the J-PARC MR slow extraction. andthereisastrongdemandfromphysicsexperimentsfora furtherincreaseinbeampower. Oneofthechallengesthat mustbeoverc...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
0
ec23c8ea-ef16-4d43-818c-b81ac4bb26b4
CERN SPS [ 3,4]. In this paper, the beam loss reduction effectofabentsiliconcrystalforthecaseof 30GeVprotons in the J-PARC MR was investigated through simulations using FLUKA [ 5]. BEAM DEFLECTION EFFECT OF THE BENT CRYSTAL Abentcrystaldeflectspositivelychargedparticlesprimar- ily through two mechanisms: channeling (CH...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
0
c6f8d5c3-f932-4819-a4db-ffc4773109d6
tothecrystal’sbendingdirection. Thedeflectionangletakes auniquevaluedetermined bythe crystalstructure andcan- not be varied; however, since the angular acceptance of VR is determined by the bending angle of the crystal, a larger acceptance can be obtained compared to channeling. Fig-17th International Particle Accelera...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
0
844d969f-f489-48c5-ba9b-cf435dfa0590
Figure 2: The deflection effect of the bent silicon crystal for 30GeVprotonsestimatedbyFLUKA.Horizontalaxisisthe beam incident angle, and the vertical axis is the deflected beam angle. The crystal’s bending angle and longitudinal length are 200µrad and 1mm, respectively. ure2showsthedeflectioneffectofthebentsiliconcrys...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
1
4316b40a-ce9d-439c-9296-3b2f82662e01
angle. Thecrystalhasalongitudinallengthof 1mmanda transverse thickness of 0.2mm, and the(110)plane is used for the beam deflection. Table 1: Normalized Beam Loss Estimatedusing FLUKA Configuration Normalized Beam Loss No Mitigation 100 Channeling 48 Volume Reflection 53 CRYSTAL BENDING METHOD Thecrystalisbentusingantic...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
1
31efd92d-854c-4aed-8336-40f076186112
which requiresdecreasing 𝑅. This consequentlyincreases 𝛿𝑥shownintheFig. 3,leadingtoadegradationinthebeam Figure3: Conceptualdrawingoftheanticlasticdeformation. lossreductioneffectforparticleslocatedawayfromtheideal orbit plane in the vertical direction. Toestimatethemagnitudeofthis 𝛿𝑥,wecarriedoutfinite element me...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
1
19945f5a-a09d-41cc-b2e7-e10b4f87564f
of the6 × 6compliance matrix, under the approximation thatdeformationissmall[ 8]. The𝑅𝐴/𝑅obtainedfromthe compliance matrix itself is also plotted in Fig. 4, showing good agreement with the ANSYS calculation results. From this result, when using the (110)plane,𝑅𝐴/𝑅is minimized at𝜃 = 0∘, which minimizes the 𝛿𝑥. ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
1
8d641f64-e38d-4a5e-9241-27ac779a60ca
loss reduction effect due to the 𝛿𝑥but also imposes stricter Figure 4: Calculated 𝜃dependence of 𝑅𝐴/𝑅.(110)plane is used for beam deflection. 𝜃is the angle between beam injecion axis and ⟨001⟩axis.17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN:...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
1
6d51e604-45f1-400e-ba1c-a54c2b341a08
Figure5: Anglemisalignmentdependenceofthenormalized beam loss estimated by FLUKA. The channeling effect is used with (110)plane. requirements on the torsion of the bent crystal. Therefore, we estimated the impact of the angular misalignment for channelingusingFLUKA.TheresultsareshowninFig. 5. Itshouldbenotedthatevenwit...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
2
d6ce61a0-3bbe-4064-ad51-102f3f9ae026
constraint on the torsion of ∼2µrad/mm. On the other hand, when volume reflection is used and the crystal bending angle is set to 200µrad, an angular ac- ceptance of ∼±80µrad can be secured, resulting in a torsion requirementofaround ∼10µrad/mm . Becausethis isa fea- siblevalue,wedecidedtoadoptvolumereflectionandevalu-...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
2
e05f7f52-f2a5-4788-8b36-958b0552cc73
Figure 6: The estimations of 𝛿𝑥effect on normalized beam losses estimated using FLUKA. The estimations are for vol- ume reflection using the (110)and(111)planes, both with and without the beam diffuser downstream the crystal.Table2: NormalizedBeamLossEstimatedusingFLUKA Including Finite Vertical Beam Size Effect Conf...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
2
749d023e-29f6-4438-aaab-31eb59750bcf
plane,𝑅is1.3musing𝑅𝐴/𝑅 = 3.82 . The𝛿𝑥corresponding to a vertical beam size of 7mmare27µmfor(110)plane and 38µm for (111)plane. Assuming a vertical beam profile of a Gaussian with 𝜎 = 7mm, the beam loss reduction effects obtained by convoluting the beam profile and results of Fig. 6are sum- marizedinTable 2. When...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
2
a6068a7a-8973-46d9-8e70-05eff4f2aa19
silicon crystal for slow extraction at the J-PARC Main Ring. Wedecidedtoemployvolumereflectionduetoitshightoler- ance for the angular misalignment of the crystal. The beam loss reduction effect was estimated using FLUKA, taking into account the dependence of the crystal’s transverse posi- tiononitsverticalpositioncause...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
2
5c69f8be-e2d1-40cb-97c7-4d6ecb168496
ing the use of crystals in slow extraction, as well as for their supportinutilizingtheFLUKAcodeforcrystalsimulations. We are also grateful to V. Guidi and M. Romagnoni for valuable insights into crystal fabrication. This work was supportedbyJSPSKAKENHIGrantNumbersJP24K15604 and JP22H04941.17th International Particle Ac...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
2
506d1d26-08f2-43fd-8380-1e17d1fe37a4
REFERENCES [1]Y. Yamazaki et al., “Accelerator technicaldesign report for J- PARC”, KEK, Tsukuba, Japan, Rep. KEK-REPORT-2002-13, JAERI-TECH-2003-044, J-PARC-03-01, Mar. 2003. [2]M. Tomizawa et al., “Slow extraction from the J-PARC Main Ring using a dynamic bump”, Nucl. Instrum. Methods Phys. Res., Sect. A , vol. 902, ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
3
e0e7ef01-d14e-4739-9954-dac701abc7ee
Beams, vol. 22, p. 093502, Sep. 2019. doi:1/zero.alt4.11/zero.alt43/PhysRevAccelBeams.22./zero.alt4935/zero.alt42[5]C. Ahdida et al., “New capabilities of the FLUKA multi- purpose code”, Front. Phys. , vol. 9, 2022. doi:1/zero.alt4.3389/fphy.2/zero.alt421.788253 [6]R. Mutoet al., “Simulation studies on bent silicon cry...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
3
0bb39836-8bd5-444b-8599-4580c5510299
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP4649 MC4.T12: Hadron accelerators: Beam Injection/Extraction and Transport 2279WEP: Poster session WEP4649 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4649.pdf
3
66af1b77-26ac-4e2c-8396-bc830a6691f5
SYNCHRONIZATION OF LONGITUDINAL HOLLOW ELECTR ON BEAM AND ION BEAM IN A STORAGE RING* X. D. Yang†, Institute of Modern Physics, CAS, Lanzhou, China Abstract In the cooling storage ring, a low -temperature electron beam from the electron cooling device overlaps with a high- temperature ion beam in the storage ri...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
0
756a1e5b-a542-4079-9deb-bd6b144577c7
center. This article introduces a synchronization scheme for longitudinal hollow electron beams and ion beams. The scheme includes pulse measurement, triggering delay, syn-chronization monitoring, and future feedback for auto-matic correction. This ensures the pulses are always syn-chronized. The scheme will be used ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
0
2fa98bb2-0499-4aa5-abbb-25581990c001
same average velocity. Through Coulomb interactions, the hotter ion beam transfers excess energy to the cooler elec-tron beam, thereby reducing the transverse emittance and longitudinal momentum spread of the ion beam and achieving a higher phase space density. The electron cooling force is proportional to the elec...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
0
8e9795a5-12bd-45ee-a98d-b432ff02717d
by a radio -frequency accelerator, and it consists of a series of short pulses with a uniform distribution of electron beam intensity in the longitudinal direction [3-5]. The ion beam in the storage ring presents a Gaussian dis- tribution in the longitudinal direction. Under continuous electron cooling, the ion b...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
0
a778abac-b729-4ca3-9592-d2ae359522b4
The longitudinal hollow electron beam is expected to ob- tain benefits in the following aspects. • Suppress intra -beam scattering. • Control the longitudinal distribution of the ion beam. • Make the beam bunch contain as many particles as possible. • Increase the lifetime of ion beams in the storage ring. T...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
0
1e7c2361-c545-4bd0-b4d7-931b7f72e0d6
longitudinal direction. The electron beam is generated by an electron gun, which is a capacitive structure. The voltage applied to the control electrode of the electron gun determines the elec-tron beam intensity. If a pulse cosine waveform voltage is applied to this electrode, a cosine waveform electron beam pulse...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
0
36d5affc-eab0-46a0-9b85-bc5196bdd60f
1 nanosecond. Some primary investigations have been performed in some references, such as the f ormation of a bunched elec- tron beam at the e lectron cooler of CSRm [8], d ouble - bunch of electrons [9], and a longitudinal multi-bunch chain of e lectron s [10]. Some electron cooling experiments using a bunched ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
0
b53043ed-fbc0-43a2-90f1-727cec6a93a2
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP4654 2280 MC4.A11: Hadron accelerators: Beam CoolingWEP4654 WEP: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
0
095752e1-2d0a-4504-be53-2aa1f0d2b5e1
SYNCHRONIZATION OF THE ELEC- TRON BEAM AND THE ION BEAM The basic requirement for electron cooling is that the electron beam overlaps with the ion beam. In the longitu- dinal direction, the electron beam pulse should be longer than the ion beam pulse. The length of the ion beam bunch will decrease during the cooli...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
1
78e917db-358e-475f-aac0-4a9be396ab53
tions of the electron beam and ion beam in the cooling sec- tion of the electron cooling device. The beam position monitor at the entrance can be used to measure the flight time of the electron beam reaching the electron cooling section, while the beam position monitor at the exit can be used to measure the flight...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
1
e49379e3-3f4b-4905-9084-df0f6faf3850
tance from the electron gun's cathode to the entrance of the cooling section, where the beams overlap. The electron beam also takes time to travel through this region. Several beam position monitors are installed in the stor- age ring to measure the position of the ion beam. When the ion beam passes through the bea...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
1
520faf7b-e77e-4a13-8083-7dc4fd34d07a
power supply. These two parameters are set in the synchro- nous control system. VOLTAGE ON THE CONTROL ELEC- TRODE OF THE ELECTRON GUN In electron cooling, the cooling force is proportional to the electron density, while the cooling time is inversely proportional to the electron density. When the anode volt- age o...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
1
d5c7ea9b-745e-45d0-995e-0639fe783282
mains constant over time, the pulsed electron beam current is also constant, producing a uniform pulsed current. How- ever, if the amplitude of the voltage applied to the control electrode varies over time, the pulsed current also changes. When the amplitude of the applied pulsed voltage follows a certain regular sha...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
1
abf19b0d-10e3-4cab-8ceb-1957d51eff3e
the cooling section is 53 nanoseconds. The path length from the exit of the cooling section to the bottom of the collector is 2 .262 m. The flight time of the electron beam from the exit of the cooling section to the collector is 62 nanoseconds. The path length from the beam position monitor (BD22PXY1), which is ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
1
9ea4fc02-2525-488a-b558-bb7cb4a96f97
7.963 m. The flight time of the ion beam from the exit of the cooling section to the beam position monitor (BD24PXY1) is 220.6 nanoseconds. SYNCHRONIZED IMPLEMENTATION SCHEME A beam position monitor in the storage ring serves as the probe to measure the time signal of the ion beam pulse reaching that position....
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
1
0288c847-5f16-4324-a032-8f165ec71fe1
the beam position detector at the entrance of the electron cooling section is mea sured. And then, the flight time of the electron beam pulse after the electron gun was triggered to reach the beam position detector at the entrance of the electron cooling section is measured. In this measurement, the response time...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
1
be1f2ac7-bed0-4eec-9a68-b214d70e0353
The time relationship between the ion pulse and electron pulse was established according to these measurements, and the delay time from the trigger to the generation of the electron pulse was determined. Finally, according to the measurement results, the delay time was finely tuned and set previously. The longitu...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
2
200dadae-6778-4974-a915-25b76aca9a72
The electron beam departs from the cathode surface of the electron gun, passes through a solenoid and a toroid, and merges and overlaps with the ion beam in the cooling section. After interaction, the electron beam separates from the ion beam and then pass es through another toroid, a de- celerating section, and rea...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
2
1b236d3c-3c62-404a-90c4-6aaacd09e9c8
beam pulse. The path distance is approximately 76 meters from the beam position m onitor at the entrance of the cool- ing section. The ion beam signal obtained from this moni- tor is amplified and processed as a trigger signal, which is transmitted through an optical fiber to the high -voltage power supply control sy...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
2
c1f040c9-cc02-4386-a3d2-ac893076c8f7
conversion time, optic al fiber transmission time, trigger signal electro -optical conversion time, high -voltage power supply response time, high- voltage switch response time, and electron gun response time, etc. Comparing the flight time difference between the ion beam and the electron beam at the beam positio...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
2
c7cdf628-cdd9-4b0f-b2f4-2486640d490e
tron beam in the cooling section, the electron beam and the ion beam separate. The electron beam passes through a to-roid, a deceleration section, and reaches the collector. And the ion beam continues to rotate in the storage ring. The flight time of the electron beam from the beam po- sition monitor at the exit of...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
2
a64bd45e-68e8-47cd-84d8-7680c6b2892f
ence at different path distances. The path length experi- enced by electrons and ions during their respective move- ments is fixed and measurable. If the ion beam and electron beam depart from the same position, the flight time is fixed. When the difference be- tween the measurement results and the theoretical value...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP4654.pdf
2