command stringlengths 2 75 | syntax stringlengths 0 289k | hierarchy_level stringlengths 0 6.91k | description stringlengths 0 45.2k | options listlengths 0 499 | required_privilege_level stringlengths 0 330k | release_information stringlengths 0 3.14k | related_documentation listlengths 0 22 |
|---|---|---|---|---|---|---|---|
cpu-factor (Dampen Options) | cpu-factor cpu-factor; | [edit event-options event-script dampen dampen-options],
[edit event-options event-script file filename dampen dampen-options],
[edit system scripts commit dampen dampen-options],
[edit system scripts op dampen dampen-options],
[edit system scripts op file filename dampen dampen-options] | Slow down the operation of scripts executed on the device based on how heavily the CPU is being used.
Script dampening is initiated when CPU use exceeds the value specified using the cpu-factor statement.
Junos OS then executes the number of lines of script specified using the line-interval statement and
then pauses sc... | [
{
"name": "cpu-factor",
"desc": "Specify the CPU use factor at which script execution is slowed down. Range: 0 through 100 Default: 20"
}
] | maintenance—To view or add this statement in the configuration. | Statement introduced in Junos OS Release 14.1. | [
"Dampen Script Execution"
] |
cpu-load-threshold | cpu-load-threshold percentage; | [edit interfaces interface-name services-options session-limit] | Regulate the usage of CPU resources on services cards. When the CPU usage exceeds the configured
value (percentage of the total available CPU resources), the system reduces the rate of new sessions so
that the existing sessions are not affected by low CPU availability. The CPU utilization is constantly
monitored, and i... | [
{
"name": "percentage",
"desc": "Percentage of total available CPU resources."
}
] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced in Release 13.2.
Support added in Junos OS Release 19.3R2for Next Gen Services on MX Series routers MX240, MX480
and MX960 with the MX-SPC3 services card. | [] |
cpu-throttle (Next Gen Services) | cpu-throttle {
percentage percent;
} | [edit services screen] | Specify the services card CPU utilization percentage that triggers the installation of a dynamic filter on
the PFEs of the line cards for suspicious activity. The dynamic filter drops the suspicious traffic.
In addition to this threshold, at least one of the following conditions is required to trigger the installation
... | [
{
"name": "percentage percent",
"desc": "The CPU utilization percentage. Range: 1 through 100 Default: 90"
}
] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 19.3R2. | [
"Configuring Network Attack Protection With IDS Screens for Next Gen Services"
] |
craft-lockout | craft-lockout {
alarm {
interface-type {
link-down (red | yellow | ignore);
}
}
container-devices {
device-count number;
}
}
fpc slot {
pic pic-number {
fibre-channel {
port-range {
port-range... | [edit chassis] | Disable the physical operation of the craft interface front panel. | [] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced in Junos Release 11.3. | [
"Configuring the Junos OS to Disable the Physical Operation of the Craft Interface"
] |
crb-proxy-mac | crb-proxy-mac {
family {
inet IPv4-proxy-MAC-address;
inet6 IPv6-proxy-MAC-address;
}
} | [edit protocols l2-learning] | Enable this statement on Ethernet VPN (EVPN) leaf devices that act as Layer 2 (L2) gateways to manage
learning and aging for IPv4 Address Resolution Protocol (ARP) and IPv6 Neighbor Discovery Protocol
(NDP) entries.
After you enable the crb-proxy-mac option on an EVPN provider edge (PE) leaf device, the leaf device
sta... | [
{
"name": "inet IPv4-proxy-MAC-address",
"desc": "Configure the IPv4 proxy MAC address. The device uses this address to send ARP requests toward attached CE devices. This address must be the same on all leaf nodes."
},
{
"name": "inet6 IPv6-proxy-MAC-address",
"desc": "Configure the IPv6 proxy M... | interface—To view this statement in the configuration
interface-control—To add this statement to the configuration | Statement introduced in Junos OS Release and Junos OS Evolved Release 21.2R1. | [] |
create-new-ucast-tunnel | create-new-ucast-tunnel; | [edit routing-instances routing-instance-name provider-tunnel ingress-replication],
[edit routing-instances routing-instance-name provider-tunnel selective group address source
source-address ingress-replication] | One of two modes for building unicast tunnels when ingress replication is configured for the provider
tunnel. When this statement is configured, each time a new destination is added to the multicast
distribution tree, a new unicast tunnel to the destination is created in the ingress replication tunnel. The
new tunnel i... | [] | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 10.4. | [
"Example: Configuring Ingress Replication for IP Multicast Using MBGP MVPNs"
] |
create-req | create-req {
alarm-threshold (Security GPRS) {
forward number;
reverse number;
}
drop-threshold (Security GPRS) {
forward number;
reverse number;
}
} | [edit security gtp profile profile-name path-rate-limit message-type] | Configure the create-req parameter to limit or restrict the number of packets per second for the GPRS
tunneling protocol (GTP) create request.
From Junos OS Release 20.4R1 onwards, the [edit security gprs gtp profile profile-name path-rate-limit
message-type] hierarchy level is replaced by [edit security gtp profile p... | [
{
"name": "alarm-threshold",
"desc": "To set alarm threshold for path rate limiting."
},
{
"name": "drop-threshold",
"desc": "To set drop threshold for path rate limiting."
}
] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 12.1X45-D10. | [
"Understanding Path Rate Limiting for GTP Control Messages",
"Example: Limiting the Message Rate and Path Rate for GTP Control Messages"
] |
credibility | credibility {
direct;
isis-level-1;
isis-level-2;
ospf;
static;
unknown;
} | [edit logical-systems logical-system-name protocols mpls traffic-engineering database export],
[edit protocols mpls traffic-engineering database export] | Configure preference values for entries from BGP-TE to the traffic engineering database. A protocol with
a higher credibility value is preferred over a protocol with a lower credibility value.
The credibility order for the BGP-TE protocols is as follows:
•
Unknown—80
•
OSPF—81
•
ISIS Level 1—82
•
ISIS Level 2—83
•
Stat... | [
{
"name": "direct",
"desc": "Entries sourced from directly connected links."
},
{
"name": "isis-level-1",
"desc": "Entries sourced from IS-IS Level 1."
},
{
"name": "isis-level-2",
"desc": "Entries sourced from IS-IS Level 2."
},
{
"name": "ospf",
"desc": "Entries sourced... | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 14.2. | [] |
credit (Interfaces) | credit {
interval number;
} | [edit interfaces interface-name radio-router] | This parameter controls credit-based scheduling parameters and includes an interval option to set the
grant rate interval to a value between 1–60 seconds. | [] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 10.1. | [
"Understanding Interfaces"
] |
critical-event (Process) | critical-event {
threshold process name memory-limit value ;
action [snmp-trap | live-core | (terminate-process| terminate-process-force)];
} | [edit system monitor memory process] | Indicates an event that, if left unchecked, may result in serious loss of service or interruption of traffic.
You can specify the process threshold value for specific processes and their memory limit. When the
threshold is crossed, you can configure the action to be performed. For instance, you can specify the
process ... | [
{
"name": "threshold",
"desc": "Specifies the process threshold level for a minor event. You must specify the process name and the memory limit for the process. memory-limit - Specifies the permissible memory limit for the process after which the minor event is triggered. Range: 1 through 65535 MB"
},
... | system—To view this statement in the configuration.
system-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 20.1. | [
"System Log Overview",
"System Log Explorer"
] |
critical-event (System) | critical-event {
threshold swap-usage value ;
action [snmp-trap | live-vmcore | (RE-restart| RE-switchover)];
} | [edit system monitor memory system] | Indicates an event that, if left unchecked, may result in serious loss of service or interruption of traffic.
At the system level you can monitor the overall free pages (cache and free pages), kernel memory
allocations and compare them with threshold values. You can also monitor the swap usage and specify
the threshold... | [
{
"name": "threshold",
"desc": "Specifies the process threshold level for a minor event. You must specify the process name and the memory limit for the process."
},
{
"name": "swap-usage",
"desc": "Specifies the swap usage in percentage."
},
{
"name": "action",
"desc": "Specifies the... | system—To view this statement in the configuration.
system-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 20.1. | [
"System Log Overview",
"System Log Explorer"
] |
crl (Adaptive Services Interface) | crl {
disable on-download-failure;
refresh-interval number-of-hours;
url {
url-name;
password;
}
} | [edit security pki ca-profile ca-profile-name revocation-check] | Configure the certificate revocation list (CRL). A CRL is a time-stamped list identifying revoked
certificates, which is signed by a CA and made available to the participating IPsec peers on a regular
periodic basis. | [
{
"name": "disable on-download-failure",
"desc": "Permit the authentication of the IPsec peer when the CRL is not downloaded."
},
{
"name": "password",
"desc": "Password to access the URLs."
},
{
"name": "refresh-interval number-of-hours",
"desc": "Time interval, in hours, between CR... | admin—To view this statement in the configuration.
admin-control—To add this statement to the configuration | Statement introduced in Junos OS Release 8.1. | [
"Configuring the Certificate Revocation List"
] |
crl (Encryption Interface) | crl file-name; | [edit security certificates] | (Encryption interface on M Series and T Series routers and EX Series switches only) Configure the
certificate revocation list (CRL). A CRL is a time-stamped list identifying revoked certificates, which is
signed by a CA and made available to the participating IPsec peers on a regular periodic basis. | [
{
"name": "file-name",
"desc": "Specify the file from which to read the CRL."
}
] | admin—To view this statement in the configuration.
admin-control—To add this statement to the configuration | Statement introduced before Junos OS Release 7.4. | [
"Configuring the Certificate Authority Properties for an ES PIC"
] |
crl (Security) | crl {
disable {
on-download-failure;
}
refresh-interval hours;
url url-name;
} | [edit security pki ca-profile ca-profile-name revocation-check] | Configure the certificate revocation list (CRL). A CRL is a time-stamped list identifying revoked
certificates, which is signed by a CA and made available to the participating IPsec peers on a regular
periodic basis. | [
{
"name": "disable on-download-",
"desc": ""
},
{
"name": "failure",
"desc": "(Optional) Override the default behavior and permit certificate verification even if the CRL fails to download."
},
{
"name": "refresh-interval hours",
"desc": "Specify the amount of time interval in hours ... | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 8.5.
disable option is introduced in Junos OS Release 9.0. | [
"Basic Elements of PKI in Junos OS"
] |
crl | crl {
disable disable;
if-not-present (allow | drop);
ignore-hold-instruction-code ignore-hold-instruction-code;
} | [edit services ssl initiation profile profile-name actions]
[edit services ssl proxy profile profile-name actions] | Specify certificate revocation actions.
CRL validation on SRX Series Firewall involves checking for revoked certificates from servers. You can
enable or disable the CRL validation to meet your specific security requirements. You can allow or drop
the sessions when a CRL information is not available.
To enhance securit... | [
{
"name": "disable",
"desc": "Disable CRL validation."
},
{
"name": "if-not-present",
"desc": "Specify an action if CRL information is not present. Values:"
},
{
"name": "allow",
"desc": "Allow session if CRL information is not present."
},
{
"name": "drop",
"desc": "Dro... | system | Statement introduced in Junos OS Release 15.1X49-D30. This statement is supported in the SRX340,
SRX345, SRX550M, SRX1500, SRX4100, SRX4200, SRX5400, SRX5600, and SRX5800 devices and
vSRX Virtual Firewall instances. | [
"Working with the Certificate Revocation Lists for SSL Proxy"
] |
cross-connect | cross-connect {
cross-connect-name {
physical-interface {
hsxe0 {
vlan-id vlan-id;
}
hsxe1 {
vlan-id vlan-id;
}
}
virtual-network-function vnf-name {
interfaceinterface-name;
vlan-id vlan-... | [edit vlans] | Connects any two VNF interfaces, VLANs on physical interfaces such as hsxe0 and hsxe1, and also
provides features such as unconditional cross-connect, VLAN-based cross-connect, cross-connect of
native VLAN traffic, and cross-connect with operations such as PUSH, POP, and SWAP. | [
{
"name": "virtual-network-functions vnf-name",
"desc": "Name of the VNF instance."
},
{
"name": "cross-connect-name",
"desc": "Name of the cross-connect."
},
{
"name": "vlan-id",
"desc": "Virtual LAN identifier."
}
] | set—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 15.1X53-D47. | [
"Configuring Cross-connect"
] |
cross-connect-ccm | cross-connect-ccm; | [edit protocols oam ethernet connectivity-fault-management action-profile action-profile-name
event ais-trigger-condition] | Configure the defect condition that raises an alarm indication signal when any cross-connect continuity
check messages (CCMs) are received by the MEP. | [] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 14.2. | [
"Ethernet Alarm Indication Signal (ETH-AIS) Function Overview",
"Configuring ETH-AIS on a CFM MEP"
] |
cryptographic-address | cryptographic-address {
key-length number;
key-pair pathname;
} | [edit protocols neighbor-discovery secure] | Configure parameters for cryptographically generated addresses for Secure Neighbor Discovery.
The Secure Neighbor Discovery (SEND) Protocol uses cryptographically generated addresses (CGAs), as
defined in RFC 3972, Cryptographically Generated Addresses, to ensure that the sender of a Neighbor
Discovery Protocol (NDP) m... | [] | routing level—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.3. | [
"Example: Configuring Secure IPv6 Neighbor Discovery",
"Understanding Secure IPv6 Neighbor Discovery"
] |
csds | csds {
node-instance node-instance-id {
gateway-ip gateway-ip;
host-ip host-ip;
ip-prefix-range ip-prefix-range;
}
} | [edit system] | Configures the Ubuntu host servers with the IP prefix range to provision the JDM in Connected Security
Distributed Services (CSDS) architecture. JDM installation assigns the first IP in the range to the JDM
container and the subsequent IPs to the vSRX Virtual Firewalls. Run this command on MX Series Junos
Node Unifier ... | [
{
"name": "node-instance",
"desc": "Add new node instance. Set the host instance ID for the baremetal server host. Range: 0-100"
},
{
"name": "gateway-ip",
"desc": "Provide gateway IP for JDM and vSRX."
},
{
"name": "host-ip",
"desc": "Provide host IP address."
},
{
"name": ... | system—To view this statement in the configuration.
system-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 24.4R1. | [
"Junos Device Manager for CSDS"
] |
cspf-backoff-time | cspf-backoff-time seconds; | [edit logical-systems name protocols mpls],
[edit logical-systems name routing-instances name protocols mpls],
[edit logical-systems name tenants name routing-instances name protocols mpls],
[edit logical-systems name protocols mpls label-switched-path],
[edit logical-systems name routing-instances name protocols mpls... | The statement enables you to delay the CSPF by configured number of seconds, on receiving bandwidth
unavailable PathErr on PSB2. If the configured value is zero, then the CSPF starts immediately for PSB2,
when bandwidth-unavailable PathErr is received. If the statement is not configured, the default
exponential back-of... | [
{
"name": "seconds",
"desc": "CSPF delay time in seconds."
}
] | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 20.3R1 and Junos OS Evolved Release 20.3R1 on all
platforms. | [] |
cts | cts (ignore | normal | require); | [edit interfaces interface-name serial-options dce-options],
[edit interfaces interface-name serial-options dte-options] | For EIA-530 and V.35 interfaces only, configure the from-DCE signal, clear-to-send (CTS). | [
{
"name": "ignore",
"desc": "The from-DCE signal is ignored."
},
{
"name": "normal",
"desc": "Normal CTS signal handling as defined by the TIA/EIA Standard 530."
},
{
"name": "require",
"desc": "The from-DCE signal must be asserted."
}
] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced before Junos OS Release 7.4. | [
"Configuring the Serial Signal Handling"
] |
cts-polarity | cts-polarity (negative | positive); | [edit interfaces interface-name serial-options] | Configure CTS signal polarity. | [
{
"name": "positive",
"desc": "Positive signal polarity."
},
{
"name": "negative",
"desc": "Negative signal polarity."
}
] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced before Junos OS Release 7.4. | [
"Configuring Serial Signal Polarities"
] |
ctxt-history | ctxt-history {
file {
files number of files;
size file size;
}
} | [edit protocols l2-learning] | Configure your device to capture context history for Layer 2 address learning issues in Ethernet VPN
(EVPN) networks. | [
{
"name": "file",
"desc": "Configure the number of files. Range: 0 to 100 Default: 3 Disable context history file system logging with the following configuration: set protocols l2-learning ctxt-history files file 0"
},
{
"name": "size",
"desc": "Configure the file size. Range: 20 to 100 MB ... | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 24.2R1. | [] |
current-hop-limit (Dynamic Router Advertisement) | current-hop-limit number; | [edit dynamic-profiles protocols router-advertisement interface interface-name] | Default value placed in the hop count field of the IP header for outgoing packets. | [
{
"name": "number",
"desc": "Hop limit. A value of 0 means the limit is unspecified by this router."
}
] | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 10.1. | [
"IPv6 WAN Link Addressing with NDRA",
"Dynamic Router Advertisement Configuration Overview"
] |
current-hop-limit | current-hop-limit number; | [edit logical-systems logical-system-name protocols router-advertisement interface interface-
name],
[edit protocols router-advertisement interface interface-name] | Set the default value placed in the hop count field of the IP header for outgoing packets. | [
{
"name": "number",
"desc": "Hop limit. A value of 0 means the limit is unspecified by this router."
}
] | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced before Junos OS Release 7.4. | [
"Example: Configuring IPv6 Interfaces and Enabling Neighbor Discovery"
] |
custom-attack | custom-attack attack-name {
attack-type (Security Anomaly) {
anomaly {
direction (any | client-to-server | server-to-client);
service service-name;
shellcode (all | intel | no-shellcode | sparc);
test test-condition;
}
chain {
expre... | [edit security idp]
[edit tenants tenant-name security idp] | Configure custom attack objects to detect a known or unknown attack that can be used to compromise
your network. | [
{
"name": "attack-name",
"desc": "Name of the custom attack object. The maximum number of characters allowed for a"
}
] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Statement modified in Junos OS Release 9.3. | [] |
custom-attack-group | custom-attack-group custom-attack-group-name {
group-members [attack-or-attack-group-name];
} | [edit security idp]
[edit tenants tenant-name security idp] | Configure custom attack group. A custom attack group is a list of attacks that would be matched on the
traffic if the group is selected in a policy. | [
{
"name": "custom-attack-group-name",
"desc": "Name of the custom attack group."
}
] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.3. | [] |
custom-attack-groups (Security IDP) | custom-attack-groups attack-group-name; | [edit security idp idp-policy policy-name rulebase-exempt rule rule-name match attacks]
[edit security idp idp-policy policy-name rulebase-ips rule rule-name match attacks] | Specify a name for the custom attack group. | [
{
"name": "attack-group-name",
"desc": "Name of the custom attack group."
}
] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.2. | [] |
custom-attacks | custom-attacks [attack-name]; | [edit security idp idp-policy policy-name rulebase-exempt rule rule-name match attacks],
[edit security idp idp-policy policy-name rulebase-ips rule rule-name match attacks] | Select custom attacks defined under [edit security idp custom-attack] by specifying their names. | [
{
"name": "attack-name",
"desc": "Name of the new custom attack object."
}
] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.2. | [] |
custom-block-message | custom-block-message value; | [edit security utm default-configuration]
[edit security utm feature-profile web-filtering surf-control-integrated profile profile-name]
[edit security utm feature-profile web-filtering juniper-enhanced profile profile-name] | Enter a custom message to be sent when HTTP requests are blocked. | [] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | The Surf-Control feature is not supported from Junos OS Release 15.1X49-D10 onwards. For previous
releases, statement introduced in Junos OS Release 9.5.
Statement introduced in Junos OS Release 11.4 .
The [edit security utm default-configuration] hierarchy level is introduced in Junos OS Release 18.2R1. | [] |
custom-ciphers | custom-ciphers [dhe-rsa-with-3des-ede-cbc-sha | dhe-rsa-with-aes-128-cbc-sha | dhe-rsa-with-
aes-128-cbc-sha256 |
dhe-rsa-with-aes-128-ccm8-sha256 | dhe-rsa-with-aes-128-ccm-sha256 | dhe-rsa-with-aes-128-gcm-
sha256 |
dhe-rsa-with-aes-256-cbc-sha | dhe-rsa-with-aes-256-cbc-sha256 | dhe-rsa-with-aes-256-ccm8-
sha256 |... | [edit services ssl proxy profile profile-name]
[edit services ssl termination profile profile-name]
[edit services ssl initiation profile profile-name] | Configure custom cipher for an SSL profile.
Custom ciphers allow you to define your own cipher list. If you do not want to use one of the three
categories (strong, medium, or week) of preferred ciphers, you can select ciphers from each of the
categories to form a custom cipher set.
To configure custom ciphers, you must... | [
{
"name": "dhe-rsa-with-3des-ede-cbc-sha",
"desc": ""
},
{
"name": "DHE/rsa, 3des ede/cbc, sha hash",
"desc": ""
},
{
"name": "dhe-rsa-with-aes-128-cbc-sha",
"desc": ""
},
{
"name": "DHE/rsa, 128 bit aes/cbc, sha hash",
"desc": ""
},
{
"name": "dhe-rsa-with-aes-12... | services—To view this statement in the configuration.
services-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 12.1X44-D10.
This statement is supported in the SRX340, SRX345, SRX380, SRX550M, SRX1500, SRX4100,
SRX4200, SRX5400, SRX5600, and SRX5800 devices and vSRX Virtual Firewall instances. Options to
support Elliptic Curve Digital Signature Algorithm (ECDSA) added in Junos OS Release ... | [
"SSL Proxy Overview",
"Configuring SSL Forward Proxy",
"Enabling Debugging and Tracing for SSL Proxy"
] |
custom-message (Security Content Filtering) | custom-message message; | [edit security utm default-configuration]
[edit security utm feature-profile content-filtering profile profile-name notification-options] | Custom message notifications are generally used when content is blocked by the content filter. | [] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.5.
The [edit security utm default-configuration] hierarchy level is introduced in Junos OS Release 18.2R1. | [
"Content Filtering Overview"
] |
custom-message (Security Email Notify) | custom-message message; | [edit security utm feature-profile anti-virus juniper-express-engine pattern-update email-notify]
[edit security utm feature-profile anti-virus kaspersky-lab-engine pattern-update email-notify]
[edit security utm feature-profile anti-virus sophos-engine pattern-update email-notify]
[edit security utm default-configurat... | You can configure the device to notify a specified administrator when patterns are updated. This is an e-
mail notification with a custom message. | [] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | The Express and Kaspersky antivirus feature is not supported from Junos OS Release 15.1X49-D10
onwards. For previous releases, statement introduced in Junos OS Release 9.5. Support for Sophos
engine added in Junos OS Release 11.1.
The [edit security utm default-configuration] hierarchy level is introduced in Junos OS R... | [] |
custom-message (Security Fallback Block) | custom-message message; | [edit security utm default-configuration]
[edit security utm feature-profile anti-virus juniper-express-engine profile profile-name
notification-options fallback-block]
[edit security utm feature-profile anti-virus kaspersky-lab-engine profile profile-name
notification-options fallback-block]
[edit security utm featu... | Custom message notifications are mainly used in file replacement or in a response message when the
antivirus scan result is to drop the file. | [] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | The Express and Kaspersky antivirus feature is not supported from Junos OS Release 15.1X49-D10
onwards. For previous releases, statement introduced in Junos OS Release 9.5. Support for Sophos
engine added in Junos OS Release 11.1.
The [edit security utm default-configuration] hierarchy level is introduced in Junos OS R... | [] |
custom-message (Security Fallback Non-Block) | custom-message message; | [edit security utm default-configuration]
[edit security utm feature-profile anti-virus juniper-express-engine profile profile-name
notification-options fallback-non-block]
[edit security utm feature-profile anti-virus kaspersky-lab-engine profile profile-name
notification-options fallback-non-block]
[edit security u... | Custom message notifications are mainly used in file replacement or in a response message when the
antivirus scan result is to drop the file. | [] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | The Express and Kaspersky antivirus feature is not supported from Junos OS Release 15.1X49-D10
onwards. For previous releases, statement introduced in Junos OS Release 9.5. Support for Sophos
engine added in Junos OS Release 11.1.
The [edit security utm default-configuration] hierarchy level is introduced in Junos OS R... | [] |
custom-message (Security Virus Detection) | custom-message message; | [edit security utm default-configuration]
[edit security utm feature-profile anti-virus juniper-express-engine profile profile-name
notification-options virus-detection]
[edit security utm feature-profile anti-virus kaspersky-lab-engine profile profile-name
notification-options virus-detection]
[edit security utm fea... | Custom message notifications are mainly used in file replacement or in a response message when the
antivirus scan result is to drop the file. | [] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | The Express and Kaspersky antivirus feature is not supported from Junos OS Release 15.1X49-D10
onwards. For previous releases, statement introduced in Junos OS Release 9.5. Support for Sophos
engine added in Junos OS Release 11.1.
The [edit security utm default-configuration] hierarchy level is introduced in Junos OS R... | [] |
custom-message (Security Web Filtering) | custom-message custom-message; | [edit security utm feature-profile web-filtering juniper-local profile profile-name]
[edit security utm feature-profile web-filtering juniper-enhanced profile profile-name]
[edit security utm feature-profile web-filtering websense-redirect profile profile-name]
[edit logical-systems name security utm feature-profile we... | You can reference the custom-page type custom-message object at the Web filtering profile level. If the
category action is block or quarantine and no custom-message is configured in the category, the custom-
message under the profile will take effect. | [
{
"name": "custom-message",
"desc": "Specify the custom message object."
}
] | security | Statement introduced in Junos OS Release 20.4R1. | [] |
custom-message-subject (Security Email Notify) | custom-message-subject message-subject; | [edit security utm feature-profile anti-virus juniper-express-engine pattern-update email-notify]
[edit security utm feature-profile anti-virus kaspersky-lab-engine pattern-update email-notify]
[edit security utm feature-profile anti-virus sophos-engine pattern-update email-notify]
[edit security utm default-configurat... | You can configure the device to notify a specified administrator when patterns are updated. This is an e-
mail notification with a custom message and a custom subject line. | [] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | The Express and Kaspersky antivirus feature is not supported from Junos OS Release 15.1X49-D10
onwards. For previous releases, statement introduced in Junos OS Release 9.5. Support for Sophos
engine added in Junos OS Release 11.1.
The [edit security utm default-configuration] hierarchy level is introduced in Junos OS R... | [] |
custom-message-subject (Security Fallback Block) | custom-message-subject message-subject; | [edit security utm default-configuration]
[edit security utm feature-profile anti-virus juniper-express-engine profile profile-name
notification-options fallback-block]
[edit security utm feature-profile anti-virus kaspersky-lab-engine profile profile-name
notification-options fallback-block]
[edit security utm feat... | Custom message notifications are mainly used in file replacement or in a response message when the
antivirus scan result is to drop the file. As part of a custom message, you can customize the message
subject line. | [] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | The Express and Kaspersky antivirus feature is not supported from Junos OS Release 15.1X49-D10
onwards. For previous releases, statement introduced in Junos OS Release 9.5. Support for Sophos
engine added in Junos OS Release 11.1.
The [edit security utm default-configuration] hierarchy level is introduced in Junos OS R... | [] |
custom-message-subject (Security Fallback Non-Block) | custom-message-subject message-subject; | [edit security utm default-configuration]
[edit security utm feature-profile anti-virus juniper-express-engine profile profile-name
notification-options fallback-non-block]
[edit security utm feature-profile anti-virus kaspersky-lab-engine profile profile-name
notification-options fallback-non-block]
[edit security u... | Custom message notifications are mainly used in file replacement or in a response message when the
antivirus scan result is to drop the file. As part of a custom message, you can customize the message
subject line. | [] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | The Express and Kaspersky antivirus feature is not supported from Junos OS Release 15.1X49-D10
onwards. For previous releases, statement introduced in Junos OS Release 9.5. Support for Sophos
engine added in Junos OS Release 11.1.
The [edit security utm default-configuration] hierarchy level is introduced in Junos OS R... | [] |
custom-message-subject (Security Virus Detection) | custom-message-subject message-subject; | [edit security utm default-configuration]
[edit security utm feature-profile anti-virus juniper-express-engine profile profile-name
notification-options virus-detection]
[edit security utm feature-profile anti-virus kaspersky-lab-engine profile profile-name
notification-options virus-detection]
[edit security utm fea... | Custom message notifications are mainly used in file replacement or in a response message when the
antivirus scan result is to drop the file. As part of a custom message, you can customize the message
subject line. | [] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | The Express and Kaspersky antivirus feature is not supported from Junos OS Release 15.1X49-D10
onwards. For previous releases, statement introduced in Junos OS Release 9.5. Support for Sophos
engine added in Junos OS Release 11.1.
The [edit security utm default-configuration] hierarchy level is introduced in Junos OS R... | [] |
custom-objects | custom-objects {
custom-url-category object-name {
value [value];
}
custom-message {
name message-name;
type redirect-url | user-message;
content redirect-url by user| user-message by user;
}
filename-extension object-name {
value [value];
}
mime-patt... | [edit security utm]
[edit security utm default-configuration]
[edit logical-systems logical-system-name security utm]
[edit tenants tenant-name security utm] | Configure custom objects before configuring Content Security feature-profile features.
WARNING: Custom category does not take precedence over predefined categories
when it has the same name as one of the predefined categories. We do not recommend
having a custom category name be the same as the predefined category name... | [] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.5.
The [edit security utm default-configuration] hierarchy level introduced in Junos OS Release 18.2R1.
Support for configuration in logical systems introduced in Junos OS Release 18.3R1.
Support for configuration in tenant systems introduced in Junos OS Release 19.2R1. | [
"Unified Threat Management Overview"
] |
custom-options | custom-options {
banner-message string;
footer-bgcolor color;
footer-message string;
footer-text-color color;
form-header-bgcolor color;
form-header-message string;
form-header-text-color color;
form-reset-label label name;
form-submit-label label name;
header-bgcolor color;
... | [edit services captive-portal] | Specify the design elements of a captive portal login page. | [
{
"name": "banner-message",
"desc": "The first screen displayed before the captive portal login page is displayed—for"
},
{
"name": "footer-bgcolor",
"desc": "The hexadecimal color code for the color of the footer bar across the bottom of the"
},
{
"name": "captive portal login page",
... | routing—To view this statement in the configuration.
routing–control—To add this statement to the configuration. | Statement introduced in Junos OS Release 10.1. | [
"Designing a Captive Portal Authentication Login Page on Switches",
"Configuring Captive Portal Authentication (CLI Procedure)"
] |
custom-page | custom-page {
custom-page-file custom-page-file;
} | [edit security utm custom-objects custom-message name type] | You can create your own custom response pages for a URL that is configured with block or quarantine
actions in the Content Security Web filtering profile. The custom response pages can include predefined
page variables, your corporate branding, acceptable use policies, and links to your internal resources. | [
{
"name": "custom-page-file",
"desc": "Name of custom page file."
}
] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 20.4R1. | [] |
custom-page-file | custom-page-file custom-page-file; | [edit security utm custom-objects custom-message]
[edit logical-systems name security utm custom-objects custom-message],
[edit tenants name security utm custom-objects custom-message] | You can create your own custom response pages based on a predefined template HTML file for a URL
that is configured with block or quarantine actions in the Content Security Web filtering profile. By
default, Your security device provides a predefined HTML template file, which is saved at the local
folder /var/db/utm/ c... | [
{
"name": "custom-page-file",
"desc": "Name of custom page file."
}
] | security | Statement introduced in Junos OS Release 20.4R1. | [] |
custom-tag-string | custom-tag-string [string]; | [edit security utm default-configuration]
[edit security utm feature-profile anti-spam sbl profile profile-name] | Configure a custom string for identifying a message as spam. | [] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.5.
The [edit security utm default-configuration] hierarchy level is introduced in Junos OS Release 18.2R1. | [] |
custom-url-category | custom-url-category object-name {
value [value];
} | [edit security utm default-configuration]
[edit security utm custom-objects] | Use URL pattern lists to create Custom URL category lists. These are lists of patterns that bypass
scanning.
WARNING: Custom category does not take precedence over predefined categories
when it has the same name as one of the predefined categories. We do not recommend
having a custom category name be the same as the pr... | [
{
"name": "object-name",
"desc": "Name of the URL category-list object."
},
{
"name": "value value",
"desc": "Value of the URL category-list object. You can configure multiple values separated by"
}
] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.5.
The [edit security utm default-configuration] hierarchy level is introduced in Junos OS Release 18.2R1. | [
"Unified Threat Management Overview"
] |
customer-vlans | customer-vlans (id | native | range); | [edit vlans vlan-name dot1q-tunneling] | Limit the set of accepted customer VLAN tags to a range or to discrete values when mapping customer
VLANs to service VLANs. | [
{
"name": "id",
"desc": "Numeric identifier for a VLAN."
},
{
"name": "native",
"desc": "Accepts untagged and priority-tagged packets from access interfaces and assigns the configured"
},
{
"name": "range",
"desc": "Range of numeric identifiers for VLANs. On the QFX series, you can i... | system—To view this statement in the configuration.
system-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.3.
Option native introduced in Junos OS Release 9.6 for EX Series switches. | [
"Example: Setting Up Q-in-Q Tunneling on EX Series Switches",
"Configuring Q-in-Q Tunneling on EX Series Switches",
"Understanding Q-in-Q Tunneling and VLAN Translation"
] |
customization (SNMP) | customization {
ether-stats-ifd-only;
} | [edit snmp] | Customize SNMP behavior. | [
{
"name": "ether-stats-ifd-only",
"desc": "Stop exposing logical interfaces (IFLs) in the etherStatsTable. When this statement is configured, the output for the show snmp mib walk etherStatsTable command displays data for physical interfaces (IFDs) only."
}
] | snmp | Statement introduced in Junos OS Release 18.4R1. | [] |
cut-through | cut-through; | [edit forwarding-options] | Configures all the interfaces in the QFX series switch or QFabric to use cut-through forwarding mode
instead of store-and-forward mode. | [] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | [
"Layer 2 Forwarding Tables"
] | |
cvss-score | cvss-score
{
greater-than value;
less-than value;
} | [edit security idp dynamic-attack-group name filters] | The Common Vulnerability Scoring System (CVSS) score of attack is a free and open industry standard
for assessing the severity of computer system security vulnerabilities. CVSS attempts to assign severity
scores to vulnerabilities, allowing responders to prioritize responses and resources according to threats.
Scores r... | [
{
"name": "greater-than",
"desc": ""
},
{
"name": "value",
"desc": "Match when CVSS score is greater than the value specified. The value is a real number and can include decimal values. For example, the value 5.5 is a valid CVSS score. Range: 0 to 10"
},
{
"name": "less-than value",
... | security | Statement introduced in Junos OS Release 18.2R1. | [] |
cycle-time | cycle-time cycle-time-value; | [edit protocols oam ethernet connectivity-fault-management performance-monitoring sla-iterator-profiles
profile-name] | Configure the time (in milliseconds) taken between back-to-back transmissions of SLA frames for a
single connection. | [
{
"name": "cycle-time-value",
"desc": "Cycle time value in milliseconds."
}
] | Configure—To enter configuration mode.
Control—To modify any configuration. | Statement introduced in Junos OS Release 11.1. | [
"Configuring an Iterator Profile",
"Configure an Iterator Profile on a Switch (CLI Procedure)",
"D"
] |
dad-proxy | dad-proxy {
interface-restricted;
interface-unrestricted;
} | [edit dynamic-profiles name interfaces name unit name family inet6],
[edit dynamic-profiles name logical-systems name interfaces name unit name family inet6],
[edit interfaces name unit name family inet6] | DAD proxy on interface | [
{
"name": "interface-restricted",
"desc": "Enable DAD interface proxy restricted to interface"
},
{
"name": "interface-unrestricted",
"desc": "Enable DAD interface proxy unrestricted to interface"
}
] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 21.1R1
Option interface-unrestricted introduced in Junos OS Release 22.1R1 (on SRX Series and vSRX Virtual
Firewall 3.0 platform).
NOTE: You cannot configure both interface restricted and interface unrestricted modes
on the same interface simultaneously. | [] |
dampen (Protocols MVPN) | dampen minutes | [edit logical-systems logical-system--name protocols mvpn mvpn-mode spt-only source-active-
advertisement],
[edit logical-systems logical-system--name routing-instances instance-name protocols mvpn mvpn-
mode spt-only source-active-advertisement],
[edit routing-instances instance-name protocols mvpn mvpn-mode spt-only ... | Time to wait before re-advertising the source-active route (1 to 30 minutes). After traffic on the ingress
PE falls below the threshold set for "min-rate" on page 11163, this is length of time that resuming traffic
must continue to exceed the min-rate before the ingress PE can start re-advertising Source-Active A-D
rou... | [] | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 17.1. | [
"Configuring SPT-Only Mode for Multiprotocol BGP-Based Multicast VPNs"
] |
dampen | dampen {
dampen-options {
cpu-factor cpu-factor;
line-interval line-interval;
time-interval time-interval;
}
} | [edit event-options event-script],
[edit event-options event-script file filename],
[edit system scripts commit],
[edit system scripts op],
[edit system scripts op file filename] | Slow down the operation of SLAX and XSLT scripts executed on the device.
To dampen all enabled scripts of a given script type, configure the statement at the hierarchy level for
that script type. To dampen a single op or event script, configure the statement at the hierarchy level
where the script is configured. Script... | [] | maintenance—To view or add this statement in the configuration. | Statement introduced in Junos OS Release 14.1. | [
"Dampen Script Execution"
] |
dampen-options | dampen-options {
cpu-factor cpu-factor;
line-interval line-interval;
time-interval time-interval;
} | [edit event-options event-script dampen],
[edit event-options event-script file filename dampen],
[edit system scripts commit dampen],
[edit system scripts op dampen],
[edit system scripts op file filename dampen] | Slow down the operation of automation scripts executed on the device. | [] | maintenance—To view or add this statement in the configuration. | Statement introduced in Junos OS Release 14.1. | [
"Dampen Script Execution"
] |
damping (BFD Liveness Detection) | damping {
half-life-interval seconds;
increment increment;
max-suppress-time seconds;
reuse reuse;
suppress suppress;
} | [edit interfaces name aggregated-ether-options bfd-liveness-detection],
[edit dynamic-profiles name interfaces name aggregated-ether-options bfd-liveness-detection],
[edit dynamic-profiles name logical-systems name interfaces name aggregated-ether-options bfd-
liveness-detection] | Enable BFD session damping to dampen excess flap notifications from a BFD session that is going up
and down repeatedly. BFD session damping using a merit system where each flap adds to a merit value,
and once a BFD session reaches the configured merit value, notifications will be dampened. The merit
value decreases by ... | [
{
"name": "half-life-interval",
"desc": "Time duration before the accumulated merit value for a BFD session is reduced by half. Default: 30 seconds Range: 1 through 600 seconds"
},
{
"name": "increment",
"desc": "Increments applied to merit value for every flap Default: 1000 Range: 1000 thro... | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 23.4R1. | [] |
damping (Interfaces) | damping {
enable;
half-life seconds;
max-suppress seconds;
reuse number;
suppress number;
} | [edit interfaces interface--name],
[edit interfaces interface--range] | Limit the number of advertisements of the up and down transitions (flapping) on an interface. Each time
a transition occurs, the interface state is changed, which generates an advertisement to the upper-level
routing protocols. Damping helps reduce the number of these advertisements. Every time an interface
goes down, ... | [
{
"name": "enable",
"desc": "Enable damping on a per-interface basis. If damping is enabled on an interface, it is suppressed"
},
{
"name": "half-life seconds",
"desc": "Decay half-life. seconds is the interval after which the accumulated interface penalty"
},
{
"name": "max-suppress sec... | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 14.1. | [
"Damping Shorter Physical Interface Transitions"
] |
damping (Policy Options) | damping name {
disable;
half-life minutes;
max-suppress minutes;
reuse number;
suppress number;
} | [edit logical-systems logical-system-name policy-options],
[edit policy-options] | Define route flap damping properties to set on BGP routes. | [
{
"name": "disable",
"desc": "Disable damping on a per-prefix basis. Any damping state that is present in the routing table for"
},
{
"name": "half-life minutes",
"desc": "Decay half-life. minutes is the interval after which the accumulated figure-of-merit value"
},
{
"name": "max-suppre... | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced before Junos OS Release 7.4. | [
"Configuring BGP Flap Damping Parameters",
"Example: Configuring BGP Route Flap Damping Parameters",
"Example: Configuring BGP Route Flap Damping Based on the MBGP MVPN Address Family"
] |
damping (Protocols BGP) | damping; | [edit logical-systems logical-system-name protocols bgp],
[edit logical-systems logical-system-name protocols bgp family family],
[edit logical-systems logical-system-name protocols bgp family family],
[edit logical-systems logical-system-name protocols bgp group group-name],
[edit logical-systems logical-system-name p... | Enable route flap damping. BGP route flapping describes the situation in which BGP systems send an
excessive number of update messages to advertise network reachability information. Flap damping
reduces the number of update messages sent between BGP peers, thereby reducing the load on these
peers, without adversely aff... | [] | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced before Junos OS Release 7.4.
Support for flap damping at the address family level introduced in Junos OS Release 12.2. | [
"Examples: Configuring BGP Flap Damping",
"Example: Configuring BGP Route Flap Damping Based on the MBGP MVPN Address Family"
] |
data (FTP) | data {
dscp (alias | bits);
forwarding-class class-name;
} | [edit services cos application-profile profile-name ftp] | Set the appropriate dscp and forwarding-class value for FTP data.
Default
By default, the system will not alter the DSCP or forwarding class for FTP data traffic. | [] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.3. | [
"Configuring CoS Rules on Services PICs"
] |
data-channel | data-channel {
vlan number;
} | [edit protocols protection-group ethernet-ring ring-name] | For Ethernet ring protection, configure a data channel to define a set of VLAN IDs that belong to a ring
instance.
VLANs specified in the data channel use the same topology used by the ERPS PDU in the control
channel. Therefore, if a ring interface is blocked in the control channel, all traffic in the data channel is
a... | [
{
"name": "vlan number",
"desc": "Specify (by VLAN ID) one or more VLANs that belong to a ring instance."
}
] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 10.2.
Statement introduced in Junos OS Release 12.1 for EX Series switches.
Statement introduced in Junos OS Release 14.153-D10 for QFX Series switches. | [
"Ethernet Ring Protection Using Ring Instances for Load Balancing",
"Example: Configuring Load Balancing Within Ethernet Ring Protection for MX Series Routers",
"Example: Configuring Ethernet Ring Protection Switching on QFX Series and EX Series Switches",
"Supporting ELS",
"Configuring Ethernet Ring Protec... |
data-cores | data-cores data-number; | [edit chassis fpc slot-number pic pic-number adaptive-services service-package extension-
provider] | Configure data cores. Any cores not configured as either data or control cores are treated as user cores.
When the number of data cores is changed, the PIC reboots. | [
{
"name": "data-number",
"desc": "Number of data cores. Although it is not mandatory to dedicate any cores as data cores, it is"
}
] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.0. | [] |
data-encapsulation | data-encapsulation (disable | enable); | [edit logical-systems logical-system-name protocols msdp],
[edit logical-systems logical-system-name routing-instances routing-instance-name protocols
msdp],
[edit protocols msdp],
[edit routing-instances routing-instance-name protocols msdp] | Configure a rendezvous point (RP) using MSDP to encapsulate multicast data received in MSDP register
messages inside forwarded MSDP source-active messages.
Default
If you do not include this statement, the RP encapsulates multicast data. | [
{
"name": "disable",
"desc": "(Optional) Do not use MSDP data encapsulation."
},
{
"name": "enable",
"desc": "Use MSDP data encapsulation."
}
] | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced before Junos OS Release 7.4. | [
"Example: Configuring MSDP with Active Source Limits and Mesh Groups"
] |
data-fill | data-fill data; | [edit services monitoring rpm owner name test name] | Specify the contents of the data portion of Internet Control Message Protocol (ICMP) probes. The data-
fill statement is not valid with the http-get or http-metadata-get probe types. | [
{
"name": "data",
"desc": "A hexadecimal value; for example, 0-9, A-F."
}
] | system—To view this statement in the configuration.
system-control—To add this statement to the configuration. | Statement introduced before Junos OS Release 7.4.
Statement introduced in Junos OS Evolved Release 20.1R1. | [
"Understanding Using Probes for Real-Time Performance Monitoring on M, T, PTX, and MX Series",
"Routers",
"Configuring BGP Neighbor Discovery Through RPM",
"Configuring RPM Probes on M, MX and T Series Routers and EX Series Switches"
] |
data-fill-with zeros | data-fill-with-zeros; | [edit services rpm twamp client control-connection control-client-name test-session session-name] | If this statement is configured, then the contents of the test packet are zeros, if the statement is not
configured, then the data content is a pseudo-random number. | [] | system—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 15.1. | [
"Understanding Two-Way Active Measurement Protocol on Routers"
] |
data-flow-affinity | data-flow-affinity {
hash-key (layer-3 | layer-4);
} | [edit chassis fpc slot-number pic pic-number adaptive-services service-package extension-
provider] | Enable flow affinity distribution for packets over data CPUs on the PIC. Once enabled, the default
behavior distributing data packets changes from a round-robin distribution to a flow affinity distribution
based on a hash distribution. Adding or deleting this statement causes the PIC to reboot.
The remaining statements... | [] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.5. | [] |
data-format | data-format format; | [edit services flow-collector file-specification variant variant-number] | Specify the data format for a specific file format variant. | [
{
"name": "format",
"desc": "Data format. Specify flow-compressed as the data format."
}
] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced before Junos OS Release 7.4. | [
"Configuring File Formats"
] |
data-forwarding | data-forwarding {
receiver {
install;
mode (proxy | transparent);
(source-list | source-vlans) vlan-list;
translate;
}
source {
groups group-prefix;
}
} | [edit protocols igmp-snooping vlan vlan-name]
[edit logical-systems name protocols igmp-snooping vlan vlan-name] | Configure a data-forwarding VLAN as a multicast source VLAN (MVLAN) or a receiver VLAN using the
multicast VLAN registration (MVR) feature.
You can configure a data-forwarding VLAN as either a multicast source VLAN (an MVLAN) or a multicast
receiver VLAN (an MVR receiver VLAN), but not both.
•
When you configure an MVR... | [] | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.6. | [
"Understanding Multicast VLAN Registration",
"Example: Configuring Multicast VLAN Registration on EX Series Switches Without ELS",
"Configuring Multicast VLAN Registration on EX Series Switches"
] |
data-length | data-length {
match (equal | greater-than | less-than | not-equal);
value tcp-data-length;
} | [edit security idp custom-attack attack-name attack-type signature protocol udp],
[edit security idp custom-attack attack-name attack-type signature protocol icmp],
[edit security idp custom-attack attack-name attack-type signature protocol icmpv6],
[edit security idp custom-attack attack-name attack-type signature pro... | Specify the number of bytes in the data payload. In the TCP header, for SYN, ACK, and FIN packets, this
field should be empty. | [
{
"name": "match (equal | greater-than | less-than | not-equal)",
"desc": "Match an operand."
},
{
"name": "value data-length",
"desc": "Match the number of bytes in the data payload."
}
] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.3. | [] |
data-mdt-reuse | data-mdt-reuse; | [edit logical-systems logical-system-name routing-instances routing-instance-name provider-
tunnel pim mdt],
[edit logical-systems logical-system-name routing-instances routing-instance-name provider-
tunnel family inet | inet6 mdt],
[edit routing-instances routing-instance-name provider-tunnel family inet | inet6 mdt... | Enable dynamic reuse of data MDT group addresses. | [] | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 10.0. In Junos OS Release 17.3R1, the mdt hierarchy was
moved from provider-tunnel to the provider-tunnel family inet and provider-tunnel family inet6 hierarchies as
part of an upgrade to add IPv6 support for default MDT in Rosen 7, and data MDT for Rosen 6 and
Rosen 7. The prov... | [
"Example: Enabling Dynamic Reuse of Data MDT Group Addresses"
] |
data-rate | data-rate weight; | [edit interfaces interface-name unit logical-unit-number radio-router] | Configure the weight of the resource factor when calculating an effective data rate. | [
{
"name": "weight",
"desc": "Factor used to calculate data rate."
}
] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced in Release 10.2 of Junos OS . | [
"Configuring PPPoE-Based Radio-to-Router Protocols"
] |
data-record-fields | data-record-fields {
include-policy-map-name;
source-prefix-as-path count;
destination-prefix-as-path count;
bgp-source-standard-community count;
bgp-destination-standard-community count;
bgp-source-extended-community count;
bgp-destination-extended-community count;
... | [edit services flow-monitoring version-ipfix template template-name] | Use this configuration statement to add Information Elements to an IPFIX or a version 9 data record
template. Any new or changed configuration of this statement is effective immediately and the exported
packets contain the new information. Each Information Element is independent of the others and can be
exported separa... | [
{
"name": "include-policy-map-name",
"desc": "Export the Juniper-specific enterprise Information Element ID 32765 in the data record templates ip4-template and ipv6-template. This new IE ID is 4 bytes long and contains the first 4 characters of the policy-map name. Therefore, the first 4 letters of your pol... | system—To view this statement in the configuration.
system-control—To add this statement to the configuration. | Statement introduced in Junos OS Evolved Release 21.4R1.
Option include-policy-map-name introduced in Junos OS Evolved 24.4R1. | [
"Assigning Rewrite Rules on a Per-Customer Basis Using Policy Maps"
] |
data-size | data-size size; | [edit services monitoring rpm owner name test name] | Specify the size of the data portion of ICMP probes. The data-size statement is not valid with the http-get
or http-metadata-get probe type. | [
{
"name": "size",
"desc": "0 through 65400 for RPM, for TWAMP the value is from 60 through 1400."
}
] | system—To view this statement in the configuration.
system-control—To add this statement to the configuration. | Statement introduced before Junos OS Release 7.4.
Statement introduced in Junos OS Release 9.3 for EX Series switches.
Statement introduced in Junos OS Release 13.2 for PTX Series Packet Transport routers.
Support at the [edit services rpm twamp client control-connection control-client-name] hierarchy level
introduced ... | [
"Understanding Using Probes for Real-Time Performance Monitoring on M, T, PTX, and MX Series",
"Routers",
"Configuring BGP Neighbor Discovery Through RPM"
] |
data-tlv-size | data-tlv-size size; | [edit protocols oam ethernet connectivity-fault-management maintenance-domain md-name maintenance-
association ma-name mep mep-id remote-mep remote-mep-id sla-iterator-profile profile-name] | Configure the size of the data TLV portion of the Y.1731 data frame. | [
{
"name": "size",
"desc": "Size of the data TLV portion of the Y.1731 data frame."
}
] | Configure—To enter configuration mode.
Control—To modify any configuration. | Statement introduced in Junos OS Release 11.1. | [
"Configuring a Remote MEP with an Iterator Profile"
] |
database | database {
export;
import;
} | [edit logical-systems logical-system-name protocols mpls traffic-engineering],
[edit protocols mpls traffic-engineering] | Include link and node entries from the traffic engineering database into the lsdist.0 routing information
base (RIB), so it gets picked up by the BGP export policy.
The remaining statements are explained separately. See CLI Explorer. | [] | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 14.2. | [] |
database-protection | database-protection {
ignore-count number;
ignore-time seconds;
maximum-lsa number;
reset-time seconds;
warning-only;
warning-threshold percent;
} | [edit protocols (ospf | ospf3)],
[edit logical-systems logical-system-name routing-instances routing-instance-name protocols
(ospf | ospf3)],
[edit routing-instances routing-instance-name protocols (ospf | ospf3)],
[edit routing-instances routing-instance-name protocols ospf3 realm (ipv4-unicast | ipv4-
multicast | ip... | Configure the maximum number of link-state advertisements (LSAs) that are not generated by the router
or switch in a given OSPF instance.
Default
By default, OSPF database protection is not enabled. | [
{
"name": "ignore-count number",
"desc": "Configure the number of times the database can enter the ignore state. When"
},
{
"name": "ignore-time seconds",
"desc": "Configure the time the database must remain in the ignore state before it resumes"
},
{
"name": "maximum-lsa number",
"d... | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 10.2. | [
"OSPF Database Protection Overview",
"Configuring OSPF Database Protection"
] |
database-replication (Subscriber Session Database) | database-replication {
traceoptions {
file filename <files number> <match regular-expression > <size maximum-file-size> <world-
readable | no-world-readable>;
flag flag;
}
} | [edit system services] | CAUTION: Enabling tracing can adversely impact scale and performance and may
increase security risk. We strongly recommend using the trace, tracing, or traceoptions
commands only under the guidance of a JTAC support engineer. After collecting the
debug information, immediately disable tracing to minimize risk and resto... | [] | system—To view this statement in the configuration.
system-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 9.3. | [
"Tracing Subscriber Management Session Database Replication Events for Troubleshooting"
] |
datapath-debug | datapath-debug {
action-profile name {
event name {
count;
packet-dump;
packet-summary;
trace;
}
module name {
flag name;
}
preserve-trace-order;
record-pic-history;
}
capture-file (Security) filename... | [edit security] | CAUTION: Enabling tracing can adversely impact scale and performance and may
increase security risk. We strongly recommend using the trace, tracing, or traceoptions
commands only under the guidance of a JTAC support engineer. After collecting the
debug information, immediately disable tracing to minimize risk and resto... | [] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Command introduced in Junos OS Release 10.0. | [
"Understanding Data Path Debugging for Logical Systems"
] |
dcbx | dcbx {
disable;
interface (interface-name | all) {
disable;
application-map application-map-name;
applications {
no-auto-negotiation;
}
enhanced-transmission-selection {
no-auto-negotiation;
no-recommendation-tlv;
recommend... | [edit protocols] | Configure DCBX properties. DCBX is an extension of Link Layer Discovery Protocol (LLDP), and LLDP
must remain enabled on every interface for which you want to use DCBX. If you attempt to enable
DCBX on an interface on which LLDP is disabled, the configuration commit fails. | [] | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 11.1.
mode and recommendation-tlv statements introduced in Junos OS Release 12.2 for the QFX Series. | [
"Understanding DCB Features and Requirements",
"Configuring DCBX Autonegotiation"
] |
dcbx-version | dcbx-version (auto-negotiate | ieee-dcbx | dcbx-version-1.01); | [edit protocols dcbx interface (all | interface-name)] | Set the DCBX version for the specified interface or interfaces.
QFX3500 switches come up in IEEE DCBX mode and then autonegotiate with the connected peer to
set the DCBX version.
QFabric system Node devices come up using DCBX version 1.01, and then autonegotiate with the
connected peer to set the DCBX mode.
Default
Th... | [
{
"name": "auto-negotiate",
"desc": "Automatically negotiate the DCBX version with the connected peer."
},
{
"name": "ieee-dcbx",
"desc": "Force the interface to use IEEE DCBX mode, regardless of the peer configuration."
},
{
"name": "dcbx-version-1.01",
"desc": "Force the interface ... | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 12.2. | [
"Configuring DCBX Autonegotiation",
"Understanding DCBX"
] |
dcd | dcd (ignore | normal | require); | [edit interfaces interface-name serial-options dce-options],
[edit interfaces interface-name serial-options dte-options] | For EIA-530 and V.35 interfaces only, configure the from-DCE signal, data-carrier-detect (DCD). | [
{
"name": "ignore",
"desc": "The from-DCE signal is ignored."
},
{
"name": "normal",
"desc": "Normal DCD signal handling as defined by the TIA/EIA Standard 530."
},
{
"name": "require",
"desc": "The from-DCE signal must be asserted."
}
] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced before Junos OS Release 7.4. | [
"Configuring the Serial Signal Handling"
] |
dcd-polarity | dcd-polarity (negative | positive); | [edit interfaces interface-name serial-options] | Configure DCD signal polarity. | [
{
"name": "positive",
"desc": "Positive signal polarity."
},
{
"name": "negative",
"desc": "Negative signal polarity."
}
] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced before Junos OS Release 7.4. | [
"Configuring Serial Signal Polarities"
] |
dce-options | dce-options {
control-signal (assert | de-assert | normal);
cts (ignore | normal | require);
dcd (ignore | normal | require);
dsr (ignore | normal | require);
dtr signal-handling-option;
ignore-all;
indication (ignore | normal | require);
rts (assert | de-assert | normal);
tm (ignor... | [edit interfaces interface-name serial-options] | For J Series Services Routers, configure the serial interface signal characteristics.
The remaining statements are explained separately. See CLI Explorer. | [] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 8.3.
Statement previously known as control-leads. | [
"Configuring the Serial Signal Handling"
] |
ddos-protection (DDoS) | ddos-protection
global {
disable-fpc;
disable-logging;
disable-routing-engine;
flow-detection;
flow-level-control;
flow-detection-mode;
flow-report-rate;
violation-report-rate;
}
protocols protocol-group (aggregate | packet-type) {
ban... | [edit system] | CAUTION: Enabling tracing can adversely impact scale and performance and may
increase security risk. We strongly recommend using the trace, tracing, or traceoptions
commands only under the guidance of a JTAC support engineer. After collecting the
debug information, immediately disable tracing to minimize risk and resto... | [] | admin—To view this statement in the configuration.
admin-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 11.2.
Support for Enhanced Subscriber Management added in Junos OS Release 17.3R1.
Statement introduced in Junos OS Release 24.2R1 for MX304 devices. | [
"Control Plane Distributed Denial-of-Service (DDoS) Protection Overview",
"Configuring Control Plane DDoS Protection"
] |
ddos-protection | ddos-protection {
global {
disable-fpc;
disable-logging;
disable-routing-engine;
flow-detection;
flow-detection-mode(automatic | off | on);
flow-level-control(drop | keep | police);
flow-report-rate reports per second;
violation-report-rate reports per second;
}
protocols {
all-fiber-channel-enode ... | [edit system] | CAUTION: Enabling tracing can adversely impact scale and performance and may
increase security risk. We strongly recommend using the trace, tracing, or traceoptions
commands only under the guidance of a JTAC support engineer. After collecting the
debug information, immediately disable tracing to minimize risk and resto... | [] | admin—To view this statement in the configuration.
admin-control—To add this statement to the configuration.
Release Information | [] | |
deactivate | deactivate (statement | identifier) | Add the inactive: tag to a statement, effectively commenting out the statement or identifier from the
configuration. Statements or identifiers marked as inactive do not take effect when you issue the commit
command. | [
{
"name": "identifier",
"desc": "Identifier to which you are adding the inactive: tag. It must be an identifier at the current hierarchy level."
},
{
"name": "statement",
"desc": "Statement to which you are adding the inactive: tag. It must be a statement at the current hierarchy level."
}
] | configure—To enter configuration mode, but other required privilege levels depend on where the
statement is located in the configuration hierarchy. | Command introduced before Junos OS Release 7.4. | [
"Deactivating and Reactivating Statements and Identifiers in a Device Configuration"
] | |
deactivation-attribute (AAA Profile) | deactivation-attribute {
<code numeric-code;>
<vendor-id vendor-id;>
} | [edit unified-edge aaa profiles aaa-profile-name radius policy] | Configure the RADIUS attribute that you want to carry the PCC rulebase name for rulebase
deactivations from the RADIUS policy server to the MX Series router. By default, the rulebase name is
carried in the ERX-Service-Deactivate Juniper vendor-specific attribute.
The remaining statements are explained separately. See C... | [] | unified-edge—To view this statement in the configuration.
unified-edge-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 17.1. | [
"Configuring an AAA Profile",
"Understanding AAA Profiles",
"Understanding How a RADIUS Server Controls Policy and Charging Control Rules"
] |
deactivation-delay | deactivation-delay seconds; | [edit interfaces dln unit logical-unit-number dialer-options] | On J Series Services Routers with ISDN interfaces, configure the ISDN deactivation delay. Used only for
dialer backup and dialer watch cases. | [
{
"name": "seconds",
"desc": "Interval before the backup interface is deactivated after the primary interface has comes up."
}
] | interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration. | Statement introduced before Junos OS Release 7.4. | [] |
dead-criteria-retries (RADIUS Server) | dead-criteria-retries retry-number interval seconds; | [edit access radius servers name] | Configure a limit to the number of times the MX Series router can resend a request to the RADIUS
server when no response from the RADIUS server is received. If the number of retries reaches this limit,
the RADIUS server is marked as dead, and the MX Series router begins to send requests to other
RADIUS servers in the n... | [
{
"name": "retry-number",
"desc": "Number of retries. Range: 10 through 65535"
},
{
"name": "seconds",
"desc": "Time interval in seconds. Range: 5 through 300"
}
] | access—To view this statement in the configuration.
access-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 17.1. | [
"Configuring RADIUS Servers",
"Understanding Network Elements",
"Understanding How a RADIUS Server Controls Policy and Charging Control Rules"
] |
dead-peer-detection (Security Group VPN Server) | dead-peer-detection {
always-send;
interval seconds;
threshold number;
} | [edit security group-vpn server ike gateway gateway-name] | Enable the device to use dead peer detection (DPD). DPD is a method used by devices to verify the
current existence and availability of IPsec peers. A device performs this verification by sending
encrypted IKE Phase 1 notification payloads (R-U-THERE messages) to a peer and waiting for DPD
acknowledgements (R-U-THERE-A... | [
{
"name": "always-send",
"desc": "Send probes periodically regardless of incoming and outgoing data traffic. Starting in Junos"
},
{
"name": "interval seconds",
"desc": "Specify the interval time in seconds between DPD probe messages."
},
{
"name": "threshold number",
"desc": "Specif... | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Support for the Group VPN server added in Junos OS Release 15.1X49-D30 for vSRX Virtual Firewall. | [
"Group VPNv2 Overview"
] |
dead-peer-detection (Services IPsec VPN) | dead-peer-detection {
interval seconds;
threshold number;
} | [edit services ipsec-vpn rule-name term term-name then] | Sets dead peer detection options when dead peer detection has been enabled with the initiate-dead-
peer-detection command. The dead-peer-detection options are used for IKEv1 security associations (SAs).
Starting in Junos OS Release 17.2R1, the dead-peer-detection options are also applicable to IKEv2 SAs. In
Junos OS Re... | [
{
"name": "interval",
"desc": "Specify the amount of time that the peer waits for dead-peer-detection (DPD) response"
},
{
"name": "threshold",
"desc": "Specify the maximum number of unsuccessful dead peer detection (DPD) requests to be"
}
] | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 11.4.
IKEv2 support introduced in Junos OS Release 17.2. | [] |
dead-peer-detection | dead-peer-detection {
(always-send | optimized | probe-idle-tunnel);
interval seconds;
threshold number;
} | [edit security ike gateway gateway-name] | Enable the device to use dead peer detection (DPD). DPD is a method used by devices to verify the
current existence and availability of IPsec peers. A device performs this verification by sending
encrypted IKE Phase 1 notification payloads (R-U-THERE messages) to a peer and waiting for DPD
acknowledgements (R-U-THERE-A... | [
{
"name": "interval",
"desc": "Specify the amount of time that the peer waits for traffic from its destination peer before sending a dead-peer-detection (DPD) request packet. Default: 10 seconds Range: 2 through 60 seconds"
},
{
"name": "always-send",
"desc": "Instructs the device to send dead... | security—To view this statement in the configuration.
security-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 8.5. Support for the optimized and probe-idle-tunnel options
added in Junos OS Release 12.1X46-D10.
Support for multiple peer addresses in DPD configuration with IPsec VPN running iked process is
introduced in Junos OS Release 23.4R1. | [
"Understanding AutoVPN",
"IPsec VPN Overview"
] |
deaggregate | deaggregate | no-deaggregate; | [edit logical-systems logical-system-name protocols ldp],
[edit logical-systems logical-system-name routing-instances routing-instance-name protocols ldp],
[edit protocols ldp],
[edit routing-instances routing-instance-name protocols ldp] | Control forwarding equivalence class (FEC) deaggregation on the router. The use of the deaggregate
statement in LDP is a standard practice that we recommend for LDP deployments.
Default
Deaggregation is disabled on the router. | [
{
"name": "deaggregate",
"desc": "Deaggregate FECs."
},
{
"name": "no-deaggregate",
"desc": "Aggregate FECs."
}
] | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced before Junos OS Release 7.4. | [
"Configuring FEC Deaggregation"
] |
debounce-interval | debounce-interval seconds; | [edit logical-systems name protocols uplink-failure-detection group],
[edit protocols uplink-failure-detection group] | The amount of time, in seconds, that elapses before the downlink interfaces are brought up after a state
change of the uplink interfaces. | [
{
"name": "seconds",
"desc": "Delay, in seconds, before bringing up the link-to-disable port."
}
] | admin—To view this statement in the configuration.
admin-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 19.2R1. | [] |
debug-level (System Services) | debug-level (alert | crit | emerg | error | info | notice | warn); | [edit system services webapi (System Services)] | Specify the trace level for the integrated ClearPass authentication and enforcement Web API process
(webapi). Level describes a flag that specifies the type of logs to be write into the log file for the Web
API process (webapi). | [
{
"name": "debug-level",
"desc": "Debug level for webapi process. Values:"
},
{
"name": "alert",
"desc": "Matches alert messages."
},
{
"name": "crit",
"desc": "Matches critical messages."
},
{
"name": "emerg",
"desc": "Matches emergency messages."
},
{
"name": "... | 1. system—To view this statement in the configuration.
2. system-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 12.3X48-D30. | [] |
debug-log (System Services) | debug-log file; | [edit system services webapi (System Services)] | Specify the name of the log file to which trace messages for the integrated ClearPass authentication and
enforcement Web API process (webapi) are written.
The debug level flag determines the kind of logs that are written to this file. | [
{
"name": "file",
"desc": "Debug file for Web API process."
}
] | 1. system—To view this statement in the configuration.
2. system-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 12.3X48-D30. | [] |
decapsulate (Firewall Filter) | decapsulate {
gre {
apply-groups;
apply-groups-except;
forwarding-class;
interface-group(0 -255)
no-decrement-ttl;
routing-instance;
sample;
}
inet-in-udp {
apply-groups;
apply-groups-except;
forwarding-class;
no-decreme... | [edit firewall family family-name filter filter-name term term-name then] | Define the termination action for GRE, UDP, and L2TP tunnels.
NOTE: inet-in-udp, inet6-in-udp, and mpls-in-udp are supported only on PTX10003,
PTX10004, PTX10008, PTX10016 and PTX10001-36MR device models.
Caveats
The following are the caveats for using the decapsulate firewall filter action.
•
For GRE tunnel decapsulat... | [
{
"name": "gre",
"desc": "(Optional) Terminate a GRE tunnel for the filter conditions that are matched."
},
{
"name": "inet-in-udp",
"desc": "(Optional) Terminate a UDP tunnel with IPv4 payload."
},
{
"name": "inet6-in-udp",
"desc": "(Optional) Terminate a UDP tunnel with IPv6 payloa... | firewall—To view this statement in the configuration.
firewall-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 7.6.
output-interface and cookie options introduced in Junos OS Release 15.1.
decapsulate gre introduced in Junos OS Release 15.1F3 and 16.1R2 for PTX5000 routers with third
generation FPCs and Junos OS Release 15.1F6 and 16.1R2 for PTX3000 routers with third-generation
FPCs.
n... | [
"Guidelines for Configuring Firewall Filters",
"Configuring Multifield Classifiers",
"Guidelines for Configuring and Applying Firewall Filters in Logical Systems"
] |
decapsulate-accept-inner-vlan | decapsulate-accept-inner-vlan | [edit protocols l2-learning]
[edit routing-instances routing-instance-name vlans vlan-name vxlan] | Configure the switch to de-encapsulate and to accept original VLAN tags in Virtual Extensible LAN
(VXLAN) packets.
We require this option on some platforms to process tagged VXLAN payloads so the device doesn't drop
the tagged packet. You don't need to configure this option in some use cases, such as:
•
On the QFX10000... | [] | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement modified in Junos OS Release 14.1X53 for the QFX Series. | [
"Understanding VXLANs",
"Examples: Tunneling Q-in-Q Traffic in an EVPN-VXLAN Overlay Network"
] |
decapsulate-inner-vlan | decapsulate-inner-vlan | [edit routing-instances routing-instance-name vlans vlan-name vxlan],
[edit vlans vlan-name vxlan] | Configure the switch to de-encapsulate a preserved original VLAN tag (in the inner Ethernet packet)
from a VXLAN encapsulated packet.
Default
A preserved VLAN tag is dropped when the packet is de-encapsulated. | [] | routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration. | Statement introduced in Junos OS Release 14.1X53-D10. | [
"Understanding VXLANs",
"Manually Configuring VXLANs on QFX Series and EX4600 Switches",
"Examples: Manually Configuring VXLANs on QFX Series and EX4600 Switches"
] |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.