command stringlengths 2 75 | syntax stringlengths 0 289k | hierarchy_level stringlengths 0 6.91k | description stringlengths 0 45.2k | options listlengths 0 499 | required_privilege_level stringlengths 0 330k | release_information stringlengths 0 3.14k | related_documentation listlengths 0 22 |
|---|---|---|---|---|---|---|---|
show chassis fabric fpcs | show chassis fabric fpcs
<extended>
<slot fpc-slot> | Display the state of the electrical switch fabric links between the Flexible PIC Concentrators (FPCs) and
the Switch Interface Boards (SIBs). (PTX10002-36QDD devices only) Display peer FPC / Packet
Forwarding Engine (PFE) details because the PFEs are directly connected to each other. | [
{
"name": "none",
"desc": "Display the switch fabric link state."
},
{
"name": "extended",
"desc": "(Optional) Display the fabric link state for all fabric planes."
},
{
"name": "all-members",
"desc": "(MX Series routers only) (Optional) Display the switching fabric link states for t... | view
Output Fields
Table 292 on page 18907 lists the output fields for the show chassis fabric fpcs command. Output fields
are listed in the approximate order in which they appear.
Table 292: show chassis fabric fpcs Output Fields
Field Name
Field Description
Fabric management FPC state
Switching fabric link (link fro... | Command introduced before Junos OS Release 7.4.
extended option introduced in JunosOS Release 16.1. | [
"Displaying Information About DPCs or FPCs in an MX Series Router"
] | |
show chassis fabric map | show chassis fabric map
<all-members>
<local>
<member member-id>
<plane plane-number> | (M120 and MX Series routers and EX8200 switches only) On the M120 router, display the state of the
switching fabric map for connections from the Forwarding Engine Boards (FEBs) to the ports on the
fabric planes, as interpreted by the fabric plane. On the MX Series router and the EX8200 switch,
display the state of the ... | [
{
"name": "none",
"desc": "Display the switching fabric map state for the M120 or MX Series router or EX8200 switch."
},
{
"name": "all-members",
"desc": "(MX Series routers only) (Optional) Display the switching fabric map state for all the members of the Virtual Chassis configuration."
},
... | view
Output Fields
Table 293 on page 18920 lists the output fields for the show chassis fabric map command. Output fields
are listed in the approximate order in which they appear.
Table 293: show chassis fabric map Output Fields
Field Name
Field Description
in-links
Fabric map for receive side links.
out-links
Fabric ... | Command introduced in Junos OS Release 8.0. | [] | |
show chassis fabric mesh | show chassis fabric mesh < feb | topology > | (M120 router only) Display the state of the electrical and optical switching fabric links between the
Forwarding Engine Boards (FEBs) and the fabric planes, as interpreted by the FEB. | [] | view
Output Fields
Table 294: show chassis fabric mesh feb Output Fields
Field Name
Field Description
Fabric management FEB state
State of the switching fabric mesh between each FEB and fabric plane:
desalination error, disabled, enabled, link error, link ok, or unused.
Table 295: show chassis fabric mesh topology Outp... | Command introduced in Junos OS Release 21.3 | [] | |
show chassis fabric plane (Security) | show chassis fabric plane | Show state of fabric management plane. | [] | view
Output Fields
Table 296 on page 18931 lists the output fields for the show chassis fabric plane command. Output
fields are listed in the approximate order in which they appear.
Table 296: show chassis fabric plane Output Fields
Field Name
Field Description
Level of output
Plane
Number of the plane.
none
Table 296... | Command introduced in Junos OS Release 9.2. | [] | |
show chassis fabric plane | show chassis fabric plane
<extended>
<detail | extensive | terse>
<all-members>
<local>
<member member-id> | (TX Matrix Plus router, T4000, T1600, M120, and MX Series routers and EX8200 switches only) On the
M120 router, display the state of all fabric plane connections to the Forwarding Engine Boards (FEBs).
On MX Series routers, display the state of all fabric plane connections to the Dense Port Concentrators
(DPCs) and Pac... | [
{
"name": "none",
"desc": "(MX2010, MX2020, and MX2008 Routers only) (Optional) Display the state of the fabric management plane."
},
{
"name": "extended",
"desc": "(MX2020, MX2010, and MX2008 Routers only) (Optional) Display the state of the fabric management planes (all 24 fabric planes)."
}... | view
Output Fields
Table 297 on page 18942 lists the output fields for the show chassis fabric plane command. Output fields
are listed in the approximate order in which they appear.
Table 297: show chassis fabric plane Output Fields
Field Name
Field Description
Level of output
Plane
(TX Matrix Plus, MX Series routers, ... | Command introduced in Junos OS Release 8.0.
detail, extensive, lcc, sfc, and terse options introduced for the TX Matrix Plus router in Junos OS Release
9.6.
extended option introduced in Junos OS Release 16.1 for MX2020 and MX2010 Routers. | [
"Routing Matrix with a TX Matrix Plus Router Solutions Page"
] | |
show chassis fabric plane-location (Security) | show chassis fabric plane-location | Show fabric plane location. | [] | view
Output Fields
Table 298 on page 18981 lists the output fields for the show chassis fabric plane-location command.
Output fields are listed in the approximate order in which they appear.
Table 298: show chassis fabric plane-location Output Fields
Field Name
Field Description
Plane n
Plane number.
Control Board n
Co... | Command introduced in Junos OS Release 9.2. | [] | |
show chassis fabric plane-location | show chassis fabric plane-location
<extended> | (M120, MX Series routers, and EX8200 switches only) Display the Control Board (CB) location of each
plane. This command can be used on the primary Routing Engine or the backup Routing Engine. For
information about the meaning of “CBs” and “fabric plane” on the switches, see the hardware
documentation for your switch.
(... | [
{
"name": "all-members",
"desc": "(MX Series routers only) (Optional) Display the CB location of each fabric plane on the Routing Engines in all member routers in the Virtual Chassis configuration."
},
{
"name": "local",
"desc": "(MX Series routers only) (Optional) Display the CB location of eac... | view
Output Fields
Table 299 on page 18984 lists the output fields for the show chassis fabric plane-location command.
Output fields are listed in the approximate order in which they appear.
Table 299: show chassis fabric plane-location Output Fields
Field Name
Field Description
Plane n
Plane number.
(PTX Series Packet... | Command introduced in Junos OS Release 8.0.
extended option introduced in Junos OS Release 16.1R1 for MX2020 and MX2010 Universal Routing
Platforms. | [] | |
show chassis fabric reachability | show chassis fabric reachability
<detail>
<extended> | (M320, MX240, MX480, MX960, PTX Series, and T Series routers only) Display the current state of
fabric destination reachability. Additionally, display the details of the automated actions taken by the
system to stop null-route filtering and attempt healing, and the final resolution of the actions. | [
{
"name": "none",
"desc": "Display the state of fabric destination reachability for M320, MX240, MX480, MX960, PTX Series, T640, T1600, and TX Matrix routers, based on periodic reachability checks. Display the system's action phase sequences to stop the null route and attempt healing, and the final resoluti... | view
Output Fields
The table lists the output fields for the show chassis fabric reachability command. Output fields are listed
in the approximate order in which they appear.
Table 300: show chassis fabric reachability Output Fields
Field Name
Field Description
Level of
Output
Fabric reachability
status
Display the re... | Command introduced before Junos OS Release 11.4.
extended option introduced in Junos OS Release 16.1R1 for MX2010 and MX2020 Universal Routing
Platforms. | [] | |
show chassis fabric redundancy-mode | show chassis fabric redundancy-mode | (MX240, MX480, and MX960 routers only) Display whether redundancy mode is configured for active
control boards to enable increased fabric bandwidth usage. | [] | view
Output Fields
Table 301 on page 19008 lists the output fields for the show chassis fabric redundancy-mode command.
Output fields are listed in the approximate order in which they appear.
Table 301: show chassis fabric redundancy mode Output Fields
Field name
Field Description
Fabric redundancy
mode
Currently confi... | Command introduced in Junos OS Release 12.2. | [
"Detection and Corrective Actions of Line Cards with Degraded Fabric on MX Series Routers",
"Detection and Recovery of Fabric-Related Failures Caused by Loss of Connectivity on MX Series",
"Routers",
"MX Series Routers Fabric Resiliency",
"Configuring Fabric Redundancy Mode for Active Control Boards on MX S... | |
show chassis fabric sibs | show chassis fabric sibs
<extended>
<slot slot-number> | (M320, PTX Series routers and QFX Series switches) Display the state of the electrical switch fabric link
between the SIBs and the FPCs. | [
{
"name": "none",
"desc": "(M320 PTX Series routers and QFX Series switches) Display the state of the electrical switch fabric link between the SIBs and the FPCs."
},
{
"name": "extended",
"desc": ""
},
{
"name": "(Optional) Show all planes in output",
"desc": ""
},
{
"name":... | view
Output Fields
Table 302 on page 19010 lists the output fields for the show chassis fabric sibs command. Output fields
are listed in the approximate order in which they appear.
Table 302: show chassis fabric sibs Output Fields
Field Name
Field Description
Fabric management SIB state
Switching fabric link (link from... | Command introduced before Junos OS Release 7.4.
Command introduced on QFX Series switches in Junos OS Release 15.1X53-D30 | [
"Monitoring the SIBs",
"Redundant SIBs Overview"
] | |
show chassis fabric stream-info | show chassis fabric stream-info | Display the fabric stream information.
Additional Information
This command provides the fabric stream numbering for all PFEs across all FPC slots in the chassis. The
number of PFEs depends on the line card in the chassis. | [] | view
Output Fields
Table 303 on page 19020 lists the output fields for the show chassis fabric stream-info command.
The output is displayed independent of the line card and status of the FPC or PFE. The output is based
on the chassis and the fabric card. Output displays the maximum PFEs defined for that chassis (for
e... | Command introduced in Junos OS Release 21.4R1. | [] | |
show chassis fabric summary (Security) | show chassis fabric summary | Show summary fabric management state. | [] | view
Output Fields
Table 304 on page 19026 lists the output fields for the show chassis fabric summary command. Output
fields are listed in the approximate order in which they appear.
Table 304: show chassis fabric summary Output Fields
Field Name
Field Description
Plane
Plane number.
State
State of the SIB or FPC:
•
... | Command introduced in Junos OS Release 9.2. | [] | |
show chassis fabric summary | show chassis fabric summary <extended> | (MX Series routers and EX8200 switches only) Display the state of all fabric planes and the elapsed
uptime.
(QFX Series devices) Display the state of all fabric planes.
(PTX Series devices) Display the state of all fabric planes. Each fabric chip hosts a single plane in
PTX10016. PTX10008 hosts 2 planes per fabric chip... | [
{
"name": "extended",
"desc": "(Optional) Display the extended summary of fabric planes. PTX Series devices do not support"
}
] | view
Output Fields
Table 305 on page 19029 lists the output fields for the show chassis fabric summary command. Output
fields are listed in the approximate order in which they appear.
Table 305: show chassis fabric summary Output Fields
Field Name
Field Description
Plane
(MX Series, MX2020, MX2010, and MX2008 Routers o... | Command introduced in Junos OS Release 8.4.
extended option added in Junos OS Release 14.1R2. | [] | |
show chassis fabric topology | show chassis fabric topology | (TX Matrix routers only) Display the state of the switching fabric topology for the Switch Interface Board
(SIB) connection between the TX Matrix router and the T640 routers.
(TX Matrix Plus routers only) Display the state of the switching fabric topology for the SIB connection
between the TX Matrix Plus router and the... | [
{
"name": "none",
"desc": "(TX Matrix routers only) Display the state of the switching fabric topology for the Switch Interface Board (SIB) connection between the TX Matrix router and the T640 routers. (TX Matrix Plus routers only) Display the state of the switching fabric topology for the SIB connection be... | view
Output Fields
Table 306 on page 19038 lists the output fields for the show chassis fabric topology command. Output
fields are listed in the approximate order in which they appear.
Table 306: show chassis fabric topology Output Fields
Field Name
Field Description
in-links
Fabric topology for receive side links.
out... | Command introduced before Junos OS Release 7.4.
sfc option introduced for the TX Matrix Plus router in Junos OS Release 9.6. | [
"Layer 2 Wholesale Network Topology Overview"
] | |
show chassis fabric unreachable-destinations | show chassis fabric unreachable-destinations | (M320 and T Series routers only) Display the list of destinations that have transitioned from a reachable
state to an unreachable state. | [] | view
Output Fields
The table lists the output fields for the show chassis fabric unreachable-destinations command. Output fields
are listed in the approximate order in which they appear.
Table 307: show chassis fabric unreachable-destinations Output Fields
Field Name
Field Description
Flexible PIC Concentrator (FPC)
n... | Command introduced before Junos OS Release 11.4. | [] | |
show chassis fan | show chassis fan
<lcc number | sfc number> | (T Series routers, TX Matrix routers, TX Matrix Plus routers, M120 routers, M320 routers, MX104
routers, MX2010 routers, MX2020 routers, MX2008 routers, MX Series 5G Universal Routing Platforms,
QFX3008-I Interconnect devices, QFX Series, OCX Series, EX Series switches, and PTX Series Packet
Transport Routers only) Sho... | [
{
"name": "all-members",
"desc": "(MX Series routers only) (Optional) Display information about the fan tray and fans for all members of the Virtual Chassis configuration."
},
{
"name": "local",
"desc": "(MX Series routers only) (Optional) Display information about the fan tray and fans for the ... | view
Output Fields
Table 308 on page 19079 lists the output fields for the show chassis fan command. Output fields are listed
in the approximate order in which they appear.
Table 308: show chassis fan Output Fields
Field Name
Field Description
Item
Fan item identifier.
Table 308: show chassis fan Output Fields (Contin... | Command introduced in Junos OS Release 10.0 on MX Series 5G Universal Routing Platforms, M120
routers, and M320 routers, T320 routers, T640 routers, T1600 routers, TX Matrix Routers, and TX
Matrix Plus routers.
satellite option introduced in Junos OS Release 14.2R3.
Command output introduced for Junos OS Evolved Releas... | [] | |
show chassis feb | show chassis feb | (ACX1000, ACX7509 and QFX5700 devices only) Display Forwarding Engine Board (FEB) status
information. Use this command to identify the memory allocated for each PFE (Packet Forwarding
Engine). | [] | view
Output Fields
Table 309 on page 19096 lists the output fields for the show chassis feb command. Output fields are listed
in the approximate order in which they appear.
Table 309: show chassis feb
Field Name
Field Description
State
State of the FEB:
•
Offline—FEB is powered down.
•
Online—FEB is operational and ru... | Command introduced before Junos OS Release 7.4.
Command support added for ACX7509 platform in Junos OS Evolved Release 22.2. Detail option is not
supported on ACX7509 platform. | [
"Understanding Switching Control Board Redundancy"
] | |
show chassis firmware | show chassis firmware
<detail>
<satellite [slot-id slot-id |device-alias alias-name]> | On routers and switches, display the version levels of the firmware running on the System Control Board
(SCB), Switching and Forwarding Module (SFM), System and Switch Board (SSB), Forwarding Engine
Board (FEB), Flexible PIC Concentrators (FPCs), and Routing Engines. On a TX Matrix Plus router, display
the version leve... | [
{
"name": "none",
"desc": "Display the version levels of the firmware running. For an EX4200 switch that is a member of a Virtual Chassis, display version levels for all members. For a TX Matrix router, display version levels for the firmware on the TX Matrix router and on all the T640 routers connected to ... | view
Output Fields
Table 310 on page 19103 lists the output fields for the show chassis firmware command. Output fields
are listed in the approximate order in which they appear.
Table 310: show chassis firmware Output Fields
Field Name
Field Description
Part
(MX Series, MX2010, MX2020, and MX2008 routers) Chassis part ... | Command introduced before Junos OS Release 7.4.
sfc option introduced in Junos OS Release 9.6 for the TX Matrix Plus router.
Command introduced for EX8200 switches in Junos OS Release 10.2 for EX Series switches.
satellite option introduced in Junos OS Release 14.2R3. | [] | |
show chassis forwarding | show chassis forwarding | Display status of the forwarding process (fwdd). This command is supported on Branch SRX Series
Firewalls. | [] | view
Output Fields
Table 311 on page 19121 lists the output fields for the show chassis forwarding command. Output fields
are listed in the approximate order in which they appear.
Table 311: show chassis forwarding Output Fields
Field Name
Field Description
FWWD status
Forwarding status:
•
State:
•
Online—FWDD is opera... | Current—Command introduced before Junos OS Release 7.4.
Now—Command introduced in Junos OS Release 7.4. Support for Branch SRX Series added in Junos OS
Release 10.1 | [] | |
show chassis forwarding-options | show chassis forwarding-options | Display the configuration for the Unified Forwarding Table. | [] | view
Output Fields
Table 312 on page 19124 lists the output fields for the show chassis forwarding-options command. Output
fields are listed in the approximate order in which they appear.
Table 312: show chassis forwarding-options Output Fields
Field Name
Field Description
profile name
Name of profile configured:
•
cu... | Command introduced in Junos OS Release 13.2
Support added to QFX5200 switches in Junos OS Release 15.1X53-D30 | [
"Configuring the Unified Forwarding Table on Switches",
"Example: Configuring a Unified Forwarding Table Custom Profile"
] | |
show chassis fpc (GNF) | show chassis fpc | Display information about the Flexible PIC Concentrators (fpcs) assigned to the guest network function
(GNF). | [] | view
Output Fields
Table 313 on page 19128 lists the output fields for the show chassis fpc command. Output fields are listed
in the approximate order in which they appear.
Table 313: show chassis fpc Output Fields
Field Name
Field Description
Slot or Slot State
Slot number and state. The state can be one of the follo... | Command introduced before Junos OS Release 7.4. | [] | |
show chassis fpc (Node Slicing) | show chassis fpc | Display information about Flexible PIC Concentrators (fpcs) assigned to different guest network
functions (GNFs). | [] | view
Output Fields
Table 314 on page 19131 lists the output fields for the show chassis fpc command. Output fields are listed
in the approximate order in which they appear.
Table 314: show chassis fpc Output Fields
Field Name
Field Description
Slot or Slot State
Slot number and state. The state can be one of the follo... | Command introduced before Junos OS Release 7.4. | [] | |
show chassis fpc (View) | show chassis fpc
<detail < fpc-slot >| <node ( node-id | local | primary)>> |
<node ( node-id | local | primary)> |
<pic-status < fpc-slot >| <node ( node-id | local | primary)>> | Display status information about the installed Flexible PIC Concentrators (FPCs) and PICs. | [
{
"name": "none",
"desc": "Display status information for all FPCs."
},
{
"name": "detail",
"desc": "(Optional) Display detailed FPC status information."
},
{
"name": "fpc-slot",
"desc": "(Optional) Display information about the FPC in this slot."
},
{
"name": "node",
"de... | view
Output Fields
Table 315 on page 19135 lists the output fields for the show chassis fpc command. Output fields are
listed in the approximate order in which they appear.
Table 315: show chassis fpc Output Fields
Field Name
Field Description
Slot or Slot State
Slot number and state. The state can be one of the follo... | Command modified in Junos OS Release 9.2.
Starting with Junos OS Release 15.1X49-D10 and Junos OS Release 17.3R1, the SRX5K-
MPC3-100G10G (IOC3) and the SRX5K-MPC3-40G10G (IOC3) are introduced.
NOTE: On SRX5K-MPC3-40G10G (IOC3), all four PICs cannot be powered on. A
maximum of two PICs can be powered on at the same tim... | [
"Understanding Interfaces"
] | |
show chassis fpc errors | show chassis fpc errors; | Display chassis error information including FPC number, severity of error, number of error occurred,
cleared, threshold, and corresponding action.
Error Severity Level
Default Threshold
Default Action
Fatal
Restart the FPC
Major
Get the current state of the FPC and raise an alarm.
(Continued)
Error Severity Level
De... | [
{
"name": "detail",
"desc": "Display the entire list of errors that contribute to a failure for all the FPCs."
},
{
"name": "fpc-slot",
"desc": "Display the list of errors pertaining to the FPC installed in a particular slot"
}
] | view
Output Fields
Table 317 on page 19146 lists the output fields for the show chassis fpc errors command. Output fields
are listed in the approximate order in which they appear.
Table 317: show chassis fpc errors Output Fields
Field Name
Field Description
FPC
The FPC number.
Table 317: show chassis fpc errors Output... | Command introduced in Junos OS Release 12.3.
Reset PFE output option added in Junos OS Release 21.4R3. | [] | |
show chassis fpc ether-types | show chassis fpc ether-types
<slot-number> | Display the current EtherType values in ternary content addressable memory (TCAM) on a device for a
specified FPC slot or for all currently active (online) FPCs on the device.
Ethernet frame headers contain an EtherType field to identify the protocol in the frame's payload so that
a receiving device knows how to proces... | [
{
"name": "none",
"desc": "Display the EtherType values in TCAM for all active (online) FPC slots."
},
{
"name": "slot-number",
"desc": "(Optional) Display the EtherType values in TCAM for the specified FPC slot number."
}
] | view
Output Fields
Table 318 on page 19151 lists the output fields for the show chassis fpc ether-types command.
Table 318: show chassis fpc ether-types Output Fields
Field Name
Field Description
FPC
FPC slot number.
INDEX
Index in the EtherTypes TCAM table.
NOTE: Indexes 0-5 and 28-31 are reserved. You can't set custo... | Introduced in Junos OS Release 21.1R1. | [] | |
show chassis fpc global pfe-id | show chassis fpc global pfe-id | Display the global pfe-id. The devices supported are MX10004, MX10008, MX10016, MX2010, and
MX2020. The outputs are independent of the line card and the status of the FPC or PFE. This output is
based on the chassis and the fabric card.
Additional Information
The output is displayed independent of the line card and the... | [] | view
Output Fields
Table 319 on page 19156 lists the output fields for the show chassis fpc global pfe-id command.
Table 319: show chassis fpc global pfe-id Output Fields
Field Name
Field Description
FPC
FPC slot number of the Flexible PIC Concentrator (FPC).
Global PFE ID
Unique Identifier for a PFE in a chassis.
Loca... | Command introduced in Junos OS Release 21.4R1. | [] | |
show chassis fpc optical-properties alarms | show chassis fpc optical-properties alarms fpc-slot fpc-slot | IPLC fpc-slot Inter Diag
The IPLC is in the diagnostics mode.
IPLC fpc-slot Firmware Inconsistent
The IPLC firmware is inconsistent with the software or
hardware.
NOTE: If you see this alarm, upgrade your firmware
by using the "request chassis fpc optical-module
firmware-upgrade" on page 15023 command.
IPLC fpc-slot OC... | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the IPLC module resides. Additional Information The alarms provide information about system or component failures on the IPLC. NOTE: The fpc-slot number in the alarms refers to the FPC or PIC in which the IPLC module resides. Table 320: A... | view
Output Fields
Table 321: <name-of-command> Output Fields
Field Name
Field Description
Module
Component on which the alarm is triggered.
Active
FPC or PIC slot number where the active alarm is
triggered.
Table 321: <name-of-command> Output Fields (Continued)
Field Name
Field Description
Alarms
Alarm that is trigge... | Statement introduced in Junos OS Release 15.1F6 and 17.1R1. | [
"Integrated Photonic Line Card Base and Expansion Module Overview",
"Understanding the Integrated Photonic Line Card Architecture"
] | |
show chassis fpc optical-properties amplifier-chain ila alarms | show chassis fpc optical-properties amplifier-chain ila alarms fpc-slot fpc-slot ila-number ila-
number | Corrective Action
IPLC fpc-slot ILA ila-number EDFA
B-A Input LOS
EDFA B-A input power alarm. If the
input power is within 1.5 dB of the
threshold for the minimum input
power, an alarm is triggered.
B-A is the B to A direction (for
example, west to east).
When the input power is at least
1.5 dB greater than the thresho... | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the integrated photonic line card (IPLC) module resides."
},
{
"name": "ila-number",
"desc": "The number assigned to the optical ILA."
}
] | view
Output Fields
Table 322 on page 19164 lists the output fields for the show chassis fpc optical-properties amplifier-
chain ila alarms command. Output fields are listed in the approximate order in which they appear.
Table 322: show chassis fpc optical-properties amplifier-chain ila alarms Output Fields
Field Name
... | Statement introduced in Junos OS Release 17.1R1. | [
"Understanding Optical Supervisory Channel Communication in the Amplifier Chain",
"Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated",
"Photonic Line System",
"Example: Configuring the Optical Supervisory Channel for the Integrated Photonic Line System and",
"O... | |
show chassis fpc optical-properties amplifier-chain ila edfa | show chassis fpc optical-properties amplifier-chain ila edfa fpc-slot fpc-slot ila-number ila-
number | Displays the status information about a particular erbium-doped fiber amplifier (EDFA) for the optical
inline amplifier (ILA). There are two EDFAs in the optical ILA: one is responsible for A to B direction (for
example, east to west) and is called EDFA-A-B; the other one is responsible for B to A direction (for
exampl... | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the integrated photonic line card (IPLC) module resides."
},
{
"name": "ila-number",
"desc": "The number assigned to the optical ILA."
}
] | view
Output Fields
Table 324 on page 19172 lists the output fields for the show chassis fpc optical-properties amplifier-
chain ila edfa command. Output fields are listed in the approximate order in which they appear.
Table 324: show chassis fpc optical-properties amplifier-chain ila edfa Output Fields
Field Name
Fiel... | Statement introduced in Junos OS Release 17.1R1. | [
"Understanding Optical Supervisory Channel Communication in the Amplifier Chain",
"Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated",
"Photonic Line System",
"Example: Configuring the Optical Supervisory Channel for the Integrated Photonic Line System and",
"O... | |
show chassis fpc optical-properties amplifier-chain ila osc | show chassis fpc optical-properties amplifier-chain ila osc fpc-slot fpc-slot ila-number ila-
number | Display the status information about a particular optical supervisory channel (OSC) for the optical inline
amplifier (ILA). There are two OSCs (OSC A and OSC B) in the optical ILA. | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the integrated photonic line card (IPLC) module resides."
},
{
"name": "ila-number",
"desc": "The number assigned to the optical ILA."
}
] | view
Output Fields
Table 325 on page 19177 lists the output fields for the show chassis fpc optical-properties amplifier-
chain ila osc command. Output fields are listed in the approximate order in which they appear.
Table 325: show chassis fpc optical-properties amplifier-chain ila osc Output Fields
Field Name
Field ... | Statement introduced in Junos OS Release 17.1R1. | [
"Understanding Optical Supervisory Channel Communication in the Amplifier Chain",
"Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated",
"Photonic Line System"
] | |
show chassis fpc optical-properties amplifier-chain ila pm-current | show chassis fpc optical-properties amplifier-chain ila pm-current fpc-slot fpc-slot ila-number
ila-number | EDFA A-B Pump 0 Temperature(C), EDFA B-A Pump 0
Temperature(C)
EDFA’s pump 0 temperature for EDFA A-B or B-A.
EDFA A-B Pump 1 Temperature(C), EDFA B-A Pump 1
Temperature(C)
EDFA’s pump 1 temperature for EDFA A-B or B-A.
Sample Output
show chassis fpc optical-properties amplifier-chain ila pm-current
user@host> show cha... | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the integrated photonic line card (IPLC) module resides."
},
{
"name": "ila-number",
"desc": "The number assigned to the optical ILA."
}
] | view
Output Fields
Table 326 on page 19179 lists the output fields for the show chassis fpc optical-properties amplifier-
chain ila pm-current command. Output fields are listed in the approximate order in which they appear.
Table 326: show chassis fpc optical-properties pm-current Output Fields
Field Name
Field Descrip... | Statement introduced in Junos OS Release 17.1R1. | [
"Understanding Optical Supervisory Channel Communication in the Amplifier Chain",
"Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated",
"Photonic Line System",
"Example: Configuring the Optical Supervisory Channel for the Integrated Photonic Line System and",
"O... | |
show chassis fpc optical-properties amplifier-chain ila pm-currentday | show chassis fpc optical-properties amplifier-chain ila pm-currentday fpc-slot fpc-slot ila-
number ila-number | OSC-A Fiber Loss(0.01 dB), OSC-B Fiber Loss(0.01 dB)
OSC fiber loss value (for OSC A or B) The unit is dBm.
Line OUT VOA-A(0.01 dB), Line OUT VOA-B(0.01 dB)
Line out variable optical attenuator (VOA) value (A or
B)
EDFA A-B Input Power(0.01 dBm), EDFA B-A Input
Power(0.01 dBm)
Erbium-doped fiber amplifier (EDFA) input ... | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the integrated photonic line card (IPLC) module resides."
},
{
"name": "ila-number",
"desc": "The number assigned to the online ILA."
}
] | view
Output Fields
Table 328 on page 19184 lists the output fields for the show chassis fpc optical-properties amplifier-
chain ila pm-currentday command. Output fields are listed in the approximate order in which they
appear.
Table 328: show chassis fpc optical-properties amplifier-chain ila pm-currentday Output Field... | Statement introduced in Junos OS Release 17.1R1. | [
"Understanding Optical Supervisory Channel Communication in the Amplifier Chain",
"Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated",
"Photonic Line System",
"Example: Configuring the Optical Supervisory Channel for the Integrated Photonic Line System and",
"O... | |
show chassis fpc optical-properties amplifier-chain ila pm-interval | show chassis fpc optical-properties amplifier-chain ila pm-interval fpc-slot fpc-slot ila-number
ila-number | Displays current performance data during a 15-minute interval for the optical inline amplifier (ILA). | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the integrated photonic line card (IPLC) module resides."
},
{
"name": "ila-number",
"desc": "Optical ILA number in the chain."
}
] | view
Output Fields
Table 330 on page 19188 lists the output fields for the show chassis fpc optical-properties amplifier-
chain ila pm-interval command. Output fields are listed in the approximate order in which they appear.
Table 330: show chassis fpc optical-properties amplifier-chain ila pm-interval Output Fields
Fi... | Statement introduced in Junos OS Release 17.1R1. | [
"Understanding Optical Supervisory Channel Communication in the Amplifier Chain",
"Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated",
"Photonic Line System",
"Example: Configuring the Optical Supervisory Channel for the Integrated Photonic Line System and",
"O... | |
show chassis fpc optical-properties amplifier-chain ila pm-previousday | show chassis fpc optical-properties amplifier-chain ila pm-previousday fpc-slot fpc-slot ila-
number ila-number | OSC-A Fiber Loss(0.01 dB), OSC-B Fiber Loss(0.01 dB)
OSC fiber loss value (for OSC A or B) The unit is dBm.
Line OUT VOA-A(0.01 dB), Line OUT VOA-B(0.01 dB)
Line out variable optical attenuator (VOA) value (A or
B)
EDFA A-B Input Power(0.01 dBm), EDFA B-A Input
Power(0.01 dBm)
Erbium-doped fiber amplifier (EDFA) input ... | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the integrated photonic line card (IPLC) module resides."
},
{
"name": "ila-number",
"desc": "The optical ILA number."
}
] | view
Output Fields
Table 332 on page 19193 lists the output fields for the show chassis fpc optical-properties amplifier-
chain ila pm-previousday command. Output fields are listed in the approximate order in which they
appear.
Table 332: show chassis fpc optical-properties amplifier-chain ila pm-previousday Output Fie... | Statement introduced in Junos OS Release 17.1R1. | [
"Understanding Optical Supervisory Channel Communication in the Amplifier Chain",
"Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated",
"Photonic Line System",
"Example: Configuring the Optical Supervisory Channel for the Integrated Photonic Line System and",
"O... | |
show chassis fpc optical-properties amplifier-chain ila summary | show chassis fpc optical-properties amplifier-chain ila summary fpc-slot fpc-slot ila-number ila-
number | Display detailed information for the optical inline amplifier (ILA) such as the manufacturing details,
power and temperature information, fan information, and so on. | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the integrated photonic line card (IPLC) module resides."
},
{
"name": "ila-number",
"desc": "The number assigned to the optical ILA."
}
] | view
Output Fields
Table 334 on page 19197 lists the output fields for the show chassis fpc optical-properties amplifier-
chain ila summary command. Output fields are listed in the approximate order in which they appear.
Table 334: show chassis fpc optical-properties amplifier-chain ila summary Output Fields
Field Name... | Statement introduced in Junos OS Release 17.1R1. | [
"Understanding Optical Supervisory Channel Communication in the Amplifier Chain",
"Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated",
"Photonic Line System",
"Example: Configuring the Optical Supervisory Channel for the Integrated Photonic Line System and",
"O... | |
show chassis fpc optical-properties amplifier-chain ila voa | show chassis fpc optical-properties amplifier-chain ila voa fpc-slot fpc-slot ila-number ila-
number | Display the status information about a particular variable optical attenuator (VOA) for an optical inline
amplifier (ILA). There are two VOAs (VOA A and VOA B) in the optical ILA. | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the integrated photonic line card (IPLC) module resides."
},
{
"name": "ila-number",
"desc": "The number assigned to the optical ILA."
}
] | view
Output Fields
Table 335 on page 19201 lists the output fields for the show chassis fpc optical-properties amplifier-
chain ila voa command. Output fields are listed in the approximate order in which they appear.
Table 335: show chassis fpc optical-properties amplifier-chain ila voa Output Fields
Field Name
Field D... | Statement introduced in Junos OS Release 17.1R1. | [
"Understanding Optical Supervisory Channel Communication in the Amplifier Chain",
"Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated",
"Photonic Line System",
"Example: Configuring the Optical Supervisory Channel for the Integrated Photonic Line System and",
"O... | |
show chassis fpc optical-properties amplifier-topology | show chassis fpc optical-properties amplifier-topology fpc-slot fpc-slot | Display the topology information for the integrated photonic line card (IPLC) and the optical inline
amplifier (ILA). | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the IPLC module resides."
}
] | view
Output Fields
Table 336 on page 19204 lists the output fields for the show chassis fpc optical-properties amplifier-
topology command. Output fields are listed in the approximate order in which they appear.
Table 336: show chassis fpc optical-properties amplifier-topology Output Fields
Field Name
Field Descriptio... | Statement introduced in Junos OS Release 17.1R1. | [
"Understanding Optical Supervisory Channel Communication in the Amplifier Chain"
] | |
show chassis fpc optical-properties edfa | show chassis fpc optical-properties edfa fpc-slot fpc-slot | Display the erbium-doped fiber amplifier (EDFA) properties for the integrated photonic line card (IPLC)
module installed in the Flexible PIC Concentrator (FPC) or PIC slot. | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the IPLC module resides"
}
] | view
Output Fields
Table 337 on page 19206 lists the output fields for the show chassis fpc optical-properties edfa
command. Output fields are listed in the approximate order in which they appear.
Table 337: show chassis fpc optical-properties edfa Output Fields
Field Name
Field Description
EDFA Information
Detailed E... | Statement introduced in Junos OS Release 15.1F6 and 17.1R1. | [
"Integrated Photonic Line Card Base and Expansion Module Overview",
"Understanding the Integrated Photonic Line Card Architecture"
] | |
show chassis fpc optical-properties mfg-info | show chassis fpc optical-properties mfg-info fpc-slot fpc-slot | Display manufacturing details such as module type, software version, boot versions and so on, for the
integrated photonic line card (IPLC) module and hardware components. This information is displayed for
the main board (IPLC), erbium-doped fiber amplifier (EDFA), wavelength selective switch (WSS), and
optical channel ... | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the IPLC module resides"
}
] | view
Output Fields
Table 338 on page 19208 lists the output fields for the show chassis fpc optical-properties mfg info
command. Output fields are listed in the approximate order in which they appear.
Table 338: show chassis fpc optical-properties mfg info Output Fields
Field Name
Field Description
MAIN BOARD
Display m... | Statement introduced in Junos OS Release 15.1F6 and 17.1R1. | [
"Integrated Photonic Line Card Base and Expansion Module Overview",
"Understanding the Integrated Photonic Line Card Architecture"
] | |
show chassis fpc optical-properties ocm | show chassis fpc optical-properties ocm fpc-slot fpc-slot | Display the optical channel monitor (OCM) properties for the integrated photonic line card (IPLC)
module installed in the Flexible PIC Concentrator (FPC) or PIC slot. | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the IPLC module resides"
}
] | view
Output Fields
Table 339 on page 19211 lists the output fields for the show chassis fpc optical-properties ocm
command. Output fields are listed in the approximate order in which they appear.
Table 339: show chassis fpc optical-properties ocm Output Fields
Field Name
Field Description
Wavelength(nm) / Port / Frequ... | Statement introduced in Junos OS Release 15.1F6 and 17.1R1. | [
"Integrated Photonic Line Card Base and Expansion Module Overview",
"Understanding the Integrated Photonic Line Card Architecture"
] | |
show chassis fpc optical-properties pm-current | show chassis fpc optical-properties pm-current fpc-slot fpc-slot | Display the current performance monitors for the integrated photonic line card (IPLC) module installed
in the Flexible PIC Concentrator (FPC) or PIC slot. | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the IPLC module resides"
}
] | view
Output Fields
Table 339 on page 19211 lists the output fields for the show chassis fpc optical-properties pm-current
command. Output fields are listed in the approximate order in which they appear.
Table 340: show chassis fpc optical-properties pm-current Output Fields
Field Name
Field Description
PM
Performance m... | Statement introduced in Junos OS Release 15.1F6 and 17.1R1. | [
"Enabling and Configuring Thresholds on the Integrated Photonic Line Card Performance Monitors",
"Integrated Photonic Line Card Base and Expansion Module Overview",
"Understanding the Integrated Photonic Line Card Architecture"
] | |
show chassis fpc optical-properties pm-currentday | show chassis fpc optical-properties pm-currentday fpc-slot fpc-slot | Displays the performance monitors for the current day for the integrated photonic line card (IPLC)
module installed in the Flexible PIC Concentrator (FPC) or PIC slot. | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the IPLC module resides"
}
] | view
Output Fields
Table 341 on page 19218 lists the output fields for the show chassis fpc optical-properties currentday
command. Output fields are listed in the approximate order in which they appear.
Table 341: show chassis fpc optical-properties pm-currentday Output Fields
Field Name
Field Description
PM
Performanc... | Statement introduced in Junos OS Release 15.1F6 and 17.1R1. | [
"Enabling and Configuring Thresholds on the Integrated Photonic Line Card Performance Monitors",
"Integrated Photonic Line Card Base and Expansion Module Overview",
"Understanding the Integrated Photonic Line Card Architecture"
] | |
show chassis fpc optical-properties pm-interval | show chassis fpc optical-properties pm-interval fpc-slot fpc-slot | Display 15-minute intervals for the performance monitors for the integrated photonic line card (IPLC)
module installed in the Flexible PIC Concentrator (FPC) or PIC slot. | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the IPLC module resides"
}
] | view
Output Fields
Table 342 on page 19223 lists the output fields for the show chassis fpc optical-properties pm-interval
command. Output fields are listed in the approximate order in which they appear.
Table 342: show chassis fpc optical-properties pm-interval Output Fields
Field Name
Field Description
PM
Performanc... | Statement introduced in Junos OS Release 15.1F6 and 17.1R1. | [
"Enabling and Configuring Thresholds on the Integrated Photonic Line Card Performance Monitors",
"Integrated Photonic Line Card Base and Expansion Module Overview",
"Understanding the Integrated Photonic Line Card Architecture"
] | |
show chassis fpc optical-properties pm-previousday | show chassis fpc optical-properties pm-previousday fpc-slot fpc-slot | Display performance monitors for the previous 24-hour period for the integrated photonic line card
(IPLC) module installed in the Flexible PIC Concentrator (FPC) or PIC slot. | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the IPLC module resides"
}
] | view
Output Fields
Table 343 on page 19227 lists the output fields for the show chassis fpc optical-properties pm-
previousday command. Output fields are listed in the approximate order in which they appear.
Table 343: show chassis fpc optical-properties pm-previousday Output Fields
Field Name
Field Description
PM
Perf... | Statement introduced in Junos OS Release 15.1F6 and 17.1R1. | [
"Enabling and Configuring Thresholds on the Integrated Photonic Line Card Performance Monitors",
"Integrated Photonic Line Card Base and Expansion Module Overview",
"Understanding the Integrated Photonic Line Card Architecture"
] | |
show chassis fpc optical-properties status | show chassis fpc optical-properties status fpc-slot fpc-slot | Display the operational status of the integrated photonic line card (IPLC) module installed in the Flexible
PIC Concentrator (FPC) or PIC slot. | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the IPLC module resides. Additional Information To enable and configure the IPLC performance monitors. See Enabling and Configuring Thresholds on the Integrated Photonic Line Card Performance Monitors."
}
] | view
Output Fields
Table 344 on page 19232 lists the output fields for the show chassis fpc optical-properties status
command. Output fields are listed in the approximate order in which they appear.
Table 344: show chassis fpc optical-properties status Output Fields
Field Name
Field Description
Uptime
Display how long ... | Statement introduced in Junos OS Release 15.1F6 and 17.1R1. | [
"Integrated Photonic Line Card Base and Expansion Module Overview",
"Understanding the Integrated Photonic Line Card Architecture"
] | |
show chassis fpc optical-properties topology | show chassis fpc optical-properties topology <detail> fpc-slot fpc-slot | Display topology Information about the integrated photonic line card (IPLC) module installed in the
Flexible PIC Concentrator (FPC) or PIC slot. | [
{
"name": "fpc-slot",
"desc": "Slot number of the FPC or PIC in which the IPLC module resides"
},
{
"name": "detail",
"desc": "Displays the blocked wavelengths."
}
] | view
Output Fields
Table 345 on page 19234 lists the output fields for the show chassis fpc optical-properties topology
command. Output fields are listed in the approximate order in which they appear.
Table 345: show chassis fpc optical-properties topology Output Fields
Field Name
Field Description
Wavelength(nm) / Por... | Statement introduced in Junos OS Release 15.1F6 and 17.1R1. | [
"Integrated Photonic Line Card Base and Expansion Module Overview",
"Understanding the Integrated Photonic Line Card Architecture"
] | |
show chassis fpc pic-status (GNF) | show chassis fpc pic-status | Display the status of the physical interface cards (PICs) of each Flexible PIC Concentrator (FPC) assigned
to the guest network function (GNF). | [] | view
Sample Output
command-name
user@router> show chassis fpc pic-status
Slot 4 Online MPC6E 3D GNF 2
PIC 0 Online 24X10GE SFPP
PIC 1 Online 4X100GE CXP
Slot 6 Online MPC7E 3D MRATE-12xQSFPP-XGE-XLGE-CGE GNF 2
PIC 0 Online MRATE-6... | Command introduced before Junos OS Release 7.4. | [] | |
show chassis fpc pic-status (Node Slicing) | show chassis fpc pic-status | Display the status of the physical interface cards (PICs) of each Flexible PIC Concentrator (FPC) assigned
to different guest network functions (GNFs). | [] | view
Sample Output
user@router> show chassis fpc pic-status
command-name
Slot 0 Online MPC5E 3D 24XGE+6XLGE GNF 3
PIC 0 Online 12X10GE SFPP OTN
PIC 1 Offline 12X10GE SFPP OTN
PIC 2 Offline 3X40GE QSFPP
PIC 3 Online 3X40GE QSFPP
Slot 1 Online MPC... | Command introduced before Junos OS Release 7.4. | [] | |
show chassis fpc | show chassis fpc <fpc-slot>
<detail | pic-status | <pfe-instance <pfe-id>> | errors> all | Display status information about the installed Flexible PIC Concentrators (FPCs) and PICs. | [
{
"name": "none",
"desc": "Display status information for all FPCs. NOTE: In EX8200 switches, line cards initialize Packet Forwarding Engine during startup. If an error occurs during hardware initialization, the FPCs with bad hardware parts power down after transferring the debug information to the Routing ... | view
Output Fields
Table 346 on page 19247 lists the output fields for the show chassis fpc command. Output fields are listed
in the approximate order in which they appear.
Table 346: show chassis fpc Output Fields
Field Name
Field Description
Level of Output
Slot or Slot
State
Slot number and state. The state can be ... | Command introduced before Junos OS Release 7.4.
pfe-instance option added in Junos OS Evolved Release 21.4R1. | [] | |
show chassis fpc-feb-connectivity | show chassis fpc-feb-connectivity | (M120 router only) Display the Flexible PIC Concentrator (FPC) and Forwarding Engine Board (FEB)
mapping and their respective states. | [] | view
Output Fields
Table 347 on page 19295 lists the output fields for the show chassis fpc-feb-connectivity command. Output
fields are listed in the approximate order in which they appear.
Table 347: show chassis fpc-feb-connectivity Output Fields
Field Name
Field Description
FPC
Slot number of the Flexible PIC Concen... | Command introduced in Junos OS Release 8.0. | [
"Resynchronizing FPC Sequence Numbers with Active FPCs when an FPC Comes Online",
"MX960 Flexible PIC Concentrator Description"
] | |
show chassis gnf | show chassis gnf | Display information about the guest network function (GNF) you logged in. | [] | view
Output Fields
Table 348 on page 19299 lists the output fields for the show chassis gnf command. Output fields are listed
in the approximate order in which they appear.
Table 348: show chassis gnf Output Fields
Field Name
Field Description
GNF ID
Shows the GNF ID.
GNF State
Status of the GNF.
•
Online—GNF online an... | Command introduced in Junos OS Release 18.2R1. | [] | |
show chassis hardware (GNF) | show chassis hardware | Brief description of the hardware item.
Sample Output
command-name
user@router> show chassis hardware
bsys-re0:
--------------------------------------------------------------------------
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN11C... | [] | view
Output Fields
Table 349 on page 19302 lists the output fields for the show chassis hardware command. Output fields are
listed in the approximate order in which they appear.
Table 349: show chassis hardware Output Fields
Field Name
Field Description
Item
Chassis component:
•
Information about the backplane, Routin... | Command introduced before Junos OS Release 7.4. | [] | |
show chassis hardware (View) | show chassis hardware
<clei-models>
<detail | extensive>
<models>
<node(node-id | all | local | primary)> | Brief description of the hardware item:
•
Type of power supply.
•
Switch Control Board (SCB)
Starting with Junos OS Release 12.1X47-D15 and Junos OS Release
17.3R1, the SRX5K-SCBE (SCB2) is introduced.
•
There are three SCB slots in SRX5800 devices. The third slot can be
used for an SCB or an FPC. When an SRX5K-SCB was... | [
{
"name": "clei-models",
"desc": "(Optional) Display Common Language Equipment Identifier Code (CLEI) barcode and"
},
{
"name": "detail | extensive",
"desc": "(Optional) Display the specified level of output."
},
{
"name": "models",
"desc": "(Optional) Display model numbers and part ... | view
Output Fields
Table 351 on page 19306 lists the output fields for the show chassis hardware command. Output fields are
listed in the approximate order in which they appear.
Table 351: show chassis hardware Output Fields
Field Name
Field Description
Item
Chassis component—Information about the backplane; power supp... | Command introduced in Junos OS Release 9.2. Command modified in Junos OS Release 9.2 to include
node option. | [
"Understanding Traffic Processing on Security Devices",
"Interface Naming Conventions"
] | |
show chassis hardware | show chassis hardware
<detail | extensive>
<clei-models>
<interconnect-device name>
<node-device name>
<models> | [
{
"name": "none",
"desc": "Display information about hardware. For a TX Matrix router, display information about the TX Matrix router and its attached T640 devices. For a TX Matrix Plus router, display information about the TX Matrix Plus router and its attached devices."
},
{
"name": "clei-models",... | view
Output Fields
Table 353: <name-of-command> Output Fields
Field Name
Field Description
Level of Output
Item
Show information about the device
hardware.
All levels
Version
Revision level of the chassis
component.
All levels
Part number
Part number of the chassis
component.
All levels
Serial number
Serial number of ... | Command introduced before Junos OS Release 7.4.
models option introduced in Junos OS Release 8.2.
sfc option introduced in Junos OS Release 9.6 for the TX Matrix Plus router.
Information for disk and usb introduced in Junos OS Release 15.1X53-D60 for QFX10002, QFX10008,
and QFX10016 switches.
pem detail output added in... | [
"show chassis power"
] | ||
show chassis hardware | show chassis hardware
<detail | extensive>
<clei-models>
<interconnect-device name>
<node-device name>
<models> | Brief description of the hardware item:
•
Type of power supply.
•
Type of PIC. If the PIC type is not supported on the current software
release, the output states Hardware Not Supported.
•
Type of FPC: FPC Type 1, FPC Type 2, FPC Type 3, FPC Type 4 , or FPC
TypeOC192.
On EX Series switches, a brief description of the F... | [
{
"name": "none",
"desc": "Display information about hardware. For a TX Matrix router, display information about the TX Matrix router and its attached T640 devices. For a TX Matrix Plus router, display information about the TX Matrix Plus router and its attached devices."
},
{
"name": "clei-models",... | view
Output Fields
Table 355 on page 19355 lists the output fields for the show chassis hardware command. Output fields are
listed in the approximate order in which they appear.
Table 355: show chassis hardware Output Fields
Field Name
Field Description
Level of Output
Item
Show information about the device hardware.
A... | Command introduced before Junos OS Release 7.4.
models option introduced in Junos OS Release 8.2.
sfc option introduced in Junos OS Release 9.6 for the TX Matrix Plus router.
Information for disk and usb introduced in Junos OS Release 15.1X53-D60 for QFX10002, QFX10008,
and QFX10016 switches.
pem detail output added i... | [] | |
show chassis high-availability data-plane statistics | show chassis high-availability data-plane statistics
<ICL/IDL> | Display Multinode High Availability data plane statistics. The command displays various types of RTO
counters—both sent and received—over ICL and IDL links.
If ICL or IDL is not explicitly specified, the command by default shows ICL RTO data, aligning with the 2-
node MNHA configuration. | [] | view
Output Fields
Table 356: show chassis cluster data-plane statistics Output Fields
Field Name
Field Description
Services Synchronized
•
Service name—Name of the service.
•
Translation context—Messages synchronizing Network Address Translation
(NAT) translation context.
•
Incoming NAT—Messages synchronizing incomin... | Command introduced in Junos OS Release 20.4R1. | [] | |
show chassis high-availability information | show chassis high-availability information | Display details of the Multinode High Availability status on your security device including health status
of the peer node. | [] | view
Output Fields
Table 357 on page 19385 lists the output fields for the show chassis high-availability information
command. Output fields are listed in the approximate order in which they appear.
Table 357: show chassis high-availability information
Field Name
Field Description
Node failure codes
Node failure codes ... | Command introduced in Junos OS Release 20.4R1. | [
"Example: Configure Multinode High Availability in a Layer 3 Network"
] | |
show chassis high-availability peer-info | show chassis high-availability peer-info | Display details of the peer node in a Multinode High Availability setup. Use this command to gather
details of peer node, connection details, and packet statistics. | [] | view
Output Fields
Table 358 on page 19404 lists the output fields for the show chassis high-availability information
command. Output fields are listed in the approximate order in which they appear.
Table 358: show chassis high-availability peer-info
Field Name
Field Description
HA Peer Information
•
Description—peer ... | Command introduced in Junos OS Release 22.3R1. | [
"Example: Configure Multinode High Availability in a Layer 3 Network"
] | |
show chassis high-availability prefix-srgid-table | show chassis high-availability prefix-srgid-table | Display mapping of prefix list with SRGs. | [] | view
Output Fields
Table 359 on page 19406 lists the output fields for the show chassis high-availability information
command. Output fields are listed in the approximate order in which they appear.
Table 359: show chassis high-availability prefix-srgid-table
Field Name
Field Description
SRGID
SRG identification number... | Command introduced in Junos OS Release 22.4R1. | [] | |
show chassis high-availability services-redundancy-group | show chassis high-availability services-redundancy-group services-redundancy-group-id | monitor-
object object-name | Display the service redundancy group information in a Multinode High Availability setup. | [] | view
Output Fields
Table 360 on page 19408 lists the output fields for the show chassis high-availability services-redundancy-
group command. Output fields are listed in the approximate order in which they appear.
Table 360: show chassis high-availability services-redundancy-group
Field Name
Field Description
SRG fail... | Command introduced in Junos OS Release 20.4R1. | [
"Example: Configure Multinode High Availability in a Layer 3 Network"
] | |
show chassis in-service-upgrade | show chassis in-service-upgrade | Display the status of Flexible PIC Concentrators (FPCs) and their corresponding PICs after the most
recent unified in-service software upgrade (ISSU). This command must be issued on the primary Routing
Engine.
NOTE: Only Intelligent Queuing (IQ) PICs are displayed by this command output. Unified
ISSU status for other ... | [] | view
Output Fields
Table 361 on page 19419 lists the output fields for the show chassis in-service-upgrade command. Output
fields are listed in the approximate order in which they appear.
Table 361: show chassis in-service-upgrade Output Fields
Field Name
Field Description
Item
Flexible PIC Concentrator (FPC) slot numb... | Command introduced in Junos OS Release 9.0. | [
"Getting Started with Unified In-Service Software Upgrade",
"Example: Performing a Unified ISSU"
] | |
show chassis interoperability | show chassis interoperability | Show chassis interoperability mode
Sample Output
show chassis interoperability (Default mode for PTX device with PTX10K-LC1301-36DD line
card)
show chassis interoperability
Chassis Interoperability Mode: express-interop
show chassis interoperability (express5 mode for PTX device with PTX10K-LC1301-36DD
line card)
show... | [] | [] | |||
show chassis jnu satellite | show chassis jnu satellite [device-list value] | Display the status, model, and Junos OS version of all the JNU Satellites that joined the JNU Controller
in Junos Node Unifier (JNU) topology. You can also designate a specific device name to obtain its details. | [
{
"name": "device-list value",
"desc": "(optional) Specify a device value from the available list"
}
] | view
Output Fields
This section lists the output fields for the show chassis jnu satellites command.
Table 362: show chassis jnu satellites Output Fields
Field Name
Field Description
Satellite
Shows the name(s) of the satellite nodes
Alive
Shows the status of the satellite nodes
Model
Displays the satellite node model
... | Command introduced in Junos OS Release 24.4R1. | [
"Junos Node Unifier for CSDS"
] | |
show chassis lcd | Display the information that appears on the LCD panel of EX3200, EX3300, EX4200, EX4500, EX6200,
and EX8200 switches, XRE200 External Routing Engines, QFX Series standalone switches, OCX Series
switches, and Interconnect devices and Node devices within a QFabric system. Display the status of the
currently selected port... | [
{
"name": "none",
"desc": "Display the information that appears on the LCD panel (for any EX Series member switch in a Virtual Chassis or for XRE200 External Routing Engines, display the information for all Virtual Chassis members). Display the status of the currently selected port parameter of the Status L... | view
Output Fields
Table 363 on page 19429 lists the output fields for the show chassis lcd command. Output fields are listed
in the approximate order in which they appear.
Table 363: show chassis lcd Output Fields
Field Name
Field Description
membernumber (XRE200 External
Routing Engine)
Member ID of the device whose ... | Command introduced in Junos OS Release 9.0.
menu option introduced in Junos OS Release 10.2 for EX Series switches. | [
"LCD Panel in EX3200 Switches",
"LCD Panel in EX4200 Switches",
"LCD Panel in EX4500 Switches",
"LCD Panel in an EX8200 Switch",
"LCD Panel in an XRE200 External Routing Engine",
"Configuring the LCD Panel on EX Series Switches (CLI Procedure)"
] | ||
show chassis led satellite | show chassis led satellite [slot-id slot-id |device-alias alias-name] | Display the status and colors of the chassis LEDs of the satellite devices in a Junos Fusion. A major alarm
(red) indicates a critical error condition that requires immediate action. A minor alarm (yellow) indicates a
noncritical condition that requires monitoring or maintenance. A minor alarm that is left unchecked
mi... | [
{
"name": "none",
"desc": "Display the status of the chassis status LEDs of every satellite device in the Junos Fusion."
},
{
"name": "slot-id slot-id",
"desc": "(Optional) Display the status of the chassis status LEDs of the satellite device using the specified FPC slot identifier in the Junos ... | view
Output Fields
Table 364 on page 19447 lists the output fields for the show chassis led satellite command. Output fields
are listed in the approximate order in which they appear.
Table 364: show chassis led Output Fields
Field Name
Field Description
Beacon LED
(Applies when QFX5100, QFX5110, and QFX5200 switches a... | Command introduced in Junos OS Release 14.2R3. | [
"Configuring Satellite Device Alarm Handling Using an Environment Monitoring Satellite Policy in a",
"Junos Fusion",
"Understanding Junos Fusion Provider Edge Components",
"Understanding Junos Fusion Enterprise Components"
] | |
show chassis led | show chassis led
<fpc-slot <fpc-slot-number>> | Display the status and colors of the chassis LEDs on the front panel of the switch. A major alarm (red)
indicates a critical error condition that requires immediate action. A minor alarm (yellow) indicates a
noncritical condition that requires monitoring or maintenance. A minor alarm that is left unchecked
might cause ... | [
{
"name": "none",
"desc": "Display the status of the chassis status LEDs (for EX4200 switches configured as a Virtual Chassis, display the information for all Virtual Chassis members; for EX4300, display the LED status only for ports in PIC 0 and PIC 1)."
},
{
"name": "fpc-slot <fpc-slot-number>",
... | view
Output Fields
Table 365 on page 19453 lists the output fields for the show chassis led command. Output fields are listed
in the approximate order in which they appear.
Table 365: show chassis led Output Fields
Field Name
Field Description
Front panel contents for slot
Front panel contents (EX8200 Switches)
Front P... | Command introduced in Junos OS Release 10.1. | [
"Chassis Status LEDs in EX2200 Switches",
"Chassis Status LEDs in EX3200 Switches",
"Chassis Status LEDs in EX4200 Switches",
"Chassis Status LEDs in EX4500 Switches",
"Chassis Status LEDs in an EX8200 Switch",
"Chassis Status LEDs on a QFX3500 Device",
"Chassis Status LEDs in the QFX3600 and QFX3600-I ... | |
show chassis location | show chassis location
<interconnect-device name>
<node-device name> | Display the physical location of the chassis. This command can only be used on the primary Routing
Engine. | [
{
"name": "none",
"desc": "Display all information about the physical location of the chassis. On a TX Matrix router, display all information about the physical location of the TX Matrix router and its attached T640 routers. On a TX Matrix Plus router, display all information about the physical location of ... | view
Output Fields
Table 366 on page 19471 lists the output fields for the show chassis location command. Output fields are
listed in the approximate order in which they appear.
Table 366: show chassis location Output Fields
Field Name
Field Description
country-code
Country code information.
postal-code
Postal code inf... | Command introduced before Junos OS Release 7.4.
sfc option introduced for the TX Matrix Plus router in Junos OS Release 9.6. | [
"Displaying Chassis Physical Locations for a Routing Matrix with a TX Matrix Plus Router"
] | |
show chassis mac-addresses | show chassis mac-addresses
<interconnect-device name>
<node-group name> | Display the media access control (MAC) addresses for the router, switch chassis, or switch. | [
{
"name": "none",
"desc": "(TX Matrix, TX Matrix Plus routers, QFX Series, and OCX Series Switches) Display the MAC addresses for the router chassis or switch. On a TX Matrix router, display MAC addresses on the TX Matrix router and its attached T640 routers. On a TX Matrix Plus router, display MAC addresse... | view
Output Fields
Table 367 on page 19476 lists the output fields for the show chassis mac-addresses command. Output fields
are listed in the approximate order in which they appear.
Table 367: show chassis mac-addresses Output Fields
Field Name
Field Description
MAC address information
Table 367: show chassis mac-add... | Command introduced before JUNOS Release 7.4.
sfc option introduced for the TX Matrix Plus router in JUNOS Release 9.6. | [
"ACX2000 and ACX2100 Routers Hardware and CLI Terminology Mapping"
] | |
show chassis network-services | show chassis network-services | Display the network services mode that the router is configured to run in—IP Network Services mode,
Ethernet Network Services mode, Enhanced IP Network Services mode, Enhanced Ethernet Network
Services mode, or Enhanced mode. | [
{
"name": "all-ethernet",
"desc": "All Ethernet network services"
},
{
"name": "all-ip",
"desc": "All IP network services"
},
{
"name": "enhanced-ethernet",
"desc": "Enhanced ethernet network services"
},
{
"name": "enhanced-ip",
"desc": "Enhanced IP network services"
}... | view
Output Fields
Table 368 on page 19484 lists the output fields for the show chassis network services command. Output
fields are listed in the approximate order in which they appear.
Table 368: show chassis network services Output Fields
Field Name
Field Description
Network Services
Mode
Network services mode confi... | Command introduced in Junos OS Release 9.4. | [] | |
show chassis network-slices fpcs | show chassis network-slices fpcs | Display information about the FPCs associated with different guest network functions (GNFs). | [] | view
Output Fields
Table 369 on page 19487 lists the output fields for the show chassis network-slices fpcs command. Output
fields are listed in the approximate order in which they appear.
Table 369: show chassis network-slices fpcs Output Fields
Field Name
Field Description
GNF
GNF ID.
FPCs
Slot numbers of FPCs assoc... | Command introduced in Junos OS Release 17.2R1. | [] | |
show chassis network-slices | show chassis network-slices
<gnf gnf-id> | Description of the guest network function.
State
Status of the GNF.
•
Online—GNF online and running.
•
Offline—GNF is offline.
Uptime
Duration for which the GNFs have been up and running. In case of a GNF Routing Engine
switchover, the uptime value is reset as the new primary GNF Routing Engine establishes a
fresh conn... | [] | view
Output Fields
Table 370 on page 19489 lists the output fields for the show chassis network-slices command. Output
fields are listed in the approximate order in which they appear.
Table 370: show chassis network-slices Output Fields
Field Name
Field Description
GNF
GNF identifier for each partition. | Command introduced in Junos OS Release 17.2R1. | [] | |
show chassis nonstop-upgrade node-group | show chassis nonstop-upgrade node-group node-group-name | Display the status of the Node group after the most recent nonstop software upgrade (NSSU). | [] | view
Output Fields
Table 371 on page 19493 lists the output fields for the show chassis nonstop-upgrade node-group command.
Output fields are listed in the approximate order in which they appear.
Table 371: show chassis nonstop-upgrade node-group Output Fields
Field Name
Field Description
Item
Node device slot number.
... | Command introduced in Junos OS Release 12.2. | [
"Performing a Nonstop Software Upgrade on the QFabric System"
] | |
show chassis nonstop-upgrade | show chassis nonstop-upgrade | (EX6200 switches, EX8200 switches, EX8200 Virtual Chassis, QFX3500 and QFX3600 Virtual Chassis,
and Virtual Chassis Fabric only) Display the status of the line cards or Virtual Chassis members in the
linecard role after the most recent nonstop software upgrade (NSSU). You must issue this command on
the primary Routing ... | [] | view
Output Fields
Table 372 on page 19495 lists the output fields for the show chassis nonstop-upgrade command. Output
fields are listed in the approximate order in which they appear.
Table 372: show chassis nonstop-upgrade Output Fields
Field Name
Field Description
Item
Line card slot number.
Status
State of line car... | Command introduced in Junos OS Release 10.4. | [
"Upgrading Software on an EX6200 or EX8200 Standalone Switch Using Nonstop Software Upgrade",
"(CLI Procedure)",
"Upgrading Software on a Virtual Chassis and Mixed Virtual Chassis Using Nonstop Software Upgrade",
"Upgrading Software on a Virtual Chassis Fabric Using Nonstop Software Upgrade",
"Upgrading Sof... | |
show chassis oss-map | show chassis oss-map | (T4000 routers only) Display the operations support systems (OSS) mapping details. | [] | view
Output Fields
Table 373 on page 19498 lists the output fields for the show chassis oss-map command. Output fields are
listed in the approximate order in which they appear.
Table 373: show chassis oss-map Output Fields
Field Name
Field Description
Chassis type
Displays the original chassis type.
Oss-map
Displays th... | Command introduced in Junos OS Release 12.3R3, 13.1R2, and 13.2R1. | [
"Configuring OSS Mapping to Represent a T4000 Chassis as a T1600 or a T640 Chassis",
"Example: Configuring a T4000 Chassis to Represent a T640 Chassis"
] | |
show chassis pic (Security) | show chassis pic fpc-slot slot-number pic-slot slot-number | Display status information about the PIC installed in the specified Flexible PIC Concentrator (FPC) and
PIC slot. | [
{
"name": "fpc-slot slot-number",
"desc": "Display information about the FPC in the slot."
},
{
"name": "pic-slot slot-number",
"desc": "Display information about the PIC in this particular FPC slot."
}
] | view
Output Fields
Table 374 on page 19500 lists the output fields for the show chassis pic command. Output fields are
listed in the approximate order in which they appear.
Table 374: show chassis pic Output Fields
Field Name
Field Description
Type
PIC type.
State
Status of the PIC. State is displayed only when a PIC i... | Command introduced in Junos OS Release 9.2. | [
"Interfaces User Guide for Security Devices",
"Understanding Traffic Processing on Security Devices"
] | |
show chassis pic | show chassis pic
(fpc-slot slot-number | pic-slot slot-number) | Display status information about the PIC installed in the specified Flexible PIC Concentrator (FPC) and
PIC slot. Displays additional PFE and telemetry information for monitoring of optical module as FRU on
MX10K and PTX10K series routers. | [
{
"name": "fpc-slot slot-number",
"desc": "Display information about the PIC in this particular FPC slot:"
},
{
"name": "M120 routers only",
"desc": "Replace slot-number with a value from 0 through 5."
},
{
"name": "MX80 routers only",
"desc": "Replace slot-number with a value from 0... | view
Output Fields
Table 375 on page 19506 lists the output fields for the show chassis pic command. Output fields are
listed in the approximate order in which they appear.
Table 375: show chassis pic Output Fields
Field Name
Field Description
Type
PIC type.
NOTE: On the 1-port OC192/STM64 MICs with the SDH framing mod... | Command introduced before Junos OS Release 7.4.
transport option introduced in Junos OS Release 16.1R1 for MX Series Routers.
Command supports optical module as FRU on MX10K and PTX10K Series Routers starting Junos EVO
Release 25.4R1. | [
"request chassis pic",
"100-Gigabit Ethernet Type 4 PIC with CFP Overview"
] | |
show chassis pic-mode | show chassis pic-mode
<all-members>
<local>
<member member-id> | Display the PIC mode on an EX4500 switch.
The PIC mode must be set to virtual-chassis if the EX4500 switch is cabled into a Virtual Chassis using
the dedicated Virtual Chassis ports (VCPs) on the Virtual Chassis module.
NOTE: This PIC mode setting is not used on an EX4550 switch.
The default PIC mode setting is virtual... | [
{
"name": "none",
"desc": "Display the PIC mode on the member switch where the command is issued."
},
{
"name": "all-members",
"desc": "(Optional) Display the PIC mode for all members of the Virtual Chassis configuration."
},
{
"name": "local",
"desc": "(Optional) Display the PIC mod... | view
Sample Output
show chassis pic-mode
user@switch> show chassis pic-mode
fpc0:
--------------------------------------------------------------------------
Pic Mode: Intraconnect | Command introduced in Junos OS Release 11.1. | [
"Resetting the EX4500 Switch to Run as a Standalone Switch (CLI Procedure)",
"Configuring a Mixed Virtual Chassis with EX4200, EX4500, and EX4550 Member Switches (CLI",
"Procedure)"
] | |
show chassis power (Security) | show chassis power | Display power limits and usage information for the Power Entry Modules (PEMs). | [
{
"name": "node",
"desc": "Displays information specific to the chassis."
},
{
"name": "sequence",
"desc": "Shows the chassis fru power on sequence."
}
] | view
Output Fields
Table 376 on page 19544 lists the output fields for the show chassis power command. Output fields are
listed in the approximate order in which they appear.
Table 376: show chassis power Output Fields
Field Name
Field Description
PEM number
AC or DC PEM number on the chassis. The following output fiel... | Command modified in Junos OS Release 12.1X44-D10. | [
"Understanding Traffic Processing on Security Devices",
"show chassis power sequence"
] | |
show chassis power sequence | show chassis power sequence | (MX Series 5G Universal Routing Platforms only) Show power-on sequence for the chassis Dense Port
Concentrators (DPCs).
(PTX Series Packet Transport Routers, MX2010 and MX2020 routers only) Show power-on sequence for
FPCs installed in the chassis. | [] | view
Output Fields
Table 377 on page 19549 lists the output fields for the show chassis power sequence command. Output
fields are listed in the approximate order in which they appear.
Table 377: show chassis power sequence Output Fields
Field Name
Field Description
Chassis FRU Power
Sequence
(MX Series) Power-on sequen... | Command introduced in Junos OS Release 10.0.
Command introduces in Junos OS Release 12.1 for PTX Series Packet Transport Routers. | [] | |
show chassis power | show chassis power
<all-members>
<extensive>
<detail>
<local>
<member member-id>
<sequence> | Display power limits and usage information for the AC or DC power sources.
NOTE: Review "Platform Specific Behavior" on page 19599 Table for the list of platforms
supporting the show chassis power command and their behaviors. | [
{
"name": "none",
"desc": "Display basic power usage information for the AC and DC power sources."
},
{
"name": "all-members",
"desc": "(MX Series Virtual Chassis only) (Optional) Display power usage information for all members of the Virtual Chassis configuration."
},
{
"name": "detail"... | view
Output Fields
Table 378 on page 19553 lists the output fields for the show chassis power command. Output fields are
listed in the approximate order in which they appear.
Table 378: show chassis power Output Fields:
Field Name
Field Description
Level of Output
PEM number
(EX9200 switches, SRX5800 and MX Series rou... | Command introduced in Junos OS Release 10.0. | [
"Checklist for Monitoring Power Supplies"
] | |
show chassis power-budget-statistics | show chassis power-budget-statistics | Display the power budget of the device. | [] | view
Output Fields
Table 379 on page 19603 lists the output fields for the show chassis power-budget-statistics command.
Output fields are listed in the approximate order in which they appear.
Table 379: show chassis power-budget-statistics Output Fields
Field Name
Field Description
PSU n (supply type)
Capacity rating... | Command introduced in Junos OS Release 10.2. | [
"Verifying Power Configuration and Use",
"Configuring the Power Priority of Line Cards (CLI Procedure)",
"Configuring Power Supply Redundancy (CLI Procedure)"
] | |
show chassis psd | show chassis psd | (Root System Domain [RSD] only) Display information about Protected System Domains (PSDs). A PSD
is initially created by the RSD configuration. An RSD and PSDs are supported on a T320 or T640 router,
or a T1600 routing node, or a TX Matrix Plus Platform that is interconnected with the JCS1200
platform.
NOTE: RSD config... | [] | view
Output Fields
Table 380 on page 19611 lists the output fields for the show chassis psd command. Output fields are listed
in the approximate order in which they appear.
Table 380: show chassis psd Output Fields
Field Name
Field Description
Slot Description
PSD identification.
State
PSD status:
•
Online—PSD is onlin... | Command introduced in Junos OS Release 9.1. | [] | |
show chassis realtime-ukern-thread | show chassis realtime-ukern-thread | Display whether real-time Bidirectional Forwarding Detection (BFD) is enabled or disabled. If real-time
BFD is enabled, the output of the show command displays the value of the realtime Ukern thread Status
field as Enabled. | [] | view
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
show chassis realtime-ukern-thread
user@host> show chassis realtime-ukern-thread
realtime Ukern thread Status: Enabled | Command introduced in Junos OS Release 15.1X49-D100. | [
"Enabling Dedicated and Real-Time BFD",
"Understanding BFD for BGP"
] | |
show chassis redundancy feb | show chassis redundancy feb
<errors>
<redundancy-group group-name> | (M120 routers only) Display information about the status of configured Forwarding Engine Board (FEB)
redundancy groups. | [
{
"name": "none",
"desc": "Display information about the status of all configured FEB redundancy groups."
},
{
"name": "redundancy-group",
"desc": ""
},
{
"name": "group-name",
"desc": "(Optional) Display information about the specified configured redundancy group."
},
{
"nam... | view
Output Fields
Table 381 on page 19615 lists the output fields for the show chassis redundancy feb command. Output
fields are listed in the approximate order in which they appear.
Table 381: show chassis redundancy feb Output Fields
Field name
Field Description
Group
Name of configured redundancy group.
FEB
Slot n... | Command introduced in Junos OS Release 8.2. | [
"Configuring FEB Redundancy on the M120 Router",
"Understanding Switching Control Board Redundancy"
] | |
show chassis redundant-power-system | show chassis redundant-power-system | Display information about the Redundant Power Systems (RPS) connected to the switch. | [] | view
Output Fields
Table 382 on page 19619 lists the output fields for the show chassis redundant-power-system command.
Output fields are listed in the approximate order in which they appear.
Table 382: show chassis redundant-power-system Output Fields
Field Name
Field Description
Level of
Output
Member
Member number ... | Command introduced in Junos OS Release 12.1. | [
"Determining and Setting Priority for Switches Connected to an EX Series RPS"
] | |
show chassis reswatch | show chassis reswatch-config | Display resource usage statistics report. By default, reswatch only logs resource usages when the
monitored resource entered its orange zone. | [] | Output Fields
Table 383 on page 19621 lists the output fields for the show chassis reswatch-config command. Output
fields are listed in the approximate order in which they appear.
Table 383: Show chassis reswatch-config
Field Name
Field Description
Reswatch
Enable or Disable.
CPU statistics count
CPU statistics count v... | Command introduced in Junos OS Release 20.4R1. | [] | |
show chassis routing-engine (View) | show chassis routing-engine | Display the Routing Engine status of the chassis cluster. | [] | view
Output Fields
Table 384 on page 19624 lists the output fields for the show chassis routing-engine command. Output
fields are listed in the approximate order in which they appear.
Table 384: show chassis routing-engine Output Fields
Field Name
Field Description
Temperature
Routing Engine temperature. (Not availabl... | Command introduced in Junos OS Release 9.5. | [] | |
show chassis routing-engine | show chassis routing-engine
<slot>
<bios>
<hard-disk-test> | Display the status of the Routing Engine. | [
{
"name": "none",
"desc": "Display information about one or more Routing Engines. On a TX Matrix router, display information about all Routing Engines on the TX Matrix router and its attached T640 routers. On a TX Matrix Plus router, display information about all Routing Engines on the TX Matrix Plus router... | view
Output Fields
Table 385 on page 19633 lists the output fields for the show chassis routing-engine command. Output
fields are listed in the approximate order in which they appear.
Table 385: show chassis routing-engine Output Fields
Field Name
Field Description
Slot
(Systems with single and multiple Routing Engines... | Command introduced before Junos OS Release 7.4.
5 sec CPU Utilization, 1 min CPU Utilization, 5 min CPU Utilization, and 15 min CPU Utilization output fields
introduced in Junos OS Release 11.3R1.
satellite option introduced in Junos OS Release 14.2R3.
humidity option introduced in Junos OS Release 25.4R1. | [
"request chassis routing-engine master",
"Configuring Routing Engine Redundancy",
"Switching the Global Primary and Backup Roles in a Virtual Chassis Configuration"
] | |
show chassis satellite extended-port | show chassis satellite extended-port interface-name
<fpc-slot fpc-slot>
<interface-name interface-name>
[brief | detail | extensive | terse]
<since time> | Display the status of the extended ports on the satellite devices in a Junos Fusion.
The extended ports are the network-facing ports on satellite devices that send and receive network
traffic for a Junos Fusion. | [
{
"name": "none",
"desc": "(Same as brief and terse) Display extended port status information."
},
{
"name": "brief | detail |",
"desc": ""
},
{
"name": "extensive | terse",
"desc": "(Optional) Display the specified level of output."
},
{
"name": "fpc fpc-slot",
"desc": "... | view
Output Fields
Table 386 on page 19648 lists the output fields for the show chassis satellite extended-port command.
Output fields are listed in the approximate order in which they appear.
Table 386: show chassis satellite extended-port Output Fields
Field Name
Field Description
Level of Output
Fields for Interface... | Command introduced in Junos OS Release 14.2R3. | [
"Configuring or Expanding a Junos Fusion Enterprise",
"Configuring Junos Fusion Provider Edge"
] | |
show chassis satellite interface | show chassis satellite interface
<interface-name>
[ brief | detail | extensive ]
<since time> | Display the status of the cascade ports as well as the internal satellite interfaces in a Junos Fusion.
You might see sd interfaces in the output of this command. These are internal interfaces for the Junos
Fusion. | [
{
"name": "interface-name",
"desc": "Specify the name of the interface."
},
{
"name": "none",
"desc": "(Same as brief) Display aggregation device interface information."
},
{
"name": "brief | detail |",
"desc": ""
},
{
"name": "extensive",
"desc": "(Optional) Display the ... | view
Output Fields
Table 387 on page 19653 lists the output fields for the show chassis satellite interface command. Output
fields are listed in the approximate order in which they appear.
Table 387: show chassis satellite interface Output Fields
Field Name
Field Description
Level of Output
Fields for Interface
Interfa... | Command introduced in Junos OS Release 14.2R3. | [
"Configuring or Expanding a Junos Fusion Enterprise",
"Configuring Junos Fusion Provider Edge"
] | |
show chassis satellite neighbor | show chassis satellite neighbor
[interface-name]
[ brief | detail | extensive | terse]
<since time> | A plain-text description of the hardware and
software currently running on the satellite
device.
brief
detail
extensive
Table 388: show chassis satellite neighbor Output Fields (Continued)
Field Name
Field Description
Level of Output
Build date
The date and time that the satellite software
was built.
brief
detail
exte... | [
{
"name": "interface-name",
"desc": "Specify the name of the cascade port on the aggregation device."
},
{
"name": "none",
"desc": "(Same as terse) Display satellite device connection information."
},
{
"name": "brief | detail |",
"desc": ""
},
{
"name": "extensive | terse",
... | view
Output Fields
Table 388 on page 19661 lists the output fields for the show chassis satellite neighbor command. Output
fields are listed in the approximate order in which they appear.
Table 388: show chassis satellite neighbor Output Fields
Field Name
Field Description
Level of Output
Fields for Interface
Interfac... | Command introduced in Junos OS Release 14.2R3. | [
"Configuring or Expanding a Junos Fusion Enterprise",
"Configuring Junos Fusion Provider Edge"
] | |
show chassis satellite power-budget-statistics | show chassis satellite power-budget-statistics
<slot-id slot-id-number> | Display the power budget statistics of a satellite device or devices in a Junos Fusion. | [
{
"name": "none",
"desc": "Display power budget statistics for all satellite devices in the Junos Fusion."
},
{
"name": "slot-id slot-id-number",
"desc": "Display power budget statistics for the specified satellite device only. The slot-id-number and the FPC ID are the same number in a Junos Fus... | view
Output Fields
Table 389 on page 19668 lists the output fields for the show chassis satellite-management power-budget-
statistics command. Output fields are listed in the approximate order in which they appear.
Table 389: show chassis satellite-management power-budget-statistics Output Fields
Field Name
Field Desc... | Command introduced in Junos OS Release 16.1R1. | [
"Understanding Power over Ethernet in a Junos Fusion"
] | |
show chassis satellite redundancy-group devices | show chassis satellite redundancy-group devices
[brief | detail | extensive | terse]
<history> | Display the status of the devices in a redundancy group in a Junos Fusion.
Redundancy groups are used in a Junos Fusion to configure, monitor, and maintain a topology using two
aggregation devices. | [
{
"name": "none",
"desc": "(Same as terse and brief) Display redundancy group device information for the Junos Fusion."
},
{
"name": "brief | detail | extensive |",
"desc": ""
},
{
"name": "terse",
"desc": "(Optional) Display the specified level of output."
},
{
"name": "hist... | view
Output Fields
Table 390 on page 19671 lists the output fields for the show chassis satellite redundancy-groups command.
Output fields are listed in the approximate order in which they appear.
Table 390: show chassis satellite redundancy-groups Output Fields
Field Name
Field Description
Level of Output
Cluster Name... | Command introduced in Junos OS Release 16.1R1. | [
"Configuring or Expanding a Junos Fusion Enterprise"
] | |
show chassis satellite redundancy-group | show chassis satellite redundancy-group
[brief | detail | extensive | terse]
<since time> | Display the status of the redundancy group in a Junos Fusion.
Redundancy groups are used in a Junos Fusion to configure, monitor, and maintain a topology using two
aggregation devices. | [
{
"name": "none",
"desc": "(Same as terse and brief) Display redundancy group information for the Junos Fusion."
},
{
"name": "brief | detail |",
"desc": ""
},
{
"name": "extensive |",
"desc": ""
},
{
"name": "terse",
"desc": "(Optional) Display the specified level of out... | view
Output Fields
Table 391 on page 19675 lists the output fields for the show chassis satellite redundancy-groups command.
Output fields are listed in the approximate order in which they appear.
Table 391: show chassis satellite redundancy-groups Output Fields
Field Name
Field Description
Level of Output
Name
The nam... | Command introduced in Junos OS Release 16.1R1. | [
"Configuring or Expanding a Junos Fusion Enterprise"
] | |
show chassis satellite software | show chassis satellite software
[ brief | detail ] | Display information related to the satellite software in the Junos Fusion. | [
{
"name": "none",
"desc": "(Same as brief) Display satellite device software information."
},
{
"name": "brief | detail",
"desc": "(Optional) Display the specified level of output."
}
] | view
Output Fields
Table 392 on page 19678 lists the output fields for the show chassis satellite neighbor command. Output
fields are listed in the approximate order in which they appear.
Table 392: show chassis satellite software Output Fields
Field Name
Field Description
Level of Output
Fields for Interface
Version
T... | Command introduced in Junos OS Release 14.2R3. | [
"Configuring or Expanding a Junos Fusion Enterprise",
"Configuring Junos Fusion Provider Edge"
] | |
show chassis satellite statistics | show chassis satellite statistics
<device-alias device-alias>
<fpc-slot fpc-slot>
<cluster cluster-name> | Display statistics for satellite devices in a Junos Fusion. | [
{
"name": "device-alias",
"desc": "Display output for the specified satellite device, which is identified by the device alias, only."
},
{
"name": "fpc-slot",
"desc": "Display output for the specified satellite device, which is identified by the FPC slot ID, only."
},
{
"name": "cluster-... | view
Output Fields
Table 393 on page 19682 lists the output fields for the show chassis satellite statistics command. Output
fields are listed in the approximate order in which they appear.
Table 393: show chassis satellite statistics Output Fields
Field Name
Field Description
Fields for Interface
Serial Number
The ser... | Command introduced in Junos OS Release 14.2R3. | [
"Configuring or Expanding a Junos Fusion Enterprise",
"Configuring Junos Fusion Provider Edge"
] | |
show chassis satellite unprovision | show chassis satellite unprovision
[brief | detail | extensive]
[cluster cluster-name]
<since time> | Display information about unprovisioned satellite devices in a Junos Fusion.
An unprovisioned satellite device in a Junos Fusion is a satellite device that is recognized by the
aggregation device, but is not participating in a Junos Fusion.
No output appears when this command is entered when a Junos Fusion contains no ... | [
{
"name": "none",
"desc": "(Same as brief) Display unprovisioned satellite device information."
},
{
"name": "brief | detail |",
"desc": ""
},
{
"name": "extensive",
"desc": "(Optional) Display the specified level of output."
},
{
"name": "cluster cluster-name",
"desc": "... | view
Output Fields
Table 394 on page 19690 lists the output fields for the show chassis satellite unprovision command.
Output fields are listed in the approximate order in which they appear.
Table 394: show chassis satellite unprovision Output Fields
Field Name
Field Description
Level of Output
System-Id
The MAC addres... | Command introduced in Junos OS Release 14.2R3. | [
"Configuring or Expanding a Junos Fusion Enterprise",
"Configuring Junos Fusion Provider Edge"
] | |
show chassis satellite upgrade-group | show chassis satellite upgrade-group
<upgrade-group-name>
[ brief | detail | extensive | terse] | Display information about the satellite software upgrade groups for the Junos Fusion.
A satellite software upgrade group is a group of satellite devices that are updated at the same time to
the same version of the satellite software. One Junos Fusion can contain multiple software upgrade
groups, and multiple software u... | [
{
"name": "none",
"desc": "(Same as brief and terse) Display satellite software upgrade group information for all satellite software upgrade groups."
},
{
"name": "brief | detail |",
"desc": ""
},
{
"name": "extensive | terse",
"desc": "(Optional) Display the specified level of outpu... | view
Output Fields
Table 395 on page 19697 lists the output fields for the show chassis satellite upgrade-group command.
Output fields are listed in the approximate order in which they appear.
Table 395: show chassis satellite upgrade-group Output Fields
Field Name
Field Description
Level of Output
Fields for Interface... | Command introduced in Junos OS Release 14.2R3. | [
"Configuring or Expanding a Junos Fusion Enterprise",
"Configuring Junos Fusion Provider Edge"
] | |
show chassis satellite | show chassis satellite
[device-alias device-alias | fpc-slot fpc-slot | cluster cluster-name]
[brief | detail | extensive | terse]
<since time> | Display the status of the satellite device connections in a Junos Fusion. | [
{
"name": "none",
"desc": "(Same as brief) Display satellite device connection information"
},
{
"name": "device-alias",
"desc": ""
},
{
"name": "device-alias",
"desc": "(Optional) Display satellite device connection information for the satellite device using the specified device ali... | view
Output Fields
Table 396 on page 19701 lists the output fields for the show chassis satellite command. Output fields are
listed in the approximate order in which they appear.
Table 396: show chassis satellite Output Fields
Field Name
Field Description
Level of Output
Fields for Interface
Table 396: show chassis sa... | Command introduced in Junos OS Release 14.2R3. | [
"Configuring or Expanding a Junos Fusion Enterprise",
"Configuring Junos Fusion Provider Edge"
] | |
show chassis satellite-cluster route | show chassis satellite-cluster route
[cluster cluster-name]
[fpc-slot slot-id] | Display information about the route to the aggregation device for a satellite device in a satellite device
cluster in a Junos Fusion. | [
{
"name": "cluster cluster-name",
"desc": "Display route information for all satellite devices in the specified cluster."
},
{
"name": "fpc-slot slot-id",
"desc": "Display route information for the satellite device using the specified FPC slot ID."
}
] | view
Output Fields
Table 397 on page 19717 lists the output fields for the show chassis satellite-cluster route command.
Output fields are listed in the approximate order in which they appear.
Table 397: show chassis satellite-cluster route Output Fields
Field Name
Field Description
Cluster Name
The name of the satelli... | Command introduced in Junos OS Release 16.1R1. | [
"Configuring or Expanding a Junos Fusion Enterprise"
] |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.