MACHINE_NO
stringclasses
48 values
ERROR_ID
int64
1
999
ERROR_CODE
stringclasses
245 values
ERROR_DESC
stringlengths
14
179
ERROR_CATEGORY1
stringclasses
11 values
SOLUTION
stringlengths
40
290
KM-ASSYM2-06
75
M7074
M7074-Z axis lower limit abnormality, far away from the origin end (X12), please check whether the slide table touches the limit
Electronic control abnormality
The solution to the M7074-Z axis lower limit abnormality error is to perform a thorough inspection of the slide table. Verify if the slide table is touching the lower limit and make any necessary adjustments or repairs to resolve the
KM-ASSYM2-06
76
M7075
M7075-Z axis return to origin time has timed out, please check whether the slide table is abnormal or stuck
Electronic control abnormality
To resolve the M7075 error where the Z axis return to origin has timed out, make sure to check the slide table abnormality or sticking condition. If it is normal, the problem may be with the encoder or the
KM-ASSYM2-06
81
M7080
M7080-Upper camera identification dispensing area detection failed
Visual abnormality
The M7080 error is related to the identification of the upper camera for dispensing area detection in Toshiba Smart MRI systems. This issue may arise due to camera misalignment, obstructions, or other technical problems.
KM-ASSYM2-06
83
M7082
M7082-MARK point recognition failed
Visual abnormality
The solution for the M7082-MARK point recognition failed error is to reset the device's memory and perform the point recognition process again. If the issue persists, it may be necessary to consult the device's manual or contact
KM-ASSYM2-06
84
M7083
M7083-PLC timed out waiting for the host computer to transmit the dispensing point position
Electronic control abnormality
The solution for the M7083-PLC timed out waiting for the host computer to transmit the dispensing point position error is to check the network communication between the SOPC unit and host computer, and ensure that the data transfer
KM-ASSYM2-06
85
M7084
M7084-Scan code gun scan code NG
Electronic control abnormality
The solution to the error M7084-Scan code gun scan code NG is to check the device's internal memory for corrupt files or a missing file system partition. If the issue persists, it may be necessary to perform a
KM-ASSYM2-06
86
M7085
M7085-TE replies card station Fail
Kazam exception
The M7085-TE replies card station fail error typically occurs when the replies card station fails to connect to the network or there is a problem with the network connection. The solution for this error may involve checking the network connection,
KM-ASSYM2-06
87
M7086
M7086-PLC timed out while waiting for the area identification completion signal from the host computer
Visual abnormality
The solution for the M7086-PLC timed out while waiting for the area identification completion signal from the host computer is to check the settings and configuration of the communication protocol between the PLC and the host computer. Make sure that
KM-ASSYM2-06
88
M7087
M7087-PLC timed out waiting for the host computer to send the scan code result
Machine communication abnormality
The solution for M7087-PLC error where the timed-out waiting for the host computer to send the scan code result involves verifying the host computer's network connection and IP address, updating the PLC's network
KM-ASSYM2-06
90
M7089
M7089-PLC timed out waiting for the host computer to transmit the weighing result
Machine communication abnormality
To resolve the M7089-PLC timeout error, connect the instrument network connection to the device network connection of the host computer and ensure that the weighing result is being transmitted to a valid device. This should resolve the issue and
KM-ASSYM2-06
91
M7090
M7090-The dispensing area detected by the upper camera is not within the range
Visual abnormality
M7090 errors usually occur when the printing head, the camera, or the paper tray is not in proper alignment. Before resolving the error, ensure that the paper tray is properly loaded, the camera is positioned correctly, and the printing
KM-ASSYM2-06
92
M7091
M7091-Scan code OK and receive TE Read signal timeout
Kazam exception
There could be various reasons why you are encountering the M7091-Scan code OK error along with TE Read signal timeout when scanning a code. Some possible solutions include updating your firmware, ensuring that your scanner is sufficiently powered
KM-ASSYM2-06
93
M7092
M7092-TE LINK out of range
Kazam exception
The solution for M7092-TE LINK out of range error depends on the context and the device in question. It can be resolved by adjusting the network settings, updating the firmware, or performing a hardware reset. In some
KM-ASSYM2-06
94
M7093
M7093-TE LINK timeout
Kazam exception
The M7093-TE link timeout error typically occurs when there is a problem with the connection between two devices. To resolve this issue, you will need to check the cable connections and ensure that they are secure. If the problem persists
KM-ASSYM2-06
95
M7094
M7094-The scan code of this site is OK, TE replies that the previous section has not passed the site or SFC failed to transmit data
Kazam exception
The solution to the error M7094 can be found by checking if the previous section of your scan has passed. If not, go to the previous section and repeat the scan. Alternatively, try to reset the SFC (Surface and
KM-ASSYM2-06
97
M7096
M7096-Weighing machine communication abnormality
Electronic control abnormality
The M7096 error on a weighing machine indicates communication abnormality. The solution may involve resetting the machine, checking for any software updates, or contacting the manufacturer for further assistance. This issue typically occurs when the machine cannot
KM-ASSYM2-06
98
M7097
M7097-The cylinder position of the glue barrel is abnormal
Organizational Abnormality
M7097 errors occur when the glue barrel's cylinder position is abnormal. To resolve this issue, you can try calibrating the glue barrel, checking for blockage in the cylinder, or performing a manual
KM-ASSYM2-06
99
M7098
M7098-The current position of the PCB board exceeds the safe distance, please check whether the PCB board is placed properly
Other exceptions
The error M7098 indicates that the PCB board is not placed properly. This issue can be resolved by rechecking the PCB board's position and ensuring that it is within the safe distance allowed for PCB placement. If
KM-ASSYM2-06
100
M7099
M7099-The current position of the PCB board is lower than the safe distance, please check whether the PCB board is placed properly
Other exceptions
The solution to M7099 error code is to check the placement of the PCB board in a safe distance, either by physically adjusting the board or fixing the position of the jig or fixture using the appropriate tools. It is crucial
KM-ASSYM2-06
102
M7101
M7101-Please clean the scale pan and press the "Scale Pan Easy Clean Button"
Abnormal personnel operation
The solution for the error M7101 is to clean the scale pan using a cleaning tool provided by the scale manufacturer, and then to press the "Scale Pan Easy Clean Button" to reset the scale. If the problem persists, the
KM-ASSYM2-06
103
M7102
M7102-Weighing machine reset failed
Electronic control abnormality
M7102-Weighing machine reset failed error typically occurs when the machine cannot initialize due to an incorrect password or issue with its software. To resolve this, consult the owner manual for instructions on resetting the machine and updating its firm
KM-ASSYM2-06
89
M7088
M7088-PLC timed out waiting for the signal from the host computer to complete the electronic scale clearing
Visual abnormality
The problem M7088-PLC timed out waiting for the signal from the host computer to complete the electronic scale clearing could be caused by a lack of a consistent connection between the PLC and the host computer. The solution may involve
KM-ASSYM2-06
96
M7095
M7095-The host computer did not read the READ signal sent by TE, LINK fail
Kazam exception
If you encounter the M7095 error message ("The host computer did not read the READ signal sent by TE, LINK fail"), it often indicates a problem with the network adapter or the cable connection. First, make sure that the cable
KM-ASSYM2-06
101
M7100
M7100-When starting the machine, please clean the scale pan first and click the Cleared button before starting the machine.
Abnormal personnel operation
The solution to the M7100 error when starting the machine is to clean the scale pan and click the Cleared button before starting the machine. This will ensure that the scale is accurate and ready for use.
KM-ASSYM2-06
117
M7116
M7116-Timeout waiting for next action
Machine communication abnormality
The M7116-Timeout waiting for next action error typically occurs when a software process is awaiting user input or a system event but is not receiving it within a specified timeout period. The solution may involve increasing the timeout limit, optimizing
KM-ASSYM2-06
67
M7066
M7066-X axis left limit is abnormal, far away from the origin end (X6), please check whether the slide table touches the limit
Electronic control abnormality
The M7066 error denotes that the left limit of the X axis is abnormal and far away from the origin end (X6). Checking whether the slide table touches the limit is recommended to solve this issue.
KM-ASSYM2-06
113
M7112
M7112-Visual software model number is inconsistent with PLC model number
Visual abnormality
The solution to the M7112 error is to check that the visual software model number matches the PLC model number. If both numbers are correct, then the error may be caused by a mismatch between the cable connections, power supply,
KM-ASSYM2-06
114
M7113
M7113-Current discharging point index is out of range
Visual abnormality
The solution to the M7113 error involves updating the current discharging point settings on the device in question to within the specified range. This can typically be done through the device's user manual or settings interface. If the issue pers
KM-ASSYM2-06
115
M7114
M7114-Timeout waiting for dispensing result
Visual abnormality
The M7114-Timeout waiting for dispensing result error typically occurs when the system is unable to complete a dispensing operation within a specified time limit. The solution may involve troubleshooting the hardware or software, adjusting the time
KM-ASSYM2-06
116
M7115
M7115-The discharge point exceeds the index range
Visual abnormality
The error "M7115-The discharge point exceeds the index range" indicates a problem in the discharge of stored procedures. To resolve this issue, you can check the discharge point value and modify it within the index range
KM-ASSYM2-06
118
M7117
M7117-The number of required assemblies is more than the number of positioned cameras
Other exceptions
The M7117 error occurs when the number of required assemblies exceeds the number of positioned cameras in a camera-based manufacturing process. To resolve this issue, you can either increase the number of positioned cameras or optimize the assembly
KM-ASSYM2-06
120
M7119
M7119-CMC responded with incorrect material number confirmation information
Abnormal personnel operation
The solution for M7119-CMC responding with incorrect material number confirmation information is to review and double-check the material number being entered, ensure it follows the correct format, and try resetting the device or running material verification checks.
KM-ASSYM2-06
121
M7120
M7120-The function of confirming the material number of the host computer CMC has been blocked
Other exceptions
To resolve M7120 error, ensure that the host computer CMC is functioning properly and has the necessary permissions to access the material number confirmation function. You may also need to update the system or application software to the latest version. If the
KM-ASSYM2-06
1
M7000
M7000-Thermal paste is about to run out, please prepare thermal paste
Abnormal personnel operation
This error message usually appears on a printer to notify the user that the thermal paste is running out and the user needs to replace it before the printer will continue to function properly. The printer uses thermal paste to help maintain a consistent temperature of the printer head
KM-ASSYM2-06
2
M7001
M7001-Start detecting that there is material in the work area, please select the work area status
Abnormal personnel operation
The solution for the error "M7001-Start detecting that there is material in the work area, please select the work area status?" is to ensure that the appropriate work area is selected before starting the processing by either re-routing
KM-ASSYM2-06
17
M7016
M7016-EMO&&DOOR is on. Please check the safety door and emergency stop switch (X22)
Abnormal personnel operation
The solution for the error described as M7016-EMO&&DOOR is on, is to check the safety door and emergency stop switch (X22). If either of these components is faulty, it can cause the error
KM-ASSYM2-06
18
M7017
M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
The solution for the M7017-Equipment model setting is abnormal error is to check for invalid or missing values in the model settings, and to update the model accordingly. Additionally, ensure that the equipment model being used is a
KM-ASSYM2-06
19
M7018
M7018-The automatic process is not reset before starting, please press the reset button first
Abnormal personnel operation
The solution to the M7018 error is to press the reset button first before attempting to start the automatic process. Once the reset is complete, the process should restart without any issues.
KM-ASSYM2-06
20
M7019
M7019-The device abnormality has not been eliminated before automatic startup. Please eliminate the device abnormality first
Abnormal personnel operation
The solution for M7019 error is to first identify and eliminate the device abnormality before automatic startup. This can be achieved through manually testing the device and resetting it if necessary.
KM-ASSYM2-06
21
M7020
M7020-The equipment slide table has not returned to the origin, please execute the slide table return to the origin first
Abnormal personnel operation
The solution for the M7020 error is to execute the slide table return to the origin first before attempting any other operation on the equipment.
KM-ASSYM2-06
33
M7032
M7032-The feeding operation of the front Buffer conveyor belt times out, please check whether there is any jamming between the upper and lower reaches of the machine
Organizational Abnormality
The error M7032 indicates that the feeding operation of the front buffer conveyor belt has timed out, which may be due to jamming between the upper and lower reaches of the machine. The solution to this issue is to check for
KM-ASSYM2-06
34
M7033
M7033-The discharging operation of the front buffer conveyor belt times out, please check whether the machine is jammed
Organizational Abnormality
The M7033 error message indicates that the front buffer conveyor belt is experiencing a discharging operation timeout. This occurs when the machine is jammed and prevents it from releasing its contents. To resolve this issue, please inspect the belt
KM-ASSYM2-06
70
M7069
M7069-Y axis front limit is abnormal, close to the origin end (X11), please check whether the slide table touches the limit
Electronic control abnormality
The solution for M7069-Y axis front limit is abnormal, close to the origin end (X11) is to check whether the slide table touches the limit. The problem could be caused by the slide table moving too far
KM-ASSYM2-06
74
M7073
M7073-The limit on the Z axis is abnormal, close to the origin end (X13), please check whether the slide table touches the limit
Electronic control abnormality
The solution to M7073 error that states the limit on the Z axis is abnormal, close to the origin end (X13) is to check whether the slide table touches the limit. This can be accomplished by physically inspecting
KM-ASSYM2-06
82
M7081
M7081-PLC timed out waiting for the host computer to transmit the MARK point identification signal
Visual abnormality
The M7081-PLC timed out waiting for the host computer to transmit the MARK point identification signal error usually occurs when the PLC is unable to receive or interpret the signal from the host computer within the specified time limit.
KM-ASSYM2-06
119
M7118
M7118-CMC reply material number confirmation message timeout (10S)
Machine communication abnormality
The solution for the error M7118-CMC reply material number confirmation message timeout is to increase the timeout period to 10 seconds or set it to an appropriate value based on the system's requirements. Alternatively, checking the
KM-ASSYM2-07
6
M75
M75-Start detecting that there is material in the work area, please select the work area status
Abnormal personnel operation
The solution for the M75-Start error is to select the work area status as "Clear" before starting the machine. If the work area is not clear, the machine will not start and will display this error message.
KM-ASSYM2-07
11
M80
M80-EMO&&DOOR is on. Please check the safety door and emergency stop switch (X14)
Abnormal personnel operation
The solution for the error M80-EMO&&DOOR is on. Please check the safety door and emergency stop switch (X14) involves resetting the emergency stop button and ensuring that the safety door is closed before starting the machine
KM-ASSYM2-07
12
M81
M81-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
To resolve the error M81-Equipment model setting is abnormal, please set the model, follow these steps: 1. Identify the equipment in question. 2. Determine the correct model number for the equipment.
KM-ASSYM2-07
13
M82
M82-Please press the reset button before starting the automatic process
Abnormal personnel operation
The solution to the M82 error described as "Please press the reset button before starting the automatic process" is to press the reset button and then restart the device or application that is producing the error. This will often clear any corrupted files or
KM-ASSYM2-07
14
M83
M83-The device has not returned to the origin, please execute the device to return to the origin first
Abnormal personnel operation
The solution to the M83 error is to perform a device initialization or power cycle by turning off the radio and then back on to reset the device's location and return it to its starting point.
KM-ASSYM2-08
1
M70
M70-The labeling machine is out of material
Abnormal personnel operation
The solution to the M70 error, "The labeling machine is out of material," can be resolved by either restocking the labeling machine with the appropriate labeling materials or by using a different labeling machine with an adequate supply of
KM-ASSYM2-08
2
M71
M71-The discharging operation of the labeling machine has timed out. Please check whether the labeling machine is short of material or stuck
Electronic control abnormality
The solution for the M71 error is to check if the labeling machine is out of material or stuck. If it is, reload the machine with fresh label stock or troubleshoot any mechanical issues that may be preventing the machine from functioning
KM-ASSYM2-08
11
M80
M80-EMO&&DOOR is on. Please check the safety door and emergency stop switch (X6)
Abnormal personnel operation
The solution for the error M80-EMO&&DOOR is on. Please check the safety door and emergency stop switch (X6) is to verify that the safety door is closed and the emergency stop switch is disabled before starting the machine
KM-ASSYM2-08
12
M81
M81-Equipment model setting has not been set, please set the device model
Abnormal personnel operation
The solution for the error "M81-Equipment model setting has not been set, please set the device model" is to open the device manager, identify the problematic device, right-click and select "Properties," then click on
KM-ASSYM2-08
13
M82
M82-The automatic process has not been reset before starting, please press the reset button first
Abnormal personnel operation
The solution for this error is to reset the automatic process, press the reset button, and then start the process again.
KM-ASSYM2-08
14
M83
M83-The equipment Robot has not returned to the origin, please execute the equipment return to the origin first
Abnormal personnel operation
If equipment is not at the origin, the solution is to execute the equipment return to the origin first before conducting further tasks or operations. This will ensure that all equipment is accounted for and available when needed. It is important to ensure that all equipment
KM-ASSYM2-08
18
M87
M87-The feeding operation of the front waiting area has timed out, please check whether the board is stuck between the upstream and downstream of the machine
Organizational Abnormality
The solution to the error M87 is to check the board to see if it is stuck between the upstream and downstream of the machine. This usually occurs when a machine is stopped, and the conveyor belt stops, causing the downstream
KM-ASSYM2-08
19
M88
M88-The discharging operation of the front waiting area has timed out, please check whether the machine is stuck
Organizational Abnormality
The solution for M88 error is to check whether the machine is stuck by resetting the waiting queue or contacting technical support for further assistance.
KM-ASSYM2-08
20
M89
M89-The material feeding operation in the work area has timed out, please check whether the machine is jammed
Organizational Abnormality
The solution for the M89 error is to open the work area and check for any jammed material or blockage. If there is no jam, perform a restart of the machine while observing the material feed operation. If the error repeats
KM-ASSYM2-08
21
M90
M90-The discharging operation in the work area has timed out, please check whether there is any jamming between the upstream and downstream of the machine
Organizational Abnormality
The solution for the M90 error is to check for any jamming between the upstream and downstream of the machine. If there is jamming, it should be cleared before attempting the discharging operation again. If no jamming is
KM-ASSYM2-08
25
M94
M94-The jacking cylinder in the work area rises abnormally (X24), please check whether the cylinder is stuck when rising
Organizational Abnormality
The solution for M94 error is to investigate whether the jacking cylinder is stuck during its rise. To do this, the operator needs to verify whether the cylinder is free to move and if it's rising smoothly. If the cyl
KM-ASSYM2-08
26
M95
M95-The lifting cylinder in the work area is abnormally descending (X25), please check whether the cylinder is stuck when descending
Organizational Abnormality
The solution to the M95 error "The lifting cylinder in the work area is abnormally descending (X25), please check whether the cylinder is stuck when descending" is to check if the cylinder is stuck during
KM-ASSYM2-08
27
M96
M96-The work area blocking cylinder is rising abnormally (X26), please check whether the cylinder is stuck when rising
Organizational Abnormality
Check if the cylinder is stuck when rising. If the movement is restricted and the cylinder cannot fully extend, then the error M96-The work area blocking cylinder is rising abnormally (X26) may be caused by
KM-ASSYM2-08
28
M97
M97-The work area blocking cylinder is abnormally descending (X27), please check whether the cylinder is stuck when descending
Organizational Abnormality
The solution for M97 error with X27 is to confirm whether the cylinder is stuck while descending. The work area blocking cylinder could be descending abnormally due to several reasons, such as mechanical, electrical, or software
KM-ASSYM2-08
38
M107
M107-Robot has an abnormal alarm, please use Robot to eliminate the abnormality first
Electronic control abnormality
The solution to the M107-Robot error is to use the Robot tool to eliminate the abnormality that triggered the alarm. This can be done by identifying and correcting the cause of the abnormality, such as a
KM-ASSYM2-08
39
M108
M108-Assembly point deviation is too large
Electronic control abnormality
The M108-Assembly point deviation is too large error typically occurs in assembly code when attempting to perform a modification that exceeds the amount of memory available. To fix this issue, you may need to adjust the code to allocate less memory
KM-ASSYM2-08
41
M110
M110-single assembly less than 12 pieces
Other exceptions
The M110 error occurs when the number of assemblies being built falls below 12 pieces. Increase the number of assemblies through the project settings, or add additional assemblies to the project. If none of these
KM-ASSYM2-08
42
M111
The M111-MAKE point deviation is too large, please check whether the PCB board is abnormal
Visual abnormality
The solution for the error described as The M111-MAKE point deviation is too large is to check whether the PCB board is abnormal by verifying its design, layout, and connection. If the board is found to be
KM-ASSYM2-08
43
M112
M112-Make point photo failed, please check whether the PCB board is abnormal
Visual abnormality
The solution for the error "M112-Make point photo failed" is to check whether the PCB board is damaged or abnormal. This issue can be fixed by correcting the PCB design or board configuration, ensuring the board is
KM-ASSYM2-08
44
M113
M113-The left nozzle failed to pick up material for 3 consecutive times. Please check whether the Feeder discharging position is correct & whether the material belt is stuck
Electronic control abnormality
The solution for M113 error involves checking whether the Feeder discharging position is correct and if the material belt is stuck. If the feeder is not discharging material, adjust the discharge position. If the belt is stuck
KM-ASSYM2-08
45
M114
M114-The right nozzle failed to pick up material for 3 consecutive times. Please check whether the Feeder discharging position is correct & whether the material belt is stuck
Electronic control abnormality
The solution for the error M114 is to check the feeder discharging position and whether the material belt is stuck. If the feeder is discharging in the wrong position or the belt is stuck, the nozzle will
KM-ASSYM2-08
46
M115
M115-The left nozzle failed to detect 3 consecutive times at the lower camera. Please check whether the incoming material is abnormal
Electronic control abnormality
The solution for M115-The left nozzle failed to detect 3 consecutive times at the lower camera is likely due to a blockage in the material flow. To fix this issue, the lower camera needs to be inspected and
KM-ASSYM2-08
47
M116
M116-The right nozzle failed to detect 3 consecutive times at the lower camera. Please check whether the incoming material is abnormal
Visual abnormality
The solution to M116 errors is typically to check for any incoming material abnormalities that may be causing the nozzle to detect a problem. Any material that is too hard, too sticky, or too abrasive can affect
KM-ASSYM2-08
51
M120
M120-Camera connection failed, please reconnect the camera
Visual abnormality
The solution to the M120-Camera connection failed error is to reconnect your camera to your computer or to the app you are using and restart the camera and app. If the issue persists, it may be necessary to update the camera
KM-ASSYM2-08
52
M121
The connection between M121-Robot and CCD failed, please check the communication connection or network cable between Robot and CCD
Electronic control abnormality
The solution for the error "The connection between M121-Robot and CCD failed" would be to verify and check the communication connection or network cable between the Robot and CCD to ensure it is properly connected and functioning.
KM-ASSYM2-08
54
M123
M123-CCD failed to send signal to arm
Visual abnormality
The solution for the error described as M123-CCD failed to send signal to arm may vary depending on the specific cause of the issue. It is recommended to consult the manual or contact the manufacturer for further assistance. Possible solutions include
KM-ASSYM2-08
55
M124
M124-CCD failed to send READY signal to the arm
Visual abnormality
This error usually indicates a hardware issue with the CCD camera controller in your robot arm. It may require updating or reprogramming the controller's firmware or software, or troubleshooting the controller's connections to ensure the arm receives
KM-ASSYM2-08
56
M125
M125-CCD failed to send START signal to the arm
Visual abnormality
The error message "M125-CCD failed to send start signal to the arm" occurs when the CCD (charge-coupled device) sensor sends an incorrect signal to the robotic arm, impeding its movement. To resolve
KM-ASSYM2-08
57
M126
M126-CCD failed to send CHECK signal to the arm
Visual abnormality
First check the sensor fusion and CCD system logs for any errors or warnings related to the M126-CCD check signal issue. If the issue persists, you may need to replace the CCD or perform firmware updates to resolve
KM-ASSYM2-08
58
M127
M127-CCD failed to send the MAKE signal to the arm
Visual abnormality
To diagnose the M127-CCD error, you should check if there is any loose wire or connection issue on the MAKE sensor. You can also reset the CCD device or update the firmware if needed. Replace/
KM-ASSYM2-08
60
M129
M129-CCD failed to send the material picking test result signal to the arm
Visual abnormality
The solution for the error "M129-CCD failed to send the material picking test result signal to the arm" may involve troubleshooting the communication between the CCD and the arm. It may also involve resetting or re
KM-ASSYM2-08
61
M130
M130-CCD failed to send the camera detection result to the arm
Visual abnormality
The solution to the M130-CCD error is to ensure that the camera is properly connected and functioning, that the communication settings are correct, and that the software is up-to-date. If the issue persists, adjusting
KM-ASSYM2-08
62
M131
M131-CCD failed to send the assembly point to the arm
Visual abnormality
The solution for the M131-CCD error is to ensure that the arm architecture of your computer matches the one expected by the program. You may need to update your compiler or change your code to use the correct syntax for your architecture.
KM-ASSYM2-08
64
M133
M133-CCD timed out waiting for arm READY OK signal
Machine communication abnormality
The solution for the M133-CCD timed out waiting for arm READY OK signal error can be obtained by either adjusting the communication timeouts and retries or using a different communication protocol to establish contact with the CCD device
KM-ASSYM2-08
65
M134
M134-CCD timed out waiting for arm START OK signal
Machine communication abnormality
The M134-CCD error occurs when the Arduino attempts to communicate with the CCD module over the serial port, but the module does not respond within a specified time period. This error can be resolved by adjusting the b
KM-ASSYM2-08
66
M135
M135-CCD timed out waiting for arm Check point in place signal
Machine communication abnormality
The M135-CCD timed out waiting for arm check point in place signal error is typically caused by a configuration issue or hardware failure in Rigid Infrastructure Monitoring (RIGM) hardware. To resolve this error,
KM-ASSYM2-08
67
M136
M136-CCD reading arm Arrive signal timed out
Visual abnormality
To fix the M136-CCD reading arm "Arrive signal timed out" error, you can try adjusting the timing settings of the reading arm, resetting the communication between devices, or checking for any possible interference with other
KM-ASSYM2-08
115
M7000
M7000-Manual/Automatic Switching
Other exceptions
The solution for M7000-Manual/Automatic Switching Error depends on the specific error message and circumstances. Resetting the switch or modem may fix the issue, while updating firmware or contacting technical support may also resolve
KM-ASSYM2-08
116
M7001
M7001-Device starting
Other exceptions
The solution for the error M7001-Device Starting may vary depending on the device and operating system, but usually involves resetting the device or performing a firmware update. It's recommended to consult the device's user manual or
KM-ASSYM2-08
117
M7002
M7002-Equipment is stopping
Other exceptions
The solution for an equipment error described as M7002-Equipment is stopping may require disassembling and resetting the system, updating firmware or drivers, contacting equipment manufacturer support for assistance, or resolving any hardware issues
KM-ASSYM2-08
118
M7003
M7003-Device in standby
Other exceptions
M7003-Device in standby typically occurs when the device, such as a wireless router or bridge, has been powered off for an extended period or is experiencing connectivity issues. To troubleshoot this error, first ensure that the
KM-ASSYM2-08
119
M7004
M7004-Equipment alarming
Other exceptions
The solution for M7004-Equipment alarming error would depend on the specific piece of equipment and issue causing it. It could be resolved by performing maintenance or repairs, checking connections or sensors, resetting parameters, or updating software
KM-ASSYM2-08
120
M7005
M7005-Pass function is enabled
Abnormal personnel operation
M7005 error means that the Pass function is enabled in your Excel spreadsheet. To fix this error, you need to disable the Pass function by going to the "Worksheet" tab and clicking on "Properties". In the "
KM-ASSYM2-08
59
M128
M128-CCD failed to send command to arm
Visual abnormality
The solution for the error described as M128-CCD failed to send command to ARM is to check the connection between the CCD camera and the ARM control unit. If the connection is loose or damaged, tighten it or replace it
KM-ASSYM2-08
63
M132
M132-CCD failed to send the completion signal to the arm
Visual abnormality
The error you described is likely related to a communication problem between the M132-CCD and the arm. This issue could be caused by a faulty cable, a malfunctioning device, or incorrect settings. To resolve this issue,
KM-ASSYM2-08
53
M122
No feedback within 30s from communication between M122-CCD and arm
Visual abnormality
The solution to the error "No feedback within 30s from communication between M122-CCD and arm" could involve checking for faulty hardware or software connections, ensuring that the correct communication protocol is being used, and making sure
LINK
18
M7017
M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
The solution for the M7017-Equipment model setting is abnormal error is to check for invalid or missing values in the model settings, and to update the model accordingly. Additionally, ensure that the equipment model being used is a
KM-ASSYM3-03
1
M70
M70-The labeling machine is out of material
Abnormal personnel operation
The solution to the M70 error, "The labeling machine is out of material," can be resolved by either restocking the labeling machine with the appropriate labeling materials or by using a different labeling machine with an adequate supply of
KM-ASSYM3-03
2
M71
M71-The discharging operation of the labeling machine has timed out. Please check whether the labeling machine is short of material or stuck
Electronic control abnormality
The solution for the M71 error is to check if the labeling machine is out of material or stuck. If it is, reload the machine with fresh label stock or troubleshoot any mechanical issues that may be preventing the machine from functioning