MACHINE_NO
stringclasses
48 values
ERROR_ID
int64
1
999
ERROR_CODE
stringclasses
245 values
ERROR_DESC
stringlengths
14
179
ERROR_CATEGORY1
stringclasses
11 values
SOLUTION
stringlengths
40
290
KM-ASSYM1-07
33
M7045
Alarm: initial startup, there is material in the assembly line
Abnormal personnel operation
To fix the error described as Alarm: initial startup, there is material in the assembly line, you'll need to identify the source of the material and clear it from the assembly line. This may require adjusting your manufacturing processes or stopping production
KM-ASSYM2-01
89
M7088
M7088-PLC timed out waiting for the signal from the host computer to complete the electronic scale clearing
Visual abnormality
The problem M7088-PLC timed out waiting for the signal from the host computer to complete the electronic scale clearing could be caused by a lack of a consistent connection between the PLC and the host computer. The solution may involve
KM-ASSYM2-01
96
M7095
M7095-The host computer did not read the READ signal sent by TE, LINK fail
Kazam exception
If you encounter the M7095 error message ("The host computer did not read the READ signal sent by TE, LINK fail"), it often indicates a problem with the network adapter or the cable connection. First, make sure that the cable
KM-ASSYM2-01
101
M7100
M7100-When starting the machine, please clean the scale pan first and click the Cleared button before starting the machine.
Abnormal personnel operation
The solution to the M7100 error when starting the machine is to clean the scale pan and click the Cleared button before starting the machine. This will ensure that the scale is accurate and ready for use.
KM-ASSYM2-01
118
M7117
M7117-The number of required assemblies is more than the number of positioned cameras
Other exceptions
The M7117 error occurs when the number of required assemblies exceeds the number of positioned cameras in a camera-based manufacturing process. To resolve this issue, you can either increase the number of positioned cameras or optimize the assembly
KM-ASSYM2-01
66
M7065
M7065-The right limit of the X-axis is abnormal, close to the origin end (X7), please check whether the slide table touches the limit
Electronic control abnormality
The solution for the M7065 error is to check if the slide table is touching the limit at the origin end (X7) and increase the left limit value if necessary to prevent the issue.
KM-ASSYM2-01
1
M7000
M7000-Thermal paste is about to run out, please prepare thermal paste
Abnormal personnel operation
This error message usually appears on a printer to notify the user that the thermal paste is running out and the user needs to replace it before the printer will continue to function properly. The printer uses thermal paste to help maintain a consistent temperature of the printer head
KM-ASSYM2-01
18
M7017
M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
The solution for the M7017-Equipment model setting is abnormal error is to check for invalid or missing values in the model settings, and to update the model accordingly. Additionally, ensure that the equipment model being used is a
KM-ASSYM2-01
2
M7001
M7001-Start detecting that there is material in the work area, please select the work area status
Abnormal personnel operation
The solution for the error "M7001-Start detecting that there is material in the work area, please select the work area status?" is to ensure that the appropriate work area is selected before starting the processing by either re-routing
KM-ASSYM2-01
17
M7016
M7016-EMO&&DOOR is on. Please check the safety door and emergency stop switch (X22)
Abnormal personnel operation
The solution for the error described as M7016-EMO&&DOOR is on, is to check the safety door and emergency stop switch (X22). If either of these components is faulty, it can cause the error
KM-ASSYM2-01
19
M7018
M7018-The automatic process is not reset before starting, please press the reset button first
Abnormal personnel operation
The solution to the M7018 error is to press the reset button first before attempting to start the automatic process. Once the reset is complete, the process should restart without any issues.
KM-ASSYM2-01
20
M7019
M7019-The device abnormality has not been eliminated before automatic startup. Please eliminate the device abnormality first
Abnormal personnel operation
The solution for M7019 error is to first identify and eliminate the device abnormality before automatic startup. This can be achieved through manually testing the device and resetting it if necessary.
KM-ASSYM2-01
33
M7032
M7032-The feeding operation of the front Buffer conveyor belt times out, please check whether there is any jamming between the upper and lower reaches of the machine
Organizational Abnormality
The error M7032 indicates that the feeding operation of the front buffer conveyor belt has timed out, which may be due to jamming between the upper and lower reaches of the machine. The solution to this issue is to check for
KM-ASSYM2-01
34
M7033
M7033-The discharging operation of the front buffer conveyor belt times out, please check whether the machine is jammed
Organizational Abnormality
The M7033 error message indicates that the front buffer conveyor belt is experiencing a discharging operation timeout. This occurs when the machine is jammed and prevents it from releasing its contents. To resolve this issue, please inspect the belt
KM-ASSYM2-01
36
M7035
M7035-The discharge conveyor belt in the work area has run timeout, please check whether the machine is jammed
Organizational Abnormality
The solution for M7035 error is to manually check if the discharge conveyor belt is jammed by inspecting the belt and clearing any obstacles or debris. If the problem persists, it may require maintenance or repair of the
KM-ASSYM2-01
37
M7036
M7036-The feeding operation of the rear buffer conveyor belt has timed out, please check whether the machine is jammed
Organizational Abnormality
The solution for the M7036 error is to check the rear buffer conveyor belt for jams or obstructions. If the belt is jammed, clear the obstruction and try running the belt again. If the belt continues to jam
KM-ASSYM2-01
39
M7038
M7038-The work area blocking cylinder is rising abnormally (X33), please check whether the cylinder is stuck when rising
Organizational Abnormality
The solution for the error M7038-The work area blocking cylinder is rising abnormally (X33) is to check whether the cylinder is stuck when rising. If it is, the cylinder may need to be
KM-ASSYM2-01
40
M7039
M7039-The work area blocking cylinder is abnormally descending (X34), please check whether the cylinder is stuck when descending
Organizational Abnormality
The solution for the M7039 error is to manually lower the cylinder and verify that it moves freely. If the cylinder only moves when lowered, it may be stuck and the maintenance team should be consulted for further investigation and repair
KM-ASSYM2-01
41
M7040
M7040-The jacking cylinder in the work area rises abnormally (X31), please check whether the cylinder is stuck when rising
Organizational Abnormality
There are several possible reasons for M7040-The jacking cylinder in the work area rises abnormally. One cause could be a stuck cylinder, which could be due to pressure buildup or debris blocking the cylinder
KM-ASSYM2-01
44
M7043
M7043-Conveyor belt width adjustment cylinder retracts abnormally (X30), please check whether the cylinder is stuck when descending
Organizational Abnormality
The solution for M7043 errors related to the conveyor belt width adjustment cylinder retracting abnormally (X30) involves checking whether the cylinder is stuck during descent. This issue can cause damage to the convey
KM-ASSYM2-01
54
M7053
M7053-The current glue amount is too much, please reduce it
Electronic control abnormality
Reduce the current glue amount by using less adhesive, replacing damaged parts, or adjusting the bonding process to ensure proper adhesion. In some cases, the use of a different type of adhesive or solvent may
KM-ASSYM2-01
55
M7054
M7054-The current dispensing amount is too small, please increase
Electronic control abnormality
The error M7054 usually occurs when the dispensing amount is less than the minimum amount required. To solve this error, you need to increase the dispensing amount by adjusting the settings on your printer or using a different ink cartr
KM-ASSYM2-01
65
M7064
M7064-X-axis servo NO readly(X14)&ERROR, please check whether the X-axis servo driver is abnormal
Electronic control abnormality
The solution to the M7064-X-axis servo NO readly(X14)&ERROR error is to check the abnormality of the X-axis servo driver. You can do this by examining the logs
KM-ASSYM2-01
68
M7067
M7067-X axis return to origin time has timed out, please check whether the slide table is abnormal or stuck
Electronic control abnormality
The error M7067 typically occurs when the X-axis slide table times out during its return to origin movement. This could be due to a malfunctioning actuator, a stuck slide table, or a problem with the home position
KM-ASSYM2-01
69
M7068
M7068-Y-axis servo NO readly(X15)&ERROR, please check whether the X-axis servo driver is abnormal
Electronic control abnormality
The error M7068-Y-axis servo NO readly(X15)&ERROR usually indicates that there is a failure in the communication between the X-axis servo driver and the printer. To solve the problem, it
KM-ASSYM2-01
72
M7071
M7071-Y axis return to origin time has timed out, please check whether the slide table is abnormal or stuck
Electronic control abnormality
The M7071-Y axis return to origin time has timed out error indicates that the Y-axis slide table is not responding to commands. This can be due to a stuck or abnormal condition. To troubleshoot this issue
KM-ASSYM2-01
73
M7072
M7072-Z-axis servo NO readly(X16)&ERROR, please check whether the Z-axis servo driver is abnormal
Electronic control abnormality
The error M7072-Z-axis servo NO ready(X16)&ERROR suggests that there might be an issue with the Z-axis servo driver. The solution for this issue is to check the Z-axis serv
KM-ASSYM2-01
74
M7073
M7073-The limit on the Z axis is abnormal, close to the origin end (X13), please check whether the slide table touches the limit
Electronic control abnormality
The solution to M7073 error that states the limit on the Z axis is abnormal, close to the origin end (X13) is to check whether the slide table touches the limit. This can be accomplished by physically inspecting
KM-ASSYM2-01
75
M7074
M7074-Z axis lower limit abnormality, far away from the origin end (X12), please check whether the slide table touches the limit
Electronic control abnormality
The solution to the M7074-Z axis lower limit abnormality error is to perform a thorough inspection of the slide table. Verify if the slide table is touching the lower limit and make any necessary adjustments or repairs to resolve the
KM-ASSYM2-01
76
M7075
M7075-Z axis return to origin time has timed out, please check whether the slide table is abnormal or stuck
Electronic control abnormality
To resolve the M7075 error where the Z axis return to origin has timed out, make sure to check the slide table abnormality or sticking condition. If it is normal, the problem may be with the encoder or the
KM-ASSYM2-01
81
M7080
M7080-Upper camera identification dispensing area detection failed
Visual abnormality
The M7080 error is related to the identification of the upper camera for dispensing area detection in Toshiba Smart MRI systems. This issue may arise due to camera misalignment, obstructions, or other technical problems.
KM-ASSYM2-01
83
M7082
M7082-MARK point recognition failed
Visual abnormality
The solution for the M7082-MARK point recognition failed error is to reset the device's memory and perform the point recognition process again. If the issue persists, it may be necessary to consult the device's manual or contact
KM-ASSYM2-01
84
M7083
M7083-PLC timed out waiting for the host computer to transmit the dispensing point position
Electronic control abnormality
The solution for the M7083-PLC timed out waiting for the host computer to transmit the dispensing point position error is to check the network communication between the SOPC unit and host computer, and ensure that the data transfer
KM-ASSYM2-01
85
M7084
M7084-Scan code gun scan code NG
Electronic control abnormality
The solution to the error M7084-Scan code gun scan code NG is to check the device's internal memory for corrupt files or a missing file system partition. If the issue persists, it may be necessary to perform a
KM-ASSYM2-01
86
M7085
M7085-TE replies card station Fail
Kazam exception
The M7085-TE replies card station fail error typically occurs when the replies card station fails to connect to the network or there is a problem with the network connection. The solution for this error may involve checking the network connection,
KM-ASSYM2-01
87
M7086
M7086-PLC timed out while waiting for the area identification completion signal from the host computer
Visual abnormality
The solution for the M7086-PLC timed out while waiting for the area identification completion signal from the host computer is to check the settings and configuration of the communication protocol between the PLC and the host computer. Make sure that
KM-ASSYM2-01
88
M7087
M7087-PLC timed out waiting for the host computer to send the scan code result
Machine communication abnormality
The solution for M7087-PLC error where the timed-out waiting for the host computer to send the scan code result involves verifying the host computer's network connection and IP address, updating the PLC's network
KM-ASSYM2-01
90
M7089
M7089-PLC timed out waiting for the host computer to transmit the weighing result
Machine communication abnormality
To resolve the M7089-PLC timeout error, connect the instrument network connection to the device network connection of the host computer and ensure that the weighing result is being transmitted to a valid device. This should resolve the issue and
KM-ASSYM2-01
91
M7090
M7090-The dispensing area detected by the upper camera is not within the range
Visual abnormality
M7090 errors usually occur when the printing head, the camera, or the paper tray is not in proper alignment. Before resolving the error, ensure that the paper tray is properly loaded, the camera is positioned correctly, and the printing
KM-ASSYM2-01
92
M7091
M7091-Scan code OK and receive TE Read signal timeout
Kazam exception
There could be various reasons why you are encountering the M7091-Scan code OK error along with TE Read signal timeout when scanning a code. Some possible solutions include updating your firmware, ensuring that your scanner is sufficiently powered
KM-ASSYM2-01
93
M7092
M7092-TE LINK out of range
Kazam exception
The solution for M7092-TE LINK out of range error depends on the context and the device in question. It can be resolved by adjusting the network settings, updating the firmware, or performing a hardware reset. In some
KM-ASSYM2-01
94
M7093
M7093-TE LINK timeout
Kazam exception
The M7093-TE link timeout error typically occurs when there is a problem with the connection between two devices. To resolve this issue, you will need to check the cable connections and ensure that they are secure. If the problem persists
KM-ASSYM2-01
95
M7094
M7094-The scan code of this site is OK, TE replies that the previous section has not passed the site or SFC failed to transmit data
Kazam exception
The solution to the error M7094 can be found by checking if the previous section of your scan has passed. If not, go to the previous section and repeat the scan. Alternatively, try to reset the SFC (Surface and
KM-ASSYM2-01
97
M7096
M7096-Weighing machine communication abnormality
Electronic control abnormality
The M7096 error on a weighing machine indicates communication abnormality. The solution may involve resetting the machine, checking for any software updates, or contacting the manufacturer for further assistance. This issue typically occurs when the machine cannot
KM-ASSYM2-01
98
M7097
M7097-The cylinder position of the glue barrel is abnormal
Organizational Abnormality
M7097 errors occur when the glue barrel's cylinder position is abnormal. To resolve this issue, you can try calibrating the glue barrel, checking for blockage in the cylinder, or performing a manual
KM-ASSYM2-01
99
M7098
M7098-The current position of the PCB board exceeds the safe distance, please check whether the PCB board is placed properly
Other exceptions
The error M7098 indicates that the PCB board is not placed properly. This issue can be resolved by rechecking the PCB board's position and ensuring that it is within the safe distance allowed for PCB placement. If
KM-ASSYM2-01
100
M7099
M7099-The current position of the PCB board is lower than the safe distance, please check whether the PCB board is placed properly
Other exceptions
The solution to M7099 error code is to check the placement of the PCB board in a safe distance, either by physically adjusting the board or fixing the position of the jig or fixture using the appropriate tools. It is crucial
KM-ASSYM2-01
102
M7101
M7101-Please clean the scale pan and press the "Scale Pan Easy Clean Button"
Abnormal personnel operation
The solution for the error M7101 is to clean the scale pan using a cleaning tool provided by the scale manufacturer, and then to press the "Scale Pan Easy Clean Button" to reset the scale. If the problem persists, the
KM-ASSYM2-01
103
M7102
M7102-Weighing machine reset failed
Electronic control abnormality
M7102-Weighing machine reset failed error typically occurs when the machine cannot initialize due to an incorrect password or issue with its software. To resolve this, consult the owner manual for instructions on resetting the machine and updating its firm
KM-ASSYM2-01
113
M7112
M7112-Visual software model number is inconsistent with PLC model number
Visual abnormality
The solution to the M7112 error is to check that the visual software model number matches the PLC model number. If both numbers are correct, then the error may be caused by a mismatch between the cable connections, power supply,
KM-ASSYM2-01
114
M7113
M7113-Current discharging point index is out of range
Visual abnormality
The solution to the M7113 error involves updating the current discharging point settings on the device in question to within the specified range. This can typically be done through the device's user manual or settings interface. If the issue pers
KM-ASSYM2-01
115
M7114
M7114-Timeout waiting for dispensing result
Visual abnormality
The M7114-Timeout waiting for dispensing result error typically occurs when the system is unable to complete a dispensing operation within a specified time limit. The solution may involve troubleshooting the hardware or software, adjusting the time
KM-ASSYM2-01
116
M7115
M7115-The discharge point exceeds the index range
Visual abnormality
The error "M7115-The discharge point exceeds the index range" indicates a problem in the discharge of stored procedures. To resolve this issue, you can check the discharge point value and modify it within the index range
KM-ASSYM2-01
117
M7116
M7116-Timeout waiting for next action
Machine communication abnormality
The M7116-Timeout waiting for next action error typically occurs when a software process is awaiting user input or a system event but is not receiving it within a specified timeout period. The solution may involve increasing the timeout limit, optimizing
KM-ASSYM2-01
120
M7119
M7119-CMC responded with incorrect material number confirmation information
Abnormal personnel operation
The solution for M7119-CMC responding with incorrect material number confirmation information is to review and double-check the material number being entered, ensure it follows the correct format, and try resetting the device or running material verification checks.
KM-ASSYM2-01
121
M7120
M7120-The function of confirming the material number of the host computer CMC has been blocked
Other exceptions
To resolve M7120 error, ensure that the host computer CMC is functioning properly and has the necessary permissions to access the material number confirmation function. You may also need to update the system or application software to the latest version. If the
KM-ASSYM2-01
119
M7118
M7118-CMC reply material number confirmation message timeout (10S)
Machine communication abnormality
The solution for the error M7118-CMC reply material number confirmation message timeout is to increase the timeout period to 10 seconds or set it to an appropriate value based on the system's requirements. Alternatively, checking the
KM-ASSYM2-01
21
M7020
M7020-The equipment slide table has not returned to the origin, please execute the slide table return to the origin first
Abnormal personnel operation
The solution for the M7020 error is to execute the slide table return to the origin first before attempting any other operation on the equipment.
KM-ASSYM2-01
35
M7034
M7034-The feeding conveyor belt in the work area has run timeout, please check whether the machine is jammed
Organizational Abnormality
The solution for the error described as M7034 is to check if the feeding conveyor belt is jammed. If it is, troubleshoot the problem and clear any obstructions. If the problem persists, seek technical support from
KM-ASSYM2-01
38
M7037
M7037-The discharging operation of the rear buffer conveyor belt times out, please check whether there is any jamming between the upper and lower reaches of the machine
Organizational Abnormality
M7037 error occurs when the discharging operation of the rear buffer conveyor belt times out and there is jamming between the upper and lower reaches of the machine. The solution is to clear any jamming in the machine, ensuring
KM-ASSYM2-01
42
M7041
M7041-The lifting cylinder in the work area is abnormally descending (X32), please check whether the cylinder is stuck when descending
Organizational Abnormality
The solution for the M7041-The lifting cylinder in the work area is abnormally descending (X32) error is to check if the cylinder is stuck when descending. If it is stuck, the cyl
KM-ASSYM2-01
43
M7042
M7042-The conveyor belt width adjustment cylinder extends abnormally (X27), please check whether the cylinder is stuck when it rises
Organizational Abnormality
The solution for the M7042 error described as "The conveyor belt width adjustment cylinder extends abnormally (X27)" is to check whether the cylinder is stuck when it rises. If the cylinder is
KM-ASSYM2-01
67
M7066
M7066-X axis left limit is abnormal, far away from the origin end (X6), please check whether the slide table touches the limit
Electronic control abnormality
The M7066 error denotes that the left limit of the X axis is abnormal and far away from the origin end (X6). Checking whether the slide table touches the limit is recommended to solve this issue.
KM-ASSYM2-01
70
M7069
M7069-Y axis front limit is abnormal, close to the origin end (X11), please check whether the slide table touches the limit
Electronic control abnormality
The solution for M7069-Y axis front limit is abnormal, close to the origin end (X11) is to check whether the slide table touches the limit. The problem could be caused by the slide table moving too far
KM-ASSYM1-05
88
M7087
M7087-TE LINK out of range
Kazam exception
The error M7087-TE LINK out of range typically occurs when the TTL setting of a router or access point is too low. To resolve this issue, you can increase the TTL setting on the router or access point,
KM-ASSYM1-05
89
M7088
M7088-TE LINK timeout
Kazam exception
The solution for the error described as M7088-TE LINK timeout involves checking the network connection, verifying the routing settings, and restarting the network or server.
KM-ASSYM1-05
91
M7090
M7090-PLC timed out waiting for the host computer to transmit the MARK point identification signal
Visual abnormality
The M7090-PLC error occurs when the host computer fails to transmit the MARK point identification signal within the specified timeline. To resolve this issue, first confirm that the host computer is correctly configured and sends the signal within the
KM-ASSYM1-05
92
M7091
M7091-PLC timed out waiting for the host computer to transmit the dispensing point position
Visual abnormality
The solution for M7091-PLC time-out error is to ensure that the host computer is transmitting dispensing point position information to the PLC. The issue could also be caused by communication between the two devices being disabled or
KM-ASSYM1-05
93
M7092
M7092-PLC timed out while waiting for the area identification completion signal from the host computer
Visual abnormality
The solution for the M7092-PLC timed out error involving area identification completion signal from the host computer could be to reduce the timeout value in the PLC configuration, check for network connectivity issues or congestion, or
KM-ASSYM1-05
95
M7094
M7094-PLC timed out waiting for the signal from the host computer to complete the electronic scale clearing
Visual abnormality
M7094-PLC timed out waiting for the signal from the host computer to complete the electronic scale clearing can be resolved by checking if the host computer is properly connected and also ensuring that there are no delays or issues with the
KM-ASSYM1-05
96
M7095
M7095-PLC timed out waiting for the host computer to transmit the weighing result
Machine communication abnormality
The solution for M7095-PLC timed out waiting for the host computer to transmit the weighing result can be resolved by checking the communication settings in the PLC and making sure they are correct, resetting the PLC and
KM-ASSYM1-05
97
M7096
M7096-Weighing machine communication abnormality
Electronic control abnormality
The M7096 error on a weighing machine indicates communication abnormality. The solution may involve resetting the machine, checking for any software updates, or contacting the manufacturer for further assistance. This issue typically occurs when the machine cannot
KM-ASSYM1-05
98
M7097
M7097-The cylinder position of the glue barrel is abnormal
Organizational Abnormality
M7097 errors occur when the glue barrel's cylinder position is abnormal. To resolve this issue, you can try calibrating the glue barrel, checking for blockage in the cylinder, or performing a manual
KM-ASSYM1-05
100
M7099
The current position of M7099-PCB board is lower than the safe distance, please check whether the PC board is placed properly
Other exceptions
The solution to the error "The current position of M7099-PCB board is lower than the safe distance, please check whether the PC board is placed properly" would be to double-check the placement of the M709
KM-ASSYM1-05
101
M7100
M7100-Please clean the scale pan before starting the machine, and click the Cleared button before starting the machine.
Abnormal personnel operation
The solution for this error is to clean the scale pan and click the "Cleared" button before starting the machine. If the pan cannot be cleaned, the machine must be powered off and unplugged for at least 30 minutes before
KM-ASSYM1-05
103
M7102
M7102-Weighing machine reset failed
Electronic control abnormality
M7102-Weighing machine reset failed error typically occurs when the machine cannot initialize due to an incorrect password or issue with its software. To resolve this, consult the owner manual for instructions on resetting the machine and updating its firm
KM-ASSYM1-05
104
M7103
M7103 - The scan code of this site is OK, TE replies that the previous section has not passed the site or SFC failed to transmit data
Kazam exception
The solution for the error M7103, where SFC failed to transmit data before the previous section passed the site scan, is to make sure that the SFC (Scan Flexible Charge) cable is properly connected to the printer
KM-ASSYM1-05
105
M7104
M7104-The host computer did not read the READ signal sent by TE, LINK fail
Kazam exception
The M7104 error indicates that the host computer failed to read the READ signal sent by TE (Telecom Equipment) and resulted in a LINK fail. This issue may occur when the fiber optic cable is damaged, or there is
KM-ASSYM1-05
114
M7113
M7113-Current discharging point index is out of range
Visual abnormality
The solution to the M7113 error involves updating the current discharging point settings on the device in question to within the specified range. This can typically be done through the device's user manual or settings interface. If the issue pers
KM-ASSYM1-05
115
M7114
M7114-Timeout waiting for dispensing result
Visual abnormality
The M7114-Timeout waiting for dispensing result error typically occurs when the system is unable to complete a dispensing operation within a specified time limit. The solution may involve troubleshooting the hardware or software, adjusting the time
KM-ASSYM1-05
116
M7115
M7115-The discharge point exceeds the index range
Visual abnormality
The error "M7115-The discharge point exceeds the index range" indicates a problem in the discharge of stored procedures. To resolve this issue, you can check the discharge point value and modify it within the index range
KM-ASSYM1-05
117
M7116
M7116-Timeout waiting for next action
Machine communication abnormality
The M7116-Timeout waiting for next action error typically occurs when a software process is awaiting user input or a system event but is not receiving it within a specified timeout period. The solution may involve increasing the timeout limit, optimizing
KM-ASSYM1-05
118
M7117
M7117-The number of required assemblies is more than the number of positioned cameras
Other exceptions
The M7117 error occurs when the number of required assemblies exceeds the number of positioned cameras in a camera-based manufacturing process. To resolve this issue, you can either increase the number of positioned cameras or optimize the assembly
KM-ASSYM1-05
119
M7118
M7118-CMC reply material number confirmation message timeout (10S)
Machine communication abnormality
The solution for the error M7118-CMC reply material number confirmation message timeout is to increase the timeout period to 10 seconds or set it to an appropriate value based on the system's requirements. Alternatively, checking the
KM-ASSYM1-05
120
M7119
M7119-CMC responded with incorrect material number confirmation information
Abnormal personnel operation
The solution for M7119-CMC responding with incorrect material number confirmation information is to review and double-check the material number being entered, ensure it follows the correct format, and try resetting the device or running material verification checks.
KM-ASSYM1-05
121
M7120
M7120-The function of confirming the material number of the host computer CMC has been blocked
Other exceptions
To resolve M7120 error, ensure that the host computer CMC is functioning properly and has the necessary permissions to access the material number confirmation function. You may also need to update the system or application software to the latest version. If the
KM-ASSYM1-07
6
M7007
Alarm: pressing position blocked_sensor double lights
Organizational Abnormality
There are several possible causes for this error, including a malfunctioning light sensor or an issue with the camera. However, the most common solution is to clean the affected area thoroughly and try again. If the problem persists, contact the manufacturer or
KM-ASSYM1-07
8
M7009
Alarm: pad pushes out cylinder 1_moving position alarm
Organizational Abnormality
The solution for the "pad pushes out cylinder 1_moving position alarm" error would likely involve checking the wiring and making sure that the pad and cylinder are properly aligned. It is recommended to contact a professional mechanic if
KM-ASSYM1-07
32
M7044
Alarm: During initialization, the assembly line materials were not cleared.
Abnormal personnel operation
To resolve the "Alarm: During initialization, the assembly line materials were not cleared." error, ensure that all materials are properly placed and cleared from the assembly line before beginning operations. This can prevent any potential issues during the initial setup of the production
KM-ASSYM2-01
71
M7070
M7070-Y axis rear limit is abnormal, far away from the origin end (X10), please check whether the slide table touches the limit
Electronic control abnormality
The solution to the M7070-Y axis rear limit abnormal issue is to check if the slide table is touching the limit or if it has moved too far from the origin end (X10). If the slide table is touching
KM-ASSYM2-01
82
M7081
M7081-PLC timed out waiting for the host computer to transmit the MARK point identification signal
Visual abnormality
The M7081-PLC timed out waiting for the host computer to transmit the MARK point identification signal error usually occurs when the PLC is unable to receive or interpret the signal from the host computer within the specified time limit.
KM-ASSYM2-02
11
M80
M80-EMO&&DOOR is on. Please check the safety door and emergency stop switch (X14)
Abnormal personnel operation
The solution for the error M80-EMO&&DOOR is on. Please check the safety door and emergency stop switch (X14) involves resetting the emergency stop button and ensuring that the safety door is closed before starting the machine
KM-ASSYM2-02
1
M70
M70-The left labeling machine is out of material
Abnormal personnel operation
This error often occurs when the labeling machine runs out of labels or label stock. To solve it, ensure that the label machine has enough labels or label stock, and that the labels are properly loaded into the machine. Check the machine's settings
KM-ASSYM2-02
6
M75
M75-Start detecting that there is material in the work area, please select the work area status
Abnormal personnel operation
The solution for the M75-Start error is to select the work area status as "Clear" before starting the machine. If the work area is not clear, the machine will not start and will display this error message.
KM-ASSYM2-02
13
M82
M82-Please press the reset button before starting the automatic process
Abnormal personnel operation
The solution to the M82 error described as "Please press the reset button before starting the automatic process" is to press the reset button and then restart the device or application that is producing the error. This will often clear any corrupted files or
KM-ASSYM2-02
14
M83
M83-The device has not returned to the origin, please execute the device to return to the origin first
Abnormal personnel operation
The solution to the M83 error is to perform a device initialization or power cycle by turning off the radio and then back on to reset the device's location and return it to its starting point.
KM-ASSYM2-02
15
M84
The communication connection between M84-PLC1 and PLC2 is interrupted
Machine communication abnormality
The solution for the error described as "The communication connection between M84-PLC1 and PLC2 is interrupted" may involve checking the communication protocols, ensuring proper termination of the connection, checking the modems and communication cards,
KM-ASSYM2-02
18
M87
M87-Front buffer conveyor belt discharging operation timeout
Organizational Abnormality
The solution for the M87-Front buffer conveyor belt discharging operation timeout error could involve checking the connection between the conveyor belt and the motor, ensuring the belt speed is appropriate, and verifying that there are no obstructions in
KM-ASSYM2-02
19
M88
M88-Work area inlet conveyor belt operation timeout
Organizational Abnormality
The solution for the M88-Work area inlet conveyor belt operation timeout error could involve adjusting the conveyor belt speed, updating or replacing the equipment, or contacting the manufacturer for assistance. Regular maintenance can also help prevent this error
KM-ASSYM2-02
20
M89
M89-Work area discharging conveyor belt operation timeout
Organizational Abnormality
The solution to the M89-Work area discharging conveyor belt operation timeout error typically involves cleaning the belt and belt feeder, removing blockages, and adjusting the conveyor speed. If the error persists, you may need