Problem Statement: When you get a template and try to open in Window 7, 64 bit, you see the cell formula including the Report Writer (RW) file AspenRpt.xla and its path, such as 'C:\PROGRA~2\MICROS~2\Office14\Library\!AspenRpt.xla'. The template does not resolve all the formulas? How can we remove it? | Solution: In Excel, open window Trust Center from File | Options | Trust Center -> 'Trust Center Settings ...', then select Trusted Locations from the left. Check the box on the bottom for 'Allow Trusted Locations on my network'.
Close Excel. and reopen it. The whole path in the cell will be removed. And you can go bac... |
Problem Statement: When running reports, I receive error messages with the Icarus_User.mdb file and a Crystal Reports Database error.
Some of the messages are: Error 3044 - Icarus_User.mdb is not a valid path - Import | Solution: This problem occurs when you are using the Icarus_User.mdb file in order to create your own custom reports (see otherSolution document referring to custom reports: http://support.aspentech.com/webteamcgi/SolutionDisplay_view.cgi?key=113318).
With v2006 of the Icarus software, there was a change made with di... |
Problem Statement: How are nuts and bolts generated by the Aspen Icarus software? | Solution: Bolt and nut sizes are determined by ASME code (and by BIS/JIS/DIN codes, but they are all copies of ASME code, except for DIN code in some diameters).
Those bolt sizes and quantities are tabulated by Pipe diameter and flange rating and included within the evaluation engine.
For example, below is one of those... |
Problem Statement: How to configure Aspen Demand Manager forecast by date? | Solution: AspenTech strongly discourages using days to forecast. It is too detailed a level to get good statistical forecasts and it can quickly blow up the size of the application so that it cannot run in memory.
Typically, when a Demand Manager application needs to deal with days, it is either
1. Simply for o... |
Problem Statement: Does the Icarus piping length calculation include waste during fabrication? | Solution: No.
Keywords: weld, welding, shop fab, field fab
References: None |
Problem Statement: How is the Override_ID number in the Manage Override screen of Collaborative Forecasting (CF) generated? | Solution: The Override_ID number is generated from Oracle via a sequencing program and trigger. The ID number is applied to the override in CF. When CF sends that override to Demand Manager, the ID number is also sent.
ID numbers are not stored in an Oracle table. The table in Oracle only saves the last number used.
Ke... |
Problem Statement: You recently changed your CFOWNER password and now Publish to CF is failing.
Aspen Collaborative Demand Manager(DM) did not throw any errors after publishing, but noticed that the CF Return
Code Message displaying previous months (05/02/2011) time stamp and Data
last published to CF and current m... | Solution: To resolve this, you must reset the password in jdbc.ini file.
Keywords: None
References: None |
Problem Statement: Is it possible to make a weekly bucket model in Aspen Demand Manager?
? The Configure Time Periods screen allows selection of a Model start month; is it possible to select a Model start week instead?
? Aspen Demand Manager allows generation of forecasts by weekly bucket, but is it... | Solution: 1. We do not typically recommend doing weekly forecasting. Forecasting at that level can hinder the forecast algorithms ability to pick up seasonal patterns and it can have a very big impact on the size and memory requirements of the implementation because all periods in PER have to be in weekly buckets... |
Problem Statement: I am not getting an insulation cost for my piping component. How do I achieve this? | Solution: Two items must be defined in the component specs form in order to get insulation cost for your piping component...entering only 1 of the 2 will not generate the insulation:
1. Specify PPROT in the Special Pipe Description field.
2. Specify the Personnel Protection percent in the Personnel Protection field.
Ke... |
Problem Statement: Why am I getting more flanges than I am specifying when using flange type FL ? | Solution: Economic Evaluation products have two different options for flange count. You can use either FL or FT. FL is used for all flanges excluding flanges on valves. FT is the flange count used for all flanges including flanges on valves. If you use FL and have valves on your line, the system will also generate the ... |
Problem Statement: Is it possible to adjust the distance between supports for above ground piping? | Solution: No.A The distance is calculated by the Above Ground Piping model and is a function of the piping size.
Keywords: support, piping, pipe support
References: None |
Problem Statement: Does Primavera have to be installed on the same machine as Aspen Capital Cost Estimator or Aspen In-Plant Cost Estimator? Or can I have them on different machines and export my schedule and then import it into Primavera? | Solution: Aspen Capital Cost Estimator or Aspen In-Plant Cost Estimator have to be on the same machine as Primavera. Though the steps have the appearance that the file is exported to Primavera, we use the API integration, so it is actually tied to Aspen Capital Cost Estimator and Aspen In-Plant Cost Estimator.
Keywords... |
Problem Statement: I am getting the error message, DefaultWB is alreday open when I try running my custom report. What could be the problem? | Solution: This is often caused by someone using a logo as a picture instead of an object in their custom report. This issue occurs because the logo was not inserted as an object. The logo should always be inserted as an object. If it is inserted as a picture then it may not work.
Keywords: logo, object, picture, Defaul... |
Problem Statement: How to connect SQL database to report writer template Orion_BlendReports? | Solution: Following steps can be followed:
1. Simulate All and Publish All
2. Create RW queries
3. Goto the local working folder and run the query SQL_Server_Create_Views.sql
4. Run the SQLServer_Create_N_Fill_TWLibrary.sql file on the server to create table TW_Library.
5. This will create rep... |
Problem Statement: If I enter a workforce productivity and a craft productivity, what do the Economic Evaluation products do? | Solution: The crafts that have the productivity entered, they system will use the entered craft productivity. For all other crafts it will use the workforce productivity. It does not compound the productivity.
Keywords: Productivity, craft, craft productivity
References: None |
Problem Statement: | Solution: 130431 has a Report Writer template to generate a report of the PROCLIM data. However, that template does not include the description for the Process Capacity tag. Attached to thisSolution is an updated version of the Report Writer template which includes the tag description.
Solution
The template is attached... |
Problem Statement: Where can I find the Installation Options field in V8? I can no longer find it on the Installation bulks | Mata??l/man-hour adj., vessel tracing form. | Solution: In V7.3.2 and earlier versions, on process equipment, plant bulks, quoted cost tems and equipment model library (EML) items, there was an input field for Installation option on the Installation bulks | Mata??l/man-hour adj., vessel tracing form.
This field has now been moved to the main form. It is located ... |
Problem Statement: Where can I find the different Item classifications and Item types available in my Economic Evalution product? | Solution: The list of all the Economic Evaluation Item classifications and Item types can be found in Chapter 1 of the Aspen Icarus
Keywords: Item classification, Item type
References: Manual in. Click on the links for Process Equipment Categories and List of Process Equipment for the complete list. |
Problem Statement: What pipe diameter sizes are allowed in Custom Pipe Specs? | Solution: In V7.3.2 or earlier, users could specify three diameter breaks (Small, Medium and Large) in the custom pipe specs. Starting with V8, two additional diameter breaks (Extra-small, Extra-large) have been added to custom pipe specs input form. In addition, the pipe/fittings material adjustment, pipe valve materi... |
Problem Statement: What is the maximum number of custom pipe specs per library file and per project? | Solution: Aspen Capital Cost Estimator and Aspen In-Plant Cost Estimator are able to handle and manage a larger number of custom pipe specifications. Specifically:
? Create and edit 999 custom pipe specs in the custom pipe spec library.
Use a library with 999 or create 999 custom pipe specs in the design basi... |
Problem Statement: What is reported in Project / Area - AREA in my Maxiblock report? | Solution: These are the things that are appearing:
Piping - hydrostatic testing
Instrumentation - testing
Electrical - MCC, Starters, panelboard, testing
Keywords: Maxiblock, testing, area
References: None |
Problem Statement: Sprinkler Fire System is only giving A53 and SS for my piping; is there away to get galvanized pipe? | Solution: There are no options for material type, but you can use a work around by choosing plant bulk piping to put in the actual piping for your galvanized pipe and couplings. It would go something like this:
Run the sprinkler plant bulk and take a look at the results. The sprinklers and the dry pipe valves will be ... |
Problem Statement: How can I remove my piping rework (COA 307) from my Aspen In-Plant Cost Estimator project or Aspen Capital Cost Estimator project? | Solution: By default, there is a pefab pipe rework cost (10 % except UK and EU, which is 12.5% of piping cost). This can not be changed directly through an input form field, but can be changed by indexing COA 307 to zero:
Keywords: prefab piping rework, rework, COA 307, 307, rework
References: None |
Problem Statement: How can I adjust how often my Projects are backed up? | Solution: By default, Projects are backed up every 30 minutes. You can adjust this interval by going to the Backup tab on:
Tools | Options | Preferences
You can then adjust the time up or down under Timed Backup (Interval, in minutes)
Keywords:
References: None |
Problem Statement: How to delete multiple components? | Solution: Go to Project View and have the List view in the center pane
In the List view, click on the Components you wish to delete.
Hit the Delete Key and you will be prompted to clarify this is what you want to delete.
Choose YES and it will delete the selected Components.
Keywords: None
References: None |
Problem Statement: How can I have my backup saved under a unique name? | Solution: You can set the system to save the files with unique names by going to:
Tools | Options | Preferences
And choosing the ?Backup
And choosing the ?Backup/Recovery? tab. Once the new form opens, select ?Unique Project Backups?
Please beware, having the backup's saved with unique names can cause many files t... |
Problem Statement: What piping and instrumentation bulks are included in centrifugal compressor models? | Solution: For piping and instrumentation bulks related to the compressor, the user can see the documentation to determine whether the P&ID for the compressor covers their requirements. The compressor P&ID includes piping and instrumentation for compressor inlet, discharge (from last stage) and the lube-oil system. It d... |
Problem Statement: Why do I only see Pipe Testing COA 306 for one area in my project? | Solution: The Pipe Testing (COA 306) and Instrument Tesing (COA 691) in Aspen In-Plant Cost Estimator are always reported in the last (bottom) area listed in the Project View.A What is reported is for all areas, not just the one area.
Keywords: Pipe Testing, Instrument Testing, COA 306, COA 691, 306, 691
References: No... |
Problem Statement: Is it possible to change the default light fixture of electrical bulk item (installation bulk)? | Solution: It is not possible to change the default light fixture (Mercury Vapor/Explosion proof) of electrical bulk item (installation bulk).
The workaround for this can be to specify lighting as plant bulk and not as installation bulk.
Follow the steps below to add lighting as plant bulk with required light fixture ... |
Problem Statement: Do the economic evaluator products include the steam headers when I choose P-SP Tracing (Pipe Connection/Spiral Traced)? | Solution: No it does not include the steam header costs. It will calculate the cost for the supply and return sub-headers, but it assumes an exiting steam header.
Keywords: None
References: None |
Problem Statement: I have a component, under which electrical bulk is specified as below. Why is there is no electrical cost generated for that component? | Solution: Voltage is needed to generate cost for component electrical bulk item. For starters, it requires the specification of voltage and power. For wire runs, it requires the specification of voltage and power, or voltage and wire size.
Keywords: Electrical bulk
References: None |
Problem Statement: Does the cost of cable include cable tray? | Solution: In Aspen In-Plant Cost Estimator (AIPCE), if you choose the electrical cable type to be single core wires in tray or multiple core cable in tray, the cost generated by AIPCE does not include the tray. The cost is strictly the cost of the cable and the installation hours for installing the cable in tray. User ... |
Problem Statement: How do I change the units of measure used in custom pipe specs? | Solution: Some units of measure (temperature, pressure, and etc.) can be modified for custom pipe spec files using IP or Metric base units. To modify them, close any open project and right click on the custom pipe spec file located under Library tab | Custom Piping Specs | Inch-Pound or Metric in Palette window, then M... |
Problem Statement: When I try to choose pipe material (or equipment or electrical), I am not getting all the additional options in the material selection. For example the pop up box does not appear, rather the program gets stuck (with ping sound). | Solution: The ping sound probably is because you are clicking in the GUI form but the window is open elsewhere (it is a modal dialog).
Likely, you may be using 2 monitors. As long as you open Aspen Capital Cost Estimator (ACCE), Aspen In-Plant Cost Estimator (AIPCE), or Aspen Process Economic Analyzer (APEA) on the ... |
Problem Statement: When I look at the Indirects input forms in Aspen In-Plant Cost Estimator, the fields all have a zero in them and do not generate any indirect costs; but when I look at my forms in Aspen Capital Cost Estimator, the fields are blank but generate indirect costs; what is the difference? | Solution: The default craft wages in Aspen In-Plant Cost Estimator (AICE) are loaded wages where the default craft wages in Aspen Capital Cost Estimator are unloaded wages. What this means is that the AICE wages include all the indirect costs, except rental equipment. The wages in ACCE do not include the indirect cos... |
Problem Statement: I am using Aspen In-Plant Cost Estimator V8.0 and can not find the Special Options field in the M'l/Man-hour%Adj that I use to turn Demolition on in my project?A How can I do Demolition? | Solution: Starting in V8.0, in all the Economic Evaluation products (Aspen In-Plant Cost Estimator, Aspen Capital Cost Estimator, and Aspen Process Economic Analyzer), the Demolition option was moved to the main form and is in a new field named Installation Option.A The default is Standard Installation, and to do a Dem... |
Problem Statement: When developing Report Writer templates, you may notice that some structures to retrieve data work in template mode, but they do not work in execution mode.
In many cases, this problem is related to the sequence in which the Report Writer functions are executed; in template mode, all functions are ex... | Solution: These are some structures that will work in template mode and will fail in execution mode:
1. In a sheet you refer to a data set function in a previous sheet, for example an ATGValue() function that retrieves data from the ATDSPCapacities() function in the previous sheet. The row where this ATDSPCapacities(... |
Problem Statement: When I adjust the Percent of welds in shop on my Pipe bulk - item details form, why is there no change in the number of welds being done in the field? | Solution: Check your range in Project Basis View for your Remote Shop Diameter.  If your pipe diameter is smaller than the minimum or larger than the maximum diameter, then it already is being done in the field and the Percent of welds in shop field will have no affect.
Keywords: remote shop, field, remote, welds
Re... |
Problem Statement: Does Economic Evaluator use a different productivity for Shop vs Field Piping? | Solution: Yes. It assumes the Shop is 18 percent more productive than the Field.
Keywords:
References: None |
Problem Statement: How do I run Primavera 6 from Aspen In-Plant Cost Estimator? | Solution: First you need to make sure that Aspen In-Plant Cost Estimator sees P6. If you check page 12 of the Aspen Economic Evaluator V7.2 Release notes, it discusses where to look to do this (which is Tools | Options | Preferences (Schedule)). Note, it does not specifically say P6, so choose P3E. We have specific... |
Problem Statement: Which version of Primavera are supported with V7.2 Aspen In-Plant Cost Estimator? | Solution: Supported version of Primavera with V7.2 of Aspen In-Plant Cost Estimator are P3, P5 and P6.
Keywords: Primavera, IPM
References: None |
Problem Statement: When running and Aspen Report Writer template, I do not get data for all my cases. I only see data for the cases included in the last PIMS run that I made. Why is this? | Solution: When an Aspen Report Writer template is run you will see the dialog box below.
Notice that the default value for theSolutionIDs option is LAST. This tells Aspen Report Writer to only retrieve data that has the lastSolution ID. Since each PIMS run has a differentSolution ID, this means only the cases that we... |
Problem Statement: When I run a project evaluation or an item evaluation, it takes a very long time for it to complete. It's really slow and taking way long to run.
Is there any way to speed things up? | Solution: There are a few things that can be done to fix this problem.
1. The main reason for slowness could be due to a license problem. Not that the license is bad or corrupted, but it may not be configured quite properly through the SLM Configuration Wizard.
1. The specification of the type of license file in the SL... |
Problem Statement: What work items does Code of Account (COA) 614 - Temperature Transmitters - include? | Solution: Man hours for Code of Account (COA) 614 include checking out of storage, hauling to erection site, calibrating, installing, testing, and final inspection.
Keywords: COA, Code of Account
References: None |
Problem Statement: When I try to run my Primavera schedule through IPM, it starts to work, and then the cost result database window disappears and no Primavera report is shown. | Solution: The path that where Aspen Icarus Project Manager is installed to, is too long. The default path is D:\Program Files\AspenTech\Aspen Icarus 2004.2 (which is 46 characters long, including all characters AND spaces).
The path limitation is 56 characters total.
Keywords: P3, primavera, schedule
References: None |
Problem Statement: I have some old Icarus System Devices that I would like to return. Where should I send them to? | Solution: Please return all Icarus System (Firmware) devices to the following location:
Aspen Technology, Inc.
Attn: Michel McCormack
704 Quince Orchard Road, Suite 150
Gaithersburg, MD 20878
phone: 301-944-2500
Keywords: firmware
Icarus
system device
dongle
References: None |
Problem Statement: I am getting an access denied error message when opening my project; what might be causing this error message? | Solution: When the file is created in a new release and then you try to open it in an older release you will get the access denied error message. For example, if you create a project in V7.2, and later try to open it in V7.1, you will get the access denied error message
Keywords: None
References: None |
Problem Statement: When I open up IPM/Kbase/IPE, I immediately get an error message saying:
Program Error ICARUSKB.exe has generated errors and will be closed by Windows.
This can happen if you have changed your default project location to a path that does not exist OR if you have specified more than 9 Alternate Projec... | Solution: This is an easy fix. Run the Preferences Tool (can be run outside of the software), and remove one or more Alternate Project Directories that go over the 9 allowable limit. You can also reset your project location to the default so that you will be able to open the software.
Here's how to do it:
Go to your As... |
Problem Statement: How does the Icarus software calculate the equivalent lineal footage for valves and fittings for piping insulation? | Solution: Here is the formula:
User gets 100% of pipe length plus an additional 5% for wastage. (You don't add in the 5% waste until you add in all the valves and fittings first).
AND
Also gets +4 ft (1.2192 meters) for EACH fitting AND +15 ft (4.572 meters) for EACH valve. (A fitting includes the elbows, tees, etc, an... |
Problem Statement: Does the number of impellers represent the number of stages on a centrifugal compressor? | Solution: No, the number of impellers does not represent the number of stages. A single stage may have multiple impellers. NOTE: On the design data sheet there is a ?Power per stage? entry but it is actually a power per impeller value.
Keywords: Impeller, multiple stage, centrifugal compressor
References: None |
Problem Statement: Does Economic Evaluator use standard efficiency or high efficiency motors? | Solution: Economic Evaluator uses standard efficiency motors.
Keywords: motor, efficiency, high efficiency, standard efficiency
References: None |
Problem Statement: 1036922Customer has question as to which component to use for underground yellow jacket pipe installation | Solution: Use above ground or buried pipe and then under special pipe description you select the full jacket.
provide buried depth which is only applicable for buried pipe.
Keywords:
References: None |
Problem Statement: I have several versions of Hysys installed in my system. How can I run a selected version of the product rather than the default version? | Solution: Download the attached batch file. Run it to select the version which you would like to run when you double click on your models.
Keywords: Hysys
Multiple
Versions
References: None |
Problem Statement: How to open files with extention .izp and *.szp | Solution: The steps are as below:
1. Save both .izp and .szp files under the folder with the same name of izp and szp files. You can consider that as your scenario folder.
2. Create the directory in your machine which will be one of your project directories. It can be your old directory too. Now create a new fo... |
Problem Statement: How can I use the ATDSRange() function to create a data set from a range of cells in the MS Excel template? | Solution: Aspen Report writer normally retrieves data from a results.mdb, but sometimes, we may need to pull some data from the Excel template itself in addition to the results.mdb.
The ATDSRange() function allows you to define a Data range in the template itself so that you can pull the data from the range (i.e. it cr... |
Problem Statement: I would like to know the weight of the single pipe segment without accessories. How can I do this? | Solution: The weight of piping reported by the software is the sum of both piping and fittings. If you wish to know how much a single pipe item weights, you can add an Above grade or buried piping and specify the length, diameter, and the material of the pipe
Once you have added this item without any accessories, you c... |
Problem Statement: Is it possible to use default, unloaded wage rates in Aspen In-Plant Cost Estimator (AIPCE) instead of the default, loaded wage rates? | Solution: You can enter and use your own unloaded, wage rages in AIPCE, but you can not have AIPCE use internal, default, unloaded wage rates. The only default, internal wage rates that AIPCE can use will be loaded wage rates.
Keywords: unloaded, loaded
References: None |
Problem Statement: Whenever I run the Excel report “Project – Indirect Summary”, a price for rental equipment is listed, however, running the Standard report “Equipment Rental – Project” no equipment is listed. Where is the price for rental equipment being generated from? | Solution: This happens when you have an entered value in “Equipment rental cost” in the Indirects option of Project Basis View. When you enter a value here, it will override any system generated costs for rental and will automatically report the cost given by the user.
Keywords: Rental equipment, indirects, Equipment r... |
Problem Statement: Why am I not seeing my Total Sensor Cost for option 6, Extra control valve added to another loop? | Solution: Extra control valve added to another location, option 6, does not use sensor loop information If sensor loop information is entered, it is ignored. So even though there may be data for a sensor specified on the form, it is not being used. Since the sensor data is not being used, the Total Sensor Cost is no... |
Problem Statement: Sometimes, Aspen Report Writer does not show up in Excel after the installation. This can happen if the Report Writer DLL is not registered properly. So how do we fix this? | Solution: When the Report Writer DLL is not registered properly, please do the following:
1) In Excel, hit Alt + F11, which will open the VBA editor. Go to Tools |
Keywords: report writer
register
unregister
AspenRpt.dll
References: s and check if there is one line that says Missing: AspenRpt. This would mean that it... |
Problem Statement: How to obtain inside metal wall temperature of a vessel using depressuring utility? | Solution: The inside wall temperature of a vessel is not readily available in the results using the depressuring utility. However this can be calculated based on inner wall and outer wall temperatures.
The conductive heat transfer through a cylindrical vessel or pipe can be calculated by:
Q = 2* PI * L* K * (Ti - To)... |
Problem Statement: What is a 'liquid phase inversion' in a '3-phase separator carry over' setup? | Solution: It is the water fraction at which the system changes from a water-in-oil emulsion to an oil-in-water emulsion is called inversion point
The effective viscosity of an emulsion depends on the properties of the oil, the properties of the water, and the relative amounts of each phase. For a water-in-oil emulsion ... |
Problem Statement: How can I specify and report the flow rate in Nm3/h in my simulation? | Solution: The flowrate can be specified in Nm3/h directly on the molar flow entry in the stream (Worksheet/Conditions page).
The flow can be reported in Nm3/h entering the session Preferences from Tools in the main menu and the Variables Tab and cloning one of the available unit sets and changing the required variable ... |
Problem Statement: Is it possible to display text values on the PFD in Aspen HYSYS? | Solution: New in Aspen HYSYS 2006.5, text values can be displayed in PFD tables. Due to new functionality introduced in this version of Aspen HYSYS, there are at least two situations in which this may be necessary: spreadsheet cells and user variables containing text values.
Keywords: PFD, text, value, spreadsheet, use... |
Problem Statement: The D86 95% (Petrol) point calculated by property Correlation Manager and Boiling point utility are different. | Solution: In HYSYS, user should not apply D86 95% correlation on stream using property Correlation Manager because this will give a different D86 Petrol Point result than Boiling Point utility. In HYSYS only the Boiling Point utility and Cold Property utility will give correct D86 temperatures.
In RefSYS, user can appl... |
Problem Statement: How to copy a material stream along with the utility (eg.depressuring utility) from one simulation file to another? | Solution: There can be a scenario where you need to copy a stream along with the attached utility from one large simulation to the other to continue further study on it. For example, you have a huge steady state simulation with large number of unit operations, subflowsheets and logical operators and want to carry out t... |
Problem Statement: Is it possible to specify and report volumetric flowrate at normal conditions using Aspen HYSYS? | Solution: To input volumetric flow rate in normal conditions (0C and 1 atm) choose Nm3/h as the unit when entering molar flowrate.
To report calculated volumetric flow rates at normal conditions, open your session Preferences and select Nm3/h as the unit of measure for Std Gas Flow. Note that you will need to clone the... |
Problem Statement: What's New in Aspen HYSYS V7.2 - New Functionality in Aspen Properties | Solution: Aspen HYSYS V7.0 introduced access to the Aspen Properties chemical compound databases and physical and chemical property calculation methods. This introduction more than doubled the thermodynamics capabilities of HYSYS, and made over 13,000 new compounds (mostly organic) available to HYSYS users.
The enabled... |
Problem Statement: How do I add the additional tabs in EDF file? | Solution: In order to add additional tabs in the EDF interface, you first click the bottom of tab and highlight the name of tabs. If you click the right button (P1), you select Page tabs properties .
Figure: P1
You add additional tabs, for example: Parameters, Results tabs. You need assign a value for each tab (Paramet... |
Problem Statement: In new license file, we could not find any keys such as SLM_Extensions_OLGAS, SLM_Extensions_PIPESYS, SLM_HYSYS_OLGAS, SLM_HYSYS_OLGAS3P for OLGAS in Pipesys and pipesegment. Do we need any additional license keys from Aspentech to run OLGAS in PIPESYS after getting the license from SPT group in Hysy... | Solution: After October 31, 2010, AspenTech no longer offers the PIPESYS or OLGAS technologies from SPT Group as part of our aspenONE Engineering suite. Customers have to license either PIPESYS or OLGAS directly from SPT Group.
Customer will need to install V7.2 CP2 and hotfix (130562) from the support site. After that... |
Problem Statement: Results displayed in Aspen HYSYS do not match with the results displayed in the TEMA sheet when using HTFS or EDR to design the heat Exchanger.
For example,
- Results in HYSYS
- Results in the TEMA Sheet | Solution: In HYSYS, open the Heat Exchanger window.
Check the Ignored option at the bottom right of the window.
Then uncheck it. The program will update the calculations and the results in the TEMA sheet will match the ones in HYSYS.
Keywords: Heat Exchanger
TEMA sheet
Match results
HYSYS
References: None |
Problem Statement: How does one view pure component properties if using the Aspen Properties database in Aspen HYSYS? | Solution: When using the Aspen Properties database in Aspen HYSYS, the component properties will not be displayed on the standard pure component property view. The properties of a given component can; however, be viewed by the following method:
1. Select the component of interest from the Component List and click t... |
Problem Statement: Why do the tray sizing utility and the rating tab have two different diameter or different results?
Tray sizing utility and Rating tab show two different results. Which one should I trust? | Solution: Results of tray sizing or tray rating utility should be read from from the respective utility. It does not have any connection with the Rating tab in the column view window. The rating tab is for dynamic mode and not for tray sizing purpose. The rating tab contains default numbers. You have to change the diam... |
Problem Statement: What does the API521 for wetted area tick box option (for Fire API52 mode) in the Depressuring Utility do? | Solution: According to the API521 standard or Guide for Pressure-Relieving and Depressuring Systems - API RECOMMENDED PRACTICE 521 1997, only the portion of the vessel that is wetted by its internal liquid and is equal to or less than 25 feet (7.6 m) above the source of flame needs to be recognized. Portions higher tha... |
Problem Statement: New Feature in Aspen HYSYS V7.2 - Improvements in Functionality and Usability of Aspen Hydraulics | Solution: Additional pipe flow and fitting correlations
The capability to model a vertical or inclined flow in Aspen Hydraulics is significantly enhanced through the addition of improved and updated correlations for modeling pipes, complex pipe segments, tees, valves,swages, and so on.
Simultaneous edit of multiple pip... |
Problem Statement: Electrolyte Capabilities in Aspen HYSYS | Solution: Several chemical process calculations involve electrolytic applications. The new capabilities with the help of Aspen Properties in Aspen HYSYS enable the user to analyze and optimize processes involving ionic species, complex ions, and salt precipitation, with strong acids, weak acids, and bases.
Examples o... |
Problem Statement: When you run the installation detail report the quoted cost is not shown in the report. Why? | Solution: The reason for not seeing the cost you specified is you have specified a cost for the Second Control valve for each Loop (bottom of the form) but specified the control valve information (control valve location, valve type, and Remote Control Type) for the primary valve (and not the secondary). If you move the... |
Problem Statement: Error message voltage specified out of range. | Solution: You need to use the voltage for the component which will be consistent with the maximum or minimum or default value in design spec electrical.
If the min value is 6 and max is 13.6 you can not specify something between that. You must use either the minimum or maximum or the default value.
Keywords: None
Refer... |
Problem Statement: Can I create a Template in V7.3 and use it in an earlier version of an Economic Evaluation product (like V7.2)? | Solution: No you can not use a Template from V7.3 in any earlier versions of Economic Evaluator products. The Template feature is new to V7.3 and the earlier versions will not recognize it. Any Templates you create in V7.3 will be able to be used in future releases because they will also have the Template feature
Keywo... |
Problem Statement: Similar to Aspen Plus behavior, a HYSYS model that uses EO subflowsheet usually generates a number of temporary files in between runs. But unlike Aspen Plus, the temporary files are not in the same folder as the model file.
Where are these files located on my hard drive? | Solution: They are located at the Temp folder of the logged-in users' profile folder, for example, C:\Documents and Settings\songt\Local Settings\Temp.
Keywords: Temporary files, EO, equation oriented, Aspen Properties
References: None |
Problem Statement: Are there any example files describing Liquid - Liquid Extraction in Aspen HYSYS? | Solution: In the attached word document tutorial, a simple liquid-liquid extraction process in HYSYS is explained.
A liquid stream containing 60 mol% water and 40 mol% acetone entering at 25 C, 1 atm, and flowing at a
rate of 1 kgmol/s will be extracted with a pure MIBK stream at the same exact conditions as the feed.
... |
Problem Statement: When I use the ATDSP | Solution: s function, I only get one row of data even though the PrSolution table in the Results.MDB file has 49 rows. However, when I use the ATDSQuery function with the stored RW_Solutions query, I do get a dataset with all 49 rows. Why is this?
For example: Use the attached template with the attached Results.MDB... |
Problem Statement: How to model sea water. | Solution: Modeling of sea water really depends on what process parameters you are trying to get out of the simulation. ThisSolution applies to the case in which a non-electrolytic system is created.
First create a hypo component by cloning the pure water library component. After this, the thermal properties of the clon... |
Problem Statement: What are the numerical equivalent of flow regimes in a pipe segment? Flow regimes are reported in numbers in workbook dump. What do the numbers represent? | Solution: Here is list of flow regime numbers and their corresponding names of flow regimes. The list is valid for a pipe segment.
0 = Liquid Only
1 = Vapor Only
2 = Two Phase
3 = Elongated Bubble
4 = Stratified
5 = Slug Flow
6 = Wave Flow
7 = Annular Mist
8 = Dispersed Bubble
9 = Segregated
10 = Transition
11 = Inte... |
Problem Statement: In strip chart, I have activated variable Vessel Inner Wall Temperatures (Vapor)/(liquid1)/(liquid2) but it is displayed as <empty> even after running the depressuring utility. why? | Solution: If you use heat loss model as 'none', the inner wall temperature result will be 'empty'. Wall temperature is only considered when using the 'Detailed' Heat Loss model, otherwise heat transfer to the wall material is not considered and therefore wall temperature is not reported. It is the only model that divid... |
Problem Statement: When user is trying to load DBR PVT Pro Engine (Window Vista or Window 7) in the PVT Environment, an error appears saying 'PVTProExtPkg setup is not successful. | Solution: This is likely due to an error in the registry from installation and there is a workaround the user can do to fix the registry key by following the steps:
1. Open the registry by opening the start menu and typing regedit in the Search programs and files field
2. Allow the program to make changes to the regis... |
Problem Statement: Where can I check Condenser and Reboiler heat curves? | Solution: Condenser and Reboiler results can be viewed directly inside the Column Environment. To enter the Column Environment, open the column property view and click on the Column Environment button. Once inside the column subflowsheet, double click on either the Condenser or Reboiler PFD icon to open the correspondi... |
Problem Statement: This document will help user set up DBR Amine package for amine process modeling. | Solution: The attached document gives step-by-step instructions on setting up DBR Amine package in Aspen HYSYS.
Keywords: Amine, DBR Amine
References: None |
Problem Statement: Absorber column using DEA and Amine Package fails to solve when the feed rate is changed in a large step. | Solution: When the feed rate (eg, sour gas molar flow) is changed in a large step the solver encounters oscillation during convergence. To prevent instability change the damping factor from a default value of 1.0 to a smaller value typically in the range of 0.2 - 0.4.
The damping factor can be found via the Parameters ... |
Problem Statement: How do I prevent the error message the polytropic head factor beign at lower limit or at higher limit? | Solution: The Polytropic Head Coefficient of the compressor has lower and upper limits as 0.6 and 1.4. When the calculation of Polytropic Head Coefficient reach 0.6 and 1.4 limit, the Polytropic Head Coefficient will be set to 0.6 and 1.4. If you want to make sure the Polytropic Head Coefficient calculation not reach t... |
Problem Statement: What is the assay data basis used for oil characterization in Aspen HYSYS?
This | Solution: is intended to clarify the assay basis used for molecular weight, density and viscosity curves (the dependent or independent) in the oil manager.Solution
The assay basis for distillation data can be selected from the drop down options. This can be selected as liquid volume, mass or mole basis. But when you en... |
Problem Statement: How to choose the right RVP method and why it is not solved sometimes and shows empty. | Solution: Aspen Hysys provides different methods to calculate the RVP value. The choice of methods is dependent on your applications and stream conditions. Please refer the following information to choose the correct method.
1. HYSYS RVP Method
The RVP calculation in the HYSYS Cold Properties and Boiling Point Curves u... |
Problem Statement: How to setup a yield shift reactor? | Solution: Yield Shift reactor (YSR): The Yield Shift reactor (YSR) unit operation supports efficient modeling of reactors by using data tables to perform shift calculations. For example if the reactor output is available at three different temperatures say 500C, 600C (base data) and 700 C, then using the linear relatio... |
Problem Statement: How can I add a solid component in Aspen HYSYS? | Solution: Solid components can be added in two different ways in Aspen HYSYS: as a component from the databank or as a Hypothetical component if its properties are known. The guidelines are provided below.
1. Add a component list on the Components tab of the Simulation Basis Manager window in the Basis environment. T... |
Problem Statement: When I double-click on a unit operation or stream icon in the PFD window, Aspen HYSYS does not appear to respond. | Solution: Aspen HYSYS may appear to not respond because the corresponding window was already open in another location within the application desktop (you can verify this by selecting Windows | Arrange Desktop from the main menu). The easiest way to resolve this problem is to first of all close all windows (choose Windo... |
Problem Statement: What does the Apply smart bulk fitting on molecular weight and mass density option do? | Solution: The Apply smart bulk fitting on molecular weight and mass density checkbox can be found on the Light-Ends Handling & Bulk Fitting Options window as shown below. This form is instantiated via the Assay view available in the Aspen HYSYS oil manager.
In most circumstances, activating the Apply smart bulk fit... |
Problem Statement: In a column property view | Performance tab | Plots datasheet, and under Tray by Tray Properties, if we select Light/Heavy Key, and click on View Table button, we get Profile Table: Light/Heavy Key Profile dialog. Furthermore, if we click on Properties button located at the lower left corner, we get ... | Solution: First, we give a brief discussion of light and heavy keys in distillation column design. For binary distillation, the light key refers to the component with lower boiling point, and the heavy key is the second with higher boiling point. The concept can be used for multi-component mixtures. In these cases, we ... |
Problem Statement: TheCase Security option doesn't appear in Tools menu for the case protected with password but it appears for a new case or a case that it not password protected. Why? | Solution: You need a Master password to be able to access the Case Security features in a password protected case file. If you supply a user password instead of a master password, HYSYS will not show Case Security option to
the user.
When opening a case that is password protected, you have two options:
1) Enter the Use... |
Problem Statement: Why is the cooler duty not equal to mCp*DeltaT? | Solution: The heat flow in the cooler is calculated based on the enthalpy difference between the inlet and the outlet and not using the specific heat (cp). The enthalpy is calculated from the fluid state (Temperature, pressure and composition) using the specific property method selected. The calculated heat flow is the... |
Problem Statement: How is the reflux ratio defined in full reflux tower? | Solution: In case of total reflux, reflux ratio (RR) = R / V, where R is the reflux molar flow rate and V is the molar flow vapor rate.
Keywords: reflux ratio, total reflux
References: None |