Problem Statement: How to install Software License Manager (SLM) License Server?
Solution: This knowledge base article provides the installation steps for the SLM License Server application. AspenTech recommends to setup a seperate server (Physical, Virtual, or Cloud) to host SLM License Server. Please refer to the software and hardware specifications here. First, download the latest version of th...
Problem Statement: Is it possible to connect the GDOT Offline applications to the plant operations OPC server using GDOT Simulation Console?
Solution: Yes, it is possible. GDOT Offline is a subset of the capabilities of GDOT Online, nevertheless, GDOT Offline supports using OPC I/O tags and APC Gateway I/O tags. The point of GDOT Offline is for project engineers to test the behavior of the GDOT applications online. It is expected that the OPC servers and ...
Problem Statement: How to bulk change the Data Source for Aspen Process Explorer trend files?
Solution: Attached is a file called UpdateDataSourceTool.apx which needs to be run on the machine where all the apx. files are located. 1.- Double click on UpdateDataSourceTool.apx to open the file. 2.- Enter the folder path containing the apx. files to update, and enter the new Data Source name. Finally, click on Up...
Problem Statement: How to resolve the problem that Variables change in Excel is not displayed in Aspen Plus?
Solution: This can occur for one of two reasons: If you put an equation in a cell, the equation will take priority over any attempt to enter a new value on the form in Aspen Plus. Aspen Simulation Workbook expects you to change specified variables from Excel. To fix, close the form/dialog box in Aspen Plus; then, open ...
Problem Statement: What are the difference between Model Summary Grid and Flowsheet Summary in Aspen HYSYS?
Solution: We have two options for result reporting options: The Model Summary Grid displays input and results for material streams and unit operations in one view. - Includes an embedded, real-time link to Excel via Aspen Simulation Workbook. - In the main Model Summary Grid, the data appears split over separate tabs...
Problem Statement: How to change the form from T-XY diagram to YX diagram in Aspen Plus?
Solution: In order to change the following T-XY diagram: Please go the Results tab of the Analysis. Then, you will find the results table. On the right up corner there is a plot section, scroll down and you can choose the plot type from T-XY to Y-X. Therefore, the YX plot will generate based on the analysis results. ...
Problem Statement: How to import/export unit operations and flowsheet objects in Aspen HYSYS?
Solution: In HYSYS we can copy/paste flowsheet objects with n same file using below option: - Cut/Copy/Paste flowsheet object(s). Only user specified data is transferred. Accessed by right-clicking a highlighted object/objects. Most useful when doing a one-time transfer of data within a HYSYS simulation. Also, in HYSYS...
Problem Statement: Why Aspen Plus/Aspen Properties freezes/hangs when you initialize/run a model?
Solution: The investigation showed that all the effected users did not have access to cmd.exe (command prompt), which is required for Aspen Plus/Aspen Properties to initialize/run the simulation in the background. Affected users will need to request for grant permission to cmd.exe (command prompt) in order to initiali...
Problem Statement: All orders changed to Initiated status post Aspen Production Execution Manager (APEM) database upgrade
Solution: Post APEM database upgrade (done via database wizard) and recompilation of orders, we see all the past orders migrated from old system to new system in Initiated status. In the old flags.m2r_cfg config file the following key assignment is present “FINISH_ORDER_BY_PFC_FLOW = 0” but in the new one it is commen...
Problem Statement: This best practices article summarizes the recommendations given in KB Article 129045-2 (Configuring History Repositories for Optimal Performance).
Solution: 1. Create a dedicated Aspen InfoPlus.21 history repository for each distinct data source (i.e., every CIMIO server, Aspen Calc, calculated values from queries or external tasks, etc) to avoid placing data in older archives when forwarding stored Aspen Cim-IO data. 2. Create enough repositories so that n...
Problem Statement: Will Aspen Calc V11 (and later versions) work with the 64-bit version of Microsoft Excel 2016?
Solution: No. Aspen Calc is a 32-bit application and as a result can only work with other 32-bit applications. If the 64-bit version of Excel has been installed the best course of action would be to uninstall Excel and the Aspen products and then install the 32-bit version of Excel and then the Aspen products Keyword...
Problem Statement: SQL Return: SQL_ERROR Error Code: S1000 Error Message: [ORACLE] [ODBC] [Ora] ORA-28001: the password has expired
Solution: This error means that AORA Database Account Password used for the Client App ODBC Connections has expired. It is required to contact the Data Base Administrator to reset the password. Keywords: AORA Password References: None
Problem Statement: How to extract all instrument tags used by AORA?
Solution: You can extract the information using the Excel Add-In or with SQL queries written and executed either from AORA DBTools or from Query Writer within the SQL Server or Oracle RDB. Query example that will bring all the basic information (Tag Names, Tag Aliases and Instrument Type Identification): Select Dist...
Problem Statement: When running AORA the following error appears: SQL Return: SQL_ERROR Error Code: S0002
Solution: The error normally is caused by connection problems, verify the following: The Windows user has rights to read the AORA Database. The ODBC connection aims to the correct AORA database. The AORA database is not empty. Keywords: AORA S0002 References: None
Problem Statement: What is the name convention for the AORA reports?
Solution: All of the report filenames follow a specific naming convention, and this naming convention allows you to quickly determine the basic format for the report from the file name. The naming convention follows the following format: abbccddeef.rpt (The import table views have the same names as the corresponding im...
Problem Statement: What is the description of the Standard Reports provided by AORA?
Solution: The list of standard reports is subdivided into the following categories: Daily Reports Graphic Reports Monthly Reports Other Reports Views Reports Import Reports ERP Reports Planning Reports The attached pdf document contains the description of all the Standard Reports. Keywords: AORA AORA Reports Reference...
Problem Statement: When trying to run an SQLplus Report the following error is retrieved on Even Viewer Event code: 4010 Event message: An unhandled security exception has occurred.
Solution: Go to C:\ProgramData\AspenTech\, right click on SQLplus folder and go to the Security tab. Make sure that the user has the correct security permissions. If the user does not have Read & Execute permission, he/she will not be able to run a report. If the user does not have Modify permission, he/she will not be...
Problem Statement: How to create shortcuts in AORA?
Solution: In AORA, go to Tools and select Configure Tools. Click on Add, then enter a name in Tag and also in Hint. After click in the three dots […] to select a command or a batch script. For this example, DbTools.exe was selected. Finally click OK. Select Close and go back to Tools. You will see that the shortcut...
Problem Statement: Where can I find information about the batch commands used in AORA?
Solution: You can find more information about the batch commands in the Help File “aspeniiauhist.chm”. It is located in C:\Program Files (x86)\AspenTech\Advisor. Once you have opened that Help File, please go to “Running Aspen Operations Accounting Connect in Batch Mode” à “Batch Commands”. Keywords: AORA Batch Comma...
Problem Statement: When trying to connect to PI Historian, the following error appears: Error - PI Interface XXXXX: Historian connect failed: PI Interface: -1 Where XXXXX is the name of your interface.
Solution: PI Errors with a negative number, like “-1”, usually indicate communication problems between PI Server and AORA Connect machines. For these cases is it recommended to check: PI Trust Relationship between PI Server and AORA Connect machines. The PI-SDK software is installed correctly. Security Settings or Fir...
Problem Statement: Query example to move Transfer Records from one Logical Device to another.
Solution: The steps required to move a Transfer Record to another Logical Device are the following: Turn OFF the Transfer Record. Set the Transfer Record to Unusable. Change the IO_MAIN_TASK to the corresponding in the second Logical Device. Set the Transfer Record to Usable. Turn On the Transfer Record. In order to do...
Problem Statement: When using Excel Add-In the following error appears: Error:Invalid URI: The hostname could not be parsed.
Solution: Normally this happens after a migration of a server where the ADSA name was changed. This error means that the cell within the spreadsheet can not find the Data Source for which they were built at the beginning. Verify on your spreadsheet that the function is pointing to the right Data Source defined on ADSA...
Problem Statement: How to determine the Maximum Number of Components in a Principal Component Analysis?
Solution: The exact total number of components is not important for most methods including Principal Component Analysis (PCA); For this method it is important that you have enough components to explain the main variability in the data. Once the noise starts to be present on your results, then is an indicative of non-im...
Problem Statement: Where can I find Sustainability sample cases in Aspen HYSYS V12.1?
Solution: Aspen HYSYS V12.1 includes five new sample files to facilitate this objective. The new sample cases can be found by clicking the Examples button on the Resources ribbon and navigating to the Sustainability folder or by navigating to the examples folder (C:\Program Files\AspenTech\Aspen HYSYS V12.1\Samples\Sus...
Problem Statement: The problem is related to Version V12.1. The problem basically occurs when you create a DMC3 project on the server or network location that is going to be modified by different users. In this case, take for example User A who is the owner of the DMC3proj. file and is saved on location X. If User B ac...
Solution: TheSolution to this problem is related to the user permission to the location folder, subfolders, and files. basically, theSolution is to create projects in public folders that multiple users have read/write permissions in. If one of the users only has Read access the message will pop up and won’t allow the ...
Problem Statement: By Default, is not possible to Historize Controller User entries from the DMCplus or DMC3 Controller. However, this
Solution: presents a Workaround Using the capabilities of the IP21 Database to get a User Entry Historized. Solution The Following example was using an Example DMCplus controller named DEMCOL12, the following procedure is just to show the steps that must be done to have a User Entry historized and the Variables used in...
Problem Statement: How to modify the fixed area of a record by importing data from a .CSV file?
Solution: This query helps you to modify the fixed area of a record by a template in a .CSV file. First you have to create a .CSV in Excel with this structure: <Tag Name> <Field 1> <Field 2> .... <Field n> For this example, the description, engineering units, High high limit, high limit, low limit and low low lim...
Problem Statement: When you redeploy an RTE controller in V12.1, the Master Request and Status go to OFF without giving any warning or message when using the Warm Initialization option.
Solution: For previous versions, DMC3 Builder shows up a warning message saying that the controller must be turned OFF before redeploying when using the Warm Initialization option. In V12.1 you can redeploy with the MasterOnOffStatus ON, but you need to have an IO tag linked with the MasterOnOffRequest. In V14.0 the ...
Problem Statement: The Merge action allows joining two or more DMC3 applications in one application. This action keeps the applications Models, Cases, and Configurations from the previous application on the new one. However, there are a few tips to remember when you need to perform this action.
Solution: 1.- Import the application into one project that considers the main application. Also, do not affect this main application consider having a backup copy of this project. 2.- Check the list of options that you consider correct for the application. By default, the merge controllers window will allow you to Mer...
Problem Statement: Aspen HYSYS Dynamics – CCC Prodigy & Series 5 Emulator link
Solution: A HYSYS extension has been developed to create a link between Aspen HYSYS Dynamics and the CCC Emulator from Compressor Controls Corporation (links to both CCC Prodigy and S5 OPC Emulator are supported). The communication occurs through the OPC server that comes with the CCC Emulator. Further requirements and...
Problem Statement: How can the equilibrium of a reaction be controlled/specified in a RGibbs reactor? How do you restrict the equilibrium in the simulation? What is the temperature approach option in the equilibrium reaction, and how can it be used to modify the effluent composition from an equilibrium reactor? This op...
Solution: In RGibbs, you can restrict the chemical equilibrium with two Calculation options on the Setup | Specifications sheet: Restrict chemical equilibrium - specify temperature approach or reaction extents or Restrict chemical equilibrium - specify duty and temperature, and calculate temperature approach If you se...
Problem Statement: How to obtain the estimate for the equilibrium constant for an ionic reaction ? When ionic reactions are specified in the chemistry folder, the equilibrium constant can be specified by the user or it can be calculated internally by the Aspen Plus solver using the Gibbs free energies for reactants and...
Solution: The equilibrium constant, Keq, can be calculated using the activities and true mole fractions for the reactants and products as follows: In the attached file the following reaction has been generated in the chemistry folder If there are no specified values for the equilibrium constant, by default the equilibr...
Problem Statement: Docker Engine is the industry’s de facto container runtime that runs on various Linux and Windows Server operating systems. Aspen Mtell Maestro is a containerized application and requires Docker Engine on the environment on which it will be deployed. We have identified that many antivirus software (e...
Solution: This article contains some guidelines on how to approach this problem, however, the final reSolution most likely will depend on the antivirus software and it may be necessary to contact the antivirus vendor to request information about how the antivirus need to be configured on the machine with Docker Engine....
Problem Statement: How to delete the items in mMDM when the checkbox ‘show only deleted definitions’ is greyed out in mMDM Editor?
Solution: In some cases, it is noticed that the checkbox to show deleted definitions is not enabled. Normally this checkbox should be enabled. One case where it might not be enabled is when the user account is viewing the mMDM Editor as launched from the mMDM Bulk Load application. Please ensure that the user launches...
Problem Statement: aspenONE SLM License Manager Overview
Solution: The aspenONE SLM License Manager allows you to access various SLM features from a central location. To open the aspenONE SLM License Manager, from the Start menu, select aspenONE SLM License Manager On the aspenONE SLM License Manager, you can click the following buttons: Button Description Click the Con...
Problem Statement: How to manually back up Aspen Mtell database using SQL Server Management Studio
Solution: We recommend customer to schedule Aspen Mtell Database full backup everyweek. This article shows steps to take manual backup of Aspen Mtell Database. 1. Stop all Aspen Mtell services and close all Aspen Mtell applications. 2. Open Microsoft SQl Management studio 3. On the left, expand the databases section 4...
Problem Statement: How to backup a SQL Database on a regular schedule using Microsoft SQL Server Management Studio
Solution: This article will help you to take SQL Database backup on a regular schedule. These steps will create new backup files every time it runs the job. Create a SQL Server Agent Job Launch Microsoft SQL Server Management Studio and connect to the database Expand Management and right click Maintenance Plans and se...
Problem Statement: SQLplus takes a very long time to start (10-15 minutes). Once it starts, it works normally. The same thing occurs with AspenCalc.
Solution: This is a Framework Security configuration problem. To test this out, try adding n to the command line of TSK_SQL_SERVER in the InfoPlus.21 manager. The full command line should then be 10014 n. Then restart TSK_SQL_SERVER. This disables security in SQLplus. If this fixes the problem, you need to check the Fr...
Problem Statement: IQ Applications disappeared from PCWS and from the APCmanage application. From iq_manage.exe command prompt, it is possible to see that IQ applications were still running and writing values to the OPC. It is possible to have only the ACO and RTE applications running and visible in PCWS and the ACO a...
Solution: The root cause of this issue is that the Aspen APC Inferential Qualities Data Service was stopped for some reason, this service communicates the IQ server with the PCWS, but it is not responsible for the calculation engine of the IQ sensor itself. The Aspen APC Inferential Qualities Data Service needs to be ...
Problem Statement: Starting in V12.1, DMC3 Builder has a new feature of creating Deep Learning cases for CVs. However, after taking a snapshot of the online controller, you will notice that Deep learning case information is missing from the snapshot file. How can this case information be recovered?
Solution: This is a defect that will be fixed in the future release. This article provides the workaround for this issue: 1. Create a new Deep Learning case in the snapshot application 2. Then select current nonlinear CV as Master model output like the screenshot below and click OK. This will recover the current Maste...
Problem Statement: How can define Rated Capacity of a Centrifugal Pump given its calculated Normal capacity data via a Method script in ABE?
Solution: Rated Capacity of Centrifugal pump is not populated by simulators and User can calculate it via a Method that runs when Normal capacity of a Centrifugal pump is available. So, under the KBs folder one can add the Method .azkbs file under the directory: C:\AspenZyqadServer\Basic EngineeringXX.X\WorkspaceLibr...
Problem Statement: It is possible to install a GDOT Web Viewer in a different server than the GDOT Online one.
Solution: Using the Installation media, it is possible to install the GDOT Web Viewer components in a different server than the GDOT Online Server. The supported architecture for this functionality is having the SQL Server in the GDOT Online machine with the GDOT Databases, specifically GDOTOnlineHistory, already conf...
Problem Statement: How do I characterize a crude assay in Aspen HYSYS?
Solution: Characterization refers to the process in which limited input assay data is used in conjunction with estimation methods and other mathematical techniques to generate a “model” of the assay. The model allows properties to be calculated outside of the range of the available data to satisfy the needs of the plan...
Problem Statement: Why I am getting the outlet moisture content in decreasing trend while I increase the inlet feed moisture content, whereas ideally this should be opposite.
Solution: There might be a various issue like wrong inputs, wrong specifications in sensitivity analysis which may cause such errors. If everything is perfectly fine, then modify Sherwood Number, if using a very small Sherwood Number (0.01), you can get the expected phenomena. User shall check that the mass transfer ra...
Problem Statement: Does EDR calculates weights of Structures & Walkways for Air cooler?? if not why these details are available under Cost/Weight Table!!!...
Solution: The focus of this Air Cooler is to find thermal design, Aspen Air Cooler does not estimate the weight of structure, walkway, etc. It provides the estimated weight of bundle and side frame with tube support only. User shall check thoroughly all the estimated weights before finalizing the cost of exchanger. ...
Problem Statement: The value of Aeration factor multiplier in PetroFrac column is not changing. The bydefault value is 1. When user tries to change this value, could not change, it shows an error massage: ** ERROR IN THE BLOCK PARAGRAPH WHICH BEGINS ON LINE 117 BLOCK NAME: CDU MODEL NAME: PETROFRAC SKW: TRAY-RATE1...
Solution: Aeration factor is to tune or adjust the pressure drop. This is an adjustment factor to the aeration parameter β used in the calculation of pressure drop through the aerated liquid on a tray. Adjust this parameter to get better agreement between calculated and measured tray pressure drops. Default value is 1....
Problem Statement: This KB article explains why the GDOT DR
Solution: is affected by changing the QP target for a MV even if the QP weight is zero for that MV. Solution For DR, the “QP Target” field on a MV is actually used to wire in the process value, or in simulation mode the currently specified value (as if it were coming from the process). For the MV penalty term we are pe...
Problem Statement: What does Aspen Capital Cost Estimator considers as Support Personnel in the *.ccp evaluation report?
Solution: Support Personnel includes the costs assigned for secretarial, clerical, administrative, and accounting support in each engineering category. This concept can be found in the *.ccp report in the following fields: Procurement report Home office construction services Field office construction supervision...
Problem Statement: What is the Kinetic correlation option in a Sulsim Incinerator?
Solution: The Kinetic correlation requires that you enter the kinetic correlation. Aspen HYSYS uses this value to calculate the conversion of CO, H2, H2S, COS and CS2 in the incinerator because HYSYS includes the oxidation reactions of these components. So HYSYS uses the conversion equation when you specify the kinetic...
Problem Statement: I would like to view / customise the VBA code related to the Aspen Utilities Planner (AUP) plug-in for MS Excel. Where do I find this?
Solution: Like most plug-ins for MS Excel, the AUP plug-in is an *.xla attachment to the MS Excel application. When AUP is installed on a PC with MS Excel, this association should be made automatically. AUP will be available as a tab in the MS Excel ribbon. If this tab is not shown, it can be manually added to MS Exce...
Problem Statement: How can I find the Equipment Rental estimated for my Aspen Capital Cost Estimator project?
Solution: Aspen Capital Cost Estimator (ACCE) can generate and estimate the cost of Equipment Rental, such as cranes and trucks, which will be required during the construction of the facility. The Equipment Rental results can be found on the CCP report, searching for the label “EQUIPMENT RENTAL SUMMARY”: And on the Sta...
Problem Statement: What does the following information message mean: INFO > ' - 0' SOIL TYPE NOT SPECIFIED ?
Solution: The INFO you are receiving is an informational message and it won't prevent your estimate from completing. The Civil/Steel specs in the Project Basis View is where you may set the soil type. Keywords: Info, message, soil, type References: None
Problem Statement: Why does the Equilibrium reactor predict carbon formation while the Gibbs Reactor does not?
Solution: Aspen HYSYS Component Database has only one kind of carbon. Carbon presents itself as different allotropes, such as C1 (Carbon-Graphite), C2 (Carbon-Diatomic Gas), C3 (Carbon Triatomic Gas), C-D (Carbon-Diamond) etc. Each one corresponds to a different free energy state. The carbon atom contained in Aspen HYS...
Problem Statement: Can I enter pressures greater than 1000 bar or 14503.8 psi for my heat exchangers in Aspen Exchanger Design and Rating (EDR)?
Solution: Currently, Aspen Exchanger Design and Rating does not support simulations with pressures larger than 1000 bar (14503.8 psi). Reason: EDR must be generic with respect to different shell and tube exchanger configurations and include a variety of physical effects such as entry length effects, natural convection...
Problem Statement: How to create a Put Transfer record in Aspen InfoPlus.21?
Solution: 1. Open the Aspen InfoPlus,21 Admnistrator. 2. Expand your Logical Device name under Cim-IO and highlight Put Transfers 3. Right click on Put Transfers and select New record defined by IoPutDef: 4. Name the new Put Transfer record (up to 24 characters). Put_Test in this example. 5. You will receive the erro...
Problem Statement: When configuring a new Cim-IO interface manually and trying to configure a transfer record in the Aspen InfoPlus.21 Administrator, the error No Such Record is displayed when the Main Task from that new interface (TSK_M_XXX) is set up in the IO_MAIN_TASK field.
Solution: The root cause of the issue is that the Main Task has not been added to the IoExternalTskDef Defintion Record. In order to fix the issue, go to the record IoExternalTskDef, then right click on it and select New Record Defined by IoExternalTskDef. Name it with its corresponding Main Task name (TSK_M_XXX). On...
Problem Statement: Aspen Mtell client is unable to load and view tags from an online historian through System Manager--> Sensor Data Sources--> Map Sensors, whereas the Aspen Mtell application server is connected and able to browse tags. Users get the error message below: Unable to load tags. Unexpected character enc...
Solution: This generally occurs in newly installed Aspen Mtell client applications. The Aspen Mtell application server may be connected to the historian and able to browse tags, but the client machine gives the above error. When this happens it is likely because the Adapter URL on the client is pointing to the wrong m...
Problem Statement: How do I estimate an incinerator?
Solution: You may use the Quoted Equipment component to estimate an incinerator. A built-in incinerator component is not available. Please note the system does have a default Code of account (COA) value of 253 for incinerators. You may also create and store cost data for incinerators in the Equipment Model Library. Ke...
Problem Statement: How is electrical tracing of piping calculated?
Solution: The length of the tracing cable is calculated based on the pipe length and diameter. There are two types of electrical tracing: 1) E-PRO to maintain at the process temperature, and 2) E-AMB to maintain at ambient temperature. The heat loss of the pipe is compensated by using electrical tracing cable. ACCE d...
Problem Statement: What is the maximum number of steel structures in an area?
Solution: The maximum number of steel structures in an area is 10. The 11th will give you the following error message: If you have more than 10 steel structures, then note that you may add additional areas as needed. As a reminder, you may add steel structures to areas from the Components tab | Plant bulks | Steel...
Problem Statement: When attempting to import an Excel spreadsheet into Aspen Flare System Analyzer, I am receiving an import error. I then get a message, Sorry, this function doesn't support excel file which is generated or edited by Excel2010. I am not using Excel2010, so why am I getting this error? How do I fix i...
Solution: Before exporting the original Flare file to Excel (.xls or .xlsx), first export to .xml and then import the .xml file to generate a fresh copy of the Flare model. This procedure can, in effect, clean up the Flare file. Once the .xml file has been successfully imported and the fresh flare model is available,...
Problem Statement: Where can I find the default Construction Workforce Wage Rates?
Solution: The default Construction Workforce Wage Rates may be found in the Aspen Icarus Keywords: Wage Rates, Craft, Construction References: Manual, Chapter 30, Field Manpower Titles and Wage Rates. The reference manual may be accessed from Help | Documentation | Icarus Reference.
Problem Statement: Why am I getting the warning, MABP exceeds the relieving pressure when I click the Check Model button?
Solution: This warning alerts the user that the Allowable Backpressure (Control Valve Editor | Conditions tab) is set higher than the Inlet (Relieving) Pressure. To resolve this warning, ensure the Inlet Pressure is higher than the Allowable Backpressure. Keywords: MABP, inlet, relieving, pressure, exceed, allowable, ...
Problem Statement: How does the system handle separate productivity sets for craft and workforce?
Solution: The workforce productivity establishes the default for all crafts, and may be useful for high-level estimates. The craft productivity overrides this default and may be specified craft-by-craft, improving accuracy for a detailed estimate. The system does not compound the workforce and craft productivity. Pr...
Problem Statement: How do I specify a variable speed (frequency) drive (VFD)?
Solution: Option 1: For pumps and other applicable components, you will find a Driver type option which you can change from Motor (default) to VFD. Option 2: Under Process Equipment | Motors, there is a TEFC Motor with variable speed drive. Option 3: Lastly, you could create a variable speed drive as a quoted equipme...
Problem Statement: Why Empty K-Values on Aspen HYSYS Material Stream?
Solution: Aspen HYSYS V11, The Worksheet tab | K Value page on the Material Stream property view displays the K values or distribution coefficients for each component in the stream. A distribution coefficient is a ratio between the mole fraction of component i in the vapor phase and the mole fraction of component i in ...
Problem Statement: When installing GDOT Unified the first time, it requires creating some databases and check on them on SQL. Additionally, SQL is requiring for the history and data collection for GDOT application. However, there could be some connectivity problem on the Database and additionally, the connection to the...
Solution: The Unified Agent Service basically requires another important service to start which is the SQL Server Service (the name of the server will depend on the version). Every time to start the server or reboot the server make sure that the SQL Server service is running. This service requires a Local Administrato...
Problem Statement: When launching Aspen GDOT Unified the first time or after an upgrade and all Database has been already configured Error 403.1 may appear instead of the Home page or the login prompt.
Solution: The way to fix this problem is simply by changing the feature permissions from the handler mappings feature from IIS. To apply the change, apply the next steps: 1.- On Windows Start look for the application IIS Manager 2.- Once is open, on the left side three open Default Web Site > AspenTech > AspenUnifie...
Problem Statement: GDOT can present different
Solution: Status, please find a quick description on the table below: However, is not mentioned what couldSolution Status 4 could mean. ThisSolution frames a description of what theSolution Status 4 stands for. Solution ASolutionStatus of 4 in GDOT usually means Skipped which means that the execution cycle skipped. Ty...
Problem Statement: The CLC files are basically Data Collection files that contain MV and CV vector information generated during normal operation or Step Testing. This information is required to run Model-identification on DMC3 Builder or DMCplus model. This
Solution: frames the information contained in the CLC header. Solution A Normal CLC file would look like this: The file is divided basically into three sections: the header, the Vector names and description, and the Data collecting showing Data/ Value/ Quality Status. The header section displays the following informa...
Problem Statement: Additional filesets can be created in the AW IP21 Administrator. However, it should be notice that the default location for the AW fileset may be different from the one used for an independent IP21 Administrator, and this location may require further security privilege. When these privileges do not e...
Solution: TheSolution basically requires granting the correct permission for the account used to manage the IP21 Administrator. There are some important things to check: 1.- Check the directory where the file sets will be added. You can refer to the current fileset on IP21 administrator to check the correct path. On t...
Problem Statement: Docker Engine Enterprise and Docker Compose quick installation and upgrade guide for Windows Server when internet connection is not available on the host machine.
Solution: This article will explain how to install and upgrade Docker Engine Enterprise and Docker Compose on a machine without internet connection. Prerequisites Installation: A second machine with internet connection to download attached files. Host machine should have Windows Server 2019 OS (version 1809 or higher)...
Problem Statement: This
Solution: provides a way to run different and multiple cases for a DMC3 Builder project. Solution The Model Structure of a DMC3 Builder is basically divided into two parts: Master Model and Case Folders. Inside of these Case Folders, we can create multiple cases with different vectors, parameters trials, datasets, etc....
Problem Statement: This
Solution: just frames the process of Import Tag Template. Attached the equivalent Tag Templates that exist on DMCplus Build for DMC3 builder. Solution Tag Templates basically work to modify and create multiple tag names for multiple variables. These are particularly useful to update and change the tag names of the cont...
Problem Statement: This
Solution: presents a quick guide on how can IP21 tags can be read to the IQconfig. file Solution Please find on the attached PDF the details on how to set the IQconfig. File to read values from IP21. Keywords: IQ, IP21 References: None
Problem Statement: The Scheduled “Autorun” operations for PID groups explicitly use the default “SQLplus on localhost” ODBC connection, which Is created by the AspenWatch server software installation. When the ODBC connection is not properly setting this can lead to problems as PCWS not showing results under PID loop a...
Solution: To solve this issue, it is necessary to create an additional ODBC connection on the AspenWatch Server. This connection can be identical to the existing one, except replacing the ODBCS data Source with the name “SQLplus on localhost” The new ODBC connection should look as it follows: ODBC Data Source Name: SQL...
Problem Statement: How to develop a First Principles Driven Hybrid Model for Heat Exchanger Fouling?
Solution: Heat Exchanger Fouling can change with time and process conditions. Building a customized model can be challenging and often requires require significant time and effort, and additional costs. OneSolution is to build a predictive heat exchanger model and incorporate historical data from the heat exchanger to...
Problem Statement: Retrieve Parameters option is not working as designed in V12.1. In V12.1: Retrieve parameters with Copy pure component parameter to input CHECKED, the source will be PURE39 and USER-PURE39 is in the source list. Retrieve parameters with Copy pure component parameter to input UNCHECKED, the source ...
Solution: The correct behavior is as follows: When Retrieve parameters with Copy pure component parameter to input CHECKED, the source will be USER-PUREXX, and it will apply to all components in the list, not just newly added components. When Retrieve parameters with Copy pure component parameter to input UNCHECKED, th...
Problem Statement: Does aspenONE software support Office 2021?
Solution: Office 2021 has been tested on all aspenONE V12.x software and will support aspenONE V12.x released software. Keywords: Office 2021 support References: None
Problem Statement: Does aspenONE software support Windows 11 Operating System?
Solution: Windows 11 operating system has been tested on all aspenONE V12.x and V11.x software and will support aspenONE V12.x and aspenONE V11.x released software. Note: Aspen Unified in V11 does not support Windows 11. Keywords: Windows 11 support References: Known Issue: Windows 11 with V11.x with Aspen Properties:...
Problem Statement: What is the arc.byte file used for? It always seems to be 128 KB in size.
Solution: The file arc.byte is part of an Aspen InfoPlus.21 history file set. A file set consists of three files - the other two are arc.key and arc.dat. (SeeSolution 000077763 for an explanation of arc.key.) An occurrence of trend data in a record defined by IP_AnalogDef or IP_DiscreteDef is 15 bytes in size holding...
Problem Statement: This knowledge base article describes the behavior of Aspen InfoPlus.21 when the historian file, tune.dat, has become corrupted, but is still in a usable state, or if the parameters in the tune.dat have been set to zero.
Solution: 1) The following Aspen SQLplus statement returns no rows. Select occnum, fs_start_time from DiskHistoryDef where name=TSK_DHIS; 2) In the Aspen InfoPlus.21 Administrator the column % Full shows 0.00 for each existing fileset. 3) In the Aspen InfoPlus.21 Administrator the History Parameters shows 0 and 0...
Problem Statement: Thermodynamic states the relation between enthalpy (h), Gibbs energy (g) and entropy (s): g = h - T * s (where T is the absolute temperature). When checking the stream results in conventional solid substream, one can observe the relation is not satisfied. Why?
Solution: When reporting the default stream property solid SMX for a stream, whether in the MIXED or CISOLID substream, we calculate the property as a mole-average of the solid species, because Aspen Plus handles solids as pure phases, not as solidSolutions. The value is correct. When reporting the prop-set property s...
Problem Statement: What does equipment material cost include? What does it not include?
Solution: Equipment material cost includes the following: Cost of the parts of the equipment, such as internals, shell, nozzles, manholes, covers, etc. Fabrication labor (shop and/or field) Shop and office overhead Vendor engineering, shop drawings, shop testing, certification, typical manuals, small tools, and accesso...
Problem Statement: Why is there no effect on my piping costs when I add a Rupture Disk to my Above grade or buried pipe component?
Solution: A Rupture Disk (RD) is considered an instrumentation cost (COA 683), so its cost is associated with instrumentation. Keywords: piping, rupture disk, RD, instrumentation, COA 683 References: None
Problem Statement: What are the Design gauge pressure Inlet and Outlet fields for the compressor setup? What information are these fields requesting?
Solution: These fields are requesting the design (not operating) gauge pressure of the gas entering the compressor (low pressure) and exiting the compressor (high pressure). Typically, the design inlet and outlet pressures includes a safety factor over the operating pressures. For instance, for the compressor modeled...
Problem Statement: How can I estimate Orifice Plates?
Solution: One way to estimate an orifice plate is to add an Above grade or buried pipe component and include the fitting OP | Orifice plate and union and its quantity. Set the pipe diameter as needed and note the minimum pipe length is 1 ft. Alternatively, you may use the Equipment or Unit Cost Libraries to store th...
Problem Statement: How do you send all welds to shop for all equipment at once?
Solution: Construction management cost is part of Indirect. By default, Engineering management and Construction management fields are blank. To drive generation of estimated of engineering and construction management costs, a contractor MUST be specified. If there is no line item in the output report for Code of Accoun...
Problem Statement: Can you link cost variables from Aspen Process Economic Analyzer (APEA) to Aspen PLUS Dynamics or Aspen HYSYS Dynamics?
Solution: No, you cannot link cost variables from APEA to Aspen PLUS Dynamics or Aspen HYSYS Dynamics. Cost analysis using APEA is supported for steady state mode only. Keywords: Cost Variables, Cost Variables Linking References: None
Problem Statement: On the General Wage Rate/Productivity-IP Box under Project Basis View, I entered manually all the Craft Wage Rates for all the craft code. Now I need to reduce the wages by a percentage (%). Instead of revising all the wages, is it a possibility to just reduce the wages by a percentage basis?
Solution: Yes, it is possible to reduce the wage rates in one field. This however requires creating a new construction workforce (CWF). Let's say, CWF #1 was created previously, where the craft wage rates are defined. Now, create a second CWF and adjust the craft wage rates as a percentage of CWF #1 as follows: Note...
Problem Statement: I have been trying to access the Aspen Custom Modeler (ACM) example files. But every time I open any file, I get a blank flowsheet and a message similar to this, Failed to load file C:\Program Files (x86)\AspenTech\Aspen Custom Modeler V10.0\Examples\Absorber\Absorber.acmf, working directory is in us...
Solution: This problem happens because the Allow setting of working folder location is unchecked. To resolve this error, check the Allow setting of working folder location option under Tools > Settings > Preferences. Keywords: Working folder, Example files, ACM References: None
Problem Statement: Why does changes to the Total Construction Weeks change the Total Project Costs?
Solution: The construction schedule is integrated with the cost estimate to provide the basis for estimation of schedule-dependent costs such as equipment rental requirements, field supervision and construction management. Because of this dependence, changing construction weeks will impact the project total costs. Add...
Problem Statement: How do I create a Code of Account (COA) exception and when should it be used?
Solution: Consider a scenario where you want to allocate fittings on a pipe, such as valves and bolt-up connections, to a different COA other than pipe erection. This can be accomplished by creating exceptions in the Code of Account. In this example, to allocate these to a different COA, you will have to create excepti...
Problem Statement: How can I override Procurement and Home office expenses in Basic engineering?
Solution: Overriding Procurement in Basic Engineering 1. Go to Project Basis - Engineering Workforce - By Phase. 2. Add another column. 3. Engineering Workforce number - Specify EWF 1. 4. Engineering Phase - Specify P (Procurement). 5. Engineering hours - specify 0. 6. Engineering ...
Problem Statement: Is there something to consider for leaving the equipment as it is? This is not demolition, this is a component already present in the project but does impact the cost because of the connections and so on that will be different.
Solution: For an existing equipment, select “EXIS” as the installation option field of the component. For additional cost associated with this component, you can then use the “Mat’l/ man-hours additions” form from the “Options” drop down menu. Other installation options are explained on article 97099. Keywords: Exist...
Problem Statement: How do you send all welds to shop for all equipment at once?
Solution: There is no direct way to send all welds to shop. You can select “RMT” in the project basis view but if the length exceeds the limit, some of the weld will be done in the field. However, for each piping component, you can put 100% in the “Percent of welds in Shop” under Options > Pipe -Item Details. Keywords...
Problem Statement: When I change Percent calculated hours for Home office construction services, under Engineering Workforce | By Phase, it seems to have no effect.
Solution: Home office (HO) construction services are calculated based on the engineering workforce (EWF) performing the task. To capture any customization of costs for home office construction services, the EWF needs to be linked for the contractors doing the installation (see below). Otherwise, the system is going to...
Problem Statement: How to get equipment footprints data from Aspen Capital Cost Estimator (ACCE)?
Solution: To get the equipment footprint data on ACCE, please follow the steps below - 1. Turn on the equipment footprint from Equipment Specs form: 2. Evaluate the project and Run the Design and Basis Reports > Components >(component type- pumps, compressors etc.) Report to get the equipment footprints: Keywords: Eq...
Problem Statement: How do I restore the missing tabs in the palette window and Project Basis View forms?
Solution: After the installation of Aspen Capital Cost Estimator (ACCE) V8.0 and above, the user is required to check whether the resiliency (configuration for first time use) is successful. Default folders and shortcut under My Documents will be created and if resiliency fails to set-up these folders properly, users m...
Problem Statement: Why does Datasheet Definer Tab disappear in Excel? In some occasions, when I open Datasheet Definer I am getting the following error message: Note: If the Datasheet Definer Ribbon is unavailable after a recent installation of Aspen Basic Engineering, the ABEDefinerAddIn may NOT be loaded yet. To f...
Solution: If you are seeing this error message or not able to display the Datasheet Definer tab, make sure that AZDatasheetDefiner Add-In is not disabled in Excel options. Excel can disable an Add-In if the trust or security settings enabling it to run were not previously set, or if Excel is terminated by the Task Mana...