ac | Haier | F43 | null | null | Model matching abnormality | null | https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml | 2026-10-27 | https://faultdecode.com/ac/haier/#code-f43 |
ac | Haier | FE | null | null | Fixed frequency AC: refrigerant leaking detection malfunction | null | https://www.haier.com/pk/service-support/self-service/20160120_103780.shtml https://www.haier.com/ph/service-support/self-service/20250311_257059.shtml https://www.haier.com/tz/service-support/self-service/20230814_213063.shtml | 2026-10-27 | https://faultdecode.com/ac/haier/#code-fe |
solar-pump | INVT | OUt1 | fault type 1 | GD100-PV | Inverter unit U-phase protection | Acceleration too fast, IGBT module damaged, interference, poor drive wire connection, or a short to ground. INVT: increase ACC time, check drive wires and interference; replace the power unit if damaged. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-out1 |
solar-pump | INVT | OUt2 | fault type 2 | GD100-PV | Inverter unit V-phase protection | Same causes and fixes as OUt1. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-out2 |
solar-pump | INVT | OUt3 | fault type 3 | GD100-PV | Inverter unit W-phase protection | Same causes and fixes as OUt1. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-out3 |
solar-pump | INVT | OV1 | fault type 7 | GD100-PV | Overvoltage during acceleration | Input voltage abnormal, large energy feedback, no braking components, or dynamic brake disabled (INVT gives the same causes for OV1, OV2 and OV3). INVT: check the input power, check whether the DEC time is too short or the inverter starts while the motor is turning, install braking components, check related settings. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-ov1 |
solar-pump | INVT | OV2 | fault type 8 | GD100-PV | Overvoltage during deceleration | Same causes and fixes as OV1. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-ov2 |
solar-pump | INVT | OV3 | fault type 9 | GD100-PV | Overvoltage during constant speed running | Same causes and fixes as OV1. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-ov3 |
solar-pump | INVT | OC1 | fault type 4 | GD100-PV | Overcurrent during acceleration | Acceleration or deceleration too fast, low grid voltage, inverter power too low, abnormal load, short to ground or output phase loss, strong interference, or overvoltage stall protection disabled. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-oc1 |
solar-pump | INVT | OC2 | fault type 5 | GD100-PV | Overcurrent during deceleration | Same causes as OC1. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-oc2 |
solar-pump | INVT | OC3 | fault type 6 | GD100-PV | Overcurrent during constant speed running | Same causes as OC1. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-oc3 |
solar-pump | INVT | UV | fault type 10 | GD100-PV | Bus undervoltage | Grid voltage too low or overvoltage stall protection disabled. INVT: check the grid input power and related settings. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-uv |
solar-pump | INVT | OL1 | fault type 11 | GD100-PV | Motor overload | Grid voltage too low, motor rated current set wrong, or motor stall or sudden load change. INVT: check the grid voltage, reset the motor rated current, check the load and adjust torque boost. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-ol1 |
solar-pump | INVT | OL2 | fault type 12 | GD100-PV | Inverter overload | Acceleration too fast, a rotating motor was reset, grid voltage too low, load too heavy, or motor power too small. INVT: increase ACC time, avoid restarting right after a stop, check the grid voltage, select a larger inverter or a proper motor. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-ol2 |
solar-pump | INVT | SPI | fault type 13 | GD100-PV | Phase loss on the input side | Phase loss or violent fluctuation on input R, S, T. INVT: check input power and installation wiring. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-spi |
solar-pump | INVT | SPO | fault type 14 | GD100-PV | Phase loss on the output side | Phase loss on U, V, W, or the three load phases are seriously unequal. INVT: check output wiring, motor and cable. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-spo |
solar-pump | INVT | OH1 | fault type 15 | GD100-PV | Rectifier module overheating (P07 list: boost module overheat) | Air duct blocked or fan damaged, ambient temperature too high, or overload for too long. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-oh1 |
solar-pump | INVT | OH2 | fault type 16 | GD100-PV | Inverter module overheat | Same causes as OH1. INVT: clear the vent duct or replace the fan, lower the ambient temperature. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-oh2 |
solar-pump | INVT | EF | fault type 17 | GD100-PV | External fault | An external fault input terminal (SI) acted. INVT: check the external device input. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-ef |
solar-pump | INVT | CE | fault type 18 | GD100-PV | RS485 communication fault | Wrong baud rate or address, wiring fault, or strong interference. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-ce |
solar-pump | INVT | ItE | fault type 19 | GD100-PV | Current detection fault | Control board connector loose, Hall device damaged, or amplifier circuit fault. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-ite |
solar-pump | INVT | tE | fault type 20 | GD100-PV | Motor autotuning fault | Motor capacity does not match, motor parameters set wrong, autotuned values far from standard, or autotuning timed out. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-te |
solar-pump | INVT | EEP | fault type 21 | GD100-PV | EEPROM operation fault | Error reading or writing control parameters, or EEPROM damaged. INVT: press STOP/RST; change the main control board if it stays. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-eep |
solar-pump | INVT | PIDE | fault type 22 | GD100-PV | PID feedback disconnection | PID feedback signal wire disconnected or the feedback source is gone. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-pide |
solar-pump | INVT | bCE | fault type 23 | GD100-PV | Braking unit fault | Listed in the fault record (P07.27) only; no cause given in the fault table. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-bce |
solar-pump | INVT | END | fault type 24 | GD100-PV | Running time reached | The inverter has run longer than its internal set running time. INVT: ask the supplier to adjust the preset running time. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-end |
solar-pump | INVT | OL3 | fault type 25 | GD100-PV | Electronic overload | Overload pre-alarm reached the set threshold. INVT: check the load and the overload pre-alarm threshold. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-ol3 |
solar-pump | INVT | ETH1 | fault type 32 | GD100-PV | To-ground short-circuit fault 1 | Inverter output is shorted to ground. INVT: check the motor wiring. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-eth1 |
solar-pump | INVT | ETH2 | fault type 33 | GD100-PV | To-ground short-circuit fault 2 | Fault in the current detection circuit. INVT: replace the Hall device or change the main control board. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-eth2 |
solar-pump | INVT | dEu | fault type 34 | GD100-PV | Speed deviation fault | Load too heavy or stalled. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-deu |
solar-pump | INVT | STo | fault type 35 | GD100-PV | Mal-adjustment fault | SM control parameters wrong, autotuned parameters not accurate, or the inverter is not connected to the motor. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-sto |
solar-pump | INVT | LL | fault type 36 | GD100-PV | Electronic underload | Underload pre-alarm reached the set threshold. INVT: check the load and the underload pre-alarm threshold. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-ll |
solar-pump | INVT | tSF | fault type 37 | GD100-PV | Hydraulic probe damage | The hydraulic (water level) probe is damaged. INVT: replace the probe. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-tsf |
solar-pump | INVT | PINV | fault type 38 | GD100-PV | PV reverse connection fault | Solar panel (PV) wiring is reversed. INVT: swap the positive and negative wiring and wire it again. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-pinv |
solar-pump | INVT | PVOC | fault type 39 | GD100-PV | PV overcurrent | ACC or DEC too fast, inverter power too low, abnormal load, or short to ground. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-pvoc |
solar-pump | INVT | PVOV | fault type 40 | GD100-PV | PV overvoltage | Solar panel input voltage too high, or model -4 set as another model. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-pvov |
solar-pump | INVT | PVLV | fault type 41 | GD100-PV | PV undervoltage | Too little panel power in series, cloudy or rainy weather, or motor starting current too high. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-pvlv |
solar-pump | INVT | E-422 | fault type 42 | GD100-PV | Fault on 422 communication with the boost module | The four 422 communication cables are in poor contact. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-e-422 |
solar-pump | INVT | OV | fault type 43 (boost side) | GD100-PV | Bus overvoltage detected on the boost side | Sunlight changes sharply. INVT: adjust the boost PI parameters and increase P19.07 and P19.08. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-ov |
solar-pump | INVT | A-LS | alarm | GD100-PV | Weak-light pre-alarm (not a fault) | Sunlight is weak or the panel setup is too small. The pump sleeps and restarts by itself when light is enough. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-a-ls |
solar-pump | INVT | A-LL | alarm | GD100-PV | Underload pre-alarm (not a fault) | The pumping pool (well or tank) has no water. INVT: check the pumping pool. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-a-ll |
solar-pump | INVT | A-tF | alarm | GD100-PV | Full-water pre-alarm (not a fault) | The pool or tank is full. With the full-water function set up, the pump stops after a delay; otherwise check the level terminal wiring. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-a-tf |
solar-pump | INVT | A-tL | alarm | GD100-PV | Empty-water pre-alarm (not a fault) | The pool has no water. With the empty-water function set up, the pump stops after a delay; otherwise check the level terminal wiring. | https://www.invt.com/uploads/file1/20220622/GD100-PV-Series-VFD-Manual_V1.7.pdf | 2026-10-27 | https://faultdecode.com/solar-pump/invt/#code-a-tl |
ac | Onida | EE | outdoor 25 flashes | Inverter (2026 manual, selected models) | Indoor unit EE fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-ee |
ac | Onida | E1 | outdoor 26 flashes | Inverter (2026 manual, selected models) | Indoor fan fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-e1 |
ac | Onida | E2 | outdoor 27 flashes | Inverter (2026 manual, selected models) | Indoor fan zero-crossing detection fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-e2 |
ac | Onida | E3 | outdoor 28 flashes | Inverter (2026 manual, selected models) | Indoor coil temperature sensor fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-e3 |
ac | Onida | E4 | outdoor 29 flashes | Inverter (2026 manual, selected models) | Indoor ambient temperature sensor fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-e4 |
ac | Onida | E0 | outdoor 1 flash | Inverter (2026 manual, selected models) | Outdoor unit EE fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-e0 |
ac | Onida | E6 | outdoor 2 flashes | Inverter (2026 manual, selected models) | Indoor and outdoor unit communication fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-e6 |
ac | Onida | F1 | outdoor 4 flashes | Inverter (2026 manual, selected models) | Compressor starting abnormal | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-f1 |
ac | Onida | F2 | outdoor 5 flashes | Inverter (2026 manual, selected models) | Compressor drive fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-f2 |
ac | Onida | F3 | outdoor 6 flashes | Inverter (2026 manual, selected models) | IPM module fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-f3 |
ac | Onida | F4 | outdoor 7 flashes | Inverter (2026 manual, selected models) | Compressor shell top fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-f4 |
ac | Onida | F5 | outdoor 8 flashes | Inverter (2026 manual, selected models) | Discharge temperature sensor fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-f5 |
ac | Onida | F6 | outdoor 9 flashes | Inverter (2026 manual, selected models) | Suction temperature sensor fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-f6 |
ac | Onida | F7 | outdoor 10 flashes | Inverter (2026 manual, selected models) | Outdoor coil temperature sensor fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-f7 |
ac | Onida | F8 | outdoor 11 flashes | Inverter (2026 manual, selected models) | Outdoor ambient temperature sensor fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-f8 |
ac | Onida | F9 | outdoor 12 flashes | Inverter (2026 manual, selected models) | Outdoor DC fan fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-f9 |
ac | Onida | P1 | outdoor 13 flashes | Inverter (2026 manual, selected models) | Outdoor unit AC current protection | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-p1 |
ac | Onida | P2 | outdoor 14 flashes | Inverter (2026 manual, selected models) | Compressor phase current protection | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-p2 |
ac | Onida | P3 | outdoor 15 flashes | Inverter (2026 manual, selected models) | Outdoor unit AC voltage too high or too low (protection) | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-p3 |
ac | Onida | P4 | outdoor 16 flashes | Inverter (2026 manual, selected models) | DC overvoltage or undervoltage protection | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-p4 |
ac | Onida | P5 | outdoor 17 flashes | Inverter (2026 manual, selected models) | IPM overheat protection | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-p5 |
ac | Onida | P6 | outdoor 18 flashes | Inverter (2026 manual, selected models) | Discharge temperature overheat protection | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-p6 |
ac | Onida | P7 | outdoor 19 flashes | Inverter (2026 manual, selected models) | Indoor coil anti-freezing protection in cooling | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-p7 |
ac | Onida | P8 | outdoor 20 flashes | Inverter (2026 manual, selected models) | Outdoor coil overheat protection in cooling | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-p8 |
ac | Onida | P9 | outdoor 21 flashes | Inverter (2026 manual, selected models) | Indoor coil overheat protection in heating | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-p9 |
ac | Onida | PC | outdoor 22 flashes | Inverter (2026 manual, selected models) | Outdoor temperature too low for cooling (protection) | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-pc |
ac | Onida | PH | outdoor 23 flashes | Inverter (2026 manual, selected models) | Outdoor temperature too high for heating (protection) | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-ph |
ac | Onida | L1 | outdoor 31 flashes | Inverter (2026 manual, selected models) | Drive bus voltage too high (protection) | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-l1 |
ac | Onida | L2 | outdoor 32 flashes | Inverter (2026 manual, selected models) | Drive bus voltage too low (protection) | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-l2 |
ac | Onida | L3 | outdoor 33 flashes | Inverter (2026 manual, selected models) | Drive phase current overload fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-l3 |
ac | Onida | L4 | outdoor 34 flashes | Inverter (2026 manual, selected models) | Phase current sampling abnormal | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-l4 |
ac | Onida | FC | outdoor 35 flashes | Inverter (2026 manual, selected models) | Filter clean reminder (not a fault). Onida: press SLEEP 4 times within 8 seconds to reset | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-fc |
ac | Onida | EB | null | Inverter (All Models manual) | Outdoor communication fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-eb |
ac | Onida | F2 | null | Inverter (All Models manual) | Compressor out-of-step fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-f2-2 |
ac | Onida | EE | null | Fixed speed (2026 manual) | Indoor unit EE fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-ee-2 |
ac | Onida | E1 | null | Fixed speed (2026 manual) | Indoor fan fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-e1-2 |
ac | Onida | E3 | null | Fixed speed (2026 manual) | Indoor coil temperature sensor fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-e3-2 |
ac | Onida | E4 | null | Fixed speed (2026 manual) | Indoor ambient temperature sensor fault | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-e4-2 |
ac | Onida | P7 | null | Fixed speed (2026 manual) | Indoor coil anti-freezing protection in cooling | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-p7-2 |
ac | Onida | E1 | alternates with set temperature every 4 seconds | Fixed speed (All Models manual) | Room sensor short or open | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-e1-3 |
ac | Onida | E2 | alternates with set temperature every 4 seconds | Fixed speed (All Models manual) | Coil sensor short or open | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-e2-2 |
ac | Onida | E5/H6 | null | Fixed speed (All Models manual) | Fan motor error | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-e5-h6 |
ac | Onida | dF | null | Fixed speed (All Models manual) | Defrost error | null | https://onida.com/wp-content/themes/onida/pdf/ONIDA-User-Manual-2026-_R4-07102026_compressed.pdf https://onida.com/wp-content/themes/onida/pdf/User-Manual-Air-Conditioner-All-Models.pdf | 2026-10-28 | https://faultdecode.com/ac/onida/#code-df |
ac | Mitsubishi Electric | 1 flash | upper operation lamp, every 0.5 s | FAQ flash table | Room temperature thermistor short or open circuit | null | https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysi... | 2026-10-28 | https://faultdecode.com/ac/mitsubishi/#code-1-flash |
ac | Mitsubishi Electric | 2 flashes | upper operation lamp, then 2.5 s off | FAQ flash table | Indoor coil thermistor short or open circuit | null | https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysi... | 2026-10-28 | https://faultdecode.com/ac/mitsubishi/#code-2-flashes |
ac | Mitsubishi Electric | 3 flashes | upper operation lamp, then 2.5 s off | FAQ flash table | Serial signal (Mitsubishi lists the condition as no fan speed feedback signal during indoor fan operation) | null | https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysi... | 2026-10-28 | https://faultdecode.com/ac/mitsubishi/#code-3-flashes |
ac | Mitsubishi Electric | 4 flashes | upper operation lamp | Inverter only (FAQ flash table) | Indoor fan motor (Mitsubishi lists the condition as indoor PCB failure) | null | https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysi... | 2026-10-28 | https://faultdecode.com/ac/mitsubishi/#code-4-flashes |
ac | Mitsubishi Electric | 5 flashes | upper operation lamp | Inverter only (FAQ flash table) | Indoor control system: compressor stopped after 3 over-current or start-up failure protections within 1 minute of start-up | null | https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysi... | 2026-10-28 | https://faultdecode.com/ac/mitsubishi/#code-5-flashes |
ac | Mitsubishi Electric | 6 flashes | upper operation lamp | Inverter only (FAQ flash table) | Outdoor thermistor short or open circuit | null | https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysi... | 2026-10-28 | https://faultdecode.com/ac/mitsubishi/#code-6-flashes |
ac | Mitsubishi Electric | 7 flashes | upper operation lamp | Inverter only (FAQ flash table) | Outdoor control system: indoor or outdoor PCB failure | null | https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysi... | 2026-10-28 | https://faultdecode.com/ac/mitsubishi/#code-7-flashes |
ac | Mitsubishi Electric | 11 flashes | upper operation lamp | FAQ flash table | Indoor fan motor: no fan speed feedback signal for 12 seconds of indoor fan operation | null | https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysi... | 2026-10-28 | https://faultdecode.com/ac/mitsubishi/#code-11-flashes |
ac | Mitsubishi Electric | 14 flashes | upper operation lamp | FAQ flash table | Refrigerant circuit: unit pumped down for a long time, low refrigerant, short cycling, or outdoor fan motor locked | null | https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysi... | 2026-10-28 | https://faultdecode.com/ac/mitsubishi/#code-14-flashes |
ac | Mitsubishi Electric | 00 | remote CHECK display | Indoor unit (MSY-GR, MSY-JS remote check) | No error (normal) | null | https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysi... | 2026-10-28 | https://faultdecode.com/ac/mitsubishi/#code-00 |
ac | Mitsubishi Electric | E6/E7 | remote CHECK display | Indoor unit (MSY-GR, MSY-JS remote check) | Serial signal (abnormal point; read with the remote CHECK button) | null | https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysi... | 2026-10-28 | https://faultdecode.com/ac/mitsubishi/#code-e6-e7 |
ac | Mitsubishi Electric | Fb | remote CHECK display | Indoor unit (MSY-GR, MSY-JS remote check) | Indoor control system | null | https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysi... | 2026-10-28 | https://faultdecode.com/ac/mitsubishi/#code-fb |
ac | Mitsubishi Electric | P1 | remote CHECK display | Indoor unit (MSY-GR, MSY-JS remote check) | Room temperature thermistor | null | https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysi... | 2026-10-28 | https://faultdecode.com/ac/mitsubishi/#code-p1 |
ac | Mitsubishi Electric | P2/P9 | remote CHECK display | Indoor unit (MSY-GR, MSY-JS remote check) | Indoor coil thermistor | null | https://www.mitsubishielectricmalaysia.com/air-conditioner-frequently-asked-questions/ https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/06/JSSeries-MSY-JS18-24VF.pdf https://www.mitsubishielectricmalaysia.com/wp-content/uploads/2022/07/JRseries-MS-JR10131824VF.pdf https://www.mitsubishielectricmalaysi... | 2026-10-28 | https://faultdecode.com/ac/mitsubishi/#code-p2-p9 |