question stringlengths 54 152 | expected_answer stringlengths 1 39 | structured dict | chunk IDs listlengths 1 1 | candidate_response dict | candidate_score dict |
|---|---|---|---|---|---|
What is the sound power level of the geoTHERM perform VWS 400/3 S1? | ≤ 54 dB(A) | {"schema":{"answer_type":"object","fields":[{"name":"sound_power_level_dba","type":"number","descrip(...TRUNCATED) | [
"uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_802"
] | {"http_code":201,"response":{"response":"The answer is clearly found in the technical data. Here is (...TRUNCATED) | {"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly states the s(...TRUNCATED) |
What is the transferable power of the PHE S plate heat exchanger for system separation? | 120 kW | {"schema":{"answer_type":"object","fields":[{"name":"transferable_power_kw","type":"number","descrip(...TRUNCATED) | [
"uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_1083"
] | {"http_code":201,"response":{"response":"## PHE S Plate Heat Exchanger – Transferable Power 🔧\n(...TRUNCATED) | {"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly states the t(...TRUNCATED) |
"What is the maximum domestic hot water temperature achievable with the aroSTOR VWL B 80/5 using onl(...TRUNCATED) | 55 °C | {"schema":{"answer_type":"object","fields":[{"name":"max_dhw_temp_celsius","type":"number","descript(...TRUNCATED) | [
"uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_830"
] | {"http_code":201,"response":{"response":"## aroSTOR VWL B 80/5 — Maximum DHW Temperature (Heat Pum(...TRUNCATED) | {"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly states 55 °(...TRUNCATED) |
"What is the minimum installation room size required for the VWL 75/5 AS + VWL 77/5 IS with a coolan(...TRUNCATED) | 7.1 m³ | {"schema":{"answer_type":"object","fields":[{"name":"min_room_size_m3","type":"number","description"(...TRUNCATED) | [
"uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_509"
] | {"http_code":201,"response":{"response":"The Graph Tool is currently unavailable, but the value is c(...TRUNCATED) | {"accuracy":0,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly identifies t(...TRUNCATED) |
"How long does it take to heat up the aroSTOR VWL B 150/5 at an environmental air temperature of 7°(...TRUNCATED) | 9.37 h | {"schema":{"answer_type":"object","fields":[{"name":"heat_up_time_hours","type":"number","descriptio(...TRUNCATED) | [
"uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_831"
] | {"http_code":201,"response":{"response":"The answer is directly available from the technical data ta(...TRUNCATED) | {"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly states the h(...TRUNCATED) |
"What is the coefficient of performance for active water/water cooling of the flexoTHERM exclusive V(...TRUNCATED) | 5.60 | {"schema":{"answer_type":"object","fields":[{"name":"cop_cooling","type":"number","description":"Coe(...TRUNCATED) | [
"uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_159"
] | {"http_code":201,"response":{"response":"The Graph Tool is currently unavailable. However, the data (...TRUNCATED) | {"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly identifies t(...TRUNCATED) |
What noise reduction does the VWZ noise insulation for the 500 x 600 air duct provide? | Approx. 3–4 dB reduction in sound power | {"schema":{"answer_type":"object","fields":[{"name":"noise_reduction_min_db","type":"number","descri(...TRUNCATED) | [
"uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_1047"
] | {"http_code":201,"response":{"response":"## VWZ Noise Insulation for 500 × 600 Air Duct 🔇\n\nThe(...TRUNCATED) | {"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly states that (...TRUNCATED) |
How much additional refrigerant must be filled on-site for the geoTHERM perform VWS 780/3 S1? | 1.8 kg | {"schema":{"answer_type":"object","fields":[{"name":"additional_refrigerant_kg","type":"number","des(...TRUNCATED) | [
"uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_803"
] | {"http_code":201,"response":{"response":"## geoTHERM perform VWS 780/3 S1 — Additional Refrigerant(...TRUNCATED) | {"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly states 1.8 k(...TRUNCATED) |
What is the V40 value (usable hot water volume at 40°C) of the fluoSTOR VWH B 270/1? | 344 l | {"schema":{"answer_type":"object","fields":[{"name":"v40_liters","type":"integer","description":"V40(...TRUNCATED) | [
"uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_890"
] | {"http_code":201,"response":{"response":"The answer is clearly available from the technical data tab(...TRUNCATED) | {"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly states the V(...TRUNCATED) |
"What is the sound power level of the aroTHERM perform VWL 255/3 AS S4 outdoor unit in noise reducti(...TRUNCATED) | 57 dB(A) | {"schema":{"answer_type":"object","fields":[{"name":"sound_power_noise_reduction_dba","type":"number(...TRUNCATED) | [
"uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_772"
] | {"http_code":201,"response":{"response":"The Graph Tool is currently unavailable. However, the knowl(...TRUNCATED) | {"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly identifies t(...TRUNCATED) |
End of preview. Expand in Data Studio
No dataset card yet
- Downloads last month
- 10