Dataset Viewer
Auto-converted to Parquet Duplicate
question
stringlengths
54
152
expected_answer
stringlengths
1
39
structured
dict
chunk IDs
listlengths
1
1
candidate_response
dict
candidate_score
dict
What is the sound power level of the geoTHERM perform VWS 400/3 S1?
≤ 54 dB(A)
{"schema":{"answer_type":"object","fields":[{"name":"sound_power_level_dba","type":"number","descrip(...TRUNCATED)
[ "uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_802" ]
{"http_code":201,"response":{"response":"The answer is clearly found in the technical data. Here is (...TRUNCATED)
{"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly states the s(...TRUNCATED)
What is the transferable power of the PHE S plate heat exchanger for system separation?
120 kW
{"schema":{"answer_type":"object","fields":[{"name":"transferable_power_kw","type":"number","descrip(...TRUNCATED)
[ "uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_1083" ]
{"http_code":201,"response":{"response":"## PHE S Plate Heat Exchanger – Transferable Power 🔧\n(...TRUNCATED)
{"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly states the t(...TRUNCATED)
"What is the maximum domestic hot water temperature achievable with the aroSTOR VWL B 80/5 using onl(...TRUNCATED)
55 °C
{"schema":{"answer_type":"object","fields":[{"name":"max_dhw_temp_celsius","type":"number","descript(...TRUNCATED)
[ "uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_830" ]
{"http_code":201,"response":{"response":"## aroSTOR VWL B 80/5 — Maximum DHW Temperature (Heat Pum(...TRUNCATED)
{"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly states 55 °(...TRUNCATED)
"What is the minimum installation room size required for the VWL 75/5 AS + VWL 77/5 IS with a coolan(...TRUNCATED)
7.1 m³
{"schema":{"answer_type":"object","fields":[{"name":"min_room_size_m3","type":"number","description"(...TRUNCATED)
[ "uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_509" ]
{"http_code":201,"response":{"response":"The Graph Tool is currently unavailable, but the value is c(...TRUNCATED)
{"accuracy":0,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly identifies t(...TRUNCATED)
"How long does it take to heat up the aroSTOR VWL B 150/5 at an environmental air temperature of 7°(...TRUNCATED)
9.37 h
{"schema":{"answer_type":"object","fields":[{"name":"heat_up_time_hours","type":"number","descriptio(...TRUNCATED)
[ "uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_831" ]
{"http_code":201,"response":{"response":"The answer is directly available from the technical data ta(...TRUNCATED)
{"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly states the h(...TRUNCATED)
"What is the coefficient of performance for active water/water cooling of the flexoTHERM exclusive V(...TRUNCATED)
5.60
{"schema":{"answer_type":"object","fields":[{"name":"cop_cooling","type":"number","description":"Coe(...TRUNCATED)
[ "uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_159" ]
{"http_code":201,"response":{"response":"The Graph Tool is currently unavailable. However, the data (...TRUNCATED)
{"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly identifies t(...TRUNCATED)
What noise reduction does the VWZ noise insulation for the 500 x 600 air duct provide?
Approx. 3–4 dB reduction in sound power
{"schema":{"answer_type":"object","fields":[{"name":"noise_reduction_min_db","type":"number","descri(...TRUNCATED)
[ "uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_1047" ]
{"http_code":201,"response":{"response":"## VWZ Noise Insulation for 500 × 600 Air Duct 🔇\n\nThe(...TRUNCATED)
{"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly states that (...TRUNCATED)
How much additional refrigerant must be filled on-site for the geoTHERM perform VWS 780/3 S1?
1.8 kg
{"schema":{"answer_type":"object","fields":[{"name":"additional_refrigerant_kg","type":"number","des(...TRUNCATED)
[ "uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_803" ]
{"http_code":201,"response":{"response":"## geoTHERM perform VWS 780/3 S1 — Additional Refrigerant(...TRUNCATED)
{"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly states 1.8 k(...TRUNCATED)
What is the V40 value (usable hot water volume at 40°C) of the fluoSTOR VWH B 270/1?
344 l
{"schema":{"answer_type":"object","fields":[{"name":"v40_liters","type":"integer","description":"V40(...TRUNCATED)
[ "uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_890" ]
{"http_code":201,"response":{"response":"The answer is clearly available from the technical data tab(...TRUNCATED)
{"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly states the V(...TRUNCATED)
"What is the sound power level of the aroTHERM perform VWL 255/3 AS S4 outdoor unit in noise reducti(...TRUNCATED)
57 dB(A)
{"schema":{"answer_type":"object","fields":[{"name":"sound_power_noise_reduction_dba","type":"number(...TRUNCATED)
[ "uploads/vaillant_global_150825/Productinformation_Vaillant.pdf_772" ]
{"http_code":201,"response":{"response":"The Graph Tool is currently unavailable. However, the knowl(...TRUNCATED)
{"accuracy":1,"completeness":1,"relevance":1,"reasoning":"The proposed answer correctly identifies t(...TRUNCATED)
End of preview. Expand in Data Studio

No dataset card yet

Downloads last month
10