File size: 108,417 Bytes
5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c 77127fd 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c 77127fd 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c 77127fd 5d12f8c a035ca7 5d12f8c 77127fd 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c 77127fd 5d12f8c a035ca7 5d12f8c 77127fd 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c 77127fd 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c 77127fd 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c a035ca7 5d12f8c 77127fd 5d12f8c a035ca7 5d12f8c 77127fd 5d12f8c 77127fd 5d12f8c 77127fd 5d12f8c a035ca7 5d12f8c 77127fd 5d12f8c 77127fd 5d12f8c | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 | # Coverage
Every model the verifier serves, each stop its own description names, and whether a row of this dataset brackets it. A stop is **covered** when a row holds the last request that stands and the nearest one past it. It is **not reachable from the worked example** when no change of one number in the model's own worked example met it next to a request that stands. It is **not attempted** when a change of shape reaches it (a word, the length of a list, a load changed by a visible amount part way, a run continued from another), where there is no pair of numbers either side.
Stops named in a model's description were read from the address on the date the rows carry. The first seven models are the seven on https://zerotrustphysics.com.
| Model | Rows | Named stops covered | Not reachable | Not attempted | Outcome flips |
|---|---|---|---|---|---|
| `energy/reactor_spert3` | 15 | 6 of 18 | 11 | 1 | 4 |
| `aerospace/capsule_stardust` | 13 | 7 of 13 | 6 | 0 | 4 |
| `aerospace/los_jwst_fine_guide` | 57 | 6 of 19 | 12 | 1 | 0 |
| `energy/grid_gb` | 15 | 8 of 18 | 9 | 1 | 2 |
| `aerospace/satellite_lageos1` | 18 | 5 of 13 | 8 | 0 | 1 |
| `materials/tire_eve_r19_ice` | 29 | 8 of 15 | 7 | 0 | 4 |
| `energy/generator_mmrtg_f1` | 10 | 3 of 10 | 7 | 0 | 5 |
| `energy/accumulator_sbo450` | 19 | 6 of 19 | 13 | 0 | 0 |
| `energy/battery_sag` | 7 | 5 of 12 | 7 | 0 | 1 |
| `materials/cable_stretch` | 12 | 5 of 12 | 7 | 0 | 5 |
| `signal/cantilever_eth` | 7 | 4 of 10 | 6 | 0 | 0 |
| `aerospace/capsule_insight` | 15 | 5 of 14 | 9 | 0 | 0 |
| `energy/cell_18650pf` | 12 | 7 of 14 | 7 | 0 | 1 |
| `energy/cell_2170_m80` | 15 | 7 of 17 | 9 | 1 | 0 |
| `energy/cell_2170_model3` | 29 | 11 of 22 | 10 | 1 | 2 |
| `aerospace/crater_ryugu_sci` | 6 | 4 of 11 | 7 | 0 | 2 |
| `materials/creep_cmsx6` | 12 | 6 of 14 | 8 | 0 | 3 |
| `materials/fingerpad_p02_glass` | 14 | 6 of 14 | 7 | 1 | 3 |
| `energy/grid_node` | 22 | 5 of 13 | 8 | 0 | 2 |
| `materials/hydraulic_fluid` | 10 | 5 of 12 | 7 | 0 | 2 |
| `signal/link_gothenburg_10010` | 11 | 6 of 16 | 10 | 0 | 0 |
| `energy/reactor_spert3_ccore` | 24 | 7 of 21 | 13 | 1 | 11 |
| `energy/reactor_spert3_fuel` | 16 | 6 of 20 | 13 | 1 | 5 |
| `energy/reactor_triga_jsi` | 19 | 7 of 25 | 17 | 1 | 6 |
| `signal/resonance` | 10 | 5 of 13 | 8 | 0 | 0 |
| `aerospace/solar_system` | 166 | 3 of 18 | 15 | 0 | 0 |
| `energy/swing` | 12 | 5 of 11 | 6 | 0 | 2 |
| `signal/tesseract` | 10 | 3 of 11 | 8 | 0 | 0 |
| `energy/thermal` | 15 | 3 of 10 | 7 | 0 | 3 |
| `materials/ti64_lattice` | 38 | 6 of 13 | 7 | 0 | 0 |
| `energy/tokamak_jet_dte1` | 33 | 13 of 30 | 17 | 0 | 0 |
| `ablator_slab` | 46 | 12 of 29 | 10 | 7 | 0 |
| `argon_pair_gas` | 4 | 3 of 12 | 9 | 0 | 0 |
| `atom_dft` | 2 | 1 of 9 | 8 | 0 | 0 |
| `culture_trichoderma_ambr250` | 29 | 10 of 19 | 7 | 2 | 0 |
| `fusion_pb11_lhd` | 10 | 6 of 12 | 6 | 0 | 0 |
| `fusion_pb11_thermal` | 14 | 7 of 15 | 8 | 0 | 0 |
| `journal_bearing_sheffield` | 4 | 2 of 7 | 5 | 0 | 0 |
| `modulus_bam_s355` | 6 | 2 of 16 | 11 | 3 | 0 |
| `pipe_flow_superpipe` | 7 | 3 of 16 | 13 | 0 | 0 |
| `propeller_apc_10x7e` | 12 | 3 of 11 | 8 | 0 | 0 |
| `seawater_column` | 20 | 7 of 19 | 11 | 1 | 0 |
| `step_flow_armaly` | 3 | 2 of 9 | 7 | 0 | 0 |
| `tokamak_dt_beam_target` | 88 | 14 of 29 | 12 | 3 | 0 |
In all: 936 rows; 255 named stops covered, 401 not reachable from the worked example, 25 not attempted.
Left out of the rows on purpose: stops that belong to the form of a request and not to a model (a number that is not a finite normal 64-bit number, a count of steps below 1 or above 1,000,000, more than 10,000 recorded frames).
## `energy/reactor_spert3`
The SPERT III E-core test reactor, cold, from a step in reactivity to the first maximum of power.
15 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidCard` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `ReactivityOutsideCard` | covered | 2 | by `segments[0].load.reactivity_inserted_dollar` |
| `CoolantTemperatureOutsideCard` | covered | 2 | by `initial.coolant_temperature_k` |
| `PastFirstMaximum` | covered | 3 | declared end; by `dt_s`, `segments[0].load.reactivity_inserted_dollar`, `segments[0].steps` |
| `TimeBeyondCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `EnergyBeyondCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `PowerBeyondCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `ReactivityChangedDuringBurst` | covered | 2 | by `segments[1].load.reactivity_inserted_dollar` |
| `NegativeState` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `InconsistentState` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationNotOnCard` | not attempted | | reached by a change of shape: the worked run continued from itself with its start unchanged |
| flip of `first_past: power_mw above 100.0` | covered | 1 | an outcome flip inside the range |
| flip of `past_first_maximum` | covered | 3 | an outcome flip inside the range |
## `aerospace/capsule_stardust`
The Stardust sample return capsule on its entry of 15 January 2006, from entry interface down to the drogue-deployment condition the radar recorded, under 31030 m and under Mach 1.23 at once, past which a state is refused: no lift, no wind, a yearly standard atmosphere, and no load. One entry was compared with the flight, the locked entry from entry interface; off that path the card holds the limits each field states.
13 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidCapsule` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `AltitudeOutsideCard` | covered | 1 | by `initial.radius_m` |
| `MachOutsideCard` | covered | 1 | by `initial.radius_m` |
| `AirSpeedOutsideCard` | covered | 3 | by `initial.radial_speed_m_s`, `initial.transverse_speed_m_s` |
| `PastFlightDeployment` | covered | 1 | declared end; by `segments[0].steps` |
| `OffComparedCorridor` | covered | 1 | by `initial.radial_speed_m_s` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| flip of `drogue_mach_window` | covered | 2 | an outcome flip inside the range |
| flip of `first_past: heat_flux_w_m2 above 5000000.0` | covered | 1 | an outcome flip inside the range |
| flip of `first_past: load_g above 10.0` | covered | 1 | an outcome flip inside the range |
## `aerospace/los_jwst_fine_guide`
The line of sight of the James Webb Space Telescope in quiet fine guide, as its Fine Guidance Sensor reads it every 64 ms: a Kalman filter stepped through the flight centroids of one fine-guide file, with eighteen constants fitted to this observatory's own centroids of April 2022. On quiet frames of held-back visits it met its five marks. It was compared on quiet fine guide only: on engine 0.10.1 a centroid more than 5 mas from the lock point, or more than four stated standard deviations from where it was expected, was refused and ended the run, and a new run started no earlier than 30 s later; since 0.11 the model answers those frames with the same equations and flags them.
57 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidObservatory` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `LockOutsideCard` | not reachable from the worked example | | met only past another stop: `OffsetOutsideCard` comes first |
| `RecoveryNotElapsed` | covered | 1 | by `initial.quiet_before_start_s` |
| `InvalidCovariance` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `MeasuredNotZeroOrOne` | covered | 2 | by `segments[*].load.measured` |
| `UnmeasuredFrameCarriesNumbers` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `MeasurementGapOutsideCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `CountRateOutsideCard` | covered | 16 | by `segments[0].load.counts_per_s`, `segments[1].load.counts_per_s`, `segments[2].load.counts_per_s`, `segments[3].load.counts_per_s` and 4 more |
| `OffsetOutsideCard` | not reachable from the worked example | | met only past another stop: `PointingDisturbance`, `LockOutsideCard` comes first |
| `PointingDisturbance` | not reachable from the worked example | | met only past another stop: `OffsetOutsideCard`, `InnovationBeyondFourSigma` comes first |
| `InnovationBeyondFourSigma` | covered | 36 | by `initial.lock_x_arcsec`, `initial.lock_y_arcsec`, `segments[0].load.centroid_x_arcsec`, `segments[0].load.centroid_y_arcsec` and 14 more |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationNotOnCard` | not attempted | | reached by a change of shape: the worked run continued from itself with its start unchanged |
## `energy/grid_gb`
The Great Britain synchronous area, the 50 Hz transmission system of England, Scotland and Wales as one rotating mass, in the 60 seconds after an importing interconnector trips. It is the served model of that event at any date: on trips from mid-2018 to early 2025 it met its lines, and on the six compared trips since November 2025 its fall is 39 to 80 percent deeper than the measured fall.
15 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidCard` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `LossOutsideCard` | covered | 2 | by `segments[0].load.loss_mw` |
| `LossChangedDuringRun` | covered | 2 | by `segments[1].load.loss_mw` |
| `StartFrequencyOutsideCard` | covered | 2 | by `initial.frequency_hz` |
| `InertiaOutsideCard` | covered | 2 | by `initial.inertia_mw_s` |
| `DemandOutsideCard` | covered | 2 | by `initial.demand_mw` |
| `TimeBeyondCard` | covered | 1 | declared end; by `segments[0].steps` |
| `LowFrequencyDemandDisconnection` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `FrequencyBelowCompared` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `FrequencyAboveCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationNotOnCard` | not attempted | | reached by a change of shape: the worked run continued from itself with its start unchanged |
| flip of `first_past: frequency_hz below 49.7` | covered | 2 | an outcome flip inside the range |
## `aerospace/satellite_lageos1`
The laser-ranging satellite LAGEOS-1 in free flight, in a frame turning with the Earth: the Earth's field to degree and order 12, the Sun and the Moon, the solid tide, sunlight pressure and relativity, with no load.
18 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidSatellite` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `RadiusOutsideCard` | not reachable from the worked example | | met only past another stop: `OrbitOutsideCard` comes first |
| `OrbitOutsideCard` | covered | 12 | by `initial.position_m[0]`, `initial.position_m[1]`, `initial.position_m[2]`, `initial.velocity_m_s[0]` and 2 more |
| `EpochOutsideCard` | covered | 2 | by `initial.epoch_utc_s` |
| `HorizonOutsideCard` | covered | 1 | by `segments[0].steps` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationWithoutUpstream` | not reachable from the worked example | | met only past another stop: a stop with no name, `HorizonOutsideCard` comes first |
| flip of `first_past: position_m[2] above 0.0` | covered | 1 | an outcome flip inside the range |
## `materials/tire_eve_r19_ice`
One 235/55 R19 all-season tyre rolling on ice at a held slip on the Terramechanics Rig at Virginia Tech, at the rig's creep of 0.06 m/s: the longitudinal force and the work, from a friction ratio fitted to this tyre's own measurements.
29 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidTire` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `NormalLoadOutsideCard` | covered | 4 | by `segments[0].load.normal_load_n`, `segments[1].load.normal_load_n` |
| `InflationPressureOutsideCard` | covered | 4 | by `segments[0].load.inflation_pressure_pa`, `segments[1].load.inflation_pressure_pa` |
| `SlipOutsideCard` | covered | 4 | by `segments[0].load.slip_ratio` |
| `CarriageSpeedOutsideCard` | covered | 4 | by `segments[0].load.carriage_speed_m_s`, `segments[1].load.carriage_speed_m_s` |
| `TravelBeyondTrack` | covered | 2 | declared end; by `initial.distance_m` |
| `SlipNotSettled` | covered | 3 | by `initial.slip_held_s`, `segments[1].load.slip_ratio` |
| `HoldBeyondMeasured` | covered | 3 | by `dt_s`, `initial.slip_held_s`, `segments[0].steps` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | not reachable from the worked example | | met only past another stop: `HoldBeyondMeasured` comes first |
| flip of `first_past: longitudinal_force_n above 1200.0` | covered | 2 | an outcome flip inside the range |
| flip of `load_above_fitted` | covered | 2 | an outcome flip inside the range |
## `energy/generator_mmrtg_f1`
One radioisotope generator, flight unit F1, on the Curiosity rover: its daily-average electrical output from landing to mission day 4,087, with no load; on the 1,279 held-back days, 2,809 to 4,087, it was inside its line of 0.010 of 115.4 W by root mean square (0.008129, about 0.94 W) and outside it in its mean over the final 365 days (+0.010094, about 1.16 W high), so it failed its comparison by the rule fixed beforehand and is served with that stated. Its worst day read 2.60 W high.
10 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidGenerator` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `MissionTimeOutsideCard` | covered | 3 | declared end; by `initial.mission_time_s`, `segments[0].steps` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `ConverterAccountBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| flip of `first_past: electrical_power_w below 100.0` | covered | 2 | an outcome flip inside the range |
| flip of `first_past: electrical_power_w below 110.0` | covered | 1 | an outcome flip inside the range |
| flip of `past_fitting_span` | covered | 2 | an outcome flip inside the range |
## `energy/accumulator_sbo450`
The nitrogen charge of one HYDAC SBO450-0.6 diaphragm accumulator on the test rig at TU Darmstadt, as a piston pushes oil in and draws it out: gas pressure, temperature and an energy ledger. The ratio of piston area to vessel volume and the thermal time constant are fitted to this accumulator's own runs at 40 bar precharge and 60 bar. Compared with 285 held-back runs at 40, 80 and 120 bar and at half the charge, 0.01 to 20 Hz: the comparison failed, two of six lines met, and a second scoring confirmed it. Amended after that with every run opened, which is not a new test: on engine 0.10.1 the card refused by name outside the range in which it held: a precharge of 20 bar at gas pressures of 37 to 43 or 55 to 67 bar, or of 40 bar at 57 to 64 or 75 to 86 bar, the bands in which each charge was measured, a wall at 293.4 to 293.7 K, gas at 285.9 to 301.8 K and a piston at most 0.7 m/s, as in the measured runs, and heat at most 0.065 of the work over the whole motion, which in the measured sines is 0.2 Hz and faster; since 0.11 a step outside that range keeps going with the same equations and is flagged, up to the vessel's rated 330 bar, and heat above 0.065 of the work is still refused. Run after the fact on 0.10.1 it answered 196 of those 285 runs and refused 89; on the 196 the swing of gas pressure per piston travel is within 0.49 percent in the median, 1.37 in the worst record and 4.05 at most.
19 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidAccumulator` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `GasMassOutsideCard` | covered | 4 | by `initial.gas_mass_kg` |
| `WallTemperatureOutsideCard` | covered | 2 | by `initial.wall_temperature_k` |
| `PistonSpeedOutsideCard` | not reachable from the worked example | | met only past another stop: `PistonTravelAboveStep` comes first |
| `PistonTravelAboveStep` | not reachable from the worked example | | met only past another stop: `PressureOutsideChargeBands`, `PistonSpeedOutsideCard`, `DtAboveCeiling` comes first |
| `GasTemperatureOutsideCard` | covered | 2 | by `initial.gas_temperature_k` |
| `PressureOutsideCard` | covered | 1 | by `initial.gas_pressure_pa` |
| `PressureOutsideChargeBands` | covered | 9 | by `dt_s`, `initial.gas_pressure_pa`, `segments[0].load.piston_speed_m_s`, `segments[0].steps` and 1 more |
| `NegativeMovedSum` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `OilSideEmpty` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `HeatShareAboveCard` | not reachable from the worked example | | met only past another stop: `ContinuationWithoutUpstream` comes first |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | not reachable from the worked example | | met only past another stop: `PistonTravelAboveStep` comes first |
| `ContinuationWithoutUpstream` | not reachable from the worked example | | met only past another stop: a stop with no name, `HeatShareAboveCard` comes first |
## `energy/battery_sag`
A 12S lithium-ion pack under a terminal current.
7 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidPack` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `CurrentAboveNyquist` | covered | 2 | by `segments[0].load.current_a`, `segments[1].load.current_a` |
| `UndervoltageCutoff` | covered | 1 | by `initial.soc` |
| `OvervoltageCutoff` | not reachable from the worked example | | met only past another stop: `CurrentAboveNyquist`, a stop with no name comes first |
| `StateOfChargeOutsideCard` | covered | 1 | by `initial.soc` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| flip of `sag_warning` | covered | 1 | an outcome flip inside the range |
## `materials/cable_stretch`
A Dyneema tendon under a commanded force.
12 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidCable` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `ForceAboveNyquist` | covered | 2 | by `segments[0].load.force_n`, `segments[1].load.force_n` |
| `TensileFailure` | covered | 2 | by `initial.elongation_m`, `initial.velocity_m_s` |
| `Slack` | not reachable from the worked example | | met only past another stop: a stop with no name, `ForceAboveNyquist` comes first |
| `SubnormalState` | covered | 1 | by `initial.elongation_m` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| flip of `control_limited` | covered | 2 | an outcome flip inside the range |
| flip of `tracking_degraded` | covered | 3 | an outcome flip inside the range |
## `signal/cantilever_eth`
One aluminium strip clamped at one end at ETH Zürich, ringing down freely in room air in its first bending mode: the deflection at the laser-1 station, 268 mm from the clamp, with no load.
7 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidBeam` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `DeflectionAboveCard` | covered | 4 | by `initial.deflection_m`, `initial.velocity_m_s` |
| `DeflectionBelowCard` | covered | 1 | by `segments[0].steps` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
## `aerospace/capsule_insight`
The InSight entry capsule on its entry at Mars of 26 November 2018, from the top of the atmosphere to just past the flight's parachute deployment, down to 5700 m or Mach 1.46: no wind, the air of orbiter soundings set on the lander's barometer, and the capsule's lift as the load. Only runs from the locked entry state were compared with the flight; on engine 0.10.1 only states on the corridor they flew were answered, and since 0.11 other starts keep going with the same equations, down to the landing site, and are flagged. It does not forecast an entry whose lift is not known.
15 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidCapsule` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `LiftOutsideCard` | covered | 3 | by `segments[0].load.lift_over_drag`, `segments[1].load.lift_over_drag` |
| `AltitudeOutsideCard` | not reachable from the worked example | | met only past another stop: `PastComparedFlight`, `OffComparedCorridor` comes first |
| `MachOutsideCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `AirSpeedOutsideCard` | not reachable from the worked example | | met only past another stop: `OffComparedCorridor` comes first |
| `PastComparedFlight` | covered | 3 | declared end; by `segments[0].load.lift_over_drag`, `segments[0].steps`, `segments[1].load.lift_over_drag` |
| `OffComparedCorridor` | covered | 7 | by `initial.radial_speed_m_s`, `initial.radius_m`, `initial.transverse_speed_m_s`, `segments[1].load.lift_over_drag` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
## `energy/cell_18650pf`
One Panasonic NCR18650PF cell in a held 1C discharge from full charge, with no temperature and no memory of the load before (a real cell's voltage relaxes for minutes after a change of load); on engine 0.10.1 it took only the 1C currents compared with measurement, 2.89817 to 2.90065 A, and since 0.11 a step at any other current keeps going with the same equations and is flagged.
12 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidCell` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `CurrentNotCompared` | covered | 3 | by `initial.held_current_a`, `segments[0].load.current_a`, `segments[1].load.current_a` |
| `CurrentChangedDuringDischarge` | covered | 3 | by `initial.held_current_a`, `segments[0].load.current_a`, `segments[1].load.current_a` |
| `StartNotAtFullCharge` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `StateOfChargeOutsideCard` | covered | 1 | by `initial.soc` |
| `UndervoltageCutoff` | covered | 1 | by `segments[0].steps` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationWithoutUpstream` | covered | 1 | by `initial.soc` |
| flip of `sag_warning` | covered | 1 | an outcome flip inside the range |
## `energy/cell_2170_m80`
One Tesla Model 3 2170 lithium-ion cell, cell m80 alone, from 0 to 40 degC, under a terminal current and a measured case temperature.
15 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidCell` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `StepNotOneSecond` | covered | 2 | by `dt_s` |
| `BlockNotRecognized` | covered | 2 | by `initial.block_chamber_c` |
| `BlockShownWrong` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `CaseTemperatureOutsideCard` | not reachable from the worked example | | met only past another stop: `CaseTemperatureOutsideBlock` comes first |
| `CaseTemperatureOutsideBlock` | covered | 4 | by `segments[0].load.case_temperature_c`, `segments[1].load.case_temperature_c` |
| `CurrentOutsideCard` | not reachable from the worked example | | met only past another stop: `CurrentOutsideBlock` comes first |
| `CurrentOutsideBlock` | covered | 2 | by `segments[0].load.current_a`, `segments[1].load.current_a` |
| `ChargeOutsideTables` | covered | 2 | by `initial.charge_removed_ah`, `segments[0].load.current_a` |
| `LowerVoltageLimit` | covered | 2 | by `initial.charge_removed_ah`, `segments[0].steps` |
| `UpperVoltageLimit` | covered | 1 | by `segments[1].load.current_a` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `ContinuationNotOnCard` | not attempted | | reached by a change of shape: the worked run continued from itself with its start unchanged |
## `energy/cell_2170_model3`
One Tesla Model 3 2170 lithium-ion cell, any of the three cells m80, m1000 and m448-N of its dataset, as a physical model with memory, from -10 to 40 degC, under a terminal current and a measured case temperature.
29 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidCell` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `CellNotRecognized` | covered | 6 | by `initial.cell_number` |
| `CapacityOutsideCard` | not reachable from the worked example | | met only past another stop: `CapacityOutsideCardAtTemperature` comes first |
| `CaseTemperatureOutsideCard` | not reachable from the worked example | | met only past another stop: `CaseTemperatureSpanAboveCard`, `CapacityOutsideCardAtTemperature` comes first |
| `CurrentOutsideCard` | not reachable from the worked example | | met only past another stop: `OvervoltageLimit`, `SustainedCurrentOutsideCard` comes first |
| `CapacityOutsideCardAtTemperature` | covered | 5 | by `initial.capacity_ah`, `segments[1].load.case_temperature_c` |
| `CaseTemperatureChangeAboveCard` | covered | 1 | by `segments[1].load.case_temperature_c` |
| `CaseTemperatureSpanAboveCard` | covered | 2 | by `initial.case_temperature_least_c`, `initial.case_temperature_most_c` |
| `SustainedCurrentOutsideCard` | covered | 2 | by `segments[0].load.current_a`, `segments[1].load.current_a` |
| `StateOfChargeOutsideCard` | covered | 1 | by `initial.state_of_charge` |
| `SurfaceOutsideCurve` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `UndervoltageLimit` | covered | 2 | by `initial.state_of_charge`, `segments[0].steps` |
| `OvervoltageLimit` | covered | 2 | by `segments[0].load.current_a`, `segments[1].load.current_a` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationWithoutUpstream` | covered | 4 | by `initial.case_temperature_least_c`, `initial.case_temperature_most_c`, `segments[0].load.case_temperature_c` |
| `ContinuationNotOnCard` | not attempted | | reached by a change of shape: the worked run continued from itself with its start unchanged |
| flip of `sustained_above_1c` | covered | 2 | an outcome flip inside the range |
## `aerospace/crater_ryugu_sci`
The crater made on asteroid Ryugu by the 2 kg copper impactor of Hayabusa2 on 5 April 2019: its radius growing from 1.75 m until it stops, by the law of crater size for dry sand held by gravity alone, fitted in the laboratory on Earth and not to Ryugu, with no load; its predicted radius is 18 percent above the measured crater, a miss of its own line, and its clock is not compared with Ryugu.
6 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidCrater` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `RadiusBelowCard` | covered | 1 | by `initial.radius_m` |
| `RadiusAboveFinal` | covered | 1 | declared end; by `initial.radius_m` |
| `WallMovingInward` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| flip of `stopped` | covered | 2 | an outcome flip inside the range |
## `materials/creep_cmsx6`
One cast of the single-crystal nickel alloy CMSX-6, loaded along [001] at 980 degrees Celsius, creeping in tension under a held load: the percentage creep extension of a round test piece 6 mm in diameter against the time since the full load, from 0.1 percent to 5 percent at 170 to 230 MPa and from 0.1 to 0.2 percent at 140 to under 170 MPa. Six constants fitted to six creep tests of this cast; the time to a level met its three lines on six held-back tests. Below 0.1 percent, and past 0.2 percent under 170 MPa, the law misses the measured curves; there the card refused on engine 0.10.1, and since 0.11 it answers with those misses stated and flags every step.
12 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidCard` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `StressOutsideCard` | covered | 2 | by `segments[0].load.stress_mpa` |
| `StressNotHeld` | covered | 2 | by `segments[1].load.stress_mpa` |
| `CreepExtensionBelowCard` | covered | 1 | by `initial.creep_extension_percent` |
| `CreepExtensionOutsideCard` | not reachable from the worked example | | met only past another stop: `CreepExtensionBeyondCard` comes first |
| `CreepExtensionBeyondCard` | covered | 2 | by `initial.creep_extension_percent`, `segments[0].steps` |
| `StepTooSmallToResolve` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| flip of `creep_rate_rising` | covered | 3 | an outcome flip inside the range |
## `materials/fingerpad_p02_glass`
One human finger pad pressed on flat glass at 2 N (1.93 to 2.07 N) and twisted about the normal at 5 to 50 degrees a second until it slips, the right index finger of participant P02 of the torsion experiment at UCLouvain: the torque, the stuck fraction of the contact, the work and the heat, from eight constants fitted to this finger's own trials. Compared on 2026-10-09 with its held-back trials at 1 N, 10 N and 100 degrees a second and missed: the slip torque was off by +9, +29 and -13 percent against a mark of 5.6 percent; on engine 0.10.1 those conditions and every other load were refused by name, and since 0.11 it answers at every force and rate above zero with those misses stated and flags every step where nothing was measured. What was left on 0.10.1 was the one block of trials the fit took its level from: there this finger slipped at 10 to 11 N mm and the card gives that to about 8 percent, on trials it was fitted to, which is not a test. Another block of the same finger differs by 13 to 15 percent, another finger by about a fifth.
14 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidFingerPad` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `NormalForceOutsideCard` | covered | 2 | by `segments[0].load.normal_force_n` |
| `TwistRateOutsideCard` | covered | 1 | by `segments[0].load.twist_rate_deg_s` |
| `LoadChangedDuringTwist` | covered | 4 | by `segments[1].load.normal_force_n`, `segments[1].load.twist_rate_deg_s` |
| `TwistNotStartedFromZero` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `TwistBeyondMeasured` | covered | 2 | by `segments[0].load.twist_rate_deg_s`, `segments[0].steps` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationNotOnCard` | not attempted | | reached by a change of shape: the worked run continued from itself with its start unchanged |
| flip of `full_slip` | covered | 3 | an outcome flip inside the range |
## `energy/grid_node`
A copper fuse link between an upstream voltage and a load current.
22 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `NegativeTemperature` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `TemperatureOutsideCard` | covered | 6 | by `initial.temperature_k`, `segments[0].load.ambient_k`, `segments[1].load.ambient_k` |
| `InvalidNode` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `CopperMelt` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `CurrentOutsideCard` | covered | 6 | by `initial.current_a`, `segments[0].load.load_current_a`, `segments[1].load.load_current_a` |
| `VoltageOutsideCard` | covered | 6 | by `initial.voltage_v`, `segments[0].load.upstream_voltage_v`, `segments[1].load.upstream_voltage_v` |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| flip of `surge` | covered | 2 | an outcome flip inside the range |
## `materials/hydraulic_fluid`
A mineral-oil column under a commanded flow.
10 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidChamber` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `FlowAboveNyquist` | not reachable from the worked example | | met only past another stop: `FlowAboveAcoustic` comes first |
| `FlowAboveAcoustic` | covered | 2 | by `segments[0].load.flow_m3_s`, `segments[1].load.flow_m3_s` |
| `Cavitation` | covered | 3 | by `initial.pressure_pa`, `segments[0].load.flow_m3_s`, `segments[1].load.flow_m3_s` |
| `PressureAboveCard` | covered | 1 | by `initial.pressure_pa` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| flip of `column_limited` | covered | 1 | an outcome flip inside the range |
| flip of `column_soft` | covered | 1 | an outcome flip inside the range |
## `signal/link_gothenburg_10010`
One 32.445 GHz microwave link across 1.26 km of Gothenburg in rain, OpenMRG link 10010 sublink 587: its path loss from the rain rate at the gauge beside it. The rain term is Recommendation ITU-R P.838-3 with nothing fitted; the three constants of the water on the antennas are fitted to this link's own readings of June and July 2015.
11 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidLink` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `RainRateOutsideCard` | covered | 3 | by `initial.gauge_minute_rain_mm_h`, `segments[0].load.rain_rate_mm_h`, `segments[1].load.rain_rate_mm_h` |
| `RainRateBelowGaugeCount` | covered | 3 | by `initial.gauge_minute_rain_mm_h`, `segments[0].load.rain_rate_mm_h`, `segments[1].load.rain_rate_mm_h` |
| `RainNotHeldForGaugeMinute` | not reachable from the worked example | | met only past another stop: a stop with no name, `GaugeMinuteOutsideCard` comes first |
| `GaugeMinuteOutsideCard` | not reachable from the worked example | | met only past another stop: a stop with no name, `RainNotHeldForGaugeMinute` comes first |
| `DryPathLossOutsideCard` | covered | 2 | by `initial.dry_path_loss_db` |
| `AntennaWaterOutsideCard` | covered | 1 | by `initial.antenna_water_db` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `AntennaAccountBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationWithoutUpstream` | not reachable from the worked example | | no change of one number from the worked example reached it |
## `energy/reactor_spert3_ccore`
The SPERT III C-core test reactor (stainless-steel-clad, highly enriched plates) in step transients from room temperature at 0 to 2500 psig with no flow, or 200 to 20,000 gpm at 230 psig only, through the first maximum of power to the first maximum of the plate surface temperature at the hot spot; two constants are fitted, and by the rule fixed beforehand the comparison with its 39 held-back transients failed on all three lines.
24 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidCard` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `InitialTemperatureOutsideCard` | covered | 2 | by `initial.initial_temperature_k` |
| `PressureOutsideCard` | covered | 1 | by `initial.system_pressure_psig` |
| `FlowOutsideCard` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `ReactivityOutsideCard` | covered | 2 | by `segments[0].load.reactivity_inserted_dollar` |
| `PastPlateTemperatureMaximum` | covered | 4 | declared end; by `dt_s`, `initial.initial_temperature_k`, `segments[0].load.reactivity_inserted_dollar`, `segments[0].steps` |
| `TimeBeyondCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `NegativeState` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `EnergyBeyondCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `PowerBeyondCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `ReactivityChangedDuringRun` | covered | 2 | by `segments[1].load.reactivity_inserted_dollar` |
| `FlowChangedDuringRun` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `InconsistentState` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationNotOnCard` | not attempted | | reached by a change of shape: the worked run continued from itself with its start unchanged |
| flip of `past_plate_maximum` | covered | 4 | an outcome flip inside the range |
| flip of `past_power_peak` | covered | 3 | an outcome flip inside the range |
| flip of `prompt_supercritical` | covered | 4 | an outcome flip inside the range |
## `energy/reactor_spert3_fuel`
The SPERT III E-core test reactor in low-initial-power bursts at three inlet temperatures, from the start of the transient rod's motion to the first maximum of power, with the fuel temperature and the water temperature as state; four constants are fitted, and by the rule fixed beforehand the comparison with its 30 held-back tests failed.
16 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidCard` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `InletTemperatureOutsideCard` | covered | 2 | by `initial.inlet_temperature_k` |
| `ReactivityOutsideCard` | covered | 2 | by `segments[0].load.reactivity_inserted_dollar` |
| `FlowOutsideCard` | not reachable from the worked example | | met only past another stop: `InletTemperatureOutsideCard`, a stop with no name comes first |
| `PastFirstMaximum` | covered | 3 | declared end; by `dt_s`, `segments[0].load.reactivity_inserted_dollar`, `segments[0].steps` |
| `TimeBeyondCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `NegativeState` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `EnergyBeyondCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `PowerBeyondCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `ReactivityChangedDuringBurst` | covered | 2 | by `segments[1].load.reactivity_inserted_dollar` |
| `FlowChangedDuringBurst` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `InconsistentState` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationNotOnCard` | not attempted | | reached by a change of shape: the worked run continued from itself with its start unchanged |
| flip of `past_first_maximum` | covered | 3 | an outcome flip inside the range |
| flip of `rod_moving` | covered | 2 | an outcome flip inside the range |
## `energy/reactor_triga_jsi`
The TRIGA Mark II reactor of the Jozef Stefan Institute, Ljubljana, with its 56-element core of standard fuel, in pulse mode from 2.0 to 3.0 printed dollars on the rod-worth tables of cores 215, 217 and 231: power, energy released and core-average fuel temperature from the fire signal through the pulse to the scram. Ten constants are fitted to 36 pulses of this reactor, in a form added after the twelve fixed beforehand had failed; by the rule fixed beforehand the comparison with the 20 rows held back failed, four of six lines missed, with peak power 23 and 44 percent low on a day the card was not fitted to; the fuel temperature was compared only through one thermocouple of one element. After that scoring the lower limit was raised from 1.4 to 2.0 dollars, where the held-back rows had read up to 29 percent low: below 2.0 dollars the card refused by name on engine 0.10.1, and since 0.11 it computes the same equations there, with nothing compared, and flags every step.
19 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidCard` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `StartTemperatureOutsideCard` | covered | 2 | by `initial.start_temperature_k` |
| `RodTableOutsideCard` | covered | 4 | by `initial.rod_table_core` |
| `ReactivityOutsideCard` | covered | 3 | by `segments[0].load.reactivity_inserted_dollar`, `segments[1].load.reactivity_inserted_dollar` |
| `ScramValueOutsideCard` | not reachable from the worked example | | met only past another stop: a stop with no name, `ScramBeforeRodStopped`, `ScramBeforeCompared` comes first |
| `ReactivityChangedDuringRun` | covered | 1 | by `segments[1].load.reactivity_inserted_dollar` |
| `ScramBeforeRodStopped` | not reachable from the worked example | | met only past another stop: `ScramValueOutsideCard` comes first |
| `ScramBeforeCompared` | not reachable from the worked example | | met only past another stop: `ScramValueOutsideCard` comes first |
| `RodsHeldBeyondCompared` | covered | 1 | by `segments[0].steps` |
| `RodsRaisedAfterScram` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `NegativeEnergy` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `ImpossiblePeak` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `StateOutsideCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `TimeBeyondCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `EnergyBeyondCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `PowerBeyondCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `FuelTemperatureBeyondCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationNotOnCard` | not attempted | | reached by a change of shape: the worked run continued from itself with its start unchanged |
| flip of `prompt_supercritical` | covered | 4 | an outcome flip inside the range |
| flip of `rod_moving` | covered | 2 | an outcome flip inside the range |
## `signal/resonance`
A 10 Hz mount oscillator under an imposed acceleration.
10 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidOscillator` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `ForceAboveNyquist` | covered | 2 | by `segments[1].load.accel_m_s2` |
| `AmplitudeAboveCard` | covered | 2 | by `segments[0].load.accel_m_s2` |
| `StartTimeOutsideCard` | not reachable from the worked example | | met only past another stop: a stop with no name, `ContinuationWithoutUpstream` comes first |
| `LedgerNotOfThisState` | not reachable from the worked example | | met only past another stop: `ContinuationWithoutUpstream`, `AmplitudeAboveCard`, a stop with no name comes first |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationWithoutUpstream` | covered | 4 | by `initial.displacement_m`, `initial.velocity_m_s` |
## `aerospace/solar_system`
The Solar System as thirteen point masses in free motion: the Sun, Mercury, Venus, the Earth, the Moon, the barycentres of the Mars, Jupiter, Saturn, Uranus and Neptune systems, and Ceres, Pallas and Vesta, under Newton's and the relativistic forces between every pair and the Earth's oblateness on the Moon, with the constants of JPL's DE440 and nothing fitted. The caller supplies every position and velocity. The comparison started from JPL's own state of 1999 and was made with range measurements that state was fitted to.
166 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidSystem` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `DistanceOutsideCard` | not reachable from the worked example | | met only past another stop: `OrbitOutsideCard`, `DistanceOutsideComparedRun` comes first |
| `OrbitOutsideCard` | not reachable from the worked example | | met only past another stop: `DistanceOutsideCard`, `SpontaneousGeneration`, `FrameOutsideCard` comes first |
| `DistanceOutsideComparedRun` | not reachable from the worked example | | met only past another stop: `OrbitOutsideCard`, `OriginOutsideCard`, `SpontaneousGeneration` comes first |
| `BodiesCoincide` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `BodiesTooClose` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `FrameOutsideCard` | not reachable from the worked example | | met only past another stop: `OrbitOutsideCard`, `FirstLawBreach`, `SpontaneousGeneration` comes first |
| `OriginOutsideCard` | not reachable from the worked example | | met only past another stop: `DistanceOutsideComparedRun`, `OrbitOutsideCard`, `SpontaneousGeneration` comes first |
| `AxesOutsideCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `SpontaneousGeneration` | not reachable from the worked example | | met only past another stop: `ContinuationWithoutUpstream`, `OrbitOutsideCard`, `AngularMomentumBreach` comes first |
| `FirstLawBreach` | not reachable from the worked example | | met only past another stop: `ContinuationWithoutUpstream`, `AngularMomentumBreach`, `OrbitOutsideCard` comes first |
| `AngularMomentumBreach` | not reachable from the worked example | | met only past another stop: `ContinuationWithoutUpstream`, `SpontaneousGeneration`, `FirstLawBreach` comes first |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationWithoutUpstream` | covered | 164 | by `initial.angular_momentum_anchor[0]`, `initial.angular_momentum_anchor[1]`, `initial.angular_momentum_anchor[2]`, `initial.ceres_position_m[0]` and 78 more |
## `energy/swing`
A synchronous 60 Hz machine under mechanical power.
12 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidMachine` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `LossOfSynchronism` | covered | 2 | by `initial.delta_rad` |
| `SpeedDeviationOutsideCard` | covered | 2 | by `initial.delta_omega_rad_s` |
| `DispatchOutsideCard` | covered | 4 | by `segments[0].load.p_mech_pu`, `segments[1].load.p_mech_pu` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| flip of `pll_slipped` | covered | 2 | an outcome flip inside the range |
## `signal/tesseract`
A drive-mode Duffing resonator under acceleration, an external rate, and sensed velocity.
10 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidResonator` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `ForceAboveNyquist` | not reachable from the worked example | | met only past another stop: `AmplitudeOutsideCard` comes first |
| `AmplitudeOutsideCard` | covered | 8 | by `initial.displacement_m`, `initial.velocity_m_s`, `segments[0].load.accel_m_s2`, `segments[1].load.accel_m_s2` |
| `SpontaneousGeneration` | not reachable from the worked example | | met only past another stop: `ContinuationWithoutUpstream` comes first |
| `FirstLawBreach` | not reachable from the worked example | | met only past another stop: `ContinuationWithoutUpstream` comes first |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationWithoutUpstream` | not reachable from the worked example | | met only past another stop: a stop with no name, `FirstLawBreach`, `SpontaneousGeneration` comes first |
## `energy/thermal`
An avionics cold plate under heater power and a bath temperature.
15 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `NegativeTemperature` | not reachable from the worked example | | met only past another stop: `TemperatureOutsideCard` comes first |
| `TemperatureOutsideCard` | covered | 10 | by `initial.temperature_k`, `segments[0].load.ambient_k`, `segments[0].load.heat_power_w`, `segments[1].load.ambient_k` and 1 more |
| `InvalidNode` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| flip of `derated` | covered | 3 | an outcome flip inside the range |
## `materials/ti64_lattice`
An annealed Ti-6Al-4V lattice column under nodal force, torque, and temperature.
38 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `TemperatureOutsideCard` | covered | 2 | by `segments[0].load.temperature_k`, `segments[1].load.temperature_k` |
| `InvalidCell` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `YieldReached` | covered | 14 | by `segments[0].load.force_n[0]`, `segments[0].load.force_n[1]`, `segments[0].load.force_n[2]`, `segments[0].load.temperature_k` and 4 more |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `StartNotWritten` | covered | 6 | by `initial.start_force_n[0]`, `initial.start_force_n[1]`, `initial.start_force_n[2]` |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ForceAboveNyquist` | not reachable from the worked example | | met only past another stop: `YieldReached` comes first |
| `ContinuationWithoutUpstream` | covered | 14 | by `initial.position_m[0]`, `initial.position_m[1]`, `initial.position_m[2]`, `initial.start_temperature_k` and 3 more |
## `energy/tokamak_jet_dte1`
The plasma of the JET tokamak in an ELMy H-mode pulse of 1996 to 1997, deuterium or deuterium-tritium: its thermal energy, its fast-ion energy and its D-T fusion power under the heating power, inside the envelope of the nine JET pulses of its regime it was compared with, 1.65 to 3.84 MA, 1.80 to 4.04 T, up to 24.3 MW of heating, the first 5.475 s of the heated window and a tritium fraction of 0 to 0.034 or 0.451 to 0.504; outside it the card refused by name on engine 0.10.1, and since 0.11 it computes the same equations there, with nothing compared, and flags every step. Compared on 2026-10-09 with two held-back JET pulses, and by the rule fixed beforehand the comparison failed: on 42982 the fusion energy released was 0.743 of the measured, under the 0.75 mark.
33 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonFiniteState` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NonPositiveDt` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `InvalidCard` | not reachable from the worked example | | names the model's own constants, which no request sets |
| `HeatingPowerOutsideCard` | covered | 3 | by `segments[0].load.heating_power_w`, `segments[1].load.heating_power_w` |
| `OhmicPowerOutsideCard` | covered | 4 | by `segments[0].load.ohmic_power_w`, `segments[1].load.ohmic_power_w` |
| `PlasmaCurrentOutsideCard` | covered | 2 | by `segments[0].load.plasma_current_a`, `segments[1].load.plasma_current_a` |
| `ToroidalFieldOutsideCard` | covered | 2 | by `segments[0].load.toroidal_field_t`, `segments[1].load.toroidal_field_t` |
| `FuelMixOutsideCard` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `FuelMixOutsideComparison` | covered | 6 | by `segments[0].load.tritium_fraction`, `segments[1].load.tritium_fraction` |
| `DensityBelowCard` | not reachable from the worked example | | met only past another stop: a stop with no name, `TemperatureOutsideComparison` comes first |
| `DensityAboveComparison` | covered | 2 | by `segments[0].load.line_density_per_m3`, `segments[1].load.line_density_per_m3` |
| `DensityAboveGreenwald` | not reachable from the worked example | | met only past another stop: `PlasmaCurrentOutsideCard`, `GreenwaldFractionAboveComparison` comes first |
| `GreenwaldFractionAboveComparison` | not reachable from the worked example | | met only past another stop: `DensityAboveGreenwald`, `SafetyFactorOutsideComparison` comes first |
| `SafetyFactorBelowLimit` | not reachable from the worked example | | met only past another stop: `ToroidalFieldOutsideCard`, `SafetyFactorOutsideComparison` comes first |
| `SafetyFactorOutsideComparison` | covered | 4 | by `segments[0].load.plasma_current_a`, `segments[0].load.toroidal_field_t`, `segments[1].load.plasma_current_a`, `segments[1].load.toroidal_field_t` |
| `EnergyOutsideCard` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `TemperatureBelowReactivityFit` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `TemperatureAboveReactivityFit` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `BetaAboveTroyon` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `EnergyOutsideComparison` | covered | 3 | by `initial.fast_ion_energy_j`, `segments[0].load.heating_power_w` |
| `TemperatureOutsideComparison` | covered | 3 | by `initial.thermal_energy_j`, `segments[0].load.line_density_per_m3`, `segments[1].load.line_density_per_m3` |
| `BetaOutsideComparison` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `ConfinementTimeOutsideComparison` | covered | 1 | by `initial.thermal_energy_j` |
| `TimeBeyondCard` | covered | 1 | by `segments[0].steps` |
| `SpontaneousGeneration` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FirstLawBreach` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DtBelowFloor` | covered | 1 | by `dt_s` |
| `DtAboveCeiling` | covered | 1 | by `dt_s` |
| `ContinuationWithoutUpstream` | not reachable from the worked example | | met only past another stop: a stop with no name, `TimeBeyondCard` comes first |
## `ablator_slab`
A flat slab of charring heat-shield material heated on one face, held at a temperature or in a gas stream: wear, face temperature, depth of charring, and the heat and mass accounts, for a PICA model built from the open record or the test material TACOT.
46 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `UnknownMaterial` | not attempted | | reached by a change of shape: the word material changed to one not listed |
| `ThicknessOutOfRange` | covered | 1 | by `parameters.thickness_m` |
| `StartTemperatureOutOfRange` | covered | 2 | by `parameters.start_temperature_k` |
| `ThermocoupleOutsideSlab` | covered | 7 | by `parameters.thermocouple_depths_m[0]`, `parameters.thermocouple_depths_m[1]`, `parameters.thermocouple_depths_m[2]`, `parameters.thermocouple_depths_m[3]` and 3 more |
| `UnknownFace` | not attempted | | reached by a change of shape: the word face changed to one not listed |
| `HeldTemperatureOutOfRange` | covered | 2 | by `parameters.held_temperature_k` |
| `HoldDurationOutOfRange` | covered | 2 | by `parameters.hold_duration_s` |
| `ContinueAfterOutOfRange` | covered | 1 | by `parameters.continue_after_s` |
| `UnknownStreamGas` | not attempted | | reached by a change of shape: the word stream_gas changed to one not listed |
| `StreamOxygenOutOfRange` | not reachable from the worked example | | met only past another stop: `QuestionNotCompared` comes first |
| `StreamArgonOutOfRange` | not reachable from the worked example | | met only past another stop: a stop with no name, `QuestionNotCompared` comes first |
| `HistoryDurationOutOfRange` | covered | 1 | by `parameters.history_time_s[2]` |
| `StreamPressureOutOfRange` | not reachable from the worked example | | met only past another stop: `QuestionNotCompared` comes first |
| `HeatTransferCoefficientOutOfRange` | not reachable from the worked example | | met only past another stop: a stop with no name, `QuestionNotCompared` comes first |
| `FlowEnthalpyOutOfRange` | not reachable from the worked example | | met only past another stop: a stop with no name, `QuestionNotCompared` comes first |
| `RadiativeHeatingOutOfRange` | not reachable from the worked example | | met only past another stop: a stop with no name, `QuestionNotCompared` comes first |
| `SurroundingsTemperatureOutOfRange` | not reachable from the worked example | | met only past another stop: `SurroundingsNotCompared` comes first |
| `ThicknessNotCompared` | covered | 2 | by `parameters.thickness_m` |
| `QuestionNotCompared` | covered | 23 | by `parameters.history_flow_enthalpy_j_per_kg[0]`, `parameters.history_flow_enthalpy_j_per_kg[1]`, `parameters.history_flow_enthalpy_j_per_kg[2]`, `parameters.history_heat_transfer_coefficient_kg_per_m2_s[0]` and 9 more |
| `HistoryTimesOutOfOrder` | not reachable from the worked example | | met only past another stop: a stop with no name, `HistoryRowsTooClose`, `HistoryDurationOutOfRange` comes first |
| `StartTemperatureNotCompared` | covered | 2 | by `parameters.start_temperature_k` |
| `SurfaceChemistryNotConverged` | not reachable from the worked example | | met only past another stop: a stop with no name, `QuestionNotCompared` comes first |
| `HistoryRowsTooClose` | covered | 1 | by `parameters.history_time_s[1]` |
| `FlowEnthalpyBelowWall` | not reachable from the worked example | | met only past another stop: a stop with no name, `QuestionNotCompared` comes first |
| `SurroundingsNotCompared` | covered | 2 | by `parameters.surroundings_temperature_k` |
| `HeldFaceNotCompared` | not attempted | | reached by a change of shape: the word material changed to another listed |
| `TooManyThermocouples` | not attempted | | reached by a change of shape: the list thermocouple_depths_m 400 long |
| `StreamNotAirForThisMaterial` | not attempted | | reached by a change of shape: the word material changed to another listed |
| `FaceNotWearingNotCompared` | not attempted | | reached by a change of shape: the flag face_wears turned |
## `argon_pair_gas`
Argon gas at low density from one Lennard-Jones pair potential whose two constants are fitted to the measured speed of sound in argon: second virial coefficient, speed of sound and viscosity at zero density. On engine 0.10.1 each property was answered where it was compared: the speed of sound from 250 K to 349.868 K at 30.5 kPa to 467.2 kPa, the viscosity from 291.09 K to 681.96 K at zero pressure; elsewhere the solver refused by name. Since 0.11 it keeps going past that with the same equations, from 250 K to 6000 K, where argon begins to ionize, at 0 to 500 kPa.
4 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `TemperatureOutOfRange` | covered | 1 | by `parameters.temperature_k` |
| `PressureOutOfRange` | not reachable from the worked example | | met only past another stop: a stop with no name, `PressureNotCompared` comes first |
| `PressureNotCompared` | covered | 2 | by `parameters.pressure_kpa` |
| `SoundSpeedNotCompared` | covered | 1 | by `parameters.temperature_k` |
| `ViscosityNotCompared` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `NonFiniteValue` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `VirialNotSettled` | not reachable from the worked example | | every solve tried settled |
| `VirialFormsDisagree` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `TurningPointNotOutermost` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `DeflectionNotSettled` | not reachable from the worked example | | every solve tried settled |
| `CrossSectionNotSettled` | not reachable from the worked example | | every solve tried settled |
| `CollisionIntegralNotSettled` | not reachable from the worked example | | every solve tried settled |
## `atom_dft`
Spin-unpolarized, non-relativistic local-density ground state of one spherical neutral atom, atomic number 1 through 18: total energy, its four parts, and each orbital eigenvalue. It reproduces the NIST spin-unpolarized LDA tables and is not the measured energy of the atom.
2 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `AtomicNumberOutOfRange` | covered | 2 | by `parameters.atomic_number` |
| `ShellsDoNotHoldElectrons` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `ElectronCountBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `NegativeDensity` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `NonFiniteValue` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `OrbitalNotBound` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `EigenvalueStepOutOfRange` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `NotConverged` | not reachable from the worked example | | every solve tried settled |
| `VirialBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
## `culture_trichoderma_ambr250`
One fed-batch culture of the fungus Trichoderma sp. VTT D-221704 in an ambr 250 vessel at pH 4.0 and 35 °C, turning D-galacturonate into mucic acid: biomass, glucose, galacturonate, mucic acid, carbon dioxide made and oxygen taken up at the end of every segment of the caller's feeding record, with carbon and electrons closed; six constants are fitted to this organism's own measurements, at a feed of 29.4 to 34.7 g/L glucose; on four held-back cultures fed 10 and 50 g/L it met three of its six lines and missed three (galacturonate, mucic acid and carbon dioxide), a second scoring confirmed it, and it is not validated against measurement. On engine 0.10.1 it refused by name a feed outside the fitted 29.375 to 34.676 g/L glucose and a record longer than 215 h, so the four held-back questions were refused, and, from 0.7.0, a starting biomass, glucose or galacturonate, a feed schedule, water, sample or broth volume outside the fitted cultures' own. Since 0.11 it answers any start, feed and feed schedule from zero, the four held-back questions among them, held only by its own limits.
29 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteValue` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `BiomassOutOfRange` | covered | 2 | by `parameters.biomass_g_per_l` |
| `GlucoseOutOfRange` | covered | 2 | by `parameters.glucose_g_per_l` |
| `GalacturonateOutOfRange` | covered | 2 | by `parameters.galacturonate_g_per_l` |
| `FeedGlucoseOutOfRange` | covered | 2 | by `parameters.feed_glucose_g_per_l` |
| `FeedGalacturonateOutOfRange` | covered | 2 | by `parameters.feed_galacturonate_g_per_l` |
| `SegmentCountOutOfRange` | not attempted | | reached by a change of shape: the list segment_end_h empty |
| `SegmentsDoNotMatch` | not attempted | | reached by a change of shape: the list segment_end_h one shorter |
| `SegmentLengthOutOfRange` | not reachable from the worked example | | met only past another stop: a stop with no name, `FeedScheduleOutOfRange`, `FeedRateOutOfRange` comes first |
| `RunTooLong` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `FeedRateOutOfRange` | covered | 2 | by `parameters.feed_ml[2]`, `parameters.segment_end_h[2]` |
| `FeedScheduleOutOfRange` | covered | 8 | by `parameters.feed_ml[1]`, `parameters.feed_ml[2]`, `parameters.segment_end_h[0]`, `parameters.segment_end_h[1]` and 1 more |
| `WaterRateOutOfRange` | covered | 5 | by `parameters.water_ml[0]`, `parameters.water_ml[1]`, `parameters.water_ml[2]` |
| `SampleOutOfRange` | covered | 3 | by `parameters.sample_ml[0]`, `parameters.sample_ml[1]`, `parameters.sample_ml[2]` |
| `VolumeOutOfRange` | covered | 1 | by `parameters.water_ml[1]` |
| `ConcentrationBelowZero` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `NotSettled` | not reachable from the worked example | | every solve tried settled |
| `CarbonLedgerBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `ElectronLedgerBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
## `fusion_pb11_lhd`
Proton-boron-11 fusion in the boron-seeded hydrogen plasma of the Large Helical Device under one hydrogen neutral beam of 45 keV or of 127.45 to 160.25 keV: alpha particles per second, fusion power, the share of beam protons that fuse, and the alpha emissivity profile. No constant is fitted. On engine 0.10.1 it answered only inside the envelope of the inputs compared with measured alpha count rates, each beam family inside its own, and refused outside it by name; since 0.11 it keeps going with the same equations, for a beam above the 10 keV stopping energy to 190 keV, and stops only at a physical limit, and says why. Compared with one published calculation and, in shape only, with measured alpha count rates: it missed three of its four pass lines. It is not validated against measurement.
10 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `BeamEnergyOutOfRange` | covered | 2 | by `parameters.beam_energy_kev` |
| `BeamPowerOutOfRange` | covered | 2 | by `parameters.beam_power_w` |
| `ElectronDensityOutOfRange` | covered | 2 | by `parameters.electron_density_per_m3` |
| `ElectronTemperatureOutOfRange` | covered | 2 | by `parameters.electron_temperature_kev` |
| `BoronDensityOutOfRange` | not reachable from the worked example | | met only past another stop: a stop with no name, `BoronShareOutOfRange` comes first |
| `BoronBelowOneNucleus` | covered | 1 | by `parameters.boron_density_per_m3` |
| `BoronShareOutOfRange` | covered | 1 | by `parameters.boron_density_per_m3` |
| `BoronChargeExceedsElectrons` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `NonFiniteValue` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NotSettled` | not reachable from the worked example | | every solve tried settled |
| `ProtonLedgerBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `EnergyLedgerBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
## `fusion_pb11_thermal`
Energy balance of a uniform thermal proton-boron-11 plasma, ion temperature 200 to 450 keV: the electron temperature at which the electrons balance, fusion, bremsstrahlung, synchrotron and exchange power, and the ignition margin. No constant is fitted. No such plasma has been made: it is checked against published calculations only, on engine 0.10.1 it answered only inside the inputs of that comparison, and since 0.11 at ion temperatures of 1 to 1000 keV, where the balance's own forms hold, and of its eight gated pass lines seven were met and one was missed.
14 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `IonTemperatureOutOfRange` | covered | 2 | by `parameters.ion_temperature_kev` |
| `ElectronDensityOutOfRange` | covered | 2 | by `parameters.electron_density_per_m3` |
| `BoronFractionOutOfRange` | covered | 2 | by `parameters.boron_fraction` |
| `AshFractionOutOfRange` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `MagneticFieldOutOfRange` | covered | 2 | by `parameters.magnetic_field_t` |
| `MinorRadiusOutOfRange` | covered | 2 | by `parameters.minor_radius_m` |
| `WallReflectivityOutOfRange` | covered | 2 | by `parameters.wall_reflectivity` |
| `ConfinementTimeOutOfRange` | covered | 2 | by `parameters.energy_confinement_time_s` |
| `NonFiniteValue` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `ChargeNotNeutral` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `PressureExceedsField` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `ElectronTemperatureOutOfRange` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `AlphaSharesBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `NotSettled` | not reachable from the worked example | | every solve tried settled |
| `EnergyBalanceBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
## `journal_bearing_sheffield`
Oil film of the University of Sheffield journal bearing test platform at 65 °C, load 2 to 20 kN, speed 100 to 800 rpm: Sommerfeld number, eccentricity ratio and minimum film thickness. One constant, a viscosity multiplier, is fitted to measurements of this bearing.
4 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `LoadOutOfRange` | covered | 2 | by `parameters.load_n` |
| `SpeedOutOfRange` | covered | 2 | by `parameters.speed_rpm` |
| `NonFiniteValue` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `EccentricityRatioOutOfRange` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `FilmNotSettled` | not reachable from the worked example | | every solve tried settled |
| `FlowBalanceBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `LoadNotCarried` | not reachable from the worked example | | no change of one number from the worked example reached it |
## `modulus_bam_s355`
Young's modulus and shear modulus of one of four test bars, each about 100 mm long, cut from one sheet of S355J2+N steel at BAM Berlin, worked back from the bar's measured resonant frequencies, with the edgewise frequency they predict: a property of those bars, not the strength or the load of a steel structure; the comparison with the independent tensile measurement missed its line, and no independent measurement confirms the returned moduli.
6 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `RepeatedMode` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `FrequencyOutOfRange` | covered | 4 | by `parameters.frequencies_hz[0]`, `parameters.frequencies_hz[1]`, `parameters.frequencies_hz[2]` |
| `YoungsModulusNotIdentifiable` | not attempted | | reached by a change of shape: the list frequencies_hz empty |
| `ShearModulusNotIdentifiable` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `OutsideSearchRange` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `FrequencyEquationNotBracketed` | not reachable from the worked example | | every solve tried settled |
| `NonFiniteValue` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `EnergyBalanceBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `FreeEndBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `NotConverged` | not reachable from the worked example | | every solve tried settled |
| `RoundTripBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `PoissonRatioOutOfRange` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `ModesInconsistent` | covered | 2 | by `parameters.frequencies_hz[0]`, `parameters.frequencies_hz[2]` |
| `PredictedEdgewiseOutOfRange` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `UnknownBar` | not attempted | | reached by a change of shape: the word bar changed to one not listed |
| `TooManyFrequencies` | not attempted | | reached by a change of shape: the list frequencies_hz one longer |
## `pipe_flow_superpipe`
Fully developed, smooth-wall, turbulent air flow in the Princeton Superpipe (129.36 mm bore), a mixing length with van Driest damping with nothing fitted (kappa 0.41, A+ 26): Darcy friction factor, centreline-to-bulk velocity ratio and the mean velocity profile, bulk Reynolds number 31,577 to 35,724,000 on engine 0.10.1 (since 0.11, 4000 to 1e10 and bulk Mach number up to 0.3), laminar, transitional and rough-wall flow refused by name; compared once with held-back Superpipe measurements of A. J. Smits' group: the friction line met (rms 1.38 percent, worst 2.69, against Prandtl-Karman's 2.17 rms) and the profile line met (1.59 percent), the centreline line missed at one of 21 profiles (2.99 percent low against 2 percent, the NSTAP profile at 81,330), so by the rule fixed beforehand the comparison failed; the friction factor falls below the measured one as the Reynolds number rises, 2.7 percent low at 35.7 million.
7 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `InputNotFinite` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `LaminarFlow` | not reachable from the worked example | | met only past another stop: `TransitionalFlow` comes first |
| `TransitionalFlow` | not reachable from the worked example | | met only past another stop: `LaminarFlow`, `ReynoldsOutOfRange` comes first |
| `ReynoldsOutOfRange` | not reachable from the worked example | | met only past another stop: `ReynoldsPerPascalOutOfRange`, `TransitionalFlow` comes first |
| `PressureOutOfRange` | not reachable from the worked example | | met only past another stop: `ReynoldsPerPascalOutOfRange` comes first |
| `TemperatureOutOfRange` | covered | 2 | by `parameters.temperature_k` |
| `ReynoldsPerPascalOutOfRange` | covered | 4 | by `parameters.bulk_reynolds_number`, `parameters.static_pressure_pa` |
| `RoughnessNegative` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `RoughWall` | covered | 1 | by `parameters.wall_roughness_rms_um` |
| `NonFiniteValue` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `SingularSystem` | not reachable from the worked example | | every solve tried settled |
| `ImbalanceGrew` | not reachable from the worked example | | every solve tried settled |
| `NotSettled` | not reachable from the worked example | | every solve tried settled |
| `FluxBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `MomentumLedgerBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `VelocityNotMonotone` | not reachable from the worked example | | no change of one number from the worked example reached it |
## `propeller_apc_10x7e`
Thrust and shaft power of the APC Thin Electric 10x7 propeller at one rotational speed, airspeed and air density, by blade-element momentum theory on its measured blade geometry, with two blade-section constants fitted to this propeller's own measured thrust and power; on the measurements held back from the fit it missed both of its lines, by up to 10.2 percent of full scale at speeds never fitted and 11.8 at rest.
12 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteInput` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `RotationalSpeedOutOfRange` | covered | 4 | by `parameters.rotational_speed_rev_per_min` |
| `AirDensityOutOfRange` | covered | 4 | by `parameters.air_density_kg_m3` |
| `AirspeedNegative` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `AdvanceRatioOutOfRange` | covered | 4 | by `parameters.airspeed_m_s` |
| `ReynoldsNumberOutOfRange` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `NonFiniteValue` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `NoBalance` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `NotSettled` | not reachable from the worked example | | every solve tried settled |
| `MomentumBalanceBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `DiscBalanceBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
## `seawater_column`
Depth, density and sound speed at every level of one measured seawater cast (pressure, temperature, salinity), from the TEOS-10 Gibbs function and the weight of the water above, and the depth an echo sounder reads over it; no constant is fitted.
20 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `NonFiniteValue` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `LatitudeOutOfRange` | not reachable from the worked example | | met only past another stop: `LatitudeOutsideCompared` comes first |
| `LevelCountOutOfRange` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `LevelsDoNotMatch` | not attempted | | reached by a change of shape: the list sea_pressure_dbar one shorter |
| `PressureOutOfRange` | not reachable from the worked example | | met only past another stop: a stop with no name, `LevelGapTooWide`, `FirstLevelTooDeep` comes first |
| `FirstLevelTooDeep` | covered | 1 | by `parameters.sea_pressure_dbar[0]` |
| `PressureNotRising` | covered | 1 | by `parameters.sea_pressure_dbar[12]` |
| `LevelGapTooWide` | covered | 3 | by `parameters.sea_pressure_dbar[12]`, `parameters.sea_pressure_dbar[6]` |
| `SalinityOutOfRange` | not reachable from the worked example | | met only past another stop: a stop with no name, `SalinityOutsideCompared` comes first |
| `TemperatureOutOfRange` | not reachable from the worked example | | met only past another stop: `TemperatureBelowFreezing`, `TemperatureOutsideCompared` comes first |
| `TemperatureBelowFreezing` | not reachable from the worked example | | met only past another stop: `TemperatureOutOfRange`, `TemperatureOutsideCompared` comes first |
| `HeightAboveBottomOutOfRange` | not reachable from the worked example | | met only past another stop: a stop with no name, `HeightAboveBottomOutsideCompared` comes first |
| `LatitudeOutsideCompared` | covered | 2 | by `parameters.latitude_deg` |
| `HeightAboveBottomOutsideCompared` | covered | 1 | by `parameters.height_above_bottom_m` |
| `DeeperThanCompared` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `SalinityOutsideCompared` | covered | 6 | by `parameters.practical_salinity[0]`, `parameters.practical_salinity[12]`, `parameters.practical_salinity[6]` |
| `TemperatureOutsideCompared` | covered | 6 | by `parameters.temperature_c[0]`, `parameters.temperature_c[12]`, `parameters.temperature_c[6]` |
| `ColumnNotSettled` | not reachable from the worked example | | every solve tried settled |
| `HydrostaticBalanceBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
## `step_flow_armaly`
Steady laminar air flow over the backward-facing step of the rig of Armaly and others (1983; step 4.9 mm, channel 5.2 mm opening to 10.1 mm), two-dimensional Navier-Stokes with nothing fitted: reattachment length and the velocity profile at one station, Reynolds number 100 to 389; compared with measured velocity profiles at 100 and at 389 only, second-hand and digitised, all three lines met at 389 and confirmed by a second scoring, and at 100 also first-hand from Armaly's Figure 15 out to 30.31 step heights; stations out to 30 step heights at 100, out to 13.57 above 100; the reattachment length at 100 is 14 percent below the sentence of NASA Technical Memorandum 106248 that quotes the measurement, a miss of that sentence, and 6 percent below Armaly's own plot as read first-hand afterwards, inside the mark; at 389 it is 6 to 7 percent below that plot.
3 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `ReynoldsOutOfRange` | covered | 2 | by `parameters.reynolds_number` |
| `StationOutOfRange` | covered | 1 | by `parameters.station_x_over_s` |
| `StationNotCompared` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `NonFiniteValue` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `SingularSystem` | not reachable from the worked example | | every solve tried settled |
| `ImbalanceGrew` | not reachable from the worked example | | every solve tried settled |
| `NotSettled` | not reachable from the worked example | | every solve tried settled |
| `OutletNotDeveloped` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `FlowPatternNotRecognised` | not reachable from the worked example | | no change of one number from the worked example reached it |
## `tokamak_dt_beam_target`
The deuterium-tritium fusion rate of one time slice of a JET or TFTR pulse in steady state, from its analysed profiles (temperatures, densities, fuel mix in up to 128 radial shells) and its neutral beams: thermal, beam-target from classical slowing-down with the Bosch-Hale cross-section, and beam-beam reactions, the fusion power and the neutron rate. No constant is fitted. Its held-back comparison failed: on the 34 slices of every TFTR tritium pulse of the profile database, another machine, the median of solver over database fusion power was 1.02, but 30 of the 34 lay inside 0.75 to 1.25 where nine in ten were asked (second scoring V-42: the same numbers). The reference is TRANSP's calculation on the same profiles and beam heating the solver is given, so agreement shows the solver's slowing-down arithmetic matches TRANSP's on TRANSP's own plasma and nothing about the neutron counters; against four measured values the solver is +7, +21, -11 and about +8 percent. After that failure limits were written in, on data by then spent and so tested blind by nothing, and are enforced by name. Since engine 0.7.0 the fast ions the solver finds are counted in each shell's charge balance and held from both sides at the extremes the slices compared and answered reach (no more than 12 percent over or 21.5 percent under the electrons), and on engine 0.10.1 the ranges of the physics were the span of those slices; since 0.11 it answers ion temperatures of 0.2 to 100 keV and beams to 1000 keV. The band is wide, and that is a finding: on TFTR the solver's own fast ions are 1.1 to 3.1 times the database's in the shell of largest excess, and the questions carry no thermal hydrogen, which TRANSP holds at 4 to 22 percent of the electrons at the edge. Of the 34 TFTR slices, 23 are answered on 0.7.0 as on 0.6.0, with the same bits: median 1.088, 21 of 23 inside 0.75 to 1.25 (1.015 and 23 of 23 with pulse 73268 against five times its database value, an alpha power). On JET the same 53 slices are answered, median 0.934, all inside the band.
88 rows.
| Stop | Status | Rows | Note |
|---|---|---|---|
| `ShellCountOutOfRange` | not attempted | | reached by a change of shape: the list shell_volume_m3 empty |
| `ProfileLengthsDiffer` | not attempted | | reached by a change of shape: the list shell_volume_m3 one shorter |
| `BeamComponentCountOutOfRange` | not attempted | | reached by a change of shape: the list beam_mass_number one shorter |
| `ShellVolumeOutOfRange` | covered | 4 | by `parameters.shell_volume_m3[0]`, `parameters.shell_volume_m3[1]`, `parameters.shell_volume_m3[2]`, `parameters.shell_volume_m3[3]` |
| `ElectronTemperatureOutOfRange` | covered | 1 | by `parameters.electron_temperature_kev[0]` |
| `IonTemperatureOutOfRange` | covered | 4 | by `parameters.ion_temperature_kev[0]`, `parameters.ion_temperature_kev[1]`, `parameters.ion_temperature_kev[2]`, `parameters.ion_temperature_kev[3]` |
| `TemperatureRatioOutOfRange` | covered | 8 | by `parameters.electron_temperature_kev[0]`, `parameters.electron_temperature_kev[1]`, `parameters.electron_temperature_kev[2]`, `parameters.electron_temperature_kev[3]` and 4 more |
| `ElectronDensityOutOfRange` | not reachable from the worked example | | met only past another stop: `ThermalChargeExceedsElectrons`, `IonChargeBelowElectrons` comes first |
| `IonDensityNegative` | not reachable from the worked example | | met only past another stop: a stop with no name comes first |
| `TritiumShareOutOfRange` | not reachable from the worked example | | met only past another stop: a stop with no name, `BeamChangeTooRecent`, `ThermalChargeExceedsElectrons` comes first |
| `ImpurityChargeOutOfRange` | covered | 1 | by `parameters.impurity_charge` |
| `ImpurityMassOutOfRange` | covered | 1 | by `parameters.impurity_mass_u` |
| `ThermalChargeExceedsElectrons` | covered | 12 | by `parameters.deuterium_density_per_m3[1]`, `parameters.deuterium_density_per_m3[2]`, `parameters.deuterium_density_per_m3[3]`, `parameters.electron_density_per_m3[1]` and 8 more |
| `BeamPowerOutOfRange` | not reachable from the worked example | | met only past another stop: a stop with no name, `BeamBeamShareTooLarge` comes first |
| `BeamSpeciesUnknown` | covered | 8 | by `parameters.beam_mass_number[0]`, `parameters.beam_mass_number[1]` |
| `BeamEnergyOutOfRange` | covered | 3 | by `parameters.beam_energy_kev[0]`, `parameters.beam_energy_kev[1]` |
| `BeamPowerShareOutOfRange` | covered | 4 | by `parameters.beam_power_share[0]`, `parameters.beam_power_share[1]` |
| `TimeSinceBeamChangeOutOfRange` | covered | 1 | by `parameters.time_since_beam_change_s` |
| `NonFiniteValue` | not reachable from the worked example | | a number that is not finite cannot be written in a request |
| `SlowingRateNotPositive` | not reachable from the worked example | | no change of one number from the worked example reached it |
| `NotSettled` | not reachable from the worked example | | every solve tried settled |
| `ParticleLedgerBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `EnergyLedgerBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `PowerLedgerBroken` | not reachable from the worked example | | a conservation account; it held in every run tried |
| `BeamBeamShareTooLarge` | not reachable from the worked example | | met only past another stop: `FastIonShareTooLarge`, `ShellVolumeOutOfRange`, `BeamPowerOutOfRange` comes first |
| `FastIonShareTooLarge` | not reachable from the worked example | | met only past another stop: `BeamBeamShareTooLarge`, `IonChargeExceedsElectrons`, `BeamChangeTooRecent` comes first |
| `BeamChangeTooRecent` | covered | 27 | by `parameters.beam_energy_kev[0]`, `parameters.beam_power_w[0]`, `parameters.beam_power_w[1]`, `parameters.beam_power_w[2]` and 21 more |
| `IonChargeExceedsElectrons` | covered | 10 | by `parameters.beam_power_w[2]`, `parameters.beam_power_w[3]`, `parameters.deuterium_density_per_m3[0]`, `parameters.electron_density_per_m3[0]` and 6 more |
| `IonChargeBelowElectrons` | covered | 4 | by `parameters.electron_density_per_m3[0]`, `parameters.electron_density_per_m3[1]`, `parameters.electron_density_per_m3[2]`, `parameters.electron_density_per_m3[3]` |
|