You need to agree to share your Hugging Face information to access this model

This repository is publicly accessible, but you have to accept the conditions to access its files and content.

These weights are derived from participant ECG recordings held under data-access agreements. Access is granted per project. State your institution and the approved use.

Log in or Sign Up to review the conditions and access this model content.

DeepECG-SSL ancestry -- five-fold ensemble

Predicts P(non-European genetic ancestry) from a 12-lead ECG. One logit through a sigmoid: p(European) = 1 - score. Five disjoint cross-validation folds, averaged.

Work in progress and unpublished. Quantitative performance, validation results and the cohorts involved are deliberately not described here; they are reported in the accompanying manuscript once it is published. Request access if you need to evaluate the model before then.

Layout

raw/fold_{1..5}/bs_128/checkpoint_best.pt   the five fine-tuned heads
reference/                                  frozen tables the pipeline compares against
MODEL_PROVENANCE.txt                        md5 of every checkpoint, and what produced it
CHECKSUMS.txt                               md5 + sha256 of every file here

The backbone is not in this repository. It is base_ssl.pt in the public, pinned heartwise/wcr_77_classes snapshot -- verified byte-identical (sha256 39985e904bfcc4e3fa58f3e631d84598c7228bfa821a3279109dc2e05f54383c) to the backbone these folds were fine-tuned from. Repinning that repository means re-checking that hash: a different backbone does not fail, it silently changes every score.

Use

pip install -r requirements.ancestry.txt          # DeepECG_Docker, branch DeepECG-Ancestry
export MODELS_ROOT=/path/to/this/snapshot
export REFERENCE_DIR=/path/to/this/snapshot/reference
export SSL_CKPT=/path/to/base_ssl.pt              # or let the manifest fetch it
python -m ancestry weights                        # confirms what resolved from where

Input is 12-lead, 2500 samples at 250 Hz, millivolts, lead-major. The loader refuses microvolts and raw ADC counts, because wrong units do not raise -- they give meaningless scores.

Limits

  • The label is binary European / non-European from genome-inferred ancestry. It is not self-declared race and must not be used as one.
  • Calibration depends on cohort prevalence. Recalibrate before any thresholded use.
  • Accuracy is not uniform across non-European groups.
  • Site effects can dominate in cohorts recorded on different hardware.
  • Not a clinical device. No outcome, diagnosis or treatment decision should rest on it.
Downloads last month

-

Downloads are not tracked for this model. How to track
Inference Providers NEW