new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Jun 4

Synthetic Data as Validation

This study leverages synthetic data as a validation set to reduce overfitting and ease the selection of the best model in AI development. While synthetic data have been used for augmenting the training set, we find that synthetic data can also significantly diversify the validation set, offering marked advantages in domains like healthcare, where data are typically limited, sensitive, and from out-domain sources (i.e., hospitals). In this study, we illustrate the effectiveness of synthetic data for early cancer detection in computed tomography (CT) volumes, where synthetic tumors are generated and superimposed onto healthy organs, thereby creating an extensive dataset for rigorous validation. Using synthetic data as validation can improve AI robustness in both in-domain and out-domain test sets. Furthermore, we establish a new continual learning framework that continuously trains AI models on a stream of out-domain data with synthetic tumors. The AI model trained and validated in dynamically expanding synthetic data can consistently outperform models trained and validated exclusively on real-world data. Specifically, the DSC score for liver tumor segmentation improves from 26.7% (95% CI: 22.6%-30.9%) to 34.5% (30.8%-38.2%) when evaluated on an in-domain dataset and from 31.1% (26.0%-36.2%) to 35.4% (32.1%-38.7%) on an out-domain dataset. Importantly, the performance gain is particularly significant in identifying very tiny liver tumors (radius < 5mm) in CT volumes, with Sensitivity improving from 33.1% to 55.4% on an in-domain dataset and 33.9% to 52.3% on an out-domain dataset, justifying the efficacy in early detection of cancer. The application of synthetic data, from both training and validation perspectives, underlines a promising avenue to enhance AI robustness when dealing with data from varying domains.

  • 3 authors
·
Oct 23, 2023

MRSegmentator: Robust Multi-Modality Segmentation of 40 Classes in MRI and CT Sequences

Purpose: To introduce a deep learning model capable of multi-organ segmentation in MRI scans, offering a solution to the current limitations in MRI analysis due to challenges in resolution, standardized intensity values, and variability in sequences. Materials and Methods: he model was trained on 1,200 manually annotated MRI scans from the UK Biobank, 221 in-house MRI scans and 1228 CT scans, leveraging cross-modality transfer learning from CT segmentation models. A human-in-the-loop annotation workflow was employed to efficiently create high-quality segmentations. The model's performance was evaluated on NAKO and the AMOS22 dataset containing 600 and 60 MRI examinations. Dice Similarity Coefficient (DSC) and Hausdorff Distance (HD) was used to assess segmentation accuracy. The model will be open sourced. Results: The model showcased high accuracy in segmenting well-defined organs, achieving Dice Similarity Coefficient (DSC) scores of 0.97 for the right and left lungs, and 0.95 for the heart. It also demonstrated robustness in organs like the liver (DSC: 0.96) and kidneys (DSC: 0.95 left, 0.95 right), which present more variability. However, segmentation of smaller and complex structures such as the portal and splenic veins (DSC: 0.54) and adrenal glands (DSC: 0.65 left, 0.61 right) revealed the need for further model optimization. Conclusion: The proposed model is a robust, tool for accurate segmentation of 40 anatomical structures in MRI and CT images. By leveraging cross-modality learning and interactive annotation, the model achieves strong performance and generalizability across diverse datasets, making it a valuable resource for researchers and clinicians. It is open source and can be downloaded from https://github.com/hhaentze/MRSegmentator.

  • 11 authors
·
May 10, 2024

Multi-modal Evidential Fusion Network for Trusted PET/CT Tumor Segmentation

Accurate segmentation of tumors in PET/CT images is important in computer-aided diagnosis and treatment of cancer. The key issue of such a segmentation problem lies in the effective integration of complementary information from PET and CT images. However, the quality of PET and CT images varies widely in clinical settings, which leads to uncertainty in the modality information extracted by networks. To take the uncertainty into account in multi-modal information fusion, this paper proposes a novel Multi-modal Evidential Fusion Network (MEFN) comprising a Cross-Modal Feature Learning (CFL) module and a Multi-modal Trusted Fusion (MTF) module. The CFL module reduces the domain gap upon modality conversion and highlights common tumor features, thereby alleviating the needs of the segmentation module to handle modality specificity. The MTF module utilizes mutual attention mechanisms and an uncertainty calibrator to fuse modality features based on modality uncertainty and then fuse the segmentation results under the guidance of Dempster-Shafer Theory. Besides, a new uncertainty perceptual loss is introduced to force the model focusing on uncertain features and hence improve its ability to extract trusted modality information. Extensive comparative experiments are conducted on two publicly available PET/CT datasets to evaluate the performance of our proposed method whose results demonstrate that our MEFN significantly outperforms state-of-the-art methods with improvements of 2.15% and 3.23% in DSC scores on the AutoPET dataset and the Hecktor dataset, respectively. More importantly, our model can provide radiologists with credible uncertainty of the segmentation results for their decision in accepting or rejecting the automatic segmentation results, which is particularly important for clinical applications. Our code will be available at https://github.com/QPaws/MEFN.

  • 5 authors
·
Jun 26, 2024

Calibration and Uncertainty for multiRater Volume Assessment in multiorgan Segmentation (CURVAS) challenge results

Deep learning (DL) has become the dominant approach for medical image segmentation, yet ensuring the reliability and clinical applicability of these models requires addressing key challenges such as annotation variability, calibration, and uncertainty estimation. This is why we created the Calibration and Uncertainty for multiRater Volume Assessment in multiorgan Segmentation (CURVAS), which highlights the critical role of multiple annotators in establishing a more comprehensive ground truth, emphasizing that segmentation is inherently subjective and that leveraging inter-annotator variability is essential for robust model evaluation. Seven teams participated in the challenge, submitting a variety of DL models evaluated using metrics such as Dice Similarity Coefficient (DSC), Expected Calibration Error (ECE), and Continuous Ranked Probability Score (CRPS). By incorporating consensus and dissensus ground truth, we assess how DL models handle uncertainty and whether their confidence estimates align with true segmentation performance. Our findings reinforce the importance of well-calibrated models, as better calibration is strongly correlated with the quality of the results. Furthermore, we demonstrate that segmentation models trained on diverse datasets and enriched with pre-trained knowledge exhibit greater robustness, particularly in cases deviating from standard anatomical structures. Notably, the best-performing models achieved high DSC and well-calibrated uncertainty estimates. This work underscores the need for multi-annotator ground truth, thorough calibration assessments, and uncertainty-aware evaluations to develop trustworthy and clinically reliable DL-based medical image segmentation models.

  • 32 authors
·
May 13, 2025

Performance of a Deep Learning-Based Segmentation Model for Pancreatic Tumors on Public Endoscopic Ultrasound Datasets

Background: Pancreatic cancer is one of the most aggressive cancers, with poor survival rates. Endoscopic ultrasound (EUS) is a key diagnostic modality, but its effectiveness is constrained by operator subjectivity. This study evaluates a Vision Transformer-based deep learning segmentation model for pancreatic tumors. Methods: A segmentation model using the USFM framework with a Vision Transformer backbone was trained and validated with 17,367 EUS images (from two public datasets) in 5-fold cross-validation. The model was tested on an independent dataset of 350 EUS images from another public dataset, manually segmented by radiologists. Preprocessing included grayscale conversion, cropping, and resizing to 512x512 pixels. Metrics included Dice similarity coefficient (DSC), intersection over union (IoU), sensitivity, specificity, and accuracy. Results: In 5-fold cross-validation, the model achieved a mean DSC of 0.651 +/- 0.738, IoU of 0.579 +/- 0.658, sensitivity of 69.8%, specificity of 98.8%, and accuracy of 97.5%. For the external validation set, the model achieved a DSC of 0.657 (95% CI: 0.634-0.769), IoU of 0.614 (95% CI: 0.590-0.689), sensitivity of 71.8%, and specificity of 97.7%. Results were consistent, but 9.7% of cases exhibited erroneous multiple predictions. Conclusions: The Vision Transformer-based model demonstrated strong performance for pancreatic tumor segmentation in EUS images. However, dataset heterogeneity and limited external validation highlight the need for further refinement, standardization, and prospective studies.

  • 14 authors
·
Jan 9

Evaluating Sugarcane Yield Variability with UAV-Derived Cane Height under Different Water and Nitrogen Conditions

This study investigates the relationship between sugarcane yield and cane height derived under different water and nitrogen conditions from pre-harvest Digital Surface Model (DSM) obtained via Unmanned Aerial Vehicle (UAV) flights over a sugarcane test farm. The farm was divided into 62 blocks based on three water levels (low, medium, and high) and three nitrogen levels (low, medium, and high), with repeated treatments. In pixel distribution of DSM for each block, it provided bimodal distribution representing two peaks, ground level (gaps within canopies) and top of the canopies respectively. Using bimodal distribution, mean cane height was extracted for each block by applying a trimmed mean to the pixel distribution, focusing on the top canopy points. Similarly, the extracted mean elevation of the base was derived from the bottom points, representing ground level. The Derived Cane Height Model (DCHM) was generated by taking the difference between the mean canopy height and mean base elevation for each block. Yield measurements (tons/acre) were recorded post-harvest for each block. By aggregating the data into nine treatment zones (e.g., high water-low nitrogen, low water-high nitrogen), the DCHM and median yield were calculated for each zone. The regression analysis between the DCHM and corresponding yields for the different treatment zones yielded an R 2 of 0.95. This study demonstrates the significant impact of water and nitrogen treatments on sugarcane height and yield, utilizing one-time UAV-derived DSM data.

  • 5 authors
·
Oct 28, 2024