new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Apr 2

Automated SSIM Regression for Detection and Quantification of Motion Artefacts in Brain MR Images

Motion artefacts in magnetic resonance brain images can have a strong impact on diagnostic confidence. The assessment of MR image quality is fundamental before proceeding with the clinical diagnosis. Motion artefacts can alter the delineation of structures such as the brain, lesions or tumours and may require a repeat scan. Otherwise, an inaccurate (e.g. correct pathology but wrong severity) or incorrect diagnosis (e.g. wrong pathology) may occur. "Image quality assessment" as a fast, automated step right after scanning can assist in deciding if the acquired images are diagnostically sufficient. An automated image quality assessment based on the structural similarity index (SSIM) regression through a residual neural network is proposed in this work. Additionally, a classification into different groups - by subdividing with SSIM ranges - is evaluated. Importantly, this method predicts SSIM values of an input image in the absence of a reference ground truth image. The networks were able to detect motion artefacts, and the best performance for the regression and classification task has always been achieved with ResNet-18 with contrast augmentation. The mean and standard deviation of residuals' distribution were mu=-0.0009 and sigma=0.0139, respectively. Whilst for the classification task in 3, 5 and 10 classes, the best accuracies were 97, 95 and 89\%, respectively. The results show that the proposed method could be a tool for supporting neuro-radiologists and radiographers in evaluating image quality quickly.

  • 7 authors
·
Jun 14, 2022

Sentinel: A Hyper-Heuristic for the Generation of Mutant Reduction Strategies

Mutation testing is an effective approach to evaluate and strengthen software test suites, but its adoption is currently limited by the mutants' execution computational cost. Several strategies have been proposed to reduce this cost (a.k.a. mutation cost reduction strategies), however none of them has proven to be effective for all scenarios since they often need an ad-hoc manual selection and configuration depending on the software under test (SUT). In this paper, we propose a novel multi-objective evolutionary hyper-heuristic approach, dubbed Sentinel, to automate the generation of optimal cost reduction strategies for every new SUT. We evaluate Sentinel by carrying out a thorough empirical study involving 40 releases of 10 open-source real-world software systems and both baseline and state-of-the-art strategies as a benchmark. We execute a total of 4,800 experiments, and evaluate their results with both quality indicators and statistical significance tests, following the most recent best practice in the literature. The results show that strategies generated by Sentinel outperform the baseline strategies in 95% of the cases always with large effect sizes. They also obtain statistically significantly better results than state-of-the-art strategies in 88% of the cases, with large effect sizes for 95% of them. Also, our study reveals that the mutation strategies generated by Sentinel for a given software version can be used without any loss in quality for subsequently developed versions in 95% of the cases. These results show that Sentinel is able to automatically generate mutation strategies that reduce mutation testing cost without affecting its testing effectiveness (i.e. mutation score), thus taking off from the tester's shoulders the burden of manually selecting and configuring strategies for each SUT.

  • 4 authors
·
Mar 12, 2021

Diagnostic Impact of Cine Clips for Thyroid Nodule Assessment on Ultrasound

Background: Thyroid ultrasound is commonly performed using a combination of static images and cine clips (video recordings). However, the exact utility and impact of cine images remains unknown. This study aimed to evaluate the impact of cine imaging on accuracy and consistency of thyroid nodule assessment, using the American College of Radiology Thyroid Reporting and Data System (ACR TI-RADS). Methods: 50 benign and 50 malignant thyroid nodules with cytopathology results were included. A reader study with 4 specialty-trained radiologists was then conducted over 3 rounds, assessing only static images in the first two rounds and both static and cine images in the third round. TI-RADS scores and the consequent management recommendations were then evaluated by comparing them to the malignancy status of the nodules. Results: Mean sensitivity for malignancy detection was 0.65 for static images and 0.67 with both static and cine images (p>0.5). Specificity was 0.20 for static images and 0.22 with both static and cine images (p>0.5). Management recommendations were similar with and without cine images. Intrareader agreement on feature assignments remained consistent across all rounds, though TI-RADS point totals were slightly higher with cine images. Conclusion: The inclusion of cine imaging for thyroid nodule assessment on ultrasound did not significantly change diagnostic performance. Current practice guidelines, which do not mandate cine imaging, are sufficient for accurate diagnosis.

  • 7 authors
·
Jan 31

One Model to Rule them All: Towards Universal Segmentation for Medical Images with Text Prompts

In this study, we aim to build up a model that can Segment Anything in radiology scans, driven by medical terminologies as Text prompts, termed as SAT. Our main contributions are three folds: (i) for dataset construction, we construct the first multi-modal knowledge tree on human anatomy, including 6502 anatomical terminologies; Then, we build up the largest and most comprehensive segmentation dataset for training, by collecting over 22K 3D medical image scans from72 segmentation datasets, across 497 classes, with careful standardization on both image scans and label space; (ii) for architecture design, we propose to inject medical knowledge into a text encoder via contrastive learning, and then formulate a universal segmentation model, that can be prompted by feeding in medical terminologies in text form; (iii) As a result, we have trained SAT-Nano (110M parameters) and SAT-Pro (447M parameters), demonstrating superior or comparable performance to 72 specialist models, i.e., nnU-Nets, U-Mamba or SwinUNETR, trained on each dataset/subsets. We validate SAT as a foundational segmentation model, with better generalization on external (cross-center) datasets, and can be further improved on specific tasks after fine-tuning adaptation. Comparing with state-of-the-art interactive segmentation model MedSAM, SAT demonstrate superior performance, scalability and robustness. We further compare SAT with BiomedParse, and observe SAT is significantly superior in both internal and external evaluation. Through extensive ablation study, we validate the benefit of domain knowledge on universal segmentation, especially on tail categories. As a use case, we demonstrate that SAT can act as a powerful out-of-the-box agent for large language models, enabling visual grounding in versatile application scenarios. All the data, codes, and models in this work have been released.

  • 7 authors
·
Dec 28, 2023