new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Aug 12

Quantisation Reshapes the Metacognitive Geometry of Language Models

We report that model quantisation restructures domain-level metacognitive efficiency in LLMs rather than degrading it uniformly. Evaluating Llama-3-8B-Instruct on the same 3,000 questions at Q5_K_M and f16 precision, we find that M-ratio profiles across four knowledge domains are uncorrelated between formats (Spearman rho = 0.00). Arts & Literature moves from worst-monitored (M-ratio = 0.606 at Q5_K_M) to best-monitored (1.542 at f16). Geography moves from well-monitored (1.210) to under-monitored (0.798). However, Type-2 AUROC profiles are perfectly stable across formats (rho = 1.00), localising the restructuring to the M-ratio normalisation rather than the underlying discrimination signal. This finding emerged from a pre-registered attempt to improve metacognition through domain-conditional training. We prescribed confidence-amplification SFT for the diagnosed weak domain, with matched-budget agnostic and wrong-prescription controls. All four confirmatory hypotheses were null (10,000 bootstrap resamples, seed = 42). The training successfully reshaped confidence distributions, doubling the NLP gap in Science from 0.076 to 0.152, but did not improve meta-d' because the diagnostic profile did not transfer across formats. Any system relying on domain-level M-ratio profiles has an unexamined dependency on inference format. Systems using AUROC_2 are safer. We release all code, pre-registrations, and trial-level data.

  • 1 authors
·
Apr 9

Domain-level metacognitive monitoring in frontier LLMs: A 33-model atlas

Aggregate metacognitive quality scores mask within-model variation across MMLU benchmark domains. We administered 1,500 MMLU items (250 per domain, under an a priori six-domain grouping) to 33 frontier LLMs from eight model families and computed Type-2 AUROC per model-domain cell using verbalized confidence (0-100). Total observations: 47,151. Every model with above-chance aggregate monitoring showed non-trivial domain-level variation. Applied/Professional knowledge was reliably the easiest benchmark domain to monitor (mean AUROC = .742, ranked top-2 in 21 of 33 models); Formal Reasoning and Natural Science were reliably the hardest (one of the two ranked bottom-2 in 27 of 33 models). The three middle domains were statistically indistinguishable (Kendall's W = .164). A subject-level coherence analysis (within-domain similarity ratio = 0.95) confirms the six-domain grouping is a pragmatic benchmark taxonomy, not a validated latent construct. Within-family profile-shape clustering is significant for Anthropic, Google-Gemini, and Qwen (permutation p < .0001) but not DeepSeek, Google-Gemma, or OpenAI. Gemma 4 31B showed a +.202 AUROC improvement over Gemma 3 27B. Three models classified Invalid on binary KEEP/WITHDRAW probes produced normal profiles under verbalized confidence, confirming probe-format specificity. Bootstrap 95% CIs on 198 cells have median width .199. Split-half aggregate stability r = .893; profile-level split-half is weaker (grand median r = .184). These results show stable benchmark-domain variation obscured by aggregate metrics, and support benchmark-stage domain screening as a step before deployment in specific application areas.

  • 1 authors
·
Apr 20

Do LLMs Know What They Know? Measuring Metacognitive Efficiency with Signal Detection Theory

Standard evaluation of LLM confidence relies on calibration metrics (ECE, Brier score) that conflate two distinct capacities: how much a model knows (Type-1 sensitivity) and how well it knows what it knows (Type-2 metacognitive sensitivity). We introduce an evaluation framework based on Type-2 Signal Detection Theory that decomposes these capacities using meta-d' and the metacognitive efficiency ratio M-ratio. Applied to four LLMs (Llama-3-8B-Instruct, Mistral-7B-Instruct-v0.3, Llama-3-8B-Base, Gemma-2-9B-Instruct) across 224,000 factual QA trials, we find: (1) metacognitive efficiency varies substantially across models even when Type-1 sensitivity is similar -- Mistral achieves the highest d' but the lowest M-ratio; (2) metacognitive efficiency is domain-specific, with different models showing different weakest domains, invisible to aggregate metrics; (3) temperature manipulation shifts Type-2 criterion while meta-d' remains stable for two of four models, dissociating confidence policy from metacognitive capacity; (4) AUROC_2 and M-ratio produce fully inverted model rankings, demonstrating these metrics answer fundamentally different evaluation questions. The meta-d' framework reveals which models "know what they don't know" versus which merely appear well-calibrated due to criterion placement -- a distinction with direct implications for model selection, deployment, and human-AI collaboration. Pre-registered analysis; code and data publicly available.

  • 1 authors
·
Mar 25

AEGIS: Assay-Aware Protocol Validation and Runtime Monitoring for Open-Source Liquid Handling Robots

Self-driving laboratories increasingly rely on low-cost liquid handlers such as the Opentrons OT-2, which ship without the pressure-based aspiration monitoring of Hamilton or Tecan systems and are typically run open-loop. Two failure modes go undetected: protocols that are syntactically valid but violate assay-specific invariants (e.g., tip reuse between a PCR template and a no-template control), and physical execution failures (partial dispense, air bubbles, missing tips) at runtime. We present AEGIS, a two-layer guardian for both. Layer 1 pairs a curated machine-readable assay rule database with an LLM that reasons over OT-2 Python code, reaching an adjusted F1 of 0.97 on a 24-protocol benchmark across five assay families and beating rules-only and LLM-only ablations across five backends; a free open-weight model ties the best proprietary one, so no paid API is required. Layer 2 fits a PCA world model to YOLO-cropped four-frame pipette trajectories; under a leakage-free leave-one-plate-out evaluation it reaches average precision 0.89 and operating-point F1 0.71 (AUROC 0.80), a deployment-faithful number that matches the live demonstration, and we characterize the small-pipette (p20) resolution limit (F1 0.47). A live demonstration on a physical OT-2 (five replicates per condition) catches planted no-tip failures deterministically and partial dispense on coloured dyes, with an always-VLM self-vote gate lifting partial-dispense recall to 5/5; transparent water is a principled limit of any front-view-only monitor, which AEGIS surfaces as low-confidence VLM reasoning rather than a wrong verdict. Cascade triage holds VLM cost near 1.63 per plate versus 10.33 for an always-VLM baseline. AEGIS is open source and, to our knowledge, the first system to unify pre-flight assay-aware validation with runtime visual monitoring for an open-source liquid handler.

  • 4 authors
·
Jul 16

A Closer Look at AUROC and AUPRC under Class Imbalance

In machine learning (ML), a widespread adage is that the area under the precision-recall curve (AUPRC) is a superior metric for model comparison to the area under the receiver operating characteristic (AUROC) for binary classification tasks with class imbalance. This paper challenges this notion through novel mathematical analysis, illustrating that AUROC and AUPRC can be concisely related in probabilistic terms. We demonstrate that AUPRC, contrary to popular belief, is not superior in cases of class imbalance and might even be a harmful metric, given its inclination to unduly favor model improvements in subpopulations with more frequent positive labels. This bias can inadvertently heighten algorithmic disparities. Prompted by these insights, a thorough review of existing ML literature was conducted, utilizing large language models to analyze over 1.5 million papers from arXiv. Our investigation focused on the prevalence and substantiation of the purported AUPRC superiority. The results expose a significant deficit in empirical backing and a trend of misattributions that have fuelled the widespread acceptance of AUPRC's supposed advantages. Our findings represent a dual contribution: a significant technical advancement in understanding metric behaviors and a stark warning about unchecked assumptions in the ML community. All experiments are accessible at https://github.com/mmcdermott/AUC_is_all_you_need.

  • 5 authors
·
Jan 11, 2024

Uncertainty quantification for improving radiomic-based models in radiation pneumonitis prediction

Background and Objective: Radiation pneumonitis (RP) is a side effect of thoracic radiation therapy. Recently, Machine learning (ML) models enhanced with radiomic and dosiomic features provide better predictions by incorporating spatial information beyond DVHs. However, to improve the clinical decision process, we propose to use uncertainty quantification (UQ) to improve the confidence in model prediction. This study evaluates the impact of post hoc UQ methods on the discriminative performance and calibration of ML models for RP prediction. Methods: This study evaluated four ML models: logistic regression (LR), support vector machines (SVM), extreme gradient boosting (XGB), and random forest (RF), using radiomic, dosiomic, and dosimetric features to predict RP. We applied UQ methods, including Patt scaling, isotonic regression, Venn-ABERS predictor, and Conformal Prediction, to quantify uncertainty. Model performance was assessed through Area Under the Receiver Operating Characteristic curve (AUROC), Area Under the Precision-Recall Curve (AUPRC), and Adaptive Calibration Error (ACE) using Leave-One-Out Cross-Validation (LOO-CV). Results: UQ methods enhanced predictive performance, particularly for high-certainty predictions, while also improving calibration. Radiomic and dosiomic features increased model accuracy but introduced calibration challenges, especially for non-linear models like XGB and RF. Performance gains from UQ methods were most noticeable at higher certainty thresholds. Conclusion: Integrating UQ into ML models with radiomic and dosiomic features improves both predictive accuracy and calibration, supporting more reliable clinical decision-making. The findings emphasize the value of UQ methods in enhancing applicability of predictive models for RP in healthcare settings.

  • 3 authors
·
Dec 27, 2024

Enhancing clinical decision support with physiological waveforms -- a multimodal benchmark in emergency care

Background: AI-driven prediction algorithms have the potential to enhance emergency medicine by enabling rapid and accurate decision-making regarding patient status and potential deterioration. However, the integration of multimodal data, including raw waveform signals, remains underexplored in clinical decision support. Methods: We present a dataset and benchmarking protocol designed to advance multimodal decision support in emergency care. Our models utilize demographics, biometrics, vital signs, laboratory values, and electrocardiogram (ECG) waveforms as inputs to predict both discharge diagnoses and patient deterioration. Results: The diagnostic model achieves area under the receiver operating curve (AUROC) scores above 0.8 for 609 out of 1,428 conditions, covering both cardiac (e.g., myocardial infarction) and non-cardiac (e.g., renal disease, diabetes) diagnoses. The deterioration model attains AUROC scores above 0.8 for 14 out of 15 targets, accurately predicting critical events such as cardiac arrest, mechanical ventilation, ICU admission, and mortality. Conclusions: Our study highlights the positive impact of incorporating raw waveform data into decision support models, improving predictive performance. By introducing a unique, publicly available dataset and baseline models, we provide a foundation for measurable progress in AI-driven decision support for emergency care.

  • 3 authors
·
Apr 29, 2025

AUPIMO: Redefining Visual Anomaly Detection Benchmarks with High Speed and Low Tolerance

Recent advances in visual anomaly detection research have seen AUROC and AUPRO scores on public benchmark datasets such as MVTec and VisA converge towards perfect recall, giving the impression that these benchmarks are near-solved. However, high AUROC and AUPRO scores do not always reflect qualitative performance, which limits the validity of these metrics in real-world applications. We argue that the artificial ceiling imposed by the lack of an adequate evaluation metric restrains progression of the field, and it is crucial that we revisit the evaluation metrics used to rate our algorithms. In response, we introduce Per-IMage Overlap (PIMO), a novel metric that addresses the shortcomings of AUROC and AUPRO. PIMO retains the recall-based nature of the existing metrics but introduces two distinctions: the assignment of curves (and respective area under the curve) is per-image, and its X-axis relies solely on normal images. Measuring recall per image simplifies instance score indexing and is more robust to noisy annotations. As we show, it also accelerates computation and enables the usage of statistical tests to compare models. By imposing low tolerance for false positives on normal images, PIMO provides an enhanced model validation procedure and highlights performance variations across datasets. Our experiments demonstrate that PIMO offers practical advantages and nuanced performance insights that redefine anomaly detection benchmarks -- notably challenging the perception that MVTec AD and VisA datasets have been solved by contemporary models. Available on GitHub: https://github.com/jpcbertoldo/aupimo.

  • 4 authors
·
Jan 3, 2024

Deep Learning-Based Breast Cancer Detection in Mammography: A Multi-Center Validation Study in Thai Population

This study presents a deep learning system for breast cancer detection in mammography, developed using a modified EfficientNetV2 architecture with enhanced attention mechanisms. The model was trained on mammograms from a major Thai medical center and validated on three distinct datasets: an in-domain test set (9,421 cases), a biopsy-confirmed set (883 cases), and an out-of-domain generalizability set (761 cases) collected from two different hospitals. For cancer detection, the model achieved AUROCs of 0.89, 0.96, and 0.94 on the respective datasets. The system's lesion localization capability, evaluated using metrics including Lesion Localization Fraction (LLF) and Non-Lesion Localization Fraction (NLF), demonstrated robust performance in identifying suspicious regions. Clinical validation through concordance tests showed strong agreement with radiologists: 83.5% classification and 84.0% localization concordance for biopsy-confirmed cases, and 78.1% classification and 79.6% localization concordance for out-of-domain cases. Expert radiologists' acceptance rate also averaged 96.7% for biopsy-confirmed cases, and 89.3% for out-of-domain cases. The system achieved a System Usability Scale score of 74.17 for source hospital, and 69.20 for validation hospitals, indicating good clinical acceptance. These results demonstrate the model's effectiveness in assisting mammogram interpretation, with the potential to enhance breast cancer screening workflows in clinical practice.

  • 15 authors
·
May 29, 2025

Disentanglement and Assessment of Shortcuts in Ophthalmological Retinal Imaging Exams

Diabetic retinopathy (DR) is a leading cause of vision loss in working-age adults. While screening reduces the risk of blindness, traditional imaging is often costly and inaccessible. Artificial intelligence (AI) algorithms present a scalable diagnostic solution, but concerns regarding fairness and generalization persist. This work evaluates the fairness and performance of image-trained models in DR prediction, as well as the impact of disentanglement as a bias mitigation technique, using the diverse mBRSET fundus dataset. Three models, ConvNeXt V2, DINOv2, and Swin V2, were trained on macula images to predict DR and sensitive attributes (SAs) (e.g., age and gender/sex). Fairness was assessed between subgroups of SAs, and disentanglement was applied to reduce bias. All models achieved high DR prediction performance in diagnosing (up to 94% AUROC) and could reasonably predict age and gender/sex (91% and 77% AUROC, respectively). Fairness assessment suggests disparities, such as a 10% AUROC gap between age groups in DINOv2. Disentangling SAs from DR prediction had varying results, depending on the model selected. Disentanglement improved DINOv2 performance (2% AUROC gain), but led to performance drops in ConvNeXt V2 and Swin V2 (7% and 3%, respectively). These findings highlight the complexity of disentangling fine-grained features in fundus imaging and emphasize the importance of fairness in medical imaging AI to ensure equitable and reliable healthcare solutions.

  • 5 authors
·
Jul 13, 2025

Pillar-0: A New Frontier for Radiology Foundation Models

Radiology plays an integral role in modern medicine, yet rising imaging volumes have far outpaced workforce growth. Foundation models offer a path toward assisting with the full spectrum of radiology tasks, but existing medical models remain limited: they process volumetric CT and MRI as low-fidelity 2D slices, discard critical grayscale contrast information, and lack evaluation frameworks that reflect real clinical practice. We introduce Pillar-0, a radiology foundation model pretrained on 42,990 abdomen-pelvis CTs, 86,411 chest CTs, 14,348 head CTs, and 11,543 breast MRIs from a large academic center, together with RATE, a scalable framework that extracts structured labels for 366 radiologic findings with near-perfect accuracy using LLMs. Across internal test sets of 14,230 abdomen-pelvis CTs, 10,646 chest CTs, 4,906 head CTs, and 1,585 breast MRIs, Pillar-0 establishes a new performance frontier, achieving mean AUROCs of 86.4, 88.0, 90.1, and 82.9, outperforming MedGemma (Google), MedImageInsight (Microsoft), Lingshu (Alibaba), and Merlin (Stanford) by 7.8-15.8 AUROC points and ranking best in 87.2\% (319/366) tasks. Pillar-0 similarly outperforms all baselines in an external validation on the Stanford Abdominal CT dataset, including Merlin (82.2 vs 80.6 AUROC). Pillar-0 extends to tasks beyond its pretraining, such as long-horizon lung cancer risk prediction, where it improves upon the state-of-the-art Sybil by 3.0 C-index points on NLST, and generalizes with gains of 5.9 (MGH) and 1.9 (CGMH). In brain hemorrhage detection, Pillar-0 obtained a >95 AUROC when using only 1/20th of the data of the next most sample efficient baseline. Pillar-0 and RATE together provide an open, clinically rigorous foundation for building high-performance radiology systems, enabling applications that were previously infeasible due to computational, data, and evaluation constraints.

YalaLab Yala Lab
·
Nov 21, 2025 2

Pressure-Testing Deception Probes in LLMs: Scaling, Robustness, and the Geometry of Deceptive Representations

Linear probes trained on LLM activations are increasingly proposed as deception-detection metrics, yet report AUROC exceeding 0.96 on clean benchmarks while collapsing under distributional shift. This paper systematically pressure-tests probe-based metrics across the Gemma 3 model family (1B-27B parameters), diagnosing why they fail rather than merely documenting that they fail. We test four hypotheses about deception encoding: (1) single linear direction, (2) multi-dimensional subspace, (3) convex conic hull, (4) entropy proxy. Our design includes cross-domain transfer matrices, multi-dimensional probe analysis with permutation null baselines, entropy-residualization tests, and distractor evaluations across 8 stylistic shifts. We find that: (a) probes achieve near-perfect AUROC (>=0.998) on clean data but collapse under stylistic shifts; style-augmented probes recover near-perfect detection (mean AUROC 0.979-0.983) on unseen styles; (b) the single-direction hypothesis is rejected (k=1 captures only 0.61-0.80 AUROC), with cross-domain transfer failure confirmed as geometric rather than layer-mismatch-driven; (c) the entropy-proxy hypothesis is rejected (max |rho|=0.454, max Delta-AUROC after residualization=0.004); and (d) deception does not form a significant linear subspace (per-domain k*=0), yet multi-dimensional probes (k>=5) recover the signal through distributed sub-threshold features. Probe fragility reflects distributional narrowness rather than an architectural limitation: style-augmented probes recover near-perfect detection at both 4B and 27B, establishing that the inverse scaling pattern is a training-distribution artifact rather than a genuine scale-dependent phenomenon.

  • 1 authors
·
May 27 2