new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Aug 27

Remote Bio-Sensing: Open Source Benchmark Framework for Fair Evaluation of rPPG

rPPG (Remote photoplethysmography) is a technology that measures and analyzes BVP (Blood Volume Pulse) by using the light absorption characteristics of hemoglobin captured through a camera. Analyzing the measured BVP can derive various physiological signals such as heart rate, stress level, and blood pressure, which can be applied to various applications such as telemedicine, remote patient monitoring, and early prediction of cardiovascular disease. rPPG is rapidly evolving and attracting great attention from both academia and industry by providing great usability and convenience as it can measure biosignals using a camera-equipped device without medical or wearable devices. Despite extensive efforts and advances in this field, serious challenges remain, including issues related to skin color, camera characteristics, ambient lighting, and other sources of noise and artifacts, which degrade accuracy performance. We argue that fair and evaluable benchmarking is urgently required to overcome these challenges and make meaningful progress from both academic and commercial perspectives. In most existing work, models are trained, tested, and validated only on limited datasets. Even worse, some studies lack available code or reproducibility, making it difficult to fairly evaluate and compare performance. Therefore, the purpose of this study is to provide a benchmarking framework to evaluate various rPPG techniques across a wide range of datasets for fair evaluation and comparison, including both conventional non-deep neural network (non-DNN) and deep neural network (DNN) methods. GitHub URL: https://github.com/remotebiosensing/rppg

  • 8 authors
·
Aug 17, 2023

Tiny-BioMoE: a Lightweight Embedding Model for Biosignal Analysis

Pain is a complex and pervasive condition that affects a significant portion of the population. Accurate and consistent assessment is essential for individuals suffering from pain, as well as for developing effective management strategies in a healthcare system. Automatic pain assessment systems enable continuous monitoring, support clinical decision-making, and help minimize patient distress while mitigating the risk of functional deterioration. Leveraging physiological signals offers objective and precise insights into a person's state, and their integration in a multimodal framework can further enhance system performance. This study has been submitted to the Second Multimodal Sensing Grand Challenge for Next-Gen Pain Assessment (AI4PAIN). The proposed approach introduces Tiny-BioMoE, a lightweight pretrained embedding model for biosignal analysis. Trained on 4.4 million biosignal image representations and consisting of only 7.3 million parameters, it serves as an effective tool for extracting high-quality embeddings for downstream tasks. Extensive experiments involving electrodermal activity, blood volume pulse, respiratory signals, peripheral oxygen saturation, and their combinations highlight the model's effectiveness across diverse modalities in automatic pain recognition tasks. The model's architecture (code) and weights are available at https://github.com/GkikasStefanos/Tiny-BioMoE.

  • 3 authors
·
Jul 29, 2025

EgoHRV: Continuous Heart Rate Variability Estimation from Egocentric Systems for Autonomic Response and Skill Assessment

Egocentric vision systems capture human behavior from visible cues, but overlook physiological indicators of autonomic states such as stress, engagement, and attention. Heart rate variability (HRV) is a widely used noninvasive marker of autonomic regulation under stress. HRV reflects small timing differences between successive heartbeats and has so far been out of reach for egocentric platforms, where motion and noise in gaze video mask exactly this fine-grained timing. We propose EgoHRV, a method that estimates HRV as well as heart rate (HR) from the gaze cameras that are already integrated into egocentric headsets. Our pipeline combines a 3D backbone with a novel low--high decomposition module that extracts the blood volume pulse (BVP) signal from gaze video. Our cross-domain pretraining aligns the frequency-domain representations of contact-based and camera-derived signals. This alignment gives EgoHRV the temporal precision to recover HRV from the subtle fluctuations in gaze video. EgoHRV achieves state-of-the-art accuracy for HR and HRV estimation from egocentric video, and its uncertainty-aware design improves downstream behavioral modeling. Integrating our HRV estimates and confidence measures into EgoExo4D's proficiency estimator raises accuracy by 17.8%. Beyond skill, continuous HRV estimation also opens egocentric systems to stress- and arousal-aware estimation tasks. Code: https://github.com/eth-siplab/EgoHRV

  • 2 authors
·
Aug 18

Robust and Generalizable Heart Rate Estimation via Deep Learning for Remote Photoplethysmography in Complex Scenarios

Non-contact remote photoplethysmography (rPPG) technology enables heart rate measurement from facial videos. However, existing network models still face challenges in accu racy, robustness, and generalization capability under complex scenarios. This paper proposes an end-to-end rPPG extraction network that employs 3D convolutional neural networks to reconstruct accurate rPPG signals from raw facial videos. We introduce a differential frame fusion module that integrates differential frames with original frames, enabling frame-level representations to capture blood volume pulse (BVP) variations. Additionally, we incorporate Temporal Shift Module (TSM) with self-attention mechanisms, which effectively enhance rPPG features with minimal computational overhead. Furthermore, we propose a novel dynamic hybrid loss function that provides stronger supervision for the network, effectively mitigating over fitting. Comprehensive experiments were conducted on not only the PURE and UBFC-rPPG datasets but also the challenging MMPD dataset under complex scenarios, involving both intra dataset and cross-dataset evaluations, which demonstrate the superior robustness and generalization capability of our network. Specifically, after training on PURE, our model achieved a mean absolute error (MAE) of 7.58 on the MMPD test set, outperforming the state-of-the-art models.

  • 3 authors
·
Jul 10, 2025

A Hybrid Deep Learning Model for Robust Biometric Authentication from Low-Frame-Rate PPG Signals

Photoplethysmography (PPG) signals, which measure changes in blood volume in the skin using light, have recently gained attention in biometric authentication because of their non-invasive acquisition, inherent liveness detection, and suitability for low-cost wearable devices. However, PPG signal quality is challenged by motion artifacts, illumination changes, and inter-subject physiological variability, making robust feature extraction and classification crucial. This study proposes a lightweight and cost-effective biometric authentication framework based on PPG signals extracted from low-frame-rate fingertip videos. The CFIHSR dataset, comprising PPG recordings from 46 subjects at a sampling rate of 14 Hz, is employed for evaluation. The raw PPG signals undergo a standard preprocessing pipeline involving baseline drift removal, motion artifact suppression using Principal Component Analysis (PCA), bandpass filtering, Fourier-based resampling, and amplitude normalization. To generate robust representations, each one-dimensional PPG segment is converted into a two-dimensional time-frequency scalogram via the Continuous Wavelet Transform (CWT), effectively capturing transient cardiovascular dynamics. We developed a hybrid deep learning model, termed CVT-ConvMixer-LSTM, by combining spatial features from the Convolutional Vision Transformer (CVT) and ConvMixer branches with temporal features from a Long Short-Term Memory network (LSTM). The experimental results on 46 subjects demonstrate an authentication accuracy of 98%, validating the robustness of the model to noise and variability between subjects. Due to its efficiency, scalability, and inherent liveness detection capability, the proposed system is well-suited for real-world mobile and embedded biometric security applications.

  • 2 authors
·
Nov 5, 2025

Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video

Human health can be critically affected by cardiovascular diseases, such as hypertension, arrhythmias, and stroke. Heart rate and blood pressure are important biometric information for the monitoring of cardiovascular system and early diagnosis of cardiovascular diseases. Existing methods for estimating the heart rate are based on electrocardiography and photoplethyomography, which require contacting the sensor to the skin surface. Moreover, catheter and cuff-based methods for measuring blood pressure cause inconvenience and have limited applicability. Therefore, in this thesis, we propose a vision-based method for estimating the heart rate and blood pressure. This thesis proposes a 2-stage deep learning framework consisting of a dual remote photoplethysmography network (DRP-Net) and bounded blood pressure network (BBP-Net). In the first stage, DRP-Net infers remote photoplethysmography (rPPG) signals for the acral and facial regions, and these phase-shifted rPPG signals are utilized to estimate the heart rate. In the second stage, BBP-Net integrates temporal features and analyzes phase discrepancy between the acral and facial rPPG signals to estimate SBP and DBP values. To improve the accuracy of estimating the heart rate, we employed a data augmentation method based on a frame interpolation model. Moreover, we designed BBP-Net to infer blood pressure within a predefined range by incorporating a scaled sigmoid function. Our method resulted in estimating the heart rate with the mean absolute error (MAE) of 1.78 BPM, reducing the MAE by 34.31 % compared to the recent method, on the MMSE-HR dataset. The MAE for estimating the systolic blood pressure (SBP) and diastolic blood pressure (DBP) were 10.19 mmHg and 7.09 mmHg. On the V4V dataset, the MAE for the heart rate, SBP, and DBP were 3.83 BPM, 13.64 mmHg, and 9.4 mmHg, respectively.

  • 2 authors
·
Jan 9, 2024

Artificial Intelligence-derived Vascular Age from Photoplethysmography: A Novel Digital Biomarker for Cardiovascular Health

With the increasing availability of wearable devices, photoplethysmography (PPG) has emerged as a promising non-invasive tool for monitoring human hemodynamics. We propose a deep learning framework to estimate vascular age (AI-vascular age) from PPG signals, incorporating a distribution-aware loss to address biases caused by imbalanced data. The model was developed using data from the UK Biobank (UKB), with 98,672 participants in the development cohort and 113,559 participants (144,683 data pairs) for clinical evaluation. After adjusting for key confounders, individuals with a vascular age gap (AI-vascular age minus calendar age) exceeding 9 years had a significantly higher risk of major adverse cardiovascular and cerebrovascular events (MACCE) (HR = 2.37, p < 0.005) and secondary outcomes, including diabetes (HR = 2.69, p < 0.005), hypertension (HR = 2.88, p < 0.005), coronary heart disease (HR = 2.20, p < 0.005), heart failure (HR = 2.15, p < 0.005), myocardial infarction (HR = 2.51, p < 0.005), stroke (HR = 2.55, p < 0.005), and all-cause mortality (HR = 2.51, p < 0.005). Conversely, participants with a vascular age gap below -9 years exhibited a significantly lower incidence of these outcomes. We further evaluated the longitudinal applicability of AI-vascular age using serial PPG data from the UKB, demonstrating its value in risk stratification by leveraging AI-vascular age at two distinct time points to predict future MACCE incidence. External validation was performed on a MIMIC-III-derived cohort (n = 2,343), where each one-year increase in vascular age gap was significantly associated with elevated in-hospital mortality risk (OR = 1.02, p < 0.005). In conclusion, our study establishes AI-vascular age as a novel, non-invasive digital biomarker for cardiovascular health assessment.

  • 5 authors
·
Feb 18, 2025

From time-series to complex networks: Application to the cerebrovascular flow patterns in atrial fibrillation

A network-based approach is presented to investigate the cerebrovascular flow patterns during atrial fibrillation (AF) with respect to normal sinus rhythm (NSR). AF, the most common cardiac arrhythmia with faster and irregular beating, has been recently and independently associated with the increased risk of dementia. However, the underlying hemodynamic mechanisms relating the two pathologies remain mainly undetermined so far; thus the contribution of modeling and refined statistical tools is valuable. Pressure and flow rate temporal series in NSR and AF are here evaluated along representative cerebral sites (from carotid arteries to capillary brain circulation), exploiting reliable artificially built signals recently obtained from an in silico approach. The complex network analysis evidences, in a synthetic and original way, a dramatic signal variation towards the distal/capillary cerebral regions during AF, which has no counterpart in NSR conditions. At the large artery level, networks obtained from both AF and NSR hemodynamic signals exhibit elongated and chained features, which are typical of pseudo-periodic series. These aspects are almost completely lost towards the microcirculation during AF, where the networks are topologically more circular and present random-like characteristics. As a consequence, all the physiological phenomena at microcerebral level ruled by periodicity - such as regular perfusion, mean pressure per beat, and average nutrient supply at cellular level - can be strongly compromised, since the AF hemodynamic signals assume irregular behaviour and random-like features. Through a powerful approach which is complementary to the classical statistical tools, the present findings further strengthen the potential link between AF hemodynamic and cognitive decline.

  • 3 authors
·
Sep 26, 2017

Learning from Two Decades of Blood Pressure Data: Demography-Specific Patterns Across 75 Million Patient Encounters

Hypertension remains a global health concern with a rising prevalence, necessitating effective monitoring and understanding of blood pressure (BP) dynamics. This study delves into the wealth of information derived from BP measurement, a crucial approach in informing our understanding of hypertensive trends. Numerous studies have reported on the relationship between BP variation and various factors. In this research, we leveraged an extensive dataset comprising 75 million records spanning two decades, offering a unique opportunity to explore and analyze BP variations across demographic features such as age, race, and gender. Our findings revealed that gender-based BP variation was not statistically significant, challenging conventional assumptions. Interestingly, systolic blood pressure (SBP) consistently increased with age, while diastolic blood pressure (DBP) displayed a distinctive peak in the forties age group. Moreover, our analysis uncovered intriguing similarities in the distribution of BP among some of the racial groups. This comprehensive investigation contributes to the ongoing discourse on hypertension and underscores the importance of considering diverse demographic factors in understanding BP variations. Our results provide valuable insights that may inform personalized healthcare approaches tailored to specific demographic profiles.

  • 4 authors
·
Feb 2, 2024

Reliable Physiological Monitoring on the Wrist Using Generative Deep Learning to Address Poor Skin-Sensor Contact

Photoplethysmography (PPG) is a widely adopted, non-invasive technique for monitoring cardiovascular health and physiological parameters in both consumer and clinical settings. While motion artifacts in dynamic environments have been extensively studied, suboptimal skin-sensor contact in sedentary conditions - a critical yet underexplored issue - can distort PPG waveform morphology, leading to the loss or misalignment of key features and compromising sensing accuracy. In this work, we propose CP-PPG, a novel framework that transforms Contact Pressure-distorted PPG signals into high-fidelity waveforms with ideal morphology. CP-PPG integrates a custom data collection protocol, a carefully designed signal processing pipeline, and a novel deep adversarial model trained with a custom PPG-aware loss function. We validated CP-PPG through comprehensive evaluations, including 1) morphology transformation performance on our self-collected dataset, 2) downstream physiological monitoring performance on public datasets, and 3) in-the-wild study. Extensive experiments demonstrate substantial and consistent improvements in signal fidelity (Mean Absolute Error: 0.09, 40% improvement over the original signal) as well as downstream performance across all evaluations in Heart Rate (HR), Heart Rate Variability (HRV), Respiration Rate (RR), and Blood Pressure (BP) estimation (on average, 21% improvement in HR; 41-46% in HRV; 6% in RR; and 4-5% in BP). These findings highlight the critical importance of addressing skin-sensor contact issues to enhance the reliability and effectiveness of PPG-based physiological monitoring. CP-PPG thus holds significant potential to improve the accuracy of wearable health technologies in clinical and consumer applications.

  • 6 authors
·
Apr 15, 2025

Large Language Models for Cuffless Blood Pressure Measurement From Wearable Biosignals

Large language models (LLMs) have captured significant interest from both academia and industry due to their impressive performance across various textual tasks. However, the potential of LLMs to analyze physiological time-series data remains an emerging research field. Particularly, there is a notable gap in the utilization of LLMs for analyzing wearable biosignals to achieve cuffless blood pressure (BP) measurement, which is critical for the management of cardiovascular diseases. This paper presents the first work to explore the capacity of LLMs to perform cuffless BP estimation based on wearable biosignals. We extracted physiological features from electrocardiogram (ECG) and photoplethysmogram (PPG) signals and designed context-enhanced prompts by combining these features with BP domain knowledge and user information. Subsequently, we adapted LLMs to BP estimation tasks through fine-tuning. To evaluate the proposed approach, we conducted assessments of ten advanced LLMs using a comprehensive public dataset of wearable biosignals from 1,272 participants. The experimental results demonstrate that the optimally fine-tuned LLM significantly surpasses conventional task-specific baselines, achieving an estimation error of 0.00 pm 9.25 mmHg for systolic BP and 1.29 pm 6.37 mmHg for diastolic BP. Notably, the ablation studies highlight the benefits of our context enhancement strategy, leading to an 8.9% reduction in mean absolute error for systolic BP estimation. This paper pioneers the exploration of LLMs for cuffless BP measurement, providing a potential solution to enhance the accuracy of cuffless BP measurement.

  • 8 authors
·
Jun 26, 2024

Change Point--Aware Evaluation and Re-Calibration of PPG-Based Blood Pressure Estimation

Non-invasive continuous blood pressure (BP) monitoring using photoplethysmography (PPG) is a promising alternative to cuff-based measurements. However, existing PPG-based BP estimation studies predominantly rely on aggregated performance metrics (e.g., mean absolute error) computed over entire evaluation intervals, which can obscure model failures during rapid BP fluctuations and limit clinical relevance. In this work, we propose a fluctuation-aware evaluation framework for PPG-based BP estimation based on time-series change point detection. Instead of heuristic BP thresholding (e.g., ΔBP > 10mmHg), we identify BP change points by capturing abrupt distributional shifts in BP trajectories and evaluate estimation performance specifically during these fluctuation periods. Our analysis shows that several state-of-the-art models exhibit substantial performance degradation around BP change points, and that periodic test-time calibration is insufficient to handle such dynamic BP variations. To address this limitation, we introduce a targeted re-calibration framework triggered by detected BP change points, improving robustness without modifying model architectures. To the best of our knowledge, this is the first systematic evaluation of PPG-based BP estimation from a BP change point perspective, highlighting the importance of fluctuation-aware evaluation and calibration for real-world continuous BP monitoring.

  • 5 authors
·
Aug 18

QualityFM: a Multimodal Physiological Signal Foundation Model with Self-Distillation for Signal Quality Challenges in Critically Ill Patients

Photoplethysmogram (PPG) and electrocardiogram (ECG) are commonly recorded in intesive care unit (ICU) and operating room (OR). However, the high incidence of poor, incomplete, and inconsistent signal quality, can lead to false alarms or diagnostic inaccuracies. The methods explored so far suffer from limited generalizability, reliance on extensive labeled data, and poor cross-task transferability. To overcome these challenges, we introduce QualityFM, a novel multimodal foundation model for these physiological signals, designed to acquire a general-purpose understanding of signal quality. Our model is pre-trained on an large-scale dataset comprising over 21 million 30-second waveforms and 179,757 hours of data. Our approach involves a dual-track architecture that processes paired physiological signals of differing quality, leveraging a self-distillation strategy where an encoder for high-quality signals is used to guide the training of an encoder for low-quality signals. To efficiently handle long sequential signals and capture essential local quasi-periodic patterns, we integrate a windowed sparse attention mechanism within our Transformer-based model. Furthermore, a composite loss function, which combines direct distillation loss on encoder outputs with indirect reconstruction loss based on power and phase spectra, ensures the preservation of frequency-domain characteristics of the signals. We pre-train three models with varying parameter counts (9.6 M to 319 M) and demonstrate their efficacy and practical value through transfer learning on three distinct clinical tasks: false alarm of ventricular tachycardia detection, the identification of atrial fibrillation and the estimation of arterial blood pressure (ABP) from PPG and ECG signals.

  • 3 authors
·
Sep 8, 2025

Aortic Valve Disease Detection from PPG via Physiology-Informed Self-Supervised Learning

Traditional diagnosis of aortic valve disease relies on echocardiography, but its cost and required expertise limit its use in large-scale early screening. Photoplethysmography (PPG) has emerged as a promising screening modality due to its widespread availability in wearable devices and its ability to reflect underlying hemodynamic dynamics. However, the extreme scarcity of gold-standard labeled PPG data severely constrains the effectiveness of data-driven approaches. To address this challenge, we propose and validate a new paradigm, Physiology-Guided Self-Supervised Learning (PG-SSL), aimed at unlocking the value of large-scale unlabeled PPG data for efficient screening of Aortic Stenosis (AS) and Aortic Regurgitation (AR). Using over 170,000 unlabeled PPG samples from the UK Biobank, we formalize clinical knowledge into a set of PPG morphological phenotypes and construct a pulse pattern recognition proxy task for self-supervised pre-training. A dual-branch, gated-fusion architecture is then employed for efficient fine-tuning on a small labeled subset. The proposed PG-SSL framework achieves AUCs of 0.765 and 0.776 for AS and AR screening, respectively, significantly outperforming supervised baselines trained on limited labeled data. Multivariable analysis further validates the model output as an independent digital biomarker with sustained prognostic value after adjustment for standard clinical risk factors. This study demonstrates that PG-SSL provides an effective, domain knowledge-driven solution to label scarcity in medical artificial intelligence and shows strong potential for enabling low-cost, large-scale early screening of aortic valve disease.

  • 7 authors
·
Feb 3

ALPHA: AnomaLous Physiological Health Assessment Using Large Language Models

This study concentrates on evaluating the efficacy of Large Language Models (LLMs) in healthcare, with a specific focus on their application in personal anomalous health monitoring. Our research primarily investigates the capabilities of LLMs in interpreting and analyzing physiological data obtained from FDA-approved devices. We conducted an extensive analysis using anomalous physiological data gathered in a simulated low-air-pressure plateau environment. This allowed us to assess the precision and reliability of LLMs in understanding and evaluating users' health status with notable specificity. Our findings reveal that LLMs exhibit exceptional performance in determining medical indicators, including a Mean Absolute Error (MAE) of less than 1 beat per minute for heart rate and less than 1% for oxygen saturation (SpO2). Furthermore, the Mean Absolute Percentage Error (MAPE) for these evaluations remained below 1%, with the overall accuracy of health assessments surpassing 85%. In image analysis tasks, such as interpreting photoplethysmography (PPG) data, our specially adapted GPT models demonstrated remarkable proficiency, achieving less than 1 bpm error in cycle count and 7.28 MAE for heart rate estimation. This study highlights LLMs' dual role as health data analysis tools and pivotal elements in advanced AI health assistants, offering personalized health insights and recommendations within the future health assistant framework.

  • 7 authors
·
Nov 21, 2023

egoPPG: Heart Rate Estimation from Eye-Tracking Cameras in Egocentric Systems to Benefit Downstream Vision Tasks

Egocentric vision systems aim to understand the spatial surroundings and the wearer's behavior inside it, including motions, activities, and interactions. We argue that egocentric systems must additionally detect physiological states to capture a person's attention and situational responses, which are critical for context-aware behavior modeling. In this paper, we propose egoPPG, a novel vision task for egocentric systems to recover a person's cardiac activity to aid downstream vision tasks. We introduce PulseFormer, a method to extract heart rate as a key indicator of physiological state from the eye tracking cameras on unmodified egocentric vision systems. PulseFormer continuously estimates the photoplethysmogram (PPG) from areas around the eyes and fuses motion cues from the headset's inertial measurement unit to track HR values. We demonstrate egoPPG's downstream benefit for a key task on EgoExo4D, an existing egocentric dataset for which we find PulseFormer's estimates of HR to improve proficiency estimation by 14%. To train and validate PulseFormer, we collected a dataset of 13+ hours of eye tracking videos from Project Aria and contact-based PPG signals as well as an electrocardiogram (ECG) for ground-truth HR values. Similar to EgoExo4D, 25 participants performed diverse everyday activities such as office work, cooking, dancing, and exercising, which induced significant natural motion and HR variation (44-164 bpm). Our model robustly estimates HR (MAE=7.67 bpm) and captures patterns (r=0.85). Our results show how egocentric systems may unify environmental and physiological tracking to better understand users and that egoPPG as a complementary task provides meaningful augmentations for existing datasets and tasks. We release our code, dataset, and HR augmentations for EgoExo4D to inspire research on physiology-aware egocentric tasks.

  • 5 authors
·
Aug 5, 2025

High-Throughput Precision Phenotyping of Left Ventricular Hypertrophy with Cardiovascular Deep Learning

Left ventricular hypertrophy (LVH) results from chronic remodeling caused by a broad range of systemic and cardiovascular disease including hypertension, aortic stenosis, hypertrophic cardiomyopathy, and cardiac amyloidosis. Early detection and characterization of LVH can significantly impact patient care but is limited by under-recognition of hypertrophy, measurement error and variability, and difficulty differentiating etiologies of LVH. To overcome this challenge, we present EchoNet-LVH - a deep learning workflow that automatically quantifies ventricular hypertrophy with precision equal to human experts and predicts etiology of LVH. Trained on 28,201 echocardiogram videos, our model accurately measures intraventricular wall thickness (mean absolute error [MAE] 1.4mm, 95% CI 1.2-1.5mm), left ventricular diameter (MAE 2.4mm, 95% CI 2.2-2.6mm), and posterior wall thickness (MAE 1.2mm, 95% CI 1.1-1.3mm) and classifies cardiac amyloidosis (area under the curve of 0.83) and hypertrophic cardiomyopathy (AUC 0.98) from other etiologies of LVH. In external datasets from independent domestic and international healthcare systems, EchoNet-LVH accurately quantified ventricular parameters (R2 of 0.96 and 0.90 respectively) and detected cardiac amyloidosis (AUC 0.79) and hypertrophic cardiomyopathy (AUC 0.89) on the domestic external validation site. Leveraging measurements across multiple heart beats, our model can more accurately identify subtle changes in LV geometry and its causal etiologies. Compared to human experts, EchoNet-LVH is fully automated, allowing for reproducible, precise measurements, and lays the foundation for precision diagnosis of cardiac hypertrophy. As a resource to promote further innovation, we also make publicly available a large dataset of 23,212 annotated echocardiogram videos.

  • 18 authors
·
Jun 23, 2021

PPGFlowECG: Latent Rectified Flow with Cross-Modal Encoding for PPG-Guided ECG Generation and Cardiovascular Disease Detection

In clinical practice, electrocardiography (ECG) remains the gold standard for cardiac monitoring, providing crucial insights for diagnosing a wide range of cardiovascular diseases (CVDs). However, its reliance on specialized equipment and trained personnel limits feasibility for continuous routine monitoring. Photoplethysmography (PPG) offers accessible, continuous monitoring but lacks definitive electrophysiological information, preventing conclusive diagnosis. Generative models present a promising approach to translate PPG into clinically valuable ECG signals, yet current methods face substantial challenges, including the misalignment of physiological semantics in generative models and the complexity of modeling in high-dimensional signals. To this end, we propose PPGFlowECG, a two-stage framework that aligns PPG and ECG in a shared latent space via the CardioAlign Encoder and employs latent rectified flow to generate ECGs with high fidelity and interpretability. To the best of our knowledge, this is the first study to experiment on MCMED, a newly released clinical-grade dataset comprising over 10 million paired PPG-ECG samples from more than 118,000 emergency department visits with expert-labeled cardiovascular disease annotations. Results demonstrate the effectiveness of our method for PPG-to-ECG translation and cardiovascular disease detection. Moreover, cardiologist-led evaluations confirm that the synthesized ECGs achieve high fidelity and improve diagnostic reliability, underscoring our method's potential for real-world cardiovascular screening.

  • 9 authors
·
Sep 24, 2025

Physiology-Aware Masked Cross-Modal Reconstruction for Biosignal Representation Learning

Biosignals acquired from different locations on the body often provide temporally ordered views of the same underlying physiological process. However, most existing self supervised learning methods treat these signals as interchangeable views, overlooking the directional temporal dynamics that link them. A canonical example is the relationship between electrocardiography (ECG), which captures the electrical activation initiating each heartbeat, and photoplethysmography (PPG), which records the resulting peripheral pulse delayed by vascular dynamics. To capture this structured relationship, we introduce xMAE, a biosignal pretraining framework that leverages masked cross modal reconstruction across temporally ordered biosignals as a training time constraint to encourage physiologically meaningful timing structure in the learned representations. We show that pretraining with xMAE yields representations that outperform both unimodal and multimodal baselines on 15 of 19 downstream tasks, including cardiovascular outcome prediction, abnormal laboratory test detection, sleep staging, and demographic inference, while generalizing across devices, body locations, and acquisition settings. Further analysis suggests that the ECG PPG timing structure is reflected in the learned PPG representations. More broadly, xMAE demonstrates the effectiveness of incorporating temporal structure into multimodal pretraining when signals observe different stages of a shared underlying process. Code is available at https://github.com/hzhou3/xMAE.

  • 15 authors
·
Apr 30

SigmaMedStat: Temporal Signal Modeling for ICU False Alarm Reduction

Alarm fatigue in intensive care units (ICUs) is a well documented patient safety crisis. Clinical monitors generate 350 or more alarms per patient per day, out of which 72-99% are clinically irrelevant. Staff desensitization to non-actionable alarms increases the risk of missed true emergencies. This paper presents SigmaMedStat, a machine learning system that evaluates the trustworthiness of physiological alarm signals before clinical action is taken. Four approaches were evaluated on the PhysioNet/Computing in Cardiology Challenge 2015 dataset of 498 four-channel ICU alarm recordings. Primary contribution is a temporal modeling framework that splits each 60 second recording into six consecutive 10-second chunks, and this in turn generates Continuous Wavelet Transform (CWT) scalograms per chunk, encodes each chunk with a shared EfficientNet-B0 encoder, and passes the resulting feature sequence to a two-layer Long Short-Term Memory (LSTM) network. Five-fold stratified cross-validation yields a mean AUC of 0.822 +/- 0.016 (95% CI: [0.790,0.853]), compared to 0.641 for a static EfficientNet baseline trained on the full 60-second window. Ablation studies confirm that temporal chunking and multi-channel signal fusion both contribute independently to classification performance. Per-alarm type analysis reveals that Ventricular Flutter is the most accurately classified alarm type (AUC 0.820) while Asystole remains the hardest (AUC 0.722). Error analysis identifies 65 false negatives and 85 high-confidence misclassifications as the primary failure modes. All code and results are publicly available at https://github.com/Arun-K-Ram/sigmamedstat.

  • 1 authors
·
May 27

Toward World Modeling of Physiological Signals with Chaos-Theoretic Balancing and Latent Dynamics

Physiological time series signals reflect complex, multi-scale dynamical processes of the human body. Existing modeling studies focus on static tasks such as classification, event forecasting, or short-horizon next step prediction, while long-horizon signal-level forecasting and predictive nature of physiological signals remain underexplored. We introduce NormWear-2, a world model that encodes both multivariate physiological signals and clinical intervention variables into a shared latent space and models their joint temporal evolution as a dynamical system. Our approach combines inference from prior pre-trained knowledge (intuition) with instant non-parametric latent state transition adaptation (insight), enabling coherent forecasting across multiple temporal scales, conditioned on heterogeneous clinical interventions. During the pretraining phase, we find that chaos-theoretic balancing of dynamical regime diversity yields more robust representations, with a smaller balanced corpus outperforming one twice its size and capturing bifurcation regimes. We evaluate the world model performance across diverse real-world physiological datasets spanning heterogeneous temporal resolutions and intervention regimes, covering daily life, point-of-care, and clinical settings, including fitness planning, hemodialysis, diabetes management, and surgical monitoring. These evaluation datasets comprise records from 8,026 subjects, spanning study durations from 3.2 hours for high-resolution signal data to 2.3 years for longitudinal clinical biomarker tracking. NormWear-2 achieves the best overall forecasting performance across time, frequency, and latent representation domains, with significant improvements over state-of-the-art time series foundation models, while maintaining competitive downstream representation quality, providing a step toward general-purpose world models for physiological signals.

  • 11 authors
·
May 13

BAAI Cardiac Agent: An intelligent multimodal agent for automated reasoning and diagnosis of cardiovascular diseases from cardiac magnetic resonance imaging

Cardiac magnetic resonance (CMR) is a cornerstone for diagnosing cardiovascular disease. However, it remains underutilized due to complex, time-consuming interpretation across multi-sequences, phases, quantitative measures that heavily reliant on specialized expertise. Here, we present BAAI Cardiac Agent, a multimodal intelligent system designed for end-to-end CMR interpretation. The agent integrates specialized cardiac expert models to perform automated segmentation of cardiac structures, functional quantification, tissue characterization and disease diagnosis, and generates structured clinical reports within a unified workflow. Evaluated on CMR datasets from two hospitals (2413 patients) spanning 7-types of major cardiovascular diseases, the agent achieved an area under the receiver-operating-characteristic curve exceeding 0.93 internally and 0.81 externally. In the task of estimating left ventricular function indices, the results generated by this system for core parameters such as ejection fraction, stroke volume, and left ventricular mass are highly consistent with clinical reports, with Pearson correlation coefficients all exceeding 0.90. The agent outperformed state-of-the-art models in segmentation and diagnostic tasks, and generated clinical reports showing high concordance with expert radiologists (six readers across three experience levels). By dynamically orchestrating expert models for coordinated multimodal analysis, this agent framework enables accurate, efficient CMR interpretation and highlights its potentials for complex clinical imaging workflows. Code is available at https://github.com/plantain-herb/Cardiac-Agent.

  • 21 authors
·
Apr 4

PVBM: A Python Vasculature Biomarker Toolbox Based On Retinal Blood Vessel Segmentation

Introduction: Blood vessels can be non-invasively visualized from a digital fundus image (DFI). Several studies have shown an association between cardiovascular risk and vascular features obtained from DFI. Recent advances in computer vision and image segmentation enable automatising DFI blood vessel segmentation. There is a need for a resource that can automatically compute digital vasculature biomarkers (VBM) from these segmented DFI. Methods: In this paper, we introduce a Python Vasculature BioMarker toolbox, denoted PVBM. A total of 11 VBMs were implemented. In particular, we introduce new algorithmic methods to estimate tortuosity and branching angles. Using PVBM, and as a proof of usability, we analyze geometric vascular differences between glaucomatous patients and healthy controls. Results: We built a fully automated vasculature biomarker toolbox based on DFI segmentations and provided a proof of usability to characterize the vascular changes in glaucoma. For arterioles and venules, all biomarkers were significant and lower in glaucoma patients compared to healthy controls except for tortuosity, venular singularity length and venular branching angles. Conclusion: We have automated the computation of 11 VBMs from retinal blood vessel segmentation. The PVBM toolbox is made open source under a GNU GPL 3 license and is available on physiozoo.com (following publication).

  • 6 authors
·
Jul 31, 2022

PhysDrive: A Multimodal Remote Physiological Measurement Dataset for In-vehicle Driver Monitoring

Robust and unobtrusive in-vehicle physiological monitoring is crucial for ensuring driving safety and user experience. While remote physiological measurement (RPM) offers a promising non-invasive solution, its translation to real-world driving scenarios is critically constrained by the scarcity of comprehensive datasets. Existing resources are often limited in scale, modality diversity, the breadth of biometric annotations, and the range of captured conditions, thereby omitting inherent real-world challenges in driving. Here, we present PhysDrive, the first large-scale multimodal dataset for contactless in-vehicle physiological sensing with dedicated consideration on various modality settings and driving factors. PhysDrive collects data from 48 drivers, including synchronized RGB, near-infrared camera, and raw mmWave radar data, accompanied with six synchronized ground truths (ECG, BVP, Respiration, HR, RR, and SpO2). It covers a wide spectrum of naturalistic driving conditions, including driver motions, dynamic natural light, vehicle types, and road conditions. We extensively evaluate both signal-processing and deep-learning methods on PhysDrive, establishing a comprehensive benchmark across all modalities, and release full open-source code with compatibility for mainstream public toolboxes. We envision PhysDrive will serve as a foundational resource and accelerate research on multimodal driver monitoring and smart-cockpit systems.

  • 9 authors
·
Jul 25, 2025

Large-scale Training of Foundation Models for Wearable Biosignals

Tracking biosignals is crucial for monitoring wellness and preempting the development of severe medical conditions. Today, wearable devices can conveniently record various biosignals, creating the opportunity to monitor health status without disruption to one's daily routine. Despite widespread use of wearable devices and existing digital biomarkers, the absence of curated data with annotated medical labels hinders the development of new biomarkers to measure common health conditions. In fact, medical datasets are usually small in comparison to other domains, which is an obstacle for developing neural network models for biosignals. To address this challenge, we have employed self-supervised learning using the unlabeled sensor data collected under informed consent from the large longitudinal Apple Heart and Movement Study (AHMS) to train foundation models for two common biosignals: photoplethysmography (PPG) and electrocardiogram (ECG) recorded on Apple Watch. We curated PPG and ECG datasets from AHMS that include data from ~141K participants spanning ~3 years. Our self-supervised learning framework includes participant level positive pair selection, stochastic augmentation module and a regularized contrastive loss optimized with momentum training, and generalizes well to both PPG and ECG modalities. We show that the pre-trained foundation models readily encode information regarding participants' demographics and health conditions. To the best of our knowledge, this is the first study that builds foundation models using large-scale PPG and ECG data collected via wearable consumer devices x2013 prior works have commonly used smaller-size datasets collected in clinical and experimental settings. We believe PPG and ECG foundation models can enhance future wearable devices by reducing the reliance on labeled data and hold the potential to help the users improve their health.

  • 6 authors
·
Dec 8, 2023

From Centerlines to Hemodynamics: Anisotropic RBF Decoders for Coronary Arteries

Accurate and rapid estimation of hemodynamic metrics, such as pressure and wall shear stress (WSS), is important for assessing the severity of Coronary Artery Disease (CAD). Existing approaches, including invasive Fractional Flow Reserve (FFR) measurements and computationally expensive Computational Fluid Dynamics (CFD) simulations, face challenges in invasiveness, cost, and speed. We present a framework for fast, non-invasive coronary hemodynamics prediction. The model encodes 1D vessel centerlines together with inlet flow rate using a transformer-based encoder, and predicts continuous wall-based fields via an anisotropic Radial Basis Function (RBF) decoder aligned with vessel morphology. To support training and evaluation, we introduce two datasets with paired steady-state OpenFOAM simulations: (i) a synthetic benchmark of 4,200 single-vessel geometries with controlled anatomical variations, and (ii) a multi-vessel dataset derived from ImageCAS including 4,800 cases spanning both right and left coronary arteries, generated by randomly introducing stenoses and varying physiologically plausible flow rates. Across both datasets, our method achieves lower pressure and WSS errors than strong neural-operator baselines (GNOT, Transolver, and ONO) at a fraction of the computational cost of CFD. On the multi-vessel dataset, using 1,024 anisotropic RBF centers our model reduces the mean relative L2 error by 52% compared to the best neural-operator baseline, while at 128 centers it requires 13.8x fewer FLOPs than GNOT and still outperforms all baselines. The single-vessel dataset is publicly available at https://huggingface.co/datasets/angioinsight/single-vessel-flow.

  • 3 authors
·
May 25

CanonicalPhys: Pose-Robust Remote Photoplethysmography via Canonical-Space Priors

Deep remote photoplethysmography (rPPG) attains sub-bpm heart-rate error on frontal, stationary faces yet degrades sharply under head pose: on MMPD, the state-of-the-art FactorizePhys backbone's MAE grows 1.60times from frontal (|yaw|{<}15^circ) to large-yaw (|yaw|{geq}45^circ) frames. We argue that pose is a coordinate-structural nuisance rather than a data-augmentation problem: in image coordinates the same pixel maps to different anatomy at different poses, blocking three priors otherwise natural for rPPG, namely the dichromatic reflection model, pulse-phase invariance across skin regions, and the POS/CHROM chromaticity projection, each of which presumes a stable anatomy-to-pixel mapping. We introduce CanonicalPhys, which prepends a differentiable four-point homography that fixes four facial anchors at canonical positions; in this canonical frame the three priors become expressible as a per-pixel Lambertian weight, a cross-ROI temporal consistency loss, and knowledge distillation from windowed POS, none of which adds trainable parameters over the backbone. At an identical parameter count, CanonicalPhys reduces MMPD's frontal-to-large-yaw MAE degradation from 1.60times to 1.33times and flattens the mild-yaw bin from 1.32times to 1.07times (across CanonicalPhys variants), with matched cross-dataset MAE reductions of up to 32% on pose-rich targets. Code: https://github.com/infraface/CanonicalPhys

  • 4 authors
·
Jul 16

Motion simulation of radio-labeled cells in whole-body positron emission tomography

Cell tracking is a subject of active research gathering great interest in medicine and biology. Positron emission tomography (PET) is well suited for tracking radio-labeled cells in vivo due to its exceptional sensitivity and whole-body capability. For validation, ground-truth data are desirable that realistically mimic the flow of cells in a clinical situation. This study develops a workflow (CeFloPS) for simulating moving radio-labeled cells in a human phantom. From the XCAT phantom, the blood vessels are reduced to nodal networks along which cells can move and distribute to organs and tissues. The movement is directed by the blood flow, which is calculated in each node using the Hagen-Pooiseuille equation and Kirchhoff's laws assuming laminar flow. Organs are voxelized and movement of cells from artery entry to vein exit is generated via a biased 3D random walk. The probabilities of cells moving or remaining in tissues are derived from rate constants of tracer kinetic-based compartment modeling. PET listmode data is generated using the Monte-Carlo simulation framework GATE based on the definition of a large-body PET scanner with cell paths as moving radioactive sources and the XCAT phantom providing attenuation data. From the flow simulation of 100,000 cells, 100 sample cells were further processed by GATE and listmode data was reconstructed into images for comparison. As demonstrated by comparisons of simulated and reconstructed cell distributions, CeFloPS is capable of simulating cell behavior in whole-body PET. It achieves this simulation in a way that is anatomically and physiologically reasonable, thereby providing valuable data for the development and validation of cell tracking algorithms.

  • 5 authors
·
Jul 10, 2024

Sensing Cardiac Health Across Scenarios and Devices: A Multi-Modal Foundation Model Pretrained on Heterogeneous Data from 1.7 Million Individuals

Cardiac biosignals, such as electrocardiograms (ECG) and photoplethysmograms (PPG), are of paramount importance for the diagnosis, prevention, and management of cardiovascular diseases, and have been extensively used in a variety of clinical tasks. Conventional deep learning approaches for analyzing these signals typically rely on homogeneous datasets and static bespoke models, limiting their robustness and generalizability across diverse clinical settings and acquisition protocols. In this study, we present a cardiac sensing foundation model (CSFM) that leverages advanced transformer architectures and a generative, masked pretraining strategy to learn unified representations from vast, heterogeneous health records. Our model is pretrained on an innovative multi-modal integration of data from multiple large-scale datasets (including MIMIC-III-WDB, MIMIC-IV-ECG, and CODE), comprising cardiac signals and the corresponding clinical or machine-generated text reports from approximately 1.7 million individuals. We demonstrate that the embeddings derived from our CSFM not only serve as effective feature extractors across diverse cardiac sensing scenarios, but also enable seamless transfer learning across varying input configurations and sensor modalities. Extensive evaluations across diagnostic tasks, demographic information recognition, vital sign measurement, clinical outcome prediction, and ECG question answering reveal that CSFM consistently outperforms traditional one-modal-one-task approaches. Notably, CSFM exhibits robust performance across multiple ECG lead configurations from standard 12-lead systems to single-lead setups, and in scenarios where only ECG, only PPG, or a combination thereof is available. These findings highlight the potential of CSFM as a versatile and scalable solution, for comprehensive cardiac monitoring.

  • 13 authors
·
Jun 23, 2025

Relationship between pulmonary nodule malignancy and surrounding pleurae, airways and vessels: a quantitative study using the public LIDC-IDRI dataset

To investigate whether the pleurae, airways and vessels surrounding a nodule on non-contrast computed tomography (CT) can discriminate benign and malignant pulmonary nodules. The LIDC-IDRI dataset, one of the largest publicly available CT database, was exploited for study. A total of 1556 nodules from 694 patients were involved in statistical analysis, where nodules with average scorings <3 and >3 were respectively denoted as benign and malignant. Besides, 339 nodules from 113 patients with diagnosis ground-truth were independently evaluated. Computer algorithms were developed to segment pulmonary structures and quantify the distances to pleural surface, airways and vessels, as well as the counting number and normalized volume of airways and vessels near a nodule. Odds ratio (OR) and Chi-square (\chi^2) testing were performed to demonstrate the correlation between features of surrounding structures and nodule malignancy. A non-parametric receiver operating characteristic (ROC) analysis was conducted in logistic regression to evaluate discrimination ability of each structure. For benign and malignant groups, the average distances from nodules to pleural surface, airways and vessels are respectively (6.56, 5.19), (37.08, 26.43) and (1.42, 1.07) mm. The correlation between nodules and the counting number of airways and vessels that contact or project towards nodules are respectively (OR=22.96, \chi^2=105.04) and (OR=7.06, \chi^2=290.11). The correlation between nodules and the volume of airways and vessels are (OR=9.19, \chi^2=159.02) and (OR=2.29, \chi^2=55.89). The areas-under-curves (AUCs) for pleurae, airways and vessels are respectively 0.5202, 0.6943 and 0.6529. Our results show that malignant nodules are often surrounded by more pulmonary structures compared with benign ones, suggesting that features of these structures could be viewed as lung cancer biomarkers.

  • 8 authors
·
Jun 24, 2021

Monash University, UEA, UCR Time Series Extrinsic Regression Archive

Time series research has gathered lots of interests in the last decade, especially for Time Series Classification (TSC) and Time Series Forecasting (TSF). Research in TSC has greatly benefited from the University of California Riverside and University of East Anglia (UCR/UEA) Time Series Archives. On the other hand, the advancement in Time Series Forecasting relies on time series forecasting competitions such as the Makridakis competitions, NN3 and NN5 Neural Network competitions, and a few Kaggle competitions. Each year, thousands of papers proposing new algorithms for TSC and TSF have utilized these benchmarking archives. These algorithms are designed for these specific problems, but may not be useful for tasks such as predicting the heart rate of a person using photoplethysmogram (PPG) and accelerometer data. We refer to this problem as Time Series Extrinsic Regression (TSER), where we are interested in a more general methodology of predicting a single continuous value, from univariate or multivariate time series. This prediction can be from the same time series or not directly related to the predictor time series and does not necessarily need to be a future value or depend heavily on recent values. To the best of our knowledge, research into TSER has received much less attention in the time series research community and there are no models developed for general time series extrinsic regression problems. Most models are developed for a specific problem. Therefore, we aim to motivate and support the research into TSER by introducing the first TSER benchmarking archive. This archive contains 19 datasets from different domains, with varying number of dimensions, unequal length dimensions, and missing values. In this paper, we introduce the datasets in this archive and did an initial benchmark on existing models.

  • 4 authors
·
Jun 19, 2020

Learning Tubule-Sensitive CNNs for Pulmonary Airway and Artery-Vein Segmentation in CT

Training convolutional neural networks (CNNs) for segmentation of pulmonary airway, artery, and vein is challenging due to sparse supervisory signals caused by the severe class imbalance between tubular targets and background. We present a CNNs-based method for accurate airway and artery-vein segmentation in non-contrast computed tomography. It enjoys superior sensitivity to tenuous peripheral bronchioles, arterioles, and venules. The method first uses a feature recalibration module to make the best use of features learned from the neural networks. Spatial information of features is properly integrated to retain relative priority of activated regions, which benefits the subsequent channel-wise recalibration. Then, attention distillation module is introduced to reinforce representation learning of tubular objects. Fine-grained details in high-resolution attention maps are passing down from one layer to its previous layer recursively to enrich context. Anatomy prior of lung context map and distance transform map is designed and incorporated for better artery-vein differentiation capacity. Extensive experiments demonstrated considerable performance gains brought by these components. Compared with state-of-the-art methods, our method extracted much more branches while maintaining competitive overall segmentation performance. Codes and models are available at http://www.pami.sjtu.edu.cn/News/56

  • 9 authors
·
Dec 10, 2020