new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Oct 16

From Centerlines to Hemodynamics: Anisotropic RBF Decoders for Coronary Arteries

Accurate and rapid estimation of hemodynamic metrics, such as pressure and wall shear stress (WSS), is important for assessing the severity of Coronary Artery Disease (CAD). Existing approaches, including invasive Fractional Flow Reserve (FFR) measurements and computationally expensive Computational Fluid Dynamics (CFD) simulations, face challenges in invasiveness, cost, and speed. We present a framework for fast, non-invasive coronary hemodynamics prediction. The model encodes 1D vessel centerlines together with inlet flow rate using a transformer-based encoder, and predicts continuous wall-based fields via an anisotropic Radial Basis Function (RBF) decoder aligned with vessel morphology. To support training and evaluation, we introduce two datasets with paired steady-state OpenFOAM simulations: (i) a synthetic benchmark of 4,200 single-vessel geometries with controlled anatomical variations, and (ii) a multi-vessel dataset derived from ImageCAS including 4,800 cases spanning both right and left coronary arteries, generated by randomly introducing stenoses and varying physiologically plausible flow rates. Across both datasets, our method achieves lower pressure and WSS errors than strong neural-operator baselines (GNOT, Transolver, and ONO) at a fraction of the computational cost of CFD. On the multi-vessel dataset, using 1,024 anisotropic RBF centers our model reduces the mean relative L2 error by 52% compared to the best neural-operator baseline, while at 128 centers it requires 13.8x fewer FLOPs than GNOT and still outperforms all baselines. The single-vessel dataset is publicly available at https://huggingface.co/datasets/angioinsight/single-vessel-flow.

  • 3 authors
·
May 25

LaneSegNet: Map Learning with Lane Segment Perception for Autonomous Driving

A map, as crucial information for downstream applications of an autonomous driving system, is usually represented in lanelines or centerlines. However, existing literature on map learning primarily focuses on either detecting geometry-based lanelines or perceiving topology relationships of centerlines. Both of these methods ignore the intrinsic relationship of lanelines and centerlines, that lanelines bind centerlines. While simply predicting both types of lane in one model is mutually excluded in learning objective, we advocate lane segment as a new representation that seamlessly incorporates both geometry and topology information. Thus, we introduce LaneSegNet, the first end-to-end mapping network generating lane segments to obtain a complete representation of the road structure. Our algorithm features two key modifications. One is a lane attention module to capture pivotal region details within the long-range feature space. Another is an identical initialization strategy for reference points, which enhances the learning of positional priors for lane attention. On the OpenLane-V2 dataset, LaneSegNet outperforms previous counterparts by a substantial gain across three tasks, i.e., map element detection (+4.8 mAP), centerline perception (+6.9 DET_l), and the newly defined one, lane segment perception (+5.6 mAP). Furthermore, it obtains a real-time inference speed of 14.7 FPS. Code is accessible at https://github.com/OpenDriveLab/LaneSegNet.

OpenDriveLab OpenDriveLab
·
Dec 26, 2023

CoDimRecon: Agentic Reconstruction of Sim-Ready 3D Scenes with Deformable Curves, Surfaces, and Volumes

Reconstructing simulation-ready 3D scenes from real-world observations enables robotics, gaming, and immersive applications, yet existing methods largely assume rigid objects. This leaves an important gap for deformables, whose simulation-ready geometry depends on dimensionality (curves, surfaces, or volumes) and whose behavior may require models beyond elasticity. We present CoDimRecon, an agentic framework that reconstructs editable scenes containing rigid, articulated, and deformable objects from multi-view RGB observations. Scene-level geometric priors ground scale and layout, while object-level generated meshes guide the agent toward detailed, compact geometry; articulated rigid objects are decomposed into movable parts with explicit joints. For deformables, category-wise agent sessions reconstruct curves as centerlines with radii, surfaces as manifold shells with thickness, and volumes as watertight solids for volumetric meshing. Reusable simulator skills initialize compatible physical models and parameters, while agent-guided behavioral tests expose mismatches and trigger targeted revisions of motion, geometry, numerics, or material modeling. On evaluated Replica and ScanNet++ scenes, CoDimRecon achieves competitive compositional reconstruction accuracy while additionally producing deformable assets for rod, shell, and solid simulation. We further demonstrate robot interactions across all three representations, including a controlled paper-folding case in which behavioral testing motivates plastic bending.

  • 5 authors
·
Sep 29

Hybrid Context Forests and Bilateral Viterbi Matching for 3D Rib Centerline Tracing in CT

Automatic extraction and anatomical numbering (R01-R12, L01-L12) of all 24 rib centerlines in thoracic CT is essential for unfolded rib visualization, fracture detection, and surgical navigation, but remains challenging due to adjacent-bone confluence, calcified costal cartilage bridges, kyphotic pose variation, and partial visibility of terminal ribs. We present ribline, an open-source three-stage framework combining: (1) an automatically detected lung-apex and vertebral-midline coordinate frame with a kyphosis-aware azimuthal angle for point ordering along each rib; (2) a hybrid voxel detector fusing an anatomically anchored Semantic Context Forest (SCF) with a lightweight 3D U-Net; and (3) a global stage that decomposes the probability skeleton into candidate curves, assigns rib indices via a bilateral Viterbi dynamic program coupled across both hemithoraces, and refines curves via template recovery and normal-plane centering (RibSnake). On the Siemens Corporate Research 2 mm thoracic CT benchmark (47 training and 12 evaluation scans), our pipeline achieves a labeled Chamfer distance of 2.05 mm, labeled clDice of 0.886 (3 mm) and 0.945 (4 mm), 97.2% labeling accuracy (278/286 ribs), and zero false-positive curves on the evaluation split, and 3.64 mm (median 2.39 mm) with 91.8% labeling accuracy across all 59 annotated scans (1,402 ribs) in 5-fold cross-validation. Code: https://github.com/wq2012/ribline Pretrained Models: https://huggingface.co/collections/wq2012/ribline

  • 1 authors
·
Oct 11