new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Aug 12

Relationship between pulmonary nodule malignancy and surrounding pleurae, airways and vessels: a quantitative study using the public LIDC-IDRI dataset

To investigate whether the pleurae, airways and vessels surrounding a nodule on non-contrast computed tomography (CT) can discriminate benign and malignant pulmonary nodules. The LIDC-IDRI dataset, one of the largest publicly available CT database, was exploited for study. A total of 1556 nodules from 694 patients were involved in statistical analysis, where nodules with average scorings <3 and >3 were respectively denoted as benign and malignant. Besides, 339 nodules from 113 patients with diagnosis ground-truth were independently evaluated. Computer algorithms were developed to segment pulmonary structures and quantify the distances to pleural surface, airways and vessels, as well as the counting number and normalized volume of airways and vessels near a nodule. Odds ratio (OR) and Chi-square (\chi^2) testing were performed to demonstrate the correlation between features of surrounding structures and nodule malignancy. A non-parametric receiver operating characteristic (ROC) analysis was conducted in logistic regression to evaluate discrimination ability of each structure. For benign and malignant groups, the average distances from nodules to pleural surface, airways and vessels are respectively (6.56, 5.19), (37.08, 26.43) and (1.42, 1.07) mm. The correlation between nodules and the counting number of airways and vessels that contact or project towards nodules are respectively (OR=22.96, \chi^2=105.04) and (OR=7.06, \chi^2=290.11). The correlation between nodules and the volume of airways and vessels are (OR=9.19, \chi^2=159.02) and (OR=2.29, \chi^2=55.89). The areas-under-curves (AUCs) for pleurae, airways and vessels are respectively 0.5202, 0.6943 and 0.6529. Our results show that malignant nodules are often surrounded by more pulmonary structures compared with benign ones, suggesting that features of these structures could be viewed as lung cancer biomarkers.

  • 8 authors
·
Jun 24, 2021

How much of an LLM-generated clinical corpus is actually new? A production-scale measurement of content redundancy for provenance classification

Clinical machine learning increasingly relies on training corpora generated by large language models (LLMs) rather than annotated by clinicians, and such corpora are described and reused largely on the basis of their reported scale. We test whether volume reflects information content. Analysing the complete output of a multi-agent clinical extraction pipeline applied to 167,034 patient narratives, 2.51 billion generated tokens across the ten text-bearing channels of an eleven-channel pipeline, we introduce Provenance-based Redundancy Decomposition, a token-level classification of the entire output by source. Only 10.9% of the output is trainable-unique content while 79.4% is redundant; raw token count overstates information content by roughly ninefold. The redundancy arises through two distinct mechanisms, verbatim copying of source context into per-item fields, and duplication of generated text across records, of which only the former is losslessly removable. An independent, model-free analysis based on lossless compression confirms the redundancy, recovering the two mechanisms without reference to the provenance labels. One pipeline channel carries almost no redundancy, showing that the level of redundancy depends on how each channel is structured rather than being a fixed property of LLM extraction. Because uncorrected redundancy up-weights the longer, more complex presentations that generate the most items, it skews the token-level training distribution of the corpus, a property we measure directly. In a controlled downstream test, de-duplicating the corpus before adaptation improved a clinical encoder on external disease-recognition benchmarks at equal token budget, robustly across adaptation depths and replicated on a second benchmark, confirming that the redundancy carries a measurable cost beyond storage. The classification tool is released openly.

  • 2 authors
·
Jun 27

VoCo: A Simple-yet-Effective Volume Contrastive Learning Framework for 3D Medical Image Analysis

Self-Supervised Learning (SSL) has demonstrated promising results in 3D medical image analysis. However, the lack of high-level semantics in pre-training still heavily hinders the performance of downstream tasks. We observe that 3D medical images contain relatively consistent contextual position information, i.e., consistent geometric relations between different organs, which leads to a potential way for us to learn consistent semantic representations in pre-training. In this paper, we propose a simple-yet-effective Volume Contrast (VoCo) framework to leverage the contextual position priors for pre-training. Specifically, we first generate a group of base crops from different regions while enforcing feature discrepancy among them, where we employ them as class assignments of different regions. Then, we randomly crop sub-volumes and predict them belonging to which class (located at which region) by contrasting their similarity to different base crops, which can be seen as predicting contextual positions of different sub-volumes. Through this pretext task, VoCo implicitly encodes the contextual position priors into model representations without the guidance of annotations, enabling us to effectively improve the performance of downstream tasks that require high-level semantics. Extensive experimental results on six downstream tasks demonstrate the superior effectiveness of VoCo. Code will be available at https://github.com/Luffy03/VoCo.

  • 3 authors
·
Feb 27, 2024