new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Oct 22

DeepCORO-CLIP: A Multi-View Foundation Model for Comprehensive Coronary Angiography Video-Text Analysis and External Validation

Coronary angiography is the reference standard for evaluating coronary artery disease, yet visual interpretation remains variable between readers. Existing artificial intelligence methods typically analyze single frames or projections and focus mainly on stenosis, limiting comprehensive coronary assessment. We present DeepCORO-CLIP, a multi-view foundation model trained with video-text contrastive learning on 203,808 angiography videos from 28,117 patients across 32,473 studies at the Montreal Heart Institute and externally validated on 4,249 studies from the University of California, San Francisco. DeepCORO-CLIP integrates multiple projections with attention-based pooling for study-level assessment across diagnostic, prognostic, and disease progression tasks. For significant stenosis detection, the model achieved an AUROC of 0.888 internally and 0.89 on external validation. Mean absolute error against core laboratory quantitative coronary angiography was 13.6%, lower than clinical reports at 19.0%. The model also performed strongly for chronic total occlusion, intracoronary thrombus, and coronary calcification detection. Transfer learning enabled prediction of one-year major adverse cardiovascular events with AUROC 0.79 and estimation of left ventricular ejection fraction with mean absolute error 7.3%. Embeddings also captured disease progression across serial examinations. With a mean inference time of 4.2 seconds in hospital deployment, DeepCORO-CLIP provides a foundation for automated coronary angiography interpretation at the point of care. Code, sample data, model weights, and deployment infrastructure are publicly released.

  • 9 authors
·
Mar 17

A Deep Learning Model for Coronary Artery Segmentation and Quantitative Stenosis Detection in Angiographic Images

Coronary artery disease (CAD) is a leading cause of cardiovascular-related mortality, and accurate stenosis detection is crucial for effective clinical decision-making. Coronary angiography remains the gold standard for diagnosing CAD, but manual analysis of angiograms is prone to errors and subjectivity. This study aims to develop a deep learning-based approach for the automatic segmentation of coronary arteries from angiographic images and the quantitative detection of stenosis, thereby improving the accuracy and efficiency of CAD diagnosis. We propose a novel deep learning-based method for the automatic segmentation of coronary arteries in angiographic images, coupled with a dynamic cohort method for stenosis detection. The segmentation model combines the MedSAM and VM-UNet architectures to achieve high-performance results. After segmentation, the vascular centerline is extracted, vessel diameter is computed, and the degree of stenosis is measured with high precision, enabling accurate identification of arterial stenosis. On the mixed dataset (including the ARCADE, DCA1, and GH datasets), the model achieved an average IoU of 0.6308, with sensitivity and specificity of 0.9772 and 0.9903, respectively. On the ARCADE dataset, the average IoU was 0.6303, with sensitivity of 0.9832 and specificity of 0.9933. Additionally, the stenosis detection algorithm achieved a true positive rate (TPR) of 0.5867 and a positive predictive value (PPV) of 0.5911, demonstrating the effectiveness of our model in analyzing coronary angiography images. SAM-VMNet offers a promising tool for the automated segmentation and detection of coronary artery stenosis. The model's high accuracy and robustness provide significant clinical value for the early diagnosis and treatment planning of CAD. The code and examples are available at https://github.com/qimingfan10/SAM-VMNet.

  • 6 authors
·
Jun 1, 2024

CADICA: a new dataset for coronary artery disease detection by using invasive coronary angiography

Coronary artery disease (CAD) remains the leading cause of death globally and invasive coronary angiography (ICA) is considered the gold standard of anatomical imaging evaluation when CAD is suspected. However, risk evaluation based on ICA has several limitations, such as visual assessment of stenosis severity, which has significant interobserver variability. This motivates to development of a lesion classification system that can support specialists in their clinical procedures. Although deep learning classification methods are well-developed in other areas of medical imaging, ICA image classification is still at an early stage. One of the most important reasons is the lack of available and high-quality open-access datasets. In this paper, we reported a new annotated ICA images dataset, CADICA, to provide the research community with a comprehensive and rigorous dataset of coronary angiography consisting of a set of acquired patient videos and associated disease-related metadata. This dataset can be used by clinicians to train their skills in angiographic assessment of CAD severity and by computer scientists to create computer-aided diagnostic systems to help in such assessment. In addition, baseline classification methods are proposed and analyzed, validating the functionality of CADICA and giving the scientific community a starting point to improve CAD detection.

  • 7 authors
·
Feb 1, 2024

CM-UNet: A Self-Supervised Learning-Based Model for Coronary Artery Segmentation in X-Ray Angiography

Accurate segmentation of coronary arteries remains a significant challenge in clinical practice, hindering the ability to effectively diagnose and manage coronary artery disease. The lack of large, annotated datasets for model training exacerbates this issue, limiting the development of automated tools that could assist radiologists. To address this, we introduce CM-UNet, which leverages self-supervised pre-training on unannotated datasets and transfer learning on limited annotated data, enabling accurate disease detection while minimizing the need for extensive manual annotations. Fine-tuning CM-UNet with only 18 annotated images instead of 500 resulted in a 15.2% decrease in Dice score, compared to a 46.5% drop in baseline models without pre-training. This demonstrates that self-supervised learning can enhance segmentation performance and reduce dependence on large datasets. This is one of the first studies to highlight the importance of self-supervised learning in improving coronary artery segmentation from X-ray angiography, with potential implications for advancing diagnostic accuracy in clinical practice. By enhancing segmentation accuracy in X-ray angiography images, the proposed approach aims to improve clinical workflows, reduce radiologists' workload, and accelerate disease detection, ultimately contributing to better patient outcomes. The source code is publicly available at https://github.com/CamilleChallier/Contrastive-Masked-UNet.

  • 11 authors
·
Jul 22, 2025

Segmentation and Vascular Vectorization for Coronary Artery by Geometry-based Cascaded Neural Network

Segmentation of the coronary artery is an important task for the quantitative analysis of coronary computed tomography angiography (CCTA) images and is being stimulated by the field of deep learning. However, the complex structures with tiny and narrow branches of the coronary artery bring it a great challenge. Coupled with the medical image limitations of low resolution and poor contrast, fragmentations of segmented vessels frequently occur in the prediction. Therefore, a geometry-based cascaded segmentation method is proposed for the coronary artery, which has the following innovations: 1) Integrating geometric deformation networks, we design a cascaded network for segmenting the coronary artery and vectorizing results. The generated meshes of the coronary artery are continuous and accurate for twisted and sophisticated coronary artery structures, without fragmentations. 2) Different from mesh annotations generated by the traditional marching cube method from voxel-based labels, a finer vectorized mesh of the coronary artery is reconstructed with the regularized morphology. The novel mesh annotation benefits the geometry-based segmentation network, avoiding bifurcation adhesion and point cloud dispersion in intricate branches. 3) A dataset named CCA-200 is collected, consisting of 200 CCTA images with coronary artery disease. The ground truths of 200 cases are coronary internal diameter annotations by professional radiologists. Extensive experiments verify our method on our collected dataset CCA-200 and public ASOCA dataset, with a Dice of 0.778 on CCA-200 and 0.895 on ASOCA, showing superior results. Especially, our geometry-based model generates an accurate, intact and smooth coronary artery, devoid of any fragmentations of segmented vessels.

  • 6 authors
·
May 7, 2023

Heart Disease Detection using Vision-Based Transformer Models from ECG Images

Heart disease, also known as cardiovascular disease, is a prevalent and critical medical condition characterized by the impairment of the heart and blood vessels, leading to various complications such as coronary artery disease, heart failure, and myocardial infarction. The timely and accurate detection of heart disease is of paramount importance in clinical practice. Early identification of individuals at risk enables proactive interventions, preventive measures, and personalized treatment strategies to mitigate the progression of the disease and reduce adverse outcomes. In recent years, the field of heart disease detection has witnessed notable advancements due to the integration of sophisticated technologies and computational approaches. These include machine learning algorithms, data mining techniques, and predictive modeling frameworks that leverage vast amounts of clinical and physiological data to improve diagnostic accuracy and risk stratification. In this work, we propose to detect heart disease from ECG images using cutting-edge technologies, namely vision transformer models. These models are Google-Vit, Microsoft-Beit, and Swin-Tiny. To the best of our knowledge, this is the initial endeavor concentrating on the detection of heart diseases through image-based ECG data by employing cuttingedge technologies namely, transformer models. To demonstrate the contribution of the proposed framework, the performance of vision transformer models are compared with state-of-the-art studies. Experiment results show that the proposed framework exhibits remarkable classification results.

  • 4 authors
·
Oct 19, 2023

CARDEA: Auditable Reasoning Grounded in Spatial Evidence for End-to-End Coronary Angiography Interpretation

Invasive coronary angiography (CAG) is the gold standard for diagnosing coronary artery disease, but interpretation varies substantially among observers. Existing AI systems can improve consistency but lack auditable decision processes and are limited in comprehensive open-ended assessment, undermining clinician trust and clinical adoption readiness. We developed CARDEA, a unified large vision-language model that serves as the inference core of a CAG pipeline. It was trained solely on public datasets and closed-ended tasks in three stages: visual feature alignment, a self-distilled Chain-of-Box (CoB) cold start, and reinforcement learning with verifiable rewards (RLVR) with a CoB reward encouraging bounding-box use in the reasoning trace. We assessed its two study-level diagnoses, dominance classification and complexity assessment, against a dedicated classifier and two interventional cardiologists. Report generation was excluded from training and evaluated zero-shot across stages on an external cohort using vessel-severity macro-F_1. CARDEA trailed the classifier on in-distribution dominance but drew level under domain shift (accuracy, 0.91 [95% confidence interval (CI), 0.86 to 0.95]) and was comparable to the cardiologists on complexity assessment (accuracy, 0.90 [CI, 0.82 to 0.97]). Only RLVR improved zero-shot report generation, raising its vessel-severity macro-F_1 (0.686 [CI, 0.664 to 0.707]) above the untuned base model (0.513) and over twice the always-normal floor (0.312). CARDEA runs an end-to-end CAG pipeline from raw multi-view videos through keyframe selection to study-level diagnosis while exposing auditable spatial evidence behind its conclusions. RLVR on verifiable closed-ended tasks surfaced open-ended reporting ability that supervised imitation did not. Clinical use requires prospective validation against expert cardiologists.

  • 5 authors
·
Sep 6 2

PPGFlowECG: Latent Rectified Flow with Cross-Modal Encoding for PPG-Guided ECG Generation and Cardiovascular Disease Detection

In clinical practice, electrocardiography (ECG) remains the gold standard for cardiac monitoring, providing crucial insights for diagnosing a wide range of cardiovascular diseases (CVDs). However, its reliance on specialized equipment and trained personnel limits feasibility for continuous routine monitoring. Photoplethysmography (PPG) offers accessible, continuous monitoring but lacks definitive electrophysiological information, preventing conclusive diagnosis. Generative models present a promising approach to translate PPG into clinically valuable ECG signals, yet current methods face substantial challenges, including the misalignment of physiological semantics in generative models and the complexity of modeling in high-dimensional signals. To this end, we propose PPGFlowECG, a two-stage framework that aligns PPG and ECG in a shared latent space via the CardioAlign Encoder and employs latent rectified flow to generate ECGs with high fidelity and interpretability. To the best of our knowledge, this is the first study to experiment on MCMED, a newly released clinical-grade dataset comprising over 10 million paired PPG-ECG samples from more than 118,000 emergency department visits with expert-labeled cardiovascular disease annotations. Results demonstrate the effectiveness of our method for PPG-to-ECG translation and cardiovascular disease detection. Moreover, cardiologist-led evaluations confirm that the synthesized ECGs achieve high fidelity and improve diagnostic reliability, underscoring our method's potential for real-world cardiovascular screening.

  • 9 authors
·
Sep 24, 2025

3D Reconstruction of Coronary Vessel Trees from Biplanar X-Ray Images Using a Geometric Approach

X-ray angiography is widely used in cardiac interventions to visualize coronary vessels, assess integrity, detect stenoses and guide treatment. We propose a framework for reconstructing 3D vessel trees from biplanar X-ray images which are extracted from two X-ray videos captured at different C-arm angles. The proposed framework consists of three main components: image segmentation, motion phase matching, and 3D reconstruction. An automatic video segmentation method for X-ray angiography to enable semantic segmentation for image segmentation and motion phase matching. The goal of the motion phase matching is to identify a pair of X-ray images that correspond to a similar respiratory and cardiac motion phase to reduce errors in 3D reconstruction. This is achieved by tracking a stationary object such as a catheter or lead within the X-ray video. The semantic segmentation approach assigns different labels to different object classes enabling accurate differentiation between blood vessels, balloons, and catheters. Once a suitable image pair is selected, key anatomical landmarks (vessel branching points and endpoints) are matched between the two views using a heuristic method that minimizes reconstruction errors. This is followed by a novel geometric reconstruction algorithm to generate the 3D vessel tree. The algorithm computes the 3D vessel centrelines by determining the intersection of two 3D surfaces. Compared to traditional methods based on epipolar constraints, the proposed approach simplifies there construction workflow and improves overall accuracy. We trained and validated our segmentation method on 62 X-ray angiography video sequences. On the test set, our method achieved a segmentation accuracy of 0.703. The 3D reconstruction framework was validated by measuring the reconstruction error of key anatomical landmarks, achieving a reprojection errors of 0.62mm +/- 0.38mm.

  • 4 authors
·
Sep 15, 2025

ECGLight: Compute-Light Framework For Paper ECG Digitization and Myocardial Infarction Screening

Electrocardiography (ECG) is one of the most widely used tests for diagnosing cardiovascular disease. Yet several remote clinics still utilize paper ECG printouts for their analysis due to limited connectivity and computational capacity. As a result, vast numbers of physical ECGs obtained in remote areas still remain incapable of being accessed by contemporary artificial-intelligence (AI)-based decision support as they require high computational resources or strong high-speed internet connectivity. This causes several cases where conditions like acute coronary occlusion (ACS) is overlooked and reperfusion therapy delayed. Although prior work has tackled digitization and diagnosis separately, and utilized advanced AI models for them, there still remains a lack of a compute-light, on-device framework that reconstructs paper ECGs at high fidelity, while accurately supporting multiple clinically relevant endpoints. We address this need with an end-to-end lightweight on-device digitization-to-diagnosis pipeline that converts a smartphone photo or scan of a paper ECG into a calibrated 12-lead signal and screens for Myocardial Infarction (MI) pathologies, with SHapley Additive exPlanations (SHAP) to support interpretability. Trained and evaluated on 21,799 ECGs from the PTB-XL dataset and further validated on hospital-acquired ECG-Matrix dataset, the complete system runs in <30 s per ECG on CPU-only resources, achieving 95.51% accuracy (F1 = 0.9519) for MI detection on PTB-XL and 88.89% accuracy (F1 = 0.8862) for OMI detection on ECG-Matrix. This work showcases that legacy paper records can be reliably democratized in any part of the world, providing a scalable decision support when digital ECG export, connectivity, or high-end compute are unavailable

  • 6 authors
·
Jul 7

Computer Aided Detection for Pulmonary Embolism Challenge (CAD-PE)

Rationale: Computer aided detection (CAD) algorithms for Pulmonary Embolism (PE) algorithms have been shown to increase radiologists' sensitivity with a small increase in specificity. However, CAD for PE has not been adopted into clinical practice, likely because of the high number of false positives current CAD software produces. Objective: To generate a database of annotated computed tomography pulmonary angiographies, use it to compare the sensitivity and false positive rate of current algorithms and to develop new methods that improve such metrics. Methods: 91 Computed tomography pulmonary angiography scans were annotated by at least one radiologist by segmenting all pulmonary emboli visible on the study. 20 annotated CTPAs were open to the public in the form of a medical image analysis challenge. 20 more were kept for evaluation purposes. 51 were made available post-challenge. 8 submissions, 6 of them novel, were evaluated on the 20 evaluation CTPAs. Performance was measured as per embolus sensitivity vs. false positives per scan curve. Results: The best algorithms achieved a per-embolus sensitivity of 75% at 2 false positives per scan (fps) or of 70% at 1 fps, outperforming the state of the art. Deep learning approaches outperformed traditional machine learning ones, and their performance improved with the number of training cases. Significance: Through this work and challenge we have improved the state-of-the art of computer aided detection algorithms for pulmonary embolism. An open database and an evaluation benchmark for such algorithms have been generated, easing the development of further improvements. Implications on clinical practice will need further research.

  • 20 authors
·
Mar 30, 2020

Latent Interpolation Learning Using Diffusion Models for Cardiac Volume Reconstruction

Cardiac Magnetic Resonance (CMR) imaging is a critical tool for diagnosing and managing cardiovascular disease, yet its utility is often limited by the sparse acquisition of 2D short-axis slices, resulting in incomplete volumetric information. Accurate 3D reconstruction from these sparse slices is essential for comprehensive cardiac assessment, but existing methods face challenges, including reliance on predefined interpolation schemes (e.g., linear or spherical), computational inefficiency, and dependence on additional semantic inputs such as segmentation labels or motion data. To address these limitations, we propose a novel Cardiac Latent Interpolation Diffusion (CaLID) framework that introduces three key innovations. First, we present a data-driven interpolation scheme based on diffusion models, which can capture complex, non-linear relationships between sparse slices and improves reconstruction accuracy. Second, we design a computationally efficient method that operates in the latent space and speeds up 3D whole-heart upsampling time by a factor of 24, reducing computational overhead compared to previous methods. Third, with only sparse 2D CMR images as input, our method achieves SOTA performance against baseline methods, eliminating the need for auxiliary input such as morphological guidance, thus simplifying workflows. We further extend our method to 2D+T data, enabling the effective modeling of spatiotemporal dynamics and ensuring temporal coherence. Extensive volumetric evaluations and downstream segmentation tasks demonstrate that CaLID achieves superior reconstruction quality and efficiency. By addressing the fundamental limitations of existing approaches, our framework advances the state of the art for spatio and spatiotemporal whole-heart reconstruction, offering a robust and clinically practical solution for cardiovascular imaging.

  • 11 authors
·
Aug 19, 2025

Artificial Intelligence-derived Vascular Age from Photoplethysmography: A Novel Digital Biomarker for Cardiovascular Health

With the increasing availability of wearable devices, photoplethysmography (PPG) has emerged as a promising non-invasive tool for monitoring human hemodynamics. We propose a deep learning framework to estimate vascular age (AI-vascular age) from PPG signals, incorporating a distribution-aware loss to address biases caused by imbalanced data. The model was developed using data from the UK Biobank (UKB), with 98,672 participants in the development cohort and 113,559 participants (144,683 data pairs) for clinical evaluation. After adjusting for key confounders, individuals with a vascular age gap (AI-vascular age minus calendar age) exceeding 9 years had a significantly higher risk of major adverse cardiovascular and cerebrovascular events (MACCE) (HR = 2.37, p < 0.005) and secondary outcomes, including diabetes (HR = 2.69, p < 0.005), hypertension (HR = 2.88, p < 0.005), coronary heart disease (HR = 2.20, p < 0.005), heart failure (HR = 2.15, p < 0.005), myocardial infarction (HR = 2.51, p < 0.005), stroke (HR = 2.55, p < 0.005), and all-cause mortality (HR = 2.51, p < 0.005). Conversely, participants with a vascular age gap below -9 years exhibited a significantly lower incidence of these outcomes. We further evaluated the longitudinal applicability of AI-vascular age using serial PPG data from the UKB, demonstrating its value in risk stratification by leveraging AI-vascular age at two distinct time points to predict future MACCE incidence. External validation was performed on a MIMIC-III-derived cohort (n = 2,343), where each one-year increase in vascular age gap was significantly associated with elevated in-hospital mortality risk (OR = 1.02, p < 0.005). In conclusion, our study establishes AI-vascular age as a novel, non-invasive digital biomarker for cardiovascular health assessment.

  • 5 authors
·
Feb 18, 2025

Microscale stress-geometry interactions in an additively manufactured NiTi cardiovascular stent: A synchrotron dual imaging tomography and diffraction study

This study explores cardiovascular stents fabricated using laser powder bed fusion (LPBF); an emerging method to offer patient-specific customisable parts. Here, the shape memory alloy NiTi, in a near equiatomic composition, was investigated to deconvolve the material response from macroscopic component effects. Specifically, stress-geometry interactions were revealed, in-situ, for a minaturised cardiovascular stent subjected to an externally applied cylindrical stress whilst acquiring synchrotron X-ray imaging and diffraction data. The approach enabled the collection of spatially resolved micromechanical deformation data; the formation of stress-induced martensite and R-phase was evident, occurring in locations near junctions between stent ligaments where stress concentrations exist. In the as-fabricated condition, hardness maps were obtained through nanoindentation, demonstrating that the localised deformation and deformation patterning is further controlled by porosity and microstructural heterogeneity. Electron backscatter diffraction (EBSD) supported these observations, showing a finer grain structure near stent junctions with higher associated lattice curvature. These features, combined with stress concentrations when loaded will initiate localised phase transformations. If the stent was subjected to repeated loading, representing in-vivo conditions, these regions would be susceptible to cyclic damage through transformation memory loss, leading to premature component failure. This study highlights the challenges that must be addressed for the post-processing treatment of LABF-processed stents for healthcare-related applications.

  • 11 authors
·
Dec 12, 2023

DS6, Deformation-aware Semi-supervised Learning: Application to Small Vessel Segmentation with Noisy Training Data

Blood vessels of the brain provide the human brain with the required nutrients and oxygen. As a vulnerable part of the cerebral blood supply, pathology of small vessels can cause serious problems such as Cerebral Small Vessel Diseases (CSVD). It has also been shown that CSVD is related to neurodegeneration, such as Alzheimer's disease. With the advancement of 7 Tesla MRI systems, higher spatial image resolution can be achieved, enabling the depiction of very small vessels in the brain. Non-Deep Learning-based approaches for vessel segmentation, e.g., Frangi's vessel enhancement with subsequent thresholding, are capable of segmenting medium to large vessels but often fail to segment small vessels. The sensitivity of these methods to small vessels can be increased by extensive parameter tuning or by manual corrections, albeit making them time-consuming, laborious, and not feasible for larger datasets. This paper proposes a deep learning architecture to automatically segment small vessels in 7 Tesla 3D Time-of-Flight (ToF) Magnetic Resonance Angiography (MRA) data. The algorithm was trained and evaluated on a small imperfect semi-automatically segmented dataset of only 11 subjects; using six for training, two for validation, and three for testing. The deep learning model based on U-Net Multi-Scale Supervision was trained using the training subset and was made equivariant to elastic deformations in a self-supervised manner using deformation-aware learning to improve the generalisation performance. The proposed technique was evaluated quantitatively and qualitatively against the test set and achieved a Dice score of 80.44 pm 0.83. Furthermore, the result of the proposed method was compared against a selected manually segmented region (62.07 resultant Dice) and has shown a considerable improvement (18.98\%) with deformation-aware learning.

  • 10 authors
·
Jun 18, 2020

Assessing Coronary Microvascular Dysfunction using Angiography-based Data-driven Methods

Coronary microvascular dysfunction (CMD), characterized by impaired regulation of blood flow in the coronary microcirculation, plays a key role in the pathogenesis of ischemic heart disease and is increasingly recognized as a contributor to adverse cardiovascular outcomes. Despite its clinical importance, CMD remains underdiagnosed due to the reliance on invasive procedures such as pressure wire-based measurements of the index of microcirculatory resistance (IMR) and coronary flow reserve (CFR), which are costly, time-consuming, and carry procedural risks. To date, no study has sought to quantify CMD indices using data-driven approaches while leveraging the rich information contained in coronary angiograms. To address these limitations, this study proposes a novel data-driven framework for inference of CMD indices based on coronary angiography. A physiologically validated multi-physics model was used to generate synthetic datasets for data-driven model training, consisting of CMD indices and computational angiograms with corresponding contrast intensity profiles (CIPs). Two neural network architectures were developed: a single-input-channel encoder-MLP model for IMR prediction and a dual-input-channel encoder-MLP model for CFR prediction, both incorporating epistemic uncertainty estimation to quantify prediction confidence. Results demonstrate that the data-driven models achieve high predictive accuracy when evaluated against physics-based synthetic datasets, and that the uncertainty estimates are positively correlated with prediction errors. Furthermore, the utility of CIPs as informative surrogates for coronary physiology is demonstrated, underscoring the potential of the proposed framework to enable accurate, real-time, image-based CMD assessment using routine angiography without the need for more invasive approaches.

  • 5 authors
·
Dec 23, 2025

BS-Diff: Effective Bone Suppression Using Conditional Diffusion Models from Chest X-Ray Images

Chest X-rays (CXRs) are commonly utilized as a low-dose modality for lung screening. Nonetheless, the efficacy of CXRs is somewhat impeded, given that approximately 75% of the lung area overlaps with bone, which in turn hampers the detection and diagnosis of diseases. As a remedial measure, bone suppression techniques have been introduced. The current dual-energy subtraction imaging technique in the clinic requires costly equipment and subjects being exposed to high radiation. To circumvent these issues, deep learning-based image generation algorithms have been proposed. However, existing methods fall short in terms of producing high-quality images and capturing texture details, particularly with pulmonary vessels. To address these issues, this paper proposes a new bone suppression framework, termed BS-Diff, that comprises a conditional diffusion model equipped with a U-Net architecture and a simple enhancement module to incorporate an autoencoder. Our proposed network cannot only generate soft tissue images with a high bone suppression rate but also possesses the capability to capture fine image details. Additionally, we compiled the largest dataset since 2010, including data from 120 patients with high-definition, high-resolution paired CXRs and soft tissue images collected by our affiliated hospital. Extensive experiments, comparative analyses, ablation studies, and clinical evaluations indicate that the proposed BS-Diff outperforms several bone-suppression models across multiple metrics. Our code can be accessed at https://github.com/Benny0323/BS-Diff.

  • 11 authors
·
Nov 26, 2023

Self-Supervised U-Net for Segmenting Flat and Sessile Polyps

Colorectal Cancer(CRC) poses a great risk to public health. It is the third most common cause of cancer in the US. Development of colorectal polyps is one of the earliest signs of cancer. Early detection and resection of polyps can greatly increase survival rate to 90%. Manual inspection can cause misdetections because polyps vary in color, shape, size and appearance. To this end, Computer-Aided Diagnosis systems(CADx) has been proposed that detect polyps by processing the colonoscopic videos. The system acts a secondary check to help clinicians reduce misdetections so that polyps may be resected before they transform to cancer. Polyps vary in color, shape, size, texture and appearance. As a result, the miss rate of polyps is between 6% and 27% despite the prominence of CADx solutions. Furthermore, sessile and flat polyps which have diameter less than 10 mm are more likely to be undetected. Convolutional Neural Networks(CNN) have shown promising results in polyp segmentation. However, all of these works have a supervised approach and are limited by the size of the dataset. It was observed that smaller datasets reduce the segmentation accuracy of ResUNet++. We train a U-Net to inpaint randomly dropped out pixels in the image as a proxy task. The dataset we use for pre-training is Kvasir-SEG dataset. This is followed by a supervised training on the limited Kvasir-Sessile dataset. Our experimental results demonstrate that with limited annotated dataset and a larger unlabeled dataset, self-supervised approach is a better alternative than fully supervised approach. Specifically, our self-supervised U-Net performs better than five segmentation models which were trained in supervised manner on the Kvasir-Sessile dataset.

  • 4 authors
·
Oct 17, 2021

Cardiac-CLIP: A Vision-Language Foundation Model for 3D Cardiac CT Images

Foundation models have demonstrated remarkable potential in medical domain. However, their application to complex cardiovascular diagnostics remains underexplored. In this paper, we present Cardiac-CLIP, a multi-modal foundation model designed for 3D cardiac CT images. Cardiac-CLIP is developed through a two-stage pre-training strategy. The first stage employs a 3D masked autoencoder (MAE) to perform self-supervised representation learning from large-scale unlabeled volumetric data, enabling the visual encoder to capture rich anatomical and contextual features. In the second stage, contrastive learning is introduced to align visual and textual representations, facilitating cross-modal understanding. To support the pre-training, we collect 16641 real clinical CT scans, supplemented by 114k publicly available data. Meanwhile, we standardize free-text radiology reports into unified templates and construct the pathology vectors according to diagnostic attributes, based on which the soft-label matrix is generated to supervise the contrastive learning process. On the other hand, to comprehensively evaluate the effectiveness of Cardiac-CLIP, we collect 6,722 real-clinical data from 12 independent institutions, along with the open-source data to construct the evaluation dataset. Specifically, Cardiac-CLIP is comprehensively evaluated across multiple tasks, including cardiovascular abnormality classification, information retrieval and clinical analysis. Experimental results demonstrate that Cardiac-CLIP achieves state-of-the-art performance across various downstream tasks in both internal and external data. Particularly, Cardiac-CLIP exhibits great effectiveness in supporting complex clinical tasks such as the prospective prediction of acute coronary syndrome, which is notoriously difficult in real-world scenarios.

  • 23 authors
·
Jul 29, 2025