new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Nov 4

UniTele: Learning Device-Conditioned Degradations for Unified Smartphone Telephoto Super-Resolution

Super-telephoto imaging on mobile phones suffers from complex, device-dependent degradations that are poorly captured by conventional handcrafted pipelines. Collecting large-scale aligned training pairs across different phones and diverse scenes, however, is both costly and difficult to scale. We therefore study whether device-specific degradations can be learned from only a small number of physical captures and transferred for training a unified super-resolution (SR) model. Our key idea is to factor degradation learning into two learnable components: one captures the device-specific imaging characteristics under well-resolved conditions, while the other captures the additional information loss and artifacts that arise in super-telephoto imaging. We build a paired benchmark across three phone brands (Huawei, Apple, and vivo) by photographing the same content at two display sizes and zoom settings. The larger displayed image is captured at the phone's maximum optical zoom setting, while the smaller image is photographed directly at the phone's highest native zoom setting through the phone's native imaging pipeline. The benchmark contains 519 training and 60 held-out pairs. We use the benchmark to learn device-specific degradation, then apply it to external images to synthesize thousands of additional pairs to train our UniTele SR model. Relative to the pretrained Qwen and FLUX backbones before adaptation, the full UniTele training recipe substantially improves paired restoration fidelity and perceptual similarity on the held-out benchmark and yields markedly more stable and visually faithful restorations.

  • 8 authors
·
Oct 29

pyMEAL: A Multi-Encoder Augmentation-Aware Learning for Robust and Generalizable Medical Image Translation

Medical imaging is critical for diagnostics, but clinical adoption of advanced AI-driven imaging faces challenges due to patient variability, image artifacts, and limited model generalization. While deep learning has transformed image analysis, 3D medical imaging still suffers from data scarcity and inconsistencies due to acquisition protocols, scanner differences, and patient motion. Traditional augmentation uses a single pipeline for all transformations, disregarding the unique traits of each augmentation and struggling with large data volumes. To address these challenges, we propose a Multi-encoder Augmentation-Aware Learning (MEAL) framework that leverages four distinct augmentation variants processed through dedicated encoders. Three fusion strategies such as concatenation (CC), fusion layer (FL), and adaptive controller block (BD) are integrated to build multi-encoder models that combine augmentation-specific features before decoding. MEAL-BD uniquely preserves augmentation-aware representations, enabling robust, protocol-invariant feature learning. As demonstrated in a Computed Tomography (CT)-to-T1-weighted Magnetic Resonance Imaging (MRI) translation study, MEAL-BD consistently achieved the best performance on both unseen- and predefined-test data. On both geometric transformations (like rotations and flips) and non-augmented inputs, MEAL-BD outperformed other competing methods, achieving higher mean peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM) scores. These results establish MEAL as a reliable framework for preserving structural fidelity and generalizing across clinically relevant variability. By reframing augmentation as a source of diverse, generalizable features, MEAL supports robust, protocol-invariant learning, advancing clinically reliable medical imaging solutions.

  • 6 authors
·
May 30, 2025

Brain-ID: Learning Contrast-agnostic Anatomical Representations for Brain Imaging

Recent learning-based approaches have made astonishing advances in calibrated medical imaging like computerized tomography (CT), yet they struggle to generalize in uncalibrated modalities -- notably magnetic resonance (MR) imaging, where performance is highly sensitive to the differences in MR contrast, resolution, and orientation. This prevents broad applicability to diverse real-world clinical protocols. We introduce Brain-ID, an anatomical representation learning model for brain imaging. With the proposed "mild-to-severe" intra-subject generation, Brain-ID is robust to the subject-specific brain anatomy regardless of the appearance of acquired images (e.g., contrast, deformation, resolution, artifacts). Trained entirely on synthetic data, Brain-ID readily adapts to various downstream tasks through only one layer. We present new metrics to validate the intra- and inter-subject robustness of Brain-ID features, and evaluate their performance on four downstream applications, covering contrast-independent (anatomy reconstruction/contrast synthesis, brain segmentation), and contrast-dependent (super-resolution, bias field estimation) tasks. Extensive experiments on six public datasets demonstrate that Brain-ID achieves state-of-the-art performance in all tasks on different MRI modalities and CT, and more importantly, preserves its performance on low-resolution and small datasets. Code is available at https://github.com/peirong26/Brain-ID.

  • 5 authors
·
Nov 28, 2023

M3Ret: Unleashing Zero-shot Multimodal Medical Image Retrieval via Self-Supervision

Medical image retrieval is essential for clinical decision-making and translational research, relying on discriminative visual representations. Yet, current methods remain fragmented, relying on separate architectures and training strategies for 2D, 3D, and video-based medical data. This modality-specific design hampers scalability and inhibits the development of unified representations. To enable unified learning, we curate a large-scale hybrid-modality dataset comprising 867,653 medical imaging samples, including 2D X-rays and ultrasounds, RGB endoscopy videos, and 3D CT scans. Leveraging this dataset, we train M3Ret, a unified visual encoder without any modality-specific customization. It successfully learns transferable representations using both generative (MAE) and contrastive (SimDINO) self-supervised learning (SSL) paradigms. Our approach sets a new state-of-the-art in zero-shot image-to-image retrieval across all individual modalities, surpassing strong baselines such as DINOv3 and the text-supervised BMC-CLIP. More remarkably, strong cross-modal alignment emerges without paired data, and the model generalizes to unseen MRI tasks, despite never observing MRI during pretraining, demonstrating the generalizability of purely visual self-supervision to unseen modalities. Comprehensive analyses further validate the scalability of our framework across model and data sizes. These findings deliver a promising signal to the medical imaging community, positioning M3Ret as a step toward foundation models for visual SSL in multimodal medical image understanding.

  • 8 authors
·
Sep 1, 2025 1

MInDI-3D: Iterative Deep Learning in 3D for Sparse-view Cone Beam Computed Tomography

We present MInDI-3D (Medical Inversion by Direct Iteration in 3D), the first 3D conditional diffusion-based model for real-world sparse-view Cone Beam Computed Tomography (CBCT) artefact removal, aiming to reduce imaging radiation exposure. A key contribution is extending the "InDI" concept from 2D to a full 3D volumetric approach for medical images, implementing an iterative denoising process that refines the CBCT volume directly from sparse-view input. A further contribution is the generation of a large pseudo-CBCT dataset (16,182) from chest CT volumes of the CT-RATE public dataset to robustly train MInDI-3D. We performed a comprehensive evaluation, including quantitative metrics, scalability analysis, generalisation tests, and a clinical assessment by 11 clinicians. Our results show MInDI-3D's effectiveness, achieving a 12.96 (6.10) dB PSNR gain over uncorrected scans with only 50 projections on the CT-RATE pseudo-CBCT (independent real-world) test set and enabling an 8x reduction in imaging radiation exposure. We demonstrate its scalability by showing that performance improves with more training data. Importantly, MInDI-3D matches the performance of a 3D U-Net on real-world scans from 16 cancer patients across distortion and task-based metrics. It also generalises to new CBCT scanner geometries. Clinicians rated our model as sufficient for patient positioning across all anatomical sites and found it preserved lung tumour boundaries well.

  • 10 authors
·
Aug 13, 2025

A Comprehensive Study of GPT-4V's Multimodal Capabilities in Medical Imaging

This paper presents a comprehensive evaluation of GPT-4V's capabilities across diverse medical imaging tasks, including Radiology Report Generation, Medical Visual Question Answering (VQA), and Visual Grounding. While prior efforts have explored GPT-4V's performance in medical image analysis, to the best of our knowledge, our study represents the first quantitative evaluation on publicly available benchmarks. Our findings highlight GPT-4V's potential in generating descriptive reports for chest X-ray images, particularly when guided by well-structured prompts. Meanwhile, its performance on the MIMIC-CXR dataset benchmark reveals areas for improvement in certain evaluation metrics, such as CIDEr. In the domain of Medical VQA, GPT-4V demonstrates proficiency in distinguishing between question types but falls short of the VQA-RAD benchmark in terms of accuracy. Furthermore, our analysis finds the limitations of conventional evaluation metrics like the BLEU scores, advocating for the development of more semantically robust assessment methods. In the field of Visual Grounding, GPT-4V exhibits preliminary promise in recognizing bounding boxes, but its precision is lacking, especially in identifying specific medical organs and signs. Our evaluation underscores the significant potential of GPT-4V in the medical imaging domain, while also emphasizing the need for targeted refinements to fully unlock its capabilities.

  • 10 authors
·
Oct 31, 2023

Imaging foundation model for universal enhancement of non-ideal measurement CT

Non-ideal measurement computed tomography (NICT), which sacrifices optimal imaging standards for new advantages in CT imaging, is expanding the clinical application scope of CT images. However, with the reduction of imaging standards, the image quality has also been reduced, extremely limiting the clinical acceptability. Although numerous studies have demonstrated the feasibility of deep learning for the NICT enhancement in specific scenarios, their high data cost and limited generalizability have become large obstacles. The recent research on the foundation model has brought new opportunities for building a universal NICT enhancement model - bridging the image quality degradation with minimal data cost. However, owing to the challenges in the collection of large pre-training datasets and the compatibility of data variation, no success has been reported. In this paper, we propose a multi-scale integrated Transformer AMPlifier (TAMP), the first imaging foundation model for universal NICT enhancement. It has been pre-trained on a large-scale physical-driven simulation dataset with 3.6 million NICT-ICT image pairs, and is able to directly generalize to the NICT enhancement tasks with various non-ideal settings and body regions. Via the adaptation with few data, it can further achieve professional performance in real-world specific scenarios. Our extensive experiments have demonstrated that the proposed TAMP has significant potential for promoting the exploration and application of NICT and serving a wider range of medical scenarios.

  • 7 authors
·
Oct 2, 2024

Prostate-Specific Foundation Models for Enhanced Detection of Clinically Significant Cancer

Accurate prostate cancer diagnosis remains challenging. Even when using MRI, radiologists exhibit low specificity and significant inter-observer variability, leading to potential delays or inaccuracies in identifying clinically significant cancers. This leads to numerous unnecessary biopsies and risks of missing clinically significant cancers. Here we present prostate vision contrastive network (ProViCNet), prostate organ-specific vision foundation models for Magnetic Resonance Imaging (MRI) and Trans-Rectal Ultrasound imaging (TRUS) for comprehensive cancer detection. ProViCNet was trained and validated using 4,401 patients across six institutions, as a prostate cancer detection model on radiology images relying on patch-level contrastive learning guided by biopsy confirmed radiologist annotations. ProViCNet demonstrated consistent performance across multiple internal and external validation cohorts with area under the receiver operating curve values ranging from 0.875 to 0.966, significantly outperforming radiologists in the reader study (0.907 versus 0.805, p<0.001) for mpMRI, while achieving 0.670 to 0.740 for TRUS. We also integrated ProViCNet with standard PSA to develop a virtual screening test, and we showed that we can maintain the high sensitivity for detecting clinically significant cancers while more than doubling specificity from 15% to 38% (p<0.001), thereby substantially reducing unnecessary biopsies. These findings highlight that ProViCNet's potential for enhancing prostate cancer diagnosis accuracy and reduce unnecessary biopsies, thereby optimizing diagnostic pathways.

  • 17 authors
·
Feb 1, 2025

Decipher-MR: A Vision-Language Foundation Model for 3D MRI Representations

Magnetic Resonance Imaging (MRI) is a critical medical imaging modality in clinical diagnosis and research, yet its complexity and heterogeneity pose challenges for automated analysis, particularly in scalable and generalizable machine learning applications. While foundation models have revolutionized natural language and vision tasks, their application to MRI remains limited due to data scarcity and narrow anatomical focus. In this work, we present Decipher-MR, a 3D MRI-specific vision-language foundation model trained on a large-scale dataset comprising 200,000 MRI series from over 22,000 studies spanning diverse anatomical regions, sequences, and pathologies. Decipher-MR integrates self-supervised vision learning with report-guided text supervision to build robust, generalizable representations, enabling effective adaptation across broad applications. To enable robust and diverse clinical tasks with minimal computational overhead, Decipher-MR supports a modular design that enables tuning of lightweight, task-specific decoders attached to a frozen pretrained encoder. Following this setting, we evaluate Decipher-MR across diverse benchmarks including disease classification, demographic prediction, anatomical localization, and cross-modal retrieval, demonstrating consistent performance gains over existing foundation models and task-specific approaches. Our results establish Decipher-MR as a scalable and versatile foundation for MRI-based AI, facilitating efficient development across clinical and research domains.

  • 14 authors
·
Sep 25, 2025

FluoroSAM: A Language-promptable Foundation Model for Flexible X-ray Image Segmentation

Language promptable X-ray image segmentation would enable greater flexibility for human-in-the-loop workflows in diagnostic and interventional precision medicine. Prior efforts have contributed task-specific models capable of solving problems within a narrow scope, but expanding to broader use requires additional data, annotations, and training time. Recently, language-aligned foundation models (LFMs) -- machine learning models trained on large amounts of highly variable image and text data thus enabling broad applicability -- have emerged as promising tools for automated image analysis. Existing foundation models for medical image analysis focus on scenarios and modalities where large, richly annotated datasets are available. However, the X-ray imaging modality features highly variable image appearance and applications, from diagnostic chest X-rays to interventional fluoroscopy, with varying availability of data. To pave the way toward an LFM for comprehensive and language-aligned analysis of arbitrary medical X-ray images, we introduce FluoroSAM, a language-promptable variant of the Segment Anything Model, trained from scratch on 3M synthetic X-ray images from a wide variety of human anatomies, imaging geometries, and viewing angles. These include pseudo-ground truth masks for 128 organ types and 464 tools with associated text descriptions. FluoroSAM is capable of segmenting myriad anatomical structures and tools based on natural language prompts, thanks to the novel incorporation of vector quantization (VQ) of text embeddings in the training process. We demonstrate FluoroSAM's performance quantitatively on real X-ray images and showcase on several applications how FluoroSAM is a key enabler for rich human-machine interaction in the X-ray image acquisition and analysis context. Code is available at https://github.com/arcadelab/fluorosam.

  • 8 authors
·
Mar 12, 2024

Experimental Design for Multi-Channel Imaging via Task-Driven Feature Selection

This paper presents a data-driven, task-specific paradigm for experimental design, to shorten acquisition time, reduce costs, and accelerate the deployment of imaging devices. Current approaches in experimental design focus on model-parameter estimation and require specification of a particular model, whereas in imaging, other tasks may drive the design. Furthermore, such approaches often lead to intractable optimization problems in real-world imaging applications. Here we present a new paradigm for experimental design that simultaneously optimizes the design (set of image channels) and trains a machine-learning model to execute a user-specified image-analysis task. The approach obtains data densely-sampled over the measurement space (many image channels) for a small number of acquisitions, then identifies a subset of channels of prespecified size that best supports the task. We propose a method: TADRED for TAsk-DRiven Experimental Design in imaging, to identify the most informative channel-subset whilst simultaneously training a network to execute the task given the subset. Experiments demonstrate the potential of TADRED in diverse imaging applications: several clinically-relevant tasks in magnetic resonance imaging; and remote sensing and physiological applications of hyperspectral imaging. Results show substantial improvement over classical experimental design, two recent application-specific methods within the new paradigm, and state-of-the-art approaches in supervised feature selection. We anticipate further applications of our approach. Code is available: https://github.com/sbb-gh/experimental-design-multichannel

  • 3 authors
·
Oct 13, 2022

Prototype-Enhanced Multi-View Learning for Thyroid Nodule Ultrasound Classification

Thyroid nodule classification using ultrasound imaging is essential for early diagnosis and clinical decision-making; however, despite promising performance on in-distribution data, existing deep learning methods often exhibit limited robustness and generalisation when deployed across different ultrasound devices or clinical environments. This limitation is mainly attributed to the pronounced heterogeneity of thyroid ultrasound images, which can lead models to capture spurious correlations rather than reliable diagnostic cues. To address this challenge, we propose PEMV-thyroid, a Prototype-Enhanced Multi-View learning framework that accounts for data heterogeneity by learning complementary representations from multiple feature perspectives and refining decision boundaries through a prototype-based correction mechanism with mixed prototype information. By integrating multi-view representations with prototype-level guidance, the proposed approach enables more stable representation learning under heterogeneous imaging conditions. Extensive experiments on multiple thyroid ultrasound datasets demonstrate that PEMV-thyroid consistently outperforms state-of-the-art methods, particularly in cross-device and cross-domain evaluation scenarios, leading to improved diagnostic accuracy and generalisation performance in real-world clinical settings. The source code is available at https://github.com/chenyangmeii/Prototype-Enhanced-Multi-View-Learning.

  • 7 authors
·
Mar 29

PhyMRI-SR: Toward Physics-Aware MRI Image Super-Resolution

Magnetic resonance imaging (MRI) super-resolution is vital for improving diagnostic accessibility, yet most methods treat it as a deterministic mapping from a fixed low-resolution input to a high-resolution target. This overlooks a key property of MRI acquisition physics: spatial resolution and signal-to-noise ratio (SNR) are inherently coupled, making any given low-resolution scan merely one of many possible realizations under varying acquisition trade-offs. We rethink MRI super-resolution as a physics-aware reconstruction problem, in which the goal is to identify the optimal resolution-SNR configuration and then super-resolve it to obtain high-quality MRI results. A key implication of this formulation is that MRI resolution becomes dynamic rather than fixed. To handle such resolution-heterogeneous inputs, we adapt 2D Gaussian Splatting (2D GS) to MRI by formulating reconstruction as a coordinate-based, resolution-agnostic rendering problem. To further enhance fidelity, we introduce three innovations: (1) a prior-aware Gaussian representation that combines an Anatomical Structure Prior for tissue-specific kernel initialization with an Imaging System Prior that captures hardware characteristics via a covariance dictionary; (2) a physics-constrained signal modeling scheme that predicts intrinsic tissue parameters (proton density rho and effective relaxation rate R2) and synthesizes intensities through governing physical equations, ensuring biophysically plausible contrast; and (3) a meta-learning framework that alleviates paired-data scarcity by pretraining on simulated data and adapting to real-world conditions. Extensive experiments on dynamic-resolution datasets and standard benchmarks demonstrate that our method achieves state-of-the-art performance, highlighting its strong potential for clinical deployment.

Metal artefact reduction sequences for a piezoelectric bone conduction implant using a realistic head phantom in MRI

Industry standards require medical device manufacturers to perform implant-induced artefact testing in phantoms at a pre-clinical stage to define the extent of artefacts that can be expected during MRI. Once a device is commercially available, studies on volunteers, cadavers or patients are performed to investigate implant-induced artefacts and artefact reduction methods more in-depth. This study describes the design and evaluation of a realistic head phantom for pre-clinical implant-induced artefact testing in a relevant environment. A case study is performed where a state-of-the-art piezoelectric bone conduction implant is used in the 1.5 T and 3 T MRI environments. Images were acquired using clinical and novel metal artefact reducing (MARS) sequences at both field strengths. Artefact width and length were measured in a healthy volunteer and compared with artefact sizes obtained in the phantom. Artefact sizes are reported that are similar in shape between the phantom and a volunteer, yet with dimensions differing up to 20% between both. When the implant magnet is removed, the artefact size can be reduced below a diameter of 5 cm, whilst the presence of an implant magnet and splint creates higher artefacts up to 20 cm in diameter. Pulse sequences have been altered to reduce the scan time up to 7 minutes, while preserving the image quality. These results show that the anthropomorphic phantom can be used at a preclinical stage to provide clinically relevant images, illustrating the impact of the artefact on important brain structures.

  • 5 authors
·
Jun 6, 2023

A 3D Cross-modal Keypoint Descriptor for MR-US Matching and Registration

Intraoperative registration of real-time ultrasound (iUS) to preoperative Magnetic Resonance Imaging (MRI) remains an unsolved problem due to severe modality-specific differences in appearance, resolution, and field-of-view. To address this, we propose a novel 3D cross-modal keypoint descriptor for MRI-iUS matching and registration. Our approach employs a patient-specific matching-by-synthesis approach, generating synthetic iUS volumes from preoperative MRI. This enables supervised contrastive training to learn a shared descriptor space. A probabilistic keypoint detection strategy is then employed to identify anatomically salient and modality-consistent locations. During training, a curriculum-based triplet loss with dynamic hard negative mining is used to learn descriptors that are i) robust to iUS artifacts such as speckle noise and limited coverage, and ii) rotation-invariant. At inference, the method detects keypoints in MR and real iUS images and identifies sparse matches, which are then used to perform rigid registration. Our approach is evaluated using 3D MRI-iUS pairs from the ReMIND dataset. Experiments show that our approach outperforms state-of-the-art keypoint matching methods across 11 patients, with an average precision of 69.8%. For image registration, our method achieves a competitive mean Target Registration Error of 2.39 mm on the ReMIND2Reg benchmark. Compared to existing iUS-MR registration approaches, our framework is interpretable, requires no manual initialization, and shows robustness to iUS field-of-view variation. Code, data and model weights are available at https://github.com/morozovdd/CrossKEY.

  • 3 authors
·
Mar 31

MedGSSR: Generalizable Medical Image Super-Resolution 3D Reconstruction via Hierarchical Feed-forward Gaussian Splatting

High-resolution volumetric medical imaging is critical for clinical diagnosis, yet acquisition is often limited by scanner hardware, scan time, and for CT, radiation dose. Medical 3D Super-Resolution (Med3DSR) offers a computational alternative, but existing methods commonly rely on per-subject optimization, pretrained priors, or coordinate-based implicit representations, which compromise anatomical fidelity and limit efficiency. To address these limitations, we present MedGSSR, a fully end-to-end feed-forward framework that represents volumes as an explicit 3D Gaussian field for Med3DSR. Unlike coordinate-based implicit functions, our explicit 3D Gaussian representation naturally enhances signal continuity and local high-frequency fidelity. Specifically, MedGSSR explicitly decouples the reconstruction process into coarse-grained structural preservation and fine-grained textural refinement through the proposed Pyramid Anatomical Encoder and a Hierarchical Gaussian Projector. To support arbitrary-scale super-resolution, we introduce sub-voxel Gaussian decomposition and a Differentiable Gaussian Voxelizer that directly queries the continuous 3D intensity field, reducing discretization artifacts. Extensive experiments on MRI and CT benchmarks demonstrate that MedGSSR significantly outperforms state-of-the-art methods. Notably, our framework exhibits robust generalizability across unseen datasets without requiring per-subject optimization, enabling fast inference and high-fidelity volumetric super-resolution in practical clinical settings. Our project webpage, including code, is at https://william2ai.github.io/medgssr

  • 10 authors
·
Sep 5

The Role of AI in Early Detection of Life-Threatening Diseases: A Retinal Imaging Perspective

Retinal imaging has emerged as a powerful, non-invasive modality for detecting and quantifying biomarkers of systemic diseases-ranging from diabetes and hypertension to Alzheimer's disease and cardiovascular disorders but current insights remain dispersed across platforms and specialties. Recent technological advances in optical coherence tomography (OCT/OCTA) and adaptive optics (AO) now deliver ultra-high-resolution scans (down to 5 {\mu}m ) with superior contrast and spatial integration, allowing early identification of microvascular abnormalities and neurodegenerative changes. At the same time, AI-driven and machine learning (ML) algorithms have revolutionized the analysis of large-scale retinal datasets, increasing sensitivity and specificity; for example, deep learning models achieve > 90 \% sensitivity for diabetic retinopathy and AUC = 0.89 for the prediction of cardiovascular risk from fundus photographs. The proliferation of mobile health technologies and telemedicine platforms further extends access, reduces costs, and facilitates community-based screening and longitudinal monitoring. Despite these breakthroughs, translation into routine practice is hindered by heterogeneous imaging protocols, limited external validation of AI models, and integration challenges within clinical workflows. In this review, we systematically synthesize the latest OCT/OCT and AO developments, AI/ML approaches, and mHealth/Tele-ophthalmology initiatives and quantify their diagnostic performance across disease domains. Finally, we propose a roadmap for multicenter protocol standardization, prospective validation trials, and seamless incorporation of retinal screening into primary and specialty care pathways-paving the way for precision prevention, early intervention, and ongoing treatment of life-threatening systemic diseases.

  • 3 authors
·
May 27, 2025

Contrastive learning of global and local features for medical image segmentation with limited annotations

A key requirement for the success of supervised deep learning is a large labeled dataset - a condition that is difficult to meet in medical image analysis. Self-supervised learning (SSL) can help in this regard by providing a strategy to pre-train a neural network with unlabeled data, followed by fine-tuning for a downstream task with limited annotations. Contrastive learning, a particular variant of SSL, is a powerful technique for learning image-level representations. In this work, we propose strategies for extending the contrastive learning framework for segmentation of volumetric medical images in the semi-supervised setting with limited annotations, by leveraging domain-specific and problem-specific cues. Specifically, we propose (1) novel contrasting strategies that leverage structural similarity across volumetric medical images (domain-specific cue) and (2) a local version of the contrastive loss to learn distinctive representations of local regions that are useful for per-pixel segmentation (problem-specific cue). We carry out an extensive evaluation on three Magnetic Resonance Imaging (MRI) datasets. In the limited annotation setting, the proposed method yields substantial improvements compared to other self-supervision and semi-supervised learning techniques. When combined with a simple data augmentation technique, the proposed method reaches within 8% of benchmark performance using only two labeled MRI volumes for training, corresponding to only 4% (for ACDC) of the training data used to train the benchmark. The code is made public at https://github.com/krishnabits001/domain_specific_cl.

  • 4 authors
·
Jun 18, 2020

LIBAD: A Multimodal Anomaly Detection Benchmark for Li-Ion Battery Electrode Manufacturing

Multimodal industrial anomaly detection has largely focused on discrete products using strongly correlated RGB and 3D observations, leaving continuous process manufacturing and weakly correlated sensing modalities underexplored. We introduce LIBAD, the first multimodal anomaly detection benchmark for Li-ion battery electrode manufacturing. Collected from real roll-to-roll production lines, LIBAD provides aligned double-sided visible-light imaging, high-resolution X-ray radiography, and inline-compatible low-resolution X-ray radiography. Electrode patches in LIBAD exhibit highly homogeneous material appearance, while defect evidence can be strong in one modality but weak or absent in another, resulting in pronounced cross-modal anomaly inconsistency. Benchmarks of representative methods under the inline-compatible visible-light and low-resolution X-ray setting exhibit limited transferability and consistently high false-positive rates. We therefore propose DA-Core, a memory-based method that jointly considers feature-space coverage and local density of normal features during coreset selection, allowing compact memory banks to better preserve fine-grained normal variations. With a coreset ratio of 0.05, DA-Core reduces FPR95 from 60.4% to 54.3% compared with standard farthest point sampling. At this ratio, DA-Core also outperforms the best standard coreset result (obtained at 0.20) while reducing inference time by 43.9%. These results suggest that both the data distribution of normal features and the modality relationship itself require explicit consideration when designing anomaly detection methods for process manufacturing.

  • 4 authors
·
Aug 7

Enabling Ultra-Fast Cardiovascular Imaging Across Heterogeneous Clinical Environments with a Generalist Foundation Model and Multimodal Database

Multimodal cardiovascular magnetic resonance (CMR) imaging provides comprehensive and non-invasive insights into cardiovascular disease (CVD) diagnosis and underlying mechanisms. Despite decades of advancements, its widespread clinical adoption remains constrained by prolonged scan times and heterogeneity across medical environments. This underscores the urgent need for a generalist reconstruction foundation model for ultra-fast CMR imaging, one capable of adapting across diverse imaging scenarios and serving as the essential substrate for all downstream analyses. To enable this goal, we curate MMCMR-427K, the largest and most comprehensive multimodal CMR k-space database to date, comprising 427,465 multi-coil k-space data paired with structured metadata across 13 international centers, 12 CMR modalities, 15 scanners, and 17 CVD categories in populations across three continents. Building on this unprecedented resource, we introduce CardioMM, a generalist reconstruction foundation model capable of dynamically adapting to heterogeneous fast CMR imaging scenarios. CardioMM unifies semantic contextual understanding with physics-informed data consistency to deliver robust reconstructions across varied scanners, protocols, and patient presentations. Comprehensive evaluations demonstrate that CardioMM achieves state-of-the-art performance in the internal centers and exhibits strong zero-shot generalization to unseen external settings. Even at imaging acceleration up to 24x, CardioMM reliably preserves key cardiac phenotypes, quantitative myocardial biomarkers, and diagnostic image quality, enabling a substantial increase in CMR examination throughput without compromising clinical integrity. Together, our open-access MMCMR-427K database and CardioMM framework establish a scalable pathway toward high-throughput, high-quality, and clinically accessible cardiovascular imaging.

  • 64 authors
·
Dec 25, 2025

MedImageInsight: An Open-Source Embedding Model for General Domain Medical Imaging

In this work, we present MedImageInsight, an open-source medical imaging embedding model. MedImageInsight is trained on medical images with associated text and labels across a diverse collection of domains, including X-Ray, CT, MRI, dermoscopy, OCT, fundus photography, ultrasound, histopathology, and mammography. Rigorous evaluations demonstrate MedImageInsight's ability to achieve state-of-the-art (SOTA) or human expert level performance across classification, image-image search, and fine-tuning tasks. Specifically, on public datasets, MedImageInsight achieves SOTA in CT 3D medical image retrieval, as well as SOTA in disease classification and search for chest X-ray, dermatology, and OCT imaging. Furthermore, MedImageInsight achieves human expert performance in bone age estimation (on both public and partner data), as well as AUC above 0.9 in most other domains. When paired with a text decoder, MedImageInsight achieves near SOTA level single image report findings generation with less than 10\% the parameters of other models. Compared to fine-tuning GPT-4o with only MIMIC-CXR data for the same task, MedImageInsight outperforms in clinical metrics, but underperforms on lexical metrics where GPT-4o sets a new SOTA. Importantly for regulatory purposes, MedImageInsight can generate ROC curves, adjust sensitivity and specificity based on clinical need, and provide evidence-based decision support through image-image search (which can also enable retrieval augmented generation). In an independent clinical evaluation of image-image search in chest X-ray, MedImageInsight outperformed every other publicly available foundation model evaluated by large margins (over 6 points AUC), and significantly outperformed other models in terms of AI fairness (across age and gender). We hope releasing MedImageInsight will help enhance collective progress in medical imaging AI research and development.

  • 31 authors
·
Oct 9, 2024

Using a 4-megapixel hybrid photon counting detector for fast, lab-based nanoscale x-ray tomography

Hybrid photon counting detectors (HPCDs) have unlocked new capabilities for x-ray-based measurements at synchrotrons around the world in the last 30 years. By leveraging independently optimized sensor and readout layers, they offer high quantum efficiency (> 80 %), ultra-low dark counts, sub-pixel point-spread function, and high count rates (> 10^{6} counts per pixel per second). Furthermore, their small pixel size and large active area endow them with excellent coverage and resolution for both real-space and reciprocal space imaging. Here, we demonstrate that HPCDs are also well-suited for laboratory-based nanoscale x-ray tomography (nano-xCT). We perform nano-xCT on an integrated circuit fabricated at the 130-nm node and produce a 3D reconstruction with 40 times more photons collected 20 times faster than in this group's previous work, for an overall speedup of 800times. We review the technical considerations of using an HPCD for tabletop tomography. We quantify our reconstruction image quality using well-established metrics, including the modulation transfer function (MTF), Fourier shell correlation (FSC), and contrast-to-noise (CNR), to validate our choice of experimental parameters that provide sufficient resolution and imaging speed. Using these metrics, we determine that even under current experimental conditions, 160 nm wiring features are reconstructed at 75-80 nm spatial resolution.

  • 11 authors
·
Feb 10

SDUM: A Scalable Deep Unrolled Model for Universal MRI Reconstruction

Clinical MRI encompasses diverse imaging protocols--spanning anatomical targets (cardiac, brain, knee), contrasts (T1, T2, mapping), sampling patterns (Cartesian, radial, spiral, kt-space), and acceleration factors--yet current deep learning reconstructions are typically protocol-specific, hindering generalization and deployment. We introduce Scalable Deep Unrolled Model (SDUM), a universal framework combining a Restormer-based reconstructor, a learned coil sensitivity map estimator (CSME), sampling-aware weighted data consistency (SWDC), universal conditioning (UC) on cascade index and protocol metadata, and progressive cascade expansion training. SDUM exhibits foundation-model-like scaling behavior: reconstruction quality follows PSNR {sim} log(parameters) with correlation r{=}0.986 (R^2{=}0.973) up to 18 cascades, demonstrating predictable performance gains with model depth. A single SDUM trained on heterogeneous data achieves state-of-the-art results across all four CMRxRecon2025 challenge tracks--multi-center, multi-disease, 5T, and pediatric--without task-specific fine-tuning, surpassing specialized baselines by up to {+}1.0~dB. On CMRxRecon2024, SDUM outperforms the winning method PromptMR+ by {+}0.55~dB; on fastMRI brain, it exceeds PC-RNN by {+}1.8~dB. Ablations validate each component: SWDC {+}0.43~dB over standard DC, per-cascade CSME {+}0.51~dB, UC {+}0.38~dB. These results establish SDUM as a practical path toward universal, scalable MRI reconstruction.

  • 6 authors
·
Dec 18, 2025

OrganLens: Organ-Specific Representation Learning for CT Foundation Models

A CT examination captures multiple organs, but many biomedical questions concern abnormalities, prognosis, or longitudinal change in a specific organ. These questions require a separate representation for each organ within the same CT volume. Existing CT foundation models commonly produce a single volume-level representation, while recent anatomy-aware methods either encode pre-separated organ volumes or explicitly disentangle images into organ token groups. The former may remove clinically relevant surrounding context, while the latter does not condition a shared encoder on a selected organ before its features are formed. We introduce OrganLens for organ-specific representation learning through self-supervision. An organ identity conditions a shared CT encoder, while organ-specific distillation and anatomy-mask supervision shape features for anatomy-weighted pooling into organ-specific representations. At inference, the shared model produces 11 organ-specific representations without external segmentation masks. We evaluate OrganLens on CT-RATE, RAD-ChestCT, INSPECT, and NLST across diverse acquisitions and downstream evaluations. Relative to CT-pretrained DINOv2, heart representations raise CT-RATE cardiomegaly AUROC from 0.910 to 0.953, while lung representations improve the Harrell C-index for NLST lung-cancer mortality by 14.2\%. The global representation reaches INSPECT Recall@10 of 33.09\% and 32.04\% for text-to-image and image-to-text retrieval, respectively. Across organ-related tasks, anatomically matched representations provide stronger task-relevant signal, while the global representation retains broad utility. OrganLens offers a scalable approach to organ-specific CT representation learning with a shared encoder. More broadly, it provides the medical research community with a reusable framework for studying organ-specific disease across cohorts and clinical endpoints.

  • 5 authors
·
Jul 27

CuNeRF: Cube-Based Neural Radiance Field for Zero-Shot Medical Image Arbitrary-Scale Super Resolution

Medical image arbitrary-scale super-resolution (MIASSR) has recently gained widespread attention, aiming to super sample medical volumes at arbitrary scales via a single model. However, existing MIASSR methods face two major limitations: (i) reliance on high-resolution (HR) volumes and (ii) limited generalization ability, which restricts their application in various scenarios. To overcome these limitations, we propose Cube-based Neural Radiance Field (CuNeRF), a zero-shot MIASSR framework that can yield medical images at arbitrary scales and viewpoints in a continuous domain. Unlike existing MIASSR methods that fit the mapping between low-resolution (LR) and HR volumes, CuNeRF focuses on building a coordinate-intensity continuous representation from LR volumes without the need for HR references. This is achieved by the proposed differentiable modules: including cube-based sampling, isotropic volume rendering, and cube-based hierarchical rendering. Through extensive experiments on magnetic resource imaging (MRI) and computed tomography (CT) modalities, we demonstrate that CuNeRF outperforms state-of-the-art MIASSR methods. CuNeRF yields better visual verisimilitude and reduces aliasing artifacts at various upsampling factors. Moreover, our CuNeRF does not need any LR-HR training pairs, which is more flexible and easier to be used than others. Our code will be publicly available soon.

  • 4 authors
·
Mar 28, 2023

Towards a clinically accessible radiology foundation model: open-access and lightweight, with automated evaluation

The scaling laws and extraordinary performance of large foundation models motivate the development and utilization of such models in biomedicine. However, despite early promising results on some biomedical benchmarks, there are still major challenges that need to be addressed before these models can be used in real-world clinics. Frontier general-domain models such as GPT-4V still have significant performance gaps in multimodal biomedical applications. More importantly, less-acknowledged pragmatic issues, including accessibility, model cost, and tedious manual evaluation make it hard for clinicians to use state-of-the-art large models directly on private patient data. Here, we explore training open-source small multimodal models (SMMs) to bridge competency gaps for unmet clinical needs in radiology. To maximize data efficiency, we adopt a modular approach by incorporating state-of-the-art pre-trained models for image and text modalities, and focusing on training a lightweight adapter to ground each modality to the text embedding space, as exemplified by LLaVA-Med. For training, we assemble a large dataset of over 697 thousand radiology image-text pairs. For evaluation, we propose CheXprompt, a GPT-4-based metric for factuality evaluation, and demonstrate its parity with expert evaluation. For best practice, we conduct a systematic ablation study on various choices in data engineering and multimodal training. The resulting LlaVA-Rad (7B) model attains state-of-the-art results on standard radiology tasks such as report generation and cross-modal retrieval, even outperforming much larger models such as GPT-4V and Med-PaLM M (84B). The inference of LlaVA-Rad is fast and can be performed on a single V100 GPU in private settings, offering a promising state-of-the-art tool for real-world clinical applications.

  • 27 authors
·
Mar 12, 2024

MRI Super-Resolution with Deep Learning: A Comprehensive Survey

High-resolution (HR) magnetic resonance imaging (MRI) is crucial for many clinical and research applications. However, achieving it remains costly and constrained by technical trade-offs and experimental limitations. Super-resolution (SR) presents a promising computational approach to overcome these challenges by generating HR images from more affordable low-resolution (LR) scans, potentially improving diagnostic accuracy and efficiency without requiring additional hardware. This survey reviews recent advances in MRI SR techniques, with a focus on deep learning (DL) approaches. It examines DL-based MRI SR methods from the perspectives of computer vision, computational imaging, inverse problems, and MR physics, covering theoretical foundations, architectural designs, learning strategies, benchmark datasets, and performance metrics. We propose a systematic taxonomy to categorize these methods and present an in-depth study of both established and emerging SR techniques applicable to MRI, considering unique challenges in clinical and research contexts. We also highlight open challenges and directions that the community needs to address. Additionally, we provide a collection of essential open-access resources, tools, and tutorials, available on our GitHub: https://github.com/mkhateri/Awesome-MRI-Super-Resolution. IEEE keywords: MRI, Super-Resolution, Deep Learning, Computational Imaging, Inverse Problem, Survey.

Harvard Harvard University
·
Nov 20, 2025 2

MedSAMix: A Training-Free Model Merging Approach for Medical Image Segmentation

Universal medical image segmentation models have emerged as a promising paradigm due to their strong generalizability across diverse tasks, showing great potential for a wide range of clinical applications. This potential has been partly driven by the success of general-purpose vision models such as the Segment Anything Model (SAM), which has inspired the development of various fine-tuned variants for medical segmentation tasks. However, fine-tuned variants like MedSAM are trained on comparatively limited medical imaging data that often suffers from heterogeneity, scarce annotations, and distributional shifts. These challenges limit their ability to generalize across a wide range of medical segmentation tasks. In this regard, we propose MedSAMix, a training-free model merging method that integrates the strengths of both generalist models (e.g., SAM) and specialist models (e.g., MedSAM) for medical image segmentation. In contrast to traditional model merging approaches that rely on manual configuration and often result in suboptimal outcomes, we propose a zero-order optimization method to automatically discover optimal layer-wise merging solutions. Furthermore, for clinical applications, we develop two regimes to meet the demand of domain-specificity and generalizability in different scenarios by single-task optimization and multi-objective optimization respectively. Extensive evaluations on 25 medical segmentation tasks demonstrate that MedSAMix effectively mitigates model bias and consistently improves performance in both domain-specific accuracy and generalization, achieving improvements of 6.67% on specialized tasks and 4.37% on multi-task evaluations.

  • 6 authors
·
Aug 14, 2025 2

Does DINOv3 Set a New Medical Vision Standard?

The advent of large-scale vision foundation models, pre-trained on diverse natural images, has marked a paradigm shift in computer vision. However, how the frontier vision foundation models' efficacies transfer to specialized domains remains such as medical imaging remains an open question. This report investigates whether DINOv3, a state-of-the-art self-supervised vision transformer (ViT) that features strong capability in dense prediction tasks, can directly serve as a powerful, unified encoder for medical vision tasks without domain-specific pre-training. To answer this, we benchmark DINOv3 across common medical vision tasks, including 2D/3D classification and segmentation on a wide range of medical imaging modalities. We systematically analyze its scalability by varying model sizes and input image resolutions. Our findings reveal that DINOv3 shows impressive performance and establishes a formidable new baseline. Remarkably, it can even outperform medical-specific foundation models like BiomedCLIP and CT-Net on several tasks, despite being trained solely on natural images. However, we identify clear limitations: The model's features degrade in scenarios requiring deep domain specialization, such as in Whole-Slide Pathological Images (WSIs), Electron Microscopy (EM), and Positron Emission Tomography (PET). Furthermore, we observe that DINOv3 does not consistently obey scaling law in the medical domain; performance does not reliably increase with larger models or finer feature resolutions, showing diverse scaling behaviors across tasks. Ultimately, our work establishes DINOv3 as a strong baseline, whose powerful visual features can serve as a robust prior for multiple complex medical tasks. This opens promising future directions, such as leveraging its features to enforce multiview consistency in 3D reconstruction.

  • 19 authors
·
Sep 8, 2025 3

Learning to Distill Global Representation for Sparse-View CT

Sparse-view computed tomography (CT) -- using a small number of projections for tomographic reconstruction -- enables much lower radiation dose to patients and accelerated data acquisition. The reconstructed images, however, suffer from strong artifacts, greatly limiting their diagnostic value. Current trends for sparse-view CT turn to the raw data for better information recovery. The resultant dual-domain methods, nonetheless, suffer from secondary artifacts, especially in ultra-sparse view scenarios, and their generalization to other scanners/protocols is greatly limited. A crucial question arises: have the image post-processing methods reached the limit? Our answer is not yet. In this paper, we stick to image post-processing methods due to great flexibility and propose global representation (GloRe) distillation framework for sparse-view CT, termed GloReDi. First, we propose to learn GloRe with Fourier convolution, so each element in GloRe has an image-wide receptive field. Second, unlike methods that only use the full-view images for supervision, we propose to distill GloRe from intermediate-view reconstructed images that are readily available but not explored in previous literature. The success of GloRe distillation is attributed to two key components: representation directional distillation to align the GloRe directions, and band-pass-specific contrastive distillation to gain clinically important details. Extensive experiments demonstrate the superiority of the proposed GloReDi over the state-of-the-art methods, including dual-domain ones. The source code is available at https://github.com/longzilicart/GloReDi.

  • 5 authors
·
Aug 16, 2023

Towards Robust and Generalizable Lensless Imaging with Modular Learned Reconstruction

Lensless cameras disregard the conventional design that imaging should mimic the human eye. This is done by replacing the lens with a thin mask, and moving image formation to the digital post-processing. State-of-the-art lensless imaging techniques use learned approaches that combine physical modeling and neural networks. However, these approaches make simplifying modeling assumptions for ease of calibration and computation. Moreover, the generalizability of learned approaches to lensless measurements of new masks has not been studied. To this end, we utilize a modular learned reconstruction in which a key component is a pre-processor prior to image recovery. We theoretically demonstrate the pre-processor's necessity for standard image recovery techniques (Wiener filtering and iterative algorithms), and through extensive experiments show its effectiveness for multiple lensless imaging approaches and across datasets of different mask types (amplitude and phase). We also perform the first generalization benchmark across mask types to evaluate how well reconstructions trained with one system generalize to others. Our modular reconstruction enables us to use pre-trained components and transfer learning on new systems to cut down weeks of tedious measurements and training. As part of our work, we open-source four datasets, and software for measuring datasets and for training our modular reconstruction.

  • 3 authors
·
Feb 3, 2025

Unsupervised Deep Learning for Limited-Angle STEM-EDX Tomography -- Application to 3D Chemical Analysis of Phase-Change Memory Devices

Energy Dispersive X-ray (EDX) tomography in Scanning Transmission Electron Microscopy (STEM) enables 3D compositional and elemental mapping at the nanoscale, but its use is limited by restricted tilt ranges and low-dose conditions required to avoid beam damage. Limited-angle acquisition introduces missing-wedge artefacts such as elongation and anisotropic resolution, while noisy low-dose data further degrade reconstruction quality and quantitative reliability. Here, we introduce an unsupervised deep learning framework based on Deep Image Prior with total variation regularization (DIP-TV) for limited-angle STEM-EDX tomography. We extend it to a multi-channel formulation (DIPm-TV) that jointly reconstructs multiple elemental maps by exploiting spatial correlations. Using a synthetic 3-channel phantom, we show that the method compensates for severe missing-wedge artefacts corresponding to approximately 100^circ of missing angular range under moderate noise, outperforming simultaneous iterative reconstruction technique and compressed sensing approaches. We apply the method to 3D chemical analysis of Ge-Sb-Te (GST) memory devices in virgin (as-fabricated) and SET (crystalline) operational states. Samples were prepared as cross-sectional focused ion beam lamellae and acquired under a limited-angle tilt range from -40^circ to +40^circ with 5^circ steps and a dose of 2.0times10^5 e^-/Ang^2. The multi-channel approach enables voxel-by-voxel elemental reconstruction using only EDX signals without external structural priors such as high-angle annular dark-field imaging. The reconstructed volumes show near-isotropic spatial resolution and reveal compositional heterogeneities associated with device operation. This approach enables 3D chemical characterization in experimentally accessible sample geometries where conventional methods fail due to severe angular limitations.

  • 6 authors
·
Jun 8

Differentiable Sensor Layouts for End-to-End Learning of Task-Specific Camera Parameters

The success of deep learning is frequently described as the ability to train all parameters of a network on a specific application in an end-to-end fashion. Yet, several design choices on the camera level, including the pixel layout of the sensor, are considered as pre-defined and fixed, and high resolution, regular pixel layouts are considered to be the most generic ones in computer vision and graphics, treating all regions of an image as equally important. While several works have considered non-uniform, \eg, hexagonal or foveated, pixel layouts in hardware and image processing, the layout has not been integrated into the end-to-end learning paradigm so far. In this work, we present the first truly end-to-end trained imaging pipeline that optimizes the size and distribution of pixels on the imaging sensor jointly with the parameters of a given neural network on a specific task. We derive an analytic, differentiable approach for the sensor layout parameterization that allows for task-specific, local varying pixel resolutions. We present two pixel layout parameterization functions: rectangular and curvilinear grid shapes that retain a regular topology. We provide a drop-in module that approximates sensor simulation given existing high-resolution images to directly connect our method with existing deep learning models. We show that network predictions benefit from learnable pixel layouts for two different downstream tasks, classification and semantic segmentation.

  • 6 authors
·
Apr 28, 2023

SKM-TEA: A Dataset for Accelerated MRI Reconstruction with Dense Image Labels for Quantitative Clinical Evaluation

Magnetic resonance imaging (MRI) is a cornerstone of modern medical imaging. However, long image acquisition times, the need for qualitative expert analysis, and the lack of (and difficulty extracting) quantitative indicators that are sensitive to tissue health have curtailed widespread clinical and research studies. While recent machine learning methods for MRI reconstruction and analysis have shown promise for reducing this burden, these techniques are primarily validated with imperfect image quality metrics, which are discordant with clinically-relevant measures that ultimately hamper clinical deployment and clinician trust. To mitigate this challenge, we present the Stanford Knee MRI with Multi-Task Evaluation (SKM-TEA) dataset, a collection of quantitative knee MRI (qMRI) scans that enables end-to-end, clinically-relevant evaluation of MRI reconstruction and analysis tools. This 1.6TB dataset consists of raw-data measurements of ~25,000 slices (155 patients) of anonymized patient MRI scans, the corresponding scanner-generated DICOM images, manual segmentations of four tissues, and bounding box annotations for sixteen clinically relevant pathologies. We provide a framework for using qMRI parameter maps, along with image reconstructions and dense image labels, for measuring the quality of qMRI biomarker estimates extracted from MRI reconstruction, segmentation, and detection techniques. Finally, we use this framework to benchmark state-of-the-art baselines on this dataset. We hope our SKM-TEA dataset and code can enable a broad spectrum of research for modular image reconstruction and image analysis in a clinically informed manner. Dataset access, code, and benchmarks are available at https://github.com/StanfordMIMI/skm-tea.

  • 12 authors
·
Mar 13, 2022

Fréchet Radiomic Distance (FRD): A Versatile Metric for Comparing Medical Imaging Datasets

Determining whether two sets of images belong to the same or different distributions or domains is a crucial task in modern medical image analysis and deep learning; for example, to evaluate the output quality of image generative models. Currently, metrics used for this task either rely on the (potentially biased) choice of some downstream task, such as segmentation, or adopt task-independent perceptual metrics (e.g., Fréchet Inception Distance/FID) from natural imaging, which we show insufficiently capture anatomical features. To this end, we introduce a new perceptual metric tailored for medical images, FRD (Fréchet Radiomic Distance), which utilizes standardized, clinically meaningful, and interpretable image features. We show that FRD is superior to other image distribution metrics for a range of medical imaging applications, including out-of-domain (OOD) detection, the evaluation of image-to-image translation (by correlating more with downstream task performance as well as anatomical consistency and realism), and the evaluation of unconditional image generation. Moreover, FRD offers additional benefits such as stability and computational efficiency at low sample sizes, sensitivity to image corruptions and adversarial attacks, feature interpretability, and correlation with radiologist-perceived image quality. Additionally, we address key gaps in the literature by presenting an extensive framework for the multifaceted evaluation of image similarity metrics in medical imaging -- including the first large-scale comparative study of generative models for medical image translation -- and release an accessible codebase to facilitate future research. Our results are supported by thorough experiments spanning a variety of datasets, modalities, and downstream tasks, highlighting the broad potential of FRD for medical image analysis.

  • 19 authors
·
Dec 2, 2024

Zero-Shot Low-dose CT Denoising via Sinogram Flicking

Many low-dose CT imaging methods rely on supervised learning, which requires a large number of paired noisy and clean images. However, obtaining paired images in clinical practice is challenging. To address this issue, zero-shot self-supervised methods train denoising networks using only the information within a single image, such as ZS-N2N. However, these methods often employ downsampling operations that degrade image resolution. Additionally, the training dataset is inherently constrained to the image itself. In this paper, we propose a zero-shot low-dose CT imaging method based on sinogram flicking, which operates within a single image but generates many copies via random conjugate ray matching. Specifically, two conjugate X-ray pencil beams measure the same path; their expected values should be identical, while their noise levels vary during measurements. By randomly swapping portions of the conjugate X-rays in the sinogram domain, we generate a large set of sinograms with consistent content but varying noise patterns. When displayed dynamically, these sinograms exhibit a flickering effect due to their identical structural content but differing noise patterns-hence the term sinogram flicking. We train the network on pairs of sinograms with the same content but different noise distributions using a lightweight model adapted from ZS-NSN. This process is repeated to obtain the final results. A simulation study demonstrates that our method outperforms state-of-the-art approaches such as ZS-N2N.

  • 2 authors
·
Apr 10, 2025

SAS: Segment Anything Small for Ultrasound -- A Non-Generative Data Augmentation Technique for Robust Deep Learning in Ultrasound Imaging

Accurate segmentation of anatomical structures in ultrasound (US) images, particularly small ones, is challenging due to noise and variability in imaging conditions (e.g., probe position, patient anatomy, tissue characteristics and pathology). To address this, we introduce Segment Anything Small (SAS), a simple yet effective scale- and texture-aware data augmentation technique designed to enhance the performance of deep learning models for segmenting small anatomical structures in ultrasound images. SAS employs a dual transformation strategy: (1) simulating diverse organ scales by resizing and embedding organ thumbnails into a black background, and (2) injecting noise into regions of interest to simulate varying tissue textures. These transformations generate realistic and diverse training data without introducing hallucinations or artifacts, improving the model's robustness to noise and variability. We fine-tuned a promptable foundation model on a controlled organ-specific medical imaging dataset and evaluated its performance on one internal and five external datasets. Experimental results demonstrate significant improvements in segmentation performance, with Dice score gains of up to 0.35 and an average improvement of 0.16 [95% CI 0.132,0.188]. Additionally, our iterative point prompts provide precise control and adaptive refinement, achieving performance comparable to bounding box prompts with just two points. SAS enhances model robustness and generalizability across diverse anatomical structures and imaging conditions, particularly for small structures, without compromising the accuracy of larger ones. By offering a computationally efficient solution that eliminates the need for extensive human labeling efforts, SAS emerges as a powerful tool for advancing medical image analysis, particularly in resource-constrained settings.

  • 5 authors
·
Mar 7, 2025

Few-Shot Video Object Segmentation in X-Ray Angiography Using Local Matching and Spatio-Temporal Consistency Loss

We introduce a novel FSVOS model that employs a local matching strategy to restrict the search space to the most relevant neighboring pixels. Rather than relying on inefficient standard im2col-like implementations (e.g., spatial convolutions, depthwise convolutions and feature-shifting mechanisms) or hardware-specific CUDA kernels (e.g., deformable and neighborhood attention), which often suffer from limited portability across non-CUDA devices, we reorganize the local sampling process through a direction-based sampling perspective. Specifically, we implement a non-parametric sampling mechanism that enables dynamically varying sampling regions. This approach provides the flexibility to adapt to diverse spatial structures without the computational costs of parametric layers and the need for model retraining. To further enhance feature coherence across frames, we design a supervised spatio-temporal contrastive learning scheme that enforces consistency in feature representations. In addition, we introduce a publicly available benchmark dataset for multi-object segmentation in X-ray angiography videos (MOSXAV), featuring detailed, manually labeled segmentation ground truth. Extensive experiments on the CADICA, XACV, and MOSXAV datasets show that our proposed FSVOS method outperforms current state-of-the-art video segmentation methods in terms of segmentation accuracy and generalization capability (i.e., seen and unseen categories). This work offers enhanced flexibility and potential for a wide range of clinical applications.

  • 3 authors
·
Jan 2

MedMNIST-C: Comprehensive benchmark and improved classifier robustness by simulating realistic image corruptions

The integration of neural-network-based systems into clinical practice is limited by challenges related to domain generalization and robustness. The computer vision community established benchmarks such as ImageNet-C as a fundamental prerequisite to measure progress towards those challenges. Similar datasets are largely absent in the medical imaging community which lacks a comprehensive benchmark that spans across imaging modalities and applications. To address this gap, we create and open-source MedMNIST-C, a benchmark dataset based on the MedMNIST+ collection covering 12 datasets and 9 imaging modalities. We simulate task and modality-specific image corruptions of varying severity to comprehensively evaluate the robustness of established algorithms against real-world artifacts and distribution shifts. We further provide quantitative evidence that our simple-to-use artificial corruptions allow for highly performant, lightweight data augmentation to enhance model robustness. Unlike traditional, generic augmentation strategies, our approach leverages domain knowledge, exhibiting significantly higher robustness when compared to widely adopted methods. By introducing MedMNIST-C and open-sourcing the corresponding library allowing for targeted data augmentations, we contribute to the development of increasingly robust methods tailored to the challenges of medical imaging. The code is available at https://github.com/francescodisalvo05/medmnistc-api .

  • 3 authors
·
Jun 25, 2024

TLNM: Externally Validated Tooth Detection, Numbering and Segmentation from Smartphone Photographs Using Mask R-CNN

Oral health issues affect billions globally, but the cost and limited access to professional dental care hinder preventive oral healthcare. Research relies on clinical-grade radiographs or intraoral camera images, unavailable for public self-screening. This study introduces a tooth localisation and numbering model for smartphone photographs. We developed a customised Mask Region-based Convolutional Neural Network (Mask R-CNN) pipeline trained on 1,272 annotated smartphone images. To address variability in patient-generated health data, the pipeline incorporates two domain-informed mechanisms: a masked gray-world white-balancing algorithm to mitigate artificial colour casts and an anatomically constrained detection layer to enforce structural validity and suppress false positives. Evaluation comprised four stages: internal held-out testing, independent external testing, a descriptive ablation study, and fold-based training stability analysis using the same internal test set. On the internal test set, the model achieved an instance-mask AP@50 of 0.818, class-aware PQ of 0.780, and operational F1 of 0.884. Training stability showed limited between-model variation: across ten runs, instance-mask AP@50 had a standard deviation of 0.009. On the external dataset, the model achieved an instance-mask AP@50 of 0.901, class-aware PQ of 0.832, and operational F1 of 0.928 despite differences in population, sensors, and acquisition protocols. The inference pipeline is available as an open-source, containerised API. These results demonstrate that consumer-grade smartphone imagery can support automated tooth-level anatomical mapping, offering a scalable, potentially low-cost foundation for remote screening and tele-dentistry in resource-constrained environments.

  • 5 authors
·
Aug 5

Differential privacy representation geometry for medical image analysis

Differential privacy (DP)'s effect in medical imaging is typically evaluated only through end-to-end performance, leaving the mechanism of privacy-induced utility loss unclear. We introduce Differential Privacy Representation Geometry for Medical Imaging (DP-RGMI), a framework that interprets DP as a structured transformation of representation space and decomposes performance degradation into encoder geometry and task-head utilization. Geometry is quantified by representation displacement from initialization and spectral effective dimension, while utilization is measured as the gap between linear-probe and end-to-end utility. Across over 594,000 images from four chest X-ray datasets and multiple pretrained initializations, we show that DP is consistently associated with a utilization gap even when linear separability is largely preserved. At the same time, displacement and spectral dimension exhibit non-monotonic, initialization- and dataset-dependent reshaping, indicating that DP alters representation anisotropy rather than uniformly collapsing features. Correlation analysis reveals that the association between end-to-end performance and utilization is robust across datasets but can vary by initialization, while geometric quantities capture additional prior- and dataset-conditioned variation. These findings position DP-RGMI as a reproducible framework for diagnosing privacy-induced failure modes and informing privacy model selection.

  • 4 authors
·
Mar 1

A Tutorial on MRI Reconstruction: From Modern Methods to Clinical Implications

MRI is an indispensable clinical tool, offering a rich variety of tissue contrasts to support broad diagnostic and research applications. Clinical exams routinely acquire multiple structural sequences that provide complementary information for differential diagnosis, while research protocols often incorporate advanced functional, diffusion, spectroscopic, and relaxometry sequences to capture multidimensional insights into tissue structure and composition. However, these capabilities come at the cost of prolonged scan times, which reduce patient throughput, increase susceptibility to motion artifacts, and may require trade-offs in image quality or diagnostic scope. Over the last two decades, advances in image reconstruction algorithms--alongside improvements in hardware and pulse sequence design--have made it possible to accelerate acquisitions while preserving diagnostic quality. Central to this progress is the ability to incorporate prior information to regularize the solutions to the reconstruction problem. In this tutorial, we overview the basics of MRI reconstruction and highlight state-of-the-art approaches, beginning with classical methods that rely on explicit hand-crafted priors, and then turning to deep learning methods that leverage a combination of learned and crafted priors to further push the performance envelope. We also explore the translational aspects and eventual clinical implications of these methods. We conclude by discussing future directions to address remaining challenges in MRI reconstruction. The tutorial is accompanied by a Python toolbox (https://github.com/tutorial-MRI-recon/tutorial) to demonstrate select methods discussed in the article.

  • 7 authors
·
Jul 22, 2025

UniMed-CLIP: Towards a Unified Image-Text Pretraining Paradigm for Diverse Medical Imaging Modalities

Vision-Language Models (VLMs) trained via contrastive learning have achieved notable success in natural image tasks. However, their application in the medical domain remains limited due to the scarcity of openly accessible, large-scale medical image-text datasets. Existing medical VLMs either train on closed-source proprietary or relatively small open-source datasets that do not generalize well. Similarly, most models remain specific to a single or limited number of medical imaging domains, again restricting their applicability to other modalities. To address this gap, we introduce UniMed, a large-scale, open-source multi-modal medical dataset comprising over 5.3 million image-text pairs across six diverse imaging modalities: X-ray, CT, MRI, Ultrasound, Pathology, and Fundus. UniMed is developed using a data-collection framework that leverages Large Language Models (LLMs) to transform modality-specific classification datasets into image-text formats while incorporating existing image-text data from the medical domain, facilitating scalable VLM pretraining. Using UniMed, we trained UniMed-CLIP, a unified VLM for six modalities that significantly outperforms existing generalist VLMs and matches modality-specific medical VLMs, achieving notable gains in zero-shot evaluations. For instance, UniMed-CLIP improves over BiomedCLIP (trained on proprietary data) by an absolute gain of +12.61, averaged over 21 datasets, while using 3x less training data. To facilitate future research, we release UniMed dataset, training codes, and models at https://github.com/mbzuai-oryx/UniMed-CLIP.

  • 5 authors
·
Dec 13, 2024

Distilling Photon-Counting CT into Routine Chest CT through Clinically Validated Degradation Modeling

Photon-counting CT (PCCT) provides superior image quality with higher spatial resolution and lower noise compared to conventional energy-integrating CT (EICT), but its limited clinical availability restricts large-scale research and clinical deployment. To bridge this gap, we propose SUMI, a simulated degradation-to-enhancement method that learns to reverse realistic acquisition artifacts in low-quality EICT by leveraging high-quality PCCT as reference. Our central insight is to explicitly model realistic acquisition degradations, transforming PCCT into clinically plausible lower-quality counterparts and learning to invert this process. The simulated degradations were validated for clinical realism by board-certified radiologists, enabling faithful supervision without requiring paired acquisitions at scale. As outcomes of this technical contribution, we: (1) train a latent diffusion model on 1,046 PCCTs, using an autoencoder first pre-trained on both these PCCTs and 405,379 EICTs from 145 hospitals to extract general CT latent features that we release for reuse in other generative medical imaging tasks; (2) construct a large-scale dataset of over 17,316 publicly available EICTs enhanced to PCCT-like quality, with radiologist-validated voxel-wise annotations of airway trees, arteries, veins, lungs, and lobes; and (3) demonstrate substantial improvements: across external data, SUMI outperforms state-of-the-art image translation methods by 15% in SSIM and 20% in PSNR, improves radiologist-rated clinical utility in reader studies, and enhances downstream top-ranking lesion detection performance, increasing sensitivity by up to 15% and F1 score by up to 10%. Our results suggest that emerging imaging advances can be systematically distilled into routine EICT using limited high-quality scans as reference.

  • 13 authors
·
Apr 7

UniH^3: Unifying Hierarchical Homogeneity and Heterogeneity for All-in-One Medical Image Restoration

All-in-One medical image restoration (MedIR) aims to address diverse tasks across modalities and degradation types using a single universal model. Existing methods typically prioritize modeling inter-task heterogeneity (e.g., distinct data distributions and degradation types). However, they largely neglect the inherent homogeneity present in medical images, such as widely shared anatomical structures within and across modalities, which can be leveraged to ease model training and improve generalization. To this end, we propose UniH3, a novel framework that Unifies Hierarchical Homogeneity and Heterogeneity for all-in-one medical image restoration. Specifically, to comprehensively exploit homogeneity, we introduce a Hierarchical Homogeneity Memory (H2M) module that progressively distills intra- and inter-task homogeneity priors from high-quality images during training, and adaptively retrieves the most relevant priors tailored to the input for guided restoration. These retrieved priors are then injected into the restoration pipeline via an efficient Homogeneity-Guided Attention (HGA) mechanism. Furthermore, to comprehensively address heterogeneity, we design a Hierarchical Heterogeneity Balancer (H2B) that mitigates both inter- and intra-task conflicts during optimization, facilitating balanced and effective multi-task learning. Extensive experiments on two large-scale benchmarks, MedIR-2D-500K and MedIR-3D-3K, demonstrate that UniH3 achieves state-of-the-art performance on both all-in-one and single-task medical image restoration. We hope this work establishes a strong benchmark and advances the development of general-purpose medical image restoration models. Code is available at https://github.com/Yaziwel/UniH3.

Removing Diffraction Image Artifacts in Under-Display Camera via Dynamic Skip Connection Network

Recent development of Under-Display Camera (UDC) systems provides a true bezel-less and notch-free viewing experience on smartphones (and TV, laptops, tablets), while allowing images to be captured from the selfie camera embedded underneath. In a typical UDC system, the microstructure of the semi-transparent organic light-emitting diode (OLED) pixel array attenuates and diffracts the incident light on the camera, resulting in significant image quality degradation. Oftentimes, noise, flare, haze, and blur can be observed in UDC images. In this work, we aim to analyze and tackle the aforementioned degradation problems. We define a physics-based image formation model to better understand the degradation. In addition, we utilize one of the world's first commodity UDC smartphone prototypes to measure the real-world Point Spread Function (PSF) of the UDC system, and provide a model-based data synthesis pipeline to generate realistically degraded images. We specially design a new domain knowledge-enabled Dynamic Skip Connection Network (DISCNet) to restore the UDC images. We demonstrate the effectiveness of our method through extensive experiments on both synthetic and real UDC data. Our physics-based image formation model and proposed DISCNet can provide foundations for further exploration in UDC image restoration, and even for general diffraction artifact removal in a broader sense.

  • 6 authors
·
Apr 19, 2021

A Unified Model for Compressed Sensing MRI Across Undersampling Patterns

Compressed Sensing MRI reconstructs images of the body's internal anatomy from undersampled measurements, thereby reducing scan time. Recently, deep learning has shown great potential for reconstructing high-fidelity images from highly undersampled measurements. However, one needs to train multiple models for different undersampling patterns and desired output image resolutions, since most networks operate on a fixed discretization. Such approaches are highly impractical in clinical settings, where undersampling patterns and image resolutions are frequently changed to accommodate different real-time imaging and diagnostic requirements. We propose a unified MRI reconstruction model robust to various measurement undersampling patterns and image resolutions. Our approach uses neural operators, a discretization-agnostic architecture applied in both image and measurement spaces, to capture local and global features. Empirically, our model improves SSIM by 11% and PSNR by 4 dB over a state-of-the-art CNN (End-to-End VarNet), with 600times faster inference than diffusion methods. The resolution-agnostic design also enables zero-shot super-resolution and extended field-of-view reconstruction, offering a versatile and efficient solution for clinical MR imaging. Our unified model offers a versatile solution for MRI, adapting seamlessly to various measurement undersampling and imaging resolutions, making it highly effective for flexible and reliable clinical imaging. Our code is available at https://armeet.ca/nomri.

  • 7 authors
·
Oct 5, 2024 1

Deep Learning Based Defect Detection for Solder Joints on Industrial X-Ray Circuit Board Images

Quality control is of vital importance during electronics production. As the methods of producing electronic circuits improve, there is an increasing chance of solder defects during assembling the printed circuit board (PCB). Many technologies have been incorporated for inspecting failed soldering, such as X-ray imaging, optical imaging, and thermal imaging. With some advanced algorithms, the new technologies are expected to control the production quality based on the digital images. However, current algorithms sometimes are not accurate enough to meet the quality control. Specialists are needed to do a follow-up checking. For automated X-ray inspection, joint of interest on the X-ray image is located by region of interest (ROI) and inspected by some algorithms. Some incorrect ROIs deteriorate the inspection algorithm. The high dimension of X-ray images and the varying sizes of image dimensions also challenge the inspection algorithms. On the other hand, recent advances on deep learning shed light on image-based tasks and are competitive to human levels. In this paper, deep learning is incorporated in X-ray imaging based quality control during PCB quality inspection. Two artificial intelligence (AI) based models are proposed and compared for joint defect detection. The noised ROI problem and the varying sizes of imaging dimension problem are addressed. The efficacy of the proposed methods are verified through experimenting on a real-world 3D X-ray dataset. By incorporating the proposed methods, specialist inspection workload is largely saved.

  • 10 authors
·
Aug 6, 2020

DuPLUS: Dual-Prompt Vision-Language Framework for Universal Medical Image Segmentation and Prognosis

Deep learning for medical imaging is hampered by task-specific models that lack generalizability and prognostic capabilities, while existing 'universal' approaches suffer from simplistic conditioning and poor medical semantic understanding. To address these limitations, we introduce DuPLUS, a deep learning framework for efficient multi-modal medical image analysis. DuPLUS introduces a novel vision-language framework that leverages hierarchical semantic prompts for fine-grained control over the analysis task, a capability absent in prior universal models. To enable extensibility to other medical tasks, it includes a hierarchical, text-controlled architecture driven by a unique dual-prompt mechanism. For segmentation, DuPLUS is able to generalize across three imaging modalities, ten different anatomically various medical datasets, encompassing more than 30 organs and tumor types. It outperforms the state-of-the-art task specific and universal models on 8 out of 10 datasets. We demonstrate extensibility of its text-controlled architecture by seamless integration of electronic health record (EHR) data for prognosis prediction, and on a head and neck cancer dataset, DuPLUS achieved a Concordance Index (CI) of 0.69. Parameter-efficient fine-tuning enables rapid adaptation to new tasks and modalities from varying centers, establishing DuPLUS as a versatile and clinically relevant solution for medical image analysis. The code for this work is made available at: https://anonymous.4open.science/r/DuPLUS-6C52

  • 6 authors
·
Oct 3, 2025

AI-Assisted Cervical Cancer Screening

Visual Inspection with Acetic Acid (VIA) remains the most feasible cervical cancer screening test in resource-constrained settings of low- and middle-income countries (LMICs), which are often performed screening camps or primary/community health centers by nurses instead of the preferred but unavailable expert Gynecologist. To address the highly subjective nature of the test, various handheld devices integrating cameras or smartphones have been recently explored to capture cervical images during VIA and aid decision-making via telemedicine or AI models. Most studies proposing AI models retrospectively use a relatively small number of already collected images from specific devices, digital cameras, or smartphones; the challenges and protocol for quality image acquisition during VIA in resource-constrained camp settings, challenges in getting gold standard, data imbalance, etc. are often overlooked. We present a novel approach and describe the end-to-end design process to build a robust smartphone-based AI-assisted system that does not require buying a separate integrated device: the proposed protocol for quality image acquisition in resource-constrained settings, dataset collected from 1,430 women during VIA performed by nurses in screening camps, preprocessing pipeline, and training and evaluation of a deep-learning-based classification model aimed to identify (pre)cancerous lesions. Our work shows that the readily available smartphones and a suitable protocol can capture the cervix images with the required details for the VIA test well; the deep-learning-based classification model provides promising results to assist nurses in VIA screening; and provides a direction for large-scale data collection and validation in resource-constrained settings.

  • 6 authors
·
Sep 3, 2024

Addressing Class Imbalance and Data Limitations in Advanced Node Semiconductor Defect Inspection: A Generative Approach for SEM Images

Precision in identifying nanometer-scale device-killer defects is crucial in both semiconductor research and development as well as in production processes. The effectiveness of existing ML-based approaches in this context is largely limited by the scarcity of data, as the production of real semiconductor wafer data for training these models involves high financial and time costs. Moreover, the existing simulation methods fall short of replicating images with identical noise characteristics, surface roughness and stochastic variations at advanced nodes. We propose a method for generating synthetic semiconductor SEM images using a diffusion model within a limited data regime. In contrast to images generated through conventional simulation methods, SEM images generated through our proposed DL method closely resemble real SEM images, replicating their noise characteristics and surface roughness adaptively. Our main contributions, which are validated on three different real semiconductor datasets, are: i) proposing a patch-based generative framework utilizing DDPM to create SEM images with intended defect classes, addressing challenges related to class-imbalance and data insufficiency, ii) demonstrating generated synthetic images closely resemble real SEM images acquired from the tool, preserving all imaging conditions and metrology characteristics without any metadata supervision, iii) demonstrating a defect detector trained on generated defect dataset, either independently or combined with a limited real dataset, can achieve similar or improved performance on real wafer SEM images during validation/testing compared to exclusive training on a real defect dataset, iv) demonstrating the ability of the proposed approach to transfer defect types, critical dimensions, and imaging conditions from one specified CD/Pitch and metrology specifications to another, thereby highlighting its versatility.

  • 5 authors
·
Jul 14, 2024

RF-ULM: Deep Learning for Radio-Frequency Ultrasound Localization Microscopy

In Ultrasound Localization Microscopy (ULM),achieving high-resolution images relies on the precise localization of contrast agent particles across consecutive beam-formed frames. However, our study uncovers an enormous potential: The process of delay-and-sum beamforming leads to an irreversible reduction of Radio-Frequency (RF) data, while its implications for localization remain largely unexplored. The rich contextual information embedded within RF wavefronts, including their hyperbolic shape and phase, offers great promise for guiding Deep Neural Networks (DNNs) in challenging localization scenarios. To fully exploit this data, we propose to directly localize scatterers in RF signals. Our approach involves a custom super-resolution DNN using learned feature channel shuffling and a novel semi-global convolutional sampling block tailored for reliable and accurate wavefront localization. Additionally, we introduce a geometric point transformation that facilitates seamless mapping between RF and B-mode coordinate space. To understand the impact of beamforming on ULM, we validate the effectiveness of our method by conducting an extensive comparison with State-Of-The-Art (SOTA) techniques. We present the inaugural in vivo results from an RF-trained DNN, highlighting its real-world practicality. Our findings show that RF-ULM bridges the domain gap between synthetic and real datasets, offering a considerable advantage in terms of precision and complexity. To enable the broader research community to benefit from our findings, our code and the associated SOTA methods are made available at https://github.com/hahnec/rf-ulm.

  • 5 authors
·
Oct 2, 2023

Conditional Denoising Diffusion Model-Based Robust MR Image Reconstruction from Highly Undersampled Data

Magnetic Resonance Imaging (MRI) is a critical tool in modern medical diagnostics, yet its prolonged acquisition time remains a critical limitation, especially in time-sensitive clinical scenarios. While undersampling strategies can accelerate image acquisition, they often result in image artifacts and degraded quality. Recent diffusion models have shown promise for reconstructing high-fidelity images from undersampled data by learning powerful image priors; however, most existing approaches either (i) rely on unsupervised score functions without paired supervision or (ii) apply data consistency only as a post-processing step. In this work, we introduce a conditional denoising diffusion framework with iterative data-consistency correction, which differs from prior methods by embedding the measurement model directly into every reverse diffusion step and training the model on paired undersampled-ground truth data. This hybrid design bridges generative flexibility with explicit enforcement of MRI physics. Experiments on the fastMRI dataset demonstrate that our framework consistently outperforms recent state-of-the-art deep learning and diffusion-based methods in SSIM, PSNR, and LPIPS, with LPIPS capturing perceptual improvements more faithfully. These results demonstrate that integrating conditional supervision with iterative consistency updates yields substantial improvements in both pixel-level fidelity and perceptual realism, establishing a principled and practical advance toward robust, accelerated MRI reconstruction.

  • 6 authors
·
Oct 7, 2025

IMPACT: A Generic Semantic Loss for Multimodal Medical Image Registration

Image registration is fundamental in medical imaging, enabling precise alignment of anatomical structures for diagnosis, treatment planning, image-guided treatment or longitudinal monitoring. This work introduces IMPACT (Image Metric with Pretrained model-Agnostic Comparison for Transmodality registration), a generic semantic similarity metric designed for seamless integration into diverse image registration frameworks (such as Elastix and Voxelmorph). It compares deep learning-based features extracted from medical images without requiring task-specific training, ensuring broad applicability across various modalities. By leveraging the features of the large-scale pretrained TotalSegmentator models and the ability to integrate Segment Anything Model (SAM) and other large-scale segmentation networks, this approach offers significant advantages. It provides robust, scalable, and efficient solutions for multimodal image registration. The IMPACT loss was evaluated on five challenging registration tasks involving thoracic CT/CBCT, and pelvic MR/CT datasets. Quantitative metrics, such as Target Registration Error and Dice Similarity Coefficient, demonstrated significant improvements in anatomical alignment compared to baseline methods. Qualitative analyses further confirmed the increased robustness of the proposed metric in the face of noise, artifacts, and modality variations. IMPACT's versatility and efficiency make it a valuable tool for advancing registration performance in clinical and research applications, addressing critical challenges in multimodal medical imaging.

  • 8 authors
·
Mar 31, 2025

LLM-CXR: Instruction-Finetuned LLM for CXR Image Understanding and Generation

Following the impressive development of LLMs, vision-language alignment in LLMs is actively being researched to enable multimodal reasoning and visual IO. This direction of research is particularly relevant to medical imaging because medical image analysis and generation consist of reasoning based on a combination of visual features and prior knowledge. Many recent works have focused on training adapter networks that serve as an information bridge between image processing networks and LLMs; but presumably, in order to achieve maximum reasoning potential of LLMs on visual information as well, visual and language features should be allowed to interact more freely. This is especially important in the medical domain because understanding and generating medical images such as chest X-rays (CXR) require not only accurate visual and language-based reasoning but also a more intimate mapping between the two modalities. Thus, taking inspiration from previous work on the transformer and VQ-GAN combination for bidirectional image and text generation, we build upon this approach and develop a method for instruction-tuning an LLM pre-trained only on text to gain vision-language capabilities for medical images. Specifically, we leverage a pretrained LLM's existing question-answering and instruction-following abilities to teach it to understand visual inputs by instructing it to answer questions about image inputs and, symmetrically, output both text and image responses appropriate to a given query by tuning the LLM with diverse tasks that encompass image-based text-generation and text-based image-generation. We show that our model, LLM-CXR, trained in this approach shows better image-text alignment in both CXR understanding and generation tasks while being smaller in size compared to previously developed models that perform a narrower range of tasks. The code is at https://github.com/hyn2028/llm-cxr.

  • 4 authors
·
May 19, 2023

Learning Sub-Sampling and Signal Recovery with Applications in Ultrasound Imaging

Limitations on bandwidth and power consumption impose strict bounds on data rates of diagnostic imaging systems. Consequently, the design of suitable (i.e. task- and data-aware) compression and reconstruction techniques has attracted considerable attention in recent years. Compressed sensing emerged as a popular framework for sparse signal reconstruction from a small set of compressed measurements. However, typical compressed sensing designs measure a (non)linearly weighted combination of all input signal elements, which poses practical challenges. These designs are also not necessarily task-optimal. In addition, real-time recovery is hampered by the iterative and time-consuming nature of sparse recovery algorithms. Recently, deep learning methods have shown promise for fast recovery from compressed measurements, but the design of adequate and practical sensing strategies remains a challenge. Here, we propose a deep learning solution termed Deep Probabilistic Sub-sampling (DPS), that learns a task-driven sub-sampling pattern, while jointly training a subsequent task model. Once learned, the task-based sub-sampling patterns are fixed and straightforwardly implementable, e.g. by non-uniform analog-to-digital conversion, sparse array design, or slow-time ultrasound pulsing schemes. The effectiveness of our framework is demonstrated in-silico for sparse signal recovery from partial Fourier measurements, and in-vivo for both anatomical image and tissue-motion (Doppler) reconstruction from sub-sampled medical ultrasound imaging data.

  • 5 authors
·
Aug 15, 2019

XFlow: A Workflow Model for Instruction-Guided Lesion Segmentation in Chest X-rays

Existing text-guided segmentation models in the medical domain cover only a narrow set of anatomical structures and lesions in chest X-rays (CXRs), and most of them assume that the queried target is always present in the image. Instruction-guided lesion segmentation (ILS) was introduced to overcome these limitations by segmenting diverse lesion types from simple user instructions while also recognizing when the queried lesion is absent, and ROSALIA was proposed as the first model for this task. However, the masks produced by ROSALIA remain of limited quality, often carrying scattered noise. Moreover, ROSALIA predicts the mask in a single shot, which differs fundamentally from how radiologists perceive and delineate lesions in practice. A radiologist first surveys the entire thorax, then localizes the approximate region of abnormality, and only then refines the lesion contour. Motivated by this coarse-to-fine, multi-level perception process, we present XFlow, a workflow model for ILS that combines box-based localization with multi-turn point refinement. XFlow detects the lungs, decides whether the queried finding is present in each of them, and prompts a fine-tuned SAM with the lesion box for an initial mask. It then corrects that mask through point prompts until its boundary follows the lesion, leaving every intermediate decision visible. Our experiments show that XFlow achieves the best segmentation quality on both internal and external evaluation. Notably, it surpasses ROSALIA in segmentation quality even when the two are trained on the same lesion annotations. Code and model weights will be made publicly available.

kaist-ai KAIST AI
·
Sep 27

LensNet: An End-to-End Learning Framework for Empirical Point Spread Function Modeling and Lensless Imaging Reconstruction

Lensless imaging stands out as a promising alternative to conventional lens-based systems, particularly in scenarios demanding ultracompact form factors and cost-effective architectures. However, such systems are fundamentally governed by the Point Spread Function (PSF), which dictates how a point source contributes to the final captured signal. Traditional lensless techniques often require explicit calibrations and extensive pre-processing, relying on static or approximate PSF models. These rigid strategies can result in limited adaptability to real-world challenges, including noise, system imperfections, and dynamic scene variations, thus impeding high-fidelity reconstruction. In this paper, we propose LensNet, an end-to-end deep learning framework that integrates spatial-domain and frequency-domain representations in a unified pipeline. Central to our approach is a learnable Coded Mask Simulator (CMS) that enables dynamic, data-driven estimation of the PSF during training, effectively mitigating the shortcomings of fixed or sparsely calibrated kernels. By embedding a Wiener filtering component, LensNet refines global structure and restores fine-scale details, thus alleviating the dependency on multiple handcrafted pre-processing steps. Extensive experiments demonstrate LensNet's robust performance and superior reconstruction quality compared to state-of-the-art methods, particularly in preserving high-frequency details and attenuating noise. The proposed framework establishes a novel convergence between physics-based modeling and data-driven learning, paving the way for more accurate, flexible, and practical lensless imaging solutions for applications ranging from miniature sensors to medical diagnostics. The link of code is https://github.com/baijiesong/Lensnet.

  • 6 authors
·
May 3, 2025

FS-RWKV: Leveraging Frequency Spatial-Aware RWKV for 3T-to-7T MRI Translation

Ultra-high-field 7T MRI offers enhanced spatial resolution and tissue contrast that enables the detection of subtle pathological changes in neurological disorders. However, the limited availability of 7T scanners restricts widespread clinical adoption due to substantial infrastructure costs and technical demands. Computational approaches for synthesizing 7T-quality images from accessible 3T acquisitions present a viable solution to this accessibility challenge. Existing CNN approaches suffer from limited spatial coverage, while Transformer models demand excessive computational overhead. RWKV architectures offer an efficient alternative for global feature modeling in medical image synthesis, combining linear computational complexity with strong long-range dependency capture. Building on this foundation, we propose Frequency Spatial-RWKV (FS-RWKV), an RWKV-based framework for 3T-to-7T MRI translation. To better address the challenges of anatomical detail preservation and global tissue contrast recovery, FS-RWKV incorporates two key modules: (1) Frequency-Spatial Omnidirectional Shift (FSO-Shift), which performs discrete wavelet decomposition followed by omnidirectional spatial shifting on the low-frequency branch to enhance global contextual representation while preserving high-frequency anatomical details; and (2) Structural Fidelity Enhancement Block (SFEB), a module that adaptively reinforces anatomical structure through frequency-aware feature fusion. Comprehensive experiments on UNC and BNU datasets demonstrate that FS-RWKV consistently outperforms existing CNN-, Transformer-, GAN-, and RWKV-based baselines across both T1w and T2w modalities, achieving superior anatomical fidelity and perceptual quality.

  • 5 authors
·
Oct 9, 2025

Vision-Language Generative Model for View-Specific Chest X-ray Generation

Synthetic medical data generation has opened up new possibilities in the healthcare domain, offering a powerful tool for simulating clinical scenarios, enhancing diagnostic and treatment quality, gaining granular medical knowledge, and accelerating the development of unbiased algorithms. In this context, we present a novel approach called ViewXGen, designed to overcome the limitations of existing methods that rely on general domain pipelines using only radiology reports to generate frontal-view chest X-rays. Our approach takes into consideration the diverse view positions found in the dataset, enabling the generation of chest X-rays with specific views, which marks a significant advancement in the field. To achieve this, we introduce a set of specially designed tokens for each view position, tailoring the generation process to the user's preferences. Furthermore, we leverage multi-view chest X-rays as input, incorporating valuable information from different views within the same study. This integration rectifies potential errors and contributes to faithfully capturing abnormal findings in chest X-ray generation. To validate the effectiveness of our approach, we conducted statistical analyses, evaluating its performance in a clinical efficacy metric on the MIMIC-CXR dataset. Also, human evaluation demonstrates the remarkable capabilities of ViewXGen, particularly in producing realistic view-specific X-rays that closely resemble the original images.

  • 8 authors
·
Feb 23, 2023

GL-LCM: Global-Local Latent Consistency Models for Fast High-Resolution Bone Suppression in Chest X-Ray Images

Chest X-Ray (CXR) imaging for pulmonary diagnosis raises significant challenges, primarily because bone structures can obscure critical details necessary for accurate diagnosis. Recent advances in deep learning, particularly with diffusion models, offer significant promise for effectively minimizing the visibility of bone structures in CXR images, thereby improving clarity and diagnostic accuracy. Nevertheless, existing diffusion-based methods for bone suppression in CXR imaging struggle to balance the complete suppression of bones with preserving local texture details. Additionally, their high computational demand and extended processing time hinder their practical use in clinical settings. To address these limitations, we introduce a Global-Local Latent Consistency Model (GL-LCM) architecture. This model combines lung segmentation, dual-path sampling, and global-local fusion, enabling fast high-resolution bone suppression in CXR images. To tackle potential boundary artifacts and detail blurring in local-path sampling, we further propose Local-Enhanced Guidance, which addresses these issues without additional training. Comprehensive experiments on a self-collected dataset SZCH-X-Rays, and the public dataset JSRT, reveal that our GL-LCM delivers superior bone suppression and remarkable computational efficiency, significantly outperforming several competitive methods. Our code is available at https://github.com/diaoquesang/GL-LCM.

  • 10 authors
·
Aug 5, 2025

SAM-Med3D: Towards General-purpose Segmentation Models for Volumetric Medical Images

Existing volumetric medical image segmentation models are typically task-specific, excelling at specific target but struggling to generalize across anatomical structures or modalities. This limitation restricts their broader clinical use. In this paper, we introduce SAM-Med3D for general-purpose segmentation on volumetric medical images. Given only a few 3D prompt points, SAM-Med3D can accurately segment diverse anatomical structures and lesions across various modalities. To achieve this, we gather and process a large-scale 3D medical image dataset, SA-Med3D-140K, from a blend of public sources and licensed private datasets. This dataset includes 22K 3D images and 143K corresponding 3D masks. Then SAM-Med3D, a promptable segmentation model characterized by the fully learnable 3D structure, is trained on this dataset using a two-stage procedure and exhibits impressive performance on both seen and unseen segmentation targets. We comprehensively evaluate SAM-Med3D on 16 datasets covering diverse medical scenarios, including different anatomical structures, modalities, targets, and zero-shot transferability to new/unseen tasks. The evaluation shows the efficiency and efficacy of SAM-Med3D, as well as its promising application to diverse downstream tasks as a pre-trained model. Our approach demonstrates that substantial medical resources can be utilized to develop a general-purpose medical AI for various potential applications. Our dataset, code, and models are available at https://github.com/uni-medical/SAM-Med3D.

  • 14 authors
·
Oct 23, 2023

RED-PSM: Regularization by Denoising of Partially Separable Models for Dynamic Imaging

Dynamic imaging addresses the recovery of a time-varying 2D or 3D object at each time instant using its undersampled measurements. In particular, in the case of dynamic tomography, only a single projection at a single view angle may be available at a time, making the problem severely ill-posed. In this work, we propose an approach, RED-PSM, which combines for the first time two powerful techniques to address this challenging imaging problem. The first, are partially separable models, which have been used to efficiently introduce a low-rank prior for the spatio-temporal object. The second is the recent Regularization by Denoising (RED), which provides a flexible framework to exploit the impressive performance of state-of-the-art image denoising algorithms, for various inverse problems. We propose a partially separable objective with RED and a computationally efficient and scalable optimization scheme with variable splitting and ADMM. Theoretical analysis proves the convergence of our objective to a value corresponding to a stationary point satisfying the first-order optimality conditions. Convergence is accelerated by a particular projection-domain-based initialization. We demonstrate the performance and computational improvements of our proposed RED-PSM with a learned image denoiser by comparing it to a recent deep-prior-based method known as TD-DIP. Although the main focus is on dynamic tomography, we also show the performance advantages of RED-PSM in a cardiac dynamic MRI setting.

  • 3 authors
·
Apr 7, 2023

Rapid patient-specific neural networks for intraoperative X-ray to volume registration

The integration of artificial intelligence in image-guided interventions holds transformative potential, promising to extract 3D geometric and quantitative information from conventional 2D imaging modalities during complex procedures. Achieving this requires the rapid and precise alignment of 2D intraoperative images (e.g., X-ray) with 3D preoperative volumes (e.g., CT, MRI). However, current 2D/3D registration methods fail across the broad spectrum of procedures dependent on X-ray guidance: traditional optimization techniques require custom parameter tuning for each subject, whereas neural networks trained on small datasets do not generalize to new patients or require labor-intensive manual annotations, increasing clinical burden and precluding application to new anatomical targets. To address these challenges, we present xvr, a fully automated framework for training patient-specific neural networks for 2D/3D registration. xvr uses physics-based simulation to generate abundant high-quality training data from a patient's own preoperative volumetric imaging, thereby overcoming the inherently limited ability of supervised models to generalize to new patients and procedures. Furthermore, xvr requires only 5 minutes of training per patient, making it suitable for emergency interventions as well as planned procedures. We perform the largest evaluation of a 2D/3D registration algorithm on real X-ray data to date and find that xvr robustly generalizes across a diverse dataset comprising multiple anatomical structures, imaging modalities, and hospitals. Across surgical tasks, xvr achieves submillimeter-accurate registration at intraoperative speeds, improving upon existing methods by an order of magnitude. xvr is released as open-source software freely available at https://github.com/eigenvivek/xvr.

  • 8 authors
·
Mar 20, 2025

BS-Diff: Effective Bone Suppression Using Conditional Diffusion Models from Chest X-Ray Images

Chest X-rays (CXRs) are commonly utilized as a low-dose modality for lung screening. Nonetheless, the efficacy of CXRs is somewhat impeded, given that approximately 75% of the lung area overlaps with bone, which in turn hampers the detection and diagnosis of diseases. As a remedial measure, bone suppression techniques have been introduced. The current dual-energy subtraction imaging technique in the clinic requires costly equipment and subjects being exposed to high radiation. To circumvent these issues, deep learning-based image generation algorithms have been proposed. However, existing methods fall short in terms of producing high-quality images and capturing texture details, particularly with pulmonary vessels. To address these issues, this paper proposes a new bone suppression framework, termed BS-Diff, that comprises a conditional diffusion model equipped with a U-Net architecture and a simple enhancement module to incorporate an autoencoder. Our proposed network cannot only generate soft tissue images with a high bone suppression rate but also possesses the capability to capture fine image details. Additionally, we compiled the largest dataset since 2010, including data from 120 patients with high-definition, high-resolution paired CXRs and soft tissue images collected by our affiliated hospital. Extensive experiments, comparative analyses, ablation studies, and clinical evaluations indicate that the proposed BS-Diff outperforms several bone-suppression models across multiple metrics. Our code can be accessed at https://github.com/Benny0323/BS-Diff.

  • 11 authors
·
Nov 26, 2023

Multicentric thrombus segmentation using an attention-based recurrent network with gradual modality dropout

Detecting and delineating tiny targets in 3D brain scans is a central yet under-addressed challenge in medical imaging.In ischemic stroke, for instance, the culprit thrombus is small, low-contrast, and variably expressed across modalities(e.g., susceptibility-weighted T2 blooming, diffusion restriction on DWI/ADC), while real-world multi-center dataintroduce domain shifts, anisotropy, and frequent missing sequences. We introduce a methodology that couples an attention-based recurrent segmentation network (UpAttLLSTM), a training schedule that progressively increases the difficulty of hetero-modal learning, with gradual modality dropout, UpAttLLSTM aggregates context across slices via recurrent units (2.5D) and uses attention gates to fuse complementary cues across available sequences, making it robust to anisotropy and class imbalance. Gradual modality dropout systematically simulates site heterogeneity,noise, and missing modalities during training, acting as both augmentation and regularization to improve multi-center generalization. On a monocentric cohort, our approach detects thrombi in >90% of cases with a Dice score of 0.65. In a multi-center setting with missing modalities, it achieves-80% detection with a Dice score around 0.35. Beyond stroke, the proposed methodology directly transfers to other small-lesion tasks in 3D medical imaging where targets are scarce, subtle, and modality-dependent

  • 4 authors
·
Mar 31

Dataset and Benchmark for Enhancing Critical Retained Foreign Object Detection

Critical retained foreign objects (RFOs), including surgical instruments like sponges and needles, pose serious patient safety risks and carry significant financial and legal implications for healthcare institutions. Detecting critical RFOs using artificial intelligence remains challenging due to their rarity and the limited availability of chest X-ray datasets that specifically feature critical RFOs cases. Existing datasets only contain non-critical RFOs, like necklace or zipper, further limiting their utility for developing clinically impactful detection algorithms. To address these limitations, we introduce "Hopkins RFOs Bench", the first and largest dataset of its kind, containing 144 chest X-ray images of critical RFO cases collected over 18 years from the Johns Hopkins Health System. Using this dataset, we benchmark several state-of-the-art object detection models, highlighting the need for enhanced detection methodologies for critical RFO cases. Recognizing data scarcity challenges, we further explore image synthetic methods to bridge this gap. We evaluate two advanced synthetic image methods, DeepDRR-RFO, a physics-based method, and RoentGen-RFO, a diffusion-based method, for creating realistic radiographs featuring critical RFOs. Our comprehensive analysis identifies the strengths and limitations of each synthetic method, providing insights into effectively utilizing synthetic data to enhance model training. The Hopkins RFOs Bench and our findings significantly advance the development of reliable, generalizable AI-driven solutions for detecting critical RFOs in clinical chest X-rays.

  • 16 authors
·
Jul 9, 2025

IVD-Net: Intervertebral disc localization and segmentation in MRI with a multi-modal UNet

Accurate localization and segmentation of intervertebral disc (IVD) is crucial for the assessment of spine disease diagnosis. Despite the technological advances in medical imaging, IVD localization and segmentation are still manually performed, which is time-consuming and prone to errors. If, in addition, multi-modal imaging is considered, the burden imposed on disease assessments increases substantially. In this paper, we propose an architecture for IVD localization and segmentation in multi-modal MRI, which extends the well-known UNet. Compared to single images, multi-modal data brings complementary information, contributing to better data representation and discriminative power. Our contributions are three-fold. First, how to effectively integrate and fully leverage multi-modal data remains almost unexplored. In this work, each MRI modality is processed in a different path to better exploit their unique information. Second, inspired by HyperDenseNet, the network is densely-connected both within each path and across different paths, granting the model the freedom to learn where and how the different modalities should be processed and combined. Third, we improved standard U-Net modules by extending inception modules with two dilated convolutions blocks of different scale, which helps handling multi-scale context. We report experiments over the data set of the public MICCAI 2018 Challenge on Automatic Intervertebral Disc Localization and Segmentation, with 13 multi-modal MRI images used for training and 3 for validation. We trained IVD-Net on an NVidia TITAN XP GPU with 16 GBs RAM, using ADAM as optimizer and a learning rate of 10e-5 during 200 epochs. Training took about 5 hours, and segmentation of a whole volume about 2-3 seconds, on average. Several baselines, with different multi-modal fusion strategies, were used to demonstrate the effectiveness of the proposed architecture.

  • 3 authors
·
Nov 19, 2018

Zeus: Zero-shot LLM Instruction for Union Segmentation in Multimodal Medical Imaging

Medical image segmentation has achieved remarkable success through the continuous advancement of UNet-based and Transformer-based foundation backbones. However, clinical diagnosis in the real world often requires integrating domain knowledge, especially textual information. Conducting multimodal learning involves visual and text modalities shown as a solution, but collecting paired vision-language datasets is expensive and time-consuming, posing significant challenges. Inspired by the superior ability in numerous cross-modal tasks for Large Language Models (LLMs), we proposed a novel Vision-LLM union framework to address the issues. Specifically, we introduce frozen LLMs for zero-shot instruction generation based on corresponding medical images, imitating the radiology scanning and report generation process. {To better approximate real-world diagnostic processes}, we generate more precise text instruction from multimodal radiology images (e.g., T1-w or T2-w MRI and CT). Based on the impressive ability of semantic understanding and rich knowledge of LLMs. This process emphasizes extracting special features from different modalities and reunion the information for the ultimate clinical diagnostic. With generated text instruction, our proposed union segmentation framework can handle multimodal segmentation without prior collected vision-language datasets. To evaluate our proposed method, we conduct comprehensive experiments with influential baselines, the statistical results and the visualized case study demonstrate the superiority of our novel method.}

  • 5 authors
·
Apr 8, 2025

XGLASS: X-Ray, Gaze and Language Assisted Slice Sequencing for CT Volumes

Vision-language models (VLMs) achieve remarkable performance on 2D medical images, such as X-rays or pathology images, while 3D VLMs that directly process CT/MRI volumes lag behind due to limited 3D training data and the predominance of 2D foundation architectures. To leverage powerful 2D VLMs for analyzing medical volumes, which contain hundreds of slices, it is therefore necessary to focus only on those few slices, which are diagnostically relevant. To enable such a prioritization, we propose XGLASS, a method that transfers medical expertise from 2D X-rays to 3D CT for task-aware slice prioritization. XGLASS uses disease-conditioned importance maps derived from language-aligned radiologist gaze on X-rays and spatially aligns them with coronal CT projections, bringing gaze priors and CT content into a shared 2D representation. The fused gaze-prior/CT projection is then used to predict a disease-specific ordering of axial slices, prioritizing diagnostically relevant slices. XGLASS significantly improves budgeted retrieval over 2D and 3D-native baselines, achieving a top-10 hit rate up to 75.9% for the best-performing disease. In practice, this means that after inspecting only the top 10 slices (4.17% of a 240-slice scan), XGLASS identifies a diagnostically relevant slice in more than 75% of cases. For downstream slice-wise finding classification, an XGLASS-selected 30-slice candidate set reduces model calls by 87.5% while improving F1 by 11.3 percentage points over all-slice inference, 4.2 points over the strongest 2D selector, and remains competitive with 3D-native selectors while requiring up to 130.8 times less time and 10.9 times less GPU memory per finding, supporting its use as a lightweight preselector for volumetric CT analysis. The code and pretrained checkpoint are available on https://github.com/michaelgloeckler/XGLASS.

  • 2 authors
·
Oct 18

Vision-Language Models for Automated 3D PET/CT Report Generation

Positron emission tomography/computed tomography (PET/CT) is essential in oncology, yet the rapid expansion of scanners has outpaced the availability of trained specialists, making automated PET/CT report generation (PETRG) increasingly important for reducing clinical workload. Compared with structural imaging (e.g., X-ray, CT, and MRI), functional PET poses distinct challenges: metabolic patterns vary with tracer physiology, and whole-body 3D contextual information is required rather than local-region interpretation. To advance PETRG, we propose PETRG-3D, an end-to-end 3D dual-branch framework that separately encodes PET and CT volumes and incorporates style-adaptive prompts to mitigate inter-hospital variability in reporting practices. We construct PETRG-Lym, a multi-center lymphoma dataset collected from four hospitals (824 reports w/ 245,509 paired PET/CT slices), and construct AutoPET-RG-Lym, a publicly accessible PETRG benchmark derived from open imaging data but equipped with new expert-written, clinically validated reports (135 cases). To assess clinical utility, we introduce PETRG-Score, a lymphoma-specific evaluation protocol that jointly measures metabolic and structural findings across curated anatomical regions. Experiments show that PETRG-3D substantially outperforms existing methods on both natural language metrics (e.g., +31.49\% ROUGE-L) and clinical efficacy metrics (e.g., +8.18\% PET-All), highlighting the benefits of volumetric dual-modality modeling and style-aware prompting. Overall, this work establishes a foundation for future PET/CT-specific models emphasizing disease-aware reasoning and clinically reliable evaluation. Codes, models, and AutoPET-RG-Lym will be released.

  • 11 authors
·
Nov 24, 2025

Healthy Counterfactual Generation via Diffusion Inpainting for Mammography Classification

False negatives remain a critical limitation of computer-aided diagnosis (CAD) systems for breast cancer screening due to delayed detection and treatment. To address this issue, we propose a counterfactual data augmentation strategy that generates healthy mammograms by "erasing" lesions from anomalous images, thereby enriching the training distribution. We train a Denoising Diffusion Probabilistic Model on BI-RADS 1 (healthy) mammograms and use a RePaint-based sampling strategy to inpaint realistic normal tissue within annotated lesion bounding boxes. The resulting healthy counterfactuals replace annotated lesion regions with realistic healthy tissue while preserving patient-specific anatomical structure, as supported by similarity metrics between real and generated images. Image realism was further assessed by radiologists and found to be consistent with the original dataset quality. We evaluate counterfactual augmentation across four representative classifier architectures: a convolutional neural network (ConvNeXt), a vision transformer (ViT), a vision-language model pre-trained on mammogram-report pairs (Mammo-CLIP) and a multi-scale attention-based multiple-instance learning framework (FPN-MIL). Experiments conducted on the VinDr-Mammo dataset show improvements in sensitivity across all architectures, particularly at 80\% fixed specificity, contributing towards more reliable CAD systems for breast cancer. Code is available at: https://github.com/ines03garcia/diffusion-based-counterfactual-generation.

  • 5 authors
·
Oct 7

End-to-end Adaptive Dynamic Subsampling and Reconstruction for Cardiac MRI

Background: Accelerating dynamic MRI is vital for advancing clinical applications and improving patient comfort. Commonly, deep learning (DL) methods for accelerated dynamic MRI reconstruction typically rely on uniformly applying non-adaptive predetermined or random subsampling patterns across all temporal frames of the dynamic acquisition. This approach fails to exploit temporal correlations or optimize subsampling on a case-by-case basis. Purpose: To develop an end-to-end approach for adaptive dynamic MRI subsampling and reconstruction, capable of generating customized sampling patterns maximizing at the same time reconstruction quality. Methods: We introduce the End-to-end Adaptive Dynamic Sampling and Reconstruction (E2E-ADS-Recon) for MRI framework, which integrates an adaptive dynamic sampler (ADS) that adapts the acquisition trajectory to each case for a given acceleration factor with a state-of-the-art dynamic reconstruction network, vSHARP, for reconstructing the adaptively sampled data into a dynamic image. The ADS can produce either frame-specific patterns or unified patterns applied to all temporal frames. E2E-ADS-Recon is evaluated under both frame-specific and unified 1D or 2D sampling settings, using dynamic cine cardiac MRI data and compared with vSHARP models employing standard subsampling trajectories, as well as pipelines where ADS was replaced by parameterized samplers optimized for dataset-specific schemes. Results: E2E-ADS-Recon exhibited superior reconstruction quality, especially at high accelerations, in terms of standard quantitative metrics (SSIM, pSNR, NMSE). Conclusion: The proposed framework improves reconstruction quality, highlighting the importance of case-specific subsampling optimization in dynamic MRI applications.

  • 3 authors
·
Mar 20, 2025

UHD-MFF: Shattering Barriers in Multi-Focus Ultra-High-Definition Image Fusion via Learnable Lookup Tables

With the advancement of imaging technology, ultra-high-definition images have become increasingly essential in modern visual applications. However, existing multi-focus image fusion remains largely confined to low-resolution images and faces three major barriers in UHD scenarios, namely data availability, model adaptability, and deployment feasibility, which severely hinder its practical application. To shatter these barriers, first, we propose the UHD-MFF dataset, the first large-scale ultra-high-resolution multi-focus fusion dataset. Second, we propose a scale-specialized lookup-table framework tailored for ultra-high-resolution images, termed as UMF-LUT. It consists of Coarse-Region Lookup Table (C-LUT) and Detail-Edge Lookup Table (D-LUT). Specifically, C-LUT performs joint queries of multiple gradient cues and semantic cues at low-resolution scales to enable region-level decision-making. Also, D-LUT operates at high-resolution scales, leveraging efficient Laplacian cues to provide complementary edge-level decision information. Such a design makes the model particularly well-suited for ultra-high-resolution multi-focus image fusion. Finally, it offers strong deployability with minimal computational overhead, enabling real-time 4K multi-focus fusion and showing promising potential for smartphone. Extensive experiments demonstrate that it outperforms SOTA methods in both visual fidelity and quantitative metrics. It effectively advances the development of multi-focus image fusion toward ultra-high-resolution imaging scenarios. The code is available at https://github.com/zyb5/UHD-MFF.

  • 6 authors
·
Jun 29

SynthRAD2023 Grand Challenge dataset: generating synthetic CT for radiotherapy

Purpose: Medical imaging has become increasingly important in diagnosing and treating oncological patients, particularly in radiotherapy. Recent advances in synthetic computed tomography (sCT) generation have increased interest in public challenges to provide data and evaluation metrics for comparing different approaches openly. This paper describes a dataset of brain and pelvis computed tomography (CT) images with rigidly registered CBCT and MRI images to facilitate the development and evaluation of sCT generation for radiotherapy planning. Acquisition and validation methods: The dataset consists of CT, CBCT, and MRI of 540 brains and 540 pelvic radiotherapy patients from three Dutch university medical centers. Subjects' ages ranged from 3 to 93 years, with a mean age of 60. Various scanner models and acquisition settings were used across patients from the three data-providing centers. Details are available in CSV files provided with the datasets. Data format and usage notes: The data is available on Zenodo (https://doi.org/10.5281/zenodo.7260705) under the SynthRAD2023 collection. The images for each subject are available in nifti format. Potential applications: This dataset will enable the evaluation and development of image synthesis algorithms for radiotherapy purposes on a realistic multi-center dataset with varying acquisition protocols. Synthetic CT generation has numerous applications in radiation therapy, including diagnosis, treatment planning, treatment monitoring, and surgical planning.

  • 9 authors
·
Mar 28, 2023

The MAMA-MIA Challenge: Advancing Generalizability and Fairness in Breast MRI Tumor Segmentation and Treatment Response Prediction

Breast cancer is the most frequently diagnosed malignancy among women worldwide and a leading cause of cancer-related mortality. Dynamic contrast-enhanced magnetic resonance imaging plays a central role in tumor characterization and treatment monitoring, particularly in patients receiving neoadjuvant chemotherapy. However, existing artificial intelligence models for breast magnetic resonance imaging are typically developed and evaluated using heterogeneous datasets, study populations, and assessment protocols, making direct comparison difficult and limiting understanding of model robustness across institutions and clinically relevant patient subgroups. The MAMA-MIA Challenge was designed to address these challenges by providing a standardized benchmark for the joint evaluation of primary tumor segmentation and prediction of pathologic complete response using pre-treatment magnetic resonance imaging only. The training cohort comprised 1,506 patients from multiple institutions in the United States, while evaluation was conducted on an external test set of 574 patients from three independent European centers to assess cross-continental and cross-institutional generalization. A unified scoring framework combined predictive performance with subgroup consistency across age, menopausal status, and breast density. Twenty-six international teams participated in the final evaluation phase. Results demonstrate substantial performance variability under a common external evaluation framework and reveal trade-offs between overall accuracy and subgroup fairness. The challenge provides standardized datasets, evaluation protocols, and public resources to promote the development of robust and equitable artificial intelligence systems for breast cancer imaging.

  • 46 authors
·
Jun 18

Deep Learning-Based Breast Cancer Detection in Mammography: A Multi-Center Validation Study in Thai Population

This study presents a deep learning system for breast cancer detection in mammography, developed using a modified EfficientNetV2 architecture with enhanced attention mechanisms. The model was trained on mammograms from a major Thai medical center and validated on three distinct datasets: an in-domain test set (9,421 cases), a biopsy-confirmed set (883 cases), and an out-of-domain generalizability set (761 cases) collected from two different hospitals. For cancer detection, the model achieved AUROCs of 0.89, 0.96, and 0.94 on the respective datasets. The system's lesion localization capability, evaluated using metrics including Lesion Localization Fraction (LLF) and Non-Lesion Localization Fraction (NLF), demonstrated robust performance in identifying suspicious regions. Clinical validation through concordance tests showed strong agreement with radiologists: 83.5% classification and 84.0% localization concordance for biopsy-confirmed cases, and 78.1% classification and 79.6% localization concordance for out-of-domain cases. Expert radiologists' acceptance rate also averaged 96.7% for biopsy-confirmed cases, and 89.3% for out-of-domain cases. The system achieved a System Usability Scale score of 74.17 for source hospital, and 69.20 for validation hospitals, indicating good clinical acceptance. These results demonstrate the model's effectiveness in assisting mammogram interpretation, with the potential to enhance breast cancer screening workflows in clinical practice.

  • 15 authors
·
May 29, 2025

PET2Rep: Towards Vision-Language Model-Drived Automated Radiology Report Generation for Positron Emission Tomography

Positron emission tomography (PET) is a cornerstone of modern oncologic and neurologic imaging, distinguished by its unique ability to illuminate dynamic metabolic processes that transcend the anatomical focus of traditional imaging technologies. Radiology reports are essential for clinical decision making, yet their manual creation is labor-intensive and time-consuming. Recent advancements of vision-language models (VLMs) have shown strong potential in medical applications, presenting a promising avenue for automating report generation. However, existing applications of VLMs in the medical domain have predominantly focused on structural imaging modalities, while the unique characteristics of molecular PET imaging have largely been overlooked. To bridge the gap, we introduce PET2Rep, a large-scale comprehensive benchmark for evaluation of general and medical VLMs for radiology report generation for PET images. PET2Rep stands out as the first dedicated dataset for PET report generation with metabolic information, uniquely capturing whole-body image-report pairs that cover dozens of organs to fill the critical gap in existing benchmarks and mirror real-world clinical comprehensiveness. In addition to widely recognized natural language generation metrics, we introduce a series of clinical efficiency metrics to evaluate the quality of radiotracer uptake pattern description in key organs in generated reports. We conduct a head-to-head comparison of 30 cutting-edge general-purpose and medical-specialized VLMs. The results show that the current state-of-the-art VLMs perform poorly on PET report generation task, falling considerably short of fulfilling practical needs. Moreover, we identify several key insufficiency that need to be addressed to advance the development in medical applications.

  • 15 authors
·
Aug 5, 2025

gQIR: Generative Quanta Image Reconstruction

Capturing high-quality images from only a few detected photons is a fundamental challenge in computational imaging. Single-photon avalanche diode (SPAD) sensors promise high-quality imaging in regimes where conventional cameras fail, but raw quanta frames contain only sparse, noisy, binary photon detections. Recovering a coherent image from a burst of such frames requires handling alignment, denoising, and demosaicing (for color) under noise statistics far outside those assumed by standard restoration pipelines or modern generative models. We present an approach that adapts large text-to-image latent diffusion models to the photon-limited domain of quanta burst imaging. Our method leverages the structural and semantic priors of internet-scale diffusion models while introducing mechanisms to handle Bernoulli photon statistics. By integrating latent-space restoration with burst-level spatio-temporal reasoning, our approach produces reconstructions that are both photometrically faithful and perceptually pleasing, even under high-speed motion. We evaluate the method on synthetic benchmarks and new real-world datasets, including the first color SPAD burst dataset and a challenging Deforming (XD) video benchmark. Across all settings, the approach substantially improves perceptual quality over classical and modern learning-based baselines, demonstrating the promise of adapting large generative priors to extreme photon-limited sensing. Code at https://github.com/Aryan-Garg/gQIR{https://github.com/Aryan-Garg/gQIR}.

  • 3 authors
·
Feb 23

Improving Lens Flare Removal with General Purpose Pipeline and Multiple Light Sources Recovery

When taking images against strong light sources, the resulting images often contain heterogeneous flare artifacts. These artifacts can importantly affect image visual quality and downstream computer vision tasks. While collecting real data pairs of flare-corrupted/flare-free images for training flare removal models is challenging, current methods utilize the direct-add approach to synthesize data. However, these methods do not consider automatic exposure and tone mapping in image signal processing pipeline (ISP), leading to the limited generalization capability of deep models training using such data. Besides, existing methods struggle to handle multiple light sources due to the different sizes, shapes and illuminance of various light sources. In this paper, we propose a solution to improve the performance of lens flare removal by revisiting the ISP and remodeling the principle of automatic exposure in the synthesis pipeline and design a more reliable light sources recovery strategy. The new pipeline approaches realistic imaging by discriminating the local and global illumination through convex combination, avoiding global illumination shifting and local over-saturation. Our strategy for recovering multiple light sources convexly averages the input and output of the neural network based on illuminance levels, thereby avoiding the need for a hard threshold in identifying light sources. We also contribute a new flare removal testing dataset containing the flare-corrupted images captured by ten types of consumer electronics. The dataset facilitates the verification of the generalization capability of flare removal methods. Extensive experiments show that our solution can effectively improve the performance of lens flare removal and push the frontier toward more general situations.

  • 6 authors
·
Aug 31, 2023