new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Oct 16

Discover, Falsify, Revise: Auditing Input-Use Claims from Source Code to Predictive Contribution in Agent-Discovered Cell Models

AI virtual cells aim to predict cellular responses to specified interventions, yet held-out predictive performance alone does not establish use of the supplied perturbation information. This prediction-claim gap matters in agentic model discovery, where language-model agents generate and revise predictors using score-based feedback. We introduce CELLAUDIT, which audits input-use claims by asking whether an input can enter the cited computation, whether fitted predictions depend on it, and whether that dependence improves prediction of observed response. On a paired morphology-transcriptomics perturbation benchmark (BBBC047), an agent-selected predictor attains a mean held-out Global Pearson correlation coefficient (PCC) of 0.3153 but remains invariant to compound replacement; a control-profile-only predictor reaches 0.3142. Source inspection identifies a compound-query pathway blocked by singleton key-value attention, and the invariance persists after refitting with disjoint control wells. In a stratified audit of 48 candidates across two linked tasks, 47 change predictions under compound replacement on both held-out folds, but only 20 show target-loss gains with intervals above zero on both folds. On BBBC047, falsification-guided revisions recover positive mean compound contributions while retaining gains over the control-profile-only baseline. In matched sci-Plex searches, audit-enriched feedback yields higher held-out performance and larger mean compound and dose contributions across five trajectories, although paired intervals span zero. Refitting fixed designs on an independently acquired cohort shows predictive generalization need not imply generalization of input-use claims: dose contribution persists, whereas support for compound identity does not. CELLAUDIT adds a falsification layer to agentic model discovery, moving from generate-score-revise toward discover-falsify-revise.

  • 6 authors
·
Sep 22

Generating synthetic computed tomography for radiotherapy: SynthRAD2025 challenge report

Radiation therapy (RT) requires precise dose delivery over multiple fractions, with CT fundamental for treatment planning due to its electron density information. Repeated CT acquisitions impose radiation exposure and logistical burdens, MRI lacks electron density, and cone-beam CT (CBCT) requires correction for dose calculation. Synthetic CT (sCT) generation addresses these by converting MRI or CBCT into CT-equivalent images with accurate Hounsfield Unit (HU) values, enabling MRI-only RT and CBCT-based adaptive workflows. Building on SynthRAD2023, SynthRAD2025 benchmarked sCT methods on 2,362 patients from five European centers across head and neck, thorax, and abdomen. Two tasks: MRI-to-CT (890 cases) and CBCT-to-CT (1,472 cases), evaluated via image similarity (MAE, PSNR, MS-SSIM), segmentation (Dice, HD95), and dosimetric metrics from photon and proton plans. With 803 participants and 12/13 valid submissions, Task 1 top performance reached MAE 64.8pm21.3 HU, PSNR sim30 dB, MS-SSIM sim0.936, Dice 0.79, photon γ_{2%/2mm}>98%, proton γapprox85%. Task 2 improved: MAE 48.3pm13.4 HU, PSNR 32.6 dB, MS-SSIM 0.968, Dice 0.86, photon γ>99%, proton γapprox89%. Strong image--segmentation correlations (ρ=0.78--0.79) but moderate dose correlations confirmed image quality is insufficient as a dosimetric surrogate. Head-and-neck cases were most consistent; thoracic and abdominal cases showed greater variability. Residual errors at tissue interfaces propagate along beam paths, affecting proton dose more than photon. SynthRAD2025 demonstrates that deep learning yields clinically relevant sCTs, especially for CBCT-to-CT, while identifying persistent MRI-to-CT challenges and underscoring dose-based evaluation as essential for clinical validation.

  • 33 authors
·
May 12

Sign-Constrained Intervention Effects for Domain-Generalizable ICU World Models

Predicting how a patient's vital signs respond to an intervention is a central question in intensive care. World models can do so by learning dynamics as a function of prior actions. However, such models tend to be brittle outside of training data. Clinicians choose drug dosages based on the patient's state, so the association a model learns between dose and outcome runs opposite to the drug's effect, generalizing poorly to out-of-distribution (OOD) dosing practices. Yet, pharmacological information provides the directional effects of different drugs, which are invariant to OOD shifts. To resolve the OOD sensitivity of current ICU world models, we introduce PHYSIO WORLD, which isolates an intervention's effect by evaluating a forward pass twice: once under recorded doses, and once with those doses set to zero. The difference is projected onto pharmacologically admissible effect directions stated by 70 rules over 28 drugs, leaving the magnitude to be learned from data. Across five distribution-shift parameters over cohorts from three intensive-care databases, and against forecasters, counterfactual models, and invariance objectives, PHYSIO WORLD attains the lowest OOD RMSE in every setting, improving on the strongest external baseline by 8-12%, while matching the in-distribution error of its backbone. Reversing the pharmacological directions degrades accuracy below the backbone, and data-mined directions recover almost no gain, indicating the improvement derives from the content of the pharmacological knowledge. The construction may extend to other settings where the sign of an effect is known in advance and its magnitude is confounded by treatment assignment.

  • 5 authors
·
Oct 7

Generating Synthetic Computed Tomography for Radiotherapy: SynthRAD2023 Challenge Report

Radiation therapy plays a crucial role in cancer treatment, necessitating precise delivery of radiation to tumors while sparing healthy tissues over multiple days. Computed tomography (CT) is integral for treatment planning, offering electron density data crucial for accurate dose calculations. However, accurately representing patient anatomy is challenging, especially in adaptive radiotherapy, where CT is not acquired daily. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast. Still, it lacks electron density information while cone beam CT (CBCT) lacks direct electron density calibration and is mainly used for patient positioning. Adopting MRI-only or CBCT-based adaptive radiotherapy eliminates the need for CT planning but presents challenges. Synthetic CT (sCT) generation techniques aim to address these challenges by using image synthesis to bridge the gap between MRI, CBCT, and CT. The SynthRAD2023 challenge was organized to compare synthetic CT generation methods using multi-center ground truth data from 1080 patients, divided into two tasks: 1) MRI-to-CT and 2) CBCT-to-CT. The evaluation included image similarity and dose-based metrics from proton and photon plans. The challenge attracted significant participation, with 617 registrations and 22/17 valid submissions for tasks 1/2. Top-performing teams achieved high structural similarity indices (>0.87/0.90) and gamma pass rates for photon (>98.1%/99.0%) and proton (>99.0%/97.3%) plans. However, no significant correlation was found between image similarity metrics and dose accuracy, emphasizing the need for dose evaluation when assessing the clinical applicability of sCT. SynthRAD2023 facilitated the investigation and benchmarking of sCT generation techniques, providing insights for developing MRI-only and CBCT-based adaptive radiotherapy.

  • 59 authors
·
Mar 13, 2024

Low-Dose CT Image Enhancement Using Deep Learning

The application of ionizing radiation for diagnostic imaging is common around the globe. However, the process of imaging, itself, remains to be a relatively hazardous operation. Therefore, it is preferable to use as low a dose of ionizing radiation as possible, particularly in computed tomography (CT) imaging systems, where multiple x-ray operations are performed for the reconstruction of slices of body tissues. A popular method for radiation dose reduction in CT imaging is known as the quarter-dose technique, which reduces the x-ray dose but can cause a loss of image sharpness. Since CT image reconstruction from directional x-rays is a nonlinear process, it is analytically difficult to correct the effect of dose reduction on image quality. Recent and popular deep-learning approaches provide an intriguing possibility of image enhancement for low-dose artifacts. Some recent works propose combinations of multiple deep-learning and classical methods for this purpose, which over-complicate the process. However, it is observed here that the straight utilization of the well-known U-NET provides very successful results for the correction of low-dose artifacts. Blind tests with actual radiologists reveal that the U-NET enhanced quarter-dose CT images not only provide an immense visual improvement over the low-dose versions, but also become diagnostically preferable images, even when compared to their full-dose CT versions.

  • 9 authors
·
Oct 31, 2023

SigmaMedStat: Temporal Signal Modeling for ICU False Alarm Reduction

Alarm fatigue in intensive care units (ICUs) is a well documented patient safety crisis. Clinical monitors generate 350 or more alarms per patient per day, out of which 72-99% are clinically irrelevant. Staff desensitization to non-actionable alarms increases the risk of missed true emergencies. This paper presents SigmaMedStat, a machine learning system that evaluates the trustworthiness of physiological alarm signals before clinical action is taken. Four approaches were evaluated on the PhysioNet/Computing in Cardiology Challenge 2015 dataset of 498 four-channel ICU alarm recordings. Primary contribution is a temporal modeling framework that splits each 60 second recording into six consecutive 10-second chunks, and this in turn generates Continuous Wavelet Transform (CWT) scalograms per chunk, encodes each chunk with a shared EfficientNet-B0 encoder, and passes the resulting feature sequence to a two-layer Long Short-Term Memory (LSTM) network. Five-fold stratified cross-validation yields a mean AUC of 0.822 +/- 0.016 (95% CI: [0.790,0.853]), compared to 0.641 for a static EfficientNet baseline trained on the full 60-second window. Ablation studies confirm that temporal chunking and multi-channel signal fusion both contribute independently to classification performance. Per-alarm type analysis reveals that Ventricular Flutter is the most accurately classified alarm type (AUC 0.820) while Asystole remains the hardest (AUC 0.722). Error analysis identifies 65 false negatives and 85 high-confidence misclassifications as the primary failure modes. All code and results are publicly available at https://github.com/Arun-K-Ram/sigmamedstat.

  • 1 authors
·
May 27

Any2Any 3D Diffusion Models with Knowledge Transfer: A Radiotherapy Planning Study

Voxel-wise dose prediction is a critical yet challenging task in practical radiotherapy (RT) planning, as bespoke models trained from scratch often struggle to generalize across diverse clinical settings. Meanwhile, generative models trained on billion-scale datasets from vision domains have achieved impressive performance. Herein, we propose DiffKT3D, a unified Any2Any 3D diffusion framework that leverages prior knowledge from pretrained video diffusion models for efficient and clinically meaningful dose prediction. To enable flexible conditioning across multiple clinical modalities (CT, anatomical structures, body, beam settings, etc.), we introduce an Any2Any conditional paradigm utilizing modality-specific embeddings without cross-attention overhead. Further, we design a novel reinforcement learning (RL) post-training mechanism guided by a clinically-informed Scorecard explicitly tailored to institutional treatment preferences. Compared with winner of GDP-HMM challenge, DiffKT3D sets a new state-of-the-art in dose prediction by reducing voxel-level MAE from 2.07 to 1.93. In addition, DiffKT3D achieves superior image quality and preference match. These results demonstrate that transferring diffusion priors via modality-aware conditioning and clinically aligned RL post-training can provide a robust and generalizable solution for RT planning across various clinical scenarios.

  • 10 authors
·
May 9

NutriOrion: A Hierarchical Multi-Agent Framework for Personalized Nutrition Intervention Grounded in Clinical Guidelines

Personalized nutrition intervention for patients with multimorbidity is critical for improving health outcomes, yet remains challenging because it requires the simultaneous integration of heterogeneous clinical conditions, medications, and dietary guidelines. Single-agent large language models (LLMs) often suffer from context overload and attention dilution when processing such high-dimensional patient profiles. We introduce NutriOrion, a hierarchical multi-agent framework with a parallel-then-sequential reasoning topology. NutriOrion decomposes nutrition planning into specialized domain agents with isolated contexts to mitigate anchoring bias, followed by a conditional refinement stage. The framework includes a multi-objective prioritization algorithm to resolve conflicting dietary requirements and a safety constraint mechanism that injects pharmacological contraindications as hard negative constraints during synthesis, ensuring clinical validity by construction rather than post-hoc filtering. For clinical interoperability, NutriOrion maps synthesized insights into the ADIME standard and FHIR R4 resources. Evaluated on 330 stroke patients with multimorbidity, NutriOrion outperforms multiple baselines, including GPT-4.1 and alternative multi-agent architectures. It achieves a 12.1 percent drug-food interaction violation rate, demonstrates strong personalization with negative correlations (-0.26 to -0.35) between patient biomarkers and recommended risk nutrients, and yields clinically meaningful dietary improvements, including a 167 percent increase in fiber and a 27 percent increase in potassium, alongside reductions in sodium (9 percent) and sugars (12 percent).

  • 10 authors
·
Feb 20