new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Oct 27

COBRA2026: a large-scale multicenter pelvic cone-beam computed tomography projection dataset

The COBRA2026 dataset is a large-scale, multicenter resource of raw radiotherapy cone-beam computed tomography (CBCT) acquisitions created for the development and evaluation of conventional and learning-based reconstruction and image-correction methods. It contains data from 867 patients undergoing pelvic radiotherapy at six European centers, acquired using Elekta and Varian imaging systems. For each case, the dataset includes raw projection data, acquisition geometry, calibration and correction information, clinically reconstructed CBCT images, and corresponding planning CT images. Vendor-specific files were anonymized and converted into open formats. Planning CT images were deformably registered to the daily CBCT anatomy, and matched projections were simulated using the corresponding acquisition geometry. All cases underwent visual quality control, and cases with substantial processing or registration errors were excluded. The approximately 950 GB dataset is divided into training, validation, and test sets containing 692, 52, and 123 cases, respectively. Projection stacks and volumetric images are provided as compressed MetaImage files, with geometry and metadata supplied in XML and YAML formats. COBRA2026 supports research on full- and sparse-view reconstruction, low-dose imaging, artifact and scatter correction, motion compensation, and synthetic CT generation. The dataset is released under the CC BY-NC 4.0 license, indexed on Zenodo (doi:10.5281/zenodo.21322350), and accompanied by openly available preprocessing and baseline reconstruction code. It also forms the basis of the COBRA2026 reconstruction challenge.

  • 14 authors
·
Jul 21

Zero-Shot Low-dose CT Denoising via Sinogram Flicking

Many low-dose CT imaging methods rely on supervised learning, which requires a large number of paired noisy and clean images. However, obtaining paired images in clinical practice is challenging. To address this issue, zero-shot self-supervised methods train denoising networks using only the information within a single image, such as ZS-N2N. However, these methods often employ downsampling operations that degrade image resolution. Additionally, the training dataset is inherently constrained to the image itself. In this paper, we propose a zero-shot low-dose CT imaging method based on sinogram flicking, which operates within a single image but generates many copies via random conjugate ray matching. Specifically, two conjugate X-ray pencil beams measure the same path; their expected values should be identical, while their noise levels vary during measurements. By randomly swapping portions of the conjugate X-rays in the sinogram domain, we generate a large set of sinograms with consistent content but varying noise patterns. When displayed dynamically, these sinograms exhibit a flickering effect due to their identical structural content but differing noise patterns-hence the term sinogram flicking. We train the network on pairs of sinograms with the same content but different noise distributions using a lightweight model adapted from ZS-NSN. This process is repeated to obtain the final results. A simulation study demonstrates that our method outperforms state-of-the-art approaches such as ZS-N2N.

  • 2 authors
·
Apr 10, 2025

Low-Dose CT Image Enhancement Using Deep Learning

The application of ionizing radiation for diagnostic imaging is common around the globe. However, the process of imaging, itself, remains to be a relatively hazardous operation. Therefore, it is preferable to use as low a dose of ionizing radiation as possible, particularly in computed tomography (CT) imaging systems, where multiple x-ray operations are performed for the reconstruction of slices of body tissues. A popular method for radiation dose reduction in CT imaging is known as the quarter-dose technique, which reduces the x-ray dose but can cause a loss of image sharpness. Since CT image reconstruction from directional x-rays is a nonlinear process, it is analytically difficult to correct the effect of dose reduction on image quality. Recent and popular deep-learning approaches provide an intriguing possibility of image enhancement for low-dose artifacts. Some recent works propose combinations of multiple deep-learning and classical methods for this purpose, which over-complicate the process. However, it is observed here that the straight utilization of the well-known U-NET provides very successful results for the correction of low-dose artifacts. Blind tests with actual radiologists reveal that the U-NET enhanced quarter-dose CT images not only provide an immense visual improvement over the low-dose versions, but also become diagnostically preferable images, even when compared to their full-dose CT versions.

  • 9 authors
·
Oct 31, 2023

Leveraging Semantic Asymmetry for Precise Gross Tumor Volume Segmentation of Nasopharyngeal Carcinoma in Planning CT

In the radiation therapy of nasopharyngeal carcinoma (NPC), clinicians typically delineate the gross tumor volume (GTV) using non-contrast planning computed tomography to ensure accurate radiation dose delivery. However, the low contrast between tumors and adjacent normal tissues necessitates that radiation oncologists manually delineate the tumors, often relying on diagnostic MRI for guidance. % In this study, we propose a novel approach to directly segment NPC gross tumors on non-contrast planning CT images, circumventing potential registration errors when aligning MRI or MRI-derived tumor masks to planning CT. To address the low contrast issues between tumors and adjacent normal structures in planning CT, we introduce a 3D Semantic Asymmetry Tumor segmentation (SATs) method. Specifically, we posit that a healthy nasopharyngeal region is characteristically bilaterally symmetric, whereas the emergence of nasopharyngeal carcinoma disrupts this symmetry. Then, we propose a Siamese contrastive learning segmentation framework that minimizes the voxel-wise distance between original and flipped areas without tumor and encourages a larger distance between original and flipped areas with tumor. Thus, our approach enhances the sensitivity of features to semantic asymmetries. % Extensive experiments demonstrate that the proposed SATs achieves the leading NPC GTV segmentation performance in both internal and external testing, e.g., with at least 2\% absolute Dice score improvement and 12\% average distance error reduction when compared to other state-of-the-art methods in the external testing.

  • 15 authors
·
Nov 27, 2024

Generating synthetic computed tomography for radiotherapy: SynthRAD2025 challenge report

Radiation therapy (RT) requires precise dose delivery over multiple fractions, with CT fundamental for treatment planning due to its electron density information. Repeated CT acquisitions impose radiation exposure and logistical burdens, MRI lacks electron density, and cone-beam CT (CBCT) requires correction for dose calculation. Synthetic CT (sCT) generation addresses these by converting MRI or CBCT into CT-equivalent images with accurate Hounsfield Unit (HU) values, enabling MRI-only RT and CBCT-based adaptive workflows. Building on SynthRAD2023, SynthRAD2025 benchmarked sCT methods on 2,362 patients from five European centers across head and neck, thorax, and abdomen. Two tasks: MRI-to-CT (890 cases) and CBCT-to-CT (1,472 cases), evaluated via image similarity (MAE, PSNR, MS-SSIM), segmentation (Dice, HD95), and dosimetric metrics from photon and proton plans. With 803 participants and 12/13 valid submissions, Task 1 top performance reached MAE 64.8pm21.3 HU, PSNR sim30 dB, MS-SSIM sim0.936, Dice 0.79, photon γ_{2%/2mm}>98%, proton γapprox85%. Task 2 improved: MAE 48.3pm13.4 HU, PSNR 32.6 dB, MS-SSIM 0.968, Dice 0.86, photon γ>99%, proton γapprox89%. Strong image--segmentation correlations (ρ=0.78--0.79) but moderate dose correlations confirmed image quality is insufficient as a dosimetric surrogate. Head-and-neck cases were most consistent; thoracic and abdominal cases showed greater variability. Residual errors at tissue interfaces propagate along beam paths, affecting proton dose more than photon. SynthRAD2025 demonstrates that deep learning yields clinically relevant sCTs, especially for CBCT-to-CT, while identifying persistent MRI-to-CT challenges and underscoring dose-based evaluation as essential for clinical validation.

  • 33 authors
·
May 12

Geometry-Aware Diffusion Approximate Posterior Sampling for Sparse-View and Limited-Angle CT

Sparse-view computed tomography (CT) reduces radiation dose and acquisition time and may mitigate motion artifacts. However, angular undersampling provides insufficient information to determine the image uniquely and stably. Limited-angle CT, arising from restricted angular coverage, produces strongly directional information loss associated with the missing angular range. In both settings, image directions may be strongly observed, weakly constrained, or unobservable, leading to severe ill-posedness and reconstruction ambiguity. Existing diffusion-based approaches incorporate measurement information through likelihood guidance, data-consistency operations, or range-null-space corrections. However, they do not generally use the continuously varying measurement sensitivity of the acquisition to jointly shape both reconstruction updates and stochastic exploration. We propose a geometry-aware diffusion-guided stochastic reconstruction framework for sparse-view and limited-angle CT. Its central component is a regularized noise-weighted pullback metric constructed from the CT forward operator and measurement-noise covariance. This metric continuously adapts both the measurement-aware update and stochastic exploration according to directional measurement sensitivity, suppressing changes along strongly constrained directions while permitting greater exploration along weakly constrained and unobservable directions. We complement this geometry-aware update with a regularized data-consistency correction and approximately null-space-restricted stochastic perturbations, implemented matrix-free using forward and backprojection operations together with conjugate-gradient solves. Experiments on sparse-view, noisy, and limited-angle CT demonstrate competitive reconstruction quality, strong measurement consistency, and spatially resolved empirical uncertainty estimates.

  • 3 authors
·
Oct 4

AI in Lung Health: Benchmarking Detection and Diagnostic Models Across Multiple CT Scan Datasets

Lung cancer remains the leading cause of cancer-related mortality worldwide, and early detection through low-dose computed tomography (LDCT) has shown significant promise in reducing death rates. With the growing integration of artificial intelligence (AI) into medical imaging, the development and evaluation of robust AI models require access to large, well-annotated datasets. In this study, we introduce the utility of Duke Lung Cancer Screening (DLCS) Dataset, the largest open-access LDCT dataset with over 2,000 scans and 3,000 expert-verified nodules. We benchmark deep learning models for both 3D nodule detection and lung cancer classification across internal and external datasets including LUNA16, LUNA25, and NLST-3D+. For detection, we develop two MONAI-based RetinaNet models (DLCSDmD and LUNA16-mD), evaluated using the Competition Performance Metric (CPM). For classification, we compare five models, including state-of-the-art pretrained models (Models Genesis, Med3D), a selfsupervised foundation model (FMCB), a randomly initialized ResNet50, and proposed a novel Strategic Warm-Start++ (SWS++) model. SWS++ uses curated candidate patches to pretrain a classification backbone within the same detection pipeline, enabling task-relevant feature learning. Our models demonstrated strong generalizability, with SWS++ achieving comparable or superior performance to existing foundational models across multiple datasets (AUC: 0.71 to 0.90). All code, models, and data are publicly released to promote reproducibility and collaboration. This work establishes a standardized benchmarking resource for lung cancer AI research, supporting future efforts in model development, validation, and clinical translation.

  • 7 authors
·
May 7, 2024

BS-Diff: Effective Bone Suppression Using Conditional Diffusion Models from Chest X-Ray Images

Chest X-rays (CXRs) are commonly utilized as a low-dose modality for lung screening. Nonetheless, the efficacy of CXRs is somewhat impeded, given that approximately 75% of the lung area overlaps with bone, which in turn hampers the detection and diagnosis of diseases. As a remedial measure, bone suppression techniques have been introduced. The current dual-energy subtraction imaging technique in the clinic requires costly equipment and subjects being exposed to high radiation. To circumvent these issues, deep learning-based image generation algorithms have been proposed. However, existing methods fall short in terms of producing high-quality images and capturing texture details, particularly with pulmonary vessels. To address these issues, this paper proposes a new bone suppression framework, termed BS-Diff, that comprises a conditional diffusion model equipped with a U-Net architecture and a simple enhancement module to incorporate an autoencoder. Our proposed network cannot only generate soft tissue images with a high bone suppression rate but also possesses the capability to capture fine image details. Additionally, we compiled the largest dataset since 2010, including data from 120 patients with high-definition, high-resolution paired CXRs and soft tissue images collected by our affiliated hospital. Extensive experiments, comparative analyses, ablation studies, and clinical evaluations indicate that the proposed BS-Diff outperforms several bone-suppression models across multiple metrics. Our code can be accessed at https://github.com/Benny0323/BS-Diff.

  • 11 authors
·
Nov 26, 2023

Learning to Distill Global Representation for Sparse-View CT

Sparse-view computed tomography (CT) -- using a small number of projections for tomographic reconstruction -- enables much lower radiation dose to patients and accelerated data acquisition. The reconstructed images, however, suffer from strong artifacts, greatly limiting their diagnostic value. Current trends for sparse-view CT turn to the raw data for better information recovery. The resultant dual-domain methods, nonetheless, suffer from secondary artifacts, especially in ultra-sparse view scenarios, and their generalization to other scanners/protocols is greatly limited. A crucial question arises: have the image post-processing methods reached the limit? Our answer is not yet. In this paper, we stick to image post-processing methods due to great flexibility and propose global representation (GloRe) distillation framework for sparse-view CT, termed GloReDi. First, we propose to learn GloRe with Fourier convolution, so each element in GloRe has an image-wide receptive field. Second, unlike methods that only use the full-view images for supervision, we propose to distill GloRe from intermediate-view reconstructed images that are readily available but not explored in previous literature. The success of GloRe distillation is attributed to two key components: representation directional distillation to align the GloRe directions, and band-pass-specific contrastive distillation to gain clinically important details. Extensive experiments demonstrate the superiority of the proposed GloReDi over the state-of-the-art methods, including dual-domain ones. The source code is available at https://github.com/longzilicart/GloReDi.

  • 5 authors
·
Aug 16, 2023

Active View Selection with Perturbed Gaussian Ensemble for Tomographic Reconstruction

Sparse-view computed tomography (CT) is critical for reducing radiation exposure to patients. Recent advances in radiative 3D Gaussian Splatting (3DGS) have enabled fast and accurate sparse-view CT reconstruction. Despite these algorithmic advancements, practical reconstruction fidelity remains fundamentally bounded by the quality of the captured data, raising the crucial yet underexplored problem of X-ray active view selection. Existing active view selection methods are primarily designed for natural-light scenes and fail to capture the unique geometric ambiguities and physical attenuation properties inherent in X-ray imaging. In this paper, we present Perturbed Gaussian Ensemble, an active view selection framework that integrates uncertainty modeling with sequential decision-making, tailored for X-ray Gaussian Splatting. Specifically, we identify low-density Gaussian primitives that are likely to be uncertain and apply stochastic density scaling to construct an ensemble of plausible Gaussian density fields. For each candidate projection, we measure the structural variance of the ensemble predictions and select the one with the highest variance as the next best view. Extensive experimental results on arbitrary-trajectory CT benchmarks demonstrate that our density-guided perturbation strategy effectively eliminates geometric artifacts and consistently outperforms existing baselines in progressive tomographic reconstruction under unified view selection protocols.

  • 6 authors
·
Jun 29

Generating Synthetic Computed Tomography for Radiotherapy: SynthRAD2023 Challenge Report

Radiation therapy plays a crucial role in cancer treatment, necessitating precise delivery of radiation to tumors while sparing healthy tissues over multiple days. Computed tomography (CT) is integral for treatment planning, offering electron density data crucial for accurate dose calculations. However, accurately representing patient anatomy is challenging, especially in adaptive radiotherapy, where CT is not acquired daily. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast. Still, it lacks electron density information while cone beam CT (CBCT) lacks direct electron density calibration and is mainly used for patient positioning. Adopting MRI-only or CBCT-based adaptive radiotherapy eliminates the need for CT planning but presents challenges. Synthetic CT (sCT) generation techniques aim to address these challenges by using image synthesis to bridge the gap between MRI, CBCT, and CT. The SynthRAD2023 challenge was organized to compare synthetic CT generation methods using multi-center ground truth data from 1080 patients, divided into two tasks: 1) MRI-to-CT and 2) CBCT-to-CT. The evaluation included image similarity and dose-based metrics from proton and photon plans. The challenge attracted significant participation, with 617 registrations and 22/17 valid submissions for tasks 1/2. Top-performing teams achieved high structural similarity indices (>0.87/0.90) and gamma pass rates for photon (>98.1%/99.0%) and proton (>99.0%/97.3%) plans. However, no significant correlation was found between image similarity metrics and dose accuracy, emphasizing the need for dose evaluation when assessing the clinical applicability of sCT. SynthRAD2023 facilitated the investigation and benchmarking of sCT generation techniques, providing insights for developing MRI-only and CBCT-based adaptive radiotherapy.

  • 59 authors
·
Mar 13, 2024

Sinogram upsampling using Primal-Dual UNet for undersampled CT and radial MRI reconstruction

Computed tomography and magnetic resonance imaging are two widely used clinical imaging modalities for non-invasive diagnosis. However, both of these modalities come with certain problems. CT uses harmful ionising radiation, and MRI suffers from slow acquisition speed. Both problems can be tackled by undersampling, such as sparse sampling. However, such undersampled data leads to lower resolution and introduces artefacts. Several techniques, including deep learning based methods, have been proposed to reconstruct such data. However, the undersampled reconstruction problem for these two modalities was always considered as two different problems and tackled separately by different research works. This paper proposes a unified solution for both sparse CT and undersampled radial MRI reconstruction, achieved by applying Fourier transform-based pre-processing on the radial MRI and then finally reconstructing both modalities using sinogram upsampling combined with filtered back-projection. The Primal-Dual network is a deep learning based method for reconstructing sparsely-sampled CT data. This paper introduces Primal-Dual UNet, which improves the Primal-Dual network in terms of accuracy and reconstruction speed. The proposed method resulted in an average SSIM of 0.932\textpm0.021 while performing sparse CT reconstruction for fan-beam geometry with a sparsity level of 16, achieving a statistically significant improvement over the previous model, which resulted in 0.919\textpm0.016. Furthermore, the proposed model resulted in 0.903\textpm0.019 and 0.957\textpm0.023 average SSIM while reconstructing undersampled brain and abdominal MRI data with an acceleration factor of 16, respectively - statistically significant improvements over the original model, which resulted in 0.867\textpm0.025 and 0.949\textpm0.025.

  • 5 authors
·
Dec 26, 2021

RibAssist 3D: Biplanar Rib-Fracture Detection, Addressing, and Selective 3D Localization from CT-Derived Projections

Rib fractures are common and time-consuming to localize on computed tomography (CT). We ask whether fractures detected independently in two orthogonal CT-derived projections (anteroposterior and lateral) can be paired across views and triangulated into reliable 3D points at a controlled rate of false outputs, and we answer it with a staged diagnostic study. The projection geometry is exact, and given correct correspondence, localization is accurate (median 4.0 mm, 88% within 10 mm, 93.6% rib-exact). On a sealed 55-case cohort, a large share of fractures is in principle recoverable (61.1% dual-view availability, and a correct pair present in the candidate graph for 58.4% of fractures), yet the binding limitation is neither geometry nor localization but confidence-limited cross-view correspondence. A controlled detector-by-correspondence factorial attributes the operational gain to lateral-detector quality rather than the tested matching methods; retraining the lateral detector produces the first nonzero controlled-budget reconstructions. Under a deliberately conservative commitment policy, a pre-specified sealed pass promotes 15 of 601 fractures to correct 3D localizations at 0.436 false points per case (2.50% end-to-end commitment yield), and committed points are accurate (median 1.49 mm, 93% rib-exact). The low yield is a consequence of confidence-gated abstention, not of geometry or detection: the study establishes a reproducible framework for selective 3D localization and identifies cross-view correspondence as the dominant operational bottleneck.

  • 1 authors
·
Aug 9 2

MInDI-3D: Iterative Deep Learning in 3D for Sparse-view Cone Beam Computed Tomography

We present MInDI-3D (Medical Inversion by Direct Iteration in 3D), the first 3D conditional diffusion-based model for real-world sparse-view Cone Beam Computed Tomography (CBCT) artefact removal, aiming to reduce imaging radiation exposure. A key contribution is extending the "InDI" concept from 2D to a full 3D volumetric approach for medical images, implementing an iterative denoising process that refines the CBCT volume directly from sparse-view input. A further contribution is the generation of a large pseudo-CBCT dataset (16,182) from chest CT volumes of the CT-RATE public dataset to robustly train MInDI-3D. We performed a comprehensive evaluation, including quantitative metrics, scalability analysis, generalisation tests, and a clinical assessment by 11 clinicians. Our results show MInDI-3D's effectiveness, achieving a 12.96 (6.10) dB PSNR gain over uncorrected scans with only 50 projections on the CT-RATE pseudo-CBCT (independent real-world) test set and enabling an 8x reduction in imaging radiation exposure. We demonstrate its scalability by showing that performance improves with more training data. Importantly, MInDI-3D matches the performance of a 3D U-Net on real-world scans from 16 cancer patients across distortion and task-based metrics. It also generalises to new CBCT scanner geometries. Clinicians rated our model as sufficient for patient positioning across all anatomical sites and found it preserved lung tumour boundaries well.

  • 10 authors
·
Aug 13, 2025

Saliency-Guided Deep Learning Network for Automatic Tumor Bed Volume Delineation in Post-operative Breast Irradiation

Efficient, reliable and reproducible target volume delineation is a key step in the effective planning of breast radiotherapy. However, post-operative breast target delineation is challenging as the contrast between the tumor bed volume (TBV) and normal breast tissue is relatively low in CT images. In this study, we propose to mimic the marker-guidance procedure in manual target delineation. We developed a saliency-based deep learning segmentation (SDL-Seg) algorithm for accurate TBV segmentation in post-operative breast irradiation. The SDL-Seg algorithm incorporates saliency information in the form of markers' location cues into a U-Net model. The design forces the model to encode the location-related features, which underscores regions with high saliency levels and suppresses low saliency regions. The saliency maps were generated by identifying markers on CT images. Markers' locations were then converted to probability maps using a distance-transformation coupled with a Gaussian filter. Subsequently, the CT images and the corresponding saliency maps formed a multi-channel input for the SDL-Seg network. Our in-house dataset was comprised of 145 prone CT images from 29 post-operative breast cancer patients, who received 5-fraction partial breast irradiation (PBI) regimen on GammaPod. The performance of the proposed method was compared against basic U-Net. Our model achieved mean (standard deviation) of 76.4 %, 6.76 mm, and 1.9 mm for DSC, HD95, and ASD respectively on the test set with computation time of below 11 seconds per one CT volume. SDL-Seg showed superior performance relative to basic U-Net for all the evaluation metrics while preserving low computation cost. The findings demonstrate that SDL-Seg is a promising approach for improving the efficiency and accuracy of the on-line treatment planning procedure of PBI, such as GammaPod based PBI.

  • 8 authors
·
May 6, 2021

Distilling Photon-Counting CT into Routine Chest CT through Clinically Validated Degradation Modeling

Photon-counting CT (PCCT) provides superior image quality with higher spatial resolution and lower noise compared to conventional energy-integrating CT (EICT), but its limited clinical availability restricts large-scale research and clinical deployment. To bridge this gap, we propose SUMI, a simulated degradation-to-enhancement method that learns to reverse realistic acquisition artifacts in low-quality EICT by leveraging high-quality PCCT as reference. Our central insight is to explicitly model realistic acquisition degradations, transforming PCCT into clinically plausible lower-quality counterparts and learning to invert this process. The simulated degradations were validated for clinical realism by board-certified radiologists, enabling faithful supervision without requiring paired acquisitions at scale. As outcomes of this technical contribution, we: (1) train a latent diffusion model on 1,046 PCCTs, using an autoencoder first pre-trained on both these PCCTs and 405,379 EICTs from 145 hospitals to extract general CT latent features that we release for reuse in other generative medical imaging tasks; (2) construct a large-scale dataset of over 17,316 publicly available EICTs enhanced to PCCT-like quality, with radiologist-validated voxel-wise annotations of airway trees, arteries, veins, lungs, and lobes; and (3) demonstrate substantial improvements: across external data, SUMI outperforms state-of-the-art image translation methods by 15% in SSIM and 20% in PSNR, improves radiologist-rated clinical utility in reader studies, and enhances downstream top-ranking lesion detection performance, increasing sensitivity by up to 15% and F1 score by up to 10%. Our results suggest that emerging imaging advances can be systematically distilled into routine EICT using limited high-quality scans as reference.

  • 13 authors
·
Apr 7

A multi-reconstruction study of breast density estimation using Deep Learning

Breast density estimation is one of the key tasks in recognizing individuals predisposed to breast cancer. It is often challenging because of low contrast and fluctuations in mammograms' fatty tissue background. Most of the time, the breast density is estimated manually where a radiologist assigns one of the four density categories decided by the Breast Imaging and Reporting Data Systems (BI-RADS). There have been efforts in the direction of automating a breast density classification pipeline. Breast density estimation is one of the key tasks performed during a screening exam. Dense breasts are more susceptible to breast cancer. The density estimation is challenging because of low contrast and fluctuations in mammograms' fatty tissue background. Traditional mammograms are being replaced by tomosynthesis and its other low radiation dose variants (for example Hologic' Intelligent 2D and C-View). Because of the low-dose requirement, increasingly more screening centers are favoring the Intelligent 2D view and C-View. Deep-learning studies for breast density estimation use only a single modality for training a neural network. However, doing so restricts the number of images in the dataset. In this paper, we show that a neural network trained on all the modalities at once performs better than a neural network trained on any single modality. We discuss these results using the area under the receiver operator characteristics curves.

  • 5 authors
·
Feb 16, 2022

DDoS-UNet: Incorporating temporal information using Dynamic Dual-channel UNet for enhancing super-resolution of dynamic MRI

Magnetic resonance imaging (MRI) provides high spatial resolution and excellent soft-tissue contrast without using harmful ionising radiation. Dynamic MRI is an essential tool for interventions to visualise movements or changes of the target organ. However, such MRI acquisition with high temporal resolution suffers from limited spatial resolution - also known as the spatio-temporal trade-off of dynamic MRI. Several approaches, including deep learning based super-resolution approaches, have been proposed to mitigate this trade-off. Nevertheless, such an approach typically aims to super-resolve each time-point separately, treating them as individual volumes. This research addresses the problem by creating a deep learning model which attempts to learn both spatial and temporal relationships. A modified 3D UNet model, DDoS-UNet, is proposed - which takes the low-resolution volume of the current time-point along with a prior image volume. Initially, the network is supplied with a static high-resolution planning scan as the prior image along with the low-resolution input to super-resolve the first time-point. Then it continues step-wise by using the super-resolved time-points as the prior image while super-resolving the subsequent time-points. The model performance was tested with 3D dynamic data that was undersampled to different in-plane levels. The proposed network achieved an average SSIM value of 0.951pm0.017 while reconstructing the lowest resolution data (i.e. only 4\% of the k-space acquired) - which could result in a theoretical acceleration factor of 25. The proposed approach can be used to reduce the required scan-time while achieving high spatial resolution.

  • 5 authors
·
Feb 10, 2022

Filter2Noise: Interpretable Self-Supervised Single-Image Denoising for Low-Dose CT with Attention-Guided Bilateral Filtering

Effective denoising is crucial in low-dose CT to enhance subtle structures and low-contrast lesions while preventing diagnostic errors. Supervised methods struggle with limited paired datasets, and self-supervised approaches often require multiple noisy images and rely on deep networks like U-Net, offering little insight into the denoising mechanism. To address these challenges, we propose an interpretable self-supervised single-image denoising framework -- Filter2Noise (F2N). Our approach introduces an Attention-Guided Bilateral Filter that adapted to each noisy input through a lightweight module that predicts spatially varying filter parameters, which can be visualized and adjusted post-training for user-controlled denoising in specific regions of interest. To enable single-image training, we introduce a novel downsampling shuffle strategy with a new self-supervised loss function that extends the concept of Noise2Noise to a single image and addresses spatially correlated noise. On the Mayo Clinic 2016 low-dose CT dataset, F2N outperforms the leading self-supervised single-image method (ZS-N2N) by 4.59 dB PSNR while improving transparency, user control, and parametric efficiency. These features provide key advantages for medical applications that require precise and interpretable noise reduction. Our code is demonstrated at https://github.com/sypsyp97/Filter2Noise.git .

  • 8 authors
·
Apr 18, 2025 2

Self-Supervised Pre-Training with Contrastive and Masked Autoencoder Methods for Dealing with Small Datasets in Deep Learning for Medical Imaging

Deep learning in medical imaging has the potential to minimize the risk of diagnostic errors, reduce radiologist workload, and accelerate diagnosis. Training such deep learning models requires large and accurate datasets, with annotations for all training samples. However, in the medical imaging domain, annotated datasets for specific tasks are often small due to the high complexity of annotations, limited access, or the rarity of diseases. To address this challenge, deep learning models can be pre-trained on large image datasets without annotations using methods from the field of self-supervised learning. After pre-training, small annotated datasets are sufficient to fine-tune the models for a specific task. The most popular self-supervised pre-training approaches in medical imaging are based on contrastive learning. However, recent studies in natural image processing indicate a strong potential for masked autoencoder approaches. Our work compares state-of-the-art contrastive learning methods with the recently introduced masked autoencoder approach "SparK" for convolutional neural networks (CNNs) on medical images. Therefore we pre-train on a large unannotated CT image dataset and fine-tune on several CT classification tasks. Due to the challenge of obtaining sufficient annotated training data in medical imaging, it is of particular interest to evaluate how the self-supervised pre-training methods perform when fine-tuning on small datasets. By experimenting with gradually reducing the training dataset size for fine-tuning, we find that the reduction has different effects depending on the type of pre-training chosen. The SparK pre-training method is more robust to the training dataset size than the contrastive methods. Based on our results, we propose the SparK pre-training for medical imaging tasks with only small annotated datasets.

  • 7 authors
·
Aug 12, 2023

CT to PET Translation: A Large-scale Dataset and Domain-Knowledge-Guided Diffusion Approach

Positron Emission Tomography (PET) and Computed Tomography (CT) are essential for diagnosing, staging, and monitoring various diseases, particularly cancer. Despite their importance, the use of PET/CT systems is limited by the necessity for radioactive materials, the scarcity of PET scanners, and the high cost associated with PET imaging. In contrast, CT scanners are more widely available and significantly less expensive. In response to these challenges, our study addresses the issue of generating PET images from CT images, aiming to reduce both the medical examination cost and the associated health risks for patients. Our contributions are twofold: First, we introduce a conditional diffusion model named CPDM, which, to our knowledge, is one of the initial attempts to employ a diffusion model for translating from CT to PET images. Second, we provide the largest CT-PET dataset to date, comprising 2,028,628 paired CT-PET images, which facilitates the training and evaluation of CT-to-PET translation models. For the CPDM model, we incorporate domain knowledge to develop two conditional maps: the Attention map and the Attenuation map. The former helps the diffusion process focus on areas of interest, while the latter improves PET data correction and ensures accurate diagnostic information. Experimental evaluations across various benchmarks demonstrate that CPDM surpasses existing methods in generating high-quality PET images in terms of multiple metrics. The source code and data samples are available at https://github.com/thanhhff/CPDM.

  • 8 authors
·
Oct 28, 2024

EchoVLM: Dynamic Mixture-of-Experts Vision-Language Model for Universal Ultrasound Intelligence

Ultrasound imaging has become the preferred imaging modality for early cancer screening due to its advantages of non-ionizing radiation, low cost, and real-time imaging capabilities. However, conventional ultrasound diagnosis heavily relies on physician expertise, presenting challenges of high subjectivity and low diagnostic efficiency. Vision-language models (VLMs) offer promising solutions for this issue, but existing general-purpose models demonstrate limited knowledge in ultrasound medical tasks, with poor generalization in multi-organ lesion recognition and low efficiency across multi-task diagnostics. To address these limitations, we propose EchoVLM, a vision-language model specifically designed for ultrasound medical imaging. The model employs a Mixture of Experts (MoE) architecture trained on data spanning seven anatomical regions. This design enables the model to perform multiple tasks, including ultrasound report generation, diagnosis and visual question-answering (VQA). The experimental results demonstrated that EchoVLM achieved significant improvements of 10.15 and 4.77 points in BLEU-1 scores and ROUGE-1 scores respectively compared to Qwen2-VL on the ultrasound report generation task. These findings suggest that EchoVLM has substantial potential to enhance diagnostic accuracy in ultrasound imaging, thereby providing a viable technical solution for future clinical applications. Source code and model weights are available at https://github.com/Asunatan/EchoVLM.

  • 5 authors
·
Sep 18, 2025 2

FluoroSAM: A Language-promptable Foundation Model for Flexible X-ray Image Segmentation

Language promptable X-ray image segmentation would enable greater flexibility for human-in-the-loop workflows in diagnostic and interventional precision medicine. Prior efforts have contributed task-specific models capable of solving problems within a narrow scope, but expanding to broader use requires additional data, annotations, and training time. Recently, language-aligned foundation models (LFMs) -- machine learning models trained on large amounts of highly variable image and text data thus enabling broad applicability -- have emerged as promising tools for automated image analysis. Existing foundation models for medical image analysis focus on scenarios and modalities where large, richly annotated datasets are available. However, the X-ray imaging modality features highly variable image appearance and applications, from diagnostic chest X-rays to interventional fluoroscopy, with varying availability of data. To pave the way toward an LFM for comprehensive and language-aligned analysis of arbitrary medical X-ray images, we introduce FluoroSAM, a language-promptable variant of the Segment Anything Model, trained from scratch on 3M synthetic X-ray images from a wide variety of human anatomies, imaging geometries, and viewing angles. These include pseudo-ground truth masks for 128 organ types and 464 tools with associated text descriptions. FluoroSAM is capable of segmenting myriad anatomical structures and tools based on natural language prompts, thanks to the novel incorporation of vector quantization (VQ) of text embeddings in the training process. We demonstrate FluoroSAM's performance quantitatively on real X-ray images and showcase on several applications how FluoroSAM is a key enabler for rich human-machine interaction in the X-ray image acquisition and analysis context. Code is available at https://github.com/arcadelab/fluorosam.

  • 8 authors
·
Mar 12, 2024

Stabilize, Decompose, and Denoise: Self-Supervised Fluoroscopy Denoising

Fluoroscopy is an imaging technique that uses X-ray to obtain a real-time 2D video of the interior of a 3D object, helping surgeons to observe pathological structures and tissue functions especially during intervention. However, it suffers from heavy noise that mainly arises from the clinical use of a low dose X-ray, thereby necessitating the technology of fluoroscopy denoising. Such denoising is challenged by the relative motion between the object being imaged and the X-ray imaging system. We tackle this challenge by proposing a self-supervised, three-stage framework that exploits the domain knowledge of fluoroscopy imaging. (i) Stabilize: we first construct a dynamic panorama based on optical flow calculation to stabilize the non-stationary background induced by the motion of the X-ray detector. (ii) Decompose: we then propose a novel mask-based Robust Principle Component Analysis (RPCA) decomposition method to separate a video with detector motion into a low-rank background and a sparse foreground. Such a decomposition accommodates the reading habit of experts. (iii) Denoise: we finally denoise the background and foreground separately by a self-supervised learning strategy and fuse the denoised parts into the final output via a bilateral, spatiotemporal filter. To assess the effectiveness of our work, we curate a dedicated fluoroscopy dataset of 27 videos (1,568 frames) and corresponding ground truth. Our experiments demonstrate that it achieves significant improvements in terms of denoising and enhancement effects when compared with standard approaches. Finally, expert rating confirms this efficacy.

  • 6 authors
·
Aug 29, 2022

Vision-Language Modeling in PET/CT for Visual Grounding of Positive Findings

Vision-language models can connect the text description of an object to its specific location in an image through visual grounding. This has potential applications in enhanced radiology reporting. However, these models require large annotated image-text datasets, which are lacking for PET/CT. We developed an automated pipeline to generate weak labels linking PET/CT report descriptions to their image locations and used it to train a 3D vision-language visual grounding model. Our pipeline finds positive findings in PET/CT reports by identifying mentions of SUVmax and axial slice numbers. From 25,578 PET/CT exams, we extracted 11,356 sentence-label pairs. Using this data, we trained ConTEXTual Net 3D, which integrates text embeddings from a large language model with a 3D nnU-Net via token-level cross-attention. The model's performance was compared against LLMSeg, a 2.5D version of ConTEXTual Net, and two nuclear medicine physicians. The weak-labeling pipeline accurately identified lesion locations in 98% of cases (246/251), with 7.5% requiring boundary adjustments. ConTEXTual Net 3D achieved an F1 score of 0.80, outperforming LLMSeg (F1=0.22) and the 2.5D model (F1=0.53), though it underperformed both physicians (F1=0.94 and 0.91). The model achieved better performance on FDG (F1=0.78) and DCFPyL (F1=0.75) exams, while performance dropped on DOTATE (F1=0.58) and Fluciclovine (F1=0.66). The model performed consistently across lesion sizes but showed reduced accuracy on lesions with low uptake. Our novel weak labeling pipeline accurately produced an annotated dataset of PET/CT image-text pairs, facilitating the development of 3D visual grounding models. ConTEXTual Net 3D significantly outperformed other models but fell short of the performance of nuclear medicine physicians. Our study suggests that even larger datasets may be needed to close this performance gap.

  • 10 authors
·
Feb 1, 2025

Conditional Denoising Diffusion Model-Based Robust MR Image Reconstruction from Highly Undersampled Data

Magnetic Resonance Imaging (MRI) is a critical tool in modern medical diagnostics, yet its prolonged acquisition time remains a critical limitation, especially in time-sensitive clinical scenarios. While undersampling strategies can accelerate image acquisition, they often result in image artifacts and degraded quality. Recent diffusion models have shown promise for reconstructing high-fidelity images from undersampled data by learning powerful image priors; however, most existing approaches either (i) rely on unsupervised score functions without paired supervision or (ii) apply data consistency only as a post-processing step. In this work, we introduce a conditional denoising diffusion framework with iterative data-consistency correction, which differs from prior methods by embedding the measurement model directly into every reverse diffusion step and training the model on paired undersampled-ground truth data. This hybrid design bridges generative flexibility with explicit enforcement of MRI physics. Experiments on the fastMRI dataset demonstrate that our framework consistently outperforms recent state-of-the-art deep learning and diffusion-based methods in SSIM, PSNR, and LPIPS, with LPIPS capturing perceptual improvements more faithfully. These results demonstrate that integrating conditional supervision with iterative consistency updates yields substantial improvements in both pixel-level fidelity and perceptual realism, establishing a principled and practical advance toward robust, accelerated MRI reconstruction.

  • 6 authors
·
Oct 7, 2025

BS-LDM: Effective Bone Suppression in High-Resolution Chest X-Ray Images with Conditional Latent Diffusion Models

Lung diseases represent a significant global health challenge, with Chest X-Ray (CXR) being a key diagnostic tool due to their accessibility and affordability. Nonetheless, the detection of pulmonary lesions is often hindered by overlapping bone structures in CXR images, leading to potential misdiagnoses. To address this issue, we developed an end-to-end framework called BS-LDM, designed to effectively suppress bone in high-resolution CXR images. This framework is based on conditional latent diffusion models and incorporates a multi-level hybrid loss-constrained vector-quantized generative adversarial network which is crafted for perceptual compression, ensuring the preservation of details. To further enhance the framework's performance, we introduce offset noise and a temporal adaptive thresholding strategy. These additions help minimize discrepancies in generating low-frequency information, thereby improving the clarity of the generated soft tissue images. Additionally, we have compiled a high-quality bone suppression dataset named SZCH-X-Rays. This dataset includes 818 pairs of high-resolution CXR and dual-energy subtraction soft tissue images collected from a partner hospital. Moreover, we processed 241 data pairs from the JSRT dataset into negative images, which are more commonly used in clinical practice. Our comprehensive experimental and clinical evaluations reveal that BS-LDM excels in bone suppression, underscoring its significant clinical value.

  • 10 authors
·
Dec 20, 2024

Deep End-to-end Adaptive k-Space Sampling, Reconstruction, and Registration for Dynamic MRI

Dynamic MRI enables a range of clinical applications, including cardiac function assessment, organ motion tracking, and radiotherapy guidance. However, fully sampling the dynamic k-space data is often infeasible due to time constraints and physiological motion such as respiratory and cardiac motion. This necessitates undersampling, which degrades the quality of reconstructed images. Poor image quality not only hinders visualization but also impairs the estimation of deformation fields, crucial for registering dynamic (moving) images to a static reference image. This registration enables tasks such as motion correction, treatment planning, and quantitative analysis in applications like cardiac imaging and MR-guided radiotherapy. To overcome the challenges posed by undersampling and motion, we introduce an end-to-end deep learning (DL) framework that integrates adaptive dynamic k-space sampling, reconstruction, and registration. Our approach begins with a DL-based adaptive sampling strategy, optimizing dynamic k-space acquisition to capture the most relevant data for each specific case. This is followed by a DL-based reconstruction module that produces images optimized for accurate deformation field estimation from the undersampled moving data. Finally, a registration module estimates the deformation fields aligning the reconstructed dynamic images with a static reference. The proposed framework is independent of specific reconstruction and registration modules allowing for plug-and-play integration of these components. The entire framework is jointly trained using a combination of supervised and unsupervised loss functions, enabling end-to-end optimization for improved performance across all components. Through controlled experiments and ablation studies, we validate each component, demonstrating that each choice contributes to robust motion estimation from undersampled dynamic data.

  • 3 authors
·
Mar 20, 2025

SynthRAD2023 Grand Challenge dataset: generating synthetic CT for radiotherapy

Purpose: Medical imaging has become increasingly important in diagnosing and treating oncological patients, particularly in radiotherapy. Recent advances in synthetic computed tomography (sCT) generation have increased interest in public challenges to provide data and evaluation metrics for comparing different approaches openly. This paper describes a dataset of brain and pelvis computed tomography (CT) images with rigidly registered CBCT and MRI images to facilitate the development and evaluation of sCT generation for radiotherapy planning. Acquisition and validation methods: The dataset consists of CT, CBCT, and MRI of 540 brains and 540 pelvic radiotherapy patients from three Dutch university medical centers. Subjects' ages ranged from 3 to 93 years, with a mean age of 60. Various scanner models and acquisition settings were used across patients from the three data-providing centers. Details are available in CSV files provided with the datasets. Data format and usage notes: The data is available on Zenodo (https://doi.org/10.5281/zenodo.7260705) under the SynthRAD2023 collection. The images for each subject are available in nifti format. Potential applications: This dataset will enable the evaluation and development of image synthesis algorithms for radiotherapy purposes on a realistic multi-center dataset with varying acquisition protocols. Synthetic CT generation has numerous applications in radiation therapy, including diagnosis, treatment planning, treatment monitoring, and surgical planning.

  • 9 authors
·
Mar 28, 2023

SPARSE Data, Rich Results: Few-Shot Semi-Supervised Learning via Class-Conditioned Image Translation

Deep learning has revolutionized medical imaging, but its effectiveness is severely limited by insufficient labeled training data. This paper introduces a novel GAN-based semi-supervised learning framework specifically designed for low labeled-data regimes, evaluated across settings with 5 to 50 labeled samples per class. Our approach integrates three specialized neural networks -- a generator for class-conditioned image translation, a discriminator for authenticity assessment and classification, and a dedicated classifier -- within a three-phase training framework. The method alternates between supervised training on limited labeled data and unsupervised learning that leverages abundant unlabeled images through image-to-image translation rather than generation from noise. We employ ensemble-based pseudo-labeling that combines confidence-weighted predictions from the discriminator and classifier with temporal consistency through exponential moving averaging, enabling reliable label estimation for unlabeled data. Comprehensive evaluation across eleven MedMNIST datasets demonstrates that our approach achieves statistically significant improvements over six state-of-the-art GAN-based semi-supervised methods, with particularly strong performance in the extreme 5-shot setting where the scarcity of labeled data is most challenging. The framework maintains its superiority across all evaluated settings (5, 10, 20, and 50 shots per class). Our approach offers a practical solution for medical imaging applications where annotation costs are prohibitive, enabling robust classification performance even with minimal labeled data. Code is available at https://github.com/GuidoManni/SPARSE.

  • 4 authors
·
Aug 8, 2025 2

SKM-TEA: A Dataset for Accelerated MRI Reconstruction with Dense Image Labels for Quantitative Clinical Evaluation

Magnetic resonance imaging (MRI) is a cornerstone of modern medical imaging. However, long image acquisition times, the need for qualitative expert analysis, and the lack of (and difficulty extracting) quantitative indicators that are sensitive to tissue health have curtailed widespread clinical and research studies. While recent machine learning methods for MRI reconstruction and analysis have shown promise for reducing this burden, these techniques are primarily validated with imperfect image quality metrics, which are discordant with clinically-relevant measures that ultimately hamper clinical deployment and clinician trust. To mitigate this challenge, we present the Stanford Knee MRI with Multi-Task Evaluation (SKM-TEA) dataset, a collection of quantitative knee MRI (qMRI) scans that enables end-to-end, clinically-relevant evaluation of MRI reconstruction and analysis tools. This 1.6TB dataset consists of raw-data measurements of ~25,000 slices (155 patients) of anonymized patient MRI scans, the corresponding scanner-generated DICOM images, manual segmentations of four tissues, and bounding box annotations for sixteen clinically relevant pathologies. We provide a framework for using qMRI parameter maps, along with image reconstructions and dense image labels, for measuring the quality of qMRI biomarker estimates extracted from MRI reconstruction, segmentation, and detection techniques. Finally, we use this framework to benchmark state-of-the-art baselines on this dataset. We hope our SKM-TEA dataset and code can enable a broad spectrum of research for modular image reconstruction and image analysis in a clinically informed manner. Dataset access, code, and benchmarks are available at https://github.com/StanfordMIMI/skm-tea.

  • 12 authors
·
Mar 13, 2022

Parameter-Efficient Adaptation of SAM 3 for Automated ITV Generation from 4DCT Images

Four-dimensional computed tomography (4DCT) captures the full respiratory cycle of thoracic anatomy, yet current Internal Target Volume contouring workflows process each phase in isolation, discarding temporal coherence and leaving contours vulnerable to phase-specific artifacts. We present a lightweight framework that applies parameter-efficient fine-tuning to the Segment Anything Model 3 (SAM 3) via low-rank adaptation (LoRA) to align its text-prompted segmentation with the medical domain using only seven annotated 3D CT volumes. Furthermore, the framework incorporates a hard negative mining strategy to improve boundary discrimination in low-contrast thoracic regions. At inference, phase-wise predictions are refined through phase-coherent temporal filtering and spatial connectivity analysis. Since respiratory motion is continuous and periodic, genuine anatomy appears in contiguous blocks of phases, whereas transient artifacts appear sporadically and are thus effectively suppressed. Experiments on pulmonary and cardiac structures yield median Dice scores of 0.968 and 0.910 with 95th-percentile Hausdorff distances of 0.998 mm and 2.931 mm, respectively. The proposed framework effectively eliminates the severe false-positive predictions inherent in the zero-shot inference of the unadapted SAM 3. With only seven annotated volumes, the framework retains over 95% of full-data accuracy, and the entire pipeline is trainable on a single consumer-grade GPU, demonstrating a scalable, data-efficient solution for adaptive radiotherapy.

  • 1 authors
·
Jun 13

Unsupervised Deep Learning for Limited-Angle STEM-EDX Tomography -- Application to 3D Chemical Analysis of Phase-Change Memory Devices

Energy Dispersive X-ray (EDX) tomography in Scanning Transmission Electron Microscopy (STEM) enables 3D compositional and elemental mapping at the nanoscale, but its use is limited by restricted tilt ranges and low-dose conditions required to avoid beam damage. Limited-angle acquisition introduces missing-wedge artefacts such as elongation and anisotropic resolution, while noisy low-dose data further degrade reconstruction quality and quantitative reliability. Here, we introduce an unsupervised deep learning framework based on Deep Image Prior with total variation regularization (DIP-TV) for limited-angle STEM-EDX tomography. We extend it to a multi-channel formulation (DIPm-TV) that jointly reconstructs multiple elemental maps by exploiting spatial correlations. Using a synthetic 3-channel phantom, we show that the method compensates for severe missing-wedge artefacts corresponding to approximately 100^circ of missing angular range under moderate noise, outperforming simultaneous iterative reconstruction technique and compressed sensing approaches. We apply the method to 3D chemical analysis of Ge-Sb-Te (GST) memory devices in virgin (as-fabricated) and SET (crystalline) operational states. Samples were prepared as cross-sectional focused ion beam lamellae and acquired under a limited-angle tilt range from -40^circ to +40^circ with 5^circ steps and a dose of 2.0times10^5 e^-/Ang^2. The multi-channel approach enables voxel-by-voxel elemental reconstruction using only EDX signals without external structural priors such as high-angle annular dark-field imaging. The reconstructed volumes show near-isotropic spatial resolution and reveal compositional heterogeneities associated with device operation. This approach enables 3D chemical characterization in experimentally accessible sample geometries where conventional methods fail due to severe angular limitations.

  • 6 authors
·
Jun 8

Multi-RADS Synthetic Radiology Report Dataset and Head-to-Head Benchmarking of 41 Open-Weight and Proprietary Language Models

Background: Reporting and Data Systems (RADS) standardize radiology risk communication but automated RADS assignment from narrative reports is challenging because of guideline complexity, output-format constraints, and limited benchmarking across RADS frameworks and model sizes. Purpose: To create RXL-RADSet, a radiologist-verified synthetic multi-RADS benchmark, and compare validity and accuracy of open-weight small language models (SLMs) with a proprietary model for RADS assignment. Materials and Methods: RXL-RADSet contains 1,600 synthetic radiology reports across 10 RADS (BI-RADS, CAD-RADS, GB-RADS, LI-RADS, Lung-RADS, NI-RADS, O-RADS, PI-RADS, TI-RADS, VI-RADS) and multiple modalities. Reports were generated by LLMs using scenario plans and simulated radiologist styles and underwent two-stage radiologist verification. We evaluated 41 quantized SLMs (12 families, 0.135-32B parameters) and GPT-5.2 under a fixed guided prompt. Primary endpoints were validity and accuracy; a secondary analysis compared guided versus zero-shot prompting. Results: Under guided prompting GPT-5.2 achieved 99.8% validity and 81.1% accuracy (1,600 predictions). Pooled SLMs (65,600 predictions) achieved 96.8% validity and 61.1% accuracy; top SLMs in the 20-32B range reached ~99% validity and mid-to-high 70% accuracy. Performance scaled with model size (inflection between <1B and >=10B) and declined with RADS complexity primarily due to classification difficulty rather than invalid outputs. Guided prompting improved validity (99.2% vs 96.7%) and accuracy (78.5% vs 69.6%) compared with zero-shot. Conclusion: RXL-RADSet provides a radiologist-verified multi-RADS benchmark; large SLMs (20-32B) can approach proprietary-model performance under guided prompting, but gaps remain for higher-complexity schemes.

  • 25 authors
·
Jan 6

PhyMRI-SR: Toward Physics-Aware MRI Image Super-Resolution

Magnetic resonance imaging (MRI) super-resolution is vital for improving diagnostic accessibility, yet most methods treat it as a deterministic mapping from a fixed low-resolution input to a high-resolution target. This overlooks a key property of MRI acquisition physics: spatial resolution and signal-to-noise ratio (SNR) are inherently coupled, making any given low-resolution scan merely one of many possible realizations under varying acquisition trade-offs. We rethink MRI super-resolution as a physics-aware reconstruction problem, in which the goal is to identify the optimal resolution-SNR configuration and then super-resolve it to obtain high-quality MRI results. A key implication of this formulation is that MRI resolution becomes dynamic rather than fixed. To handle such resolution-heterogeneous inputs, we adapt 2D Gaussian Splatting (2D GS) to MRI by formulating reconstruction as a coordinate-based, resolution-agnostic rendering problem. To further enhance fidelity, we introduce three innovations: (1) a prior-aware Gaussian representation that combines an Anatomical Structure Prior for tissue-specific kernel initialization with an Imaging System Prior that captures hardware characteristics via a covariance dictionary; (2) a physics-constrained signal modeling scheme that predicts intrinsic tissue parameters (proton density rho and effective relaxation rate R2) and synthesizes intensities through governing physical equations, ensuring biophysically plausible contrast; and (3) a meta-learning framework that alleviates paired-data scarcity by pretraining on simulated data and adapting to real-world conditions. Extensive experiments on dynamic-resolution datasets and standard benchmarks demonstrate that our method achieves state-of-the-art performance, highlighting its strong potential for clinical deployment.

GL-LCM: Global-Local Latent Consistency Models for Fast High-Resolution Bone Suppression in Chest X-Ray Images

Chest X-Ray (CXR) imaging for pulmonary diagnosis raises significant challenges, primarily because bone structures can obscure critical details necessary for accurate diagnosis. Recent advances in deep learning, particularly with diffusion models, offer significant promise for effectively minimizing the visibility of bone structures in CXR images, thereby improving clarity and diagnostic accuracy. Nevertheless, existing diffusion-based methods for bone suppression in CXR imaging struggle to balance the complete suppression of bones with preserving local texture details. Additionally, their high computational demand and extended processing time hinder their practical use in clinical settings. To address these limitations, we introduce a Global-Local Latent Consistency Model (GL-LCM) architecture. This model combines lung segmentation, dual-path sampling, and global-local fusion, enabling fast high-resolution bone suppression in CXR images. To tackle potential boundary artifacts and detail blurring in local-path sampling, we further propose Local-Enhanced Guidance, which addresses these issues without additional training. Comprehensive experiments on a self-collected dataset SZCH-X-Rays, and the public dataset JSRT, reveal that our GL-LCM delivers superior bone suppression and remarkable computational efficiency, significantly outperforming several competitive methods. Our code is available at https://github.com/diaoquesang/GL-LCM.

  • 10 authors
·
Aug 5, 2025

MIRAGE: Multi-scale Lesion-Informed Representation with Auxiliary Guidance for MRI Contrast Enhancement

Inferring contrast enhancement from one pre-contrast breast MRI slice is underdetermined: post-contrast appearance contains physiological information that is not uniquely encoded in baseline anatomy. Optimizing only paired pixel fidelity can suppress uncertain lesion enhancement, whereas adversarial or stochastic generative objectives can favor realistic post-contrast appearance without guaranteeing patient-specific lesion fidelity. We introduce MIRAGE, a residual 2D U-Net that combines global reconstruction and perceptual losses with three forms of lesion-aware supervision available only during training: an asymmetric penalty for missed tumor enhancement, multi-scale auxiliary tumor segmentation, and guidance through a frozen post-contrast tumor segmentation nnU-Net. We evaluate the method on 301 cases from the multi-centre MAMA-SYNTH data using eight complementary image-, region-, radiomics-, and segmentation-based metrics. MIRAGE ranks first on six metrics and markedly improves downstream lesion localization over tuned pix2pix, conditional diffusion, and latent bridge-matching baselines. The generative alternatives retain advantages in LPIPS or contrast classification, revealing a clear fidelity-utility trade-off. Leave-one-in and leave-one-out ablations show that the losses are partly redundant for lesion localization but exert distinct effects on appearance, radiomics, and boundary accuracy. These results support task-aware synthesis while also showing that its apparent optimality is conditional on the downstream models and metrics used to define utility.

  • 4 authors
·
Jul 20

The MAMA-MIA Challenge: Advancing Generalizability and Fairness in Breast MRI Tumor Segmentation and Treatment Response Prediction

Breast cancer is the most frequently diagnosed malignancy among women worldwide and a leading cause of cancer-related mortality. Dynamic contrast-enhanced magnetic resonance imaging plays a central role in tumor characterization and treatment monitoring, particularly in patients receiving neoadjuvant chemotherapy. However, existing artificial intelligence models for breast magnetic resonance imaging are typically developed and evaluated using heterogeneous datasets, study populations, and assessment protocols, making direct comparison difficult and limiting understanding of model robustness across institutions and clinically relevant patient subgroups. The MAMA-MIA Challenge was designed to address these challenges by providing a standardized benchmark for the joint evaluation of primary tumor segmentation and prediction of pathologic complete response using pre-treatment magnetic resonance imaging only. The training cohort comprised 1,506 patients from multiple institutions in the United States, while evaluation was conducted on an external test set of 574 patients from three independent European centers to assess cross-continental and cross-institutional generalization. A unified scoring framework combined predictive performance with subgroup consistency across age, menopausal status, and breast density. Twenty-six international teams participated in the final evaluation phase. Results demonstrate substantial performance variability under a common external evaluation framework and reveal trade-offs between overall accuracy and subgroup fairness. The challenge provides standardized datasets, evaluation protocols, and public resources to promote the development of robust and equitable artificial intelligence systems for breast cancer imaging.

  • 46 authors
·
Jun 18

Mediastinal lymph nodes segmentation using 3D convolutional neural network ensembles and anatomical priors guiding

As lung cancer evolves, the presence of enlarged and potentially malignant lymph nodes must be assessed to properly estimate disease progression and select the best treatment strategy. Following the clinical guidelines, estimation of short-axis diameter and mediastinum station are paramount for correct diagnosis. A method for accurate and automatic segmentation is hence decisive for quantitatively describing lymph nodes. In this study, the use of 3D convolutional neural networks, either through slab-wise schemes or the leveraging of downsampled entire volumes, is investigated. Furthermore, the potential impact from simple ensemble strategies is considered. As lymph nodes have similar attenuation values to nearby anatomical structures, we suggest using the knowledge of other organs as prior information to guide the segmentation task. To assess the segmentation and instance detection performances, a 5-fold cross-validation strategy was followed over a dataset of 120 contrast-enhanced CT volumes. For the 1178 lymph nodes with a short-axis diameter geq10 mm, our best performing approach reached a patient-wise recall of 92%, a false positive per patient ratio of 5, and a segmentation overlap of 80.5%. The method performs similarly well across all stations. Fusing a slab-wise and a full volume approach within an ensemble scheme generated the best performances. The anatomical priors guiding strategy is promising, yet a larger set than four organs appears needed to generate an optimal benefit. A larger dataset is also mandatory, given the wide range of expressions a lymph node can exhibit (i.e., shape, location, and attenuation), and contrast uptake variations.

  • 5 authors
·
Feb 11, 2021

MedCLIP-SAMv2: Towards Universal Text-Driven Medical Image Segmentation

Segmentation of anatomical structures and pathological regions in medical images is essential for modern clinical diagnosis, disease research, and treatment planning. While significant advancements have been made in deep learning-based segmentation techniques, many of these methods still suffer from limitations in data efficiency, generalizability, and interactivity. As a result, developing precise segmentation methods that require fewer labeled datasets remains a critical challenge in medical image analysis. Recently, the introduction of foundation models like CLIP and Segment-Anything-Model (SAM), with robust cross-domain representations, has paved the way for interactive and universal image segmentation. However, further exploration of these models for data-efficient segmentation in medical imaging is still needed and highly relevant. In this paper, we introduce MedCLIP-SAMv2, a novel framework that integrates the CLIP and SAM models to perform segmentation on clinical scans using text prompts, in both zero-shot and weakly supervised settings. Our approach includes fine-tuning the BiomedCLIP model with a new Decoupled Hard Negative Noise Contrastive Estimation (DHN-NCE) loss, and leveraging the Multi-modal Information Bottleneck (M2IB) to create visual prompts for generating segmentation masks from SAM in the zero-shot setting. We also investigate using zero-shot segmentation labels within a weakly supervised paradigm to enhance segmentation quality further. Extensive testing across four diverse segmentation tasks and medical imaging modalities (breast tumor ultrasound, brain tumor MRI, lung X-ray, and lung CT) demonstrates the high accuracy of our proposed framework. Our code is available at https://github.com/HealthX-Lab/MedCLIP-SAMv2.

  • 4 authors
·
Sep 28, 2024

pyMEAL: A Multi-Encoder Augmentation-Aware Learning for Robust and Generalizable Medical Image Translation

Medical imaging is critical for diagnostics, but clinical adoption of advanced AI-driven imaging faces challenges due to patient variability, image artifacts, and limited model generalization. While deep learning has transformed image analysis, 3D medical imaging still suffers from data scarcity and inconsistencies due to acquisition protocols, scanner differences, and patient motion. Traditional augmentation uses a single pipeline for all transformations, disregarding the unique traits of each augmentation and struggling with large data volumes. To address these challenges, we propose a Multi-encoder Augmentation-Aware Learning (MEAL) framework that leverages four distinct augmentation variants processed through dedicated encoders. Three fusion strategies such as concatenation (CC), fusion layer (FL), and adaptive controller block (BD) are integrated to build multi-encoder models that combine augmentation-specific features before decoding. MEAL-BD uniquely preserves augmentation-aware representations, enabling robust, protocol-invariant feature learning. As demonstrated in a Computed Tomography (CT)-to-T1-weighted Magnetic Resonance Imaging (MRI) translation study, MEAL-BD consistently achieved the best performance on both unseen- and predefined-test data. On both geometric transformations (like rotations and flips) and non-augmented inputs, MEAL-BD outperformed other competing methods, achieving higher mean peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM) scores. These results establish MEAL as a reliable framework for preserving structural fidelity and generalizing across clinically relevant variability. By reframing augmentation as a source of diverse, generalizable features, MEAL supports robust, protocol-invariant learning, advancing clinically reliable medical imaging solutions.

  • 6 authors
·
May 30, 2025

Towards a clinically accessible radiology foundation model: open-access and lightweight, with automated evaluation

The scaling laws and extraordinary performance of large foundation models motivate the development and utilization of such models in biomedicine. However, despite early promising results on some biomedical benchmarks, there are still major challenges that need to be addressed before these models can be used in real-world clinics. Frontier general-domain models such as GPT-4V still have significant performance gaps in multimodal biomedical applications. More importantly, less-acknowledged pragmatic issues, including accessibility, model cost, and tedious manual evaluation make it hard for clinicians to use state-of-the-art large models directly on private patient data. Here, we explore training open-source small multimodal models (SMMs) to bridge competency gaps for unmet clinical needs in radiology. To maximize data efficiency, we adopt a modular approach by incorporating state-of-the-art pre-trained models for image and text modalities, and focusing on training a lightweight adapter to ground each modality to the text embedding space, as exemplified by LLaVA-Med. For training, we assemble a large dataset of over 697 thousand radiology image-text pairs. For evaluation, we propose CheXprompt, a GPT-4-based metric for factuality evaluation, and demonstrate its parity with expert evaluation. For best practice, we conduct a systematic ablation study on various choices in data engineering and multimodal training. The resulting LlaVA-Rad (7B) model attains state-of-the-art results on standard radiology tasks such as report generation and cross-modal retrieval, even outperforming much larger models such as GPT-4V and Med-PaLM M (84B). The inference of LlaVA-Rad is fast and can be performed on a single V100 GPU in private settings, offering a promising state-of-the-art tool for real-world clinical applications.

  • 27 authors
·
Mar 12, 2024

MRI Super-Resolution with Deep Learning: A Comprehensive Survey

High-resolution (HR) magnetic resonance imaging (MRI) is crucial for many clinical and research applications. However, achieving it remains costly and constrained by technical trade-offs and experimental limitations. Super-resolution (SR) presents a promising computational approach to overcome these challenges by generating HR images from more affordable low-resolution (LR) scans, potentially improving diagnostic accuracy and efficiency without requiring additional hardware. This survey reviews recent advances in MRI SR techniques, with a focus on deep learning (DL) approaches. It examines DL-based MRI SR methods from the perspectives of computer vision, computational imaging, inverse problems, and MR physics, covering theoretical foundations, architectural designs, learning strategies, benchmark datasets, and performance metrics. We propose a systematic taxonomy to categorize these methods and present an in-depth study of both established and emerging SR techniques applicable to MRI, considering unique challenges in clinical and research contexts. We also highlight open challenges and directions that the community needs to address. Additionally, we provide a collection of essential open-access resources, tools, and tutorials, available on our GitHub: https://github.com/mkhateri/Awesome-MRI-Super-Resolution. IEEE keywords: MRI, Super-Resolution, Deep Learning, Computational Imaging, Inverse Problem, Survey.

Harvard Harvard University
·
Nov 20, 2025 2

SynthRAD2025 Grand Challenge dataset: generating synthetic CTs for radiotherapy

Medical imaging is essential in modern radiotherapy, supporting diagnosis, treatment planning, and monitoring. Synthetic imaging, particularly synthetic computed tomography (sCT), is gaining traction in radiotherapy. The SynthRAD2025 dataset and Grand Challenge promote advancements in sCT generation by providing a benchmarking platform for algorithms using cone-beam CT (CBCT) and magnetic resonance imaging (MRI). The dataset includes 2362 cases: 890 MRI-CT and 1472 CBCT-CT pairs from head-and-neck, thoracic, and abdominal cancer patients treated at five European university medical centers (UMC Groningen, UMC Utrecht, Radboud UMC, LMU University Hospital Munich, and University Hospital of Cologne). Data were acquired with diverse scanners and protocols. Pre-processing, including rigid and deformable image registration, ensures high-quality, modality-aligned images. Extensive quality assurance validates image consistency and usability. All imaging data is provided in MetaImage (.mha) format, ensuring compatibility with medical image processing tools. Metadata, including acquisition parameters and registration details, is available in structured CSV files. To maintain dataset integrity, SynthRAD2025 is divided into training (65%), validation (10%), and test (25%) sets. The dataset is accessible at https://doi.org/10.5281/zenodo.14918089 under the SynthRAD2025 collection. This dataset supports benchmarking and the development of synthetic imaging techniques for radiotherapy applications. Use cases include sCT generation for MRI-only and MR-guided photon/proton therapy, CBCT-based dose calculations, and adaptive radiotherapy workflows. By integrating diverse acquisition settings, SynthRAD2025 fosters robust, generalizable image synthesis algorithms, advancing personalized cancer care and adaptive radiotherapy.

  • 19 authors
·
Feb 24, 2025

Multi-view X-ray Image Synthesis with Multiple Domain Disentanglement from CT Scans

X-ray images play a vital role in the intraoperative processes due to their high resolution and fast imaging speed and greatly promote the subsequent segmentation, registration and reconstruction. However, over-dosed X-rays superimpose potential risks to human health to some extent. Data-driven algorithms from volume scans to X-ray images are restricted by the scarcity of paired X-ray and volume data. Existing methods are mainly realized by modelling the whole X-ray imaging procedure. In this study, we propose a learning-based approach termed CT2X-GAN to synthesize the X-ray images in an end-to-end manner using the content and style disentanglement from three different image domains. Our method decouples the anatomical structure information from CT scans and style information from unpaired real X-ray images/ digital reconstructed radiography (DRR) images via a series of decoupling encoders. Additionally, we introduce a novel consistency regularization term to improve the stylistic resemblance between synthesized X-ray images and real X-ray images. Meanwhile, we also impose a supervised process by computing the similarity of computed real DRR and synthesized DRR images. We further develop a pose attention module to fully strengthen the comprehensive information in the decoupled content code from CT scans, facilitating high-quality multi-view image synthesis in the lower 2D space. Extensive experiments were conducted on the publicly available CTSpine1K dataset and achieved 97.8350, 0.0842 and 3.0938 in terms of FID, KID and defined user-scored X-ray similarity, respectively. In comparison with 3D-aware methods (pi-GAN, EG3D), CT2X-GAN is superior in improving the synthesis quality and realistic to the real X-ray images.

  • 9 authors
·
Apr 18, 2024

A Comprehensive Study of GPT-4V's Multimodal Capabilities in Medical Imaging

This paper presents a comprehensive evaluation of GPT-4V's capabilities across diverse medical imaging tasks, including Radiology Report Generation, Medical Visual Question Answering (VQA), and Visual Grounding. While prior efforts have explored GPT-4V's performance in medical image analysis, to the best of our knowledge, our study represents the first quantitative evaluation on publicly available benchmarks. Our findings highlight GPT-4V's potential in generating descriptive reports for chest X-ray images, particularly when guided by well-structured prompts. Meanwhile, its performance on the MIMIC-CXR dataset benchmark reveals areas for improvement in certain evaluation metrics, such as CIDEr. In the domain of Medical VQA, GPT-4V demonstrates proficiency in distinguishing between question types but falls short of the VQA-RAD benchmark in terms of accuracy. Furthermore, our analysis finds the limitations of conventional evaluation metrics like the BLEU scores, advocating for the development of more semantically robust assessment methods. In the field of Visual Grounding, GPT-4V exhibits preliminary promise in recognizing bounding boxes, but its precision is lacking, especially in identifying specific medical organs and signs. Our evaluation underscores the significant potential of GPT-4V in the medical imaging domain, while also emphasizing the need for targeted refinements to fully unlock its capabilities.

  • 10 authors
·
Oct 31, 2023

CT-ΔBench: A Benchmark for Longitudinal 3D Medical Imaging Difference Reporting with Vision-Language Models

In medical imaging, the clinical value of Computed Tomography (CT) lies not only in depicting current disease status, but crucially in enabling longitudinal comparison of serial scans to determine disease evolution, a process that underpins response assessment, recurrence detection, and ongoing patient management. Yet, despite this central role of temporal comparison in clinical decision-making, existing medical foundation models remain largely confined to single-study understanding, leaving temporally grounded cross-examination insufficiently addressed. To address this gap, we study longitudinal imaging difference reporting, a task in which a model takes two temporally separated scans from the same patient and generates a clinically meaningful report describing interval changes between them. We introduce CT-ΔBench, a dedicated benchmark for this task with patient-level splitting to prevent information leakage. To better evaluate this task beyond surface-level text similarity, we further develop change-aware metrics specifically designed to capture clinically meaningful longitudinal changes, and conduct an independent physician validation to assess the reliability of the synthesized references and event extraction pipeline. We also compare direct paired-CT reasoning with an indirect two-stage pipeline that first generates single-timepoint reports and then performs textual differencing. Finally, we propose DeltaMed, a baseline model for direct paired-CT difference reporting, and train it on the benchmark training set. Together, these contributions lay the groundwork for temporally aware medical foundation models that better reflect real-world longitudinal clinical reasoning.

  • 4 authors
·
Aug 11

RISING a new framework for few-view tomographic image reconstruction with deep learning

This paper proposes a new two-step procedure for sparse-view tomographic image reconstruction. It is called RISING, since it combines an early-stopped Rapid Iterative Solver with a subsequent Iteration Network-based Gaining step. So far, regularized iterative methods have widely been used for X-ray computed tomography image reconstruction from low-sampled data, since they converge to a sparse solution in a suitable domain, as upheld by the Compressed Sensing theory. Unfortunately, their use is practically limited by their high computational cost which imposes to perform only a few iterations in the available time for clinical exams. Data-driven methods, using neural networks to post-process a coarse and noisy image obtained from geometrical algorithms, have been recently studied and appreciated for both their computational speed and accurate reconstructions. However, there is no evidence, neither theoretically nor numerically, that neural networks based algorithms solve the mathematical inverse problem modeling the tomographic reconstruction process. In our two-step approach, the first phase executes very few iterations of a regularized model-based algorithm whereas the second step completes the missing iterations by means of a neural network. The resulting hybrid deep-variational framework preserves the convergence properties of the iterative method and, at the same time, it exploits the computational speed and flexibility of a data-driven approach. Experiments performed on a simulated and a real data set confirm the numerical and visual accuracy of the reconstructed RISING images in short computational times.

  • 3 authors
·
Jan 24, 2022

Enhanced Contrastive Learning with Multi-view Longitudinal Data for Chest X-ray Report Generation

Automated radiology report generation offers an effective solution to alleviate radiologists' workload. However, most existing methods focus primarily on single or fixed-view images to model current disease conditions, which limits diagnostic accuracy and overlooks disease progression. Although some approaches utilize longitudinal data to track disease progression, they still rely on single images to analyze current visits. To address these issues, we propose enhanced contrastive learning with Multi-view Longitudinal data to facilitate chest X-ray Report Generation, named MLRG. Specifically, we introduce a multi-view longitudinal contrastive learning method that integrates spatial information from current multi-view images and temporal information from longitudinal data. This method also utilizes the inherent spatiotemporal information of radiology reports to supervise the pre-training of visual and textual representations. Subsequently, we present a tokenized absence encoding technique to flexibly handle missing patient-specific prior knowledge, allowing the model to produce more accurate radiology reports based on available prior knowledge. Extensive experiments on MIMIC-CXR, MIMIC-ABN, and Two-view CXR datasets demonstrate that our MLRG outperforms recent state-of-the-art methods, achieving a 2.3% BLEU-4 improvement on MIMIC-CXR, a 5.5% F1 score improvement on MIMIC-ABN, and a 2.7% F1 RadGraph improvement on Two-view CXR.

  • 7 authors
·
Feb 27, 2025

Using a 4-megapixel hybrid photon counting detector for fast, lab-based nanoscale x-ray tomography

Hybrid photon counting detectors (HPCDs) have unlocked new capabilities for x-ray-based measurements at synchrotrons around the world in the last 30 years. By leveraging independently optimized sensor and readout layers, they offer high quantum efficiency (> 80 %), ultra-low dark counts, sub-pixel point-spread function, and high count rates (> 10^{6} counts per pixel per second). Furthermore, their small pixel size and large active area endow them with excellent coverage and resolution for both real-space and reciprocal space imaging. Here, we demonstrate that HPCDs are also well-suited for laboratory-based nanoscale x-ray tomography (nano-xCT). We perform nano-xCT on an integrated circuit fabricated at the 130-nm node and produce a 3D reconstruction with 40 times more photons collected 20 times faster than in this group's previous work, for an overall speedup of 800times. We review the technical considerations of using an HPCD for tabletop tomography. We quantify our reconstruction image quality using well-established metrics, including the modulation transfer function (MTF), Fourier shell correlation (FSC), and contrast-to-noise (CNR), to validate our choice of experimental parameters that provide sufficient resolution and imaging speed. Using these metrics, we determine that even under current experimental conditions, 160 nm wiring features are reconstructed at 75-80 nm spatial resolution.

  • 11 authors
·
Feb 10

Vision-Language Models for Automated 3D PET/CT Report Generation

Positron emission tomography/computed tomography (PET/CT) is essential in oncology, yet the rapid expansion of scanners has outpaced the availability of trained specialists, making automated PET/CT report generation (PETRG) increasingly important for reducing clinical workload. Compared with structural imaging (e.g., X-ray, CT, and MRI), functional PET poses distinct challenges: metabolic patterns vary with tracer physiology, and whole-body 3D contextual information is required rather than local-region interpretation. To advance PETRG, we propose PETRG-3D, an end-to-end 3D dual-branch framework that separately encodes PET and CT volumes and incorporates style-adaptive prompts to mitigate inter-hospital variability in reporting practices. We construct PETRG-Lym, a multi-center lymphoma dataset collected from four hospitals (824 reports w/ 245,509 paired PET/CT slices), and construct AutoPET-RG-Lym, a publicly accessible PETRG benchmark derived from open imaging data but equipped with new expert-written, clinically validated reports (135 cases). To assess clinical utility, we introduce PETRG-Score, a lymphoma-specific evaluation protocol that jointly measures metabolic and structural findings across curated anatomical regions. Experiments show that PETRG-3D substantially outperforms existing methods on both natural language metrics (e.g., +31.49\% ROUGE-L) and clinical efficacy metrics (e.g., +8.18\% PET-All), highlighting the benefits of volumetric dual-modality modeling and style-aware prompting. Overall, this work establishes a foundation for future PET/CT-specific models emphasizing disease-aware reasoning and clinically reliable evaluation. Codes, models, and AutoPET-RG-Lym will be released.

  • 11 authors
·
Nov 24, 2025

MoSt-DSA: Modeling Motion and Structural Interactions for Direct Multi-Frame Interpolation in DSA Images

Artificial intelligence has become a crucial tool for medical image analysis. As an advanced cerebral angiography technique, Digital Subtraction Angiography (DSA) poses a challenge where the radiation dose to humans is proportional to the image count. By reducing images and using AI interpolation instead, the radiation can be cut significantly. However, DSA images present more complex motion and structural features than natural scenes, making interpolation more challenging. We propose MoSt-DSA, the first work that uses deep learning for DSA frame interpolation. Unlike natural scene Video Frame Interpolation (VFI) methods that extract unclear or coarse-grained features, we devise a general module that models motion and structural context interactions between frames in an efficient full convolution manner by adjusting optimal context range and transforming contexts into linear functions. Benefiting from this, MoSt-DSA is also the first method that directly achieves any number of interpolations at any time steps with just one forward pass during both training and testing. We conduct extensive comparisons with 7 representative VFI models for interpolating 1 to 3 frames, MoSt-DSA demonstrates robust results across 470 DSA image sequences (each typically 152 images), with average SSIM over 0.93, average PSNR over 38 (standard deviations of less than 0.030 and 3.6, respectively), comprehensively achieving state-of-the-art performance in accuracy, speed, visual effect, and memory usage. Our code is available at https://github.com/ZyoungXu/MoSt-DSA.

  • 6 authors
·
Jul 9, 2024

Asymmetric Paired-Annotation Learning for Multi-Structure ULF Pediatric Brain MRI Segmentation

Portable ultra-low-field (ULF) MRI can expand access to pediatric neuroimaging, but segmentation at 0.064 T remains challenging because anatomical boundaries are weakly delineated, small structures may be only partially visible, and high-field references can be locally misregistered. The LISA 2026 Challenge provides two non-equivalent annotations reflecting different sources of anatomical evidence: a highfield-derived (HF) mask defining the scored target and a low-field-edited (LF) mask aligned with visible ULF anatomy. In this challenge report, we describe AURA, an nnU-Net-based asymmetric supervision strategy that treats these annotations as distinct observations rather than interchangeable ground truths. AURA anchors training to the HF mask and incorporates the LF mask through a bounded reliability gate based on label disagreement, boundaries, predictive uncertainty, class reliability, and training stage. On a 16-case development split, the HF-supervised baseline, AURA, and their ensemble achieved Dice scores of 0.7984, 0.7950, and 0.7988, respectively, while the ensemble achieved an HD95 of 1.8892 and an ASSD of 0.7855. These results provide a preliminary evaluation of AURA within the LISA 2026 Challenge and motivate further assessment on the hidden test set and external ULF cohorts. Our code and pretrained models are available at https://github.com/minhdang050806/ A-nnU-Net-based-asymmetric-supervision-strategy.

  • 7 authors
·
Sep 1

Glance and Focus Reinforcement for Pan-cancer Screening

Pan-cancer screening in large-scale CT scans remains challenging for existing AI methods, primarily due to the difficulty of localizing diverse types of tiny lesions in large CT volumes. The extreme foreground-background imbalance significantly hinders models from focusing on diseased regions, while redundant focus on healthy regions not only decreases the efficiency but also increases false positives. Inspired by radiologists' glance and focus diagnostic strategy, we introduce GF-Screen, a Glance and Focus reinforcement learning framework for pan-cancer screening. GF-Screen employs a Glance model to localize the diseased regions and a Focus model to precisely segment the lesions, where segmentation results of the Focus model are leveraged to reward the Glance model via Reinforcement Learning (RL). Specifically, the Glance model crops a group of sub-volumes from the entire CT volume and learns to select the sub-volumes with lesions for the Focus model to segment. Given that the selecting operation is non-differentiable for segmentation training, we propose to employ the segmentation results to reward the Glance model. To optimize the Glance model, we introduce a novel group relative learning paradigm, which employs group relative comparison to prioritize high-advantage predictions and discard low-advantage predictions within sub-volume groups, not only improving efficiency but also reducing false positives. In this way, for the first time, we effectively extend cutting-edge RL techniques to tackle the specific challenges in pan-cancer screening. Extensive experiments on 16 internal and 7 external datasets across 9 lesion types demonstrated the effectiveness of GF-Screen. Notably, GF-Screen leads the public validation leaderboard of MICCAI FLARE25 pan-cancer challenge, surpassing the FLARE24 champion solution by a large margin (+25.6% DSC and +28.2% NSD).

Imaging foundation model for universal enhancement of non-ideal measurement CT

Non-ideal measurement computed tomography (NICT), which sacrifices optimal imaging standards for new advantages in CT imaging, is expanding the clinical application scope of CT images. However, with the reduction of imaging standards, the image quality has also been reduced, extremely limiting the clinical acceptability. Although numerous studies have demonstrated the feasibility of deep learning for the NICT enhancement in specific scenarios, their high data cost and limited generalizability have become large obstacles. The recent research on the foundation model has brought new opportunities for building a universal NICT enhancement model - bridging the image quality degradation with minimal data cost. However, owing to the challenges in the collection of large pre-training datasets and the compatibility of data variation, no success has been reported. In this paper, we propose a multi-scale integrated Transformer AMPlifier (TAMP), the first imaging foundation model for universal NICT enhancement. It has been pre-trained on a large-scale physical-driven simulation dataset with 3.6 million NICT-ICT image pairs, and is able to directly generalize to the NICT enhancement tasks with various non-ideal settings and body regions. Via the adaptation with few data, it can further achieve professional performance in real-world specific scenarios. Our extensive experiments have demonstrated that the proposed TAMP has significant potential for promoting the exploration and application of NICT and serving a wider range of medical scenarios.

  • 7 authors
·
Oct 2, 2024

ARC-CT: Anatomy-Routed Contrastive Vision-Language Learning for 3D Chest CT

Contrastive vision-language learning uses paired chest CT volumes and radiology reports to learn abnormality classifiers without manually annotated labels. However, two characteristics of chest CT challenge conventional global contrastive learning. First, many critical abnormalities are small or anatomically localized, and pooling an en- tire volume into a single embedding may dilute their visual evidence. Second, the standard contrastive objective treats every other scan in a batch as a negative. Because many chest CTs share abnormalities, this objective incorrectly pushes co-positive pairs apart. We propose Anatomy-Routed Contrastive Learning for 3D Chest CT (ARC-CT), a region-aware framework that addresses these limitations using only la- bels extracted from reports by an LLM, with no manual annotations or bounding boxes. ARC-CT combines three components: (1) an Anato- myQFormer localizing evidence via queries constrained by automatically generated organ masks; (2) a label-Jaccard soft InfoNCE objective in- tegrating the standard one-hot target with the label-set overlap of each pair, which reduces false-negative penalties between studies that share clinical findings; and (3) an organ-level alignment loss connecting mask- pooled visual features to organ-specific report text extracted offline with a large language model. ARC-CT achieves a 0.86 mask-free macro AUC across 18 abnormalities using a compact 3D ResNet-18 backbone. Over- all, ARC-CT outperforms both comparable efficient baselines and sev- eral larger transformer models. Our code and weights are available at https://github.com/arc-ct/arc-ct.

  • 4 authors
·
Aug 27

TrackRAD2025 challenge dataset: Real-time tumor tracking for MRI-guided radiotherapy

Purpose: Magnetic resonance imaging (MRI) to visualize anatomical motion is becoming increasingly important when treating cancer patients with radiotherapy. Hybrid MRI-linear accelerator (MRI-linac) systems allow real-time motion management during irradiation. This paper presents a multi-institutional real-time MRI time series dataset from different MRI-linac vendors. The dataset is designed to support developing and evaluating real-time tumor localization (tracking) algorithms for MRI-guided radiotherapy within the TrackRAD2025 challenge (https://trackrad2025.grand-challenge.org/). Acquisition and validation methods: The dataset consists of sagittal 2D cine MRIs in 585 patients from six centers (3 Dutch, 1 German, 1 Australian, and 1 Chinese). Tumors in the thorax, abdomen, and pelvis acquired on two commercially available MRI-linacs (0.35 T and 1.5 T) were included. For 108 cases, irradiation targets or tracking surrogates were manually segmented on each temporal frame. The dataset was randomly split into a public training set of 527 cases (477 unlabeled and 50 labeled) and a private testing set of 58 cases (all labeled). Data Format and Usage Notes: The data is publicly available under the TrackRAD2025 collection: https://doi.org/10.57967/hf/4539. Both the images and segmentations for each patient are available in metadata format. Potential Applications: This novel clinical dataset will enable the development and evaluation of real-time tumor localization algorithms for MRI-guided radiotherapy. By enabling more accurate motion management and adaptive treatment strategies, this dataset has the potential to advance the field of radiotherapy significantly.

  • 28 authors
·
Mar 24, 2025

UniPET: a universal network for high-quality PET image denoising across varied dose reduction factors

Most existing deep learning-based PET image denoising methods assume a fixed and known dose reduction factor (DRF) for low-dose PET images. However, these methods encounter significant performance degradation when the DRF varies beyond the assumed one in practical applications. To address the challenge posed by varied DRFs, several preliminary studies focus on the task of universal PET image denoising, aiming to train a universal model over low-dose data across DRFs. Nonetheless, these vanilla universal models often struggle with misaligned styles present in different DRF data, leading to the style elimination issue with a significant over-smoothing effect. To deal with this issue, we innovatively introduce domain generalization to PET image denoising and propose a universal PET image denoising network (UniPET) to achieve high-quality PET image denoising across diverse DRFs. UniPET comprises two primary innovations: a style alignment network (SAN) and a region-aware learning strategy (RALS). Specifically, SAN utilizes style alignment techniques derived from domain generalization to align and recover styles across different DRFs, ensuring the model's generalizability across various DRFs while effectively preserving styles. Furthermore, to enhance style recovery, RALS distinguishes between flat and stylized regions, exclusively conducting adversarial learning on the latter, thereby more effectively guiding the model's focus towards learning stylized regions. It is demonstrated that our proposed UniPET can adaptively recover different DRF styles and achieve high-quality PET image denoising across DRFs. Comprehensive experiments show that UniPET exhibits comparable performance to individual DRF-specific models at specific DRFs and realizes state-of-the-art performance in universal PET image denoising quantitatively, perceptually, and clinically.

  • 7 authors
·
Jun 8 3

Anatomy-Decomposed Chest Computed Tomography (CT) Projections as Scalable Supervision for Bone Suppression in Chest Radiographs

Bone overlap can obscure abnormalities in chest radiographs, while scarce paired training data limit supervised bone suppression. We address this challenge with a digitally reconstructed radiograph (DRR) framework that converts chest computed tomography (CT) into paired supervision for component suppression. A novel bone segmentation algorithm enables CT decomposition into bone, non-lung soft-tissue, and lung components, which are projected separately. Their weighted combination yields synthetic radiographs with pixel-registered component images that sum exactly to the full DRR. Models trained on these data suppress bone or lung components by predicting the target component and recovering the remainder by subtraction, transferring to real radiographs without real paired training data. As an extension, their outputs on real radiographs provide target domains for unpaired, component-wise DRR translation, reducing the appearance gap while retaining anatomical details. Across multiple public datasets, downstream detection experiments demonstrate the utility of bone suppression, with gains concentrated on abnormalities with substantial bone overlap. Compared with open-source DRR engines applied to the same CTs, our unmodified DRRs achieve comparable realism and preservation of label-relevant anatomy, while translated DRRs achieve the best Fréchet inception distance (FID), lung-field sharpness, and agreement with source-CT anatomy among the evaluated methods. Models and inference code: https://huggingface.co/qureaiorg/bone-suppression; Translated projections: https://huggingface.co/datasets/qureaiorg/ct2xr-projections.

  • 7 authors
·
Sep 20

The autoPET3 Challenge: Automated Lesion Segmentation in Whole-Body PET/CT x2013 Multitracer Multicenter Generalization

We report the design and results of the third autoPET challenge (MICCAI 2024), which benchmarked automated lesion segmentation in whole-body PET/CT under a compositional generalization setting. Training data comprised 1,014 [18F]-FDG PET/CT studies from the University Hospital Tübingen and 597 [18F]/[68Ga]-PSMA PET/CT studies from the LMU University Hospital Munich, constituting the largest publicly available annotated PSMA PET/CT dataset to date. The held-out test set of 200 studies covered four tracer-center combinations, two of which represented unseen compositional pairings. A complementary data-centric award category isolated the contribution of data handling strategies by restricting participants to a fixed baseline model. Seventeen teams submitted 27 algorithms, predominantly nnU-Net-based 3D networks with PET/CT channel concatenation. The top-ranked algorithm achieved a mean DSC of 0.66, FNV of 3.18 mL, and FPV of 2.78 mL across all four test conditions, improving DSC by 8% and reducing the false-negative volume by 5 mL relative to the provided baseline. Ranking was stable across bootstrap resampling and alternative ranking schemes for the top tier. Beyond the benchmark, we provide an in-depth analysis of segmentation performance at the patient and lesion level. Three main conclusions can be drawn: (1) in-domain multitracer PET/CT segmentation is sufficient and probably approaching reader agreement; (2) compositional generalization to unseen tracer-center combinations remains an open problem mainly driven by systematic volume overestimation; (3) heterogeneity and case difficulty drive performance variation substantially more than the choice of algorithm among top-ranked teams.

  • 30 authors
·
May 10

PET2Rep: Towards Vision-Language Model-Drived Automated Radiology Report Generation for Positron Emission Tomography

Positron emission tomography (PET) is a cornerstone of modern oncologic and neurologic imaging, distinguished by its unique ability to illuminate dynamic metabolic processes that transcend the anatomical focus of traditional imaging technologies. Radiology reports are essential for clinical decision making, yet their manual creation is labor-intensive and time-consuming. Recent advancements of vision-language models (VLMs) have shown strong potential in medical applications, presenting a promising avenue for automating report generation. However, existing applications of VLMs in the medical domain have predominantly focused on structural imaging modalities, while the unique characteristics of molecular PET imaging have largely been overlooked. To bridge the gap, we introduce PET2Rep, a large-scale comprehensive benchmark for evaluation of general and medical VLMs for radiology report generation for PET images. PET2Rep stands out as the first dedicated dataset for PET report generation with metabolic information, uniquely capturing whole-body image-report pairs that cover dozens of organs to fill the critical gap in existing benchmarks and mirror real-world clinical comprehensiveness. In addition to widely recognized natural language generation metrics, we introduce a series of clinical efficiency metrics to evaluate the quality of radiotracer uptake pattern description in key organs in generated reports. We conduct a head-to-head comparison of 30 cutting-edge general-purpose and medical-specialized VLMs. The results show that the current state-of-the-art VLMs perform poorly on PET report generation task, falling considerably short of fulfilling practical needs. Moreover, we identify several key insufficiency that need to be addressed to advance the development in medical applications.

  • 15 authors
·
Aug 5, 2025

Resolution-Agnostic Neural Operators for Multi-Rate Sparse-View CT

Sparse-view Computed Tomography (CT) reconstructs images from a limited number of X-ray projections to reduce radiation and scanning time, which is an ill-posed inverse problem. Existing methods achieve high-fidelity reconstructions but overfit to a fixed acquisition setup, failing to generalize well across sampling rates. For example, convolutional neural networks (CNNs) use the same kernels across resolutions, leading to artifacts when data resolution changes. This is a critical limitation in clinical practice, where acquisition sampling settings vary across organs and diagnostic protocols. We propose Computed Tomography neural Operator (CTO), the first neural operator (NO) framework for CT reconstruction. CTO extends learning from fixed discretized grids to continuous function space, enabling a single model to generalize across measurement sampling rates without retraining. We also propose new NO architectural designs for CT: (i) a dual-domain NO architecture in both sinogram and image spaces, capturing complementary spatial-frequency information, and (ii) rotation-equivariant DIScrete-COntinuous convolutions (DISCO) that exploit the rotational structure inherent in tomographic acquisition. Empirically, CTO outperforms CNNs (> 3.4dB PSNR gain) and other baselines in multi-resolution settings across multiple CT datasets. Compared to state-of-the-art diffusion methods, CTO has 500x faster inference with an average 3dB gain. CTO further demonstrates strong out-of-distribution robustness, maintaining gains under cross-dataset transfer and noisy sinogram conditions. Ablation studies also validate each design choice. CTO establishes neural operators as a principled and practical paradigm for flexible, discretization-agnostic CT reconstruction. Our code is available at https://github.com/neuraloperator/sparse_ct.

  • 4 authors
·
Aug 6

ChestX-ray8: Hospital-scale Chest X-ray Database and Benchmarks on Weakly-Supervised Classification and Localization of Common Thorax Diseases

The chest X-ray is one of the most commonly accessible radiological examinations for screening and diagnosis of many lung diseases. A tremendous number of X-ray imaging studies accompanied by radiological reports are accumulated and stored in many modern hospitals' Picture Archiving and Communication Systems (PACS). On the other side, it is still an open question how this type of hospital-size knowledge database containing invaluable imaging informatics (i.e., loosely labeled) can be used to facilitate the data-hungry deep learning paradigms in building truly large-scale high precision computer-aided diagnosis (CAD) systems. In this paper, we present a new chest X-ray database, namely "ChestX-ray8", which comprises 108,948 frontal-view X-ray images of 32,717 unique patients with the text-mined eight disease image labels (where each image can have multi-labels), from the associated radiological reports using natural language processing. Importantly, we demonstrate that these commonly occurring thoracic diseases can be detected and even spatially-located via a unified weakly-supervised multi-label image classification and disease localization framework, which is validated using our proposed dataset. Although the initial quantitative results are promising as reported, deep convolutional neural network based "reading chest X-rays" (i.e., recognizing and locating the common disease patterns trained with only image-level labels) remains a strenuous task for fully-automated high precision CAD systems. Data download link: https://nihcc.app.box.com/v/ChestXray-NIHCC

  • 6 authors
·
May 5, 2017 1

Multicentric thrombus segmentation using an attention-based recurrent network with gradual modality dropout

Detecting and delineating tiny targets in 3D brain scans is a central yet under-addressed challenge in medical imaging.In ischemic stroke, for instance, the culprit thrombus is small, low-contrast, and variably expressed across modalities(e.g., susceptibility-weighted T2 blooming, diffusion restriction on DWI/ADC), while real-world multi-center dataintroduce domain shifts, anisotropy, and frequent missing sequences. We introduce a methodology that couples an attention-based recurrent segmentation network (UpAttLLSTM), a training schedule that progressively increases the difficulty of hetero-modal learning, with gradual modality dropout, UpAttLLSTM aggregates context across slices via recurrent units (2.5D) and uses attention gates to fuse complementary cues across available sequences, making it robust to anisotropy and class imbalance. Gradual modality dropout systematically simulates site heterogeneity,noise, and missing modalities during training, acting as both augmentation and regularization to improve multi-center generalization. On a monocentric cohort, our approach detects thrombi in >90% of cases with a Dice score of 0.65. In a multi-center setting with missing modalities, it achieves-80% detection with a Dice score around 0.35. Beyond stroke, the proposed methodology directly transfers to other small-lesion tasks in 3D medical imaging where targets are scarce, subtle, and modality-dependent

  • 4 authors
·
Mar 31

Cross-modality (CT-MRI) prior augmented deep learning for robust lung tumor segmentation from small MR datasets

Lack of large expert annotated MR datasets makes training deep learning models difficult. Therefore, a cross-modality (MR-CT) deep learning segmentation approach that augments training data using pseudo MR images produced by transforming expert-segmented CT images was developed. Eighty-One T2-weighted MRI scans from 28 patients with non-small cell lung cancers were analyzed. Cross-modality prior encoding the transformation of CT to pseudo MR images resembling T2w MRI was learned as a generative adversarial deep learning model. This model augmented training data arising from 6 expert-segmented T2w MR patient scans with 377 pseudo MRI from non-small cell lung cancer CT patient scans with obtained from the Cancer Imaging Archive. A two-dimensional Unet implemented with batch normalization was trained to segment the tumors from T2w MRI. This method was benchmarked against (a) standard data augmentation and two state-of-the art cross-modality pseudo MR-based augmentation and (b) two segmentation networks. Segmentation accuracy was computed using Dice similarity coefficient (DSC), Hausdroff distance metrics, and volume ratio. The proposed approach produced the lowest statistical variability in the intensity distribution between pseudo and T2w MR images measured as Kullback-Leibler divergence of 0.069. This method produced the highest segmentation accuracy with a DSC of 0.75 and the lowest Hausdroff distance on the test dataset. This approach produced highly similar estimations of tumor growth as an expert (P = 0.37). A novel deep learning MR segmentation was developed that overcomes the limitation of learning robust models from small datasets by leveraging learned cross-modality priors to augment training. The results show the feasibility of the approach and the corresponding improvement over the state-of-the-art methods.

  • 7 authors
·
Jan 31, 2019

Comparing Conditional Diffusion Models for Synthesizing Contrast-Enhanced Breast MRI from Pre-Contrast Images

Dynamic contrast-enhanced (DCE) MRI is essential for breast cancer diagnosis and treatment. However, its reliance on contrast agents introduces safety concerns, contraindications, increased cost, and workflow complexity. To this end, we present pre-contrast conditioned denoising diffusion probabilistic models to synthesize DCE-MRI, introducing, evaluating, and comparing a total of 22 generative model variants in both single-breast and full breast settings. Towards enhancing lesion fidelity, we introduce both tumor-aware loss functions and explicit tumor segmentation mask conditioning. Using a public multicenter dataset and comparing to respective pre-contrast baselines, we observe that subtraction image-based models consistently outperform post-contrast-based models across five complementary evaluation metrics. Apart from assessing the entire image, we also separately evaluate the region of interest, where both tumor-aware losses and segmentation mask inputs improve evaluation metrics. The latter notably enhance qualitative results capturing contrast uptake, albeit assuming access to tumor localization inputs that are not guaranteed to be available in screening settings. A reader study involving 2 radiologists and 4 MRI technologists confirms the high realism of the synthetic images, indicating an emerging clinical potential of generative contrast-enhancement. We share our codebase at https://github.com/sebastibar/conditional-diffusion-breast-MRI.

  • 10 authors
·
Aug 19, 2025

ExposureDiffusion: Learning to Expose for Low-light Image Enhancement

Previous raw image-based low-light image enhancement methods predominantly relied on feed-forward neural networks to learn deterministic mappings from low-light to normally-exposed images. However, they failed to capture critical distribution information, leading to visually undesirable results. This work addresses the issue by seamlessly integrating a diffusion model with a physics-based exposure model. Different from a vanilla diffusion model that has to perform Gaussian denoising, with the injected physics-based exposure model, our restoration process can directly start from a noisy image instead of pure noise. As such, our method obtains significantly improved performance and reduced inference time compared with vanilla diffusion models. To make full use of the advantages of different intermediate steps, we further propose an adaptive residual layer that effectively screens out the side-effect in the iterative refinement when the intermediate results have been already well-exposed. The proposed framework can work with both real-paired datasets, SOTA noise models, and different backbone networks. Note that, the proposed framework is compatible with real-paired datasets, real/synthetic noise models, and different backbone networks. We evaluate the proposed method on various public benchmarks, achieving promising results with consistent improvements using different exposure models and backbones. Besides, the proposed method achieves better generalization capacity for unseen amplifying ratios and better performance than a larger feedforward neural model when few parameters are adopted.

  • 7 authors
·
Jul 15, 2023

Dia-LLaMA: Towards Large Language Model-driven CT Report Generation

Medical report generation has achieved remarkable advancements yet has still been faced with several challenges. First, the inherent imbalance in the distribution of normal and abnormal cases may lead models to exhibit a biased focus on normal samples, resulting in unreliable diagnoses. Second, the frequent occurrence of common template sentences in the reports may overwhelm the critical abnormal information. Moreover, existing works focus on 2D chest X-rays, leaving CT report generation underexplored due to the high-dimensional nature of CT images and the limited availability of CT-report pairs. Recently, LLM has shown a great ability to generate reliable answers with appropriate prompts, which shed light on addressing the aforementioned challenges. In this paper, we propose Dia-LLaMA, a framework to adapt the LLaMA2-7B for CT report generation by incorporating diagnostic information as guidance prompts. Considering the high dimension of CT, we leverage a pre-trained ViT3D with perceiver to extract the visual information. To tailor the LLM for report generation and emphasize abnormality, we extract additional diagnostic information by referring to a disease prototype memory bank, which is updated during training to capture common disease representations. Furthermore, we introduce disease-aware attention to enable the model to adjust attention for different diseases. Experiments on the chest CT dataset demonstrated that our proposed method outperformed previous methods and achieved state-of-the-art on both clinical efficacy performance and natural language generation metrics. The code will be made publically available.

  • 4 authors
·
Mar 24, 2024

Towards General Purpose Vision Foundation Models for Medical Image Analysis: An Experimental Study of DINOv2 on Radiology Benchmarks

The integration of deep learning systems into the medical domain has been hindered by the resource-intensive process of data annotation and the inability of these systems to generalize to different data distributions. Foundation models, which are models pre-trained on large datasets, have emerged as a solution to reduce reliance on annotated data and enhance model generalizability and robustness. DINOv2, an open-source foundation model pre-trained with self-supervised learning on 142 million curated natural images, excels in extracting general-purpose visual representations, exhibiting promising capabilities across various vision tasks. Nevertheless, a critical question remains unanswered regarding DINOv2's adaptability to radiological imaging, and the clarity on whether its features are sufficiently general to benefit radiology image analysis is yet to be established. Therefore, this study comprehensively evaluates DINOv2 for radiology, conducting over 100 experiments across diverse modalities (X-ray, CT, and MRI). Tasks include disease classification and organ segmentation on both 2D and 3D images, evaluated under different settings like kNN, few-shot learning, linear-probing, end-to-end fine-tuning, and parameter-efficient fine-tuning, to measure the effectiveness and generalizability of the DINOv2 feature embeddings. Comparative analyses with established medical image analysis models, U-Net and TransUnet for segmentation, and CNN and ViT models pre-trained via supervised, weakly supervised, and self-supervised learning for classification, reveal DINOv2's superior performance in segmentation tasks and competitive results in disease classification. The findings contribute insights to potential avenues for optimizing pre-training strategies for medical imaging and enhancing the broader understanding of DINOv2's role in bridging the gap between natural and radiological image analysis.

  • 6 authors
·
Dec 4, 2023

NeuroVLM-Bench: Evaluation of Vision-Enabled Large Language Models for Clinical Reasoning in Neurological Disorders

Recent advances in multimodal large language models enable new possibilities for image-based decision support. However, their reliability and operational trade-offs in neuroimaging remain insufficiently understood. We present a comprehensive benchmarking study of vision-enabled large language models for 2D neuroimaging using curated MRI and CT datasets covering multiple sclerosis, stroke, brain tumors, other abnormalities, and normal controls. Models are required to generate multiple outputs simultaneously, including diagnosis, diagnosis subtype, imaging modality, specialized sequence, and anatomical plane. Performance is evaluated across four directions: discriminative classification with abstention, calibration, structured-output validity, and computational efficiency. A multi-phase framework ensures fair comparison while controlling for selection bias. Across twenty frontier multimodal models, the results show that technical imaging attributes such as modality and plane are nearly solved, whereas diagnostic reasoning, especially subtype prediction, remains challenging. Tumor classification emerges as the most reliable task, stroke is moderately solvable, while multiple sclerosis and rare abnormalities remain difficult. Few-shot prompting improves performance for several models but increases token usage, latency, and cost. Gemini-2.5-Pro and GPT-5-Chat achieve the strongest overall diagnostic performance, while Gemini-2.5-Flash offers the best efficiency-performance trade-off. Among open-weight architectures, MedGemma-1.5-4B demonstrates the most promising results, as under few-shot prompting, it approaches the zero-shot performance of several proprietary models, while maintaining perfect structured output. These findings provide practical insights into performance, reliability, and efficiency trade-offs, supporting standardized evaluation of multimodal LLMs in neuroimaging.

  • 8 authors
·
Mar 24

Large-scale and Fine-grained Vision-language Pre-training for Enhanced CT Image Understanding

Artificial intelligence (AI) shows great potential in assisting radiologists to improve the efficiency and accuracy of medical image interpretation and diagnosis. However, a versatile AI model requires large-scale data and comprehensive annotations, which are often impractical in medical settings. Recent studies leverage radiology reports as a naturally high-quality supervision for medical images, using contrastive language-image pre-training (CLIP) to develop language-informed models for radiological image interpretation. Nonetheless, these approaches typically contrast entire images with reports, neglecting the local associations between imaging regions and report sentences, which may undermine model performance and interoperability. In this paper, we propose a fine-grained vision-language model (fVLM) for anatomy-level CT image interpretation. Specifically, we explicitly match anatomical regions of CT images with corresponding descriptions in radiology reports and perform contrastive pre-training for each anatomy individually. Fine-grained alignment, however, faces considerable false-negative challenges, mainly from the abundance of anatomy-level healthy samples and similarly diseased abnormalities. To tackle this issue, we propose identifying false negatives of both normal and abnormal samples and calibrating contrastive learning from patient-level to disease-aware pairing. We curated the largest CT dataset to date, comprising imaging and report data from 69,086 patients, and conducted a comprehensive evaluation of 54 major and important disease diagnosis tasks across 15 main anatomies. Experimental results demonstrate the substantial potential of fVLM in versatile medical image interpretation. In the zero-shot classification task, we achieved an average AUC of 81.3% on 54 diagnosis tasks, surpassing CLIP and supervised methods by 12.9% and 8.0%, respectively.

  • 11 authors
·
Jan 23, 2025

XGLASS: X-Ray, Gaze and Language Assisted Slice Sequencing for CT Volumes

Vision-language models (VLMs) achieve remarkable performance on 2D medical images, such as X-rays or pathology images, while 3D VLMs that directly process CT/MRI volumes lag behind due to limited 3D training data and the predominance of 2D foundation architectures. To leverage powerful 2D VLMs for analyzing medical volumes, which contain hundreds of slices, it is therefore necessary to focus only on those few slices, which are diagnostically relevant. To enable such a prioritization, we propose XGLASS, a method that transfers medical expertise from 2D X-rays to 3D CT for task-aware slice prioritization. XGLASS uses disease-conditioned importance maps derived from language-aligned radiologist gaze on X-rays and spatially aligns them with coronal CT projections, bringing gaze priors and CT content into a shared 2D representation. The fused gaze-prior/CT projection is then used to predict a disease-specific ordering of axial slices, prioritizing diagnostically relevant slices. XGLASS significantly improves budgeted retrieval over 2D and 3D-native baselines, achieving a top-10 hit rate up to 75.9% for the best-performing disease. In practice, this means that after inspecting only the top 10 slices (4.17% of a 240-slice scan), XGLASS identifies a diagnostically relevant slice in more than 75% of cases. For downstream slice-wise finding classification, an XGLASS-selected 30-slice candidate set reduces model calls by 87.5% while improving F1 by 11.3 percentage points over all-slice inference, 4.2 points over the strongest 2D selector, and remains competitive with 3D-native selectors while requiring up to 130.8 times less time and 10.9 times less GPU memory per finding, supporting its use as a lightweight preselector for volumetric CT analysis. The code and pretrained checkpoint are available on https://github.com/michaelgloeckler/XGLASS.

  • 2 authors
·
Oct 18

Prediction of the motion of chest internal points using a recurrent neural network trained with real-time recurrent learning for latency compensation in lung cancer radiotherapy

During the radiotherapy treatment of patients with lung cancer, the radiation delivered to healthy tissue around the tumor needs to be minimized, which is difficult because of respiratory motion and the latency of linear accelerator systems. In the proposed study, we first use the Lucas-Kanade pyramidal optical flow algorithm to perform deformable image registration of chest computed tomography scan images of four patients with lung cancer. We then track three internal points close to the lung tumor based on the previously computed deformation field and predict their position with a recurrent neural network (RNN) trained using real-time recurrent learning (RTRL) and gradient clipping. The breathing data is quite regular, sampled at approximately 2.5Hz, and includes artificial drift in the spine direction. The amplitude of the motion of the tracked points ranged from 12.0mm to 22.7mm. Finally, we propose a simple method for recovering and predicting 3D tumor images from the tracked points and the initial tumor image based on a linear correspondence model and Nadaraya-Watson non-linear regression. The root-mean-square error, maximum error, and jitter corresponding to the RNN prediction on the test set were smaller than the same performance measures obtained with linear prediction and least mean squares (LMS). In particular, the maximum prediction error associated with the RNN, equal to 1.51mm, is respectively 16.1% and 5.0% lower than the maximum error associated with linear prediction and LMS. The average prediction time per time step with RTRL is equal to 119ms, which is less than the 400ms marker position sampling time. The tumor position in the predicted images appears visually correct, which is confirmed by the high mean cross-correlation between the original and predicted images, equal to 0.955.

  • 4 authors
·
Jul 13, 2022

IMPACT: A Generic Semantic Loss for Multimodal Medical Image Registration

Image registration is fundamental in medical imaging, enabling precise alignment of anatomical structures for diagnosis, treatment planning, image-guided treatment or longitudinal monitoring. This work introduces IMPACT (Image Metric with Pretrained model-Agnostic Comparison for Transmodality registration), a generic semantic similarity metric designed for seamless integration into diverse image registration frameworks (such as Elastix and Voxelmorph). It compares deep learning-based features extracted from medical images without requiring task-specific training, ensuring broad applicability across various modalities. By leveraging the features of the large-scale pretrained TotalSegmentator models and the ability to integrate Segment Anything Model (SAM) and other large-scale segmentation networks, this approach offers significant advantages. It provides robust, scalable, and efficient solutions for multimodal image registration. The IMPACT loss was evaluated on five challenging registration tasks involving thoracic CT/CBCT, and pelvic MR/CT datasets. Quantitative metrics, such as Target Registration Error and Dice Similarity Coefficient, demonstrated significant improvements in anatomical alignment compared to baseline methods. Qualitative analyses further confirmed the increased robustness of the proposed metric in the face of noise, artifacts, and modality variations. IMPACT's versatility and efficiency make it a valuable tool for advancing registration performance in clinical and research applications, addressing critical challenges in multimodal medical imaging.

  • 8 authors
·
Mar 31, 2025

Benchmarking Foundation and Large Language Models for Few-Shot Medical Image Segmentation

Few-shot medical image segmentation (FS-MIS) aims to segment novel regions of interest (ROIs) from a few annotated support examples. Despite rapid progress, existing FS-MIS solutions span diverse paradigms but are evaluated under inconsistent settings, leaving their relative effectiveness unclear. We introduce FAME, a unified benchmark for evaluating FS-MIS solutions, covering specialists, SAM-based methods, CLIP-based methods, and MLLM-based methods. FAME contains 14,958 test samples across 7 anatomical sites, 9 imaging modalities, and 14 ROI categories, and evaluates models under zero-shot and ten-shot settings with additional assessment of target-absence recognition and generalization under covariate and semantic shifts. Our evaluation reveals several findings. First, effective few-shot segmentation depends on how models exploit support examples: direct visual adaptation generally outperforms prompt-based strategies. Second, increasing support examples improves performance only when models can effectively utilize them. Third, semantic transfer remains substantially more challenging than imaging-domain adaptation, and strong localization ability does not necessarily imply reliable target-absence recognition. We hope FAME provides a comprehensive understanding of current FS-MIS solutions and facilitates the development of more effective and reliable few-shot medical segmentation methods.

  • 5 authors
·
Jul 29

Application of NotebookLM, a Large Language Model with Retrieval-Augmented Generation, for Lung Cancer Staging

Purpose: In radiology, large language models (LLMs), including ChatGPT, have recently gained attention, and their utility is being rapidly evaluated. However, concerns have emerged regarding their reliability in clinical applications due to limitations such as hallucinations and insufficient referencing. To address these issues, we focus on the latest technology, retrieval-augmented generation (RAG), which enables LLMs to reference reliable external knowledge (REK). Specifically, this study examines the utility and reliability of a recently released RAG-equipped LLM (RAG-LLM), NotebookLM, for staging lung cancer. Materials and methods: We summarized the current lung cancer staging guideline in Japan and provided this as REK to NotebookLM. We then tasked NotebookLM with staging 100 fictional lung cancer cases based on CT findings and evaluated its accuracy. For comparison, we performed the same task using a gold-standard LLM, GPT-4 Omni (GPT-4o), both with and without the REK. Results: NotebookLM achieved 86% diagnostic accuracy in the lung cancer staging experiment, outperforming GPT-4o, which recorded 39% accuracy with the REK and 25% without it. Moreover, NotebookLM demonstrated 95% accuracy in searching reference locations within the REK. Conclusion: NotebookLM successfully performed lung cancer staging by utilizing the REK, demonstrating superior performance compared to GPT-4o. Additionally, it provided highly accurate reference locations within the REK, allowing radiologists to efficiently evaluate the reliability of NotebookLM's responses and detect possible hallucinations. Overall, this study highlights the potential of NotebookLM, a RAG-LLM, in image diagnosis.

  • 8 authors
·
Oct 8, 2024

Experimental Design for Multi-Channel Imaging via Task-Driven Feature Selection

This paper presents a data-driven, task-specific paradigm for experimental design, to shorten acquisition time, reduce costs, and accelerate the deployment of imaging devices. Current approaches in experimental design focus on model-parameter estimation and require specification of a particular model, whereas in imaging, other tasks may drive the design. Furthermore, such approaches often lead to intractable optimization problems in real-world imaging applications. Here we present a new paradigm for experimental design that simultaneously optimizes the design (set of image channels) and trains a machine-learning model to execute a user-specified image-analysis task. The approach obtains data densely-sampled over the measurement space (many image channels) for a small number of acquisitions, then identifies a subset of channels of prespecified size that best supports the task. We propose a method: TADRED for TAsk-DRiven Experimental Design in imaging, to identify the most informative channel-subset whilst simultaneously training a network to execute the task given the subset. Experiments demonstrate the potential of TADRED in diverse imaging applications: several clinically-relevant tasks in magnetic resonance imaging; and remote sensing and physiological applications of hyperspectral imaging. Results show substantial improvement over classical experimental design, two recent application-specific methods within the new paradigm, and state-of-the-art approaches in supervised feature selection. We anticipate further applications of our approach. Code is available: https://github.com/sbb-gh/experimental-design-multichannel

  • 3 authors
·
Oct 13, 2022

MedCLIP-SAM: Bridging Text and Image Towards Universal Medical Image Segmentation

Medical image segmentation of anatomical structures and pathology is crucial in modern clinical diagnosis, disease study, and treatment planning. To date, great progress has been made in deep learning-based segmentation techniques, but most methods still lack data efficiency, generalizability, and interactability. Consequently, the development of new, precise segmentation methods that demand fewer labeled datasets is of utmost importance in medical image analysis. Recently, the emergence of foundation models, such as CLIP and Segment-Anything-Model (SAM), with comprehensive cross-domain representation opened the door for interactive and universal image segmentation. However, exploration of these models for data-efficient medical image segmentation is still limited, but is highly necessary. In this paper, we propose a novel framework, called MedCLIP-SAM that combines CLIP and SAM models to generate segmentation of clinical scans using text prompts in both zero-shot and weakly supervised settings. To achieve this, we employed a new Decoupled Hard Negative Noise Contrastive Estimation (DHN-NCE) loss to fine-tune the BiomedCLIP model and the recent gScoreCAM to generate prompts to obtain segmentation masks from SAM in a zero-shot setting. Additionally, we explored the use of zero-shot segmentation labels in a weakly supervised paradigm to improve the segmentation quality further. By extensively testing three diverse segmentation tasks and medical image modalities (breast tumor ultrasound, brain tumor MRI, and lung X-ray), our proposed framework has demonstrated excellent accuracy. Code is available at https://github.com/HealthX-Lab/MedCLIP-SAM.

  • 4 authors
·
Mar 29, 2024

Weakly Supervised Pneumonia Localization from Chest X-Rays Using Deep Neural Network and Grad-CAM Explanations

Chest X-ray imaging is commonly used to diagnose pneumonia, but accurately localizing the pneumonia-affected regions typically requires detailed pixel-level annotations, which are costly and time consuming to obtain. To address this limitation, this study proposes a weakly supervised deep learning framework for pneumonia classification and localization using Gradient-weighted Class Activation Mapping (Grad-CAM). Instead of relying on costly pixel-level annotations, the proposed method utilizes image-level labels to generate clinically meaningful heatmaps that highlight pneumonia-affected regions. Furthermore, we evaluate seven pre-trained deep learning models, including a Vision Transformer, under identical training conditions, using focal loss and patient-wise splits to prevent data leakage. Experimental results suggest that all models achieved high classification accuracy (96--98\%), with ResNet-18 and EfficientNet-B0 showing the best overall performance and MobileNet-V3 providing an efficient lightweight alternative. Grad-CAM heatmap visualizations confirm that the proposed methods focus on clinically relevant lung regions, supporting the use of explainable AI for radiological diagnostics. Overall, this work highlights the potential of weakly supervised, explainable models that enhance transparency and clinical trust in AI-assisted pneumonia screening.

  • 2 authors
·
Nov 1, 2025

Dataset and Benchmark for Enhancing Critical Retained Foreign Object Detection

Critical retained foreign objects (RFOs), including surgical instruments like sponges and needles, pose serious patient safety risks and carry significant financial and legal implications for healthcare institutions. Detecting critical RFOs using artificial intelligence remains challenging due to their rarity and the limited availability of chest X-ray datasets that specifically feature critical RFOs cases. Existing datasets only contain non-critical RFOs, like necklace or zipper, further limiting their utility for developing clinically impactful detection algorithms. To address these limitations, we introduce "Hopkins RFOs Bench", the first and largest dataset of its kind, containing 144 chest X-ray images of critical RFO cases collected over 18 years from the Johns Hopkins Health System. Using this dataset, we benchmark several state-of-the-art object detection models, highlighting the need for enhanced detection methodologies for critical RFO cases. Recognizing data scarcity challenges, we further explore image synthetic methods to bridge this gap. We evaluate two advanced synthetic image methods, DeepDRR-RFO, a physics-based method, and RoentGen-RFO, a diffusion-based method, for creating realistic radiographs featuring critical RFOs. Our comprehensive analysis identifies the strengths and limitations of each synthetic method, providing insights into effectively utilizing synthetic data to enhance model training. The Hopkins RFOs Bench and our findings significantly advance the development of reliable, generalizable AI-driven solutions for detecting critical RFOs in clinical chest X-rays.

  • 16 authors
·
Jul 9, 2025

Site-Level Fine-Tuning with Progressive Layer Freezing: Towards Robust Prediction of Bronchopulmonary Dysplasia from Day-1 Chest Radiographs in Extremely Preterm Infants

Bronchopulmonary dysplasia (BPD) is a chronic lung disease affecting 35% of extremely low birth weight infants. Defined by oxygen dependence at 36 weeks postmenstrual age, it causes lifelong respiratory complications. However, preventive interventions carry severe risks, including neurodevelopmental impairment, ventilator-induced lung injury, and systemic complications. Therefore, early BPD prognosis and prediction of BPD outcome is crucial to avoid unnecessary toxicity in low risk infants. Admission radiographs of extremely preterm infants are routinely acquired within 24h of life and could serve as a non-invasive prognostic tool. In this work, we developed and investigated a deep learning approach using chest X-rays from 163 extremely low-birth-weight infants (leq32 weeks gestation, 401-999g) obtained within 24 hours of birth. We fine-tuned a ResNet-50 pretrained specifically on adult chest radiographs, employing progressive layer freezing with discriminative learning rates to prevent overfitting and evaluated a CutMix augmentation and linear probing. For moderate/severe BPD outcome prediction, our best performing model with progressive freezing, linear probing and CutMix achieved an AUROC of 0.78 pm 0.10, balanced accuracy of 0.69 pm 0.10, and an F1-score of 0.67 pm 0.11. In-domain pre-training significantly outperformed ImageNet initialization (p = 0.031) which confirms domain-specific pretraining to be important for BPD outcome prediction. Routine IRDS grades showed limited prognostic value (AUROC 0.57 pm 0.11), confirming the need of learned markers. Our approach demonstrates that domain-specific pretraining enables accurate BPD prediction from routine day-1 radiographs. Through progressive freezing and linear probing, the method remains computationally feasible for site-level implementation and future federated learning deployments.

  • 16 authors
·
Jul 16, 2025

Prompt as Knowledge Bank: Boost Vision-language model via Structural Representation for zero-shot medical detection

Zero-shot medical detection can further improve detection performance without relying on annotated medical images even upon the fine-tuned model, showing great clinical value. Recent studies leverage grounded vision-language models (GLIP) to achieve this by using detailed disease descriptions as prompts for the target disease name during the inference phase. However, these methods typically treat prompts as equivalent context to the target name, making it difficult to assign specific disease knowledge based on visual information, leading to a coarse alignment between images and target descriptions. In this paper, we propose StructuralGLIP, which introduces an auxiliary branch to encode prompts into a latent knowledge bank layer-by-layer, enabling more context-aware and fine-grained alignment. Specifically, in each layer, we select highly similar features from both the image representation and the knowledge bank, forming structural representations that capture nuanced relationships between image patches and target descriptions. These features are then fused across modalities to further enhance detection performance. Extensive experiments demonstrate that StructuralGLIP achieves a +4.1\% AP improvement over prior state-of-the-art methods across seven zero-shot medical detection benchmarks, and consistently improves fine-tuned models by +3.2\% AP on endoscopy image datasets.

  • 8 authors
·
Feb 22, 2025