new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Oct 7

Scaling Laws for Energy Efficiency of Local LLMs

Deploying local large language models and vision-language models on edge devices requires balancing accuracy with constrained computational and energy budgets. Although graphics processors dominate modern artificial-intelligence deployment, most consumer hardware--including laptops, desktops, industrial controllers, and embedded systems--relies on central processing units. Despite this, the computational laws governing central-processing-unit-only inference for local language and vision-language workloads remain largely unexplored. We systematically benchmark large language and vision-language models on two representative central-processing-unit tiers widely used for local inference: a MacBook Pro M2, reflecting mainstream laptop-class deployment, and a Raspberry Pi 5, representing constrained, low-power embedded settings. Using a unified methodology based on continuous sampling of processor and memory usage together with area-under-curve integration, we characterize how computational load scales with input text length for language models and with image resolution for vision-language models. We uncover two empirical scaling laws: (1) computational cost for language-model inference scales approximately linearly with token length; and (2) vision-language models exhibit a preprocessing-driven "resolution knee", where compute remains constant above an internal resolution clamp and decreases sharply below it. Beyond these laws, we show that quantum-inspired compression reduces processor and memory usage by up to 71.9% and energy consumption by up to 62%, while preserving or improving semantic accuracy. These results provide a systematic quantification of multimodal central-processing-unit-only scaling for local language and vision-language workloads, and they identify model compression and input-resolution preprocessing as effective, low-cost levers for sustainable edge inference.

MultiverseComputingCAI Multiverse Computing
·
Dec 28, 2025

Domain-Specific Latent Representations Improve the Fidelity of Diffusion-Based Medical Image Super-Resolution

Latent diffusion models for medical image super-resolution universally inherit variational autoencoders designed for natural photographs. We show that this default choice, not the diffusion architecture, is the dominant constraint on reconstruction quality. In a controlled experiment holding all other pipeline components fixed, replacing the generic Stable Diffusion VAE with MedVAE, a domain-specific autoencoder pretrained on more than 1.6 million medical images, yields +2.91 to +3.29 dB PSNR improvement across knee MRI, brain MRI, and chest X-ray (n = 1,820; Cohen's d = 1.37 to 1.86, all p < 10^{-20}, Wilcoxon signed-rank). Wavelet decomposition localises the advantage to the finest spatial frequency bands encoding anatomically relevant fine structure. Ablations across inference schedules, prediction targets, and generative architectures confirm the gap is stable within plus or minus 0.15 dB, while hallucination rates remain comparable between methods (Cohen's h < 0.02 across all datasets), establishing that reconstruction fidelity and generative hallucination are governed by independent pipeline components. These results provide a practical screening criterion: autoencoder reconstruction quality, measurable without diffusion training, predicts downstream SR performance (R^2 = 0.67), suggesting that domain-specific VAE selection should precede diffusion architecture search. Code and trained model weights are publicly available at https://github.com/sebasmos/latent-sr.

MITCriticalData Global
·
Apr 13 2

Active Sensing of Knee Osteoarthritis Progression with Reinforcement Learning

Osteoarthritis (OA) is the most common musculoskeletal disease, which has no cure. Knee OA (KOA) is one of the highest causes of disability worldwide, and it costs billions of United States dollars to the global community. Prediction of KOA progression has been of high interest to the community for years, as it can advance treatment development through more efficient clinical trials and improve patient outcomes through more efficient healthcare utilization. Existing approaches for predicting KOA, however, are predominantly static, i.e. consider data from a single time point to predict progression many years into the future, and knee level, i.e. consider progression in a single joint only. Due to these and related reasons, these methods fail to deliver the level of predictive performance, which is sufficient to result in cost savings and better patient outcomes. Collecting extensive data from all patients on a regular basis could address the issue, but it is limited by the high cost at a population level. In this work, we propose to go beyond static prediction models in OA, and bring a novel Active Sensing (AS) approach, designed to dynamically follow up patients with the objective of maximizing the number of informative data acquisitions, while minimizing their total cost over a period of time. Our approach is based on Reinforcement Learning (RL), and it leverages a novel reward function designed specifically for AS of disease progression in more than one part of a human body. Our method is end-to-end, relies on multi-modal Deep Learning, and requires no human input at inference time. Throughout an exhaustive experimental evaluation, we show that using RL can provide a higher monetary benefit when compared to state-of-the-art baselines.

  • 4 authors
·
Aug 5, 2024

Semixup: In- and Out-of-Manifold Regularization for Deep Semi-Supervised Knee Osteoarthritis Severity Grading from Plain Radiographs

Knee osteoarthritis (OA) is one of the highest disability factors in the world. This musculoskeletal disorder is assessed from clinical symptoms, and typically confirmed via radiographic assessment. This visual assessment done by a radiologist requires experience, and suffers from moderate to high inter-observer variability. The recent literature has shown that deep learning methods can reliably perform the OA severity assessment according to the gold standard Kellgren-Lawrence (KL) grading system. However, these methods require large amounts of labeled data, which are costly to obtain. In this study, we propose the Semixup algorithm, a semi-supervised learning (SSL) approach to leverage unlabeled data. Semixup relies on consistency regularization using in- and out-of-manifold samples, together with interpolated consistency. On an independent test set, our method significantly outperformed other state-of-the-art SSL methods in most cases. Finally, when compared to a well-tuned fully supervised baseline that yielded a balanced accuracy (BA) of 70.9pm0.8% on the test set, Semixup had comparable performance -- BA of 71pm0.8% (p=0.368) while requiring 6 times less labeled data. These results show that our proposed SSL method allows building fully automatic OA severity assessment tools with datasets that are available outside research settings.

  • 4 authors
·
Mar 4, 2020

End-To-End Prediction of Knee Osteoarthritis Progression With Multi-Modal Transformers

Knee Osteoarthritis (KOA) is a highly prevalent chronic musculoskeletal condition with no currently available treatment. The manifestation of KOA is heterogeneous and prediction of its progression is challenging. Current literature suggests that the use of multi-modal data and advanced modeling methods, such as the ones based on Deep Learning, has promise in tackling this challenge. To date, however, the evidence on the efficacy of this approach is limited. In this study, we leveraged recent advances in Deep Learning and, using a Transformer approach, developed a unified framework for the multi-modal fusion of knee imaging data. Subsequently, we analyzed its performance across a range of scenarios by investigating multiple progression horizons -- from short-term to long-term. We report our findings using a large cohort (n=2421-3967) derived from the Osteoarthritis Initiative dataset. We show that structural knee MRI allows identifying radiographic KOA progressors on par with multi-modal fusion approaches, achieving an area under the ROC curve (ROC AUC) of 0.70-0.76 and Average Precision (AP) of 0.15-0.54 in 2-8 year horizons. Progression within 1 year was better predicted with a multi-modal method using X-ray, structural, and compositional MR images -- ROC AUC of 0.76(0.04), AP of 0.13(0.04) -- or via clinical data. Our follow-up analysis generally shows that prediction from the imaging data is more accurate for post-traumatic subjects, and we further investigate which subject subgroups may benefit the most. The present study provides novel insights into multi-modal imaging of KOA and brings a unified data-driven framework for studying its progression in an end-to-end manner, providing new tools for the design of more efficient clinical trials. The source code of our framework and the pre-trained models are made publicly available.

  • 4 authors
·
Jul 3, 2023