new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Nov 24

BS-Diff: Effective Bone Suppression Using Conditional Diffusion Models from Chest X-Ray Images

Chest X-rays (CXRs) are commonly utilized as a low-dose modality for lung screening. Nonetheless, the efficacy of CXRs is somewhat impeded, given that approximately 75% of the lung area overlaps with bone, which in turn hampers the detection and diagnosis of diseases. As a remedial measure, bone suppression techniques have been introduced. The current dual-energy subtraction imaging technique in the clinic requires costly equipment and subjects being exposed to high radiation. To circumvent these issues, deep learning-based image generation algorithms have been proposed. However, existing methods fall short in terms of producing high-quality images and capturing texture details, particularly with pulmonary vessels. To address these issues, this paper proposes a new bone suppression framework, termed BS-Diff, that comprises a conditional diffusion model equipped with a U-Net architecture and a simple enhancement module to incorporate an autoencoder. Our proposed network cannot only generate soft tissue images with a high bone suppression rate but also possesses the capability to capture fine image details. Additionally, we compiled the largest dataset since 2010, including data from 120 patients with high-definition, high-resolution paired CXRs and soft tissue images collected by our affiliated hospital. Extensive experiments, comparative analyses, ablation studies, and clinical evaluations indicate that the proposed BS-Diff outperforms several bone-suppression models across multiple metrics. Our code can be accessed at https://github.com/Benny0323/BS-Diff.

  • 11 authors
·
Nov 26, 2023

RadVLM: A Multitask Conversational Vision-Language Model for Radiology

The widespread use of chest X-rays (CXRs), coupled with a shortage of radiologists, has driven growing interest in automated CXR analysis and AI-assisted reporting. While existing vision-language models (VLMs) show promise in specific tasks such as report generation or abnormality detection, they often lack support for interactive diagnostic capabilities. In this work we present RadVLM, a compact, multitask conversational foundation model designed for CXR interpretation. To this end, we curate a large-scale instruction dataset comprising over 1 million image-instruction pairs containing both single-turn tasks -- such as report generation, abnormality classification, and visual grounding -- and multi-turn, multi-task conversational interactions. After fine-tuning RadVLM on this instruction dataset, we evaluate it across different tasks along with re-implemented baseline VLMs. Our results show that RadVLM achieves state-of-the-art performance in conversational capabilities and visual grounding while remaining competitive in other radiology tasks. Ablation studies further highlight the benefit of joint training across multiple tasks, particularly for scenarios with limited annotated data. Together, these findings highlight the potential of RadVLM as a clinically relevant AI assistant, providing structured CXR interpretation and conversational capabilities to support more effective and accessible diagnostic workflows.

  • 15 authors
·
Feb 5, 2025

3D Reconstruction of Coronary Vessel Trees from Biplanar X-Ray Images Using a Geometric Approach

X-ray angiography is widely used in cardiac interventions to visualize coronary vessels, assess integrity, detect stenoses and guide treatment. We propose a framework for reconstructing 3D vessel trees from biplanar X-ray images which are extracted from two X-ray videos captured at different C-arm angles. The proposed framework consists of three main components: image segmentation, motion phase matching, and 3D reconstruction. An automatic video segmentation method for X-ray angiography to enable semantic segmentation for image segmentation and motion phase matching. The goal of the motion phase matching is to identify a pair of X-ray images that correspond to a similar respiratory and cardiac motion phase to reduce errors in 3D reconstruction. This is achieved by tracking a stationary object such as a catheter or lead within the X-ray video. The semantic segmentation approach assigns different labels to different object classes enabling accurate differentiation between blood vessels, balloons, and catheters. Once a suitable image pair is selected, key anatomical landmarks (vessel branching points and endpoints) are matched between the two views using a heuristic method that minimizes reconstruction errors. This is followed by a novel geometric reconstruction algorithm to generate the 3D vessel tree. The algorithm computes the 3D vessel centrelines by determining the intersection of two 3D surfaces. Compared to traditional methods based on epipolar constraints, the proposed approach simplifies there construction workflow and improves overall accuracy. We trained and validated our segmentation method on 62 X-ray angiography video sequences. On the test set, our method achieved a segmentation accuracy of 0.703. The 3D reconstruction framework was validated by measuring the reconstruction error of key anatomical landmarks, achieving a reprojection errors of 0.62mm +/- 0.38mm.

  • 4 authors
·
Sep 15, 2025

VectraYX-Vision-1B: A Sub-2B Spanish/LATAM Cybersecurity Vision-Language Model with Structured Visual Reasoning and Native Tool Use

We present VectraYX-Vision-1B, a sub-2B vision-language model (VLM) for Spanish/LATAM cybersecurity imagery, coupling a frozen SigLIP-so400m encoder to a 1.04B Spanish/LATAM security decoder via an MLP. To our knowledge, it is the first sub-2B VLM specialized for cyber UI (IDA, Ghidra, Wireshark, Nmap, Metasploit, Volatility) that answers in Spanish, emits structured reasoning via native <|think|> tokens, invokes tools via Model Context Protocol (<|tool_call|>), and exports to llama.cpp's LLaVA mmproj format for air-gapped deployment. We report a negative preliminary visual-grounding result: despite fully functional pipelines, the current vision SFT (400-1900 steps, ~16M tokens) yields near-zero B6 scores (0.08 tool-identification), ignoring image content. We specify remediation (longer SFT, >=60% replay, lower LR) and expose a checkpoint-loader bug (unstripped llm. prefix) masquerading as training collapse. Crucially, we introduce a 3-variant ablation matrix (V0: NoPE-every-4, V1: all-RoPE, V2: NoPE+learned 2D) to study if periodic no-positional-encoding (NoPE) layers help or hurt attention over the 729-token visual block. Code, configs, and weights are released to establish priority on this architectural question. We provide B1-B5 for the text backbone, text controls, preliminary B6/B7 scores, wall times, GGUF efficiency on CPU, and a corpus of 14,596 QA pairs across 10 domains. We open-source all models and trajectories: jsantillana/vectrayx-1b, jsantillana/vectrayx-vision-1b, and jsantillana/vectrayx-vision-1b-checks.

  • 1 authors
·
Aug 8 2

X-Ray-CoT: Interpretable Chest X-ray Diagnosis with Vision-Language Models via Chain-of-Thought Reasoning

Chest X-ray imaging is crucial for diagnosing pulmonary and cardiac diseases, yet its interpretation demands extensive clinical experience and suffers from inter-observer variability. While deep learning models offer high diagnostic accuracy, their black-box nature hinders clinical adoption in high-stakes medical settings. To address this, we propose X-Ray-CoT (Chest X-Ray Chain-of-Thought), a novel framework leveraging Vision-Language Large Models (LVLMs) for intelligent chest X-ray diagnosis and interpretable report generation. X-Ray-CoT simulates human radiologists' "chain-of-thought" by first extracting multi-modal features and visual concepts, then employing an LLM-based component with a structured Chain-of-Thought prompting strategy to reason and produce detailed natural language diagnostic reports. Evaluated on the CORDA dataset, X-Ray-CoT achieves competitive quantitative performance, with a Balanced Accuracy of 80.52% and F1 score of 78.65% for disease diagnosis, slightly surpassing existing black-box models. Crucially, it uniquely generates high-quality, explainable reports, as validated by preliminary human evaluations. Our ablation studies confirm the integral role of each proposed component, highlighting the necessity of multi-modal fusion and CoT reasoning for robust and transparent medical AI. This work represents a significant step towards trustworthy and clinically actionable AI systems in medical imaging.

  • 3 authors
·
Aug 17, 2025

XFlow: A Workflow Model for Instruction-Guided Lesion Segmentation in Chest X-rays

Existing text-guided segmentation models in the medical domain cover only a narrow set of anatomical structures and lesions in chest X-rays (CXRs), and most of them assume that the queried target is always present in the image. Instruction-guided lesion segmentation (ILS) was introduced to overcome these limitations by segmenting diverse lesion types from simple user instructions while also recognizing when the queried lesion is absent, and ROSALIA was proposed as the first model for this task. However, the masks produced by ROSALIA remain of limited quality, often carrying scattered noise. Moreover, ROSALIA predicts the mask in a single shot, which differs fundamentally from how radiologists perceive and delineate lesions in practice. A radiologist first surveys the entire thorax, then localizes the approximate region of abnormality, and only then refines the lesion contour. Motivated by this coarse-to-fine, multi-level perception process, we present XFlow, a workflow model for ILS that combines box-based localization with multi-turn point refinement. XFlow detects the lungs, decides whether the queried finding is present in each of them, and prompts a fine-tuned SAM with the lesion box for an initial mask. It then corrects that mask through point prompts until its boundary follows the lesion, leaving every intermediate decision visible. Our experiments show that XFlow achieves the best segmentation quality on both internal and external evaluation. Notably, it surpasses ROSALIA in segmentation quality even when the two are trained on the same lesion annotations. Code and model weights will be made publicly available.

kaist-ai KAIST AI
·
Sep 27

GRCD: Grounded Region Change Detection for Multi-Finding Chest X-Ray Pairs

Radiologists routinely compare current and prior chest X-rays to track disease progression, producing follow-up reports that describe multiple findings, each localised to an anatomical region and annotated with a temporal change status. Existing automated methods either generate reports from a single image without modelling temporal context, or incorporate temporal information but do not ground their outputs spatially. The few approaches that combine temporal reasoning with spatial grounding are restricted to single-finding descriptions, leaving multi-finding reports with mixed change directions unaddressed. We present GRCD, a framework for grounded report generation from chest X-ray pairs in the multi-finding setting. We first construct a rigorously cleaned dataset of temporal chest X-ray pairs by identifying and correcting two systematic labelling errors in the source annotations. We then introduce a Region-Guided Change Token module that encodes per-region temporal change across anatomical structures and injects this signal into a language model through a dual-pathway strategy combining prepended spatial tokens with gated cross-attention. On a multi-finding test set, GRCD outperforms existing baselines on text generation and clinical accuracy metrics, with gains in change detection. Ablation studies confirm that the dual-pathway design outperforms either integration strategy in isolation on text and clinical metrics, and that region-level change encoding is necessary for multi-finding generation. Code is available at https://github.com/UTSA-VIRLab/GRCD

  • 3 authors
·
Jul 1

Every Ablation Is a Dose: Counterweights and the Semblance of Self-Repair

Ablate a component of a language model, and other components often appear to adjust and compensate. This phenomenon, termed self-repair, has been observed repeatedly, but its mechanism remains unclear. The most systematic study to date concluded that self-repair is noisy and unlikely to have a single explanation. We argue that it has one: a gain already present before any ablation. Any intervention on a causally important component can be viewed as a point on a coordinate axis λ, the signed strength of a counterfactual contrast. Hence, conventional ablation methods are uncalibrated points on this axis. We show that the causal repair response for a fine-grained unit r is governed by an affine law, E_r(λ)=own_r+γ_rλ. The slope γ_r is a fixed coefficient that consistently influences the model, with or without ablation, and its sign determines whether the unit counteracts or reinforces the removed signal. On a factual-verdict task across four models from distinct families (Gemma, Qwen, LLaMA, and Mistral), we identify components including MLP neurons, OV neurons, and singular directions that follow this affine law, 68 of 81 downstream directions in all. Moreover, we can anticipate the magnitude of γ_r from the fixed weights. On the IOI circuit of GPT-2 Small, seven of the ten heads the intervention can reach follow the law, and all seven are counterweights. From this perspective, what may appear as self-repair is a counterweight performing its usual operation when the contrastive signal emerges at the core.

  • 3 authors
·
Sep 30

FluoroSAM: A Language-promptable Foundation Model for Flexible X-ray Image Segmentation

Language promptable X-ray image segmentation would enable greater flexibility for human-in-the-loop workflows in diagnostic and interventional precision medicine. Prior efforts have contributed task-specific models capable of solving problems within a narrow scope, but expanding to broader use requires additional data, annotations, and training time. Recently, language-aligned foundation models (LFMs) -- machine learning models trained on large amounts of highly variable image and text data thus enabling broad applicability -- have emerged as promising tools for automated image analysis. Existing foundation models for medical image analysis focus on scenarios and modalities where large, richly annotated datasets are available. However, the X-ray imaging modality features highly variable image appearance and applications, from diagnostic chest X-rays to interventional fluoroscopy, with varying availability of data. To pave the way toward an LFM for comprehensive and language-aligned analysis of arbitrary medical X-ray images, we introduce FluoroSAM, a language-promptable variant of the Segment Anything Model, trained from scratch on 3M synthetic X-ray images from a wide variety of human anatomies, imaging geometries, and viewing angles. These include pseudo-ground truth masks for 128 organ types and 464 tools with associated text descriptions. FluoroSAM is capable of segmenting myriad anatomical structures and tools based on natural language prompts, thanks to the novel incorporation of vector quantization (VQ) of text embeddings in the training process. We demonstrate FluoroSAM's performance quantitatively on real X-ray images and showcase on several applications how FluoroSAM is a key enabler for rich human-machine interaction in the X-ray image acquisition and analysis context. Code is available at https://github.com/arcadelab/fluorosam.

  • 8 authors
·
Mar 12, 2024

Surprised by Attention: Predictable Query Dynamics for Time Series Anomaly Detection

Multivariate time series anomalies often manifest as shifts in cross-channel dependencies rather than simple amplitude excursions. In autonomous driving, for instance, a steering command might be internally consistent but decouple from the resulting lateral acceleration. Residual-based detectors can miss such anomalies when flexible sequence models still reconstruct signals plausibly despite altered coordination. We introduce AxonAD, an unsupervised detector that treats multi-head attention query evolution as a short horizon predictable process. A gradient-updated reconstruction pathway is coupled with a history-only predictor that forecasts future query vectors from past context. This is trained via a masked predictor-target objective against an exponential moving average (EMA) target encoder. At inference, reconstruction error is combined with a tail-aggregated query mismatch score, which measures cosine deviation between predicted and target queries on recent timesteps. This dual approach provides sensitivity to structural dependency shifts while retaining amplitude-level detection. On proprietary in-vehicle telemetry with interval annotations and on the TSB-AD multi-variate suite (17 datasets, 180 series) with threshold-free and range-aware metrics, AxonAD improves ranking quality and temporal localization over strong baselines. Ablations confirm that query prediction and combined scoring are the primary drivers of the observed gains. Code is available at the URL https://github.com/iis-esslingen/AxonAD.

Simple Projection Variants Improve ColBERT Performance

Multi-vector dense retrieval methods like ColBERT systematically use a single-layer linear projection to reduce the dimensionality of individual vectors. In this study, we explore the implications of the MaxSim operator on the gradient flows of the training of multi-vector models and show that such a simple linear projection has inherent, if non-critical, limitations in this setting. We then discuss the theoretical improvements that could result from replacing this single-layer projection with well-studied alternative feedforward linear networks (FFN), such as deeper, non-linear FFN blocks, GLU blocks, and skip-connections, could alleviate these limitations. Through the design and systematic evaluation of alternate projection blocks, we show that better-designed final projections positively impact the downstream performance of ColBERT models. We highlight that many projection variants outperform the original linear projections, with the best-performing variants increasing average performance on a range of retrieval benchmarks across domains by over 2 NDCG@10 points. We then conduct further exploration on the individual parameters of these projections block in order to understand what drives this empirical performance, highlighting the particular importance of upscaled intermediate projections and residual connections. As part of these ablation studies, we show that numerous suboptimal projection variants still outperform the traditional single-layer projection across multiple benchmarks, confirming our hypothesis. Finally, we observe that this effect is consistent across random seeds, further confirming that replacing the linear layer of ColBERT models is a robust, drop-in upgrade.

  • 5 authors
·
Oct 14, 2025

RepConTUR: A Report-Conditioned Volumetric Multimodal Model for Abdominal Tumor Segmentation

Tumor delineation is required for radiotherapy planning, yet automatic segmentation is limited by errors, predominantly false positives, that distort dose and increase editing time. The radiology report accompanies the scan and localizes disease at the suborgan level, but existing text-promptable models condition on short referring phrases, and most operate in 2D. We present RepConTUR, a single native-3D early-fusion multimodal model that conditions volumetric abdominal tumor segmentation on the narrative report. We extend AbdomenAtlas 3.0 to a suborgan-level promptable segmentation dataset and generate report-based VQA pairs, yielding four report-derived tasks on the same annotations: referring segmentation (RES), report-grounded segmentation (GSEG), report generation (RRG), and visual question answering (VQA). We train RepConTUR, comprising a 3D CT encoder, an early-fusion language model, and a native-3D segmentation module, jointly on the four tasks. Across liver, kidney and pancreas, RepConTUR attains the highest Dice similarity coefficient (DSC), instance-wise precision, and detection F1 among the text-promptable baselines, and adding the report raises mean precision while leaving recall comparable. Against two vision-only specialists, nnU-Net and the report-supervised R-Super, RepConTUR attains the highest value on every in-domain metric for liver and pancreas and the highest mean DSC, recall, precision, and detection F1 over the four out-of-distribution public cohorts. Ablations indicate that conditioning on the narrative report raises detection F1 from 0.499 to 0.528 within the same model, that joint GSEG training raises RES F1 from 0.450 to 0.482, and that the native-3D segmentation module raises GSEG F1 from 0.139 to 0.528 over its 2D counterpart. Code is available at https://github.com/Oncosoft-Research/RepConTUR.

  • 7 authors
·
Oct 29

HyperTopo-Adapters: Geometry- and Topology-Aware Segmentation of Leaf Lesions on Frozen Encoders

Leaf-lesion segmentation is topology-sensitive: small merges, splits, or false holes can be biologically meaningful descriptors of biochemical pathways, yet they are weakly penalized by standard pixel-wise losses in Euclidean latents. I explore HyperTopo-Adapters, a lightweight, parameter-efficient head trained on top of a frozen vision encoder, which embeds features on a product manifold -- hyperbolic + Euclidean + spherical (H + E + S) -- to encourage hierarchical separation (H), local linear detail (E), and global closure (S). A topology prior complements Dice/BCE in two forms: (i) persistent-homology (PH) distance for evaluation and selection, and (ii) a differentiable surrogate that combines a soft Euler-characteristic match with total variation regularization for stable training. I introduce warm-ups for both the hyperbolic contrastive term and the topology prior, per-sample evaluation of structure-aware metrics (Boundary-F1, Betti errors, PD distance), and a min-PD within top-K Dice rule for checkpoint selection. On a Kaggle leaf-lesion dataset (N=2,940), early results show consistent gains in boundary and topology metrics (reducing Delta beta_1 hole error by 9%) while Dice/IoU remain competitive. The study is diagnostic by design: I report controlled ablations (curvature learning, latent dimensions, contrastive temperature, surrogate settings), and ongoing tests varying encoder strength (ResNet-50, DeepLabV3, DINOv2/v3), input resolution, PH weight, and partial unfreezing of late blocks. The contribution is an open, reproducible train/eval suite (available at https://github.com/ChimdiWalter/HyperTopo-Adapters) that isolates geometric/topological priors and surfaces failure modes to guide stronger, topology-preserving architectures.

  • 2 authors
·
Dec 28, 2025

LookAgain: Closed-Loop GUI Grounding with Visually Grounded Reflection

Recent graphical user interface (GUI) grounders have significantly advanced single-shot accuracy on standard benchmarks, yet their performance degrades sharply on small targets, densely packed controls and out-of-distribution interfaces. We attribute this gap to a paradigmatic limitation shared by existing approaches: none of them treats a produced coordinate as a hypothesis to be reflected upon and revised under new visual evidence. This manifests as three coupled issues: 1) Lack of post-hoc reflection. The prediction is frozen at the moment of emission, leaving no internal mechanism to challenge or refine it. 2) Visual evidence decoupled from the prediction. The auxiliary visual evidence is gathered to support the upcoming coordinate rather than to scrutinise the one already committed to. 3) Refinement over views, not over predictions. The iterative zoom-in refines the inspected region instead of inheriting a previous coordinate as a spatial prior to be corrected. In this paper, we propose LookAgain, a closed-loop GUI grounder driven by post-prediction visual reflection. LookAgain reformulates grounding as a multi-turn predict-look-again-refine process with two primitives: "locate" posts a coordinate hypothesis, renders a marker on the image and appends a local patch of the predicted region. It anchors the next reasoning step to the previous prediction as a spatial prior; "confirm" accepts or reject the hypothesis and terminates the procedure. We train the LookAgain grounder with SFT on constructed reflective trajectories as a cold start, followed by GRPO with terminal grounding correctness as the sole reward. Extensive experiments show that LookAgain consistently improves performance on both refusal-aware and general GUI grounding benchmarks, achieving state-of-the-art results. Comprehensive ablations further verify the effectiveness of the proposed framework.

  • 6 authors
·
Aug 9

Autonomous Multi-Modal LLM Agents for Treatment Planning in Focused Ultrasound Ablation Surgery

Focused Ultrasound Ablation Surgery (FUAS) has emerged as a promising non-invasive therapeutic modality, valued for its safety and precision. Nevertheless, its clinical implementation entails intricate tasks such as multimodal image interpretation, personalized dose planning, and real-time intraoperative decision-making processes that demand intelligent assistance to improve efficiency and reliability. We introduce FUAS-Agents, an autonomous agent system that leverages the multimodal understanding and tool-using capabilities of large language models (LLMs). By integrating patient profiles and MRI data, FUAS-Agents orchestrates a suite of specialized medical AI tools, including segmentation, treatment dose prediction, and clinical guideline retrieval, to generate personalized treatment plans comprising MRI image, dose parameters, and therapeutic strategies. We evaluate the system in a uterine fibroid treatment scenario. Human assessment by four senior FUAS experts indicates that 82.5%, 82.5%, 87.5%, and 97.5% of the generated plans were rated 4 or above (on a 5-point scale) in terms of completeness, accuracy, fluency, and clinical compliance, respectively. These results demonstrate the potential of LLM-driven agents in enhancing decision-making across complex clinical workflows, and exemplify a translational paradigm that combines general-purpose models with specialized expert systems to solve practical challenges in vertical healthcare domains.

  • 9 authors
·
May 27, 2025

Learning to Generate Object Interactions with Physics-Guided Video Diffusion

Recent models for video generation have achieved remarkable progress and are now deployed in film, social media production, and advertising. Beyond their creative potential, such models also hold promise as world simulators for robotics and embodied decision making. Despite strong advances, however, current approaches still struggle to generate physically plausible object interactions and lack physics-grounded control mechanisms. To address this limitation, we introduce KineMask, an approach for physics-guided video generation that enables realistic rigid body control, interactions, and effects. Given a single image and a specified object velocity, our method generates videos with inferred motions and future object interactions. We propose a two-stage training strategy that gradually removes future motion supervision via object masks. Using this strategy we train video diffusion models (VDMs) on synthetic scenes of simple interactions and demonstrate significant improvements of object interactions in real scenes. Furthermore, KineMask integrates low-level motion control with high-level textual conditioning via predictive scene descriptions, leading to effective support for synthesis of complex dynamical phenomena. Extensive experiments show that KineMask achieves strong improvements over recent models of comparable size. Ablation studies further highlight the complementary roles of low- and high-level conditioning in VDMs. Our code, model, and data will be made publicly available.

  • 5 authors
·
Oct 2, 2025

Electron Acceleration and Jet-Facilitated Escape in an M Class Solar Flare on 2002 August 19

Sudden jets of collimated plasma arise from many locations on the Sun, including active regions. The magnetic field along which a jet emerges is often open to interplanetary space, offering a clear "escape route" for any flare-accelerated electrons and making jets lucrative targets for studying particle acceleration and the solar sources of transient heliospheric events. Bremsstrahlung hard X-rays (HXRs) could, in principle, trace the accelerated electrons that escape along the paths of the jets, but measurements of the escaping electron beams are customarily difficult due to the low densities of the corona. In this work, we augment HXR observations with gyrosynchrotron emission observed in microwaves, as well as extreme ultraviolet (EUV) emission and modeling to investigate flare-accelerated electrons in a coronal jet. HXR and microwave data from RHESSI and OVSA, respectively, give complementary insight into electron spectra and locations, including the presence of accelerated electrons in the jet itself. High-time-resolution HXR data from the Konus-Wind instrument suggest electron acceleration timescales on the order of 1 second or shorter. We model the energetic electron distributions in the GX Simulator framework using SoHO/MDI, RHESSI, TRACE, and OVSA data as constraints. The result is a modeled distribution, informed and constrained by measurements, of accelerated electrons as they escape the Sun. Combining the detection of microwave gyrosynchrotron emission from an open, rather than closed, magnetic configuration, with realistic 3D modeling constrained by magnetograms, EUV, and X-ray emission, we obtain the most stringent constraints to date on the accelerated electrons within a solar jet.

  • 2 authors
·
Oct 29, 2018

When Online Adaptation Hurts: Parameter-Frozen Test-Time Ensembling for Continual Medical Image Segmentation

Medical image segmenters often get worse when sites, scanner vendors, or protocols change. Continual test-time adaptation (CTTA) addresses this problem without target labels, but it can be impossible to update a model on a non-stationary stream and can lead to a lot of errors. We examine a more reasonable and meaningful alternative: parameter-frozen inference enhancement(PIE). We use a source-trained segmenter that learns about anatomy-preserving scale and flip views, maps their predictions back to the native location, and averages the probabilities. We do not modify the weights of the model or the normalization statistics. On a cardiac MRI stream from M\&Ms, which is trained on vendor A and evaluated sequentially on vendors B, C, and D, PIE has 0.7786 mean Dice, compared to 0.7680 for source-only inference and 0.7388--0.7416 for five other online-adaptation baselines. The controlled ablations show that performance saturates at 28 views, and confidence weighting, class-prior correction, connected-component filtering, morphological refinement, and inter-slice smoothing have no effect or cause negative transfer. Qualitative results on cardiac MRI and fundus images are also consistent with the frozen ensemble keeping thinner and nested anatomical structures. These results provide a strong, stable baseline for medical CTTA and expose an important failure mode: adaptation and handcrafted refinement can be less reliable than carefully designed inference.

  • 1 authors
·
Sep 17

BS-LDM: Effective Bone Suppression in High-Resolution Chest X-Ray Images with Conditional Latent Diffusion Models

Lung diseases represent a significant global health challenge, with Chest X-Ray (CXR) being a key diagnostic tool due to their accessibility and affordability. Nonetheless, the detection of pulmonary lesions is often hindered by overlapping bone structures in CXR images, leading to potential misdiagnoses. To address this issue, we developed an end-to-end framework called BS-LDM, designed to effectively suppress bone in high-resolution CXR images. This framework is based on conditional latent diffusion models and incorporates a multi-level hybrid loss-constrained vector-quantized generative adversarial network which is crafted for perceptual compression, ensuring the preservation of details. To further enhance the framework's performance, we introduce offset noise and a temporal adaptive thresholding strategy. These additions help minimize discrepancies in generating low-frequency information, thereby improving the clarity of the generated soft tissue images. Additionally, we have compiled a high-quality bone suppression dataset named SZCH-X-Rays. This dataset includes 818 pairs of high-resolution CXR and dual-energy subtraction soft tissue images collected from a partner hospital. Moreover, we processed 241 data pairs from the JSRT dataset into negative images, which are more commonly used in clinical practice. Our comprehensive experimental and clinical evaluations reveal that BS-LDM excels in bone suppression, underscoring its significant clinical value.

  • 10 authors
·
Dec 20, 2024

Unsupervised Audio-Visual Lecture Segmentation

Over the last decade, online lecture videos have become increasingly popular and have experienced a meteoric rise during the pandemic. However, video-language research has primarily focused on instructional videos or movies, and tools to help students navigate the growing online lectures are lacking. Our first contribution is to facilitate research in the educational domain, by introducing AVLectures, a large-scale dataset consisting of 86 courses with over 2,350 lectures covering various STEM subjects. Each course contains video lectures, transcripts, OCR outputs for lecture frames, and optionally lecture notes, slides, assignments, and related educational content that can inspire a variety of tasks. Our second contribution is introducing video lecture segmentation that splits lectures into bite-sized topics that show promise in improving learner engagement. We formulate lecture segmentation as an unsupervised task that leverages visual, textual, and OCR cues from the lecture, while clip representations are fine-tuned on a pretext self-supervised task of matching the narration with the temporally aligned visual content. We use these representations to generate segments using a temporally consistent 1-nearest neighbor algorithm, TW-FINCH. We evaluate our method on 15 courses and compare it against various visual and textual baselines, outperforming all of them. Our comprehensive ablation studies also identify the key factors driving the success of our approach.

  • 4 authors
·
Oct 29, 2022

Deep End-to-end Adaptive k-Space Sampling, Reconstruction, and Registration for Dynamic MRI

Dynamic MRI enables a range of clinical applications, including cardiac function assessment, organ motion tracking, and radiotherapy guidance. However, fully sampling the dynamic k-space data is often infeasible due to time constraints and physiological motion such as respiratory and cardiac motion. This necessitates undersampling, which degrades the quality of reconstructed images. Poor image quality not only hinders visualization but also impairs the estimation of deformation fields, crucial for registering dynamic (moving) images to a static reference image. This registration enables tasks such as motion correction, treatment planning, and quantitative analysis in applications like cardiac imaging and MR-guided radiotherapy. To overcome the challenges posed by undersampling and motion, we introduce an end-to-end deep learning (DL) framework that integrates adaptive dynamic k-space sampling, reconstruction, and registration. Our approach begins with a DL-based adaptive sampling strategy, optimizing dynamic k-space acquisition to capture the most relevant data for each specific case. This is followed by a DL-based reconstruction module that produces images optimized for accurate deformation field estimation from the undersampled moving data. Finally, a registration module estimates the deformation fields aligning the reconstructed dynamic images with a static reference. The proposed framework is independent of specific reconstruction and registration modules allowing for plug-and-play integration of these components. The entire framework is jointly trained using a combination of supervised and unsupervised loss functions, enabling end-to-end optimization for improved performance across all components. Through controlled experiments and ablation studies, we validate each component, demonstrating that each choice contributes to robust motion estimation from undersampled dynamic data.

  • 3 authors
·
Mar 20, 2025

Source Anchoring for Physical Consistency in Flow Matching Models

Deep generative models are used to solve partial differential equations and model distributions of physical system states, but ensuring that the generated samples satisfy the governing laws remains challenging. Projection-based flow-matching methods enforce physics by correcting the flow from an unconstrained noise distribution. These corrections shift the generated samples away from the distribution of target solutions, especially in high noise regions. To address this limitation, we propose Source Anchoring for Physical Consistency (SAPC), a Functional Flow Matching method that encodes the physical constraints into the source noise before generation begins. We evaluate SAPC on five systems governed by partial differential equations, covering six tasks with linear and non-linear dynamics, and compare results against five baselines and the unconstrained backbone. Anchoring the source reduces the need for large corrections that drive samples onto admissible but off-distribution states, and SAPC reproduces the target distributions most accurately on every evaluated task, while matching the constraint precision of the best projection-based baselines. Ablation experiments show that this gain arises from pairing source projection with a matched training objective that regresses toward the projected source. These results identify the source distribution as a key design choice for physically consistent generative modelling.

  • 3 authors
·
Sep 26

Apodex Discovery: Reality Benchmarks and Environments for Evaluating and Building Discoverative Artificial Intelligence

Apollo did not reach the Moon merely because its engineers could solve difficult equations. It succeeded by turning a distant ambition into a mission architecture of explicit objectives, simulation, verification, and repeated correction. AI now faces a similar transition: frontier models can solve difficult tasks once the problem, tools, and success criteria are specified, yet consequential real-world challenges rarely arrive in an executable or verifiable form. We introduce Apodex Discovery, a framework for building and evaluating discoverative AI through the heavy-duty solver, a system comprising a foundation model, harness, tools, and control policies that pursues extended, stateful, verifiable investigations. It has three core components. First, a problem-scouting process surveyed 561 industries across 16 sectors, assembled 423 high-value real-world problems, and selected 20 for the initial release. Second, a common environment-task-episode abstraction provides data, tools, constraints, feedback, trajectory recording, and verification of intermediate artifacts and final submissions. Third, HDS6 evaluates Tools, Repair, Alternatives, Coherence, Evidence, and Scope independently of final-task success. In AAV capsid design, Apodex surpassed the published state of the art by 7% across viability, tropism, structure prediction, and generative design. In drug repurposing and reformulation, a task-specific biomedical environment improved the mean normalized prediction score of GPT-5.5 and GPT-5.6-sol by 2.5 and 7.6 points over the same closed-book backbone. Controlled ablations show that the fixed TRACES episode interface enables attribution of performance differences to specific solver components. Apodex Discovery moves AI evaluation beyond predefined benchmarks toward verifiable investigations aimed at genuine discovery.

apodex Apodex
·
Aug 10 2

Amortized Opacity Marginalization Improves C/O Interval Calibration for Brown-Dwarf Retrievals

Molecular line lists disagree at a level that measurably shifts retrieved C/O, so retrievals conditioned on a single list omit a dominant systematic from their error bars. Classical marginalization re-runs a full retrieval under K opacity realizations per object. We move that cost into simulation: while generating the training set we randomize opacities (smooth multiplicative Fourier fields in logν plus a discrete line-list mixture, under a deliberately broad prior informed by measured inter-list differences), so a neural posterior estimator learns an already-marginalized posterior. Conceptually, this is the amortized analogue of repeating a conventional retrieval under many plausible opacity realizations and averaging the resulting posteriors. On perturbed held-out spectra (n=2048) a standard NPE covers nominal 90% C/O intervals 43.3% of the time against 82.4% for a compute-matched marginalized network; three-seed control ensembles reach 93.2% on clean data but 61.4% under perturbation, against 89.4% marginalized, isolating the deficit as opacity-induced (TARP joint expected-coverage deviation 0.005 against 0.035). An axis ablation traces the gain to the continuous field (45.4% for the discrete swaps alone, 79.3% for the field alone). Applying the 105 real bad-pixel masks with median filling then collapsed the ensemble's C/O coverage from 0.901 to 0.479; retraining on the same mask distribution and pooling three such seeds returns a nominal 0.905 C/O and 0.891 overall under the full deployment path, still in simulation (n=1024, same 105 masks), at 0.21 to 0.31 of the prior width. On 105 JWST/G395H spectral products of 13 late-T/Y dwarfs, single marginalized networks bracket the Hood et al. (2024) T8 benchmark C/O where the control excludes it, a consistency check rather than a validation, at 1.6-2.6x wider intervals.

  • 1 authors
·
Aug 31

Text-to-Vector Generation with Neural Path Representation

Vector graphics are widely used in digital art and highly favored by designers due to their scalability and layer-wise properties. However, the process of creating and editing vector graphics requires creativity and design expertise, making it a time-consuming task. Recent advancements in text-to-vector (T2V) generation have aimed to make this process more accessible. However, existing T2V methods directly optimize control points of vector graphics paths, often resulting in intersecting or jagged paths due to the lack of geometry constraints. To overcome these limitations, we propose a novel neural path representation by designing a dual-branch Variational Autoencoder (VAE) that learns the path latent space from both sequence and image modalities. By optimizing the combination of neural paths, we can incorporate geometric constraints while preserving expressivity in generated SVGs. Furthermore, we introduce a two-stage path optimization method to improve the visual and topological quality of generated SVGs. In the first stage, a pre-trained text-to-image diffusion model guides the initial generation of complex vector graphics through the Variational Score Distillation (VSD) process. In the second stage, we refine the graphics using a layer-wise image vectorization strategy to achieve clearer elements and structure. We demonstrate the effectiveness of our method through extensive experiments and showcase various applications. The project page is https://intchous.github.io/T2V-NPR.

  • 3 authors
·
May 16, 2024

Measurement of the properties of Higgs boson production at s = 13 TeV in the Htoγγ channel using 139 fb^{-1} of pp collision data with the ATLAS experiment

Measurements of Higgs boson production cross-sections are carried out in the diphoton decay channel using 139 fb^{-1} of pp collision data at s = 13 TeV collected by the ATLAS experiment at the LHC. The analysis is based on the definition of 101 distinct signal regions using machine-learning techniques. The inclusive Higgs boson signal strength in the diphoton channel is measured to be 1.04^{+0.10}_{-0.09}. Cross-sections for gluon-gluon fusion, vector-boson fusion, associated production with a W or Z boson, and top associated production processes are reported. An upper limit of 10 times the Standard Model prediction is set for the associated production process of a Higgs boson with a single top quark, which has a unique sensitivity to the sign of the top quark Yukawa coupling. Higgs boson production is further characterized through measurements of Simplified Template Cross-Sections (STXS). In total, cross-sections of 28 STXS regions are measured. The measured STXS cross-sections are compatible with their Standard Model predictions, with a p-value of 93%. The measurements are also used to set constraints on Higgs boson coupling strengths, as well as on new interactions beyond the Standard Model in an effective field theory approach. No significant deviations from the Standard Model predictions are observed in these measurements, which provide significant sensitivity improvements compared to the previous ATLAS results.

  • 1 authors
·
Jul 1, 2022

A Review of Longitudinal Radiology Report Generation: Dataset Composition, Methods, and Performance Evaluation

Chest Xray imaging is a widely used diagnostic tool in modern medicine, and its high utilization creates substantial workloads for radiologists. To alleviate this burden, vision language models are increasingly applied to automate Chest Xray radiology report generation (CXRRRG), aiming for clinically accurate descriptions while reducing manual effort. Conventional approaches, however, typically rely on single images, failing to capture the longitudinal context necessary for producing clinically faithful comparison statements. Recently, growing attention has been directed toward incorporating longitudinal data into CXR RRG, enabling models to leverage historical studies in ways that mirror radiologists diagnostic workflows. Nevertheless, existing surveys primarily address single image CXRRRG and offer limited guidance for longitudinal settings, leaving researchers without a systematic framework for model design. To address this gap, this survey provides the first comprehensive review of longitudinal radiology report generation (LRRG). Specifically, we examine dataset construction strategies, report generation architectures alongside longitudinally tailored designs, and evaluation protocols encompassing both longitudinal specific measures and widely used benchmarks. We further summarize LRRG methods performance, alongside analyses of different ablation studies, which collectively highlight the critical role of longitudinal information and architectural design choices in improving model performance. Finally, we summarize five major limitations of current research and outline promising directions for future development, aiming to lay a foundation for advancing this emerging field.

  • 6 authors
·
Oct 14, 2025

End-to-End Autonomous Recursive Arborescence Deformable Flow and Non-Linear Hemodynamics for Patient-Specific Coronary Centerline Extraction

Extracting patient-specific vascular trees from volumetric medical images is fundamental to computational angiography and non-invasive hemodynamic assessment. Conventional voxel segmentation models often sever delicate bifurcations, while heuristic Euclidean Minimum Spanning Trees introduce non-anatomical shortcuts. Moreover, linear Poiseuille flow neglects quadratic kinetic dissipation across arterial narrowings, underestimating ischemia. We formulate an end-to-end framework decoupling continuous geometric arborescence generation from non-linear hemodynamics. First, an autonomous 3D Ostium Landmark Localization Head with dual-sinus query channels and spherical-gated refinement eliminates centerline seeding dependency, achieving cohort mean localization error of 7.63 mm (7.43 mm LCA, 7.83 mm RCA; 71.4% <= 8.0 mm) from raw contrast context. Second, a Spatially-Grounded Deformable Step Flow Architecture queries continuous 3D feature pyramids via trilinear sampling, sequentially generating trajectories with anchor boundary enforcement (X(0) = P_start). Third, a Top-Down Recursive Arborescence State Machine detects bifurcation peaks via Tree-NMS and parameterizes predecessor parent pointers (p_k < k), guaranteeing single connected acyclic tree topology (beta_0 = 1, beta_1 = 0) with differentiable step termination. Fourth, an iterative Picard non-linear Kirchhoff solver with Young-Tsai / Gould quadratic dissipation enforces machine-precision mass conservation (residual 5.82e-11 mL/s). Across 14 development patients under standardized in-silico stenosis stress testing (Q_0 = 4.0 mL/s), linear Poiseuille flow misclassifies 75% diameter lesions as non-ischemic (FFR > 0.80) in 14/14 cases, whereas our non-linear solver captures functional ischemia (FFR = 0.5864, lesion disparity 32.89 mmHg, p = 6.10e-5) with 3.66x collateral shunting. Test set firewall isolation was maintained.

  • 2 authors
·
Oct 4

Structured Proper Loss Geometries for Multiclass Classification: Theory and Controlled Empirical Evaluation

Strictly proper scoring rules identify the true conditional class distribution at population level, but their curvature can alter optimization and finite-sample behavior. We study three multiclass objectives: a class-aware quadratic Bregman score (CAPM), a strongly convex generator with constrained log-cosh ridges (HPG), and an HPG objective with an annealed probability-margin penalty (APMS). CAPM is treated as a structured instance of established quadratic scoring-rule theory. We derive conditional-regret, curvature, range, and logit-gradient bounds for CAPM and HPG, and prove exact penalty-range and conditional-target displacement bounds for APMS. Controlled five-seed experiments use Digits, Wisconsin breast cancer, and synthetic confusion and long-tail problems under clean labels, symmetric and pair-flip corruption, class imbalance, calibration evaluation, input corruption, and first-order adversarial perturbations. The candidates are close to cross-entropy on clean data and show descriptive gains in some noisy-label cells, but the five-seed comparisons are interpreted descriptively rather than as significance evidence. The selected noisy-label baselines perform better on Digits with 40% symmetric label noise, and explicit prior-adjustment methods perform better in the 30:1 synthetic long-tail experiment. Ablations do not show a consistent benefit from the candidate-specific graph, ridge, or margin components. The mathematical analysis establishes the stated properties, and the experiments delimit the empirical evidence; together they do not support a claim of general superiority.

  • 1 authors
·
Jun 27

DRIFT-Net: A Spectral--Coupled Neural Operator for PDEs Learning

Learning PDE dynamics with neural solvers can significantly improve wall-clock efficiency and accuracy compared with classical numerical solvers. In recent years, foundation models for PDEs have largely adopted multi-scale windowed self-attention, with the scOT backbone in Poseidon serving as a representative example. However, because of their locality, truly globally consistent spectral coupling can only be propagated gradually through deep stacking and window shifting. This weakens global coupling and leads to error accumulation and drift during closed-loop rollouts. To address this, we propose DRIFT-Net. It employs a dual-branch design comprising a spectral branch and an image branch. The spectral branch is responsible for capturing global, large-scale low-frequency information, whereas the image branch focuses on local details and nonstationary structures. Specifically, we first perform controlled, lightweight mixing within the low-frequency range. Then we fuse the spectral and image paths at each layer via bandwise weighting, which avoids the width inflation and training instability caused by naive concatenation. The fused result is transformed back into the spatial domain and added to the image branch, thereby preserving both global structure and high-frequency details across scales. Compared with strong attention-based baselines, DRIFT-Net achieves lower error and higher throughput with fewer parameters under identical training settings and budget. On Navier--Stokes benchmarks, the relative L_{1} error is reduced by 7\%--54\%, the parameter count decreases by about 15\%, and the throughput remains higher than scOT. Ablation studies and theoretical analyses further demonstrate the stability and effectiveness of this design. The code is available at https://github.com/cruiseresearchgroup/DRIFT-Net.

Ablation Studies in Artificial Neural Networks

Ablation studies have been widely used in the field of neuroscience to tackle complex biological systems such as the extensively studied Drosophila central nervous system, the vertebrate brain and more interestingly and most delicately, the human brain. In the past, these kinds of studies were utilized to uncover structure and organization in the brain, i.e. a mapping of features inherent to external stimuli onto different areas of the neocortex. considering the growth in size and complexity of state-of-the-art artificial neural networks (ANNs) and the corresponding growth in complexity of the tasks that are tackled by these networks, the question arises whether ablation studies may be used to investigate these networks for a similar organization of their inner representations. In this paper, we address this question and performed two ablation studies in two fundamentally different ANNs to investigate their inner representations of two well-known benchmark datasets from the computer vision domain. We found that features distinct to the local and global structure of the data are selectively represented in specific parts of the network. Furthermore, some of these representations are redundant, awarding the network a certain robustness to structural damages. We further determined the importance of specific parts of the network for the classification task solely based on the weight structure of single units. Finally, we examined the ability of damaged networks to recover from the consequences of ablations by means of recovery training. We argue that ablations studies are a feasible method to investigate knowledge representations in ANNs and are especially helpful to examine a networks robustness to structural damages, a feature of ANNs that will become increasingly important for future safety-critical applications.

  • 4 authors
·
Feb 17, 2019

Motion simulation of radio-labeled cells in whole-body positron emission tomography

Cell tracking is a subject of active research gathering great interest in medicine and biology. Positron emission tomography (PET) is well suited for tracking radio-labeled cells in vivo due to its exceptional sensitivity and whole-body capability. For validation, ground-truth data are desirable that realistically mimic the flow of cells in a clinical situation. This study develops a workflow (CeFloPS) for simulating moving radio-labeled cells in a human phantom. From the XCAT phantom, the blood vessels are reduced to nodal networks along which cells can move and distribute to organs and tissues. The movement is directed by the blood flow, which is calculated in each node using the Hagen-Pooiseuille equation and Kirchhoff's laws assuming laminar flow. Organs are voxelized and movement of cells from artery entry to vein exit is generated via a biased 3D random walk. The probabilities of cells moving or remaining in tissues are derived from rate constants of tracer kinetic-based compartment modeling. PET listmode data is generated using the Monte-Carlo simulation framework GATE based on the definition of a large-body PET scanner with cell paths as moving radioactive sources and the XCAT phantom providing attenuation data. From the flow simulation of 100,000 cells, 100 sample cells were further processed by GATE and listmode data was reconstructed into images for comparison. As demonstrated by comparisons of simulated and reconstructed cell distributions, CeFloPS is capable of simulating cell behavior in whole-body PET. It achieves this simulation in a way that is anatomically and physiologically reasonable, thereby providing valuable data for the development and validation of cell tracking algorithms.

  • 5 authors
·
Jul 10, 2024

Probing X-ray Timing and Spectral Variability in the Blazar PKS 2155-304 Over a Decade of XMM-Newton Observations

Blazars, a class of active galactic nuclei (AGN) powered by supermassive black holes, are known for their remarkable variability across multiple timescales and wavelengths. With advancements in both ground- and space-based telescopes, our understanding of AGN central engines has significantly improved. However, the mechanisms driving this variability remain elusive, and continue to fascinate both theorists and observers alike. The primary objective of this study is to constrain the X-ray variability properties of the TeV blazar PKS 2155-304. We conduct a comprehensive X-ray spectral and timing analysis, focusing on both long-term and intra-day variability. This analysis uses data from 22 epochs of XMM-Newton EPIC-pn observations, collected over 15 years (2000-2014). To investigate the variability of the source, we applied both timing and spectral analyses. For the timing analysis, we estimated fractional variability, variability amplitude, minimum variability timescales, flux distribution, and power spectral density (PSD). In the spectral analysis, we fitted the X-ray spectra using power-law, log-parabola, and broken power-law (BPL) models to determine the best-fitting parameters. Additionally, we studied the hardness ratio (HR). We observed moderate intra-day variability in most of the light curves. Seven out of the twenty-two observations showed a clear bimodal flux distribution, indicating the presence of two distinct flux states. Our analysis revealed a variable power-law PSD slope. Most HR plots did not show significant variation with flux, except for one observation (OBSID 0124930501), where HR increased with flux (Count/s). The fitted X-ray spectra favored the BPL model for the majority of observations. The findings of this work shed light on the intraday variability of blazars, providing insights into the non-thermal jet processes that drive the observed flux variations.

  • 8 authors
·
Oct 2, 2024

XGLASS: X-Ray, Gaze and Language Assisted Slice Sequencing for CT Volumes

Vision-language models (VLMs) achieve remarkable performance on 2D medical images, such as X-rays or pathology images, while 3D VLMs that directly process CT/MRI volumes lag behind due to limited 3D training data and the predominance of 2D foundation architectures. To leverage powerful 2D VLMs for analyzing medical volumes, which contain hundreds of slices, it is therefore necessary to focus only on those few slices, which are diagnostically relevant. To enable such a prioritization, we propose XGLASS, a method that transfers medical expertise from 2D X-rays to 3D CT for task-aware slice prioritization. XGLASS uses disease-conditioned importance maps derived from language-aligned radiologist gaze on X-rays and spatially aligns them with coronal CT projections, bringing gaze priors and CT content into a shared 2D representation. The fused gaze-prior/CT projection is then used to predict a disease-specific ordering of axial slices, prioritizing diagnostically relevant slices. XGLASS significantly improves budgeted retrieval over 2D and 3D-native baselines, achieving a top-10 hit rate up to 75.9% for the best-performing disease. In practice, this means that after inspecting only the top 10 slices (4.17% of a 240-slice scan), XGLASS identifies a diagnostically relevant slice in more than 75% of cases. For downstream slice-wise finding classification, an XGLASS-selected 30-slice candidate set reduces model calls by 87.5% while improving F1 by 11.3 percentage points over all-slice inference, 4.2 points over the strongest 2D selector, and remains competitive with 3D-native selectors while requiring up to 130.8 times less time and 10.9 times less GPU memory per finding, supporting its use as a lightweight preselector for volumetric CT analysis. The code and pretrained checkpoint are available on https://github.com/michaelgloeckler/XGLASS.

  • 2 authors
·
Oct 18

ZS-VCOS: Zero-Shot Video Camouflaged Object Segmentation By Optical Flow and Open Vocabulary Object Detection

Camouflaged object segmentation presents unique challenges compared to traditional segmentation tasks, primarily due to the high similarity in patterns and colors between camouflaged objects and their backgrounds. Effective solutions to this problem have significant implications in critical areas such as pest control, defect detection, and lesion segmentation in medical imaging. Prior research has predominantly emphasized supervised or unsupervised pre-training methods, leaving zero-shot approaches significantly underdeveloped. Existing zero-shot techniques commonly utilize the Segment Anything Model (SAM) in automatic mode or rely on vision-language models to generate cues for segmentation; however, their performances remain unsatisfactory, due to the similarity of the camouflaged object and the background. This work studies how to avoid training by integrating large pre-trained models like SAM-2 and Owl-v2 with temporal information into a modular pipeline. Evaluated on the MoCA-Mask dataset, our approach achieves outstanding performance improvements, significantly outperforming existing zero-shot methods by raising the F-measure (F_beta^w) from 0.296 to 0.628. Our approach also surpasses supervised methods, increasing the F-measure from 0.476 to 0.628. Additionally, evaluation on the MoCA-Filter dataset demonstrates an increase in the success rate from 0.628 to 0.697 when compared with FlowSAM, a supervised transfer method. A thorough ablation study further validates the individual contributions of each component. Besides our main contributions, we also highlight inconsistencies in previous work regarding metrics and settings. Code can be found in https://github.com/weathon/vcos.

  • 3 authors
·
Apr 10, 2025

Vascular anatomy-aware self-supervised pre-training for X-ray angiogram analysis

X-ray angiography is the gold standard imaging modality for cardiovascular diseases. However, current deep learning approaches for X-ray angiogram analysis are severely constrained by the scarcity of annotated data. While large-scale self-supervised learning (SSL) has emerged as a promising solution, its potential in this domain remains largely unexplored, primarily due to the lack of effective SSL frameworks and large-scale datasets. To bridge this gap, we introduce a vascular anatomy-aware masked image modeling (VasoMIM) framework that explicitly integrates domain-specific anatomical knowledge. Specifically, VasoMIM comprises two key designs: an anatomy-guided masking strategy and an anatomical consistency loss. The former strategically masks vessel-containing patches to compel the model to learn robust vascular semantics, while the latter preserves structural consistency of vessels between original and reconstructed images, enhancing the discriminability of the learned representations. In conjunction with VasoMIM, we curate XA-170K, the largest X-ray angiogram pre-training dataset to date. We validate VasoMIM on four downstream tasks across six datasets, where it demonstrates superior transferability and achieves state-of-the-art performance compared to existing methods. These findings highlight the significant potential of VasoMIM as a foundation model for advancing a wide range of X-ray angiogram analysis tasks. VasoMIM and XA-170K will be available at https://github.com/Dxhuang-CASIA/XA-SSL.

  • 11 authors
·
Feb 11

Dual-Rate Force-Image Control with Model-Based Orientation Limits for Robotic Ultrasound

Robotic ultrasound couples a high-rate contact-force loop with slower, delayed image feedback, so image-guided ultrasound probe rotation can perturb contact force before the resulting image response is observed. We derive a closed-form orientation-rate limit that bounds the modeled rotation-induced estimated-force excursion over a finite horizon while accounting for disturbance rejection by the fast force loop. The limit depends on local contact stiffness, force-loop gains, a conservative rotation-to-force gain bound, the excursion budget, and the prediction horizon. We implement this model in a dual-rate controller with timestamp-based delay reconstruction and joint-torque-based force estimation, and evaluate it on a curved gelatin phantom using paired controller comparisons and component ablations. Relative to unconstrained image guidance, the proposed rate-limited controller reduced first-second root-mean-square (RMS) estimated-force error by 0.40 N while increasing cue-convergence time by 0.94 s. A fixed rate cap near the analytically predicted ceiling produced no resolvable difference in force error and converged 0.32 s faster, indicating that the principal practical value of the model is the rate-design rule rather than online prediction. Delay reconstruction had no resolvable effect at the tested latency. A single-subject popliteal scan demonstrated feasibility, although the image cue was noise-limited on heterogeneous tissue.

  • 4 authors
·
Oct 5

How Fragile Is Safety Alignment at Frontier Scale? A Single-Direction Attack on a 320B MoE

Directional ablation removes an aligned language model's ability to refuse by projecting a single "refusal direction" out of the weights that write the residual stream. It needs no gradient-based training and no optimization, only a few hundred contrastive prompts, which makes it the canonical white-box attack on open-weight alignment. However, it has been established only on dense models up to roughly 70B parameters. We study whether it survives the shift to frontier mixture-of-experts (MoE) models whose residual streams are no longer a single tensor and whose weights ship quantized. We apply it to GLM-5.3-Flash (320B parameters, 288 routed experts, a four-wide hyper-connection residual, block-FP8). The attack survives the architecture, but what it reaches is no longer where a reader of the original recipe would look for it. Editing the attention, dense and routed-expert writers on their own removes 0.039, 0.016 and 0.148 of refusal respectively; editing all three together removes 0.776. As a result, 74% of the effect exists only under the joint intervention. The part the conventional recipe reaches by module-name matching accounts for 0.066 of that 0.776, which is why it fails silently on an MoE. The effect does not follow from removing just any direction: ablating a random direction orthogonal to it leaves refusal unchanged. A category-concentrated residue survives every edit we tried: subspaces fitted on violence, sexual content and hate leave measurable refusal at every rank from 1 to 12. We report the method, the 41-89 percentage-point reductions it achieves across seven harmful benchmarks with no detected change in capability, and the boundary where it stops.

  • 3 authors
·
Sep 8

4D Vessel Reconstruction for Benchtop Thrombectomy Analysis

Introduction: Mechanical thrombectomy can cause vessel deformation and procedure-related injury. Benchtop models are widely used for device testing, but time-resolved, full-field 3D vessel-motion measurements remain limited. Methods: We developed a nine-camera, low-cost multi-view workflow for benchtop thrombectomy in silicone middle cerebral artery phantoms (2160p, 20 fps). Multi-view videos were calibrated, segmented, and reconstructed with 4D Gaussian Splatting. Reconstructed point clouds were converted to fixed-connectivity edge graphs for region-of-interest (ROI) displacement tracking and a relative surface-based stress proxy. Stress-proxy values were derived from edge stretch using a Neo-Hookean mapping and reported as comparative surface metrics. A synthetic Blender pipeline with known deformation provided geometric and temporal validation. Results: In synthetic bulk translation, the stress proxy remained near zero for most edges (median approx 0 MPa; 90th percentile 0.028 MPa), with sparse outliers. In synthetic pulling (1-5 mm), reconstruction showed close geometric and temporal agreement with ground truth, with symmetric Chamfer distance of 1.714-1.815 mm and precision of 0.964-0.972 at τ= 1 mm. In preliminary benchtop comparative trials (one trial per condition), cervical aspiration catheter placement showed higher max-median ROI displacement and stress-proxy values than internal carotid artery terminus placement. Conclusion: The proposed protocol provides standardized, time-resolved surface kinematics and comparative relative displacement and stress proxy measurements for thrombectomy benchtop studies. The framework supports condition-to-condition comparisons and methods validation, while remaining distinct from absolute wall-stress estimation. Implementation code and example data are available at https://ethanuser.github.io/vessel4D

  • 5 authors
·
Apr 7

VQ-Seg: Vector-Quantized Token Perturbation for Semi-Supervised Medical Image Segmentation

Consistency learning with feature perturbation is a widely used strategy in semi-supervised medical image segmentation. However, many existing perturbation methods rely on dropout, and thus require a careful manual tuning of the dropout rate, which is a sensitive hyperparameter and often difficult to optimize and may lead to suboptimal regularization. To overcome this limitation, we propose VQ-Seg, the first approach to employ vector quantization (VQ) to discretize the feature space and introduce a novel and controllable Quantized Perturbation Module (QPM) that replaces dropout. Our QPM perturbs discrete representations by shuffling the spatial locations of codebook indices, enabling effective and controllable regularization. To mitigate potential information loss caused by quantization, we design a dual-branch architecture where the post-quantization feature space is shared by both image reconstruction and segmentation tasks. Moreover, we introduce a Post-VQ Feature Adapter (PFA) to incorporate guidance from a foundation model (FM), supplementing the high-level semantic information lost during quantization. Furthermore, we collect a large-scale Lung Cancer (LC) dataset comprising 828 CT scans annotated for central-type lung carcinoma. Extensive experiments on the LC dataset and other public benchmarks demonstrate the effectiveness of our method, which outperforms state-of-the-art approaches. Code available at: https://github.com/script-Yang/VQ-Seg.

  • 3 authors
·
Jan 15 2

Transformer-based Image Generation from Scene Graphs

Graph-structured scene descriptions can be efficiently used in generative models to control the composition of the generated image. Previous approaches are based on the combination of graph convolutional networks and adversarial methods for layout prediction and image generation, respectively. In this work, we show how employing multi-head attention to encode the graph information, as well as using a transformer-based model in the latent space for image generation can improve the quality of the sampled data, without the need to employ adversarial models with the subsequent advantage in terms of training stability. The proposed approach, specifically, is entirely based on transformer architectures both for encoding scene graphs into intermediate object layouts and for decoding these layouts into images, passing through a lower dimensional space learned by a vector-quantized variational autoencoder. Our approach shows an improved image quality with respect to state-of-the-art methods as well as a higher degree of diversity among multiple generations from the same scene graph. We evaluate our approach on three public datasets: Visual Genome, COCO, and CLEVR. We achieve an Inception Score of 13.7 and 12.8, and an FID of 52.3 and 60.3, on COCO and Visual Genome, respectively. We perform ablation studies on our contributions to assess the impact of each component. Code is available at https://github.com/perceivelab/trf-sg2im

  • 3 authors
·
Mar 8, 2023

Origin of the X-ray off-states in Vela X-1

Context: Vela X-1 is the prototype of the classical sgHMXB systems. Recent continuous and long monitoring campaigns revealed a large hard X-rays variability amplitude with strong flares and off-states. This activity has been interpreted invoking clumpy stellar winds and/or magnetic gating mechanisms. Aims: We are probing if the observed behaviour could be explained by unstable hydrodynamic flows close to the neutron star rather than the more exotic phenomena. Methods: We have used the hydrodynamic code VH-1 to simulate the flow of the stellar wind with high temporal resolution and to compare the predicted accretion rate with the observed light-curves. Results: The simulation results are similar to the observed variability. Off-states are predicted with a duration of 5 to 120 minutes corresponding to transient low density bubbles forming around the neutron star. Oscillations of the accretion rate with a typical period of sim 6800 sec are generated in our simulations and observed. They correspond to the complex motion of a bow shock, moving either towards or away from the neutron star. Flares are also produced by the simulations up to a level of 10^{37} erg/s. Conclusions: We have qualitatively reproduced the hard X-ray variations observed in Vela X-1 with hydrodynamic instabilities predicted by a simple model. More sophisticated phenomena, such as clumpy winds or the magnetic gating mechanism, are not excluded but not required to explain the basic phenomenology.

  • 2 authors
·
Dec 16, 2014

Curriculum-Driven 3D CT Report Generation via Language-Free Visual Grafting and Zone-Constrained Compression

Automated radiology report generation from 3D computed tomography (CT) volumes is challenging due to extreme sequence lengths, severe class imbalance, and the tendency of large language models (LLMs) to ignore visual tokens in favor of linguistic priors. We present Ker-VLJEPA-3B, a four-phase curriculum learning framework for free-text report generation from thoracic CT volumes. A phased training curriculum progressively adapts a Llama 3.2 3B decoder to ground its output in visual features from a frozen, self-supervised encoder. Our visual backbone (LeJEPA ViT-Large) is trained via self-supervised joint-embedding prediction on unlabeled CTs, without text supervision. Unlike contrastive models (CLIP, BiomedCLIP), this language-free backbone yields modality-pure representations. Vision-language alignment is deferred to the curriculum's bridge and generation phases. This modality-agnostic design can integrate any self-supervised encoder into an LLM without paired text during foundation training. Methodological innovations include: (1) zone-constrained cross-attention compressing slice embeddings into 32 spatially-grounded visual tokens; (2) PCA whitening of anisotropic LLM embeddings; (3) a positive-findings-only strategy eliminating posterior collapse; (4) warm bridge initialization transferring projection weights; and (5) selective cross-attention freezing with elastic weight consolidation to prevent catastrophic forgetting. Evaluated on the CT-RATE benchmark (2,984 validation volumes, 18 classes), Ker-VLJEPA-3B achieves a macro F1 of 0.429, surpassing the state-of-the-art (U-VLM, macro F1 = 0.414) by 3.6%, and reaching 0.448 (+8.2%) with threshold optimization. Ablation studies confirm 56.6% of generation quality derives from patient-specific visual content. Code and weights are available.

  • 4 authors
·
Mar 24

Induction Signatures Are Not Enough: A Matched-Compute Study of Load-Bearing Structure in In-Context Learning

Mechanism-targeted synthetic data is increasingly proposed as a way to steer pretraining toward desirable capabilities, but it remains unclear how such interventions should be evaluated. We study this question for in-context learning (ICL) under matched compute (iso-FLOPs) using Bi-Induct, a lightweight data rewrite that interleaves short directional copy snippets into a natural pretraining stream: forward-copy (induction), backward-copy (anti-induction, as a directional control), or a balanced mix. Across 0.13B-1B decoder-only models, we evaluate (i) few-shot performance on standard LM benchmarks and function-style ICL probes, (ii) head-level copy telemetry, and (iii) held-out perplexity as a guardrail. Bi-Induct reliably increases induction-head activity, but this does not translate into consistent improvements in few-shot generalization: on standard LM benchmarks, Bi-Induct is largely performance-neutral relative to natural-only training, while on function-style probes the 1B natural-only model performs best. Despite explicit backward-copy cues, anti-induction scores remain near zero across scales, revealing a strong forward/backward asymmetry. Targeted ablations show a sharper distinction: removing the top 2% induction heads per layer harms ICL more than matched random ablations, with the largest relative drop occurring in the natural-only models. This indicates that natural-only training produces more centralized, load-bearing induction circuitry, whereas Bi-Induct tends to create more distributed and redundant induction activity. Our main conclusion is that eliciting a mechanism is not the same as making it load-bearing. For data-centric foundation model design, this suggests that synthetic data interventions should be evaluated not only by signature amplification, but by whether they create causally necessary computation while preserving natural-data modeling quality.

  • 2 authors
·
Mar 13

Detection Is Cheap, Routing Is Learned: Why Refusal-Based Alignment Evaluation Fails

Current alignment evaluation mostly measures whether models encode dangerous concepts and whether they refuse harmful requests. Both miss the layer where alignment often operates: routing from concept detection to behavioral policy. We study political censorship in Chinese-origin language models as a natural experiment, using probes, surgical ablations, and behavioral tests across nine open-weight models from five labs. Three findings follow. First, probe accuracy alone is non-diagnostic: political probes, null controls, and permutation baselines can all reach 100%, so held-out category generalization is the informative test. Second, surgical ablation reveals lab-specific routing. Removing the political-sensitivity direction eliminates censorship and restores accurate factual output in most models tested, while one model confabulates because its architecture entangles factual knowledge with the censorship mechanism. Cross-model transfer fails, indicating that routing geometry is model- and lab-specific. Third, refusal is no longer the dominant censorship mechanism. Within one model family, hard refusal falls to zero while narrative steering rises to the maximum, making censorship invisible to refusal-only benchmarks. These results support a three-stage descriptive framework: detect, route, generate. Models often retain the relevant knowledge; alignment changes how that knowledge is expressed. Evaluations that audit only detection or refusal therefore miss the routing mechanism that most directly determines behavior.

  • 1 authors
·
Mar 18

NAS evaluation is frustratingly hard

Neural Architecture Search (NAS) is an exciting new field which promises to be as much as a game-changer as Convolutional Neural Networks were in 2012. Despite many great works leading to substantial improvements on a variety of tasks, comparison between different methods is still very much an open issue. While most algorithms are tested on the same datasets, there is no shared experimental protocol followed by all. As such, and due to the under-use of ablation studies, there is a lack of clarity regarding why certain methods are more effective than others. Our first contribution is a benchmark of 8 NAS methods on 5 datasets. To overcome the hurdle of comparing methods with different search spaces, we propose using a method's relative improvement over the randomly sampled average architecture, which effectively removes advantages arising from expertly engineered search spaces or training protocols. Surprisingly, we find that many NAS techniques struggle to significantly beat the average architecture baseline. We perform further experiments with the commonly used DARTS search space in order to understand the contribution of each component in the NAS pipeline. These experiments highlight that: (i) the use of tricks in the evaluation protocol has a predominant impact on the reported performance of architectures; (ii) the cell-based search space has a very narrow accuracy range, such that the seed has a considerable impact on architecture rankings; (iii) the hand-designed macro-structure (cells) is more important than the searched micro-structure (operations); and (iv) the depth-gap is a real phenomenon, evidenced by the change in rankings between 8 and 20 cell architectures. To conclude, we suggest best practices, that we hope will prove useful for the community and help mitigate current NAS pitfalls. The code used is available at https://github.com/antoyang/NAS-Benchmark.

  • 3 authors
·
Dec 28, 2019

AdverX-Ray: Ensuring X-Ray Integrity Through Frequency-Sensitive Adversarial VAEs

Ensuring the quality and integrity of medical images is crucial for maintaining diagnostic accuracy in deep learning-based Computer-Aided Diagnosis and Computer-Aided Detection (CAD) systems. Covariate shifts are subtle variations in the data distribution caused by different imaging devices or settings and can severely degrade model performance, similar to the effects of adversarial attacks. Therefore, it is vital to have a lightweight and fast method to assess the quality of these images prior to using CAD models. AdverX-Ray addresses this need by serving as an image-quality assessment layer, designed to detect covariate shifts effectively. This Adversarial Variational Autoencoder prioritizes the discriminator's role, using the suboptimal outputs of the generator as negative samples to fine-tune the discriminator's ability to identify high-frequency artifacts. Images generated by adversarial networks often exhibit severe high-frequency artifacts, guiding the discriminator to focus excessively on these components. This makes the discriminator ideal for this approach. Trained on patches from X-ray images of specific machine models, AdverX-Ray can evaluate whether a scan matches the training distribution, or if a scan from the same machine is captured under different settings. Extensive comparisons with various OOD detection methods show that AdverX-Ray significantly outperforms existing techniques, achieving a 96.2% average AUROC using only 64 random patches from an X-ray. Its lightweight and fast architecture makes it suitable for real-time applications, enhancing the reliability of medical imaging systems. The code and pretrained models are publicly available.

  • 5 authors
·
Feb 23, 2025

Surgical Refusal Ablation: Disentangling Safety from Intelligence via Concept-Guided Spectral Cleaning

Safety-aligned language models systematically refuse harmful requests. While activation steering can modulate refusal, ablating the raw "refusal vector" calculated from contrastive harmful and harmless prompts often causes collateral damage and distribution drift. We argue this degradation occurs because the raw vector is polysemantic, entangling the refusal signal with core capability circuits and linguistic style. We introduce Surgical Refusal Ablation (SRA) to distill these steering directions. SRA constructs a registry of independent Concept Atoms representing protected capabilities and stylistic confounds, then uses ridge-regularized spectral residualization to orthogonalize the refusal vector against these directions. This yields a clean refusal direction that targets refusal-relevant structure while minimizing disruption to the model's semantic geometry. Across five models (Qwen3-VL and Ministral series), SRA achieves deep refusal reduction (0-2%) with negligible perplexity impact on Wikitext-2 (mean delta PPL approx. 0.02) and minimal distribution drift. Notably, standard ablation on Qwen3-VL-4B induces severe drift (first-token KL = 2.088), whereas SRA maintains the original distribution (KL = 0.044) while achieving the same 0% refusal rate. Using teacher-forced perplexity on GSM8K and MBPP as a high-resolution capability proxy, we show SRA preserves math and code distributions. These results suggest that common "model damage" is often "Ghost Noise," defined as the spectral bleeding of the dirty refusal direction into capability subspaces.

  • 1 authors
·
Jan 12

Structured Spectral Graph Representation Learning for Multi-label Abnormality Analysis from 3D CT Scans

With the growing volume of CT examinations, there is an increasing demand for automated tools such as organ segmentation, abnormality detection, and report generation to support radiologists in managing their clinical workload. Multi-label classification of 3D Chest CT scans remains a critical yet challenging problem due to the complex spatial relationships inherent in volumetric data and the wide variability of abnormalities. Existing methods based on 3D convolutional neural networks struggle to capture long-range dependencies, while Vision Transformers often require extensive pre-training on large-scale, domain-specific datasets to perform competitively. In this work of academic research, we propose a 2.5D alternative by introducing a new graph-based framework that represents 3D CT volumes as structured graphs, where axial slice triplets serve as nodes processed through spectral graph convolution, enabling the model to reason over inter-slice dependencies while maintaining complexity compatible with clinical deployment. Our method, trained and evaluated on 3 datasets from independent institutions, achieves strong cross-dataset generalization, and shows competitive performance compared to state-of-the-art visual encoders. We further conduct comprehensive ablation studies to evaluate the impact of various aggregation strategies, edge-weighting schemes, and graph connectivity patterns. Additionally, we demonstrate the broader applicability of our approach through transfer experiments on automated radiology report generation and abdominal CT data.

  • 4 authors
·
Oct 12, 2025

CoTinyVLA: Chain-of-Thought Distillation for a Sub-Billion-Parameter Vision-Language-Action Model

Vision-Language-Action (VLA) models translate natural-language commands into robot action sequences, but leading systems on the LIBERO-Plus robustness benchmark use three- to seven-billion-parameter backbones whose memory demands can exceed embedded robotic budgets. We present CoTinyVLA, a 0.9B-parameter action model on a Qwen3.5-0.8B backbone that obtains that robustness by structuring supervision instead of enlarging the model. Three components target different axes of the problem: dual-view temporal input of 16 history frames per step with textual camera and time markers; hierarchical chain-of-thought (CoT) distillation from a 35B teacher into an episode-level Plan and a chunk-level Think span over task phase, gripper state and next subaction; and paraphrase augmentation expanding 40 base commands into 800 variants. On LIBERO-Plus, spanning 10,030 perturbed tasks across seven perturbation dimensions, CoTinyVLA reaches 90.8% on Spatial, 87.3% on Object, 86.6% on Goal and 80.7% on Long, leading the strongest 7B baseline on all four suites by 4.7, 2.8, 15.9 and 3.0 points, with every margin interval excluding zero. The gains concentrate on the hardest axes of the benchmark: across the eleven published baselines none exceeds 53.2% on Robot Initial States in any suite, whereas CoTinyVLA reaches 73.6% on Goal against 39.9% for the strongest baseline. Ablations show the three components to be separable by perturbation axis, and at a matched image budget how frames are divided between the two cameras and across time accounts for 8.6 points on its own. Closed-loop inference peaks at 2.25 GiB of allocated GPU memory, and paired interventions show the episode Plan to be load-bearing: replacing it with an empty or contradictory span costs 40 to 45 points of success. Structured supervision thus lets a 0.9B backbone exceed all of them. Code: https://github.com/BrainJellyPie/CoTinyVLA

  • 8 authors
·
Jul 27

SA-CycleGAN-2.5D: Self-Attention CycleGAN with Tri-Planar Context for Multi-Site MRI Harmonization

Multi-site neuroimaging analysis is fundamentally confounded by scanner-induced covariate shifts, where the marginal distribution of voxel intensities P(x) varies non-linearly across acquisition protocols while the conditional anatomy P(y|x) remains constant. This is particularly detrimental to radiomic reproducibility, where acquisition variance often exceeds biological pathology variance. Existing statistical harmonization methods (e.g., ComBat) operate in feature space, precluding spatial downstream tasks, while standard deep learning approaches are theoretically bounded by local effective receptive fields (ERF), failing to model the global intensity correlations characteristic of field-strength bias. We propose SA-CycleGAN-2.5D, a domain adaptation framework motivated by the HΔH-divergence bound of Ben-David et al., integrating three architectural innovations: (1) A 2.5D tri-planar manifold injection preserving through-plane gradients nabla_z at O(HW) complexity; (2) A U-ResNet generator with dense voxel-to-voxel self-attention, surpassing the O(L) receptive field limit of CNNs to model global scanner field biases; and (3) A spectrally-normalized discriminator constraining the Lipschitz constant (K_D le 1) for stable adversarial optimization. Evaluated on 654 glioma patients across two institutional domains (BraTS and UPenn-GBM), our method reduces Maximum Mean Discrepancy (MMD) by 99.1% (1.729 to 0.015) and degrades domain classifier accuracy to near-chance (59.7%). Ablation confirms that global attention is statistically essential (Cohen's d = 1.32, p < 0.001) for the harder heterogeneous-to-homogeneous translation direction. By bridging 2D efficiency and 3D consistency, our framework yields voxel-level harmonized images that preserve tumor pathophysiology, enabling reproducible multi-center radiomic analysis.

  • 2 authors
·
Mar 17

NEV-NCD: Negative Learning, Entropy, and Variance regularization based novel action categories discovery

Novel Categories Discovery (NCD) facilitates learning from a partially annotated label space and enables deep learning (DL) models to operate in an open-world setting by identifying and differentiating instances of novel classes based on the labeled data notions. One of the primary assumptions of NCD is that the novel label space is perfectly disjoint and can be equipartitioned, but it is rarely realized by most NCD approaches in practice. To better align with this assumption, we propose a novel single-stage joint optimization-based NCD method, Negative learning, Entropy, and Variance regularization NCD (NEV-NCD). We demonstrate the efficacy of NEV-NCD in previously unexplored NCD applications of video action recognition (VAR) with the public UCF101 dataset and a curated in-house partial action-space annotated multi-view video dataset. We perform a thorough ablation study by varying the composition of final joint loss and associated hyper-parameters. During our experiments with UCF101 and multi-view action dataset, NEV-NCD achieves ~ 83% classification accuracy in test instances of labeled data. NEV-NCD achieves ~ 70% clustering accuracy over unlabeled data outperforming both naive baselines (by ~ 40%) and state-of-the-art pseudo-labeling-based approaches (by ~ 3.5%) over both datasets. Further, we propose to incorporate optional view-invariant feature learning with the multiview dataset to identify novel categories from novel viewpoints. Our additional view-invariance constraint improves the discriminative accuracy for both known and unknown categories by ~ 10% for novel viewpoints.

  • 7 authors
·
Apr 14, 2023

The Muonic Portal to Vector Dark Matter:connecting precision muon physics, cosmology, and colliders

We present a comprehensive study of the Muonic Portal to Vector Dark Matter (MPVDM), a minimal yet phenomenologically rich extension of the Standard Model featuring a new SU(2)_D gauge symmetry and vector-like muons. In this framework the dark sector interacts with the Standard Model only through these heavy leptons, linking dark matter and the muon sector. The MPVDM can simultaneously explain the observed relic abundance and the muon anomalous magnetic moment a_mu under both the "tension" and "compatibility" scenarios motivated by recent (g-2)_mu results. A key finding is a generic off-resonance velocity suppression mechanism that allows light (<1 GeV) vector dark matter to evade CMB limits near 2*m_DM ~ m_H_D. Unlike scenarios based on ultra narrow Breit-Wigner resonances and early kinetic decoupling, the suppression follows from the temperature evolution of the annihilation cross section in a moderately detuned near resonant regime, where being 10-20 percent below resonance gives the required CMB era suppression without fine tuning. A five dimensional parameter scan shows that the tension scenario requires sub GeV dark matter with g_D ~ 1e-3 and TeV scale vector like muons, while the compatibility scenario admits a broad mass range up to multi TeV. Recasting ATLAS and CMS searches for mu+ mu- + E_T^miss sets a lower bound of about 850 GeV on vector like muons. The MPVDM thus offers a unified, predictive, and experimentally accessible framework linking dark matter and muon physics across cosmological and collider frontiers.

  • 4 authors
·
Oct 21, 2025

Visual Bridge: Universal Visual Perception Representations Generating

Recent advances in diffusion models have achieved remarkable success in isolated computer vision tasks such as text-to-image generation, depth estimation, and optical flow. However, these models are often restricted by a ``single-task-single-model'' paradigm, severely limiting their generalizability and scalability in multi-task scenarios. Motivated by the cross-domain generalization ability of large language models, we propose a universal visual perception framework based on flow matching that can generate diverse visual representations across multiple tasks. Our approach formulates the process as a universal flow-matching problem from image patch tokens to task-specific representations rather than an independent generation or regression problem. By leveraging a strong self-supervised foundation model as the anchor and introducing a multi-scale, circular task embedding mechanism, our method learns a universal velocity field to bridge the gap between heterogeneous tasks, supporting efficient and flexible representation transfer. Extensive experiments on classification, detection, segmentation, depth estimation, and image-text retrieval demonstrate that our model achieves competitive performance in both zero-shot and fine-tuned settings, outperforming prior generalist and several specialist models. Ablation studies further validate the robustness, scalability, and generalization of our framework. Our work marks a significant step towards general-purpose visual perception, providing a solid foundation for future research in universal vision modeling.

  • 7 authors
·
Nov 10, 2025

XOCT: Enhancing OCT to OCTA Translation via Cross-Dimensional Supervised Multi-Scale Feature Learning

Optical Coherence Tomography Angiography (OCTA) and its derived en-face projections provide high-resolution visualization of the retinal and choroidal vasculature, which is critical for the rapid and accurate diagnosis of retinal diseases. However, acquiring high-quality OCTA images is challenging due to motion sensitivity and the high costs associated with software modifications for conventional OCT devices. Moreover, current deep learning methods for OCT-to-OCTA translation often overlook the vascular differences across retinal layers and struggle to reconstruct the intricate, dense vascular details necessary for reliable diagnosis. To overcome these limitations, we propose XOCT, a novel deep learning framework that integrates Cross-Dimensional Supervision (CDS) with a Multi-Scale Feature Fusion (MSFF) network for layer-aware vascular reconstruction. Our CDS module leverages 2D layer-wise en-face projections, generated via segmentation-weighted z-axis averaging, as supervisory signals to compel the network to learn distinct representations for each retinal layer through fine-grained, targeted guidance. Meanwhile, the MSFF module enhances vessel delineation through multi-scale feature extraction combined with a channel reweighting strategy, effectively capturing vascular details at multiple spatial scales. Our experiments on the OCTA-500 dataset demonstrate XOCT's improvements, especially for the en-face projections which are significant for clinical evaluation of retinal pathologies, underscoring its potential to enhance OCTA accessibility, reliability, and diagnostic value for ophthalmic disease detection and monitoring. The code is available at https://github.com/uci-cbcl/XOCT.

  • 6 authors
·
Sep 9, 2025