ksanchez84/LUTSeg
Viewer β’ Updated β’ 171 β’ 2.92k β’ 2
Experimental wound tissue segmentation models exported to ONNX FP32 (opset 17) for lightweight CPU inference with ONNX Runtime.
V6-TwoStage (Recommended for Research / Demo):woundvision_v6_stage1_wound.onnx (54.66 MB) β Stage 1 U-Net ResNet18 Binary Wound Detector (320Γ320)woundvision_v6_stage2_tissue.onnx (93.22 MB) β Stage 2 U-Net ResNet34 ROI 6-Class Tissue Segmenter (320Γ320)V5-Augmented (Single-Stage, 100% CC BY 4.0 LUTSeg only):woundvision_v5_augmented.onnx (93.22 MB) β Single-stage U-Net ResNet34 (320Γ320)| Metric | V5-Augmented |
V6-TwoStage |
Delta |
|---|---|---|---|
| Pixel Accuracy | 90.54% |
92.19% |
+1.65% |
| Wound Dice (Binary) | 81.18% |
85.94% |
+4.76% |
| Clinical-3 Macro Dice (Slough / Granulation / Necrotic) | 59.45% |
64.04% |
+4.59% |
| Macro Tissue Dice (5 classes) | 43.16% |
47.04% |
+3.88% |
| Granulation Dice | 74.89% |
78.02% |
+3.13% |
| Necrotic Dice | 60.91% |
65.91% |
+5.00% |
| Slough Dice | 42.54% |
48.18% |
+5.64% |
| Epithelial Dice | 37.43% |
43.09% |
+5.66% |
| Normal Skin False Positive Rate | β | 0.0% |
β |
normal_*.png healthy skin hard negatives, Apache 2.0)Experimental research prototype. Not clinically validated, not a medical device, and not intended for diagnosis or clinical treatment decisions.