"01 CRACKS FISSURES": {"name":"Cracks and Fissures in Cladding","count":790,"severity":"Medium-High","priority":"P2","deadline":"1–3 months","risk":"Water ingress and possible structural degradation","recommendation":"Seal surface cracks with elastic mortar; use resin injection or structural stitching for structural cracks."},
"02 DAMPNESS DUE TO FILTRATION": {"name":"Dampness due to Filtration","count":271,"severity":"High","priority":"P2","deadline":"1–3 months","risk":"Water ingress and deterioration of finishes","recommendation":"Locate entry point, repair waterproofing, seal joints and apply water-repellent treatment."},
"03 EFFLORESCENCE": {"name":"Efflorescence","count":260,"severity":"Low-Medium","priority":"P3","deadline":"3–6 months","risk":"Aesthetic and superficial degradation","recommendation":"Dry brush, neutralize salts, waterproof affected area and remove moisture source."},
"04 CLADDING DETACHMENT": {"name":"Cladding Detachment","count":162,"severity":"High","priority":"P1","deadline":"Immediate","risk":"Falling fragments onto people or vehicles","recommendation":"Cordoning off, percussion inspection, removal of loose pieces and mechanical re-anchoring."},
"05 REBAR CORROSION": {"name":"Rebar Corrosion","count":598,"severity":"High","priority":"P1","deadline":"Immediate","risk":"Structural collapse and falling fragments","recommendation":"Urgent structural assessment, passivation of reinforcement and UNE-EN 1504 repair mortar."},
"06 CAPILLARY DAMP": {"name":"Capillary Dampness","count":555,"severity":"Medium","priority":"P2","deadline":"1–3 months","risk":"Material degradation and health issues","recommendation":"Inject hydrophobic chemical barrier, replace affected coating with breathable mortar and improve drainage."},
"07 CARBONATION": {"name":"Carbonation","count":182,"severity":"Medium-High","priority":"P2","deadline":"1–3 months","risk":"Reinforcement corrosion and structural loss","recommendation":"Test carbonation depth, apply protective coating and repair advanced areas according to UNE-EN 1504."},
"08 OXIDATION OF METALLIC ELEMENTS": {"name":"Oxidation of Metallic Elements","count":550,"severity":"Medium","priority":"P1/P2","deadline":"1–3 months","risk":"Falling elements and facade staining","recommendation":"Brush or sandblast rust, apply anti-rust primer and replace elements with section loss."},
"09 BIOLOGICAL GROWTH": {"name":"Biological Colonization","count":708,"severity":"Low-Medium","priority":"P3","deadline":"3–6 months","risk":"Support degradation and aesthetic damage","recommendation":"Clean with water/steam, apply approved biocide and hydrophobic treatment."},
"10 JOINT SEALING FAILURE": {"name":"Joint Sealing Failure","count":119,"severity":"High","priority":"P2","deadline":"1–3 months","risk":"Water ingress and interior deterioration","recommendation":"Remove deteriorated sealant, clean substrate and apply new elastic sealant with primer/backer rod."},
"11 BULGING OF THE LINING": {"name":"Bulging of the Lining","count":251,"severity":"High","priority":"P1","deadline":"Immediate","risk":"Falling materials onto people","recommendation":"Cordoning off, remove areas at risk and replace cladding with compatible mortar."},
"12 DETERIORATION ELEMENTS OF CORONATION": {"name":"Deterioration of Coronation Elements","count":487,"severity":"High","priority":"P1","deadline":"Immediate","risk":"Falling fragments and water ingress","recommendation":"Inspect from scaffolding, consolidate/replace damaged parts and waterproof coping/drip edge."},
"13 DETERIORATION OF EXTERIOR WOODWORK": {"name":"Deterioration of Exterior Woodwork","count":138,"severity":"Medium","priority":"P2","deadline":"1–3 months","risk":"Water ingress and loss of functionality","recommendation":"Repair or replace damaged frames, seals and hardware; restore protective coating."},
"14 STAINS AND GENERAL SOILING": {"name":"Stains and General Soiling","count":313,"severity":"Low","priority":"P3","deadline":"3–6 months","risk":"Aesthetic degradation and urban image impact","recommendation":"Clean with pressure water, steam, gentle blasting or surface-specific cleaning products."},
"15 EROSION AND DISINTEGRATION OF MORTARS": {"name":"Erosion and Disintegration of Mortars","count":243,"severity":"Medium","priority":"P2","deadline":"1–3 months","risk":"Water ingress and support loss","recommendation":"Remove deteriorated mortar, consolidate substrate and repoint with compatible breathable mortar."},
"16 CORNICE DETACHMENT": {"name":"Cornice Detachment","count":247,"severity":"High","priority":"P1","deadline":"Immediate","risk":"Falling onto people and vehicles","recommendation":"Urgent cordoning off, scaffold inspection, dismantle at-risk parts and reinstall with stainless anchors."},
"17 BREAKAGE OR DETERIORATION OF DOWNPIPES AND GUTTERS": {"name":"Breakage or Deterioration of Downpipes and Gutters","count":106,"severity":"Medium-High","priority":"P2","deadline":"1–3 months","risk":"Water ingress and facade deterioration","recommendation":"Clean gutters, replace damaged sections, retighten clamps and check slopes/joints."},
"21 DIRT FROM RUNOFF": {"name":"Dirt from Runoff","count":84,"severity":"Low","priority":"P3","deadline":"3–6 months","risk":"Aesthetic degradation","recommendation":"Clean surface and correct runoff paths using drip edges or water-repellent treatment."},
"22 SURFACE CONDENSATION ON FACADE": {"name":"Surface Condensation on Facade","count":165,"severity":"Low-Medium","priority":"P3","deadline":"3–6 months","risk":"Moisture staining, mold and superficial degradation","recommendation":"Improve ventilation/thermal conditions and clean biological or moisture-related deposits."},
"23 DETACHMENT OF CLADDING NATURAL STONE": {"name":"Detachment of Natural Stone Cladding","count":212,"severity":"High","priority":"P1","deadline":"Immediate","risk":"Falling stone pieces and public safety risk","recommendation":"Cordoning off, inspect anchors, remove unstable slabs and reinstall with mechanical safety anchors."},
"24 PAINT DETERIORATION": {"name":"Paint Deterioration","count":351,"severity":"Low-Medium","priority":"P3","deadline":"3–6 months","risk":"Loss of protection and aesthetic degradation","recommendation":"Remove loose paint, prepare substrate and repaint with compatible exterior coating."},
"25 GLASS BREAKAGE": {"name":"Glass Breakage","count":249,"severity":"High","priority":"P1","deadline":"Immediate","risk":"Falling glass and injury risk","recommendation":"Cordoning off, remove broken glass and replace with compliant safety glazing."}
}