Spaces:
Running
Download DOCS.md from Shubhambhandari/Pathify: direct link, hf CLI and curl.
- Browser
- Download file 13.5 kB
-
https://huggingface.co/spaces/Shubhambhandari/Pathify/resolve/main/DOCS.md
- Command line
-
hf download hf://spaces/Shubhambhandari/Pathify/DOCS.md
-
curl -L -o DOCS.md https://huggingface.co/spaces/Shubhambhandari/Pathify/resolve/main/DOCS.md
PathQA β an AI second-reader QA safety-net for pathology labs
Positioning: quality assurance / workflow, not diagnosis. PathQA never issues a diagnosis and never changes a pathologist's sign-out. It runs quietly behind the sign-out and does exactly one thing: when it confidently disagrees with the pathologist, it raises a hand β "case N, worth a second look, here's why." A human decides. The pathologist stays in control.
This repo is the v1 build, in two stages exactly as scoped:
- Patch-classifier demo on public data (PatchCamelyon) β proves the model + the QA logic end-to-end.
- Train-on-your-data version β the model comes to the lab's own labeled slides, which is what fixes domain shift, and nothing leaves the machine.
Why this design (the three product requirements)
1. Trains on the lab's own labeled slides β solves domain shift + keeps data private.
Off-the-shelf histopathology models degrade badly across stains, scanners and
tissue mixes. train_on_your_data.py fine-tunes on a folder of the lab's own
patches, so the model learns that lab's distribution. All I/O is local β the
model comes to the data.
2. Flags only disagreements β a human re-checks.
The QA engine (pathqa/qa.py) compares the model's read to the pathologist's
label and flags a case only when the model disagrees and is confident
(confidence β₯ tau). Everything else passes untouched. Output is a prioritized
re-check worklist, sorted by confidence β the queue a pathologist actually opens.
3. Assist, not replace. No case is ever auto-relabeled. The only output is a "recommend re-review" flag with a plain-language reason. Every artifact carries that reminder.
Two extra design choices that matter for a QA tool specifically:
- Calibration. A QA threshold is only meaningful if "0.9 confidence" behaves like 0.9. Raw softmax is over-confident, so I apply temperature scaling (Guo et al., 2017) on the validation split. In the smoke test this dropped validation loss from 0.265 β 0.231.
- Workload budget. Instead of a fixed
tau, a lab can say "flag the top 5% most-confident disagreements" (--budget 0.05) so the QA queue fits the time the lab actually has. The engine backs out the effectivetaufor you.
Layout
pathqa/
pathqa-app / .bat # ONE-COMMAND LAUNCHER (venv + deps + open browser)
pathqa/
model.py # ResNet18/34 binary tumor/normal head + TemperatureScaler
data.py # 3 sources: PatchCamelyon | your ImageFolder | synthetic (tests)
engine.py # train / evaluate (AUROC, ECE) / temperature fitting
qa.py # SecondReader β patch-level disagreement + flagging engine
wsi.py # whole-slide tiling + tissue detection
slide.py # slide aggregation (top-K), slide-level QA, heatmap
gradcam.py # Grad-CAM explainer (why the model flagged it)
cli.py # `pathqa serve|demo|slide-demo|train` dispatcher
backend/ # stdlib HTTP server + stateful QA session
frontend/ # single-file React UI (Patch QA + Whole-slide QA tabs)
demo.py # patch QA demo (stage 1)
slide_demo.py # whole-slide QA demo
train_on_your_data.py # fine-tune on the lab's own labeled patches (stage 2)
train_pcam.py # real PatchCamelyon training + AUROC/ECE
requirements.txt
Install
pip install -r requirements.txt # torch, torchvision, h5py
Run β Stage 1: patch-classifier demo
No download, verifies the whole pipeline in ~1 minute on CPU:
python demo.py --synthetic --epochs 1 --no-pretrained
Real public data (downloads PatchCamelyon on first run; use a GPU or Colab):
python demo.py --pcam --subset 20000 --epochs 3 --budget 0.05
What it does: loads patches β fine-tunes ResNet18 β temperature-calibrates β
simulates a sign-out queue with a small injected human-error rate β runs the QA
second reader β prints a report and writes qa_out/worklist.csv +
qa_out/qa_report.json.
Sample output:
PathQA second-reader report
cases reviewed : 128
model/pathologist disagreements: 17 (13.3%)
flagged for re-check : 6 (4.7%) at confidence >= 0.85
-> 122 cases pass QA untouched; pathologist reviews only the 6 flagged.
[QA effectiveness] of 17 simulated sign-out errors, the second reader flagged 6 for re-check.
Run β Stage 2: train on your data
Lay your labeled patches out as:
my_lab_data/
train/normal/*.png train/tumor/*.png
val/normal/*.png val/tumor/*.png
python train_on_your_data.py --data my_lab_data --epochs 5 --out model.pt
Saves the fine-tuned weights and the fitted temperature, so the QA engine gets calibrated confidences out of the box. Everything stays on the machine.
Run β the local app (one command)
A local, on-prem app so a pathologist (non-coder) can use it. The backend is Python stdlib only (no framework to install, nothing phones home β chosen for an air-gapped lab), and the frontend is a single-file React UI it serves.
./pathqa-app # macOS/Linux β makes a venv, installs deps, opens the browser
pathqa-app.bat # Windows
./pathqa-app demo # patch QA demo (headless)
./pathqa-app slide-demo # whole-slide QA demo (headless)
./pathqa-app train --help
The launcher creates a .venv, installs requirements.txt, then starts the
server and opens http://127.0.0.1:8000 (localhost only). Under the hood it
calls pathqa/cli.py; you can also run the pieces directly:
PYTHONPATH=. python backend/server.py --open
Out of the box it fine-tunes a small demo model on synthetic patches so there's a working worklist immediately. To serve a model you trained on your own data:
PATHQA_MODEL=model.pt PYTHONPATH=. python backend/server.py
What the UI does: shows the flagged re-check queue (patch thumbnail, sign-out vs
model read, confidence), a live Ο slider to tune the queue length, and two
actions per case β Confirm sign-out or Amend (model was right). Every
decision is appended to audit_log.jsonl with model read, confidence and a note
β the governance trail. No sign-out is ever changed automatically.
API (stable; maps 1:1 onto FastAPI path operations if you later swap frameworks):
GET /api/summary, GET /api/worklist, GET /api/patch/{id}.png,
POST /api/decision, POST /api/settings.
Air-gapped frontend: run frontend/vendor_offline.sh once to pull React+Babel
locally, then point the three <script> tags in index.html at ./vendor/....
Whole-slide QA (patch β slide)
A real sign-out is per-slide, not per-patch. The whole-slide layer tiles a slide, scores every tissue tile, and aggregates into one slide-level decision:
pathqa/wsi.pyβ tiling + tissue/background detection (keeps stained tissue, drops glass). Opens large PIL images, true WSI via OpenSlide (.svs/.ndpi, optional lazy import), or a synthetic slide for the demo.pathqa/slide.pyβ top-K mean pooling: a slide is called tumor if its most suspicious regions are tumor (matches metastasis detection β one focus is enough β far better than averaging tumor away across a big slide). Also emits a tumor-probability heatmap and the slide-level QA flags.
Run the slide demo (synthetic cohort, writes a heatmap per slide + a worklist):
python slide_demo.py --n-slides 8 --tau 0.7 --outdir slide_out
For a real slide, swap SyntheticSlide for open_slide_image("case.svs") β the
rest is unchanged. OpenSlide is only needed for native WSI formats:
pip install openslide-python (plus the system OpenSlide library).
In the app, the Whole-slide QA tab shows each flagged slide as a heatmap card
(sign-out vs model, slide score, suspicious-tile count) with Confirm / Amend, and
its own Ο slider. Slide decisions log to the same audit_log.jsonl with
"level":"slide".
Analyze an image (real model + stain), and the train-better loop
The app's "Analyze image" tab runs an uploaded H&E image through BOTH methods and combines them:
- the trained CNN (
pathqa/infer.py) with test-time augmentation, giving a calibrated tumour probability plus an uncertainty estimate (so it can say "not sure" instead of guessing), and a Grad-CAM overlay (patch) or a tiled tumour heatmap with the top suspicious tiles (slide); - the stain/colour method (dense-nuclei density) as an independent check.
The two are merged into one verdict: if they agree, confidence goes up; if they disagree, it returns "needs review" rather than a false certainty.
Endpoints: POST /api/analyze-image (base64 image in, verdict plus two overlay
images out), POST /api/feedback (save a labelled image as training data),
GET /api/feedback/stats.
Train-better loop: every image you label in the app is saved under
data/feedback/{normal,tumor}/. When you have enough, fine-tune on exactly the
cases your lab sees:
python finetune_from_feedback.py --base pcam_model.pt --out pcam_model.pt
# prints held-out AUROC + ECE, saves a calibrated checkpoint the app loads
PATHQA_MODEL=pcam_model.pt ./pathqa-app
So it gets better the more it is used, and always reports honest metrics before you adopt a new checkpoint.
Explainability β Grad-CAM
A flag is only actionable if the pathologist can see why the model disagreed.
pathqa/gradcam.py runs Grad-CAM on the classifier's last conv block and
overlays a heat map on the patch showing which pixels drove the call. In the
app, clicking a flagged patch opens the patch next to its "model attention"
overlay. This is explanation, not diagnosis β it never changes a call.
Real training on PatchCamelyon
train_pcam.py trains on real PCam and reports honest held-out metrics β AUROC
and Expected Calibration Error (ECE) before/after temperature scaling β then
saves an app-ready checkpoint.
# GPU (full run)
python train_pcam.py --epochs 5 --batch-size 256 --out pcam_model.pt
# quick CPU subset
python train_pcam.py --subset 8000 --epochs 1 --batch-size 64 --out pcam_model.pt
# pipeline check, no download
python train_pcam.py --synthetic --no-pretrained --epochs 1 --out demo_model.pt
Colab (free GPU) β PCam is ~7 GB so run it there or on a lab GPU box:
!pip -q install torch torchvision h5py
!python train_pcam.py --epochs 5 --batch-size 256 --out pcam_model.pt
It prints something like AUROC: 0.96 Β· ECE: 0.08 β 0.02 (calibrated). Then:
PATHQA_MODEL=pcam_model.pt ./pathqa-app # the app now uses your real model
Note: full PCam training needs a GPU and the ~7 GB download; the synthetic
--synthetic path exists to verify the training/metrics/calibration code runs
end-to-end without either. The pipeline was verified this way (AUROC/ECE/
checkpoint all produced correctly); real clinical numbers come from your run.
Key parameters
| Flag | Meaning |
|---|---|
--tau 0.9 |
Flag disagreements at/above this confidence. |
--budget 0.05 |
Instead of tau, flag only the top 5% most-confident disagreements (fits a workload). |
--path-error-rate |
(demo only) simulated pathologist error rate, to show the safety-net catching misses. |
--subset / --syn-train |
Cap dataset size for CPU-friendly runs. |
tau is the single most important dial. Lower it β catch more true misses but a
longer re-check queue; raise it β shorter queue but you may miss borderline
errors. Tune it against the lab's tolerated false-flag rate on a labeled
holdout, then re-check monthly.
What was verified
Ran end-to-end on CPU (ARM64): training converges, temperature calibration
lowers validation loss, both threshold and workload-budget flagging modes
produce a correct prioritized worklist, and the JSON report round-trips. The
real-data path uses the same code with --pcam or --data.
Roadmap (v2+, out of scope for this build)
- Slide-level, not just patch-level: tile a whole-slide image, aggregate patch scores into a slide decision, and flag at the slide level.
- Uncertainty on top of calibration: MC-dropout / deep ensembles to separate "confident disagreement" from "model has no idea."
- Active learning loop: feed re-checked flags back as new labels so the model improves on the lab's hard cases over time.
- Human factors: a viewer that jumps to the flagged region with a heatmap (Grad-CAM) so re-review takes seconds.
- Governance: audit log of every flag + outcome, and drift monitoring on the incoming slide distribution.
Regulatory framing (important, not legal advice)
Framing PathQA as an internal QA / workflow tool that only surfaces cases for human re-review β never rendering or altering a diagnosis β is a deliberately conservative posture. Anything that outputs a diagnosis is a different, much heavier regulatory category. Keep the "assist, not replace, human-in-the-loop" boundary bright, and involve regulatory/clinical governance before any use on real patient material. I'm not a lawyer or a regulatory advisor; validate the intended-use claim with someone who is.
Limitations
Binary tumor/normal patches only; no whole-slide aggregation yet; PatchCamelyon is lymph-node metastasis and is not representative of your tissue types β the public-data demo proves the mechanism, not clinical performance. Clinical performance must be established on your own validated data.