Real Battery Dataset Status
Summary
Fake/Sample Data: β DELETED
Real Data Downloaded:
β NASA Datasets (COMPLETED)
- Source: https://github.com/huzaifi18/RUL_prediction
- Files Downloaded: 6 CSV files (charge and discharge for B0005, B0006, B0007)
- Location:
data/nasa/ - Converted Files: 3 files in standard format
- Location:
data/nasa_converted/ - Format: β Converted to standard format (cycle_index, voltage, current, temperature, capacity)
- Files:
- B0005.csv (168 cycles, 13 KB)
- B0006.csv (168 cycles, 13 KB)
- B0007.csv (168 cycles, 13 KB)
β Stanford Datasets (COMPLETED)
- Source: https://github.com/petermattia/revisit-severson-et-al
- Files Downloaded: 41 CSV files (cell1.csv through cell41.csv)
- Location:
data/stanford/ - Total Size: ~30 MB
- Format: β οΈ DIFFERENT FORMAT - Matrix format (99 columns, appears to be voltage arrays)
- Note: Structure needs verification - columns are numeric values, not cycle_index/voltage/current/temperature/capacity
βΈοΈ CALCE Datasets (PENDING)
- Source: https://ioft-data.engin.umich.edu/calce-battery-datasets/
- Status: Requires manual download from IoFT mirror
- Format: CSV/text files
- Action Needed: Manual download required
π Zenodo Datasets (ANALYZED - RECOMMENDATION PROVIDED)
Dataset: Lithium-ion battery degradation: comprehensive cycle ageing data and analysis for commercial 21700 cells
Total Size: 49.4 GB
Zenodo Link: https://zenodo.org/records/10637334
Available Files:
experiment_metadata.xlsx (21.9 KB)
- Status: β RECOMMENDED FIRST
- Reason: Small metadata file - check structure before downloading large files
Expt 5 - Standard Cycle Aging (Control).zip (11.4 GB)
- Status: β β BEST CHOICE - RECOMMENDED
- Reason: Standard cycling conditions, control baseline, most general purpose
- Priority: 1
Expt 4 - Drive Cycle Aging (Control).zip (11.4 GB)
- Status: β GOOD CHOICE - RECOMMENDED
- Reason: Realistic drive cycles, control conditions
- Priority: 2
Expt 3 - Cathode Degradation and Li-Plating.zip (12.0 GB)
- Status: β οΈ NOT RECOMMENDED INITIALLY
- Reason: Specific degradation mode (cathode degradation, Li-plating)
- Use: Specialized analysis only
Expt 2 - C-based Degradation 2.zip (6.5 GB)
- Status: β οΈ NOT RECOMMENDED INITIALLY
- Reason: Specific chemistry (C-based)
- Use: Specialized analysis only
Expt 1 - Si-based Degradation.zip (9.1 GB)
- Status: β οΈ NOT RECOMMENDED INITIALLY
- Reason: Specific chemistry (Si-based)
- Use: Specialized analysis only
Recommended Download Strategy:
- First: Download
experiment_metadata.xlsx(21.9 KB) to understand data structure - Priority 1: Download
Expt 5 - Standard Cycle Aging (Control).zip(11.4 GB) - Priority 2 (Optional): Download
Expt 4 - Drive Cycle Aging (Control).zip(11.4 GB) - Skip initially: Expt 1-3 (too specific, save for later analysis)
Data Format Requirements
Our model expects CSV files with columns:
cycle_index: Cycle numbervoltage: Battery voltage (V)current: Battery current (A)temperature: Battery temperature (Β°C)capacity: Battery capacity (Ah)
Current Data Status
| Dataset | Status | Files | Format Match | Ready to Use |
|---|---|---|---|---|
| NASA (converted) | β Downloaded & Converted | 3 files | β Yes | β Yes |
| Stanford | β Downloaded | 41 files | β οΈ No (different format) | βΈοΈ Needs conversion |
| CALCE | βΈοΈ Not downloaded | - | - | - |
| Zenodo | π Analyzed | 0 files | - | - |