The record

Every test we ran.

The story follows one patient. This page is everything behind it: how the system is built, each experiment and what it found, the results as charts, the decisions taken along the way, every answered case, and the limits.

01 · Overview

What was built

A pipeline of five parts. Each one is tested on its own, then all together on patients none of it had seen.

  1. Core and penumbraAn nnU-Net, trained five times on different folds of ISLES'24, outlines the tissue already lost. Tissue at risk is the guideline's own rule: Tmax over 6 seconds.
  2. Bleed checkA ResNet-50 trained on RSNA scans reads the plain CT for any bleed, which rules out the clot-busting drug.
  3. The rulebookThe 2026 guideline rewritten in the team's own words as 47 passages, and a program that applies them to a case.
  4. The reasonerA language model reads the scan's numbers, a triage note and the whole rulebook, and decides on each treatment with cited reasons.
  5. The verifierEvery answer is split into claims, and each claim is traced to the scan, the note or a passage. What does not trace is a hallucination.

02 · Vision

The two vision models

What the language model is told about a scan comes from these two models, so their errors matter downstream.

Vision A: outlining the core

How often the core lands on the wrong side of a cut-off

Volumes matter more than outlines: the rules cut at 21, 31, 51 and 70 mL.

Vision B: the bleed check

03 · Results

The results, as charts

Hallucination rates are the verifier's, and the human check below shows they are upper bounds: people confirmed 18 of its 54 flags. The comparison between models holds. Hover or tap any mark; every chart has its numbers as a table.

04 · Experiments

Every experiment

Each numbered experiment, what it asked, how it was run and what it found, grouped by the part of the system it tested.

Loading the record…

05 · Decisions

The decisions behind it

Choices fixed along the way, so that results could not be tuned after the fact.

06 · Cases

Read every answer

Every answer here was produced earlier with the same prompt and verifier. Click any claim to light up what it rests on: a number in the imaging contract, a line of the note, or a rulebook passage. Claims the verifier flagged are marked ✕ flagged with the reason.

Pick a case on the left.

07 · Limits and credit

Limits and credit

What it is not

A research prototype built for a university course. It is not a medical device, has not been validated clinically, and must never be used to decide anyone's treatment. The rulebook is the team's reading of the guideline and has not been reviewed by a clinician.

Limits we report

  • The "core" is a model trained on final infarct, not acute core, in a cohort that was reperfused.
  • Real cases have no ASPECTS and mostly an unknown occlusion site, so the rules leave many decisions undetermined.
  • The bleed detector flags about half of ISLES'24's presumed bleed-free scans: a domain shift, not an RSNA failure.
  • Hallucination rates are the verifier's; humans confirmed about a third of its flags.

Data and credit

  • ISLES'24 (Zenodo 17652035), CC BY-NC-SA 4.0: Riedel et al., ISLES'24 – A Real-World Longitudinal Multimodal Stroke Dataset, arXiv:2408.11142; de la Rosa et al., arXiv:2408.10966. Cases are shown by alias only. This site is shared under the same licence.