Spaces:
Sleeping
Sleeping
| profile: City of Calgary SWMR | |
| source_manual: | |
| title: City of Calgary Stormwater Management & Design Manual | |
| edition: 2011 | |
| status: historical_baseline_verify_current_amendments | |
| criteria: | |
| trap_low_max_depth_m: 0.50 | |
| entrance_grade_margin_m: 0.30 | |
| conduit_capacity_review_ratio: 0.80 | |
| conduit_capacity_warning_ratio: 0.95 | |
| pipe_advisory_velocity_mps: 3.0 | |
| pipe_critical_velocity_mps: 4.0 | |
| continuity_review_pct: 0.50 | |
| continuity_warning_pct: 1.00 | |
| depth_velocity_curve: | |
| - [0.5, 0.80] | |
| - [1.0, 0.32] | |
| - [2.0, 0.21] | |
| - [3.0, 0.09] | |
| notes: | |
| - Project-specific SMDP, MDP, pond report, City direction, and current amendments take precedence. | |
| - Values marked as screening criteria are not automatic compliance limits. | |