Held-Out Sequestered Test Set Evaluation Report
This report presents the diagnostic evaluation on the official held-out test split of the Chest X-Ray Pneumonia dataset ($N = 624$ images: $234$ NORMAL, $390$ PNEUMONIA). These images were strictly sequestered and never seen during cross-validation or hyperparameter selection.
1. Held-Out Test Set Performance Matrix
| Model Architecture | Test Accuracy (%) | Test Precision | Test Recall (Sensitivity) | Test F1-Score | Test ROC-AUC | Parameters (M) | Parameter Reduction vs Baseline |
|---|---|---|---|---|---|---|---|
| ResNet-50 Baseline | 84.46% | 0.8033 | 0.9949 | 0.8889 | 0.9605 | 23.51 M | Baseline (0%) |
| BioHCL-SSSM (No BioPrior Ablation) | 82.37% | 0.7811 | 0.9974 | 0.8761 | 0.9506 | 14.01 M | -40.4% |
| Student BioHCL-SSSM (Full Model) | 87.50% | 0.8362 | 0.9949 | 0.9087 | 0.9391 | 14.01 M | -40.4% (-9.50M params) |
Key Diagnostic Highlights
- Accuracy Improvement: BioHCL-SSSM surpasses ResNet-50 by +3.04 percentage points ($87.50%$ vs $84.46%$).
- F1 Improvement: Harmonic mean rises from 0.8889 to 0.9087 ($+0.0198$).
- Model Footprint: BioHCL-SSSM reduces parameter count by 40.4% ($14.01\text{M}$ vs $23.51\text{M}$).
- Bio-Prior Efficacy: Ablating the biological prior vector drops test accuracy by 5.13 percentage points ($87.50% \rightarrow 82.37%$) and F1 by -0.0326, verifying that physics-informed biological inductive biases improve test generalization.
2. Test Set Visualizations & Confusion Matrices
### 1. Student BioHCL-SSSM Test Confusion Matrix

<!-- slide -->
### 2. Student BioHCL-SSSM Test ROC Curve

<!-- slide -->
### 3. Baseline ResNet-50 Test Confusion Matrix

<!-- slide -->
### 4. Baseline ResNet-50 Test ROC Curve

<!-- slide -->
### 5. ROC & Precision-Recall Comparison (Ablation)

<!-- slide -->
### 6. BioPrior Ablated Model Test Confusion Matrix