Download docs/limitations.md from approchin/sonic-pm01: direct link, hf CLI and curl.
- Browser
- Download file 3.4 kB
-
https://huggingface.co/approchin/sonic-pm01/resolve/main/docs/limitations.md
- Command line
-
hf download hf://approchin/sonic-pm01/docs/limitations.md
-
curl -L -o limitations.md https://huggingface.co/approchin/sonic-pm01/resolve/main/docs/limitations.md
Limitations and responsible use
These materials describe selected PM01 simulation experiments, not a general-purpose robot-control product. No real-robot execution, disturbance recovery, safety-certified operation, object manipulation, or production readiness is established. Fixed-start tracking does not establish safe entry, continuous switching, standing recovery, fault handling or emergency stop.
What the numbers do and do not show
- Completion means that the complete reference was observed without crossing the stated threshold. It is not pose accuracy. Joint, local/global body, root position and orientation errors need to accompany completion.
- The 4,000-step results use a single seed, one rollout per clip and reference-frame initialization. Failures remain in each denominator. For failed clips, error summaries contain the actual executed prefix only; the unexecuted suffix is not simulated or fabricated.
- The mixed 500 and BONES 500 use recorded sources held out from PM01 target-adaptation training. They are not newly blinded tests: these populations had been evaluated previously. SONIC pretraining exposure to the underlying sources is unknown.
- The mixed cohort is a selected, reference-qualified 106 LAFAN1 plus 394 OMOMO clips. Its LAFAN1 windows share 26 synchronous recording groups. The BONES test contains 500 held-out recordings selected from 1,209 candidates, but 431/500 clips share an action-family label with the adaptation set. The quality-conditioned OMOMO 500 is not a random sample of all OMOMO; 272 of its source sequences also occur in the mixed cohort.
- Source-derived action and difficulty labels are engineering annotations. A source label such as jump does not establish that the simulated PM01 became airborne. Saved trajectories lack measured contact forces; a foot-geometry diagnostic alone is not a force measurement.
- OMOMO is used for body tracking without the object dynamics or object load. A successful rollout is not a successful manipulation task.
- The local 0.8-rad primary and 0.8-rad² secondary orientation interpretations are reported separately. The selected datasets, morphology, simulator and tracked points differ from the authors' undisclosed Any2Any evaluation. No cross-paper efficiency or equal-performance claim follows from GPU-hour ratios.
- A separately initiated review of the new 4,000-step trajectories returned WARN for scope and uses same-family, provisional review. It supports the reported bounded measurements, not unqualified generalization.
Motion-data and model rights
Motion Data by Bones Studio. The project owner has identified the intended use as qualifying academic/non-commercial research. Under the applicable BONES/SEED terms, that confirmed use can include public display of results, subject to the licence and attribution conditions; raw motion data must not be made accessible. This project-specific eligibility does not grant downstream users blanket commercial or redistribution permission.
LAFAN1 and OMOMO contribute separate aggregate evaluation results. Their motion data are governed by their source terms. See Licences and attribution.
The release contains inference-only Actor exports. The code consumes packed observations and returns raw action means. Robot integration requires a separately validated interface and safety process.