ICSMA-24-023-01
Orthanc Osimis DICOM Web Viewer
A XSS payload can be uploaded as a DICOM study and when a user tries to view the infected study inside the Osimis WebViewer the XSS vulnerability gets triggered. If exploited, the attacker will be able to execute arbitrary JavaScript code inside the victim's browser.
[]
null
7.1
null
null
ICSMA-17-250-02A
Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities (Update A)
A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017...
[]
null
null
3.7
null
ICSA-20-252-05
Siemens Siveillance Video Client
In environments where Windows NTLM authentication is enabled the affected client application transmits usernames to the server in cleartext. This could allow an attacker in a privileged network position to obtain valid adminstrator login names and use this information to launch further attacks.
[]
null
5.3
null
null
ICSA-22-347-02
Schneider Electric APC Easy UPS Online
Schneider Electric APC Easy UPS Online versions 2.5-GA and prior are missing authentication for the updatePassword endpoint implemented in the LoginAction.updatePassword method. An unauthenticated user could exploit this vulnerability to modify administrator passwords.CVE-2022-42970 has been assigned to this vulnerabil...
[]
null
null
7.8
null
ICSA-22-132-14
Siemens Simcenter Femap
The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)
[]
null
7.8
null
null
ICSA-20-163-01
OSIsoft PI Web API 2019
The affected product is vulnerable to a cross-site scripting attack, which may allow an attacker to remotely execute arbitrary code.CVE-2020-12021 has been assigned to this vulnerability. A CVSS v3 base score of 7.7 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:N).
[]
null
null
7.7
null
ICSA-19-134-05
Siemens SINAMICS PERFECT HARMONY GH180 Drives NXG I and NXG II
A denial of service vulnerability exists in the affected products. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the affected system. At ...
[]
null
null
7.5
null
ICSA-23-341-06
Sierra Wireless AirLink with ALEOS firmware
Loop with Unreachable Exit Condition ('Infinite Loop') vulnerability in Sierra Wireless, Inc ALEOS could potentially allow a remote attacker to trigger a Denial of Service (DoS) condition for ACEManager without impairing other router functions. This condition is cleared by restarting the device. The ACEManager componen...
[]
null
8.1
null
null
ICSA-22-263-02
Hitachi Energy AFF660/665 Series
An improper parsing of URL arguments allows an attacker to exploit this vulnerability by crafting specially formed HTTP requests to overflow an internal buffer. Successful exploitation could cause a full compromise of the device.CVE-2020-6994 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been...
[]
null
null
9.8
null
ICSA-21-103-15
Siemens and Milestone Siveillance Video Open Network Bridge
Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server.
[]
null
9.9
null
null
ICSA-23-250-02
Phoenix Contact TC ROUTER and TC CLOUD CLIENT
In PHOENIX CONTACT TC ROUTER and TC CLOUD CLIENT prior to version 2.07.2 as well as CLOUD CLIENT 1101T-TX/TX prior to version 2.06.10 an unauthenticated remote attacker could use a reflective XSS within the license viewer page of the devices in order to execute code in the context of the user's browser. In PHOENIX CONT...
[]
null
null
4.9
null
ICSA-22-228-01
Yokogawa CENTUM Controller FCS
The Yokogawa CENTUM VP/CS 3000 Controller FCS is vulnerable to a denial-of-service attack caused by a malformed packet. This attack may stop inter-station data link block (ADL) communications.CVE-2022-33939 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is...
[]
null
null
6.5
null
ICSA-21-068-05
Siemens LOGO! 8 BM
The control logic (CL) the LOGO! 8 executes could be manipulated in a way that could cause the device executing the CL to improperly handle the manipulation and crash. After successful execution of the attack, the device needs to be manually reset.
[]
null
5.5
null
null
ICSA-23-024-02
SOCOMEC MODULYS GP (UPDATE A)
SOCOMEC MODULYS GP Netvision versions 7.20 and prior lack strong encryption for credentials on HTTP connections, which could result in threat actors obtaining sensitive information.
[]
null
null
5.7
null
ICSMA-18-137-01
Medtronic N'Vision Clinician Programmer (Update A)
The affected product does not encrypt the following sensitive information while at rest: PII - Personally Identifiable Information. Some combination of personal data that enables the unique identification of an individual. PII is defined as information that can be used to distinguish or trace an individual 's identity,...
[]
null
null
6.3
null
ICSA-20-252-02
Siemens SIMATIC S7-300 and S7-400 CPUs (Update C)
The authentication protocol between a client and a PLC via Port 102/TCP (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials.CVE-2020-15791 has been assigned to this vulnerability. A CVSS v3 base score of ...
[]
null
null
5.9
null
ICSA-18-345-01
McAfee SINAMICS PERFECT HARMONY GH180
The executable files from a hard drive solidified by MACC, of an external system, can be executed on the system that did not generate the inventory.
[]
null
null
7.1
null
ICSA-22-104-01
Delta Electronics DMARS
In four instances the affected product does not properly restrict references of XML external entities while processing specific project files, which may allow unauthorized information disclosure.CVE-2022-1331 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector strin...
[]
null
null
5.5
null
ICSA-19-134-03
Siemens LOGO! Soft Comfort (Update A)
The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. In order to exploit the vulnerability, a valid user must open a manipulated project file. No further privileges are required on the target system. The vulnerability could compromis...
[]
null
7.8
null
null
ICSA-23-306-01
Red Lion Crimson
The Crimson 3.2 Windows-based configuration tool allows users with administrative access to define new passwords for users and to download the resulting security configuration to a device. If such a password contains the percent (%) character, invalid values will be included, potentially truncating the string if a NUL ...
[]
null
null
8.8
null
ICSA-21-336-07
Hitachi Energy PCM600 Update Manager
This vulnerability exists due to a logic error in the certificate validation in the affected product. An attacker with administrator rights could exploit this vulnerability by creating software packages and signing those packages with specially crafted certificates, thereby pointing the PCM600 update server location to...
[]
null
null
6.7
null
ICSA-20-329-02
Fuji Electric V-Server Lite
The affected product is vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code.CVE-2020-25171 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-23-103-15
Mitsubishi Electric GOC35 Series
A vulnerability exists in the Ethernet communication Extension unit (GC-ENET-COM) of GOC35 series due to a signal handler race condition. If a malicious attacker sends a large number of specially crafted packets, communication errors could occur and could result in a denial-of-service condition when GC-ENET-COM is conf...
[]
null
null
7.5
null
ICSA-20-098-01
Advantech WebAccess/NMS
Multiple issues exist that allow files to be uploaded and executed on the system.CVE-2020-10621 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). There are multiple ways an unauthenticated attacker could perform SQL...
[]
null
null
8.8
null
ICSA-23-166-10
Siemens SIMATIC S7-1500 TM MFP BIOS
The iconv program in the GNU C Library (aka glibc or libc6) 2.31 and earlier, when invoked with multiple suffixes in the destination encoding (TRANSLATE or IGNORE) along with the -c option, enters an infinite loop when processing invalid multi-byte input sequences, leading to a denial of service. The iconv feature in t...
[]
null
6.6
null
null
ICSA-23-138-04
Johnson Controls OpenBlue Enterprise Manager Data Collector
Under certain circumstances, API calls to the OpenBlue Enterprise Manager Data Collector do not require authentication. Under certain circumstances, API calls to the OpenBlue Enterprise Manager Data Collector may expose sensitive information to an unauthorized user.
[]
null
null
5
null
ICSA-19-304-01
Advantech WISE-PaaS/RMM
Path traversal vulnerabilities are caused by a lack of proper validation of a user-supplied path prior to use in file operations. An attacker can leverage these vulnerabilities to remotely execute code while posing as an administrator.CVE-2019-13551 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 h...
[]
null
null
6.5
null
ICSA-21-133-03
OPC Foundation UA Products Built with .NET Framework
The affected products are vulnerable to an uncontrolled recursion, which may allow an attacker to trigger a stack overflow.CVE-2021-27432 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
null
7.5
null
ICSA-19-183-01
Schneider Electric Modicon Controllers
An attacker could create a denial-of-service condition by sending a specific crafted Modbus frame to the affected device.CVE-2019-6819 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
null
7.5
null
ICSA-17-299-01
Korenix JetNet
An attacker may gain access to hard-coded certificates and private keys allowing the attacker to perform man-in-the-middle attacks.CVE-2017-14021 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The software uses und...
[]
null
null
9.8
null
ICSA-22-207-03
Honeywell Saia Burgess PG5 PCD
The affected product uses the S-Bus protocol with authentication functions that can be controlled by the client MAC and IP. Because UDP is stateless, an attacker that can observe traffic can also spoof the MAC and IP of an authenticated client and manipulate the controller configuration.CVE-2022-30319 has been assigned...
[]
null
null
7.6
null
ICSA-22-256-02
Honeywell SoftMaster
If an attacker manages to trick a valid user into loading a malicious DLL, the attacker may be able to achieve code execution in the application 's context and permissions. CVE-2022-2333 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/U...
[]
null
null
6.2
null
ICSA-19-178-03
ABB CP635 HMI
The ABB CP635 HMI component implements hidden administrative accounts used during the provisioning phase of the HMI interface.CVE-2019-7225 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
8.8
null
ICSMA-22-298-01
AliveCor KardiaMobile
The smartphone application for the affected product is vulnerable to the publicly known Intent Manipulation exploit on Android phones. This exploit allows attackers to bypass app authentication and view or alter information in the app.CVE-2022-40703 has been assigned to this vulnerability. A CVSS v3 base score of 5.2 h...
[]
null
null
4.8
null
ICSA-22-258-04
Siemens Mendix SAML Module
Affected versions of the module insufficiently protect from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. For compatibility reasons, fix versions still contain this issue, but only when the not recommended, non default configuration ...
[]
null
7.4
null
null
ICSA-18-032-01
Fuji Electric V-Server VPR
The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution. CVE-2018-5442 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L).
[]
null
null
8.6
null
ICSA-23-131-04
Siemens SIMATIC Cloud Connect 7
The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. The affected device uses a hard-coded password to protect the diagnostic files. Thi...
[]
null
3.8
null
null
ICSA-22-069-02
Siemens SIMOTICS CONNECT 400
ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004) The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the ...
[]
null
7.5
null
null
ICSA-18-046-01
Nortek Linear eMerge E3 Series
A remote attacker may be able to execute arbitrary code on a target machine with elevated privileges. CVE-2018-5439 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
9.8
null
ICSMA-18-086-01
Philips Alice 6 Vulnerabilities (Update B)
When an actor claims to have a given identity, the software does not prove or insufficiently proves that the claim is correct. This weakness can lead to the exposure of resources or functionality to unintended actors, possibly providing attackers with sensitive information or the ability to execute arbitrary code.CVE-2...
[]
null
null
5.3
null
ICSA-18-193-01
Eaton 9000X Drive
A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution.CVE-2018-8847 has been assigned to this vulnerability. A CVSS v3 base score of 5.6 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L).
[]
null
null
5.6
null
ICSA-20-196-06
Siemens SIMATIC S7-200 SMART CPU Family
The affected devices do not properly handle large numbers of new incoming connections and could crash under certain circumstances.CVE-2020-7584 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
null
7.5
null
ICSA-23-334-01
Delta Electronics DOPSoft
The affected product is vulnerable to a stack-based buffer overflow, which may allow for arbitrary code execution if an attacker can lead a legitimate user to execute a specially crafted file.
[]
null
null
7.8
null
ICSA-23-138-03
Hitachi Energy’s MicroSCADA Pro/X SYS600 Products
The ActiveBar ActiveX control distributed in ActBar.ocx 1.0.3.8 in SYS600 product does not properly restrict the SetLayoutData method, which could allow attackers to execute arbitrary code via a crafted data argument.
[]
null
null
6.7
null
ICSA-20-224-01
Yokogawa CENTUM (Update A)
This vulnerability may allow a remote unauthenticated attacker to send tampered communication packets.CVE-2020-5608 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H). This vulnerability may allow a remote attacker to c...
[]
null
null
8.1
null
ICSA-20-098-02
GE Digital CIMPLICITY
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an attacker has access to an authenticated ...
[]
null
null
6
null
ICSA-17-194-03
Siemens SIMATIC Sm@rtClient Android App
The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a man-in-the-middle attack. This vulnerability affects only SIMATIC WinCC Sm@rtClient for Android.CVE-2017-6870 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been cal...
[]
null
null
4.6
null
ICSA-23-348-10
Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1
expat 2.1.0 and earlier does not properly handle entities expansion unless an application developer uses the XML_SetEntityDeclHandler function, which allows remote attackers to cause a denial of service (resource consumption), send HTTP requests to intranet servers, or read arbitrary files via a crafted XML document, a...
[]
null
9.8
null
null
ICSA-22-277-03
Horner Automation Cscape
The affected product does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by writing outside the memory buffer.CVE-2022-3379 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been cal...
[]
null
null
7.8
null
ICSA-20-014-02
Siemens SINEMA Server
Incorrect session validation could allow an attacker with a valid session, with low privileges, to perform firmware updates and other administrative operations on connected devices. The security vulnerability could be exploited by an attacker with network access to the affected system. An attacker must have access to a...
[]
null
9.9
null
null
ICSA-18-290-01
Omron CX-Supervisor (Update A)
When processing project files and tampering with a specific byte, memory corruption may occur within a specific object.CVE-2018-17905 has been assigned to this vulnerability. A CVSS v3 base score of 4.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L). When processing project files a...
[]
null
null
7
null
ICSA-20-070-06
Rockwell Automation MicroLogix Controllers and RSLogix 500 Software
The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller.CVE-2020-6990 has b...
[]
null
null
4
null
ICSA-22-069-04
Siemens SINEMA Mendix Forgot Password Appstore
In certain configurations of the affected product, a threat actor could use the sign up flow to hijack arbitrary user accounts. Initial passwords are generated in an insecure manner. This could allow an unauthenticated remote attacker to efficiently brute force passwords in specific situations.
[]
null
7.4
null
null
ICSA-20-224-06
Siemens Desigo CC
Affected applications are delivered with a 3rd party component (BIRT) that contains a remote code execution vulnerability if the Advanced Reporting Engine is enabled. The vulnerability could allow a remote unauthenticated attacker to execute arbitrary commands on the server with SYSTEM privileges.
[]
null
9.8
null
null
ICSA-22-181-04
Distributed Data Systems WebHMI
A user with administrative privileges in WebHMI can store a script that could impact other logged in users.CVE-2022-2254 has been assigned to this vulnerability. A CVSS v3 base score of 6.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:N/A:N). A user with administrative privileges in Web...
[]
null
null
6.2
null
ICSA-22-270-02
Hitachi Energy APM Edge
The affected product is vulnerable to a privilege escalation attack, which could allow an attacker to escalate a user account to root.CVE-2021-4034 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). The affected prod...
[]
null
null
7.8
null
ICSA-19-036-04
Siemens SIMATIC S7-1500 CPU
Specially crafted network packets sent to port 80/tcp or 443/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/tcp or 443/tcp. Successful exploitatio...
[]
null
7.5
null
null
ICSA-23-236-03
CODESYS Development System
In CODESYS Development System versions from 3.5.17.0 and prior to 3.5.19.20 a vulnerability allows for execution of binaries from the current working directory in the users' context.
[]
null
null
7.3
null
ICSA-20-175-03
ABB Device Library Wizard
The software writes sensitive system information to an unprotected file, and a low-privileged user could read confidential data from such a file. This could allow the user to take control of the productCVE-2020-8482 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vecto...
[]
null
null
7.8
null
ICSA-22-314-06
Siemens QMS Automotive
User credentials are stored in plaintext in the database. This could allow an attacker to gain access to credentials and impersonate other users.
[]
null
7.6
null
null
ICSA-23-045-01
Weintek EasyBuilder Pro cMT Series
The listed versions for Weintek EasyBuilder Pro are vulnerable to a ZipSlip attack caused by decompiling a malicious project file. This may allow an attacker to gain control of the user's computer or gain access to sensitive data. CVE-2023-0104 has been assigned to this vulnerability. A CVSS v3 base score of 9.3 has b...
[]
null
null
9.3
null
ICSA-20-196-01
Advantech iView
The affected product contains multiple SQL injection vulnerabilities that are vulnerable to the use of an attacker-controlled string in the construction of SQL queries. An attacker could extract user credentials, read or modify information, and remotely execute code.CVE-2020-14497 has been assigned to this vulnerabilit...
[]
null
null
8.2
null
ICSA-22-242-09
Omron CX-Programmer
Opening a specially crafted file could cause the affected product to fail to release its memory reference potentially resulting in arbitrary code execution.CVE-2022-2979 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A...
[]
null
null
7.8
null
ICSA-21-103-11
ICSA-21-103-11_Siemens TIM 4R-IE Devices
The ULOGTOD function in ntp.d in SNTP before 4.2.7p366 does not properly perform type conversions from a precision value to a double, which allows remote attackers to cause a denial of service (infinite loop) via a crafted NTP packet.CVE-2015-5219 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has...
[]
null
null
7.5
null
ICSA-21-287-03
Mitsubishi Electric MELSEC iQ-R Series
An unauthorized remote attacker may be able to log in to the CPU module by obtaining credentials other than password. CVE-2021-20599 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N).
[]
null
null
9.1
null
ICSA-20-182-02
Mitsubishi Electric Factory Automation Engineering Software Products
The vulnerability could allow a malicious attacker to send a file on the computer running the product to the outside.CVE-2020-5602 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). The vulnerability could allow a mali...
[]
null
null
7.5
null
ICSA-24-074-10
Siemens Siveillance Control
The affected product does not properly check the list of access groups that are assigned to an individual user. This could enable a locally logged on user to gain write privileges for objects where they only have read privileges.
[]
null
5.5
null
null
ICSA-20-252-02
Siemens SIMATIC S7-300 and S7-400 CPUs (Update C)
The authentication protocol between a client and a PLC via Port 102/TCP (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials.CVE-2020-15791 has been assigned to this vulnerability. A CVSS v3 base score of ...
[]
null
null
5.9
null
ICSA-24-226-02
Rockwell Automation AADvance Standalone OPC-DA Server
An arbitrary code execution vulnerability exists in the affected product. The log4net config file does not disable XML external entities. An arbitrary code execution vulnerability exists in the affected product. The vulnerability occurs due to a vulnerable component, the format string in log4net.
[]
null
5.3
null
null
ICSA-23-222-10
Siemens SICAM TOOLBOX II
Affected applications do not properly set permissions for product folders. This could allow an authenticated attacker with low privileges to replace DLLs and conduct a privilege escalation. The affected application's database service is executed as `NT AUTHORITY\SYSTEM`. This could allow a local attacker to execute op...
[]
null
7.8
null
null
ICSA-22-223-06
Siemens SICAM TOOLBOX II
Affected applications use a circumventable access control within a database service. This could allow an attacker to access the database.
[]
null
9.9
null
null
ICSA-20-042-07
Siemens SCALANCE X Switches (Update B)
The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website cont...
[]
null
4.2
null
null
ICSA-21-222-05
Siemens Industrial Products Intel CPUs (Update F)
Race condition in the firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access. Improper buffer restrictions in a subsystem in the Intel(R) CSME versions before 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32 and 15.0.22 m...
[]
null
5.6
null
null
ICSMA-18-144-01
BeaconMedaes TotalAlert Scroll Medical Air Systems
An attacker with network access to the integrated web server could retrieve default or user defined credentials stored and transmitted in an insecure manner.CVE-2018-7518 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/...
[]
null
null
7.5
null
ICSA-18-135-01
Advantech WebAccess
Several SQL injection vulnerabilities have been identified, which may allow an attacker to disclose sensitive information from the host.CVE-2018-7501 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). An information ...
[]
null
null
8.4
null
ICSA-21-082-03
GE Reason DR60
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components.CVE-2021-27440 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The softwa...
[]
null
null
7.8
null
ICSA-23-285-11
Siemens Mendix Forgot Password Module
Applications using the affected module are vulnerable to user enumeration due to distinguishable responses. This could allow an unauthenticated remote attacker to determine if a user is valid or not, enabling a brute force attack with valid users.
[]
null
5.3
null
null
ICSMA-21-294-01
B. Braun Infusomat Space Large Volume Pump
An improper sanitization of input vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote unauthenticated attacker to gain user-level command-line access by passing a raw external string straight through to printf statements. The attacker is required to be on the same network as the device. CVE-2021-338...
[]
null
null
6.5
null
ICSA-21-103-07
Siemens Web Server of SCALANCE X200 (Update A)
Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code. Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might le...
[]
null
9.8
null
null
ICSA-20-252-04
Siemens Spectrum Power
Insecure storage of sensitive information in the configuration files could allow the retrieval of user names. If configured in an insecure manner, the web server might be susceptible to a directory listing attack.
[]
null
3.7
null
null
ICSA-23-320-12
Siemens PNI
.NET and Visual Studio Information Disclosure Vulnerability. zlib through 1.2.12 has a heap-based buffer over-read or buffer overflow in inflate in inflate.c via a large gzip header extra field. NOTE: only applications that call inflateGetHeader are affected. Some common applications bundle the affected zlib source cod...
[]
null
7.3
null
null
ICSA-21-222-04
Siemens SINEC NMS
The affected application incorrectly neutralizes special elements when creating batch operations which could lead to command injection. An authenticated remote attacker with administrative privileges could exploit this vulnerability to execute arbitrary code on the system with system privileges.
[]
null
7.2
null
null
ICSA-21-028-01
Rockwell Automation FactoryTalk Linx and FactoryTalk Services Platform
An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected. An attacker-control...
[]
null
null
7.5
null
ICSMA-18-277-02
Change Healthcare PeerVue Web Server
This vulnerability results from improper error handling in HTTP-based communications with the server, which could allow an attacker to obtain technical information.CVE-2018-10624 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/...
[]
null
null
4.3
null
ICSA-19-106-02
WAGO Series 750-88x and 750-87x
By exploiting the undocumented service access, it is possible to change the settings of a device and access web-based management with administrator privileges. An attacker can exploit this vulnerability to lock other users out from the device or open closed network ports. It is also possible to use this service access ...
[]
null
null
9.8
null
ICSA-17-341-02
Rockwell Automation FactoryTalk Alarms and Events
An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.CVE-2017-14022 has been assigned to this vulnerability. A CVSS v3 base score ...
[]
null
null
7.5
null
ICSA-19-339-01
Thales DIS SafeNet Sentinel LDK License Manager Runtime
The affected product is vulnerable when configured as a service. This vulnerability may allow an attacker with local access to create, write, and/or delete files in system folder using symbolic links, leading to a privilege escalation. This vulnerability could also be used by an attacker to execute a malicious DLL, whi...
[]
null
null
7.3
null
ICSA-23-299-02
Centralite Pearl Thermostat
A vulnerability in Centralite Pearl Thermostat 0x04075010 allows attackers to cause a denial of service (DoS) via a crafted Zigbee message.
[]
null
7.5
null
null
ICSA-18-282-05
Siemens SIMATIC S7-1500, SIMATIC S7-1500 Software Controller and SIMATIC ET 200SP OpenController (Update A)
An attacker can cause a denial-of-service condition on the network stack by sending a large number of specially crafted packets to the PLC. The PLC will lose its ability to communicate over the network. This vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploita...
[]
null
5.3
null
null
ICSA-21-257-21
Siemens Industrial Edge
An unauthenticated attacker could change the password of any user in the system under certain circumstances and impersonate any valid user on an affected system.CVE-2021-37184 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I...
[]
null
null
9.8
null
ICSA-22-069-09
Siemens SINEC INS
SQLite 3.30.1 mishandles pExpr->y.pTab, as demonstrated by the TK_COLUMN case in sqlite3ExprCodeTarget in expr.c. Select in select.c in SQLite 3.30.1 allows a crash if a sub-select uses both DISTINCT and window functions, and also has certain ORDER BY usage. lookupName in resolve.c in SQLite 3.30.1 omits bits from the ...
[]
null
7.8
null
null
ICSA-21-194-01
Schneider Electric C-Bus Toolkit
An improper authentication issue exists and could allow an attacker to use a crafted webpage that can enable remote access to the system.CVE-2021-22784 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N).
[]
null
null
6.5
null
ICSA-23-068-03
ABB Ability Symphony Plus
An unauthorized client able to connect to the ABB S+ Operations servers (HMI network) can act as a legitimate S+ Operations client, reading any data and changing its configuration, which could result in corruption of data, unauthorized disclosure of information, unexpected operation of equipment or causing the product ...
[]
null
null
8.8
null
ICSA-22-104-11
Siemens SIMATIC Energy Manager
Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges. A DLL Hijacking vulnerability could allow a local attacker to execu...
[]
null
10
null
null
ICSA-22-349-02
Siemens SCALANCE X-200RNA Switch Devices
The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device. Specially crafted PROFINET DCP packets could cause a denial of service condition of affected ...
[]
null
6.5
null
null
ICSA-24-354-01
Hitachi Energy RTU500 series CMU
A vulnerability exists in SCI IEC 60870-5-104 and HCI IEC 60870-5-104 that affects the RTU500 series product. Specially crafted messages sent to the mentioned components are not validated properly and can result in buffer overflow and as final consequence to a reboot of an RTU500 CMU.
[]
null
5.9
null
null
ICSA-22-090-07
Rockwell Automation Studio 5000 Logix Designer
An attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code undetectable to a user.CVE-2022-1159 has been assigned to this vulnerability. A CVSS v3 base score of 7.7 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H).
[]
null
null
7.7
null
ICSA-21-068-09
Siemens Solid Edge File Parsing
Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049) When opening a specially cra...
[]
null
7.8
null
null
ICSA-21-161-01
Rockwell Automation FactoryTalk Services Platform
FactoryTalk Services Platform contains a vulnerability that may allow a remote, authenticated attacker to bypass FactoryTalk Security policies based on the computer name. If successfully exploited, this may allow an attacker to have the same privileges as if they were logged on to the client machine.CVE-2021-32960 has ...
[]
null
null
8.5
null
ICSA-18-137-02
PHOENIX CONTACT FL SWITCH 3xxx/4xxx/48xx Series
An attacker with permission to transfer configuration files to or from the switch or permission to upgrade firmware is able to execute arbitrary OS shell commands.CVE-2018-10730 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:C/C...
[]
null
null
9