60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.103.5 MSD analysis for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th and 5th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.1.103.5-1
Table 6.1.103.5-1: Harmonic and IMD analysis
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL frequency (MHz)
699
716
3550
3700
2nd harmonics ... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.103.7 MSD | Based on the co-existence studies for DC_48_n12, MSD need to be defined for IMD5 into band n12. MSD values reused from DC_28_n77,
Table 7.3B.2.3.5.1-1: MSD test points for PCell due to dual uplink operation for EN-DC in NR FR1 (two bands)
NR or E-UTRA Band / Channel bandwidth / NRB / MSD
EN-DC
Configuration
EUTRA or NR... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.104 DC_41_n3 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.104.1 Operating bands for DC | Table 6.1.104.1-1: Band combinations for EN-DC (two bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_41_n3
41
n3
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.104.2 Configuration for DC | Table 6.1.104.2-1: Inter-band EN-DC configurations (two bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA configuration
NR configuration
DC_41A_n3A
DC_41A_n3A
41A
n3A
DC_41C_n3A
DC_41A_n3A
DC_41C_n3A
CA_41C
n3A |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.104.3 Maximum output power for DC | Table 6.1.104.3-1: Maximum output power for inter-band EN-DC (two bands)
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_41A_n3A
23
+2/-3
DC_41C_n3A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.104.4 Spurious emission band UE co-existence for DC | Interference analysis for DC_41_n3 is shown in Table 6.1.104.4-1.
Table 6.1.104.4-1: Harmonics and IMD products for DC_41_n3
UE UL carriers
fx_low
fx_high
fy_low
fy_high
2nd harmonics frequency limits
2*fx_low
2*fx_high
2* fy_low
2* fy_high
3420
3570
4992
5380
3rd harmonics frequency limits
3*fx_low
3*fx_high
3* fy_low... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.104.5 MSD for DC | Reference sensitivity exceptions due to cross band isolation for DC_41_n3 reused the values of DC_3A_n41A, that areas list in Table 6.1.104.5-1 with uplink configuration specified in Table 6.1.104.5-2.
Table 6.1.104.5-1: Reference sensitivity exceptions due to cross band isolation
EN-DC configuration
UL band
DL band
MS... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.105 DC_41_n28 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.105.1 Operating bands for DC | Table 6.1.105.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_41_n28
41
n28
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.105.2 Configuration for DC | Table 6.1.105.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_41A_n28A
DC_41A_n28A
41A
n28A
DC_41C_n28A
DC_41A_n28A
DC_41C_n28A
CA_41C
n28A |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.105.3 Maximum output power for DC | Table 6.1.105.3-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_41A_n28A
23
+2/-3
DC_41C_n28A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.105.4 Spurious emission and UE co-existence for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th and 5th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.1.105.4-1
Table 6.1.105.4-1: Harmonic and IMD analysis for DC_41_n28
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL frequency (MHz)
703
748
2496
2690
... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.105.5 MSD analysis for DC | There is no additional requirement for this band combination.
6.1.105.6 ∆TIB and ∆RIB values
For DC_41_n28, the TIB,c and RIB,c values are given in the tables below.
Table 6.1.105.6-1: ΔTIB,c
Inter-band DC Configuration
E-UTRA and NR Band
ΔTIB,c [dB]
DC_41_n28
41
0.3
n28
0.3
Table 6.1.105.6-2: ΔRIB,c
Inter-band DC Co... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.106 DC_41_n78(*) | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.106.1 Operating bands for DC | Table 6.1.106.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_41_n78(*)
41
n78
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.106.2 Configuration for DC | Table 6.1.106.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_41A_n78(2A)
DC_41A_n78A
41A
CA_n78(2A)
DC_41C_n78(2A)
DC_41A_n78A
DC_41C_n78A
CA_41C
CA_n78(2A) |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.106.3 Maximum output power for DC | Table 6.1.106.3-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_41A_n78A
23
+2/-3
DC_41C_n78A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.106.4 Spurious emission band UE co-existence for DC | Refer to TR 37.863-01-01 section 6.52.3 for DC_41A_n78A. |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.106.5 MSD analysis for DC | Refer to TR 37.863-01-01 section 6.52.5 for DC_41A_n78A.
6.1.106.6 ∆TIB and ∆RIB values
Refer to TR 37.863-01-01 section 6.52.4 for DC_41A_n78A. |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.107 DC_42_n28 | 6.1.107.1 Operating bands for DC
Table 6.1.107.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_42_n28
42
n28
No
6.1.107.2 Configuration for DC
Table 6.1.107.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configurat... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.108 DC_1_n20 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.108.1 Configuration for DC | Table 6.1.108.1-1: Inter-band EN-DC configurations within FR1 (two bands)
EN-DC configuration
Uplink EN-DC configuration (NOTE 1)
Single UL allowed
DC_1A_n20A
DC_1A_n20A
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.108.2 Maximum output power for DC | Table 6.1.108.2-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_1A_n20A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.108.3 Spurious emission band UE co-existence for DC | Table 6.1.108.3-1: Spurious emissions for inter-band EN-DC of 1 LTE band + 1 NR band
E-UTRA and NR DC Configuration
Spurious emission
Protected band
Frequency range (MHz)
Maximum Level (dBm)
MBW (MHz)
NOTE
DC_1_n20
E-UTRA Band 1, 3, 7, 8, 22, 31, 32, 33, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76
FDL_low
-
FDL_high
-50... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.108.4 MSD analysis for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th and 5th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.1.108.4-1.
Table 6.1.108.4-1: Harmonic and IMD analysis
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL frequency (MHz)
1920
1980
832
862
2nd harmonics... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.109 DC_8_n20 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.109.1 Configuration for DC | Table 6.1.109.1-1: Inter-band EN-DC configurations within FR1 (two bands)
EN-DC configuration
Uplink EN-DC configuration (NOTE 1)
Single UL allowed
DC_8A_n20A
DC_8A_n20A
Yes |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.109.2 Maximum output power for DC | Table 6.1.109.2-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_8A_n20A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.109.3 Spurious emission band UE co-existence for DC | Table 6.1.109.3-1: Spurious emissions for inter-band EN-DC of 1 LTE band + 1 NR band
E-UTRA and NR DC Configuration
Spurious emission
Protected band
Frequency range (MHz)
Maximum Level (dBm)
MBW (MHz)
NOTE
DC_8_n20
E-UTRA Band 1, 31, 32, 33, 34, 40, 50, 51, 65, 67, 68, 72, 74, 75, 76
FDL_low
-
FDL_high
-50
1
E-UTRA Ban... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.109.4 MSD analysis for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th and 5th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.1.109.4-1.
Table 6.1.109.4-1: Harmonic and IMD analysis
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL frequency (MHz)
880
915
832
862
2nd harmonics f... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.110 DC_1_n71 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.110.1 Configuration for DC | Table 6.1.110.1-1: Inter-band EN-DC configurations within FR1 (two bands)
EN-DC configuration
Uplink EN-DC configuration (NOTE 1)
Single UL allowed
DC_1A_n71A
DC_1A_n71B
DC_1A_n71A
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.110.2 Maximum output power for DC | Table 6.1.110.2-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_1A_n71A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.110.3 Spurious emission band UE co-existence for DC | Table 6.1.110.3-1: Spurious emissions for inter-band EN-DC of 1 LTE band + 1 NR band
E-UTRA and NR DC Configuration
Spurious emission
Protected band
Frequency range (MHz)
Maximum Level (dBm)
MBW (MHz)
NOTE
DC_1_n71
E-UTRA Band 1, 5, 26,
FDL_low
-
FDL_high
-50
1
E-UTRA Band 41
FDL_low
-
FDL_high
-50
1
2
E-UTRA Band 71
F... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.110.4 MSD analysis for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th and 5th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.1.110.4-1.
Table 6.1.110.4-1: Harmonic and IMD analysis
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL frequency (MHz)
1920
1980
663
698
2nd harmonics... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.111 DC_3_n71 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.111.1 Configuration for DC | Table 6.1.111.1-1: Inter-band EN-DC configurations within FR1 (two bands)
EN-DC configuration
Uplink EN-DC configuration (NOTE 1)
Single UL allowed
DC_3A_n71A
DC_3A_n71B
DC_3A_n71A
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.111.2 Maximum output power for DC | Table 6.1.111.2-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_3A_n71A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.111.3 Spurious emission band UE co-existence for DC | Table 6.1.111.3-1: Spurious emissions for inter-band EN-DC of 1 LTE band + 1 NR band
E-UTRA and NR DC Configuration
Spurious emission
Protected band
Frequency range (MHz)
Maximum Level (dBm)
MBW (MHz)
NOTE
DC_3_n71
E-UTRA Band 5, 26,
FDL_low
-
FDL_high
-50
1
E-UTRA Band 41
FDL_low
-
FDL_high
-50
1
2
E-UTRA Band 3, 71
F... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.111.4 MSD analysis for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th and 5th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.1.111.4-1.
Table 6.1.111.4-1: Harmonic and IMD analysis
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL frequency (MHz)
1710
1785
663
698
2nd harmonics... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.112 DC_7_n40 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.112.1 Operating bands for DC | Table 6.1.112.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_7_n40
7
n40
Yes |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.112.2 Configuration for DC | Table 6.1.112.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
Configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_7A_n40A
DC_7A_n40A
7A
n40A |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.112.3 Maximum output power for DC | The maximum output power for the uplink EN-DC configuration for DC_7A_n40A is specified accordingly to Table 6.2.1-1 in TS 38.101-1 and similar combinations in Table 6.2B.1.3-1 in TS 38.101-3.
Table 6.1.112.3-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tol... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.112.4 Spurious emission band UE co-existence for DC | The spurious emissions requirements for DC_7A_n40A is specified accordingly to utilized E-UTRA and NR bands as well as similar combinations in Table 6.5B.3.3.2-1 in TS 38.101-3.
Table 6.1.112.4-1: Spurious emissions for inter-band EN-DC of 1 LTE band + 1 NR band
E-UTRA and NR DC Configuration
Spurious emission
Protecte... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.112.5 MSD analysis for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th, 5th , 6th and 7th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.1.112.5-1
Table 6.1.112.5-1: Harmonic and IMD analysis
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL Frequency [MHz]
2500
2570
2300
2400
2... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.112.7 MSD | Based on the co-existence study 3rd order IMD products may fall into Rx frequencies of band 7 why MSD have been defined in Table 7.3B.2.3.5.1-1.
Further, reference sensitivity exceptions (MSD) due to cross band isolation is needed for DC_7_n40. Reference sensitivity exceptions for the victim band are specified in Table... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.113 DC_12_n41 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.113.1 Operating bands for DC | Table 6.1.113.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_12_n41
12
n41
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.113.2 Configuration for DC | Table 6.113.1.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_12A_n41A
DC_12A_n41A
12A
n41A |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.113.3 Maximum output power for DC | Table 6.1.113.3-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_12A_n41A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.113.4 Spurious emission band UE co-existence for DC | Table 6.1.113.4-1: Spurious emissions for inter-band EN-DC of 1 LTE band + 1 NR band
E-UTRA and NR DC Configuration
Spurious emission
Protected band
Frequency range (MHz)
Maximum Level (dBm)
MBW (MHz)
NOTE
DC_12A_n41A
E-UTRA Band 2, 5, 13, 14, 17, 24, 25, 26, 27, 30, 48, 71, 74
FDL_low
-
FDL_high
-50
1
E-UTRA band 4, 1... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.113.5 MSD analysis for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th and 5th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.1.113.5-1
Table 6.1.113.5-1: Harmonic and IMD analysis
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL frequency (MHz)
699
716
2496
2690
2nd harmonics ... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.113.7 MSD | Co-existence studies shows that MSD does not need to be defined. |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.114 DC_28_n40 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.114.1 Operating bands for DC | Table 6.1.114.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_28_n40
28
n40
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.114.2 Configuration for DC | Table 6.1.114.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_28A_n40A
DC_28A_n40A
28A
n40A |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.114.3 Maximum output power for DC | Table 6.1.114.3-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_28A_n40A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.114.4 Spurious emission band UE co-existence for DC | Table 6.1.114.4-1: Spurious emissions for inter-band EN-DC of 1 LTE band + 1 NR band
E-UTRA and NR DC Configuration
Spurious emission
Protected band
Frequency range (MHz)
Maximum Level (dBm)
MBW (MHz)
NOTE
DC_28A_n40A
E-UTRA Band 3, 5, 7, 8, 20, 26, 27, 31, 34, 38, 41, 72
FDL_low
-
FDL_high
-50
1
E-UTRA band 22, 32, 42... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.114.5 MSD analysis for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th and 5th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.1.114.5-1
Table 6.1.114.5-1: Harmonic and IMD analysis
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL frequency (MHz)
703
748
2300
2400
2nd harmonics ... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.114.7 MSD | Co-existence studies for DC_28_n40 shows IMD5 theoretically affecting band n40 DL, but no combinations of bands 28 and n40 paired DL and UL frequencies gives IMD5.
Additional REFSENS requirements are needed to be defined in tables below in TS 38.101-3 due to 3rd harmonic DL mixing from band 28 UL affecting band n40 DL.... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.115 DC_13_n2 | 6.1.115.1 Operating bands for DC
Table 6.1.115.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_13_n2
13
n2
No
6.1.115.2 Configuration for DC
Table 6.1.115.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuratio... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.116 DC_14_n66 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.116.1 Operating bands for DC | Table 6.1.116.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_14_n66
14
n66
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.116.2 Configuration for DC | Table 6.1.116.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_14A_n66A
DC_14A_n66A
14A
n66A |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.116.3 Maximum output power for DC | Table 6.1.116.3-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_14A_n66A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.116.4 Spurious emission band UE co-existence for DC | Table 6.1.116.4-1: Spurious emissions for inter-band EN-DC of 1 LTE band + 1 NR band
E-UTRA and NR DC Configuration
Spurious emission
Protected band
Frequency range (MHz)
Maximum Level (dBm)
MBW (MHz)
NOTE
DC_14A_n66A
E-UTRA Band 2, 4, 5, 10, 12, 13, 14, 17, 24, 25, 26, 27, 29, 30, 41, 53, 66, 70, 71, 85
FDL_low
-
FDL_... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.116.5 MSD analysis for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th and 5th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.1.116.5-1
Table 6.1.116.5-1: Harmonic and IMD analysis
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL frequency (MHz)
788
798
1710
1780
2nd harmonics ... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.116.7 MSD | Co-existence studies shows that MSD does not need to be defined. |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.117 DC_14_n2 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.117.1 Operating bands for DC | Table 6.1.117.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_14_n2
14
n2
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.117.2 Configuration for DC | Table 6.1.117.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_14A_n2A
DC_14A_n2A
14A
n2A |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.117.3 Maximum output power for DC | Table 6.1.117.3-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_14A_n2A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.117.4 Spurious emission band UE co-existence for DC | Table 6.1.117.4-1: Spurious emissions for inter-band EN-DC of 1 LTE band + 1 NR band
E-UTRA and NR DC Configuration
Spurious emission
Protected band
Frequency range (MHz)
Maximum Level (dBm)
MBW (MHz)
NOTE
DC_14A_n2A
E-UTRA Band 4, 5, 10, 12, 13, 14, 17, 24, 26, 27, 29, 30, 41, 48, 53, 66, 70, 71, 85
FDL_low
-
FDL_high... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.117.5 MSD analysis for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th and 5th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.1.117.5-1
Table 6.1.117.5-1: Harmonic and IMD analysis
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL frequency (MHz)
788
798
1850
1910
2nd harmonics ... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.117.7 MSD | Co-existence studies show that MSD does not need to be defined. |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.118 DC_7_n20 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.118.1 Configuration for DC | Table 6.1.118.1-1: Inter-band EN-DC configurations within FR1 (two bands)
EN-DC configuration
Uplink EN-DC configuration (NOTE 1)
Single UL allowed
DC_7A_n20A
DC_7A_n20A
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.118.2 Maximum output power for DC | Table 6.1.118.2-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_7A_n20A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.118.3 Spurious emission band UE co-existence for DC | Table 6.1.118.3-1: Spurious emissions for inter-band EN-DC of 1 LTE band + 1 NR band
E-UTRA and NR DC Configuration
Spurious emission
Protected band
Frequency range (MHz)
Maximum Level (dBm)
MBW (MHz)
NOTE
DC_7_n20
E-UTRA Band 1, 3, 7, 8, 22, 31, 32, 33, 34, 40, 43, 50, 51, 65, 67, 68, 72, 74, 75, 76
FDL_low
-
FDL_high... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.1.118.4 MSD analysis for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th and 5th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.1.118.4-1.
Table 6.1.118.4-1: Harmonic and IMD analysis
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL frequency (MHz)
2500
2570
832
862
2nd harmonics... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2 Inter-band EN-DC including FR2 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.1 DC_2_n260 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.1.1 Operating bands for DC | Table 6.2.1.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2_n260
2
n260
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.1.2 Configuration for DC | Table 6.2.1.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A_n260(5A)
DC_2A_n260A
2A
DC_n260(5A)
DC_2A_n260(6A)
DC_2A_n260A
2A
DC_n260(6A)
DC_2A_n260(7A)
DC_2A_n260A
2A
DC_n260(7A)
DC_2A_n260(8A)
DC_2A_n26... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.1.3 Spurious emission band UE co-existence for DC | Co-existence was studied for lower order combinations DC_2A_n260A and DC_2A_n260(2A) in Rel-15, and the results are captured in 37.863-01-01. No further studies are needed for this combination. |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.1.4 MSD analysis for DC | No IMD issues are expected for DC configuration between the LTE bands below 6GHz and FR2 NR band. Furthermore, up to 7th order harmonics have no impact to Rx frequency of both LTE and NR bands.
6.2.7.5 ∆TIB and ∆RIB values
For DC_4A_n260, the TIB,c and RIB,c values are given in the tables below.
Table 6.2.7.4-1: ΔTIB... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.2 DC_2_n261 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.2.1 Operating bands for DC | Table 6.2.2.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2_n261
2
n261
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.2.2 Configuration for DC | Table 6.2.2.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A_n261A
DC_2A_n260A
2A
n261A
DC_2A_n261(2A)
DC_2A_n260A
2A
n261(2A)
DC_2A_n261(4A)
DC _2A_n261A
2A
n261(4A)
DC_2A_n261G
DC_2A_n261G
2A
n261G
DC_2A... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.3.3 Spurious emission band UE co-existence for DC | Co-existence was studied for lower order combinations DC_5_n260in Rel-15, and the results are captured in 37.863-01-01. No further studies are needed for this combination. |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.3.4 MSD analysis for DC | <Editor’s note: MSD tables shall be deleted if there are no interference. MSD values shall be specified as “N/A” if there are no MSD values required for the corresponding interference. >
6.2.3.5 ∆TIB and ∆RIB values
TIB,c and RIB,c was studied for lower order combinations DC_5_n260 in Rel-15, and the results are cap... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.3 DC_5_n260 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.3.1 Operating bands for DC | Table 6.2.3.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_5_n260
5
n260
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.3.2 Configuration for DC | Table 6.2.3.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_5A_n260(2D)
DC_5A_n260A
5A
DC_n260(2D)
DC_5A_n260(3G)
DC_5A_n260A
5A
DC_n260(3G)
DC_5A_n260(4G)
DC_5A_n260A
5A
DC_n260(4G)
DC_5A_n260(2H)
DC_5A_n26... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.4 DC_5_n261 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.4.1 Operating bands for DC | Table 6.2.4.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_66_n261
66
n261
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.4.2 Configuration for DC | Table 6.2.4.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_66A_n261(A-D)
DC_66A_n261A
66A
DC_n261(A-D)
DC_66A_n261(A-D-H)
DC_66A_n261A
66A
DC_n261(A-D-H)
DC_66A_n261(A-G)
DC_66A_n261A
66A
DC_n261(A-G)
DC_66... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.2.4.3 Spurious emission band UE co-existence for DC | Co-existence was studied for lower order combinations DC_66_n261 in Rel-15, and the results are captured in 37.863-01-01. No further studies are needed for this combination. |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.