60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.29 DC_66_n258
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.29.1 Operating bands for DC
Table 6.2.29.1-1: DC band combination of 1 LTE band + 1 NR band EN-DC band E-UTRA Band NR Band Single UL allowed DC_66_n258 66 n258 No
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.29.2 Configuration for DC
Table 6.2.29.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_66A_n258A DC_66A_n258A 66A n258A
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.30 DC_3_n257
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.30.1 Operating bands for DC
Table 6.2.30.1-1: DC band combination of 1 LTE band + 1 NR band EN-DC band E-UTRA Band NR Band Single UL allowed DC_3_n257 3 n257 No
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.30.2 Configuration for DC
Table 6.2.30.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR band DC_3C_n257A DC_3C_n257D DC_3C_n257E DC_3C_n257F DC_3C_n257G DC_3C_n257H DC_3C_n257I DC_3C_n257J DC_3C_n257K DC_3C_n257L DC_3C_n257M DC_3C_n257A 3C n257A CA_n25...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.30.3 Spurious emission band UE co-existence for DC
Table 6.2.30.3-1: Spurious emissions for inter-band EN-DC of 1 LTE band + 1 NR band E-UTRA and NR DC Configuration Spurious emission Protected band Frequency range (MHz) Maximum Level (dBm) MBW (MHz) NOTE DC_3C-n257A E-UTRA Band 1, 3, 5, 7, 8, 11, 18, 19, 21, 26, 28, 34, 39, 40, 41, 65, n79 FDL_low - FDL_high -50 1 E-U...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.30.4 MSD analysis for DC
From the coexistence analysis in TR 37.863-01-01 Table 6.36.3-1, there was no harmonic/IMD problem into own Rx of bands for DC_3C_n257 UE. 6.2.30.5 ∆TIB and ∆RIB values For DC_3C_n257, the TIB,c and RIB values are given in the tables below. Table 6.2.30.5-1: ΔTIB,c Inter-band DC Configuration E-UTRA and NR Band ΔTIB,...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.31 DC_48_n261
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.31.1 Operating bands for DC
Table 6.2.31.1-1: DC band combination of 1 LTE band + 1 NR band EN-DC band E-UTRA Band NR Band Single UL allowed DC_48_n261 48 n261 No
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.31.2 Configuration for DC
Table 6.2.31.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_48A_n261A DC_48A_n261A 48A n261A DC_48C_n261A DC_48C_n261A 48C n261A DC_48D_n261A DC_48C_n261A 48D n261A DC_48A_n261(2A) DC_48A_n261A 48A n261(2A)...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.32 DC_14_n260
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.32.1 Operating bands for DC
Table 6.2.32.1-1: DC band combination of 1 LTE band + 1 NR band EN-DC band E-UTRA Band NR Band Single UL allowed DC_14_n260 14 n260 No
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.32.2 Configuration for DC
Table 6.2.32.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_14A_n260A DC_14A_n260G DC_14A_n260H DC_14A_n260I DC_14A_n260J DC_14A_n260K DC_14A_n260L DC_14A_n260M DC_14A_n260A DC_14A_n260G DC_14A_n260H DC_14A...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.33 DC_18_n257
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.33.1 Operating bands for DC
Table 6.2.33.1-1: DC band combination of 1 LTE band + 1 NR band EN-DC band E-UTRA Band NR Band Single UL allowed DC_18_n257 18 n257 No
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.33.2 Configuration for DC
Table 6.2.33.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_18A_n257F DC_18A_n257A 18A n257F DC_18A_n257M DC_18A_n257A 18A n257M Table 6.2.33.2-2: Supported bandwidths per DC band combination of 1 LTE band ...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.33.3 Spurious emission band UE co-existence for DC
Co-existence was studied for lower order combinations DC_18_n257 in Rel-15 and the results are captured in 37.863-01-01. No further studies are needed for this combination.
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.33.4 MSD analysis for DC
MSD analysis was studied for lower order combinations DC_18_n257 in Rel-15 and the results are captured in 37.863-01-01. No further studies are needed for this combination. 6.2.33.5 ∆TIB and ∆RIB values TIB,c and RIB,c was studied for lower order combinations DC_18_n257 in Rel-15, and the results are captured in 37.8...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.34 DC_41_n257
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.34.1 Operating bands for DC
Table 6.2.34.1-1: DC band combination of 1 LTE band + 1 NR band EN-DC band E-UTRA Band NR Band Single UL allowed DC_41_n257 41 n257 No
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.34.2 Configuration for DC
Table 6.2.34.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_41A_n257F DC_41A_n257A 41A n257F DC_41A_n257M DC_41A_n257A 41A n257M DC_41C_n257F DC_41A_n257A 41C n257F DC_41C_n257M DC_41A_n257A 41C n257M Table...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.34.3 Spurious emission band UE co-existence for DC
Co-existence was studied for lower order combinations DC_41_n257 in Rel-15 and the results are captured in 37.863-01-01. No further studies are needed for this combination.
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.34.4 MSD analysis for DC
MSD analysis was studied for lower order combinations DC_41_n257 in Rel-15 and the results are captured in 37.863-01-01. No further studies are needed for this combination. 6.2.34.5 ∆TIB and ∆RIB values TIB,c and RIB,c was studied for lower order combinations DC_41_n257 in Rel-15, and the results are captured in 37.8...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.35 DC_42_n257
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.35.1 Operating bands for DC
Table 6.2.35.1-1: DC band combination of 1 LTE band + 1 NR band EN-DC band E-UTRA Band NR Band Single UL allowed DC_42_n257 42 n257 No
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.35.2 Configuration for DC
Table 6.2.35.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_42A_n257M DC_42A_n257A 42A n257M DC_42C_n257M DC_42A_n257A 42C n257M Table 6.2.35.2-2: Supported bandwidths per DC band combination of 1 LTE band ...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.35.3 Spurious emission band UE co-existence for DC
Co-existence was studied for lower order combinations DC_42_n257 in Rel-15 and the results are captured in 37.863-01-01. No further studies are needed for this combination.
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.35.4 MSD analysis for DC
MSD analysis was studied for lower order combinations DC_42_n257 in Rel-15 and the results are captured in 37.863-01-01. No further studies are needed for this combination. 6.2.35.5 ∆TIB and ∆RIB values TIB,c and RIB,c was studied for lower order combinations DC_42_n257 in Rel-15, and the results are captured in 37.8...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.36 DC_39_n257
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.36.1 Operating bands for DC
Table 6.2.36.1-1: DC band combination of 1 LTE band + 1 NR band EN-DC band E-UTRA Band NR Band Single UL allowed DC_39_n257 39 n257 No
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.36.2 Configuration for DC
Table 6.2.36.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR band DC_39A_n257A DC_39A_n257D DC_39A_n257E DC_39A_n257F DC_39A_n257G DC_39A_n257H DC_39A_n257I DC_39A_n257J DC_39A_n257K DC_39A_n257L DC_39A_n257M DC_39A_n257A 39A...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.36.3 Spurious emission band UE co-existence for DC
Table 6.2.36.3-1: Spurious emissions for inter-band EN-DC of 1 LTE band + 1 NR band UL NR CA Configuration Spurious emission Protected band Frequency range (MHz) Maximum Level (dBm) MBW (MHz) NOTE DC_39A_n257A E-UTRA Band 1, 8, 22, 26, 34, 40, 41, 42, 44, 45, 50, 51, 52, 73, 74 FDL_low - FDL_high -50 1 NR Band n77, n78...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.2.36.4 MSD analysis for DC
No IMD issues are expected for DC configuration between the LTE bands below 6GHz and FR2 NR band. Furthermore, up to 7th order harmonics have no impact to Rx frequency of both LTE and NR bands. 6.2.36.5 ∆TIB and ∆RIB values For DC_39_n257, the TIB,c and RIB values are given in the tables below. Table 6.2.36.5-1: ΔTIB...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3 Intra-band contiguous EN-DC
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.1 DC_(n)48
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.1.1 Channel bandwidths per operating band for DC
Table 6.3.1.1-1: Band combinations for intra-band contiguous EN-DC EN-DC Band Uplink Combination E-UTRA Band NR Band Single UL allowed DC_(n)48 48 n48 Yes Table 6.3.1.1-2: Supported channel bandwidths per DC configuration E-UTRA – NR configuration / Bandwidth combination set Downlink EN-DC configuration Uplink EN-DC co...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.1.2 Configuration for DC
Table 6.3.1.2-1: Intra-band contiguous EN-DC configurations EN-DC configuration Uplink EN-DC configuration E-UTRA configuration NR configuration DC_(n)48AA2 DC_(n)48AA1 48A n48A DC_(n)48CA2 DC_(n)48AA1 DC_48A_n48A1 CA_48C n48A DC_(n)48DA2 DC_(n)48AA1 DC_48A_n48A1 CA_48D n48A NOTE1: Only single switched UL is supported...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.1.3 Maximum output power for DC
Table 6.3.1.3-1: Maximum output power for Intra-band contiguous EN-DC DC configuration Power class 2 (dBm) Tolerance (dB) Power class 3 (dBm) Tolerance (dB) DC_(n)48AA1 23 +2/-3 NOTE 1: Only single switched UL is supported
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.1.4 Spurious emission band UE co-existence for DC
Note that only Single Tx Switched UL mode is supported for these combinations. No spurious emission band UE co-existence requirement is needed
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.1.5 MSD analysis for DC
Note that only Single Tx Switched UL mode is supported for these combinations. No MSD requirement is needed 6.3.1.6 ∆RIBNC values Note that the minimum requirements for these combinations only apply for non-simultaneous Tx/Rx between all carriers. No ∆RIBNC values is needed
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.1.7 MPR, AMPR requirements
Note that only Single Tx Switched UL mode is supported for these combinations. No MPR or A-MPR requirement is needed
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.2 DC_(n)12
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.2.1 Channel bandwidths per operating band for DC
Table 6.3.2.1-1: Supported channel bandwidths per DC configuration E-UTRA – NR configuration / Bandwidth combination set Downlink EN-DC configuration Uplink EN-DC configurations Component carriers in order of increasing carrier frequency Maximum aggregated bandwidth (MHz) BCS Channel bandwidths for E-UTRA carrier (MHz)...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.2.2 Configuration for DC
Table 6.3.2.2-1: Intra-band contiguous EN-DC configurations EN-DC configuration Uplink EN-DC E-UTRA configuration NR configuration Single UL allowed DC_(n)12AA DC_(n)12AA1 12A n12A Yes NOTE 1: Only single switched UL is supported
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.2.3 Maximum output power for DC
Note that only single switched UL mode is supported for this combination Table 6.3.2-1: Maximum output power for EN-DC (continuous sub-blocks) EN-DC configuration Power class 2 (dBm) Tolerance (dB) Power class 3 (dBm) Tolerance (dB) DC_(n)12AA1 23 +2/-3 NOTE 1: Only single switched UL is supported
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.2.4 Spurious emission band UE co-existence for DC
Note that only single switched UL mode is supported for this combination hence no additional spurious emission band UE co-existence requirement is needed
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.2.5 MSD analysis for DC
MSD of carrier 1 needs to be studied because UL-DL separation is smaller than in normal operation. Table below lists the MSD required for the dual connectivity configuration of single switched uplink. Table 6.3.2.5-1: MSD for the DC configuration EN-DC configuration / channel allocations /MSD EN-DC configuration E-UTRA...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.2.7 MPR, AMPR requirements
Note that only single switched UL mode is supported for this combination hence no additional MPR or A-MPR requirement is needed.
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.3 DC_(n)5
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.3.1 Channel bandwidths per operating band for DC
Table 6.3.3.1-1: Supported channel bandwidths per DC configuration E-UTRA – NR configuration / Bandwidth combination set Downlink EN-DC configuration Uplink EN-DC configurations Component carriers in order of increasing carrier frequency Maximum aggregated bandwidth (MHz) BCS Channel bandwidths for E-UTRA carrier (MHz)...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.3.2 Configuration for DC
Table 6.3.3.2-1: Intra-band contiguous EN-DC configurations EN-DC configuration Uplink EN-DC configuration E-UTRA configuration NR configuration Single UL allowed DC_(n)5AA DC_(n)5AA1 5A n5A Yes NOTE 1: Only single switched UL is supported
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.3.3 Maximum output power for DC
Note that only single switched UL mode is supported for this Table 6.3.3.3-1: Maximum output power for EN-DC (continuous sub-blocks) EN-DC configuration Power class 2 (dBm) Tolerance (dB) Power class 3 (dBm) Tolerance (dB) DC_(n)5AA1 23 +2/-3 NOTE 1: Only single switched UL is supported
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.3.4 Spurious emission band UE co-existence for DC
Note that only single switched UL mode is supported for this combination hence no additional spurious emission band UE co-existence requirement is needed
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.3.5 MSD analysis for DC
MSD of carrier 1 needs to be studied because UL-DL separation is smaller than in normal operation. Table below lists the MSD required for the dual connectivity configuration of single switched uplink. For n5+B5 of 20MHz+5MHz case, REFSENS of single RAT(n5, 20MHz) included self-UL IMD spurious. In this combination only ...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.3.7 MPR, AMPR requirements
Note that only single switched UL mode is supported for this combination hence no additional MPR or A-MPR requirement is needed.
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.4 DC_(n)38
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.4.1 Channel bandwidths per operating band for CA
Table 6.3.4.1-1: Band combinations for intra-band contiguous EN-DC EN-DC Band Uplink Combination E-UTRA Band NR Band Single UL allowed DC_(n)38 38 n38 Yes Table 6.3.4.1-2: Supported channel bandwidths per DC configuration E-UTRA – NR configuration / Bandwidth combination set Downlink EN-DC configuration Uplink EN-DC co...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.4.2 Configuration for DC
Table 6.3.4.2-1: Intra-band contiguous EN-DC configurations EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_(n)38AA5 DC_(n)38AA2 38A n38A NOTE 2: Only single switched UL is supported NOTE 5: The minimum requirements only apply for non-simultaneous Tx/Rx between all car...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.4.3 Maximum output power for DC
Table 6.3.4.3-1: Maximum output power for Intra-band contiguous EN-DC DC configuration Power class 2 (dBm) Tolerance (dB) Power class 3 (dBm) Tolerance (dB) DC_(n)38AA2 23 +2/-3 NOTE 2: Only single switched UL is supported
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.4.4 Spurious emission band UE co-existence for DC
Note that only Single Tx Switched UL mode is supported for this combination, no spurious emission band UE co-existence requirement is needed
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.4.5 MSD analysis for DC
Note that only Single Tx Switched UL mode is supported for this combination, no MSD requirement is needed
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.3.4.6 MPR, AMPR requirements
Note that only Single Tx Switched UL mode is supported for this combination, no MPR or A-MPR requirement is needed
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4 Intra-band non-contiguous EN-DC
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.1 DC_3_n3
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.1.1 Channel bandwidths per operating band for CA
Table 6.4.1.1-1: Band combinations for intra-band non-contiguous EN-DC EN-DC Band Uplink Combination E-UTRA Band NR Band Single UL allowed DC_3_n3 3 n3 Yes Table 6.4.1.1-2: Supported channel bandwidths per DC configuration E-UTRA – NR configuration / Bandwidth combination set Downlink EN-DC configuration Uplink EN-DC c...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.1.3 Maximum output power for DC
Table 6.4.1.3-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band DC configuration Power class 3 (dBm) Tolerance (dB) DC_3A_n3A 23 +2/-3
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.1.4 Spurious emission band UE co-existence for DC
Table 6.4.1.4-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band EN-DC Configuration Spurious emission for UE co-existence Protected band Frequency range (MHz) Maximum Level (dBm) MBW (MHz) NOTE DC_3_n3 E-UTRA Band 1, 5, 7, 8, 20, 26, 27, 28, 31, 32, 33, 34, 38, 39, 40, 41, 43, 44, 45, 50, 51, 65, 6...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.1.5 MSD analysis for DC
As shown in figure 6.4.1.5-1, four scenarios for potential MSD issues of DC_3_n3 were studied in R4-1901356. Note that scenario 1 is the worst case scenario where both IMD3 and IMD5 hit the DL receive blocks respectively. Figure 6.4.1.5-1: Scenarios studied for potential MSD issues for DC_3_n3 Table 6.4.1.5-1 shows the...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.1.7 MPR requirements
MPR requirements are already specified in TS 38.101-3. MPR enhancement will be covered in Rel.16 FR1 UE RF work item.
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.2 DC_66_n66
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.2.1 Channel bandwidths per operating band for CA
Table 6.4.2.1-1: Band combinations for intra-band non-contiguous EN-DC EN-DC Band Uplink Combination E-UTRA Band NR Band Single UL allowed DC_66_n66 66 n66 Yes Table 6.4.2.1-2: Supported channel bandwidths per DC configuration E-UTRA – NR configuration / Bandwidth combination set Downlink EN-DC configuration Uplink EN-...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.2.2 Configuration for DC
Table 6.4.2.2-1: Intra-band non-contiguous EN-DC configurations EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_66A_n66A DC_66A_n66A2 66A n66A NOTE2: Only single switched UL is supported
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.2.3 Maximum output power for DC
Table 6.4.2.3-1: Maximum output power for Intra-band non-contiguous EN-DC DC configuration Power class 2 (dBm) Tolerance (dB) Power class 3 (dBm) Tolerance (dB) DC_66A_n66A2 23 +2/-3 NOTE 2: Only single switched UL is supported
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.2.4 Spurious emission band UE co-existence for DC
Note that only Single Tx Switched UL mode is supported for this combination, no spurious emission band UE co-existence requirement is needed
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.2.5 MSD analysis for DC
Note that only Single Tx Switched UL mode is supported for this combination, no MSD requirement is needed 6.4.2.6 ∆RIBNC values The delta R IBNC values for intra-band non-contiguous EN-DC DC_66_n66 are shown in Table 6.4.2.6-1. Table 6.4.2.6-1: Intra-band non-contiguous EN-DC with one uplink configuration for reference...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.2.7 MPR, AMPR requirements
Note that only Single Tx Switched UL mode is supported for this combination, no MPR or A-MPR requirement is needed
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.3 DC_7_n7
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.3.1 Channel bandwidths per operating band for CA
Table 6.4.3.1-1: Band combinations for intra-band non-contiguous EN-DC EN-DC Band Uplink Combination E-UTRA Band NR Band Single UL allowed DC_7_n7 7 n7 Yes Table 6.4.3.1-2: Supported channel bandwidths per DC configuration E-UTRA – NR configuration / Bandwidth combination set Downlink EN-DC configuration Uplink EN-DC c...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.3.2 Configuration for DC
Table 6.4.3.2-1: Intra-band non-contiguous EN-DC configurations EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_7A_n7A3 DC_7A_n7A2 7A n7A NOTE 2: Only single switched UL is supported NOTE 3: Requirements in this specification apply for NR SCS of 15 kHz only
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.3.3 Maximum output power for DC
Table 6.4.3.3-1: Maximum output power for Intra-band non-contiguous EN-DC DC configuration Power class 2 (dBm) Tolerance (dB) Power class 3 (dBm) Tolerance (dB) DC_7A_n7A2 23 +2/-3 NOTE 2: Only single switched UL is supported
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.3.4 Spurious emission band UE co-existence for DC
Note that only Single Tx Switched UL mode is supported for this combination, no spurious emission band UE co-existence requirement is needed
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.3.5 MSD analysis for DC
Note that only Single Tx Switched UL mode is supported for this combination, no MSD requirement is needed 6.4.3.6 ∆RIBNC values The delta R IBNC values for intra-band non-contiguous EN-DC DC_7_n7 are same as for CA_7A-7A in TS 36.101 and are shown in table below. They are proposed to be included in 38.101-3 as a new Ta...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.3.7 MPR, AMPR requirements
Note that only Single Tx Switched UL mode is supported for this combination, no MPR or A-MPR requirement is needed
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.4 DC_48_n48
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.4.1 Channel bandwidths per operating band for DC
Table 6.4.4.1-1: Band combinations for intra-band non-contiguous EN-DC EN-DC Band Uplink Combination E-UTRA Band NR Band Single UL allowed DC_48_n48 48 n48 Yes Table 6.4.4.1-2: Supported channel bandwidths per DC configuration E-UTRA – NR configuration / Bandwidth combination set Downlink EN-DC configuration Uplink EN-...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.4.2 Configuration for DC
Table 6.4.4.2-1: Intra-band non-contiguous EN-DC configurations EN-DC configuration Uplink EN-DC configuration E-UTRA configuration NR configuration DC_48A_n48A2 DC_48A_n48A1 48A n48A DC_48A_(n)48AA2 DC_(n)48AA1 DC_48A_n48A1 CA_48A-48A n48A DC_48A-48A_n48A2 DC_48A_n48A1 CA_48A-48A n48A DC_48C_n48A2 DC_48A_n48A1 CA_48C...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.4.3 Maximum output power for DC
Table 6.4.4.3-1: Maximum output power for Intra-band non-contiguous EN-DC DC configuration Power class 2 (dBm) Tolerance (dB) Power class 3 (dBm) Tolerance (dB) DC_48A_n48A1 23 +2/-3 NOTE 1: Only single switched UL is supported
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.4.4 Spurious emission band UE co-existence for DC
Note that only Single Tx Switched UL mode is supported for these combinations. No spurious emission band UE co-existence requirement is needed.
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.4.5 MSD analysis for DC
Note that only Single Tx Switched UL mode is supported for these combinations. No MSD requirement is needed. 6.4.4.6 ∆RIBNC values Note that the minimum requirements for these combinations only apply for non-simultaneous Tx/Rx between all carriers. No ∆RIBNC values is needed.
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.4.7 MPR, AMPR requirements
Note that only Single Tx Switched UL mode is supported for these combinations. No MPR or A-MPR requirement is needed.
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.5 DC_5_n5
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.5.1 Channel bandwidths per operating band for CA
Table 6.4.5.1-1: Band combinations for intra-band non-contiguous EN-DC EN-DC Band Uplink Combination E-UTRA Band NR Band Single UL allowed DC_5_n5 5 n5 Yes Table 6.4.5.1-2: Supported channel bandwidths per DC configuration E-UTRA – NR configuration / Bandwidth combination set Downlink EN-DC configuration Uplink EN-DC c...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.5.2 Configuration for DC
Table 6.4.5.2-1: Intra-band non-contiguous EN-DC configurations EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_5A_n5A DC_5A_n5A2 5A n5A NOTE 2: Only single switched UL is supported
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.5.3 Maximum output power for DC
Table 6.4.5.3-1: Maximum output power for Intra-band non-contiguous EN-DC DC configuration Power class 2 (dBm) Tolerance (dB) Power class 3 (dBm) Tolerance (dB) DC_5A_n5A2 23 +2/-3 NOTE 2: Only single switched UL is supported
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.5.4 Spurious emission band UE co-existence for DC
Note that only Single Tx Switched UL mode is supported for this combination, no spurious emission band UE co-existence requirement is needed
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.5.5 MSD analysis for DC
Note that only Single Tx Switched UL mode is supported for this combination, no further MSD is required besides that given in section 6.4.5.6. 6.4.5.6 ∆RIBNC values The delta R IBNC values for intra-band non-contiguous EN-DC DC_5_n5 are shown in Table 6.4.5.6-1. The value is derived from values specified for E-UTRA CA_...
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.5.7 MPR, AMPR requirements
Note that only Single Tx Switched UL mode is supported for this combination, no MPR or A-MPR requirement is needed
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.6 DC_2_n2
60867663a50f38ca462c3e99d4cdca20
37.716-11-11
6.4.6.1 Channel bandwidths per operating band for CA
Table 6.4.6.1-1: Band combinations for intra-band non-contiguous EN-DC EN-DC Band Uplink Combination E-UTRA Band NR Band Single UL allowed DC_2_n2 2 n2 Yes Table 6.4.6.1-2: Supported channel bandwidths per DC configuration E-UTRA – NR configuration / Bandwidth combination set Downlink EN-DC configuration Uplink EN-DC c...