hash stringlengths 32 32 | doc_id stringlengths 5 12 | section stringlengths 5 1.47k | content stringlengths 0 6.67M |
|---|---|---|---|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.1.1.1 Operating bands for CA
| Table 5.1.1.1-1: CA band combination of band n39+n104
NR Band
Uplink (UL) band
Downlink (DL) band
Duplex mode
BS receive / UE transmit
BS transmit / UE receive
FUL_low
-
FUL_high
FDL_low
-
FDL_high
n39
1880
-
1920 MHz
1880 MHz
-
1920 MHz
TDD
n104
6425 MHz
-
7125 MHz
6425 MHz
-
7125 M... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.1.1.2 Channel bandwidths per operating band for CA
| Table 5.1.1.2-1: Supported bandwidths per CA band combination of band n39+n104
NR CA configuration
Uplink CA configuration or single uplink carrier
NR Band
Channel bandwidth (MHz)
Bandwidth combination set
CA_n39A-n104A
CA_n39A-n104A
n39
5, 10, 15, 20, 25, 30, 35, 40
0
n104
20, 30, 40, 50, 60, 70, 80, 9... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.1.1.3 UE co-existence studies for 1 band UL
| Table 5.1.1.3-1 summarizes frequency ranges where harmonics and/or harmonics mixing occur for CA_n39-n104.
Table 5.1.1.3-1 UL/DL harmonics/harmonic mixing analysis
UL/DL
n39
UL12
UL2
UL33
UL4
UL5
harmonics
fLow
1880
3760
5640
7520
9400
MSD type
n104
fLow
fHigh
1920
3840
5760
7680
9600
DL1
... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.1.1.5 REFSENS requirements
| There are no harmonic/cross band isolation co-existence problem according to UE co-existence study in section 5.1.1.3, so there is need to defined additional Refsens requirements(MSD).
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.1.1.6 OOB blocking exception requirements
| No OOB blocking issues for CA_n39-n104.
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.1.2 Specific for 2 bands UL CA
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.1.2.1 Maximum output power for inter-band CA
| Table 5.2.2.1-1: UE Power Class for uplink inter-band CA
Uplink CA Configuration
Power Class 3 (dBm)
Tolerance (dB)
CA_n39A-n104A
23
+2/-3
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.1.2.2 UE co-existence studies for 2 bands UL
| Since both n39 and n104 are TDD band, so there is no need to check the 2UL IMD for the UE-to-UE coexistence analysis.
Also there is no need to list the protected band of n39 and n104 since it can refer to the intersection of the requirements for the individual bands specified
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.1.2.3 REFSENS requirements
| There are no IMD co-existence problem according to UE co-existence study in section 5.1.2.2, so there is no need to defined additional Refsens requirements(MSD).
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.2 CA_n13-n48
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.2.1 Common for 1 band UL and 2 bands UL CA
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.2.1.1 Operating bands for CA
| Table 5.2.1.1-1: CA band combination of band n13+n48
NR Band
Uplink (UL) band
Downlink (DL) band
Duplex mode
BS receive / UE transmit
BS transmit / UE receive
FUL_low – FUL_high
FDL_low – FDL_high
n13
777 MHz - 787 MHz
746 MHz - 756 MHz
FDD
n48
3550 MHz - 3700 MHz
3550 MHz - 3700 MHz
TDD
If t... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.2.1.2 Channel bandwidths per operating band for CA
| Table 5.2.1.2-1: Supported bandwidths per CA band combination of band n13+n48
NR CA configuration
Uplink CA configuration or single uplink carrier
NR Band
Channel bandwidth (MHz)
Bandwidth combination set
CA_n13A-n48A
CA_n13A-n48A
n13
See n13 channel bandwidths in Table 5.3.5-1 of 38.101-1
4 and 5
n48
S... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.2.1.3 UE co-existence studies for 1 band UL
| Table 5.2.1.3-1 summarizes frequency ranges where harmonics and/or harmonics mixing occur for CA_n13-n48.
Table 5.2.1.3-1 UL/DL harmonics/harmonic mixing analysis
UL/DL
harmonics
n13
UL12
UL2
UL33
UL4
UL5
MSD type
fLow
777
1554
2331
3108
3885
n48
fLow
fHigh
787
1574
2361
3148
3935
DL1
3... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.2.1.5 REFSENS requirements
| There are no additional Refsens requirements based on the single band uplink analysis including the contiguous intra-band uplink carrier aggregation.
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.2.2 Specific for 2 bands UL CA
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.2.2.1 Maximum output power for inter-band CA
| Table 5.2.2.1-1: UE Power Class for uplink inter-band CA
Uplink CA Configuration
Power Class 3 (dBm)
Tolerance (dB)
CA_n13A-n48A
23
+2/-3
CA_n13A-n48B
23
+2/-3
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.2.2.2 UE co-existence studies for 2 bands UL
| Table 5.2.2.2-1 lists Band n13 + Band n48 2 bands UL CA(2CC) 2nd, 3rd, 4th and 5th order IMD for the UE-to-UE coexistence analysis.
Table 5.2.2.2-1: Band n13 and Band n48 for 2CC UL IMD products
UE UL carriers
fx_low
fx_high
fy_low
fy_high
2nd order IMD products
|fy_low – fx_high|
|fy_high – fx_low|
|fy_low +... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.2.2.3 REFSENS requirements
| There are no Refsens requirements to be added.
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.3 CA_n13-n66
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.3.1 Common for 1 band UL and 2 bands UL CA
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.3.1.1 Operating bands for CA
| Table 5.3.1.1-1: CA band combination of band n13+n66
NR Band
Uplink (UL) band
Downlink (DL) band
Duplex mode
BS receive / UE transmit
BS transmit / UE receive
FUL_low – FUL_high
FDL_low – FDL_high
n13
777 MHz - 787 MHz
746 MHz - 756 MHz
FDD
n66
1710 MHz - 1780 MHz
2110 MHz - 2200 MHz
FDD
If t... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.3.1.2 Channel bandwidths per operating band for CA
| Table 5.3.1.2-1: Supported bandwidths per CA band combination of band n13+n66
NR CA configuration
Uplink CA configuration or single uplink carrier
NR Band
Channel bandwidth (MHz)
Bandwidth combination set
CA_n13A-n66A
CA_n13A-n66A
n13
n13 channel bandwidths in Table 5.3.5-1 of 38.101-1
4 and 5
n66
n66 c... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.3.1.3 UE co-existence studies for 1 band UL
| Table 5.3.1.3-1 summarizes frequency ranges where harmonics and/or harmonics mixing occur for CA_n13-n66.
Table 5.3.1.3-1 UL/DL harmonics/harmonic mixing analysis
UL/DL
harmonics
n13
UL12
UL2
UL33
UL4
UL5
MSD type
fLow
777
1554
2331
3108
3885
n66
fLow
fHigh
787
1574
2361
3148
3935
DL1
2... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.3.1.5 REFSENS requirements
| There are no additional Refsens requirements.
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.3.2 Specific for 2 bands UL CA
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.3.2.1 Maximum output power for inter-band CA
| Table 5.3.2.1-1: UE Power Class for uplink inter-band CA
Uplink CA Configuration
Power Class 3 (dBm)
Tolerance (dB)
CA_n13A-n66A
23
+2/-3
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.3.2.2 UE co-existence studies for 2 bands UL
| Table 5.3.2.2-1 lists Band n13 + Band n66 2 bands UL CA(2CC) 2nd, 3rd, 4th and 5th order IMD for the UE-to-UE coexistence analysis.
Table 5.3.2.2-1: Band n13 and Band n66 for 2CC UL IMD products
UE UL carriers
fx_low
fx_high
fy_low
fy_high
2nd order IMD products
|fy_low – fx_high|
|fy_high – fx_low|
|fy_low +... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.3.2.3 REFSENS requirements
| Based on the analysis there are no additional Refsens requirements from the BCS increase and the intra-band downlink addition.
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.4 CA_n13-n77
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.4.1 Common for 1 band UL and 2 bands UL CA
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.4.1.1 Operating bands for CA
| Table 5.4.1.1-1: CA band combination of band n13+n77
NR Band
Uplink (UL) band
Downlink (DL) band
Duplex mode
BS receive / UE transmit
BS transmit / UE receive
FUL_low – FUL_high
FDL_low – FDL_high
n13
777 MHz - 787 MHz
746 MHz - 756 MHz
FDD
n77
3300 MHz - 4200 MHz
3300 MHz - 4200 MHz
TDD
If t... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.4.1.2 Channel bandwidths per operating band for CA
| Table 5.4.1.2-1: Supported bandwidths per CA band combination of band n13+n77
NR CA configuration
Uplink CA configuration or single uplink carrier
NR Band
Channel bandwidth (MHz)
Bandwidth combination set
CA_n13A-n77A
n778,9
CA_n13A-n77A
n13
n13 channel bandwidths in Table 5.3.5-1 of 38.101-1
4 and 5
n7... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.4.1.3 UE co-existence studies for 1 band UL
| Table 5.4.1.3-1 summarizes frequency ranges where harmonics and/or harmonics mixing occur for CA_n13-n77.
Table 5.4.1.3-1 UL/DL harmonics/harmonic mixing analysis
UL/DL
harmonics
n13
UL12
UL2
UL33
UL4
UL5
MSD type
fLow
777
1554
2331
3108
3885
n77
fLow
fHigh
787
1574
2361
3148
3935
DL1
3... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.4.1.5 REFSENS requirements
| MSD is already defined for the identified issues hence there are no additional Refsens requirements.
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.4.2 Specific for 2 bands UL CA
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.4.2.2 UE co-existence studies for 2 bands UL
| Table 5.4.2.2-1 lists Band n13 + Band n77 2 bands UL CA(2CC) 2nd, 3rd, 4th and 5th order IMD for the UE-to-UE coexistence analysis.
Table 5.4.2.2-1: Band n13 and Band n77 for 2CC UL IMD products
UE UL carriers
fx_low
fx_high
fy_low
fy_high
2nd order IMD products
|fy_low – fx_high|
|fy_high – fx_low|
|fy_low +... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.4.2.3 REFSENS requirements
| There are no additional Refsens requirements to be captured. The IMD5 case is already found in the specification and the triple beat IMD3 issue is of different band groups and therefore agreed not to be specified.
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.5 CA_n2-n13
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.5.1 Common for 1 band UL and 2 bands UL CA
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.5.1.1 Operating bands for CA
| Table 5.5.1.1-1: CA band combination of band n2+n13
NR Band
Uplink (UL) band
Downlink (DL) band
Duplex mode
BS receive / UE transmit
BS transmit / UE receive
FUL_low – FUL_high
FDL_low – FDL_high
n2
1850 MHz - 1910 MHz
1930 MHz - 1990 MHz
FDD
n13
777 MHz - 787 MHz
746 MHz - 756 MHz
FDD
If the... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.5.1.2 Channel bandwidths per operating band for CA
| Table 5.5.1.2-1: Supported bandwidths per CA band combination of band n2+n13
NR CA configuration
Uplink CA configuration or single uplink carrier
NR Band
Channel bandwidth (MHz)
Bandwidth combination set
CA_n2A-n13A
CA_n2A-n13A
n2
See n2 channel bandwidths in Table 5.3.5-1 of 38.101-1
4 and 5
n13
See n1... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.5.1.3 UE co-existence studies for 1 band UL
| Table 5.5.1.3-1 summarizes frequency ranges where harmonics and/or harmonics mixing occur for CA_n2-n13.
Table 5.5.1.3-1 UL/DL harmonics/harmonic mixing analysis
UL/DL
harmonics
n2
UL12
UL2
UL33
UL4
UL5
MSD type
fLow
1850
3700
5550
7400
9250
n13
fLow
fHigh
1910
3820
5730
7640
9550
DL1
7... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.5.1.5 REFSENS requirements
| Based on the co-existence analysis there is a harmonic mixing issue. However, based on study for potential needed MSD the conclusion is that it is not needed. Hence, no additional MSD is defined.
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.5.1.6 OOB blocking exception requirements
| No additional OOB blocking exceptions are required for this CA band combination.
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.5.2 Specific for 2 bands UL CA
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.5.2.1 Maximum output power for inter-band CA
| Table 5.5.2.1-1: UE Power Class for uplink inter-band CA
Uplink CA Configuration
Power Class 3 (dBm)
Tolerance (dB)
CA_n2A-n13A
23
+2/-3
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.5.2.2 UE co-existence studies for 2 bands UL
| Table 5.5.2.2-1 lists Band n2 + Band n13 2 bands UL CA(2CC) 2nd, 3rd, 4th and 5th order IMD for the UE-to-UE coexistence analysis.
Table 5.5.2.2-1: Band n2 and Band n13 for 2CC UL IMD products
UE UL carriers
fx_low
fx_high
fy_low
fy_high
2nd order IMD products
|fy_low – fx_high|
|fy_high – fx_low|
|fy_low + f... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.5.2.3 REFSENS requirements
| There are no requirements for Refsens, based on the IMD analysis.
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.6 CA_n5-n13
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.6.1 Common for 1 band UL and 2 bands UL CA
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.6.1.1 Operating bands for CA
| Table 5.6.1.1-1: CA band combination of band n5+n13
NR Band
Uplink (UL) band
Downlink (DL) band
Duplex mode
BS receive / UE transmit
BS transmit / UE receive
FUL_low – FUL_high
FDL_low – FDL_high
n5
824 MHz - 849 MHz
869 MHz - 894 MHz
FDD
n13
777 MHz - 787 MHz
746 MHz - 756 MHz
FDD
If the ban... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.6.1.2 Channel bandwidths per operating band for CA
| Table 5.6.1.2-1: Supported bandwidths per CA band combination of band n5+n13
NR CA configuration
Uplink CA configuration or single uplink carrier
NR Band
Channel bandwidth (MHz)
Bandwidth combination set
CA_n5B-n13A
CA_n5B
n5
CA_n5B_BSC4 and 5
4 and 5
n13
See n13 channel bandwidths in Table 5.3.5-1 of ... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.6.1.3 UE co-existence studies for 1 band UL
| Table 5.6.1.3-1 summarizes frequency ranges where harmonics and/or harmonics mixing occur for CA_n5-n13.
Table 5.6.1.3-1 UL/DL harmonics/harmonic mixing analysis
UL/DL
harmonics
n2
UL12
UL2
UL33
UL4
UL5
MSD type
fLow
1850
3700
5550
7400
9250
n13
fLow
fHigh
1910
3820
5730
7640
9550
DL1
7... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.6.1.5 REFSENS requirements
| There are no new requirements to the Refsens defined under this clause. This is treated in next clause.
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.6.2 Specific for UL CA
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.6.2.1 Maximum output power for intra-band CA
| Table 5.6.2.1-1: UE Power Class for uplink intra-band CA
Uplink CA Configuration
Power Class 3 (dBm)
Tolerance (dB)
CA_n5B
23
+2/-3
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.6.2.2 UE co-existence studies for 2 bands UL
| Table 5.6.2.2-1 lists Band n5 + Band n13 2 bands UL CA(2CC) 2nd, 3rd, 4th and 5th order IMD for the UE-to-UE coexistence analysis.
Table 5.6.2.2-1: Band n2 and Band n13 for 2CC UL IMD products
UE UL carriers
fx_low
fx_high
fy_low
fy_high
2nd order IMD products
|fy_low – fx_high|
|fy_high – fx_low|
|fy_low + f... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 5.6.2.3 REFSENS requirements
| MSD for n5B UL is already defined within TS 38.101-1 Table 7.3A.2.1-1 but not for the specific DL CA configuration This is added below. Note MSD for IMD3 is already included in the specification.
Table 5.6.2.3-1: 2DL/2UL inter-band Reference sensitivity QPSK PREFSENS and uplink/downlink configurations for PC3 CA
Band... |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 6 Dual Connectivity: Specific Band Combination Part
| |
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 6.0 DC_nX-nY
| Editor's note: The texts for NR DC can only be added together with the texts for the corresponding inter-band 2 bands UL NR CA above, which means TP to TR to include pure NR DC configuration is not allowed.
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 6.0.1 Configurations for DC_nX-nY
| Table 6.0.1-1: Inter-band NR DC configurations
NR DC
configuration
Uplink NR DC
configuration
DC_nXA-nYA
DC_nXA-nYA
DC_nX(A/B/C(2A)-nY(A/B/C(2A)
DC_nXA/B/C-nYA
|
9d167789fb60f2b6d016b76fb1d224b8 | 38.720-02-01 | 6.0.2 Maximum output power for NR-DC
| Table 6.0.2-1: UE Power Class for uplink inter-band DC
Uplink CA Configuration
Class 3 (dBm)
Tolerance (dB)
DC_nXA-nYA
23
+x/-y
DC_nXA/B/C-nYA
23
+x/-y
Annex A:
Band group definition
For the following MSD issues detection, a criterion applies in terms of band group as defined in Table A.1:
- For 2DL 1... |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 1 Scope
| The present document provides a summary of each Release 19 Feature or, whenever needed, of each significant Work Item.
The information provided in the present document is limited to an overview of each Feature, explaining briefly its purpose and the main lines of the system's behaviour to execute the Feature.
|
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 2 References
| The following documents contain provisions which, through reference in this text, constitute provisions of the present document.
- References are either specific (identified by date of publication, edition number, version number, etc.) or non‑specific.
- For a specific reference, subsequent revisions do not apply.
-... |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 3 Definitions of terms, symbols and abbreviations
| |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 3.1 Terms
| For the purposes of the present document, the terms given in TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in TR 21.905 [1].
|
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 3.2 Symbols
| Void.
3.3 Abbreviations
For the purposes of the present document, the abbreviations given in TR 21.905 [1] and the following apply.
An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in TR 21.905 [1]. Abbreviations specific to a given clause are p... |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 4 Rel-19 Executive Summary
| Rel-19 consists almost exclusively in improvements of Features introduced in previous Releases.
|
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 5 Rel-19 Energy Efficiency, Energy Saving
| 5.1 Enhancements of Network energy savings for NR
1020095
Enhancements of Network energy savings for NR
Netw_Energy_NR_enh
RP-252332
Ericsson
1021095
Core part: Enhancements of Network energy savings for NR
Netw_Energy_NR_enh-Core
R1
RP-252332
Ajit Nimbalker, Ericsson
1022095
Perf. part: Enhancements ... |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 1 Further elaboration on usage guidance of model driven service based management services. Enhance the SBMA definitions in TS 28.533 to clarify the model driven approach.
| |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 2 Enhance the "5G specifications overview" in TS 28.533 for PM TSs and NRM TSs, including
| |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 2.1 Augment the "5G specifications overview" in TS 28.533 Annex E to include the performance components.
| |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 2.2 Augment the "5G specifications overview" in TS 28.533 Annex E to include the NRM components.
| |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 3 Enhance TS 28.537 and TS 28.622 to improve the overview information for each generic management capability, to clearly describe the MnS registry and discovery capabilities and corresponding solutions for different deployment scenarios.
| |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 4 Enhance MnSInfo IOC in TS 28.622 to provide capabilities allowing MnS consumers to retrieve the MnS information for MnS instances based on specified areas (geographical area or TAI), to support the capabilities allowing MnS consumers to retrieve the management capability information of MnS instance provided by MnS pr... | |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 5 Clarify in TS 32.156 that <<SupportIOC>> instances are not used when an MnS is designed based on a model driven approach using a NRM and CRUD operations.
| |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 6 Update the ProvMnS schema in TS 28.532 to decouple the ProvMnS schema and supported feature schema.
| |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 7 Update the Annex F “Usage of CRUD operations and NRM fragments to support management capabilities in SBMA” in TS 28.533 with the overview of management capabilities and corresponding Solution Sets.
| |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 8 Add generic MnS version handling, including the specific MnS versioning in TS 28.532 and TS 28.111 for each MnS.
| |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 9 Add definition of the common notification header to TS 28.532 and reliable notification transfer in TS 28.532, TS 28.111, TS 28.622 and TS 28.623.
| |
e5b0b04a1d39a0b476bbd25bb0706ac5 | 21.919 | 10 Add input parameters for filtering on alarm conditions in TS 28.111.
|
References
List of related CRs: select "TSG Status = Approved" in:
https://portal.3gpp.org/ChangeRequests.aspx?q=1&workitem=1060006
[1] TS 28.111: "Fault Management"
[2] TS 28.532: "Management and orchestration; Generic management services"
[3] TS 28.533: "Management and orchestration; Architecture framework"... |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 1 Scope
| The present document is a technical report for power class 3 NR inter-band CA and DC configurations including inter-band CA for 3 different bands DL with x different bands UL (x=1,2) under Rel-20 time frame. The purpose is to gather the relevant background information and studies in order to address NR inter-band CA an... |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 2 References
| The following documents contain provisions which, through reference in this text, constitute provisions of the present document.
- References are either specific (identified by date of publication, edition number, version number, etc.) or non‑specific.
- For a specific reference, subsequent revisions do not apply.
-... |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 3 Definitions of terms, symbols and abbreviations
| |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 3.1 Terms
| For the purposes of the present document, the terms given in TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in TR 21.905 [1].
Carrier aggregation: Aggregation of two or more component carriers in order to support wider transm... |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 3.2 Symbols
| For the purposes of the present document, the following symbols apply:
ΔRIB,c Allowed reference sensitivity relaxation due to support for inter-band CA operation, for serving cell c
ΔTIB,c Allowed maximum configured output power relaxation due to support for inter-band CA operation, inter-band NR-DC operation and due... |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 3.3 Abbreviations
| For the purposes of the present document, the abbreviations given in TR 21.905 [1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in TR 21.905 [1].
BS Base Station
CA Carrier Aggregation
DC Dual Connectivity
DL DownLin... |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 4 Background
| |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 4.1 Introduction
| The present document is a technical report for NR inter-band CA and DC configurations including inter-band CA for 3 different bands DL with x different bands UL (x=1,2) under Rel-20 time frame. The document covers the RF requirements for each band combination specific issues (i.e. one sub-clause defined per band combin... |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 4.2 TR Maintenance
| A single company is responsible for introducing all approved TPs in the current TR, i.e. TR editor. However, it is the responsibility of the contact person of each band combination to ensure that the TPs related to the band combination have been implemented.
Editor's note: It is not recommended to bring TP to TR for t... |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 5 Three bands within FR1 Carrier Aggregation: Specific Band Combination Part
| |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 5.0 CA_nX-nY-nZ
| |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 5.0.1 Common for 1 band UL and 2 bands UL CA
| |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 5.0.1.1 Operating bands for CA
| Editor's note: For band definition, relevant rows can be copied directly from Table 5.2-1 in 38.101-1 to Table 5.x.1.1-1 below.
Table 5.0.1.1-1: CA band combination constituent bands definition
NR Band
Uplink (UL) band
Downlink (DL) band
Duplex
mode
BS receive / UE transmit
BS transmit / UE receive
FUL_l... |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 5.0.1.2 Channel bandwidths per operating band for CA
| Table 5.0.1.2-1: Supported bandwidths per CA band combination
CA operating/channel bandwidth (MHz)
NR CA configuration
Uplink CA configuration or single uplink carrier
NR Band
Channel bandwidth (MHz)
Bandwidth combination set
CA_nXA-nYA-nZA
CA_nXA-nYA
nX
Channel BWs
X
CA_nXA-nZA
nY
Channel BWs
CA_... |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 5.0.2 Specific for 2 bands UL CA
| |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 5.0.2.1 UE co-existence studies
| Editor’s Note: The tables in this section are provided to identify potential issues to be analyzed based on interference frequency range calculations, whether to specify the MSD related to collisions with the victim receiver frequency range should be based on the detailed REFSENS analysis.
|
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 5.0.2.1.1 Co-existence studies for 2UL band with 1CC per band
| Editor’s Note: Since the IMD tables have already been calculated for the different two band fallbacks, the tables below may skip the IMD calculations and refer to the relevant two band TP tables. Nonetheless, the IMD issues should be stated, and the related TPs referenced. Only one example table is provided in this tem... |
bf10857da5322f00adfa52e7746c9eaf | 38.720-03-01 | 5.0.2.1.2 Co-existence studies for 2UL band with 3CC (2CC intra-band in one band)
| Editor’s Note: Since the triple beat tables have already been calculated for the different two band fallbacks, the tables below may skip the IMD calculations and refer to the relevant two band TP tables. Nonetheless, the IMD issues should be stated, and the related TPs referenced. Only one example table is provided in ... |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.