hash stringlengths 32 32 | doc_id stringlengths 7 13 | section stringlengths 3 121 | content stringlengths 0 2.2M |
|---|---|---|---|
db5c2a2c623de7817060981e27f80453 | 103 601 | 5.4 ITS-S based CRL/DeltaCTL broadcast protocol | |
db5c2a2c623de7817060981e27f80453 | 103 601 | 5.4.1 Overview | The ITS-S based CRL/CTL broadcasting service enables an ITS-S to manage the retrieving, the transmission and the reception of the latest available trust list information, i.e. the last known CRL, Delta ECTL or DeltaCTL which shall be repeated by the CRL/CTL broadcasting service of the sending ITS-S at a pre-defined tra... |
db5c2a2c623de7817060981e27f80453 | 103 601 | 5.4.2 CRL/DeltaCTL broadcast protocol | In the case 1, the ITS-S based CRL/CTL broadcast service shall enable the continuous transmission of the latest available trust list information, i.e. the last known CRL or Delta ECTL or DeltaCTL, at a pre-defined transmission rate (frequency f1) and during a maximum time period (duration d1). It starts a timer and whe... |
db5c2a2c623de7817060981e27f80453 | 103 601 | 5.4.3 Message and version | The CRL broadcast service uses the CRL message (CertificateRevocationListMessage)as defined in ETSI TS 102 941 [2], clause A.2. The global structure of the CRL is depicted in figure 2. Figure 2: CertificateRevocationList Message The DeltaCTL broadcast service uses the ECTL message (TlmCertificateTrustListMessage) or th... |
db5c2a2c623de7817060981e27f80453 | 103 601 | 5.4.4 Protocol communication parameter | Service communication parameters are specified in clause 6.3 (CPS_003). The Port Number values of the transport protocol for the two services (CTL broadcast service and CRL broadcast service) shall be as specified in ETSI TS 103 248 [4]. |
db5c2a2c623de7817060981e27f80453 | 103 601 | 5.5 ITS-S based Full CTL broadcast protocol | |
db5c2a2c623de7817060981e27f80453 | 103 601 | 5.5.1 Overview | The ITS-S based full CTL broadcasting service enables an ITS-S to manage the retrieving, the transmission and the reception of the latest available ECTL or CTL which shall be repeated at a pre-defined transmission rate (frequency f) and during a maximum time period (duration d). If the value d is set to 0, there shall ... |
db5c2a2c623de7817060981e27f80453 | 103 601 | 5.5.2 P2P Response distribution protocol | The ITS-S based Full CTL broadcast service shall enable the transmission by an ITS-S of the ECTL message (TlmCertificateTrustListMessage) or the CTL message (RcaCertificateTrustListMessage) with the parameter 'isFullCtl' in CtlFormat set to value TRUE as defined in ETSI TS 102 941 [2], clause A.2.7. As a full CTL is a ... |
db5c2a2c623de7817060981e27f80453 | 103 601 | 5.5.3 Message and version | A peer-to-peer response message is specified to enable the distribution of the Full CTL by an ITS-S which is called Segmented CTL Response Message (SCRM). This clause provides the specification of the generic segment message structure (SegmentPDU) used by the segmentation service. An overview of the message structure i... |
db5c2a2c623de7817060981e27f80453 | 103 601 | 5.5.4 Protocol communication parameters | This service communication parameters are specified in clause 6.3 (CPS_003). A Port Number value of the transport protocol is required for the segmentation service located on top of BTP and shall be as specified in ETSI TS 103 248 [4]. SegmentPDU … segmentationTime version distributedAid fileId segmentContent ETSI ETSI... |
db5c2a2c623de7817060981e27f80453 | 103 601 | 6 Communication profiles | |
db5c2a2c623de7817060981e27f80453 | 103 601 | 6.1 CPS_001 | NOTE: The ITS-S should use Ipv6 SLAAC functionality to auto-configure its Ipv6 address. The required parameters for SLAAC (i.e. RA message) should be provided by the R-ITS-S that acts as gateway as specified in ETSI TS 103 836 [i.5], e.g. via a SAM specified in ETSI EN 302 890-1 [i.2]. Figure 6: Communication profile u... |
db5c2a2c623de7817060981e27f80453 | 103 601 | 6.2 CPS_002 | Figure 7: Communication profile using Ipv6 over "any" access layer ETSI ETSI TS 103 601 V2.1.1 (2024-03) 42 |
db5c2a2c623de7817060981e27f80453 | 103 601 | 6.3 CPS_003 | NOTE: This communication profile is specified in ETSI TS 102 941 [2], clause D.3. As shown in the figure, it is agnostic from the network access layers. The figure is only repeated here for sake of clarity. Figure 8: Communication profile using GN/BTP SHB over ITS-G5 or LTE-V2X PC5 |
db5c2a2c623de7817060981e27f80453 | 103 601 | 6.4 CPS_004 | Figure 9: Communication profile using GN/BTP GUC or GBC over ITS-G5 or LTE-V2X PC5 ETSI ETSI TS 103 601 V2.1.1 (2024-03) 43 Annex A (normative): PICS pro forma A.1 The right to copy Notwithstanding the provisions of the copyright clause related to the text of the present document, ETSI grants that users of the present ... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 1 Scope | The present document details the technical specifications for the Smart Secure Platform (SSP) in a discrete hardware non removable component, also known as eSSP. The present document defines specific attributes on top of the generic SSP specified in ETSI TS 103 666-1 [1] for eSSP Type 1, including the external interfac... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 2 References | |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 2.1 Normative references | References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. • In the case of a reference... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 2.2 Informative references | References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. • In the case of a reference... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 3 Definition of terms, symbols and abbreviations | |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 3.1 Terms | For the purposes of the present document, the terms given in ETSI TS 103 666-1 [1], clause 3.1 apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 3.2 Symbols | Void. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 3.3 Abbreviations | For the purposes of the present document, the abbreviations given in ETSI TS 103 666-1 [1], clause 3.3 and the following apply: eSSP embedded SSP ETSI ETSI TS 103 666-3 V16.0.0 (2020-07) 9 Release 16 |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 4 Introduction | |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 4.1 Background | The present document defines an embedded secure element which allows different combinations of form factors, physical and electrical interfaces, transport layers, file system and security requirements based on the targeted use-case. This secure element is called embedded Smart Secure Platform (eSSP) Type 1 and is a spe... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 4.2 Document layout | The present document specifies: • the definition and overview of an eSSP Type 1; • the eSSP Type 1 architecture and the possible transport protocol(s) used between the terminal and the eSSP Type 1; • the eSSP Type 1 features and characteristics, including security requirements; • the eSSP Type 1 possible physical inter... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 4.3 External references | This document contains several references to other specifications, therefore required replacements as defined in ETSI TS 103 666-1 [1] in clause 4.3 shall apply. As the present document targets the eSSP Type 1 class, word "SSP" from ETSI TS 103 666-1 [1] shall be replaced with "eSSP Type 1" as needed. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 4.4 ASN.1 syntax | |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 4.4.1 Introduction | The ASN.1 syntax defined in ETSI TS 103 666-1 [1], clause 4.4.1 shall apply. The ASN.1 code defined in this document are provided in addition to definitions of ETSI TS 103 666-1 [1]. The complete ASN.1 code is provided for reference in annex A. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 4.4.2 Start of ASN.1 | -- ASN1START ESSPDefinitions { itu-t (0) identified-organization (4) etsi (0) smart-secure-platform (3666) part3 (3) } DEFINITIONS AUTOMATIC TAGS EXTENSIBILITY IMPLIED ::= BEGIN IMPORTS /* Basic types */ maxUInt32, UInt32, /* Common types */ UUID, URI, Certificates, VersionType FROM SSPDefinitions { itu-t (0) identifie... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 5 eSSP Type 1 architecture | |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 5.1 Overview | The eSSP Type 1 is a specific SSP class which is a non-removable discrete hardware component. The type and number of physical interface and the form factor depend of the implementation of the eSSP Type 1. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 5.2 Software architecture | The eSSP Type 1 shall use the software architecture "SSP software running directly on SSP hardware platform" described in ETSI TS 103 666-1 [1], clause 5.2. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 5.3 Hardware architecture | In addition to eSSP Type 1 example description in ETSI TS 103 666-1 [1], clause 5.3, an eSSP Type 1 has physical interface(s). |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 5.4 Protocol stacks | As described in ETSI TS 103 666-1 [1], clause 5.4, the eSSP Type 1 may have multiple physical interfaces. The eSSP Type 1 shall support at least one physical interface that supports the SSP Common Layer (SCL) implementation, as described in ETSI TS 103 666-1 [1], clause 8. An eSSP Type 1 may implement an ISO/IEC 7816-3... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 5.5 Execution frameworks | The eSSP Type 1 should support an execution framework as defined for the UICC according to ETSI TS 102 241 [4] based on the Java Card™ Platform [5], [6] and [7]. If the eSSP Type 1 supports the contactless interface defined in ETSI TS 102 613 [8] and the protocol defined in ETSI TS 102 622 [3], the eSSP Type 1 shall su... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6 eSSP Type 1 characteristics | |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.1 Form factors | The eSSP Type 1 form factor may comply with ETSI TS 102 671 [10] with the exception of MFF1. ETSI ETSI TS 103 666-3 V16.0.0 (2020-07) 11 Release 16 |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.2 Power | 6.2.1 Power mode The power modes defined in ETSI TS 103 666-1 [1], clause 6.2.1 shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.2.2 Power sources | |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.2.2.1 Types of power sources | The type of power source defined in ETSI TS 103 666-1 [1], clause 6.2.2.1 shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.2.2.2 Power source of type Interface | The power source of type interface defined in ETSI TS 103 666-1 [1], clause 6.2.2.2 shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.2.2.3 Power source of type Independent | The power source of type independent defined in ETSI TS 103 666-1 [1], clause 6.2.2.3 shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.2.3 Power consumption | The power consumption defined in ETSI TS 103 666-1 [1], clause 6.2.3 shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.3 Clock | The eSSP Type 1 shall support a clock as defined in ETSI TS 103 666-1 [1], clause 6.3. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.4 SSP initialization | |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.4.1 SSP interface session | The eSSP Type 1 interface session defined in ETSI TS 103 666-1 [1], clause 6.4.1 shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.4.2 Capability exchange | |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.4.2.1 Overall description | The capability exchange procedure is used to inform the eSSP Type 1 of the capabilities of the terminal and for the terminal to retrieve the capabilities of the eSSP Type 1. The capability exchange for eSSP Type 1 supporting SCL as defined in ETSI TS 103 666-1 [1], clause 6.4.2.3. shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.4.2.2 Capabilities of the terminal | The data field sent by the terminal to the eSSP Type 1 during the capability exchange procedure shall contain the data structure defined in ETSI TS 103 666-1 [1], clause 6.4.2.4, with the following modifications: • aPhysicalInterfaces in the TerminalCapability should be present. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.4.2.3 Capabilities of the eSSP Type 1 | The data field sent by the eSSP Type 1 to the terminal contains the data structure defined in ETSI TS 103 666-1 [1],clause 6.4.2.5, with the following modification: ETSI ETSI TS 103 666-3 V16.0.0 (2020-07) 12 Release 16 • SSPClass field shall have the eSSPClass-Embedded-Type1 (1) value. • aPhysicalInterfaces and aSspEx... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.5 Storage | The storage capabilities of the eSSP Type 1 interface defined in ETSI TS 103 666-1 [1], clause 6.5 shall apply with the following modifications: • An eSSP Type 1 shall use only its own dedicated internal non-volatile memory (NVM) for code and data. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.6 Data management | |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.6.1 UICC file system | The eSSP Type 1 may support the UICC file system as specified in ETSI TS 102 221 [2], clauses 8.1, 8.2 and 8.3, and the associated security features described in ETSI TS 102 221 [2], clause 9. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.6.2 eSSP Type 1 file system | The eSSP Type 1 may support the SSP file system defined in ETSI TS 103 666-1 [1], clause 6.6.2 and its sub-clauses. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.7 eSSP Type 1 identification | The eSSP Type 1 shall be identified with an identifier based on the definition in ETSI TS 103 666-2 [16], clause 7.5 with the following exceptions: • SSP Type identifies the type of eSSP Type 1 and is coded as follows: Base-32 character Value Description E '00100' Embedded SSP Type 1 (eSSP Type 1) • SSP Manufacturer id... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.8 Runtime environment | |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.8.1 CAT Runtime Environment | If the eSSP Type 1 support the CAT Runtime Environment as specified in ETSI TS 102 241 [4] the provisions defined in ETSI TS 103 666-1 [1] clause 6.8.1 for eSSP Type 1 supporting SCL shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.9 eSSP Type 1 suspension | If the eSSP Type 1 support the suspension mechanism, the provisions defined in ETSI TS 103 666-1 [1], clause 6.9 shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.10 eSSP Type 1 Applications | The eSSP Type 1 support for eSSP Type 1 applications is defined in ETSI TS 103 666-1 [1], clause 6.10 and its sub-clauses. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.11 eSSP Type 1 security | |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.11.1 eSSP Type 1 security architecture | The eSSP Type 1 security architecture overview and requirement provided in ETSI TS 103 666-1 [1], clause 6.11.1 shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.11.2 Mandatory requirements | The eSSP Type 1 mandatory security requirement provided in ETSI TS 103 666-1 [1], clause 6.11.2 and its sub-clauses shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.11.3 Optional requirements | The eSSP Type 1 optional security requirement provided in ETSI TS 103 666-1 [1], clause 6.11.3 and its sub-clauses may apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.11.4 Security certification | The eSSP Type 1 may accommodate different security features and may meet different security levels depending on the targeted applications. The different security levels are evaluated by independent evaluation labs based on industry specific Protection Profiles. The eSSP Type 1 shall be common criteria certified at leas... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.12 User interface | The eSSP Type 1 may support an web-based user interface, in that case clause 6.12 and its sub-clauses in ETSI TS 103 666-1 [1] shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 6.13 Accessor authentication service | The eSSP Type 1 shall support the accessor authentication service described in ETSI TS 103 666-1 [1], clause 6.13 and its sub-clauses. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 7 Physical interfaces | |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 7.1 Overview | The eSSP Type 1 physical interface description clause 7.1 and its sub-clauses in ETSI TS 103 666-1 [1] shall apply, with the following additions: • At least one physical interface shall be used to convey SCL. If the eSSP Type 1 has multiple interfaces that support SCL, theses interfaces should be able to work concurren... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 7.2 Reset | The eSSP Type 1 description clause 7.2 and its sub-clauses in ETSI TS 103 666-1 [1] shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 7.3 ISO 7816 interface | The eSSP Type 1 may support an interface ISO/IEC 7816-3 [11], in that case clause 7.3 and its sub-clauses in ETSI TS 103 666-1 [1] shall apply, with the following additions: • the eSSP Type 1 should support the T=0 protocol. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 7.4 SPI interface | The eSSP Type 1 may support an SPI interface, in that case clause 7.4 and its sub-clauses in ETSI TS 103 666-1 [1] shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 7.5 I2C interface | The eSSP Type 1 may support an I2C interface, in that case clause 7.5 and its sub-clauses in ETSI TS 103 666-1 [1] shall apply. ETSI ETSI TS 103 666-3 V16.0.0 (2020-07) 15 Release 16 |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 7.6 SWP interface | The eSSP Type 1 may support an SWP interface, in that case clause 7.6 and its sub-clauses in ETSI TS 103 666-1 [1] shall apply. In addition: • the eSSP Type 1 should support extended resume time; • the terminal should deactivate the SWP line only prior to a global eSSP Type 1 deactivation; • the values for power mode g... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 7.7 USB interface | The eSSP Type 1 may support an USB interface, in that case clause 7.7 and its sub-clauses in ETSI TS 103 666-1 [1] shall apply. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 8 SSP Common Layer (SCL) | |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 8.1 introduction | The eSSP Type 1 shall support the SCL protocol, therefore the provisions defined in ETSI TS 103 666-1 [1] clause 8 and its sub-clauses shall apply, with the exception listed below: • The SCL network controller host and SCL router need not to share the same security perimeter of the eSSP Type 1, i.e. the security perime... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 8.2 eSSP Type 1 with only one SCL interface | If the eSSP Type 1 has only one SCL interface, this interface should convey packets to multiple SCL hosts outside the SSP host domain, as illustrated in clause B.1. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 8.3 eSSP Type 1 with multiple SCL interfaces | If the eSSP Type 1 has multiples SCL interfaces, all these interfaces should belong to the same SCL network. Furthermore, the eSSP Type 1 should implement the SCL router and SCL network controller host, as illustrated in clause B.2. SCL hosts of an host domain should be accessible only through one SCL interface. The co... |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 9 Secure SCL | The eSSP Type 1 should support, on top of the secure SCL protocol as defined in ETSI TS 103 666-1 [1], clause 9 and its sub-clauses. |
4710d03ec77e74687963348b46830aa4 | 103 666-3 | 10 Communication layers above SCL | The eSSP Type 1 may support, on top of the SCL protocol, any protocol defined in ETSI TS 103 666-1 [1] clause 10 and its sub-clauses, e.g. APDU protocol, file system protocol, TCP control protocol support, UDP control protocol support, CRON service, contactless communications, CAT over SCL. ETSI ETSI TS 103 666-3 V16.0... |
edc47863997555e38dbe7042d128ab8e | 103 600 | 1 Scope | The present document contains specification of interoperability test descriptions to validate implementations of ETSI TS 103 097 [1], ETSI TS 102 941 [3] and ETSI TS 102 940 [i.1]. |
edc47863997555e38dbe7042d128ab8e | 103 600 | 2 References | |
edc47863997555e38dbe7042d128ab8e | 103 600 | 2.1 Normative references | References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. Referenced documents which a... |
edc47863997555e38dbe7042d128ab8e | 103 600 | 2.2 Informative references | References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. NOTE: While any hyperlinks i... |
edc47863997555e38dbe7042d128ab8e | 103 600 | 3 Definition of terms, symbols and abbreviations | |
edc47863997555e38dbe7042d128ab8e | 103 600 | 3.1 Terms | For the purposes of the present document, the terms given in ETSI TS 103 097 [1], ETSI TS 102 940 [i.1], ETSI TS 102 941 [3], ISO/IEC 15408-2 [i.2] and the following apply: current CA: CA possessing the certificate containing in the trusted chain for at least one of certificate currently used by the SUT foreign CA: any... |
edc47863997555e38dbe7042d128ab8e | 103 600 | 3.2 Symbols | For the purposes of the present document, the symbols given in ETSI TS 103 097 [1], ETSI TS 102 940 [i.1], ETSI TS 102 941 [3], ISO/IEC 15408-2 [i.2] apply. |
edc47863997555e38dbe7042d128ab8e | 103 600 | 3.3 Abbreviations | For the purposes of the present document, the abbreviations given in ETSI TS 103 097 [1], ETSI TS 102 941 [3], ETSI TS 102 940 [i.1], ISO/IEC 15408-2 [i.2] apply. |
edc47863997555e38dbe7042d128ab8e | 103 600 | 4 Requirements and configuration | |
edc47863997555e38dbe7042d128ab8e | 103 600 | 4.1 Requirements | |
edc47863997555e38dbe7042d128ab8e | 103 600 | 4.1.1 Overview | Clauses 4.1.2, 4.1.3 and 4.1.4 define mandatory and optional requirements for the implementation of ITS station, PKI or TLM. All EUT shall support mandatory requirements. Essential optional requirements defined in clause 5 and in use-case descriptions. NOTE: Interoperability testing between two IUTs cover mandatory req... |
edc47863997555e38dbe7042d128ab8e | 103 600 | 4.1.2 ITS stations | Mandatory requirements: • The ITS-S shall support data communication using security mechanisms described in ETSI TS 103 097 [1] and PKI communication described in ETSI TS 102 941 [3]. • The ITS-S shall support algorithms and key length according to the Certificate Policy [4]. • In order to participate in secured commun... |
edc47863997555e38dbe7042d128ab8e | 103 600 | 4.1.3 PKI | Mandatory requirements: • The CAs (RCA, EA, AA) shall support algorithms and key length according to the Certificate Policy [4]. Optional requirements: PICS Description PICS_PKI_ITSS_NO_PRIVACY_REQ ITS-S supports optional privacy requirement, e.g. RSU. The present PICS does not apply to most vehicular ITS-S. PICS_PKI_I... |
edc47863997555e38dbe7042d128ab8e | 103 600 | 4.1.4 TLM | Mandatory requirements: • The TLM shall support algorithms and key length according to the Certificate Policy [4]. |
edc47863997555e38dbe7042d128ab8e | 103 600 | 4.2 Configurations | |
edc47863997555e38dbe7042d128ab8e | 103 600 | 4.2.1 CFG_SEC - ITS-S secured communication | This clause describes the configuration used to execute secure communication test scenarios. The configuration contains the following entities: • Sender - The ITS-S playing a sender role. • Receiver - The ITS-S playing a receiver role. • Sender AA - The authorization authority that issued the sender's AT. ETSI ETSI TS ... |
edc47863997555e38dbe7042d128ab8e | 103 600 | 4.2.2 CFG_PKI - PKI communication | This clause describes the configuration used to execute PKI communication scenarios. The configuration contains the following entities: • ITS-S - the ITS station triggering the scenario execution. • EA - enrolment authority by which the ITS-S is enrolled. • AA - authorization authority by which the ITS-S is authorized.... |
edc47863997555e38dbe7042d128ab8e | 103 600 | 5 Requirements to be tested | |
edc47863997555e38dbe7042d128ab8e | 103 600 | 5.1 Overview | The clauses below collect and enumerate the requirements that can be tested with the present interoperability test specification. |